Loading...
HomeMy WebLinkAboutWQ0040222_Application (FTSE)_20180815July 26, 2018 JUL 3 0 2018 ±i 71 d-.�P , rations dd Mr. Tim Heim, PE NCDEQ/DWR Water Quality Permitting 2090 US Highway 70 Swannanoa, NC 28778 828-296-4500 Subject: Sewer Extension Permit Application NCDOT TIP No: U-5840 Hendersonville, NC Dear Mr. Heim, 6rvmno, L10 I 'pg'(01 p1 0 0o0 �vv 9W STV has completed the design of the above subjected project and attached please find the following documents: 1. Cover Letter 2. Check in the Amount of $480.00 3. SSEA 04-16 Sewer System Extension Application Instructions marked 4. SSEA 04-16 Sewer System Extension Application — original signed plus one copy 5. Flow Tracking/Acceptance Form (FTSE 04-16) 6. Two (2) Sets of signed and sealed plans 7. Engineering Calculations for Capacity signed and sealed 8. Site Maps (street level and USGS map). 9. Cane Creek Water and Sewer District — Sewer Service Requests 10. Special Provisions Please refer to sheet no. UC -3 of the attached plans, attached standard special provision, and NCDOT's "Standard Specifications for Roads and Structures", dated January 2018, for specifications of the project. Should you have any questions or need additional documents or information, please feel free to contact me at (704) 816-2547 or by email at andrew.vane�cgstvinc,com. Sincerely, STV ENGINEERS INC. Andrew S. Vane, PE Sr. Project Manager 900 WEST TRADE STREET, SUITE 715 AN EMPLOYEE -OWNED COMPANY PROVIDING QUALITY SERVICE SINCE 1912 I CHARLOTTE, NORTH CAROLINA 28202-1144 (704) 372-1885 FAX: (]04) 372-3393 61, STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER GOVERNOR DATE: April 12, 2018 ID#: U-5840 COUNTY:HENDERSON WBS: 50231.2.1 CE'C FEE" QWIt APR 17 2018 STV MC. Charlotte, NG JAMES H. TROGDON, III SECRETARY DESCRIPTION: SR 1547 (OLD AIRPORT RD) FROM US 25 (HENDERSON-VILLE RD) TO: DREW VANE FROM: FRANKIE J DILLS, Jr., 0-4SI-4- DIVISION RIGHT OF WAY AGENT SUBJECT: SEWER SERVICE REQUESTS Drew as per our phone conversation I have attached the original forms signed by parcel 16 Jerry Souther and Parcel 10 David Puckett for their sewer service request. FJD,Jr:sa Mailing Address: NC DEPARTMENT OF TRANSPORTATION RIGHT OF WAY DIVISION 14 1594 E MAIN ST SYLVA, NC 28779 Telephone: (928) 586-4040 Fax: (828) 586-6253 Customer Service: 1-877-368-4968 Website.: w Yncdorgov e�l 4 JUL 3 0 2018 Location: 1594 EAST MAIN STREET SYLVA, NC 28779 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 — SEWER SYSTEM EXTENSION APPLICATION SSEA 04-16 & SUPPORTING DOCUMENTATION Application Number: 222 1. APPLICANT INFORMATION: I . Applicant's name: Cane Creek Water & Sewer District 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State N Municipal 3. Signature authority's name: Marcus Jones per 15A NCAC 02T 0106(b) Title: Director of Engineering 4. Applicant's mailing address: I Historic Courthouse Square, Suite 6 City: Hendersonville State: NC Zip: 28792- 5. Applicant's contact information: Phone number: (828) 694-6526 Email Address: maiones .hendersoncountvnc org DWR) ❑ Privately -Owned Public Utility ❑ County 11. PROJECT INFORMATION: I. Project name: NCDOT TIP Project: U-5840 2. Application/Project status: N Proposed (New Permit) ❑ Existing Permit/Project 3. If a modification, provide the existing permit number: WQ00 and issued date: 4. If new construction but partof a master plan, provide the existing permit number: W000 5. County where project is located: Henderson 6. Approximate Coordinates (Decimal Degrees): Latitude: 35.43680 Longitude: -82.4930o 111. CONSULTANT INFORMATION: I. Professional Engineer: Andrew S. Vane License Number: 025221 Firm: STV Engineers Mailing address: 900 West Tade Street, Suite 715 City: Charlotte State: NC Zip: 28202-1144 Phone number: (704) 412-0783 Email Address: andrew.vane(&,stvinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Water Reclamation Facility Permit Number: NCO02491 t Owner Name: MSD Buncombe County V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQCS00004 System Wide Collection System Permit Number(s)> Owner Name(s): MSD of Buncombe County Collection System 2 JUL 3 0 2018 P FORM: SSEA 04-16 Page 1 of 6 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been submitted? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operalional1Aereencm (FORM: DEV) been submitted? [:]Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational A reement FORM: HOA been submitted? []Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Is/was an Environmental Assessment required under 15A NCAC 01 C? ❑ Yes ® No If yes, submit the appropriate final environmental document (FONSI, ROD, etc.) 6. Nature of wastewater: 100%Domestic/Commercial %Otherwaste —specify:. % Industrial (See 15A NCAC 02T.0 101M) 7. Wastewater generated by project: 1080 GPD (per 15A NCAC 02T .0114) Has a flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ❑ No If yes, provide a copy of Row reduction approval letter 8. Summarize wastewater generated by project: Establishment Type Daily Design Flow'.' No. of Units Flow Dwellings 360 gal/day 3 1080 D gal/ 0 GPD gal/ 0 GPD gal/ 0 GPD gal/ 0 GPD gal/ 0 GPD Total 1080 6PD a See 15A NCAC 02T 0114(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T.0 I 14(c), design flow rates for establishments not identified below shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. FORM: SSEA 04-16 Page 2 of 6 VII. GRAVITY SEWER DESIGN CRITERIA - 15A NCAC 02T.0305: I. Summarize Gravity Sewer to be permitted: Size (inches) Length (feet) Material 8 418 DIP PC350 6 35 DIP PC350 4 26 DIP PC350 SVC? VIII. PUMP STATION DESIGN CRITERIA -02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude; - ' 3. What is the nearest 100 -year flood elevation to the facility? feet mean sea level. Source: Is any of the proposed project located within the 100 -year flood plain? ❑ Yes ❑ No 4. If Yes, are the following items provided per 15A NCAC 02T .0305(e): Water -tight seals on all station hatches and manholes; and Control panels vents extend two feet above the 100 -year flood plain elevation? ❑ Yes ❑ No ❑ N/A If No, what measures are being taken to protect them against flooding? _ 5. Finish grade elevation of the pump station: _ 6. Design flow of the pump station: millions gallons per day (firm capacity) 7. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 8. Number of pumps provided: _ 9. Number of pump cycles at average daily flow: _ cycles per hour 10. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: SSEA 04-16 Page 3 of 6 VIII. PUMP STATION DESIGN CRITERIA (continued) 11. Summarize the pump station design elements: Design Element Plan Sheet Reference Specification Reference Power Reliability Source and Associated Elements Pump -Off Elevation feet Screened Wet Well Vent Check Valves, Gate Valves, etc. Control Panel Restricted Access Elements (Fence, Wet Well Lock, etc) Audible and Visual Alarms Telemetry/SCADA Level Controls Weatherproof Sign with Required Information Air Relief Valves 12. Summarize the force main to be permitted: Size (inches) Length (feet) Material High Discharge Elevation (feet) Elevation (feet) Pump -Off Elevation feet 13. Air release valve station locations per 15A NCAC 02T .0305(1): Air Release Valve # Station Plan Sheet Reference FORM: SSEA 04.16 Page 4 of 6 IX. SETBACKS & SEPARATIONS —(028.0200 & 15A NCAC 02T.0305(f): 1. Does the project comply with all separations found in I5A NCAC 02T.0305(f) & (e) ® Yes ❑ No > 15A NCAC 02T.0305(f) contains minimum separations that shal I he nrnvided fnr sewer systems-. Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS -I waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS -I or WS -V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item 1X.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth rade (vertical) 36 inches > 15A NCAC 02T.0305(a) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboaae ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/cerli£cations)? ® Yes ❑ No Per 15A NCAC 02T.O105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer' means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or eteriorates the sewer. El Yes ® No > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: SSEA 04-16 Page 5 of 6 IX. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria(latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, Andrew S. Vane attest that this application for (Professional Engineer's name from Application Item 111. 1.) Cane Creek Water & Sewer District name from Application Item 11. has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with this application package and its instructions, as well as all applicable regulations and statutes. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and havejurged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per ISA NCAC 02T.0106(b): Marcus Jones, Director of name Cane Creek Water & Sewer District (Facility name from Application Item II.1.) that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that any discharge of wastewater from this noir-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any a plication package shall be guilty of a Class 2 misdemeanor, which may includes fine not to%exc d $10,000 as well ase nl penalties up to $25,000 per violation. ture:2/_� Date: //,/A FORM: SSEA 04-16 Page 6 of 6 NCDOT TIP Project U-5840 Fast— Track Rec'd July 30, 2018 Henderson County r_ :FID(U`ICP9'4`oOCUMENTd.P.PIR4EO€UN"y.F1EMIP)B �RovgIPTEtYe66A�EF tiz �,fi III. Cc lificatit) n Statement: 1 LXGt/�fnl��� certify to the best of my kno\\Icdge that the addition ul'lhe volume of \mste+\'ater to be permitted in this project has been evaluated alone the route to the receiving n•asle\s;ucr Irrnmcnt Ihcility and dint the 11oa from (Ills project isnot anticipated to cause nn} capaciq related sanitary sc\rer ovarllu\cs or urerburden unp do\cnsu Cam pump stmioo en route to the Neck aQ Ircaunent plant under normal circum sources, given (he implementation of the planned improvements idcntihetl in the plam\ing assessment \\'hell` applicable. ThIs:II1.I \'Slti has bCCn pCl'Inl'nte`d in accordance x0th local established policies and procedures using the best ,I% tillable daut.'Ihis certif icalion applies to (hose imams listed AMC C in Sections 1 laid 11 plus all attached planning assessment addctidums Ion' which I am tltc responsible pa rly. Signature 01 this lurm indicates acceptm\ce of this wasle\+•aler Ilo\v. Page 2 o1' 2 P"I'SE 04-16 State of North,Carolina Department of Environment Quality 111111111M fillllllll�WQQQ4Q222 Division of Water Resources Division Of Water Re50UICE5 DWARN& Tracking/Acceptance for Sewer Extension Applications (FTSE -04-16) FntityApplicant Manic: CANE CREEK SEI ERDISTItICT Projccl Name for which flow is being requested: 2018154 - NCDOT/OLD AIRPORT ROAD-CCWSD V00076CC ,110re than one FTSE nigr he inquired (vn.ringle prni"Ct if the owner n/'(he II'11 TP is mmol rraprui.vihle Jin' u1l tnimpstaimns ulnng the mune n% rhe proposedira.ste+ratem_/lou'. I. Complete this section only if you are the owner of the wastewater ocauncnl plant. a. WWTP Facility Name: Water Reclamation Facility b. WWI P Facility Permit 9: N00024911 All/laws are ie d/CD c. WW I'll klcility's permitted lhat: 40 d. Estimated obligated Iloo not yet tributary to WWTP: 6.5087 c. WWTP facility's ❑coal avg Dow: 20.9545 f.'total naw for this specific request: 0.0009 g. Total actual and obligated flows to the Flcility: 27.4632 / It. Percent ul'pern ued clow used: 69% 11. Complete this section 1'01-cach pump station you are responsible for along the route of this proposed water flow. List pump stations located between the project connection point and the WWTP (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Approx. Obligated, Not Total Current Pump Station Firm Average Daily Current Avg, Yet Tributary Flow plan Available (Name or Capacity." Flow"* (Firm / Daily Flow. Daily Floe, obligated Capacity Number) MGD pf) NIGD MGD MGD Flose !++ Carrier Bridge 22.600 9.040 7.358 1.6246 8.983 0.057 The Firm Capacity of any pump station is defined as the maximum pumped now that can be achieved with the largest pump taken out of service. "" Design Average Daily Flow is the firm capacity or the pump station divided by a peaking factor (pf) not less than 2.5. . "^ A Planning Assessment Addendum shall be attached rot, each pump station located between the project connection point and the WWTP where the Available Capacity is <= 0. Downstream Faciliq' Name (Sewer): AND of Buncombe County Collection System DoN\'nstrcanr Permil Number. WQCS00004 Pane I ol'2 F"FSE 04-16