August 7, 2018
Mr. Mark Harrill
Seven Devils Resort
151 Mr. Bish Blvd
Boone, NC 28607 RECE9VED/DENWOW R
SUBJECT: Compliance Evaluation Inspection AUG 14 2018
Seven Devils Resort WWTP Water Resources
NPDES Permit No. NC0035149 permitting Section
Watauga County
Dear Mr. Harrill,
On August 2, 2018, Kelli Park and Gary Hudson, of this office, met with Josh Cagle
to perform a Compliance Evaluation Inspection on the Seven Devils Resort wastewater
treatment system. Mr. Cagle was filling in for the operator in responsible charge (ORC);
Steve Taylor. This type of inspection consists of two basic parts: an in-office file review
and an on-site inspection of the treatment facility. The attached EPA inspection form
notes the areas that were evaluated for this inspection. The findings and observations
are outlined below:
I
I. Permit
The NPDES permit became effective October 1, 2017, and expires September 30, 2022.
The facility had a copy of the permit available during the inspection.
II. Self-Monitoring Program
A review of the monthly discharge monitoring reports (DMR) for the period January 2017
through August 2018 showed that the facility was not in compliance with all permit limits.
While they were previously addressed before this letter, they are also listed in the table
below.
'1.1TiE )
NORTH CAROJNA
DARItrunt W FmGamnmtal 0.v11�
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103
336.776.9800
. Seven Devils Resort WWTP,August 2,2018
c.
Parameter Violation Date Violation Type
Fecal Coliform 11/21/2017 Daily Max. Exceeded
Fecal Coliform 9/13/2017 Daily Max. Exceeded
Fecal Coliform 8/22/2017 Daily Max. Exceeded
Grab samples are taken by the ORC at the effluent outfall. These samples are put on ice
and analyzed by Water Quality Labs in Banner Elk.
III. Records/Reports
The permit and visitation log are located on site and show visitation times and plant
conditions. Chain of custody forms are in good order. All required monitoring was
performed per the frequencies specified in the NPDES permit. Miss Park noted no data
transcription discrepancies from bench sheets to DMRs in her documentation review.
Water Quality Labs maintains the documentation.
' IV. Flow Measurement
The flow is measured continuously by a v-notch weir with an ultrasonic sensor. The device
was calibrated in July 2018.
V. Operations and Maintenance
The wastewater treatment plant appeared to be well maintained and operated. The ORC
and backup ORC are sufficiently qualified to be running the plant.
Mr. Cagle mentioned that the diffusers in the plant were recently cleaned to improve the
dissolved oxygen levels in the aeration basin.
VI. Facility Site Review
All components of the 0.020 million gallons per day facility appeared to be functioning
properly. The aeration basin had a light brown color and a good earthy odor. All blowers
were functioning properly and there were no dead spots. The secondary clarifier looked
clean, however it was discharging effluent with traces of pin floc. Effluent is disinfected
with chlorine tablets and de-chlorinator tablets before leaving the plant.
Mr. Cagle believes the pin floc to be an inflow and infiltration issue from the heavy rains
over the two weeks prior to the inspection. He reported that the plant will normally
fluctuate around 6,000-11,000 gallons of wastewater a day, but due to the rain the plant
was reading 16,000 gallons of wastewater the day of the inspection and 27,000 gallons
the next day (August 3rd). When Miss Park spoke with him on August 6th Mr. Cagle
reported that there was no pin floc in the effluent, and that it was clear.
2
• Seven Devils Resort WWTP,August 2,2018
The blower house structure is weak and missing large sections of wall around the blowers.
It is recommended that this is repaired or a new structure is built to protect the blowers
and be safer for the operators.
A few areas in the metal walkway over the plant were weak. It is recommended that those
sections be replaced with new metal panels for safety purposes.
VII. Effluent/Receiving Waters
The effluent from the facility was clear, but had pin floc in it the day of the inspection.
Effluent is discharged into an unnamed tributary to the Watauga River, class C; trout
waters in the Watauga river basin. There was no odor associated with the effluent.
VIII. Sludge Maintenance and Handling
Sludge was reported to be pumped about once a year due to low flow in the plant. Triple
T Plumbing pumps the sludge and the time, date, and how much was pumped is recorded
into the operator log on site. It is also documented at Water Quality Labs.
IX. Conclusions
The compliance evaluation inspection is satisfactory. Mr. Cagle maintains and operates
the facility in a good manner. His efforts to comply with the permit are appreciated. If you
have any questions regarding the inspection or this report, please contact Kelli Park or
me at (336) 776-9800.
Sincerely,
Sherri V. Knight, P.E.
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
Attachments: BIMS EPA Water Compliance Inspection Report
cc: Central Files
WSRO
C......._____--NPDES Unit
3
L.
United States Environmental Protection Agency Form Approved
EPA Washington,D C 20460 OMB No 2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A National Data System Coding(i e,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 �,,, L 2 [ I 3 I NC0035149 111 12 1 18/08/02 117 18 I,.I 19 1 S I 201 I
21111111 111 111 111 11 1 11 1111 `1 1 11 111 j 111111 11 I 1166
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved —
67I I 70I I 71 I 1 72 1 N I 731 1 174 751 1 1 1 1 1 1 180
Section B Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 11 30AM 18/08/02 17/10/01
Seven Devils Resort
216 Hardin St Box F-1 Exit Time/Date Permit Expiration Date
Blowing Rock NC 28605 12 00PM 18/08/02 22/09/30
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Joshua Kenneth Cagle/ORC/826-898-6277/
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Randy Carter,151 Mr Bish Blvd Boone NC 28607//828-963-7600/
No
Section C Areas Evaluated During Inspection(Check only those areas evaluated)
▪ Permit • Flow Measurement • Operations&Maintenance • Records/Reports
▪ Self-Monitoring Program • Facility Site Review • Effluent/Receiving Waters
Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Gary Hudson Division of Water Quality//336-776-9694,
Kelli A Park ' Q /pe WSRO WQ//336-776-9689/
vex_
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete
Page# 1
NPDES yr/mo/day ' Inspection Type 1
31 NC0035149 111 121 18/08/02 117 18 I—I C
I
Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
it
Page# 2
lis-
Permit: NC0035149 Owner-Facility: Seven Devils Resort
Inspection Date 08/02/2018 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping'? • ❑ 0 0
Does the facility analyze process control parameters,for ex MLSS, MCRT, Settleable • 0 ❑ 0
Solids, pH, DO, Sludge Judge, and other that are applicable'?
Comment The blower building needs upgraded as it is falling aparet and is missing large sections of
siding Weak spots in the metal walkways over the plant
Permit Yes No NA NE
(If the present permit expires in 6 months or less) Has the permittee submitted a new ❑ ❑ • ❑
application'?
Is the facility as described in the permit'? • 0 ❑ ❑
#Are there any special conditions for the permit'? 0 MI 0 ❑
Is access to the plant site restricted to the general public'? U ❑ ❑ ❑
Is the inspector granted access to all areas for inspection'? • ❑ 0 0 •
Comment
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit'? • 0 ❑ ❑
Is all required information readily available, complete and current'? • ❑ 0 ❑
Are all records maintained for 3 years(lab reg required 5 years)' I ❑ ❑ ❑
Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑
Is the chain-of-custody complete'? • 0 ❑ ❑
Dates, times and location of sampling •
Name of individual performing the sampling IN
Results of analysis and calibration •
Dates of analysis II
Name of person performing analyses MI
Transported COCs MI
Are DMRs complete do they include all permit parameters'? • ❑ ❑ 0
Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑
(If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ • 0
on each shit?
Is the ORC visitation log available and current'? M ❑ ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification'? • ❑ ❑ ❑
Is the backup operator certified at one grade less or greater than the facility classification'? • ❑ ❑ ❑
Is a copy of the current NPDES permit available on site'? • ❑ 0 ❑
Page# 3
m
Permit. NC0035149 Owner-Facility. Seven Devils Resort
Inspection Date: 08/02/2018 Inspection Type Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ • ❑
Comment. _
Bar Screens Yes No NA NE
Type of bar screen
a Manual •
b.Mechanical 0
Are the bars adequately screening debris? • ❑ 0 0
Is the screen free of excessive debris'? • 0 0 ❑
Is disposal of screening in compliance? • ❑ 0 ❑
Is the unit in good condition'? • ❑ ❑ 0
Comment. _
Aeration Basins Yes No NA NE
Mode of operation Ext Air
Type of aeration system Diffused
Is the basin free of dead spots'? • ❑ ❑ ❑
Are surface aerators and mixers operational'? • ❑ 0 0
Are the diffusers operational'? • ❑ ❑ ❑
Is the foam the proper color for the treatment process'? • ❑ ❑ ❑
Does the foam cover less than 25%of the basin's surface'? • 0 0 0
Is the DO level acceptable'? • ❑ 0 0
Is the DO level acceptable?(1 0 to 3 0 mg/I) • ❑ 0 ❑
Comment _
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater'? • ❑ ❑ ❑
Is the site free of excessive buildup of solids in center well of circular clarifier'? • Cl ❑ ❑
Are weirs level'? • ❑ 0 ❑
Is the site free of weir blockage'? • ❑ ❑ ❑
Is the site free of evidence of short-circuiting'? • ❑ ❑ ❑
Is scum removal adequate'? • ❑ ❑ ❑
Is the site free of excessive floating sludge'? • ❑ ❑ ❑
Page# 4
Permit. NC0035149 Owner-Facility Seven Devils Resort
Inspection Date: 08/02/2018 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Is the drive unit operational? • 0 0 0
Is the return rate acceptable(low turbulence)' • 0 ❑ ❑
Is the overflow clear of excessive solids/pin floc'? 0 • ❑ ❑
Is the sludge blanket level acceptable'? (Approximately%4 of the sidewall depth) • ❑ 0 0
Comment Pin Floc being discharged day of inspection
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational'? • ❑ 0 ❑
Are the tablets the proper size and type'? • ❑ ❑ ❑
Number of tubes in use'? 2
Is the level of chlorine residual acceptable'? • ❑ ❑ ❑
Is the contact chamber free of growth, or sludge buildup'? • ❑ ❑ ❑
Is there chlorine residual prior to de-chlorination? ❑ ❑ ❑ •
Comment.
De-chlorination Yes No NA NE
Type of system'? Tablet
Is the feed ratio proportional to chlorine amount(1 to 1)7 U ❑ ❑ El
Is storage appropriate for cylinders'? 0 ❑ U ❑
#Is de-chlorination substance stored away from chlorine containers'? ❑ ❑ MI ❑
Comment. _
Are the tablets the proper size and type? • ❑ 0 ❑
Are tablet de-chlorinators operational'? • El El El
Number of tubes in use'? 1
Comment also throws in loose de chlorination tabs
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained'? • ❑ 0 ❑
Are the receiving water free of foam other than trace amounts and other debris'? • ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly'? U ❑ ❑ ❑
Comment effluent had some pin floc in it