Loading...
HomeMy WebLinkAboutNC0076333_Inspection_20180814NORTH CAROLINA ROY COOPER Envrranrh#1t1G1 QUdlfly G&V 01tw MICHAEL S. REGAL Secr�rary LINDA CULPEPPER In redm D,'rsctor 14 August 2018 Mr. Keith Jones, Maintenance Manager Manheim Statesville 145 Auction Lane Statesville, North Carolina 28625 Subject: Compliance Evaluation Inspection Manheim Statesville Auto Auction WWTP NPDES Permit No. NC0076333 Iredell County Dear Mr. Jones: Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on August 10, 2018, by Mr. Wes Bell of this Office. This inspection included verification of both the connection to the City of Statesville's sanitary sewer system and the status of the cleaning operations on the wastewater treatment facility. Once all wastewater (including solids) are removed from the treatment facility, a request can be made to the Division to rescind the NPDES Permit. The written request must be mailed to the following address: Division of Water Resources, Water Quality Permitting Section — NPDES, 1617 Mail Service Center, Raleigh, NC 27699-1617, attention John Hennessy/Supervisor. Should you have any questions concerning this letter, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bell@ncdenr.gov. Enclosure: Inspection Report Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ EQ.:> "-mr North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue I Suite 3011 Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO076333 111 12 I 18/08/10 I17 18 I S J 19 LG] 201 I 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ----------------------Reserved------------------- 67 1.0 70 I z I 71 In, I 72 I n, I 73 I I I74 751 1 1 1 1 1 1 180 I—I I� I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:25PM 18/08/10 14/05/01 Manheim Stateville Auto Auction 145 Auction Ln Exit Time/Date Permit Expiration Date Statesville NC 28687 02:OOPM 18/08/10 19/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Hayden Hoggard/Engineering Shield/704-394-6913 / Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Keith Jones,145 Auction Ln Statesville INC 28625/Maintenance Manager/704-876-1111/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance Records/Reports Sludge Handling Disposal 0 Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date cuSigned by: Wes Bell MRO WQ//704-663-1699 Ext.2192/ 8/14/2018 Be& E�:96D90=437... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: e� 8/14/2018 A14CC681AF27425... Page# NPDES yr/mo/day Inspection Type NC0076333 111 121 18/08/10 1 17 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) OPERATION & MAINTENANCE SECTION cont'd: The facility's wastewater is conveyed over a creek (via aerial) and into the City of Statesville's sewer system. A large stump had lodged up against the sewer pipe due to the elevated creek levels from the recent rainfall events. Facility staff should periodically inspect this piping system (especially after rainfall events) and remove any large objects that have accumulated up against this section of pipe. Page# Permit: NCO076333 Owner - Facility: Manheim Stateville Auto Auction Yes No NA NE Are records kept and maintained as required by the permit? ❑ Inspection Date: 08/10/2018 Inspection Type: Compliance Evaluation ❑ 0 Is all required information readily available, complete and current? ❑ ❑ ❑ 0 Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the chain -of -custody complete? ❑ ❑ ❑ Is the facility as described in the permit? ❑ ❑ 0 ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The facility has ceased the effluent discharge due to being connected to the City of ❑ Statesville's sanitary sewer system for approximately one month. Transported COCs ❑ The last compliance evaluation inspection was performed at the facility on 8/30/17 by DWR Are DMRs complete: do they include all permit parameters? 0 staff. ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ❑ ❑ ❑ 0 Is all required information readily available, complete and current? ❑ ❑ ❑ 0 Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ 0 Are analytical results consistent with data reported on DMRs? ❑ ❑ ❑ 0 Is the chain -of -custody complete? ❑ ❑ ❑ 0 Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ 0 Comment: Discharge Monitoring Reports (eDMRs) were reviewed for the period July 2017 through June 2018. Daily maximum effluent violations for ammonia (October 2017), BOD (November 2017) and TSS (January 2018) were reported. The Division has separately addressed these violations through the issuance of Notice of Violations (NOVs). Page# 3 Permit: NCO076333 Owner - Facility: Manheim Stateville Auto Auction ❑ ❑ 0 Inspection Date: 08/10/2018 Inspection Type: Compliance Evaluation Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ 0 Record Keeping Yes No NA NE Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: On-site field analvses (DH. temperature. total residual chlorine) were performed under Envirolink, Inc.'s field laboratory certification #5212. Statesville Analytical, Inc. (Certification #440) was also contracted to provide analytical support for the remaining effluent paramenters. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facilitv contracted Bio-Nomic Services. Inc. to clean all tanks and remove all wastewater solids. Only a separate compartment attached to the aeration basin (equipped with a mixer) and the small tank housing the dechlorination unit are left to be cleaned out. The influent pipe for the aerated surge tank/bar screen and effluent pipe have been sealed via concrete. See "Summary" Section for additional comments. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ 0 ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ 0 ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: No evidence of effluent discharges were observed during the inspection. Page# 4