Loading...
HomeMy WebLinkAboutWQ0037504_Issuance of Permit_20180810NORTH CAROLINA ROY COOPER. L%wrom"ental Quality MICHAEL S. REGAL slecMiffy LINDA CULPEPPEI- trrrerfm arxWor August 10, 2018 ROBERT X. AND TRACY M. ST. CLAIR 305 PARKMAN GRANT DRIVE CARY, NORTH CAROLINA 27519 Dear Mr. and Mrs. St. Clair: Subject: Permit No. WQ0037504 524 Carolina Crossings Dr. SFR Single -Family Residence Wastewater Irrigation System Chatham County In accordance with your permit major modification request received July 3, 2018, and subsequent additional information received July 30, 2018, we are forwarding herewith Permit No. WQ0037504 dated August 10, 2018, to Robert X. and Tracy M. St. Clair for the construction and operation of the subject single-family residence wastewater treatment and irrigation facilities. The following modifications to the subject permit are as follows: the treatment system has been changed to: a 1,250 gallon Brantley & Sons ST -323 septic tank; a 1,000 gallon Brantley & Sons PT -237 recirculation tank; a 600 gallon per day (GPD) E -Z Treat Model 600 treatment unit; an E -Z Treat UV 102 ultraviolet disinfection system; and a 4,500 gallon Brantley & Sons PT H2O -506 dosing tank. There is also a decrease in the irrigation area from 0.39 to 0.38 acres due to the addition of a pool, and an approved design flow reduction from 480 GPD to 360 GPD. Please note the Permittee has been changed from KC2 Enterprises, LLC and 1-3, LLC to Robert X. and Tracy M. St. Clair. This permit shall be effective from the date of issuance until July 31, 2023, shall void Permit No. WQ0037504 issued June 30, 2015, and shall be subject to the conditions and limitations as specified therein. An extension shall be requested at least six months prior to the expiration of this permit. Upon receipt of the request, the Commission will review the adequacy of the facility described therein and, if warranted, will extend the permit for such period of time and under such conditions and limitations as it may deem appropriate. .-D-E Q115 North Carolina Department of Environmental Quality I Division of Water Resources I Non -Discharge Branch 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.3654 Mr. Robert X. St. Clair and Mrs. Tracy M. St. Clair August 10, 2018 Page 2 of 2 Please pay particular attention to the operation and maintenance requirements listed in Section III for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. Also note that Condition VI.6. requires the Permittee to retain a set of Division approved plans and specifications for the life of the facilities permitted herein. If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this permit, please contact Erick Saunders at (919) 707-3659 or ericks on. saunders`4? ncdenr. g ov. Sincerely, -tinda Culpepper, Interim Director Division of Water Resources cc: Chatham County Health Department (Electronic Copy) Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Gary MacConnell, PE — MacConnell & Associates (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) Central Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH SINGLE-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Robert X. and Tracy M. St. Clair Chatham County FOR THE construction and operation of a 360 gallon per day (GPD) single-family residence wastewater treatment and irrigation facility consisting of: a 1,250 gallon septic tank with an effluent filter; a 1,000 gallon E -Z Treat recirculation tank with a 13 gallon per minute (GPM), %2 horsepower recirculation pump; a 600 GPD Model 600 E -Z Treat treatment unit; a 4,500 gallon dosing tank with an 18 GPM, 1 horsepower dosing pump; an E -Z Treat Model UV 102 ultraviolet (UV) disinfection system; a 0.38 acre drip irrigation area with two zones; and all associated piping, valves, controls, and appurtenances to serve the single-family residence at 524 Carolina Crossings Dr., Apex, NC 27502, with no discharge of wastes to surface waters, pursuant to the application received July 3, 2018, and subsequent additional information received by the Division of Water Resources, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until July 31, 2023, shall void Permit No. WQ0037504 issued June 30, 2015, and shall be subject to the following specified conditions and limitations: I. SCHEDULES 1. Upon completion of construction and prior to operation of this permitted facility, a certification (attached) shall be submitted from a licensed North Carolina Professional Engineer certifying that the permitted facility has been installed in accordance with this permit, Division approved plans and specifications, and other supporting documentation, including the location of all monitoring wells as applicable. If this project is to be completed in phases and partially certified. the Permittee shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Division of Water Resources, Water Quality Permitting Section, 1617 Mail Service Center, Raleigh, NC 27699-1617. [15A NCAC 02T.01 161 WQ0037504 Version 1.1 Shell Version 180711 Page 1 of 8 2. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least 48 hours in advance (excluding weekends and holidays) of operation of the installed facilities such that an in-place inspection can be made. Notification to the regional supervisor shall be made from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. [15A NCAC 02T .0108 (b)(2)] 3. No later than six months prior to the expiration of this permit, the Permittee shall request renewal of this permit on official Division forms. Upon receipt of the request, the Division will review the adequacy of the facilities described therein, and if warranted, will renew the permit for such period of time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal application. [15A NCAC 02T .0 105, 02T .0 109, 02T .0115(c)] 4. If a public or community sewage system is or becomes available, the subject single-family residence wastewater treatment and irrigation facilities shall be closed and all wastewater shall be discharged into the public or community sewage system within 180 days of its availability. Prior to the initiation of these connection activities, appropriate Division approval shall be received. [15A NCAC 02T .0607] II. PERFORMANCE STANDARDS The subject non -discharge facilities shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to adequately assimilate the effluent, the Permittee shall take immediate corrective actions including Division required actions, such as the construction of additional or replacement wastewater treatment or disposal facilities. [15A NCAC 02T .0108(b)(1)] 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. [ 15A NCAC 02B .0200, 02L .0100] 3. Application rates, whether hydraulic, nutrient or other pollutant, shall not exceed those specified in the following table: TABLE 1— APPLICATION LIMITATIONS Field Parameter Hourly Rate Yearly Max Units 1 01284 — Non -Discharge Application Rate 0.13 12.8 inches [15A NCAC 02T .06050)] 4. The subject facility has been approved to land apply wastewater effluent on the following fields: TABLE 2 — IRRIGATION AREA INFORMATION Net Dominant Field Owner County Latitude Longitude Acreage Soil Series Robert X. and Tracy M. St. 1 Chatham 35.7967550 -78.9574870 0.38 Creedmoor Clair [G. S. 143-215.11 5. The Operation and Maintenance Agreement (attached) between the Permittee and the Division of Water Resources is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operation and Maintenance Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes § 143-215.6A to § 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. [15A NCAC 02T .0115 (2)] WQ0037504 Version 1.1 Shell Version 180711 Page 2 of 8 6. The irrigation system shall be connected to a rain or moisture sensor, which shall indicate when effluent application is not appropriate in accordance with Conditions III.4. and 111. 5. of this permit. [15A NCAC 02T .0605(o)] 7. The compliance boundary is established at the property boundary. Any exceedance of standards at the compliance boundary shall require action in accordance with 15A NCAC 02L.0106. [ 15A NCAC 02L .0107(i)] 8. The review boundary is established midway between the compliance boundary and the effluent disposal area. Any exceedance of groundwater standards at the review boundary shall require action in accordance with 15A NCAC 02L.0106. [15A NCAC 02L .0108] 9. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary. [ 15A NCAC 02L .0107(c)] 10. The facilities permitted herein shall be constructed according to the following setbacks: a. The setbacks for irrigation sites permitted under 15A NCAC 02T .0600 shall be as follows (all distances in feet): i. Any habitable residence or place of public assembly under separate ownership: 100 ii. Any habitable residence or place of public assembly owned by the Permittee: 15 iii. Any private or public water supply source: 100 iv. Surface waters: 100 v. Groundwater lowering ditches: 100 vi. Surface water diversions: 25 vii. Any well with exception of monitoring wells: 100 viii. Any property line: 50 ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15 x. Any water line from a disposal system: 10 xi. Subsurface groundwater lowering drainage systems: 100 xii. Any swimming pool: 100 xiii. Public right of way: 50 xiv. Nitrification field: 20 xv. Any building foundation or basement: 15 [ 15A NCAC 02T .0606(a)] b. The setbacks for storage and treatment units permitted under 15A NCAC 02T .0600 shall be as follows (all distances in feet): i. Any habitable residence or place of public assembly under separate ownership: ii. Any private or public water supply source: iii. Surface waters: iv. Any well with exception of monitoring wells: v. Any property line: [I 5A NCAC 02T .0606(b)] 100 100 50 100 50 WQ0037504 Version 1.1 Shell Version 180711 Page 3 of 8 III. OPERATION AND MAINTENANCE REOUIREMENTS 1. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. The Permittee shall maintain an Operation and Maintenance Plan pursuant to 15A NCAC 02T .0604(f). [ 15A NCAC 02T .0604(f)] 2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC) classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or more certified operator(s) as back-up ORC(s) unless otherwise stated in 15A NCAC 08G .0304. The ORC or their back-up shall visit the facilities in accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the previously cited rules. [ 15A NCAC 02T .0117] 3. A suitable year round vegetative cover shall be maintained at all times, such that crop health is optimized, allows for even distribution of effluent and allows inspection of the irrigation system. [ 15A NCAC 02T .0108(b)(1)] 4. Adequate measures shall be taken to prevent effluent ponding in or runoff from the irrigation sites listed in Condition I1.4. [15A NCAC 02T .0605(o)] 5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause ponding or runoff. [15A NCAC 02T .0605(o)] 6. Only effluent from the single-family residence at 524 Carolina Crossings Dr., Apex, NC 27502 shall be irrigated on the sites listed in Condition II.4. [G. S. 143-215.1] 7. No automobiles or machinery shall be allowed on the irrigation sites except during equipment installation or while maintenance is being performed. [15A NCAC 02T .0108(b)(1)] 8. Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. Fencing shall be provided to prevent access to the irrigation site (minimum 2 -strand wire) and treatment units shall be secured with locks on all tank accesses and control panels. [15A NCAC 02T .0605(1)] 9. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in accordance with 15A NCAC 02T.1100. [15A NCAC 02T .1100]. 10. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is prohibited. [15A NCAC 02T .0605(f)] 11. Pump/dosing tanks shall have audible and visual alarms external to any structure. [15A NCAC 02T .0605(n)] 12. Any excavation into bedrock shall be lined with a 10 millimeter (mm) synthetic liner. [ 15A NCAC 02T .0605(d)] WQ0037504 Version 1.1 Shell Version 180711 Page 4 of 8 13. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal system including, but not limited to, the following items: a. The septic tank shall be checked annually and pumped out as needed. The septic tank effluent filter shall be checked and cleaned at the same frequency as the septic tank. [ 15A NCAC 18A .1900, 02T .0605] b. The ultraviolet disinfection unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection. [15A NCAC 02T :0605(1)] c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer in the pump tanks shall be removed at the same interval as the septic tank is cleaned out. [15A NCAC 02T .0108(b)(1)] d. The system shall be inspected monthly to make certain of the proper operation of the drip lines, that the system is free of leaks, that the vegetative growth allows a proper drip pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. [15A NCAC 02T .0108(b)(1)] IV. MONITORING AND REPORTING REQUIREMENTS 1. Any Division required monitoring (including groundwater, plant tissue, soil and surface water analyses) necessary to ensure groundwater and surface water protection shall be established, and an acceptable sampling reporting schedule shall be followed. [15A NCAC 02T .0108(c)] 2. Noncompliance Notification: The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 791- 4200, as soon as possible, but in no case more than 24 hours, or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons, rendering the facility incapable of adequate wastewater treatment. b. Any facility failure resulting in a by-pass directly to receiving surface waters. Any time self-monitoring indicates the facility has gone out of compliance with its permit limitations. d. Ponding in or runoff from the irrigation sites. Any emergency requiring immediate reporting (e.g., discharges to surface waters, imminent failure of a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to betaken to ensure the problem does not recur. [15A NCAC 02T .0105(1)] WQ0037504 Version 1.1 Shell Version 180711 Page 5 of 8 V. INSPECTIONS 1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the wastewater treatment and irrigation facilities. [15A NCAC 02T .0108(b)] The Permittee or their designee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions, facility deterioration and operator errors resulting in discharges, which may cause the release of wastes to the environment, a threat to human health or a public nuisance. The Permittee shall maintain an inspection log that includes, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. [15A NCAC 02T .0108(b)] 3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the wastewater treatment and irrigation facilities permitted herein at any reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records required to be maintained under the terms and conditions of this permit, and may collect groundwater, surface water or leachate samples. [G.S. 143-215.3(a)(2)] VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statutes 143-215.6A to 143-215.6C. [G.S. 143-215.6A to 143-215.6C] 2. This permit shall become voidable if the permitted facilities are not constructed in accordance with the conditions of this permit, the Division approved plans and specifications, and other supporting documentation. [15A NCAC 02T .0110] 3. This permit is effective only with respect to the nature and volume of wastes described in the permit application, Division approved plans and specifications, and other supporting documentation. No variances to applicable rules governing the construction or operation of the permitted facilities are granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T .0105(n). [G.S. 14.-215.1] 4. Pursuant to the flow reduction request received July 3, 2018 and approved July 31, 2018, the Division accepts the data -based design flow rate of 90 gallons per day per bedroom (GPD/BR) for the users served by this facility. Regardless of the adjusted daily wastewater design flow rate, at no time shall wastewater flows exceed the limits defined in this permit for the subject facility, or exceed the sewer capacity downstream of any new sewer extension or service connection(s). The Permittee shall report the actual (i.e., measured) monthly average amount of wastewater flow contributed per unit (GPD/BR) for the 12 months prior to permit renewal. If any of these actual monthly averages are within 20% of the approved value, the Permittee shall re-evaluate the approved value using the methodology applied to determine the approved flow rate of 90 GPD/BR, and submit this information within 18 months. The Division may change the daily wastewater design flow rate for connections to the system at that time, and upon each renewal cycle, pending an evaluation of the submitted flow information. [ 15A NCAC 02T .0114(f)] 5. The Permittee shall retain the Division's written approval of any authorized adjusted daily design flow rate for the life of the facility, and shall transfer said written approval to any future Permittee. [I 5A NCAC 02T .0114(f)] WQ0037504 Version 1.1 Shell Version 180711 Page 6 of 8 The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies (e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules in 15A NCAC 02B .0200; erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under General Permit NCGO10000; any requirements pertaining to wetlands under 15A NCAC 02B .0200 and 02H .0500; and documentation of compliance with Article 21 Part 6 of Chapter 143 of the General Statutes. [15A NCAC 02T .0105(c)(6)] 7. In the event the permitted facilities change ownership or the Permittee changes their name, a formal permit modification request shall be submitted to the Division. This request shall be made on official Division forms, and shall include appropriate property ownership documentation and other supporting documentation as necessary. The Permittee of record shall remain fully responsible for maintaining and operating the facilities permitted herein until a permit is issued to the new owner. [15A NCAC 02T .0104] 8. The Permittee shall retain a set of Division approved plans and specifications for the life of the facilities permitted herein. [15A NCAC 02T .0108(b)(1)] 9. The Permittee shall maintain this permit until all permitted facilities herein are properly closed or permitted under another permit issued by the appropriate permitting authority. [ 15A NCAC 02T .01050] 10. This permit is subject to revocation or unilateral modification upon 60 days notice from the Division Director, in whole or part for the requirements listed in 15A NCAC 02T .0110. [ 15A NCAC 02T .0110] 11. Unless the Division Director grants a variance, expansion of the permitted facilities contained herein shall not be granted if the Permittee exemplifies any of the criteria in 15A NCAC 02T .0120(b). [ 15A NCAC 02T.0120] 12. The Permittee shall pay the annual fee within 30 days after being billed by the Division. Failure to pay the annual fee accordingly shall be cause for the Division to revoke this permit. [15A NCAC 02T .0105(e)(3)] Permit issued this the 10a' day of August 2018 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION nda Culpepper, Interim Director (1 Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0037504 WQ0037504 Version 1.1 Shell Version 180711 Page 7 of 8 Permit No. WQ0037504 Single -Family Residence Wastewater Irrigation System Robert X. and Tracy M. St. Clair August 10, 2018 524 Carolina Crossings Dr. SFR Chatham County ENGINEERING CERTIFICATION ❑ Partial ❑ Final In accordance with 15A NCAC 02T .0 116, I, _, as a duly registered Professional Engineer in the State of North Carolina, having the Permittee's authorization to ❑ periodically ❑ weekly ❑ fully observe the construction of the permitted facility, hereby state to the best of my abilities that due care and diligence was used in the observation of the construction, such that the facility was built within substantial compliance and intent of this permit, the Division approved plans and specifications, and other supporting documentation. ❑ Any variation to this permit, the Division approved plans and specifications, and other supporting documentation has been documented in the attached as -built drawings, and shall serve as the Permittee's minor modification request to amend the permit accordingly. Provide a brief narrative description of any variations: Professional Engineer's Name Engineering Firm Mailing Address City State ! Zip ..... ..... .... ............ ........ .... _.... ........................ ... .... t Telephone E-mail NC PE Seal, Sipafore &Date THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES WATER QUALITY PERMITTING SECTION NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: 1617 MAIL SERVICE CENTER By Courier/Special Delivery: 512 N. SALISBURY ST. RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 WQ0037504 Version 1.1 Shell Version 180711 Page 8 of 8 State of North Carolina Department of Environment and Natural Resources Division of %Pater Resources 15A 11'CAC 02T .0600 – SINGLF-FA LILY RESIDENCE %I'ASTEWATER IRRIGATION SYSTF,MS RP* OPERATION AND MAINTENANCE AGREEM Division of Water Resources ENT FORM: SFRR'WIS O&M 08-13 Permit No. wo 0n3 u- 0 4— County. Property owner(s) as appearing on the recorded deed: "�� Mailing address: r- Facility address: , D. -:.lo Irrigation Method: ❑ SPRAY 0 DRIP 1 / We agree to operate and maintain the single-family residence wastewater treatment and irrigation system as follows: I. The Permittee is responsible for the operation and maintenance of the entire wastewater treatment and irrigation system including, but not limited to, the following items: a. The septic tank shall be checked annually and pumped out as needed. b. The septic tank effluent filter shall be checked and cleaned annually. C. Accessible sand filter surfaces shall be raked and leveled every six months and any vegetative growth shall be removed manually. d• ❑ The tablet chlorinator shall be checked weekly. Wastewater grade tablets (calcium hypochlorite) shall be added as needed to provide proper chlorination (pool chlorine tablets shall not be used), OR WThe ultraviolet disinfection unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection. e. All pump and alarm systems shall be inspected monthly. f. The irrigation system shall be inspected monthly to ensure that the system is free of leaks, that all irrigation equipment is operating as designed, that vegetative growth does not interfere with the system inspection or operation, that the soil is assimilating the disposed treated wastewater with no visible runoff or ponding, and that no objectionable odors are being generated. 2. Failure to pay the annual fee shall he cause for the Division to revoke the permit pursuant to 15A NCAC 02T .0105(e)(3). 3. The Permittee's failure to properly operate this system is subject to a penalty up to $25,000 per day. 4. Failure to meet the permit conditions or violation of the State's surface water or groundwater regulations may void the permit. All owners_�2pearIng on thele allti recorded ro rte deed shall si n this O eralion & Maintenance A reement I/ We understand the above requi mpnts and agree to these erms as part of the issued permit. Owner Signature: Date: Owner Signature: Date: r 4 FORM: SFRWWIS O&M 08-13 Page 1 of 1 Scanned with CamScanner w CD WQ0037504 Version 1.1 Shell Version 171103 Page 7 of 8