Loading...
HomeMy WebLinkAboutWQ0001048_Issuance of Permit_20180810�q{fyyVF� NORTH CAROLINA Ploy COOPER EnWemmental Quathy c MICHAEL S. REGAN Secretary In "fertm iakreZiw August 10, 2018 CHARLES M. SMITHWICK, JR. — DISTRICT MANAGER CONTENTNEA METROPOLITAN SEWERAGE DISTRICT POST OFFICE BOX 477 GRIFTON, NORTH CAROLINA 28530 Subject: Attachments B and C Certification Permit No. WQ0001048 Contentnea MSD RLAP Pitt County Dear Mr. Smithwick: In accordance with your permit modification request received April 10, 2018, and subsequent additional information received June 20, 2018, we are forwarding herewith modified Attachments B and C certified August 10, 2018, to Contentnea Metropolitan Sewerage District for the subject residuals program. This certification is being issued to modify Attachments B and C by: 1. Addition of two fields in Pitt County totaling 13.61 acres, those fields being CII -19 and -20; and 2. Transfer of MW -17 from permit WQ0022384 to this permit. This modified Attachments B and C shall be effective from the date of certification until January 31, 2020 (i.e., expiration date of the current permit), shall void Attachments B and C of Permit No. WQ0001048 issued December 2, 2014, and shall be subject to the conditions and limitations as specified therein, as well as those specified in the above -referenced permit. Please replace Attachments B and C of Permit No. WQ0001048 that was issued December 2, 2014 with these modified Attachments. Please note that only the maps for new land application sites are attached to this letter. It is the Permittee's responsibility to ensure that a complete permit is created by inserting these documents into the previously issued permit. o �,D _. E Q 2p� North Carolina Department of Environmental Quality I Division of Water Resources I Non -Discharge Branch 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.3654 Mr. Charles M. Smithwick, Jr. August 10, 2018 Page 2 of 2 If any parts, requirements, and/or limitations contained in this certification or modified Attachments B and C are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of the certification. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need any additional information concerning this matter, please contact Troy Doby at (919) 707-3655 or troy.doby&cdenr.gov. Sincerely, Linda Culpepper, Interim Director Division of Water Resources cc: Pitt County Health Department (Electronic Copy) Washington Regional Office, Water Quality Regional Operations Section (Electronic Copy) C. Scott Carpenter, LSS — Soil Plus (Electronic Copy) Digital Permit Archive (Electronic Copy) Central Files ATTACHMENT B - Approved Land Application Sites Contentnea Metropolitan Sewerage District Certification Date: August 10, 2018 Permit Number: WQ0001048 Version: 3.1 Field Owner Lessee County Latitude Longitude Net Acreage Dominant Soil Series Figures B-1 Contentnea Metropolitan Sewerage District Mills Creston Pitt 35.3599720 -77.4175780 2.84 Po - Portsmouth B-2 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.360203° -77.4181030 2.62 Pa - Pactolus B-3 Contentaea Metropolitan Sewerage District Mills, Creston Pitt 35.3603470 -77.4184890 2.72 Po - Portsmouth B-4 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3604740 -77.4189190 3.34 Pa - Pactolus B-5 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3606440 -77.419597° 3.74 Pa - Pactolus B-6 Contentnea Metropolitan Sewerage District Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3584560 -77.417994° 2.48 Ch - Chipley B-7 Mills, Creston Pitt 35.3585110 35.3663440 -77.4210750 -77.4194690 -77.4201580 1.32 Ch - Chipley CI -10 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 8.55 7.73 AgB - Alaga CII -08 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3670330 AgB - Alaga CII -09 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3678330 -77.4199310 5.15 AgB - Alaga CII -13 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3653060 -77.4165060 3.30 OcB - Ocilla CII -19 Contentnea Metropolitan Sewerage District Mills, Creston Ray Mills, Creston Ray Pitt Pitt 35.366825 35.365506 -77.415167 -77.414539 11.75 1.86 AgB - Alaga OcB - Ocilla 1 1 CII -20 Contentnea Metropolitan Sewerage District CIII-12 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3618030 -77.4149280 5.23 Os - Osier CIV -11 Contentnea Metropolitan Sewerage District Mills, Creston Pitt 35.3625030 -77.4159890 5.13 Pa - Pactolus D-14 Gaskins, Michael Mills, Creston Pitt 35.3629890 -77.4099970 3.00 Po - Portsmouth D-15 Gaskins, Michael Mills, Creston Pitt 35.3625720 -77.4099810 2.38 Po - Portsmouth D-16 Gaskins, Michael Mills, Creston Pitt 35.3620220 -77.4099440 2.98 AgB - Alaga D-17 Gaskins, Michael Mills, Creston Pitt 35.3612780 -77.4100170 3.62 AgB - Alaga D-18 Gaskins, Michael Mills, Creston Pitt 35.3602440 -77.4103390 2.42 Pa - Pactolus Total 82.16 WQ0001048 Version 3.1 Attachment B Page 1 of 1 THIS PAGE BLANK ATTACHMENT C — Groundwater Monitoring and Limitations Contentnea Metropolitan Sewerage District Monitoring wells: MW -9, MW -10, MW -14, MW -15, MW -17, and MW -18 Certification Date: August 10, 2018 Permit Number: WQ0001048 Version: 3.1 GROUNDWATER CHARACTERISTICS PCS Code Parameter Description GROUNDWATER STANDARDS Daily Maximum MONITORING REQUIREMENTS Frequency Measurement Sample Type Footnotes 00680 Carbon, Tot Organic (TOC) mg/L 3 x Year Grab 1,6,7 01034 Chromium, Total (as Cr) 10 µg/L 3 x Year Grab 1,7 31616 Coliform, Fecal MF, M -FC Broth,44.5°C #/100mL 3 x Year Grab 1,7 01042 Copper, Total (as Cu) 1 mg/L 3 x Year Grab 1,7 00610 Nitrogen, Ammonia Total (as N) 1.5 mg/L 3 x Year Grab 1,7 00620 Nitrogen, Nitrate Total (as N) 10 mg/L 3 x Year Grab 1,7 00400 pH 6.5-8.5 su 3 x Year Grab 1,7 70300 Solids, Total Dissolved- 180°C 500 mg/L 3 x Year Grab 1,7 GWVOC Volatile Compounds, (GC/MS) Present: Yes/No Annually Grab 1,4,5,7 82546 Water Level, Distance from measuring point feet 3 x Year Calculated 1,2,3,7 1. 3 x Year monitoring shall be conducted in February, June, and October; Annual monitoring shall be conducted every October. 2. The measurement of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement of pH shall be made after purging and prior to sampling for the remaining parameters. 3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top of casing) of all monitoring wells shall be surveyed relative to a common datum. 4. Volatile Organic Compounds (VOC) - In October only, analyze by one of the following methods: a. Standard Method 6230D, PQL at 0.5 gg/L, or less b. Standard Method 6210D, PQL at 0.5 gg/L or less c. EPA Method 8021, Low Concentration, PQL at 0.5 gg/L or less d. EPA Method 8260, Low Concentration, PQL at 0.5 µg/L or less c. Another method with prior approval by the Water Quality Permitting Section Chief Any method used must meet the following qualifications: a. A laboratory must be DWQ certified to run any method used. b. The method used must, at a minimum, include all the constituents listed in Table VIII of Standard Method 6230D. c. The method used must provide a PQL of 0.5 gg/L or less that must be supported by laboratory proficiency studies as required by the DWQ Laboratory Certification Unit. Any constituents detected above the MDL but below the PQL of 0.5 gg/L must be qualified (estimated) and reported. 5. If any volatile organic compounds (VOC) are detected as a result of monitoring as provided in Attachment C, then the Washington Regional Office supervisor, telephone number (252) 946-6481, must be contacted immediately for further instructions regarding any additional follow-up analyses required. WQ0001048 Version 3.1 Attachment C Page 1 of 2 ATTACHMENT C — Groundwater Monitoring and Limitations Contentnea Metropolitan Sewerage District Certification Date: August 10, 2018 Permit Number: WQ0001048 Version: 3.1 6. If TOC concentrations greater than 10 mg/L are detected in any downgradient monitoring well, additional sampling and analysis must be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mg/L, this concentration will be taken to represent the naturally occurring TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. 7. Monitoring wells shall be reported consistent with the nomenclature and location information provided in this attachment. WQ0001048 Version 3.1 Attachment C Page 2 of 2 N WE 1 v*y.� I 50- I 7.51 Gross.Ac 4 84;Net Ac,, W-'4 �<r'-ra�t:e 9.95 Gross Ac, 7.31 Net Ac. 6.60 Irrigated Ac. Field 10 12.29 Grcis's A 7.95 NeuAc 6.37 Irrirat( d N -e' Field 19 14.78 Gross Ac. 11.75 Net Ac. 10.42 Irrigated Ac. Field 21, 2.27 Gross -Ac. 1.80 Net Ac. Field 13 1.86 Irrigated Ac. 3.30 Gross Ac, 2.90 Net Ac, 2.90 Irrigated Ac. ,-y":I v 9.87 Gras, Ac.w ♦ Legend 13►Nct.Ac. 4 O7 IfrigatedAc. � ■ Monitor Well The Compliance Boundary shall be ■ House located 50 feet within the property line — , Stream or 250 feet from the edge of the ' disposal area, whichever is closer to the - - Ditch source. The Review Boundary shall be located halfway in between the property Net Area line and the Compliance Boundary. ® Buffer Field Boundary 0 150 300 600 CI Pond mommommi Feet Scale:1 inch = 300 feet BUFFER MAP 19 & 20 FIGURE Drawn By: CSC SOIL PLUs S CMSD CLASS B LAND APPLICATIO Reviewed By: I W1111111111111W Class B Permit WQ0001048 1 Date: June '18 ISoil Plus Project # 200710.A10