Loading...
HomeMy WebLinkAboutWQ0040181_Application (FTSE)_20180807Perrnit Number . WQ0040181 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer helen.perez Coastal SWRule Permitted Flow Facilitv Facility Mame Orange Street Sewer Replacement Location Address Owner Central Files: APS . SWP 7/26/2018 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Carteret Facility Contact Affiliation Owner Marne owner Type, Town of Beaufort Government - Municipal Owner Affiliation Richard L. Stanley PO Box 390 Dates/Events Beaufort NC 28516039 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration C7/24/2018 •Regullated Activities Requested /Received Events Additional information requested Additional information received : To • NCDEQ-WATER QUALITY SECTION 127 CARDINAL DRIVE EXT WILMINGTON, NC 28405 WE ARE SENDING YOU: THE C U LLI P H E R GROUP, P.A. ENGINEERING & SURVEYING SERVICES HESTRON PLAZA TWO 151-A NC HWY 24 MOREHEAD CITY, NC 28557 P:(252) 773-0090 F:(252) 773-0243 kqFCF'VED/NCDENR/DWR JUL g 5 2018 Nater Qu,@14 Regional . Operations Section Wilmington Regional Office e DATE 07/20/18 JOB NO. PM493-34E ORANGE STREET ATTENTION DEAN HUNKELE RE: ORANGE STREET IMPROVEMENTS BEAUFORT, CARTERET COUNTY COPIES DATE NO. DESCRIPTION 1 COVER LETTER 1/1 ORIGINAL AND COPY FTA 04-16 APPLICATION 1 APPLICATION FEE $480.00(rnailed separately by Town of Beaufort) 2 USGS TOPO MAP 2 STREET LEVEL MAP THESE ARE TRANSMITTED as checked below: ❑ For approval ❑Resubmit copies for approval ❑ For your use Submit copies for distribution F-1 As requested ZFor review and comment F-1 FOR BIDS DUE El PRINTS RETURNED AFTER LOAN TO US REMARKS PLEASE CALL OR EMAIL WITH ANY QUESTIONS. ron@tcgpa.com COPY TO SIGNED RONALD D. CULLIPHER, PE CI� THE CULLIPHER GROUP, P.A. ENGINEERING & SURVEYING SERVICES July 20, 2018 NCDEQ Wilmington Regional Office Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405 RE: Orange Street Improvements Modification to WQ (unknown) Town of Beaufort, Carteret County This request for modification is to remove and replace the existing 8" gravity sewer at the southern end of Orange Street, between Ann and Front Streets. There is no additional flow requested for the project. The following are included in the application package: • Check # in the amount of $480.00 (#047845 mailed separately) � FTA 04-16 • USGS Topographic Map • Street level map If you have any questions or concerns please do not hesitate to contact me. Sincerely, � • ! e i Ronald D. Cullipher, PE, : SEAL ; Q 13343 HESTRON PLAZA TWO 151-A NC HWY 24 MOREHEAD CITY, NC 28557 (252) 773-0090 r It D:WR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: Whoa �(u (81 (to be completed by DWR) All items must be comuieted or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Beaufort (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: John Day per 15A NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: 701 Front Street �r City: Beaufort State: NC Zip: 28516- 5. Applicants contact information: JUL 2 6 Phone number: 252) 728-2141 Email Address: j.day@beaufolinc.org BY: H. PROJECT INFORMATION: 1. , Project name: Orange Street 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Carteret 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.718° Longitude: -76.667° 5. Parcel ID (if applicable): N/A (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: 1. Professional Engineer: Ronald D Cullipher License Number: 13343 Firm: The Cullipher Group, PA Mailing address: 151-A Highway 24 City: Morehead City State: NC Zip: 28557 - Phone number:2( 52) 773-0090, Email Address: ron @ tcgpa.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Beaufort WWTP Permit Number: NC 0021831 Owner Name: Town of Beaufort V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes ❑ZN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEBT} been attached? ❑ Yes []No ®NIA 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HDA) been attached? ❑ Yes []No NN/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) E:] Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care El Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities [:1 Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories El Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T.01 (20)} is there a Pretreatment Program in effect? ❑ Yes El No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f}? ❑ Yes No ➢ If y,es, grlvide a co,lpy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gall GPD gal/ GPD gall GPD Total 0 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4}. b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line EJ Flow has already been allocated in Permit Number: Z Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 b VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) -02T.0305 & IDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 479 SDR35 8 40 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (lamp Stations/Force Mains): COMPLETE FOR EACH PUMP, STATION INCLUDED IN TTI1IS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)` ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) El Yes ❑ No 15A NCAr n2T_nIn5(f)cnntninc minim»m cennrntinnc that shall hP nrnvidt-ti fnr cPwPr evctPmc• Setback Parameter* Se aration Required Storm sewers and other utilities not listed below vertical 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines(horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS -I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS -I or WS -V), B, SA, ORW, HQW, or SB from normal high water or tide elevation) and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any buildingfoundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming ools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.030_ 5() contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ "Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g)see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) 0 Yes EI No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® NIA ➢ This would include Trout Buffered Streams per 15A NCAC 2B .0202 4. Does the project require coverage/authorization under a 404 Nationwide or El Yes EJ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting_ Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -'Vide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATION'S: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? N Yes [:1 No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to sum 1 of the Fast Track Application and uuporting documents. 2. Professional Engineer's Certification: I, Ronald D. Cullipher, PE attest that this application for (Professional Engineer's name from Application Item 111. 1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. ......................................................................................... North Carolina Professional Engineer's seal, signature, and date:CA •G 114 ► ..............................:.A'! - �... ,�....... ....... ,,��rl� 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, John Day, Town Manager attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04-16 Page 5 of 5 O O O LO O 'O V 00 r - C) N co co CL co 2 S _ _ i F `fir _ .� .yam•.. 16 • .' �rtAf op 0- s _ 4 41 12 a \ i� t z m .a O O O LO O 'O V 00 r - C) N co co CL co 2 N (O LO N ti O O O O co t -- co O M O N ti d' co U (a E E O U N O O) N Q .0 S _ _ i F `fir _ .� .yam•.. • .' . op 0- s _ 4 41 12 a \ i� t z m .a N (O LO N ti O O O O co t -- co O M O N ti d' co U (a E E O U N O O) N Q .0