Loading...
HomeMy WebLinkAboutNC0068152_Compliance Evaluation Inspection_20180716DocuSign Envelope ID: C763963A-5BDA-4A2A-801A-56E4AA6F0817 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO068152 111 12 I 18/06/20 I17 18 Lam] 19 LG] 201 I 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ----------------------Reserved------------------- 67 70 I I 71 I I 72 I r l 73 I I 174 751 I I I 1 1 1 I80 u ty I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 09:30AM 18/06/20 16/08/01 Eden Glen Mobile Village WWTP 2 Gospel Way Exit Time/Date Permit Expiration Date Weaverville NC 28787 11:00AM 18/06/20 20/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Randy Roberson, //828-779-5265/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance Records/Reports 0 Self -Monitoring Program Sludge Handling Disposal 0 Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs Ds ARO WQ//828-296-4500 Ext.4653/ Timothy H Heim EW ARO WQ//828-296-4665/ DocuSigned by: Signature of MTment� r Agency/Office/Phone and Fax Numbers Date �1� 7/13/2018 7E617A38285848C... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: C763963A-5BDA-4A2A-801A-56E4AA6F0817 NPDES yr/mo/day Inspection Type (Cont.) NCO068152 111 121 18/06/20 117 18 S Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The inspectors, Linda Wiggs and Tim Heim met with Joe David Hall (ORC). The plant was observed to be producing good quality effluent at the onset of the inspection and during the split sampling. However, further into the inspection there appeared to be a hydraulic "surge" from the aeration basin through the clarifier that move a significant amount of solids into the chlorine contact chamber and subsequently the receiving stream. Split samples, DWR results were: Fecal Coliform — 96 CFU/100ml BOD — 6.8 mg/I TSS — 8.3 mg/I NH3 — 0.04 mg/I Solids were high in the plant and did not settle. The ORC stated the digester had been pumped May 11, 2018 by Carter Septic. Considerable structural decay was observed throughout the WWTP. Refer to TA report for additional comments. Page# DocuSign Envelope ID: C763963A-5BDA-4A2A-801A-56E4AA6F0817 Permit: NCO068152 Owner - Facility: Eden Glen Mobile Village WWTP Inspection Date: 06/20/2018 Inspection Type: Compliance Sampling Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ 0 ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Observations and process controls conducted during inspection indicate solids issues. Considerable structural decay was noted. Solids were observed in effluent after blower shut-off. See summary and TA report. Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: D.O. readings were between 2.87-3.47 mg/I. Air was set for 30 min.ON/45 min. OFF. Settleability was unacceptable at 95%. Foam approaching 50%. Considerable structural decay was noted at aeration basin and clarifier function/wall. See summary and TA report. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ 0 ❑ Page# 3 DocuSign Envelope ID: C763963A-5BDA-4A2A-801A-56E4AA6F0817 Permit: NC0068152 Inspection Date: 06/20/2018 Secondary Clarifier Owner - Facility: Eden Glen Mobile Village WWTP Inspection Type: Compliance Sampling Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) Yes No NA NE ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ Comment: Blanket levels were high; 4.5'/7' and 6/7'. Excessive solids left the clarifier; a surge occurred when the blower shut-off. This hydraulic surge also allowed wastewater to bypass the chlorine tablets tube, predominantly where structural decay was present. See summary and TA report. Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Chlorine contact blanket was 1.576'. Structural issues were noted at the tablet chlorinator and the clarifier iunction. De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ \[T-1111111'!NNZF_'mZI=111111 Tablet ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ E ❑ ❑ ❑ ❑ ❑ ❑ Page# 4 DocuSign Envelope ID: C763963A-5BDA-4A2A-801A-56E4AA6F0817 Permit: NCO068152 Owner - Facility: Eden Glen Mobile Village WWTP Inspection Date: 06/20/2018 Inspection Type: Compliance Sampling De -chlorination Yes No NA NE Comment: Tube attached after weir. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ❑ ❑ 0 ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ 0 ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ 0 ❑ representative)? Comment: Samples are to be obtained at effluent pipe. DWR split samples with ORC. See summary for results. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: Page# 5