Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG190106_NOI Application_20180731
Environmental Quality Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCG190000 FOR AGENCY USE ONLY Date Received Year Month Dav Certificate of Covera fe N Check N ,\mount Permit Assumed to NOTICE OF INTENT I 'cV / q01 O 6 National Pollutant Discharge Elimination System application for coverage under General lPermit NCG 190000: STORMWATER DISCHARGES associated with activities classified as: SIC" (Standard Industrial Classification) 373 Ship and Boat Building and Repairing SIC* 4493 Marinas * Standard Industrial Classification Code t For questions, please contact the DEMLR Regional Office for your area. (See page 4) (Please print or type) 1) Mailing address of owner/operator (address to which all permit correspondence will be mailed): Name United States Army Corps of Engineers- Wilmington District Owner Contact Daniel Brown Street Address 69 Darlington Avenue City Wilmington State NC ZIP Code 28403 Telephone No. 910 251-4832 Fax: E-mail Address Daniel.S.Brown@usace.army.mil 2) Location of facility producing discharge: Facility Name Engineering Repair Yard Facility Contact Craig Garrison (Alternate Contact- Kenneth Bailey (910) 251-4617) Street Address 323 Battleship Rd. NE City Wilmington State NC ZIP Code 28451 County New Hanover Telephone No. 910 251-4853 Fax: Email Craig.Garrison@usace.army.mil (Alternate contact- Kenneth.S.Bailey.JR@usace.army.mil) 132 3) Physical Location Information: 3qo�LIvvL Ir/7.�� Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From the Battleship North Carolina, drive south on Battleship Rd. NE. Continue until passing under the Cape Fear Memorial Bridge. The Engineering Repair Yard is the first property East of Battleship Rd. south of the bridge (A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application.) 4) Latitude 340 13' 41" N Longitude 770 57' 17" W (degrees, minutes, seconds) 5) This NPDES Permit Application applies to which of the following : ❑ New or Proposed Facility* Date operation is to begin ✓❑ Existing RECEIVED '"L 23 2018 DENR-LAND QUALITY �"ORMWATER PERMITTING *If this new or proposed facility in one of the 20 coastal counties, you must contact the appropriate Regional Office (see page 4) to determine if a State Stormwater Permit is also needed prior to construction. Page 1 of 5 SWU-234-052109 Last revised 6/24/14 NCG190000 N.0.1. 6) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 4 4 9 3 7) Services and Activities a) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: (Include a site diagram showing the process areas and location of activities present at this facility.) Facility houses machine shop, Welding shop, warehouse, offices, and boat storage for the USACE Wilmington District. Activities include; dockage and repair to fleet of floating plants (dredges and snag vessel) and survey vessels. b) Check all services and activities offered or allowed at this facility ❑ Transient Slips ❑✓ Engine Repair ❑ Permanent Slips ❑ Dump Station ❑ Lodging ❑ Haul Out ❑✓ Restrooms ❑✓ Pump Out ❑ Restaurant ❑✓ Fueling ❑ Retail Store ❑✓ Boat Ramp ❑ Boat Sales ❑✓ Boat Hand Washing ❑ Trash Collection ❑✓ Vehicle/Equipment Washing ❑ Recycling ❑ Boat Pressure Washing ❑ Fish Cleaning Area ❑✓ Sanding ❑ Charter ❑✓ Sand Blasting ❑ Live Aboard Painting ❑✓ Dry Boat Storage ❑ Boat Building 8) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, boat ramps, lift wells, etc.) convey stormwater from the property? 2 (two) What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? Cape Fear River If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). Not Applicable Receiving water classification (if known): sc List discharge points (outfalls) that convey discharge from the site (both on-site and off-site) and location coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan. Stormwater Outfall No. 1 Latitude (degrees/minutes/seconds): 34'13'41" N Longitude (degrees/minutes/seconds): 77° 5r 14" W Stormwater Outfall No. 2 Latitude (degrees/minutes/seconds): 34° 13' 40" N Longitude (degrees/minutes/seconds): 77'57'16' W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W Page 2 of 5 SWU-234-052109 Last revised 6/24/14 NCG190000 N.O.I. Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W 9) Does this facility 0 a) Have an untreated wastewater discharge? ❑ No R Yes (See Discussion) b) Have a treated wastewater discharge? N No ❑ Yes If yes, list the permit number. c) Have a wastewater discharge from a recycle system? R No ❑ Yes If yes, list the permit number. d) Have a non -discharge permit? 9 No ❑ Yes If yes, list the permit number. e) Discharge wastewater to a municipal wastewater collection system? 9 No ❑ Yes If yes, list the municipality and permit number Note: Stormwater discharge permit NCG190000 does not authorize the discharge of any wastewater. If this site discharges wastewater, you must obtain the appropriate wastewater discharge permit in addition to coverage for stormwater discharges under NCG190000. 10) Does this facility employ any best management practices for stormwater control? ❑ No 0 Yes (Show any structural BMP's on the site diagram.) If yes, please briefly describe: indoor storage when possible, Clean spins immediately, Storage Facility for Paint, Spill containers for barrels 11) Does this facility have a Stormwater Pollution Prevention Plan? 9 No ❑ Yes If yes, when was it implemented? 12) Does this facility use solvents on-site? ❑ No 9 Yes If yes, does this facility have and implement a Solvent Management Plan? P No ❑ Yes (See Discussion) 13) Are vehicle/equipment maintenance activities occurring at this facility (ex. fueling, washing, repair, etc.)? ❑ No 0 Yes 14) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? N No ❑ Yes Page 3 of 5 SWU-234-052109 Last revised 6/24/14 NCG190000 N.O.I. b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? ❑ No 11 Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? P No ❑ Yes d) Is hazardous waste stored in the 100 -year flood plain? ❑ No 11 Yes If yes, include information to demonstrate protection from flooding. e) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: Oil, Diesel fuel (fuel filters), Anti -Freeze, Hydraulic Fluid, Dyna Blue (Solvent), Paint, Rags, Paint thinner How Is material stored: In sealed drums which are placed in spill containment units (See Attached Discussion) Where Is material stored: In spill containments on site until pick up is arranged (See Attached Discussion) How many disposal shipments per year: Varies depending on Repair Yard demand(less than once per month) Name of transport / disposal vendor: Nobel Oil Services Vendor address: 5617 Clyde Rhyne Drive, Sanford, NC 27330 (Headquarters) 15) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: �Xgr 4— '?�vow"j Title- T—a 6)rrXi+/� �CIAI Sy �Sr V ") n (Signature of Applicant) /8 jw'_ ra, (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDEQ Page 4 of 5 SWU-234-052109 Last revised 6/24/14 NCG190000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: EY Check for $100 made payable to NCDEQ (� This completed application and all supporting documents [Z' A site diagram showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater management structures, (c) location of stormwater outfalls (corresponding to which drainage areas), (d) runoff conveyance structures, (e) areas where materials and/or boats are stored, (f) impervious areas, (g) site property lines, (h) boat maintenance, blasting, painting and washing areas, and (i) location of services and activities listed in 7b. Copy of county map or USGS quad sheet (preferred) with location of facility clearly marked on map Mail the entire package to: DEMLR - Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ... (252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 5 of 5 SWU-234-052109 Last revised 6/24/14 m L cts L Q. 1 cn r.L W c J � T J WCL o � a o c J a X O L 0- 4 Q Q ^0 LL NO y 0dgj mo 3N pb dtgsalllL N 0 O O U 00 O N !6 .0 O. f6 2 JG r RECEIVED JUL 23 2013 DENR-LAND QUALITY STORMWATER PERMITTING I 5 q 3 2 � NI D D � I i I I O O O' O Vwr�o" - _f- NRIDGF TI 676 O O OO O O c 1,-- PRIVATE 11-1EIARKINO I I I C l i MO Y I ;STOMGF =' o i OPEN h EGAt 13 2 O STOWAGE I I R STWAOF SNEO WA1 EFNOUSE 00AT I I I IOADINR Dai 1 N KR 1 b PAR—! — O M[KINO ' 6-- B '- 1 9 ^' III I ----------- ------- ---- __--- - __ III MACNINR SNOT WII OUSE [ —_�QFPJCEf PATTERN HOI - - — --- 'I R (MP 0 L L,,z, �-------� o LE A 5 I 4 3 2 T I N I.MNY EN.MEFR DI.TPoCT CORP. OF ENODREER. I; WIWDIOTON,NMTN CAROLINA DwI.RM NY+ Q EAGLE ISLAND A y^ WIIM INGTON, NORTH CAROLINA OrR�nM +ENGINEER REPAIR YARD nnM.R1M .WR 1'� SD' MONRn I� o.R. I. AlMw�l NYS ' 'i L.a1`�♦lam u. � Impervious Areas wV i r a!'x�b' a+ip k n`-fl,�fitl � ,gam ' r � •.g `d i' '(^+tea �„ �� '.P fir. ri,t ; n y 6 _ Irj MRa S.7 y a e, } { N §> z *r a ,... 6 � '•Q,% USACE Engineering Repair Yard Maintenance Areas ry �" 1 t' �� 13A�j1AC33kYm >N, 14 L Ak .. Machine Shop iz rw Material and Boat Storage Paint Storage C. 114 Warehouse + a r.. CapF FFdrM Fry�Or/d/Q�'d� F Down Area Covered boat stora Large Parts Storage Area k �-+74.r Material Warehouse M c �► /tet f r` Services and Activities +�'Boat Wash 5 Ramp . � � "�•.�„ - ...,.fit' ' Restrooms Boat Storage Pump out and Fuel T t (preformed with 1 contracted truck) r.49 Engine Repair, Sanding, Painting, Maintenance w 4L r 40 ' U � Sand Blasting, Parts Cleaning !' Apt i J 1� 6 _ r Stormwater Managment Structures and Runoff Conveyance Structures Small Trenches to direct water flaw 7.. LY Undergro t % Discharge 17�:r.ris .11 ir A t tormwater Managment Structures and Runoff Conveyance Structures :� �� _ � �`� � Remaining Yard s Popes to this area and 40 {, �w. � flows tothe boat ramp w i ..x. / y Y A n 9 t 0, PAM OAMP G NiLUNOUF1.0001.11-11E.— tw NORTH CAROLINA �Y Ir :N�1i —.3117 a ow1• CID PANEL -HX N f T'li e:T:� ui• '' ,.A ,rrt LL. C +-t z P 2 f - * .Li ti y� b ry f LV�;iii£J e FLOOD HAZARD INFORMATION NOTES TO USERS SCALE SEE NS REPORT FORMNEDESCRIMN NS AND NDEF IMP THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTING DOCUMENTATION MEALSO AVAIIABI£ IN DIG TAL FORMATAT HTTP://FRIS. NC. GOV/FRIS -Wtthoa Bau FlaaJElerelba l6FF) Wkh BFEor Depth.,,.e.4. ao.;n. vr. nn SPECNUFLOOD gt8aal0ry Flaadwry HAZARD.- 0.2%Annual CHarcc Flootl Hanrd, Areae a i%Annual Chance M 1,Wi , D1Iw Depth Lessthan One Foalor Mi Drslllege Areas of less than Ona Square MV _ Future Conditbns l%Annual Chance FIOOJ NauM DTH—P-1 grea with Reduced Flaad OHIO Jus la lane FLOODNAIARD See Notes OINFA : 1 Areas Det.,— to ba Oaside the MSS Y Olao Annual CM1ance Floodplain -- Channel, CUAerl,grst"Sewer 0ucrediled of Ptllmi—H1Arend Red GFNERAl ""' "k ,ar Flaodwall SIRUCN.. ........... Non- acemditetl leree, DiFe, or Fbodwall Ngdh Camllw Geodetic Survey OencA-1 Naeorel Geodetic Sane) bench mart np� Conlnclor Est. NCFMP Surrey benchmah �aN�. Cross Senbns wi1M1 1%Annual 0ance Water S.— Ebvation DIFF) n----- Coastal hznsen ----_ Coastal Trametl BasNlne -- ProFRe Baseline IA'tlmgnpM1ic feature alNEn •... umnasnay ��ieta� a�rarr rm�rrxa.+ii�w iwuaWi w -r Mawr rra�rew��e�erxeuw na m rr wrMrmwnrsr.ua. Pmy�rneerrr�msw�rr • � w�xwiirrravlwwMr'i�r�rnrr� wy �wwre �`arsrwrr�r� Yr��41r Y�ir r ....rr ^tAnit a Moderate Wane Anion OIMW16 era lceasl Nprt ®CBRSMa.as" © OUerwl. Pratvaetl Mee I ltmh-500 Teet 1:6,000 o : 0 ADD I'm Malan 0 75 150 300 PANEL LOCATOR MAP NUM0E0 3]20311]OON 01 /540 Ofi/02/08 PAM OAMP G NiLUNOUF1.0001.11-11E.— IE INSURANCE RA MAP tw NORTH CAROLINA �Y w —.3117 a ow1• CID PANEL -HX N � wanrurOH,anaF nmr� sttl x LL. C +-t z MAP NUM0E0 3]20311]OON 01 /540 Ofi/02/08 I� Search Stream Name or Lo t -EI Leland 11-11111*,., ;v,, ,W CJ, B 0 V 111 e GI-V�O 11009 0 0- t N 0"" 8 rite 4"W" 0,yr -1-ItrA,ys Mee, Q7 rT7 M z 0 iv ;77 cz:) - 0 7 F rj..em, F!au Z Ra ✓ Surface Water Classifications: a< Stream fndtx 18-(11) Ic Stream Name CAPE FEAR RR ER Description: From upstream mouth of 'n w Toomers creek to a line across the river from Snows Point (through Snows Marsh) to Federal Point Classification- SC Date of Class, August 81 1981 River Basin: Cape Fear k�lat does this More info C"-- mean Zoom to ... ,. Mal L Lv,o- I GoO., Discussion Wastewater All of the restroom facilities at the USACE Engineering Repair Yard (ERY) 'discharge' into a septic system on site. There is no discharge from this system. Other wastewater from the ERY includes water used for boat washing. Boats are washed using an environmentally friendly cleaner. Other wastewater (from maintenance activities) would be collected with our hazardous waste. Hazardous Waste As indicated the ERY produces/uses several hazardous materials. All Oil, Diesel Fuel, Anti -Freeze, Hydraulic Fluid, Solvent (Dyna Blue), Rags and Paint Thinner are picked up and processed by Nobel Oil Services. These materials are stored in proper containers with additional spill protection devices until retrieved by Nobel Oil Services. Due to the low volume produced/used, pick up times vary and take place less than once per month. Paint is stored in a designated building on site. After use paint is dried in a spill proof container and then properly disposed of. Hazardous Waste Flood Protection As indicated on the FEMA Flood map, the USACE ERY is located within the 100 year Flood Plain. Thus, additional discussion is required regarding protection of hazardous wastes in such an event. The major flood contributor to the ERY is the Atlantic Ocean via the Cape Fear River. A flood event of this magnitude would be caused by the storm surge from a hurricane or an extremely large rain event upstream accompanied by uncommon high tides. In either event, there would be ample warning and time to relocate the hazardous wastes to a safe location. Relocating includes moving the wastes above the 9' expected 100 yr. flood level or scheduling Nobile Oil Services to remove the current waste. Thus, a 100 year flood event would not create any additional concerns regarding hazardous materials. Solvent Plan The only solvent used on site is Dyna -Blue, which is used to clean parts. Once used the solvent and any materials used in cleaning are stored in a proper container inside a spill proof container. These materials are also removed from the site by Nobel Oil Services.