Loading...
HomeMy WebLinkAboutNCG130079_Email RE NCG130079 COC CC to CharMeck SW Services_20180725Georgoulias, Bethany From: Georgoulias, Bethany Sent: Wednesday, July 25, 2018 3:00 PM To: 'Broadway, Chad' Cc: Lucas, Annette; Alexander, Laura; Khan, Zahid Subject: RE: Queen City Transfer Station NCG130079 Hi, Chad, I wanted to close the loop with you on this. We mailed out the special renewal COC to this facility today. You can access a copy in our Laserfiche repository: NCG130079 Renewal COC 2018 Best regards, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethanygeor oulias e ncdenr.gov 512 N. Salisbury Street, Raleigh, NC 27604 (location) 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) Website: http://deq.nc.gov/about/divisions/energy-mineral-land-resources/stormwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Broadway, Chad [mailto:Chad.Broadway@mecklenburgcountync.gov] Sent: Monday, July 09, 2018 9:12 AM To: Georgoulias, Bethany <bethany.georgoulias@ncdenr.gov> Cc: Lucas, Annette <annette.lucas@ncdenr.gov>; Alexander, Laura <laura.alexander@ncdenr.gov>; Khan, Zahid <zahid.khan@ncdenr.gov> Subject: [External] RE: [External]Queen City Transfer Station Hi Bethany, Sorry for the delayed response, I was out of the office last week. Based on the very high concentration of pollutants observed on multiple occasions in the facility's runoff (Fecal = >1.2 million, > 750,000; very high BOD (1,000 mg/L), COD, Copper, and Zinc), my recommendation would be to have them continue with the current monitoring requirements through this 5 -year permit renewal. After that point, it seems like enough data would be present to justify an individual permit or to release them to the typical conditions of the NCG13 permit. The primary issue with the facility is a lack of adequate housekeeping and BMP maintenance, which had led to excessive pollutants on site and basin conditions which have likely led to bacteria replication and contributed to BOD issues. At this point, continuing to require monitoring would be ideal as it should assist them in establishing proper maintenance intervals and procedures, and allows us to evaluate their status outside of our in-house monitoring efforts. Chad Broadway, Environmental Specialist Charlotte -Mecklenburg Storm Water Services Mecklenburg County Water Quality Program 2145 Suttle Avenue Charlotte, NC 28208 704-280-1497 (mobile) chad. broadway@ mecknc.gov http://charlottenc.gov/StormWater Storm Water's WHY statement: We are passionate about making our environment safe and healthy by reducing flood losses and improving water quality for all. Charly tte,W@d;@ n burg 2 � STM Si -WATER Services From: Georgoulias, Bethany[mailto:bethany.georgoulias@ncdenr.gov] Sent: Tuesday, July 03, 2018 12:45 PM To: Broadway, Chad <Chad.Broadway@mecklenburgcountync.gov> Cc: Lucas, Annette <annette.lucas@ncdenr.gov>; Alexander, Laura <laura.alexander@ncdenr.gov>; Khan, Zahid <zahid.khan@ncdenr.gov> Subject: [External]Queen City Transfer Station CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hi, Chad, I just realized that NCG130079 (Queen City Transfer) got renewed with the rest of the batch of NCG13s recently. It was supposed to be with the group of "special" COCs we reviewed at the GP renewal, but we missed doing that. It does not look like anyone has yet requested a copy of the COC, though — it's not in our Laserfiche records for NCG130000 to date. So, unfortunately we let this one slip through without checking to see if it should be renewed under NCG13 as is, or direct the permittee to another path (individual permit). Or, if we needed to provide them special instructions about continuing to monitor the extra suite of parameters. Chad, what would Meck County advise? Let them stay under NCG13 as is, or send a follow up letter to let them know they should continue monitoring the extra parameters? Thanks, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethanygeor oulias e ncdenr.gov 512 N. Salisbury Street, Raleigh, NC 27604 (location) 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) Website: http://deq.nc.gov/about/divisions/energy-mineral-land-resources/stormwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.