Loading...
HomeMy WebLinkAbout20180992 Ver 1_Cover Letter_20180717Kennebec Meadows Subdivision Page 1 of 3 July 17, 2018 US Army Corps of Engineers NC Division of Water Resources Raleigh Regulatory Office 401 & Buffer Permitting Unit Attn: Mr. James Lastinger Attn: Ms. Karen Higgins 3331 Heritage Trade Drive 512 N. Salisbury Street Suite 105 Raleigh, NC 27604 Wake Forest, NC 27587 Re: Kennebec Meadows Subdivision Request for NWP 29 & GC 4139 Action ID # SAW-2017-2370 Sage Project # 2016.57 On behalf of S. Wake Properties, Inc. (applicant and owner) please find attached a complete application and supplemental information requesting written concurrence from the US Army Corps of Engineers (USACE) and North Carolina Division of Water Resources (NCDWR) that the activities associated with the proposed road widening may proceed under Nationwide Permit (NWP) 29 and the associated General Certification (GC) 4139. Please find attached a complete application and supplemental information. Project Summary and Purpose The overall project is a single-family residential subdivision with residential streets and utilities that will connect to existing adjacent roads and utilities in the area. The Project is located in eastern Fuquay-Varina, NC immediately east of Kennebec Road at a point 0.3 mile southwest of the Kennebec Road and Hilltop Road intersection. The purpose of the proposed project is to construct a residential subdivision and associated utilities to meet the demand for housing in this part of Wake County. Project Detail The overall project is a single-family residential subdivision that consists of 48 residential lots, two roads and other associated utilities such as sewer, electric, etc. Residential streets and utilities will connect to existing adjacent roads in the area. The proposed wetland impacts will result from road construction and wetland fill. Heavy equipment Kennebec Meadows Subdivision Page 2 of 3 typically used for utility installation projects (e.g. back hoes, bull-dozers, etc) will be utilized. No recorded federally listed species are located on the project site or within a 1-mile radius according to the NC Natural Heritage Data Base (2018). No structures are located on the subject property. According to the SHPO website, the project is located approximately 250 feet northeast of the Charles Rowland House (WA1127), which was labeled as survey only and ineligible. Project History Most of the project site has been in pasture since at least the mid twentieth century. A riparian buffer determination was not made by NCDWR staff because the applicability of the buffer rules to surface waters on the property were not contested. A site meeting was held with MR. James Lastinger of the USACE on November 7, 2017. A preliminary Jurisdictional Determination has not ben issued but the delineation was confirmed in an email (copy attached) and SAW-2017-2370 corresponds to the project file for this property. Avoidance and Minimization All stream, wetland, and riparian buffer areas on the site have been avoided with the residential site plan. The proposed buffer and stream impacts will result from the extension of an existing culvert under Kennebec Road at a curve in the road. The extended culvert will allow for a wider shoulder needed to increase the safety of the existing stream crossing. Project Impacts No impacts to wetlands are proposed. Proposed stream impacts will result from a culvert extension/roadfill. Permanent stream impacts will total 16 LF and temporary stream impacts required for the culvert installation will total 10 LF. The resulting riparian buffer impacts needed to extend the existing roadway shoulder will total 1,658 ft2 (978 ft2 in Zone 1 and 680 ft2 in Zone 2). No other impacts are proposed. Mitigation No wetland impacts are proposed therefore wetland mitigation is not proposed. The only proposed riparian buffer impacts will result from the widening of an existing perpendicular road crossing that is considered “allowable” therefore no buffer mitigation is proposed. Proposed permanent stream impacts have been minimized to a total of 16 LF. No stream mitigation is proposed. Kennebec Meadows Subdivision Page 3 of 3 If you have any questions, please call me at (919) 559-1537. Sincerely, Sean Clark, PWS Sage Ecological Services, Inc. Attachments: Pre-construction Notification (PCN) Application Form Agent Authorization Map Figure 1-USGS Site Vicinity Map Figure 2-Soil Survey Site Vicinity Map NCNHP report Impact Maps (3 sheets)