Loading...
HomeMy WebLinkAboutNC0049867_Reconnaissance Inspection_20180717WaterResources EWRONMEWAC GUALITY June 17, 2018 Mayor, Danny Gabriel Town of Cleveland Post Office Box 429 Cleveland, NC 27013 SUBJECT: Reconnaissance Inspection Report Cleveland WWTP NPDES WW Permit No. NCO049867 Rowan County Dear Mayor Gabriel: ROY COOPER Gm'eTw? MICHAEL S. REGAN S'eerercm LE D A CLTLPEPPER -kerim Li2-ecfw- The North Carolina Division of Water Resources conducted an inspection of the Cleveland WWTP on 5/29/2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0049867. During the initial compliance inspection numerous deficiencies were noted. A Reconnaissance Inspection was conducted on July 11, 2018 to ensure noted deficiencies have been corrected (see attached inspection report). If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699 or via email at roberto.scheller@ncdenr.gov. SincerelyDocuSigned by: 40101 H P44,44 F161FB69A2D84A3... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENT Cc: WQS Mooresville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement State of North Carolina I Environmental Quality I Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO049867 111 12 I 18/07/11 I17 18 i R i 19 i G i 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I g 71 I tyI 72 I r I 73 I I 174 751 I I I I I I I80 uI I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 09:59AM 18/07/11 14/08/01 Cleveland WWTP 625 Third Creek Church Rd Exit Time/Date Permit Expiration Date Cleveland NC 27013 10:21AM 18/07/11 19/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Paul Stephen Land/ORC/704-642-2165/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Danny Gabriel,PO Box 429 Cleveland NC 27013/Mayor//7042780078 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: - - SQL MRO WQ//252-946-6481/ Roberto Scheller C)91C2A007838943E- 7/16/2018 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Docusigned by: Date 4-0 uo H P41-ft7/17/1 EF161FB69A2D84A3... W. Corey Basinger MRO WQ//704-235-2194/ for CB EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO049867 I11 121 18/07/11 117 18 1 p Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO049867 Inspection Date: 07/11/2018 Other Owner - Facility: Cleveland WWTP Inspection Type: Reconnaissance Yes No NA NE Comment: On Mav 29. 2018 Roberto Scheller of this Office conducted a ComDliance Inspection at the subject facility. During the subject inspection several deficiencies were found and are listed as follows: - Dumpster, for disposal of influent screenings, covers were bent open allowing rain water to reach screenings and creating a vector attraction. - High amount of soilds being maintained under aeration. - Aerobic digester full of sludge. - One of two drying beds being used to stockpile dry sludge. At the time of this site visit on July 11, 2018, all deficiencies noted during inspection have been corrected. Solids have been removed from WWTP and land applied. Facility is wasting to digester to reduce solids load under aeration. Recommendation: Bio-soilds should be removed from WWTP on a regular schedule. Proper balance of activated sludge process is necessary to acheive maximum efficiency to treatment process and comply with Permit limits. Page#