Loading...
HomeMy WebLinkAboutSW3180606_CAVESSON CIVIL SET 2018-05-28_20180627SITE AND DEVELOPMENT DATA JURISDICTION VILLAGE OF WESLEY CHAPEL TAX PARCEL(S): O6O27O05A SITEADDRESS: 703 CHAMBWOOD ROAD ZONING R-40 PROPOSED ZONING R-40 USE CLASSIFICATION RESIDENTIAL TOTAL AREA 42.356 ACRES AREA IN LOTS. 28.15 Acres COMMON AREA 10.64 Acres RIGHT-OF-WAY 3.553 Acres LINEAR FOOTAGE OF STREETS 2,978 MINIMUM FRONT SETBACK 50' MINIMUM CORNER/SIDE SETBACK 15' MINIMUM REAR SETBACK 40' CAVESSON WAY 9+50 TO 18+32.25 MINIMUM LOT SIZE 40,000 SQ. FT. MINIMUM LOT WIDTH 120' TRAVERS COURT 9+00 TO 11+46 DISTURBED AREA 9.98 ACRES E A G L E E N G I N E E R I N G FIRM L I CENSE # C-0873 2013A Van Buren Avenue P.O. BOX 551 Indian Trail, NC 28079 Alpharetta, GA 30009 (704) 882-4222 (678) 339-0640 www.eagleonline.net THESE PLANS ARE CONSISTENT WITH THE PRELIMINARY PLAT APPROVAL GRANTED BY THE WESLEY CHAPEL VILLAGE COUNCIL FOR CAVESSON ON OF .2018. JOHN H. ROSS, P.E. DATE I HEREBY CERTIFY THAT THE PRELIMINARY PLAT SHOWN HEREON HAS BEEN FOUND TO COMPLY WITH THE SUBDIVISION REGULATIONS OF THE VILLAGE OF WESLEY CHAPEL, NORTH CAROLINA ON THIS OF .2018. MAYOR, VILLAGE OF WESLEY CHAPEL, N.C. PROJECT ENGINEER: JOHN H. ROSS, P. E. STREET ADDRESS: 2013A VAN BUREN AVENUE CITY, STATE, ZIP PHONE: FAX PREPARED FOR: STREET ADDRESS: CITY, STATE, ZIP: PHONE: CONTACT: NO. DATE BY ISSUE INDIAN TRAIL, NC 28079 704.882.4222 704.882.4232 BOWMAN DEVELOPMENT 13815 CINNABAR PL HUNTERSVILLE, NC 28078 (704)875-9704 EXT. 108 TJ PECORAK a``APF � N CARO 14, f11 0 071. <�'L EAGLE n ENGINEERING, Z m INC. O �,A No. C-0873 �1iih F OF AU�0 AR0 149 _ IN 5/28/18 Know what's below. Call before you dig. CALL 1.800.632.4949 OR 811 WWW.NC811.ORG NC ONE -CALL CENTER ITS THE LAW! CAVESSON CONSTRUCTION PLANS VILLAGE OF WESLEY CHAPEL chi f I '�� �1 @Qr1 wecoi ngk.b SITE Fin ti. fNu10 no VICINITY MAP 1 "=2000' 5O'R/W - r - j STREET TREE5' DE 5' S E STREET TREE (50'C 1.50' WAL 5' 2.5' 11 ' LANE 11 ' LANE 2.5' S' ALK (50' C -C) 3� 4" WATER METEF 4" SEWER LATERAL 12 -30" STD. C & G 2.0% 6" ABCC)___STORM DRAIN PIPE 2' MIN. COVER 2.0% WATERMAIN 8" SANITARY SEWER 6' OFF BOC 3'MIN. COVER LOCAL RESIDENTIAL TYPICAL STREET SECTION 27'BC/BC / 50' ROW SCALE: NOT TO SCALE ABC SECTION 60.110-D STREET STANDARDS Sheet List Table Sheet Number Sheet Title Sheet Description C-0.0 COVER SHEET C-1.0 EXISTING CONDITIONS SURVEY C-2.0 PRELIMINARY PLAT R-40 RESIDENTIAL C-2.1 ENTRANCE SIGHT DISTANCE C-3.0 EROSION CONTROL PHASE 1 C-3.1 EROSION CONTROL PHASE 2 C-3.2 SOILS MAP C-3.3 CAVESSON WAY 0+00 TO 9+50 C-3.4 CAVESSON WAY 9+50 TO 18+32.25 C-3.5 TRAVERS COURT 0+00 TO 9+00 C-3.6 TRAVERS COURT 9+00 TO 11+46 C-3.7 DRY DETENTION BASIN PLAN C-3.8 STORM DRAINAGE TABLE C-4.0 OVERALL UTILITY PLAN C-4.1 SS -A PLAN AND PROFILE STA: 0+00 - 11+22.77 C-4.2 SS -A PLAN AND PROFILE STA: 11 +22.77 - END C-4.3 SS -B PLAN AND PROFILE STA: 0+00 - END C-4.4 SS -C PLAN AND PROFILE STA: 0+00 - END C-5.0 SITE DETAILS 1 OF 2 C-5.1 SITE DETAILS 2 OF 2 C-5.2 EROSION CONTROL DETAILS (1 OF 3) C-5.3 EROSION CONTROL DETAILS (2 OF 3) C-5.4 EROSION CONTROL DETAILS (3 OF 3) C-5.5 UTILITY DETAILS 1 OF 3 C-5.6 UTILITY DETAILS 2 OF 3 C-5.7 UTILITY DETAILS 3 OF 3 C-5.8 CONSTRUCTION NOTES 2. ALL NEW STREETS MUST HAVE 10 INCHES OF ABC OR 5 INCHES OF B25.00 ii" SURFACE COURSE, TYPE SF9.5B (ASPHALT CONCRETE BASE COURSE) AND 2 LIFTS OF S9.513 (ASPHALT CONCRETE SURFACE COURSE) WITH A MINIMUM DEPTH OF 1.5 INCHES FOR EACH LIFT. THE FIRST 1.5 -INCH LIFT OF S9.5B MUST BE SURFACE COURSE, TYPE SF9.5B PLACED IMMEDIATELY UPON THE PROPERLY PREPARED BASE COURSE. 1 THE FINAL 1.5 -INCH LIFT OF S9.513 SURFACE COURSE MUST BE PLACED ON THE INTERMEDIATE SURFACE 10" COMPACTED AGGREGATE BASE COURSE COURSE ONCE THE DEVELOPMENT OR APPROVED PHASE OF THE DEVELOPMENT HAS RECEIVED 75% OF THE OCCUPANCY PERMITS FOR THE DEVELOPMENT OR APPROVED PHASE OF DEVELOPMENT. ALL KNOWN BASE COURSE AND INTERMEDIATE COURSE FAILURES MUST BE REPAIRED BEFORE APPLICATION OF THE FINAL 1.5 -INCH LIFT OF ASPHALT SURFACE COURSE. EEI Project Number: 6198 MISCELLANEOUS NOTES NO USGS MONUMENTATION WITHIN 2000' OF SITE. GRID POSITIONS WERE DETERMINED USING A TRIMBLE 5800 GNSS GPS RECEIVER UTILIZING THE NORTH CAROLINA GEODETIC SURVEY VRS NETWORK. ALL COORDINATES AND BEARING SHOWN ARE BASED ON NAD 83/2011. ELEVATION DATUM IS REFERENCED TO NAVD88. CONTOUR INTERVAL = ONE FOOT. TOPOGRAPHIC DATA WAS PROVIDED BY AVIOIMAGE, INC. AND IS GENERATED FROM AERIAL PHOTOGRAPHY. EEI PROVIDED AERIAL GROUND CONTROL AND SUPPLEMENTED WITH FIELD SURVEY IN AREAS OF DENSE FOLIAGE. TREES SHOWN ARE SUBJECT TO ERROR IN KIND. AREAS COMPUTED USING COORDINATE GEOMETRY. IRON REBARS AT ALL PROPERTY CORNERS UNLESS OTHERWISE NOTED. DEED REFERENCE: AS SHOWN. ALL ADJOINER PROPERTY OWNER INFORMATION IS TAKEN FROM CURRENT DEEDS AND TAX RECORDS AND ARE CONSIDERED "NOW OR FORMERLY". RAW ERROR OF CLOSURE: 1:10,000+. BOUNDARY TRAVERSE WAS ADJUSTED USING THE LEAST SQUARES METHOD. OTHER UNDERGROUND UTILITIES MAY EXIST BUT THEIR LOCATIONS ARE NOT KNOWN. THIS SURVEY IS OF AN EXISTING PARCEL OR PARCELS OF LAND. ALL DISTANCES SHOWN ARE HORIZONTAL GROUND DISTANCES. A PORTION OF THE PROPERTY SHOWN HEREON IS LOCATED WITHIN A SPECIAL FLOOD HAZARD AREA AS SHOWN ON F.E.M.A. FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 3710449500JX, EFFECTIVE DATE OCTOBER 16, 2008. UTILITY NOTES THE LOCATION OF UTILITIES SHOWN HEREON ARE FROM OBSERVED EVIDENCE OF ABOVE GROUND APPURTENANCES ONLY. THE SURVEYOR WAS NOT PROVIDED WITH UNDERGROUND PLANS TO DETERMINE THE LOCATION OF ANY SUBTERRANEAN USES. THIS SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN HEREON COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THERE IS NO CERTAINTY OF THE ACCURACY OF THE INFORMATION AND IT SHALL BE CONSIDERED IN THE LIGHT BY THOSE USING THIS SURVEY. UTILITIES AND STRUCTURES NOT SHOWN MAY BE ENCOUNTERED. THE OWNER, HIS CONSULTANTS AND HIS CONTRACTORS SHALL HEREBY DISTINCTLY UNDERSTAND THAT THIS SURVEYOR IS NOT RESPONSIBLE FOR THE SUFFICIENCY OF THE UNDERGROUND UTILITY INFORMATION PROVIDED HEREON, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. Know what's beIow. Call before you dig. CALL 1.800.632.4949 OR 811 WWW.NC811.ORG NC ONE -CALL CENTER ITS THE LAW! CHARLES B. BAUCOM TAX PIN: 06-0027-048 TRACT 5 PLAT CAB. K, FILE 722 NOW OR FORMERLY BLAIR BURKE BK. 7100-160 TAX PIN: 06-030-014A TRACT 2 PLAT CAB. N, FILE 524 NOW OR FORMERLY 1� A �S JACK CASE / BK. 7071-403 / TAX PIN: 06-030-014B / LEGEND OF SYMBOLS & ABBREVIATIONS TRACT3 / PLAT CAB. N, FILE 524 NOW OR FORMERLY EIP -EXISTING IRON PIPE EIR -EXISTING IRON REBAR 1 518" EIR NIR - NEW IRON REBAR S.T. - SIGHT TRIANGLE / M.B.S. - MINIMUM BUILDING SETBACK / P.S.D.E. - PUBLIC STORM DRAINAGE EASEMENT S.S.E. - SANITARY SEWER EASEMENT / SSMH - SANITARY SEWER MANHOLE / R/W - RIGHT OF WAY / .25" EIP P.S.S.E. - PRIVATE SANITARY SEWER EASEMENT / GPUE - GENERAL PUBLIC UTILITY EASEMENT�°� / C.P. -COMPUTED POINT DAVID E. BALLENGER ECM EXISTING CONCRETE MONUMENT BK. 602-107 E.P.K. - EXISTING P.K. NAIL TAX PIN: 06-030-002A �% NOW OR FORMERLY 4F / / - HANDICAPPED PARKING / �txA' / h ® TRANSMISSION TOWER UTILITY POLE MICHAEL DAVIS - - - -GAS- - - —GA& - UNDERGROUND GASLINE TAX PIN: 06-030-002B NOW OR FORMERLY P -OH -OVERHEAD UTILITY LINE _ - - -SS SANITARY SEWER LINE _ Q SANITARY SEWER MANHOLE FIRE HYDRANT p3 S1 0 `L WATER VALVE o - - WATER WELL ■ YARD INLET/ AREA DRAIN SSMH RAILROAD TRACK \ 314" EIP \RIM 544.7 ® MONITORING WELL v ❑E ELECTRIC BOX/TRANSFORMER �\ 3 CURB INLET \ \ 0 3 ----SD— - STORM DRAIN - - -w - WATERLINE S68 T 3----x----x- -FENCE LINE / -ZONING LINE / o / 3 / — — — —T -UG — — — T -UG - UNDERGROUND TELEPHONE / SPECIAL FLOOD HAZARD AREA (ZONE AE). / D 1 % ANNUAL CHANCE FLOOD ZONE. / / REGULATORY FLOODWAY / X 0 +GJv/ ( / / 1.25" Elp �31OAK / I / CHAMBWOOD ROAD - PUBLIC R/W I APPROX. LOCATION OF 8" PVC WATERMAIN --w--- -w--- -w----w-- —w----w----w--- ------- W_ —w -------w--- _ ---w-- BENTON EDWARDS „E BENTON EDWARDS BK. 920-782 N24°52'55 TAX PIN: 06-0027-043 B T ACT 17 NOW OR FORMERLY g90� TRACT 1 - LANDON MUNDY PLAT CAB. D, FILE 583 , pAD TAX PIN: 06-0027-044 / / PAVED R BK. AC 413 NOW OR FORMERLY / 12"CEDAR / i UN' TRACT2 I -_ -� PLAT CAB. D, FILE 583 10_ `' CEDAR TAX PIN: 06-0027-045 1"EIR NOW OR FORMERLY N:455880.18 E:1497588.94 NAD 83/2011 JUDITH B. ZIMMER TAX PIN: 06-0027-049A BK. 1747-130 PART OF TRACT 6 WIRE FENCE 10" CEDAR 12" CEDAR 10" GUM `_ PLAT CAB. K, FILE 722ia NOW OR FORMERLY (TYP.) 11" ELM 10"GUM 12" CEDAR 10" CEDAR 014" CEDAR 10" CEDAR �O� cad 16" CEDAR O p0 QD19"OAK \ 1, 845,045 sq. ft. 42.356 acres 19 CEDAR M � O m Z O / 11"PINE MARKJ. ROSENBLUM 11"CEDARAR 11 CEDAR / THIS IS TO CERTIFY THAT ON THE 14TH DAY OF MARCH, 2018, AN & KATE K. ROSENBLUM ���", S 10"ELM k\ BK. 550, PG. 851 \ TAX PIN: 06-027-005A 12" PERSIMMON � �� 16" ELM \ 12" CEDAR 11" WILD CHERRY FOR LAND SURVEYING IN NORTH CAROLINA BOARD RULE .1600 ( 21 EXm, \ \ \k 11"CEDARA_ SSMH-��- \ 10" CEDAR P DAR \ \ \X \ 10" CEDAR 1/2" NIR 10" CEDAR ' /— AT 0+20.00' 13" CEDAR .S \ k\ EX.18" S . 244.50' \ \ 112" EIR 9V \ • . S30°25 18 IO q �s8�-�_ S30� 1 "W • \10" 17" CEDAR CEDAR - 296.41' 17" C�E6)�iR 12" WILD CHERRY 16" CEDAR k\ ,11" WILD CHERRY x 14" CEDAR \ \k \ 13" CEDAR . - 17' CEDAR 24" OAK 12"CEDAR 12" PINE . ' 13" PINE " U1 14" PINE 11 PINE 13" CEDAR —� 12" PINE tv'O 13" CEDAR 13" PINE �_ ? 10" CEDARm 13" PINE v 10" PINE N POND 12" CEDAR 12" PINE 10"CEDAR 14" PI 13" PI 12" CEDAR e Vs ., VIM Milli11110 ..L +6lAi 6.@'" 11 " OAK GROVE OF (19) PINE TREES MIN. SIZE 10" DBH 10" TREE 112" EIR GROVE OF (56) TREES MIN. SIZE 10" DBH SPECIES VARIES \3 � 112" NIR 51 269.12 MARK J. ROSENBLUM & KATE K. ROSENBLUM BK. 550, PG. 851 TAX PIN: 06-027-005A NOW OR FORMERLY IF -- ZONING INFORMATIONI I ACCORDING TO THE UNION COUNTY GEOGRAPHIC INFORMATION SYSTEM (GIS) ON MARCH 14, 2018, THE SUBJECT PROPERTY IS ZONED "R-40" BECAUSE THERE MAY BE A NEED FOR INTERPRETATION OF THE APPLICABLE ZONING CODES, WE REFER YOU TO THE UNION COUNTY ZONING DEPARTMENT AND THE VILLAGE OF WESLEY CHAPEL ZONING DEPARTMENT. °I''-- EPK 112" EIR 112" EIR N:456688.13 E:1497963.67 NAD 83/2011 JOHN H. HUCKERT, JR. BK. 6354, PG. 141 �o a TAX PIN: 06-027-006 c I NOW OR FORMERLY �o a 112" EIR i xl JUNE MOORE DOROTHY MOREE BK. 6403, PG. 115 PLAT D-520 TAX PIN: 06-027-010 NOW OR FORMERLY 112" EIR 12" CEDAR FEMA X -SECTION #464 12" CEDAR BFE = 552.2 \ f-10"CEDAR 42" OAK 11"CEDAR 101,PINE\ N47-32,0 18" CEDAR 15"CEDAR 10" CEDAR �'� 164.8-112" EIR —� 13" OAK — TIE LINE . t 14" CEDAR 10" WILD CHERRY _ POND CO 12" CEDAR (9Cn ' tai W ` , • � o . 11 " CEDAR 11 " CEDAR m \ 16" CEDAR �� \ V 10" GUM 10" TREE 10" MAPL.( 10" CEDAR \ o�10" CEDAR 10" CEDAR - 1 /2" NIR 16" OAK tt"CEDAR 10"P E \� 1 OAK , 11 CEDAR 10" CEDAR / 0" PINE 6" OAK 011"CEDAR 11"CEDAR ® X 11"CEDAR �� 0 11"CEDAR 10" CEDAR _ —X — 10" CEDAR C o 10" CEDAR `, 1/2" NIR / POND LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY EAST FORK OF TWELVE MILE CREEK GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. 1.25" EIP 1 " EIP 1 ® 518" EIR I I I I I I I LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY I �I II X m C� 0 0 (z:1 Q') Q M O WV Cl) Z m M U Q c LLo — W 0 � U � o Z V N 0 , — LL �z 00 (10 a0 M 'p o = N LU J � m U LU U M � O m Z O / tT I" ELM 10" AK 1 / 11 CEDAR / THIS IS TO CERTIFY THAT ON THE 14TH DAY OF MARCH, 2018, AN (.01 ���", S PROPERTY SHOWN ON THIS PLAT, AND THAT THE BOUNDARY LINES 1 — '- fit RIM 550.19 O FOR LAND SURVEYING IN NORTH CAROLINA BOARD RULE .1600 ( 21 EXm, NCAC 56 ) AND THE ERROR OF CLOSURE FOR THIS PARCEL DOES 11"CEDARA_ SSMH-��- SURVEY �OR 20 SECONDS TIAM THE SQUARE ROOT OF THE P DAR RIM 4 —� 1/2" NIR 10" CEDAR ' /— AT 0+20.00' 13" CEDAR .S EX.18" S . 13"CEDAR • . 18 IO q �s8�-�_ S30� 1 "W • CEDAR 296.41' LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY EAST FORK OF TWELVE MILE CREEK GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. 1.25" EIP 1 " EIP 1 ® 518" EIR I I I I I I I LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY I �I II X m C� 0 0 (z:1 Q') Q M O WV Cl) Z m M U Q c LLo — W 0 � U � o Z V N 0 , — LL �z 00 (10 a0 M 'p o = N LU J � m U LU U M � O m Z O O � V / i V SURVEYORS CERTIFICATION m THIS IS TO CERTIFY THAT ON THE 14TH DAY OF MARCH, 2018, AN ACTUAL SURVEY WAS MADE UNDER MY SUPERVISION OF THE PROPERTY SHOWN ON THIS PLAT, AND THAT THE BOUNDARY LINES 1 — AND IMPROVEMENTS, IF ANY, ARE SHOWN HEREON, EXCEPT AS NOTED. THIS PLAT MEETS THE MINIMUM STANDARDS OF PRACTICE O FOR LAND SURVEYING IN NORTH CAROLINA BOARD RULE .1600 ( 21 Z NCAC 56 ) AND THE ERROR OF CLOSURE FOR THIS PARCEL DOES RUSSELL L. WHITEHURST, PLS PROFESSIONAL LAND SURVEYOR LICENSE NO. L-3661 DATE T ~ U w � z CL( z = z W zO oCL LLI J J Z 0 O z w m _W Uj LLW 7 O O L p �Cr�o z LU O U) O _ z w J � m U LU U M � O m Z O O � V / i V SURVEYORS CERTIFICATION N w THIS IS TO CERTIFY THAT ON THE 14TH DAY OF MARCH, 2018, AN ACTUAL SURVEY WAS MADE UNDER MY SUPERVISION OF THE PROPERTY SHOWN ON THIS PLAT, AND THAT THE BOUNDARY LINES 1 — AND IMPROVEMENTS, IF ANY, ARE SHOWN HEREON, EXCEPT AS NOTED. THIS PLAT MEETS THE MINIMUM STANDARDS OF PRACTICE � FOR LAND SURVEYING IN NORTH CAROLINA BOARD RULE .1600 ( 21 W NCAC 56 ) AND THE ERROR OF CLOSURE FOR THIS PARCEL DOES NOT EXCEED (1) FOOT 10,000 LINEAR FEET OF PERIMETER Q SURVEY �OR 20 SECONDS TIAM THE SQUARE ROOT OF THE RUSSELL L. WHITEHURST, PLS PROFESSIONAL LAND SURVEYOR LICENSE NO. L-3661 DATE T ~ U w � z CL( z = z W zO oCL LLI J J Z 0 O z w m _W Uj LLW 7 O O L p �Cr�o z LU O U) O _ z w J � m U LU U M � O m Z O O � V O o V m � N w v , 1 — _ � O o W m Z cD Q m ESS// LLu� WH\'4, N118 Sheet WESLEY OAKS HOA 50'R/W BK. 4384-523 STREET TREE 5' qDEE 5' S E STREET TREE TAX PIN: 06-048-323 1.50' WA5' 2.5' 11' LANE 11' LANE 2.5' 5' ALK (50' C -C) NOW OR FORMERLY (50'C C) ZONE:R-40 ROY& MELISSA HALL USE: COMMON AREA BK. 4461-613 PROJECT ENGINEER: 30" STD. C & G 3•� 2013A VAN BUREN AVENUE CITY, STATE, ZIP iz" 2.0% 2.0% PHONE: 704-882-4222 FAX: 866-775-0329 J" WATER ME ER JOHN H. ROSS 4" SEWER6" ABC LATERAL STORM DRAIN PIPE STREET ADDRESS: 2' MIN. COVER CITY, STATE, ZIP WATERMAIN 8" SANITARY SEWER PHONE: 6' OFF BOC EMAIL: XMIN. COVER LOCAL RESIDENTIAL DEVELOPER: TYPICAL STREET SECTION STREET ADDRESS: 27'BC f ROW CITY, STATE, ZIP Bo roSCALE/50' SCAL PROJECT ENGINEER: JOHN H. ROSS, P.E. STREET ADDRESS: 2013A VAN BUREN AVENUE CITY, STATE, ZIP INDIAN TRAIL, NC 28079 PHONE: 704-882-4222 FAX: 866-775-0329 CONTACT: JOHN H. ROSS EMAIL: JROSS@EAGLEONL INE. NET OWNER: MARK & KATE ROSENBLUM STREET ADDRESS: 703 CHAMBWOOD RD CITY, STATE, ZIP MONROE, NC 28110 PHONE: 704-111-1111 EMAIL: EMAIL DEVELOPER: BOWMAN DEVELOPMENT STREET ADDRESS: 13815 CINNABAR PLACE CITY, STATE, ZIP HUNTERSVILLE, NC 28078 PHONE: 704-875-9704 X108 CONTACT: TJ PECORAK EMAIL: PECORAK@MSN.COM GENERAL NOTES: • ALL LOTS ARE OUTSIDE OF 100 YEAR FEMA FLOODPLAIN. • ALL OPEN SPACE TO BE PASSIVE AND DEDICATED TO A H.O.A. • THIS DEVELOPMENT IS A "LOW IMPACT" SITE WITH APPROXIMATELY 15% OF NEW CONSTRUCTION (INCLUDING HOUSES & DRIVEWAYS) TO BE IMPERVIOUS. 1 DAVID E. BALLENGER BK. 602-107 TAX PIN: 06-030-002A \ / NOW OR FORMERLY \ ZONE: R-40 \ USE: VACANT \ \\ 3 J .41,11111W L�� r� / / / MICHAEL DAVIS TAX PIN: 06-030-002B NOW OR FORMERLY ZONE: R-40 USE: VACANT I TAX PIN. 06-027-042 / NOW OR FORMERLY / MARLENE LYONS ZONE: R-40 TRUSTEE USE: RESIDENTIAL BK. CS13-496 1 1 TAX PIN: 06-027-042A _ NOW OR FORMERLY 1:1 ` ZONE:R-40 Cy USE: RESIDENTIAL RICHARD KAPITAN �BK. 6012-624 �10OD TAX PIN: 06 027-004B ABC SECTION 60.110-D STREET STANDARDS Q �i 0 RICHARD KAPITAN NOW OR FORMERLY 2. ALL NEW STREETS MUST HAVE 10 INCHES OF ABC OR 5 INCHES OF B25.00 Ap _ BK. 6012-624 ZONE:R-40 1 SURFACE COURSE, TYPE SF9.5B (ASPHALT CONCRETE BASE COURSE) AND 2 LIFTS OF S9.5B (ASPHALT CONCRETE SURFACE COURSE) W_ - B��C _ j TAX PIN: 06-027-004B USE: RESIDENTIAL WITH A MINIMUM DEPTH OF 1.5 INCHES FOR EACH LIFT. THE FIRST 1.5 -INCH LIFT OF S9.5B MUST BE W- _ �/�/ NOW OR FORMERLY 1 SURFACE COURSE, TYPE SF9.5B PLACED IMMEDIATELY UPON THE PROPERLY PREPARED BASE COURSE. BENTON EDWARDS ` w_ _ ` ZONE:R-40 THE FINAL 1.5 -INCH LIFT OF S9.5B SURFACE COURSE MUST BE PLACED ON THE INTERMEDIATE SURFACE BK. 734-397 w_ _ USE: RESIDENTIAL 10" COMPACTED AGGREGATE BASE COURSE COURSE ONCE THE DEVELOPMENT OR APPROVED PHASE OF THE DEVELOPMENT HAS RECEIVED 75% OF TRACT 1 ` _w_ THE OCCUPANCY PERMITS FOR THE DEVELOPMENT OR APPROVED PHASE OF DEVELOPMENT. ALL KNOWN- PLAT CAB. D, FILE 583 BENTON EDWARDS � �W_ BASE COURSE AND INTERMEDIATE COURSE FAILURES MUST BE REPAIRED BEFORE APPLICATION OF THE TAX PIN: 06-027-044 BK. 920-782 FINAL 1.5 -INCH LIFT OF ASPHALT SURFACE COURSE. / LANDON MUNDY NOW OR FORMERLY TAX PIN: 06-027-043 - _ _ BK. 6900-413 ZONE:R-40 NOW OR FORMERLY w- - ® ------- TRACT2 USE RESIDENTIAL -w- - _ W_ PLAT CAB. D, FILE 583 rr- - - TAX PIN: 06-027-045 0 Lu o NOW OR FORMERLY �� 214.84' 140.56' 120.00' 123.50 150.00' ZONE: R-40 y`o. 41 ° USE RESIDENTIAL-_ l \ LOT: 5 F 2I IS IE CO OPEN SPACE : 120 LOT: 1 9,596 sq .t \ 59,984 sq ftI I I I 43,441 sq ft 0.22 ac h� 1.38 ac 1.00 ac t ti� I I I I N I JUDITH B. ZIMMER / LOT: 4 LOT: 2 m TAX PIN: 06-027-049A i� N LOT: 3 co BK. 1747-130 LOT: 6 43,306 sq ft 40,422 sq ft � 41,374 sq ft N 56,352 sq ft w\ M 0.99 ac M 0.93 ac M 0.95 ac co PART OF TRACT 6 1.29 ac o PLAT CAB. K, FILE 722 \ NOW OR FORMERLY ZONE: R-40 USE RESIDENTIAL I - 20'PSDE 9 �o \ LOT:7 \ 4 L 19.6 96.73' I 120.00' 53.90' -7 / CHARLES B. BAUCOM c9 \ 40,948 0.94 asq cc ft \ %10 \ \ 'L� • -. TAX PIN: 06-027-048 - TRACT 5 \ 1.62'-1 8$ S24°48'32"W 270.63' L I o^o PLAT CAB. K, FILE 722 p wA� 09 - p �r I NOW OR FORMERLY ���o \�/ \ `�9 \ \ p L=24.605.65' 120.00' 54.99' L =6 7 9 I ZONE:R-40 \ LOT: 8 s 22 USE RESIDENTIAL \ 40,961 sq ft \\ \ \ � 0.94 ac LOT: 28 _� I 43,358 sq ft P20' - u� 1.00 ac N LOT: 9 \ \ \\ 9 BBURKE 40,974 sq ft LOT: 24 BKK..I I ( 7 p 7100-160 ti�p�' 0.94 ac \ O� <41,998 sq ft LOT: 27 - / TAX PIN: 06-030-014A Q o \ ^�0 : 0.96 ac LOT: 25 LOT: 26 40,130 sq ft M TRACT 2 STREET LIGHT 41,930 s ft 0.92 ac p / A 41,071 sq ft r: q d N PLAT CAB. N, FILE 524 N \o (TYP.) 60 `•' 0.94 ac M 0.96 ac M �. NOW OR FORMERLY \\ LOT: 10 \ / X60 ZONE:R-40 0� \\ 40,987 q f t \ \ \ \`-3 0.94 a USE: VACANT 2• \ \� 06 6 � � I I 1�� LOT : 23 \\ \ 15'SB 1 LOT: 11 �1� 40,248 sq ft 4 1, 000sq ft \\ ,�_j p�6. ' 0.92 ac \ g7 5g' JACK CASE 59' L=93.45 \\ 0.94 ac �\ 9 , 3 \ \ BK. 7071403 00 0 \ �y0 / / \ \\ 5.32' 52.90' 120.78' o TAX PIN: 06-030-0148 r'� \ 65.50' 56.34' TRACT 3 _ �� \ / opo PLAT CAB. N, FILE 524 90 \ RS9SLOT: I� L-1319.27 NOW OR FORMERLY 11 '' ' LOT : 12 155,451 sq ft \\ 'G r. 5 , / \ \ \ / oo° � / tm ZONE:R-40 h \ 50,858 sq ft \ �/ Ao- s� 3.57 ac LOT . C 22 \ USE: VACANT a 1.17 ac p0 0 - o� I o Q; \ _ / 48,262 sq ft r -10 6' _ r' \> � 1.11 ac ' 53 LOT: 13 \ L-28.90 1.94' 131' 40,708 sq It L=53.52 �� 16.65' , 0.93 ac L=20.01 \ ESMT. \/ 92 L=39.27 \�� / \ i 24.74 1p. / 0 91' 9 LOT: 14 �o' • 01L=62.75 mi 40,569 sq ft 9 1y2LOT: 21 0.93 ac i \ 5g "� 40,291 sq ft N o 20' PSDE 0.92 ac 0 / O ^ M / p M OPEN SPACE rn' L=15.08 71,807 sq ft / 0 1.65 ac N 15244.92', o- / 40,040 sq ft_ 0.92 ac g� \ STREET LIGHT v o MARK J. ROSENBLUM & KATE K. ROSENBLUM BK. 550, PG. 851 TAX PIN: 06-027-005A NOW OR FORMERLY ZONE: R-40 USE RESIDENTIAL V LOT: 20 / / I P. S. D. E. ' 20� \ _ 43,137 sq ft \ 0.99 ac by a\ \ OPEN SPACE \ G� o- L p I / 391,321 sq ft / G� LOT: 16 / 8.98 ac / 40,240 sq ft \ m \ \ / / 0.92 ac \ LOT : 19 \ 5 13 52.91' � \ 45, 8 ac ft \ \\ HV -3 TN ON PENINSULA � N� `s<p / LOT: 17 I M rn \ \ EX. 20' r \ .� / 40,071 sq ft \ S.S. ESMT.I I 0.92 ac I c�, LOT : 18 40,073 sq ft ZONE.AE i yl2o'� 44.411 0.92 ac 210.32' 254.73' - '65(0, S.S. I ESMT. / , , , ��s` , a6 �r I EX S 18' Z� 5j I SS'- EX.1 ' S. S. ��- . mss- - _ _ �� _ SS �� FLOODWAY _EAST FORK OF _ I TWELVE MILE CREEK - -� FEMA FLOOD AREA FIRM PANEL 4495J I I LOVELL FAMILY LIMITED PARTNERSHIP I BK. 1488, PG. 821 I l(j TAX PIN: 06-027-007 111 NOW OR FORMERLY I ZONE.AE Ll UNINCORPORATED N I m UNION COUNTY ZONE: R-40 W I - USE: VACANT -w- v _ y o• / / / / / STREET TREE (TYP.) STREET LIGHT (TYP.) JOHN H. HUCKERT, JR. / BK. 6354, PG. 141 N SPACE: 107 TAX PIN: 06-027-006 OPEN S ft NOW OR FORMERLY 0.20 ac ZONE: R-40 I USE RESIDENTIAL / JUNE MOORE / DOROTHY MOREE / BK. 6403, PG. 115 PLAT D-520 TAX PIN: 06-027-010 NOW OR FORMERLY ZONE: R-40 \ USE RESIDENTIAL LOVELL FAMILY / LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY / UNINCORPORATED UNION COUNTY / Curve Table Curve # Length Radius Delta Chord Bearing Chord Distance C1 450.610 300.000 086.0601 S 18 ° 13'17"E 409.43 C2 196.312 250.000 044.9914 S2°18'47"W 191.31 C3 58.389 300.000 011.1514 S 14 °36 25"E 58.30 C4 154.432 175.000 050.5617 S84°54'06"E 149.47 C5 429.407 175.000 140.5897 S10°4026"W 329.50 II / J GR0HI SCAL 0 100' 200' ( IN FEET ) 1 inch = loo ft. rn 0 0 Li oM 0 L0 c0 0 WV m � M Z W U Q W Cf) 0 �i � � a� z U m D �QNN U_ Z N 7 m-� c4 WW > Q) Q c4 M a o � N W X Z) m Cr J W � z m o J m U \CL z T D 111W N Q O � Z Y W C Q W J U u ZCL z z LUoLU Qw J J m J U� 0z� w w LU (f) > QQ� Q `` z Q) Uj C)� QLOUjz J J CO •�11' CAR 0O'C. s /ter` •! • �N G I N •FIOUSZ��''\ �; 5/28/18 Sheet C-2.0 X m Cr J W � z m o J \CL z T 111W N Q � Qo r^ v, Y N m � 'J Q o w 0 CL z J W Y O z m Q w Z c Q m U) •�11' CAR 0O'C. s /ter` •! • �N G I N •FIOUSZ��''\ �; 5/28/18 Sheet C-2.0 OBJECT h -5+00 -4+00 -3+00 -2+00 -1+00 0+00 1+00 2+00 3+00 4+00 -4+00 — — -3+00 -2+00 -/+UO N24°5255'E 890.62 I I I OPEN $PACE : 12 9,596 sq ft !, I 0.22 ac LOT:i I 43,441 sq ft 1.00 ac I i I i I I I I I 10' OFF EDGE OFPAVEMENT I � O WLo U 3+00 10 =CT HEIGHT. -Y Mo • I �•'�III VERTICAL SCALE ( IN FEET ) 1 inch = 4' ft. 0 I I GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. W rn 0 rn �- z 0 Lo o � m Q L o 0 z Z m f M m O W — Z U d W Q - W W N � I11 W z �, U� a) �0 aoi Yu Q� JQNN z z LL N Z00 Z m 00 c0 WW YO W m Q �a o� N � W 2 rn �- z m m Q W z m m O W — Z d z 0 J W � CL z I W -� U U z 11LCL z oQw J J � J U) � � z5 uj w w z cn Q `` zLU U C)Q LC)Lu Co z J c) J_ m W U 2 rn �- z m m Q W z U m O — Z W Y 0 co m N � I11 W U z zI1' YO W m Q °w z v � CARS O�r�FEs 3 •, tToT �+�Q Sheet G2. 1 5/28/18 3 i 0 3 V o 8 a E V X CONSTRUCTION NOTES & SEQUENCING THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT EROSION IS MINIMIZED AND THAT COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, AND ORDINANCES IS MAINTAINED THROUGHOUT EXECUTION OF THIS PROJECT. 1. CONTRACTOR TO SET UP AN ON-SITE PRE -CONSTRUCTION CONFERENCE WITH NCDEQ EROSION CONTROL INSPECTOR TO DISCUSS EROSION CONTROL MEASURES.PRIOR TO BEGINNING ANY WORK. 2. INSTALL SILT FENCE & ASSOCIATED MEASURES PER PLANS TO ESTABLISH PERIMETER PROTECTION. INSTALL DOUBLE ROW SILT FENCING ALONG THE TOE OF SEDIMENT BASIN 2 NEAR FLOOD PLAIN LIMITS. 3. AFTER PERIMETER PROTECTION MEASURES HAVE BEEN ESTABLISHED, BEGIN INSTALLATION OF THE SKIMMER BASINS AND ASSOCIATED GRADING MEASURES ONLY AS NECESSARY FOR INSTALLATION OF THESE DEVICES. EROSION CONTROL NOTES 1. BOTH BASINS SHALL BE INSPECTED DAILY (MONDAY THROUGH FRIDAY) FOR EXCESSIVE SILT. CONTRACTOR 4. UPON COMPLETION OF SKIMMER BASIN INSTALLATION MEASURES, IMMEDIATELY SEED OF REACHING FINAL GRADE. WESLEY OAKS HOA Stabilization Time Frame Stabilization Time Frame Exceptions Perimeter dikes, swales, ditches SHALL REMOVE EXCESSIVE SILT FROM THE TRAPS IMMEDIATELY BEFORE CONSTRUCTION COMMENCES ON EACH BK. 4384-523 and slopes - BASIN DRAINAGE AREA WORKING DAY.AS NECESSARY. MAINTENANCE SHALL CONTINUE THROUGH COMPLETION OF THE PROJECT. 7 days None PROPOSED HIGH HAZARD SILT FENCE O W If slopes are 10' or less in length TAX PIN: 06-048-323 7 days and are not steeper than 2:1, 14 TEMPORARY SLOPE DRAIN 2. THE CONTRACTOR ENGAGED IN OR CONDUCTING THE LAND -DISTURBING ACTIVITY SHALL BE RESPONSIBLE FOR NOW OR FORMERLY I 14 days / INSTALLING AND MAINTAINING ALL TEMPORARYAND PERMANENT EROSION AND SEDIMENT CONTROL MEASURES ZONE:R-40 ROY & MELISSA HALL All other areas with slopes flatter 14 days AND FACILITIES DURING THE DEVELOPMENT OF THIS SITE AS REQUIRED BY THE APPROVED PLAN. OPERATIONS USE: COMMON AREA BK. 4461-613 HQW Zones) * "Extensions of time may be approved by the permitting authority based on weather or other AND MAINTENANCE CONDITIONS ARE INCLUDED IN THE PLAN OUTLINING HOW THE CONTRACTOR SHALL PROVIDE I TAX PIN: 06-027-042 J W Y O = U) FOR OPERATIONS AND MAINTENANCE DURING CONSTRUCTION. m O NOW OR FORMERLY/ MARLENE LYONS Z 2 3. WITHIN SEVEN CALENDAR DAYS FOLLOWING SOIL DISTURBANCE OR RE -DISTURBANCE, ALL PERIMETER SEDIMENT ' ZONE:R-40 TRUSTEE CONTROLS SHALL BE INSTALLED AND TEMPORARY STABILIZATION MEASURES SHALL BE COMPLETED ON TOPSOILUSE: ` RESIDENTIAL BK. CS13-496 STOCKPILES. TAX PIN: 06-027-042A n / NOW OR FORMERLY / 4. AREAS AT FINAL GRADE SHALL RECEIVE PERMANENT STABILIZATION MEASURES WITHIN SEVEN CALENDAR DAYS ` ft� . ZONE: R-40 / USE: RESIDENTIAL AND STABILIZE ALL BOTH SEDIMENT BASINS (INCLUDING INTERIOR WALLS, WEIR C CREST, AND EXTERIOR WALLS) 5. THE RESPONSIBILITY FOR MAINTAINING ALL PERMANENT EROSION AND SEDIMENT CONTROL MEASURES AND ` , ` lA4C3 RICHARD KAPITAN FACILITIES AFTER SITE LAND DISTURBING ACTIVITY IS COMPLETED SHALL LIE WITH THE LANDOWNER OR PERSON _'� OO, Ro BK. 6012-624 NOTE: SLOPES STEEPER THAN 3:1 SHALL BE STABILIZED WITHIN 7 DAYS. , I/"- 5. UPON COMPLETION OF PHASE 1 EROSION CONTROL MEASURES, CONTRACTOR IS TO IN POSSESSION OR CONTROL, EXCEPT FACILITIES AND MEASURES INSTALLED WITHIN ROAD OR STREET /qD TAX PIN: 06 027 0048 - I I� ,)I ( /:-: CONTACT NCDEQ FOR AN INSPECTION. RIGHT-OF-WAYS OR EASEMENTS. \ w_ `w` `` ­- p/ ,84/ SLOPES 3:1 OR FLATTER STABILIZATION SHALL BE PROVIDED WITHIN 14 DAYS. U NOW OR FORMERLY 6. AFTER NCDEQ INSPECTION AND APPROVAL, START CLEARING AND GRADING OF THE 6. ADDITIONAL CONTROL DEVICES MAYBE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION � _W� ` _ ` R/W ZONE:R-40 RICHARD KAPITAN -SITE AS NEEDED FOR ROUGH GRADING OPERATIONS MAINTAIN EROSION CONTROL AND /OR OFF-SITE SEDIMENTATION. BENTON EDWARDS � -I`USE: USE: RESIDENTIAL BK. ACT 17 BENTON EDWARDS - ` -- BK. 601 -027 - DEVICES AS NECESSARY TO PREVENT OFF SITE SEDIMENTATION. - w` ` J 7. RUNOFF FROM BUILDING PADS AND OTHER RELATIVELY LEVEL AREAS MUST BE DIVERTED BY USE OFA TRACT 1 _ _ ' -_ I , TAX PIN: 06-027-0048 BK. 920-782 ` _ _ 7. ROUGH GRADE ENTIRE SITE WITH APPROVED STRUCTURAL FILL MATERIAL. TEMPORARY DIVERSION DITCH AT THE TOP OF A FILL SLOPE TOWARDS EITHER A SLOPE DRAIN OR RIP -RAP LINED PLAT CAB. D, FILE 583 `W- NOW OR FORMERLY CHANNEL DOWN THE FILL SLOPE. THE SLOPE DRAIN OR RIP -RAP LINED CHANNEL SHALL REMAIN IN PLACE UNTIL TAX PIN: 06-027-044 TAX PIN: 06-027-043 � -W-` _ ,'/ 7 NOW OR FORMERLY - x_ _ , / , ZONE:R-40 8. AS PORTIONS OF THE SITE ARE BROUGHT UP TO GRADE, THE CONTRACTOR SHALL THE FILL SLOPE HAS BEEN ADEQUATELY STABILIZED WITH ESTABLISHED VEGETATION. ) NOW OR FORMERLY ` �W� _ T - - ----� , r USE: RESIDENTIAL ADJUST EROSION CONTROL MEASURE AS NECESSARY. LANDON MUNDY ZONE:R-40 � ` - H - - - - c _ ' 8. SILT FENCE SHALL BE A MINIMUM OF 10 FT OFF THE PROPOSED TOE OF SLOPE TO PROVIDE SPACE FOR USE RESIDENTIAL - - ® _ - " . . ` l Jl l� ` - - 9. AS SITE IS BROUGHT TO FINAL GRADING, INSURE SOIL STABILIZATION MEASURES AND MAINTENANCE AND SEDIMENT -STORAGE TO THE MAXIMUM EXTENT POSSIBLE. BK. 6900-413 I �Y I - TEMPORARY GRAVEL SEEDING SCHEDULE ARE FOLLOWED AS PER THE PLANS. I TRACT 2 , I I -_ W _ CONSTRUCTION ENTRANCE _ : _ 9. GRADED SLOPES AND FILLS SHALL BE PROTECTED WITH A ROLLED EROSION CONTROL PRODUCT IF COMPLETED PLAT CAB. D, FILE 583 - - , - 1 - ' - ' _ - - - /b1i '596- - - - - - I `� _ _ NCDENR STD.: 6.06 - - I 10. CONTRACTOR TO COORDINATE INSPECTION AND APPROVAL BYA REPRESENTATIVE OF OUTSIDE OPTIMUM GERMINATION SEASONS, WHEN UNFAVORABLE WEATHER CONDITIONS PREVENT TAX PIN: 06-027-045 " THE LAND QUALITY SECTION PRIOR TO CONVERSION OF THE SKIMMER BASIN TO A ESTABLISHMENT OF VEGETATION GROUND COVER. NOW OR FORMERLY " ' - ' -- ' - - POST CONSTRUCTION STORMWATER MANAGEMENT BASIN AND BEFORE REMOVAL OF 1 _= - -- - -- _ - y - �-- ' , 11" OAK - _ ' II , _ s / ANY EROSION CONTROL DEVICES.. 10. THE PERSON RESPONSIBLE FOR LAND DISTURBING ACTIVITY IS TO MAKE SURE THE APPROVED EROSION ZONE:R 40 / _� �_ � 0, � r GROUND STABILIZATION Site Area Description Stabilization Time Frame Stabilization Time Frame Exceptions Perimeter dikes, swales, ditches 7 days None and slopes - BASIN DRAINAGE AREA High Quality Water (HQW) Zones 7 days None PROPOSED HIGH HAZARD SILT FENCE O W If slopes are 10' or less in length Slopes steeper than 3:1 7 days and are not steeper than 2:1, 14 TEMPORARY SLOPE DRAIN O days are allowed. Slopes 3:1 or flatter 14 days 7 -days for slopes greater than 50 � _+ O feet in length. All other areas with slopes flatter 14 days None (except for perimeters and than 4:1. HQW Zones) * "Extensions of time may be approved by the permitting authority based on weather or other ite-specific conditions that make compliance impracticable." (Section 11.8 (2)(b)). -,--\ \---a \ __ i- Is,-EI-� I� -, - --- /'-_.- -'-Z_-I \ 1 h __,m-II: I h hVI .. . I I I -I II I - - " SSMH RIM 547.15 \ PO -_ h RO __ �I _- I � _, =_ _---I, -- \ -I_. -� - , __�- �--_ _- I ­�, -I :�:- ----,�� ffi- -- - ', - I -,Im-� �-, 4J\ _I\:- m,, -,�i- f2,11I��I_-:(s,- GRASS SWALE DETAIL (1"=40' SCALE) '7'III, �,(. I I , t,. I .. ,II,' r CONTROL PLAN IS FOLLOWED. INSPECTION REPORTS ARE REQUIRED. USE RESIDENTIAL 0 - ` _ I DAR - c - , ' ` IO " r / d3_, �� - ' CONCRETE WASHOUT AREA ' -1 / 11. SILT FENCE STONE OUTLETS ARE NOT INTENDED TO FUNCTION AS A MEASURE IN LIEU OFA SEDIMENT TRAP OR U _ /- - /� , / , -- ( \" ' - - , \ , O BASIN, AND OFFER NO FILTRATION VALUE FOR RETENTION OF SEDIMENT. PRIMARY PURPOSE IS TO PREVENT SILT ` Q, 0 i AR \ - - I Ir FENCE LAY DOWN FOR SMALL RETENTION AREAS. STONE OUTLETS SHOULD BE PLACED 1.0 FT. ABOVE THE / /� / , ' , j, ,-,�_I I"" _,,I , ,_I I /_,�-II 0 I � ,1 ,I , , ' , ' - r , - I � �� �\ 1 % ; ' l / LOWEST ELEVATION OFA FENCED AREA AS TO PREVENT PONDING BEHIND SILT FENCES THAT EXCEED 1.0 FT. - �j _ -,- , , / ,'_gI(I,,, I ," I:9:-�,,-I I 1 , I. ,-� -:I II - II ', II_�"-A- _, I 1,P� ,- - -�I11- 1,I I,,JI1i i 1I, ,A , '-_- t -II' _ / I II,I, ��-�-n - / III II-,I,C1.' _ - __ � rn JUDITH B. ZIMMER 61 0 -_ �/' -. , ' ' I \ LIMITS OF DISTURBANCE f \ /r TAX PIN: 06-027-049A \ / , / - , / ' �. \ ; ' ; co , 4, I , , II, , " ,I �II ",:, -'I ,I::,I I ,I II ',, "I, : ,!: ,I I, , ,� ,, I, ,,, II, , " ,,I I , ,,,, ,\, I -, \I - 1 ',"I ,,II \I, - V1, - ,� ,- I �-:�-1I-__, -I, /--: I " , -, . -, , , _,1 ,,_- I -III- _ I I I ", ,,. N _ _I ,,- I, I 1,,, ,(,,/, - , , -- -- , ---' -,-,I I II -I --1II---51-,--' , ------ , ,\-,---- ,- 1 - --I^ ,, -- ' ,- ---- - "-- 1 I--.--- -- , ,--.-., ,, I-1-1 I --:-- , ,- -- I I, - .- ',-:- .--I , I- � - - -,, - . , ---I*_,, /, II, �, ,-_ , - - -, I, -, - - _1 _ I-1- ) -I- I, 1,�--/5 _, , -- , -_-�-,.-- /- --1- --:, `,� '/ , \I --ff " I ,I- ,- -, \, - -, " - ,- -,, I- -;, , -,, II- - ,, _I I_\�,. " I �- I,- _ , ,--/,�I I- -I_r- ,I -1- --,-1,,'-- -- -I , , -, -- .+�- -,I -,,"I-,I ,'- '-1- r_J-_* -Q _,.,, -- , 1- -,-', -,k-I -I,, -_- ' -I----I ,_ -, L- , _,,- / -\ _,I I /- , I1" -I_ I,; , _, ,I -I'"/, I 61_III "1I ,6I,-1 , I- II0 I' I ,I ,II' I ,/II- - ,\- ,# ,,I,,-- I I. II I " ,--- I' /, ,I " 1 -," - I - I II , '�--I BK. 1747-130 / / i / , R _ �, ' � \ PART OF TRACT 6 ' . ' ' - _ - , , 1 PLAT CAB. K, FILE 722 - - - ' /% / / - " i /- .I i I / I ' ' -,lI r �, , . Iou - NQWQR FORMERLY TOTAL DISTURBED AREA = 9.98 AC l' u , + ; ' I ZONE: R-40 - , 1 _ _ '�' , , **' ) ' /' - - w°6 USE RESIDENTIAL Y / % f \ _ / / :1I" 1 % N°" / i / a / 1 „ CE�' - ` - � , I SAO / / a / // , / , ' / ` ' h'�10' CED7tI - - - - _ _1 A ' , , - ,I I'\ 6" cEbA ' , CEDAR - PROPOSED 20' WIDE RIP -RAP SPILLWAY - / ` ° ,0r6 / ' / / 13"CEDAJ I \I _ - - _ 'SPILLWAY EL - 578.00 /, d JOHN H. HUCKERT, JR. , '/ / .� " , 6" CEDAR 'I \ - _ % �-, �- %- " /,., E" Ir -r �'. , _ BK. 6354, PG. 141 jo_ EDAR _ _ ; ; - PROPOSED BAFFLE (TYP) �\ TAX PIN: 06-027-006"Z // " I / �` , - ,. ^� 1 _ NOW OR FORMERLY CHARLES B. BAUCOM , ' _ JJ ' , , PROPOSED 24" TEMPORARY SLOPE DRAIN - - , , - - _ _ - _ , TAX PIN: 06-027-048 j / / . , /,r 11;EL -, - ' -- - ' - - - , - //<QiTR E �� \^`` P', ZONEDEN TRACT 5 - �I I LIMITS OF DISTURBANCE A _ 1 1; '/ / , USE RESIDENTIAL / ` PLAT CAB. K, FILE 722 /, o" / l 1 ' '��?�j1� - / CE ` 580\` l // NOW OR FORMERLY , / - co /' '_� � 4 _ ZONE: R 40 -I J 1,845, 045 s�j. ft. ' " /' ' J so 1010EDAR_ 1 X , I USE RESIDENTIAL / +Q ,'42,35 aCC@S' ' ' ♦ - " ' / f \\, , / # / , - 16",CEDAR - O 1 k iZ L , , J o' m, ,' ,,y/ ,/ - - - iN) i 2 / � iQ , / , - ,� , x'14, CE �, ' / l ,�i ,/ /I , J 19" CEDAR � I , / , BLAIR BURKE / // 0\- PROPOSED SILT FENCE (TYP) . AR ; , ` _ ,, , � �:II,,,, I� ,I -I ,:-,,I,I I -,, ,II , I,- ,, ,II , -, ,�I-I CI I I /O - ,/ ,,, ,, BK. 7100-160 ` ' -( `- - \ i, , , ,'i1',CEDAR TAX PIN: 06-030-014A - ` . / � `- / - - - - - "% * -,/ " ' ' ' "-c61� , ,461"PINE/' I ; - / I I- .XI -.:-,I,I �-'1-I_ ',- � / /TRACT 2 Q -I-! - ", , , '% I tt / , PLAT CAB. N, FILE 524 !' , \ \N- - - - - - _ '- , � 111WILD / , ` / JUNE MOORE / - j 0, Q��_ERSMAM6N 10" LM 233' I NOW OR FORMERLY r , � y DOROTHY MOREE / BK. 6403, PG. 115 ZONE: R-40 \ ---_ - -I a� - , ; �, , � ; �" - ; ,, , io",cPAD ' _ - - - - - _ \, 1/ ' ( _596- � . - USE: VACANT \ � ` / j /' ; , `16ME1 M I / PLAT D-520 �. � - - - _ --590 _l _ - - jl' , _ / /I f 5g� TAX PIN: 06-027-010 �, O - _ •� _ _ \; -, _ _ =, i \\' / 10"CEDAR' IV PROPOSED 36" DIAMETER CMP RISER NOW OR FORMERLY ` ° !. o I / / WITH TRASH RACK ON BALLAST PAD, ( ; . ZONE:R-40 / I , \ ` = ; ; _ _ _ _ _ _ \ t j / ; I y i WITH PROPOSED FAiRCLOTH SKIMMER\; USE RESIDENTIAL t I , ' - � I' - - - - - - - -- _ _ _ _ - \ N - F- - ' _- , 17"CED ' - ,' /' r /( / _ _ PROPOSED 24" CMP BARRELL @2.8% SKIMMER BASIN 13,1 - - _ / I JACK CASE / , � , 1 ' `r /�N 'I , , ` \ - \ / , ' - �j � I � , , ,' , " / , 51�, /� , ; , ; i�� - DRAINAGE AREA EVATI0) == 679. 0 /- ; , BK. 7071-403 / Al ; ` ,�� ` i \ _ / ) , 1 , o % TOP OF BERM ELEVATION 679.00 1J EDAR TAX PIN: I1 06-030-0148 ' ,C \ �' LIMITS OF DISTURBANCES 1s" CED 4oit�DAR�� ( PROPOSED RIP -RAP SPILLWAY ELEVATION = 678.00 TRACT 3 \ ` ; - - / , t4"CEDAR; , {\ , , ,i,'' / , o , /, _ ' RISER WEIR ELEVATION = 677.00 _ \ PLAT CAB. N, FILE 524 �' s' / ` jam/ , f / - / \ ` ' , I `' CLEANOUT ELVATION = 576.50 1 , NOW OR FORMERLY \ , o \` ' �` , 12" WILd C%�ERRY \ "I, 15 13" CEDAR 1 ILD CHERRY r��_y //- BOTTOM OF BASIN ELEVATION = 575.00 1� ZONE:R-40 ' PROPOSED SILT FENCE ` d ✓, , j _ _ 3 ,17"CEDAR {`l �' k �� REQUIRED VOLUME (cf) = 28,044 / USE: VACANT \' 1,� . I, OUTLET - � ," , " 12" CEQAR_ n,� ; y t ` ` ' i �_ PROVIDED VOLUME (cf) = 29,583 ) ; ; , , \ J V % , = 4 ' _Z ; - I 13"CEDAR � ' - - - - ' � � , \ ,\ ` , \ ' ` I SPILLWAY LENGTH (ft) = 20.00 /; LOVELL FAMILY 1 , , _ � - - ` _ J _ / , , O -� RISER - 36" CMP LIMITED PARTNERSHIP `,' ,% I , , ',i ♦ - _ _ _ I , "%, , /- \ 24:0 II II�, - � -II- - -_ \ ,I - I:- -I- � - ' - \ , \\- \ C - ' _ / r o , , \ , \ 0 , ` \- i_ _ _ BARREL = 35 LF 24" CMP @ 2.86% BK. 1488, PG. 821 „ , _ _ ``� f; �" ' = o"CEDAR _ 1`3"ct� IO 1 o SKIMMER SIZE = 4" TAX PIN: 06-027-007 r Q ' , ` \ - - - - , ,/ 12"PI _ \ , \ , , C a ,0 - - - - _ - -, ORIFICE SIZE = 3.4" NOW OR FORMERLY 1`' \ , ; \\ �" - _ _ _ g m o \ \ , " UNINCORPORATED ,\ _ 0 _ _ _ - - - 1 EDAR am I DAVID E. BALLENGER ti \ , ,,\ ' , - TI' _1 - - _ . - , _ _ 10 c R %-/ t o _ _ It , , ' UNION COUNTY BK. 602-107 ( I`` \` \_ ` t -, O1, L 13"PINEE 14"PINE \ _ - O SB�� _/' / ',,,1 I ' ' TAX PIN: 06-030-002A ` 4 ` \` , `\ _ _ _ I - /'-_ \ NOW OR FORMERLY I \ S ` 1� , ` ,\', ,\, I 0 12' CEDAR I� 13° PINEO , \ ` -, - _ - - _ ZONE: R 40 V - / 1 , \, _ - - J UNDISTURBED Q o - 10" PINE .� \ - - - _ - 0 _ _ _ - _=' _ . - USE: VACANT l i �, V \ _ - - �' _ - NATURAL ,-I _ - - / 12" PINE \ -- - - - MICHAEL DAVIS TAX PIN: 06-030-002B NOW OR FORMERLY ZONE: R-40 USE: VACANT LEGEND -ELEV- EXISTING CONTOUR ELEV PROPOSED CONTOUR _-��--__:- bNO ` 1 i ,, I 1-. , "I ,I _ Z -,II 1, -,I :- I I ,II �I, I. ,I:, 1 , . \ =_ AREAE �I ,Q ` - = / I Are '12FDAR R 4„ E `'�,` 1 ` �6r -�Z�CFDAR 11 _ o _ _' _ - 670- � / `r6 ,\ ` \ - , 1 " , , 13" PI \ MARK J. ROSENBL UM , - - - ; : - - - ' " \ / _ PROPOSED BAFFLE (TYP) _ _ _ - �" - " - • 1/ EDAR1T� LIMITS OF DISTURBANCE \ tK' I , &KATE K. ROSENBLUM - " _ _ _ _ _ _ _ _ - _ / F I I� - 6, BK. 550, PG. 851 PROPOSED DOUBLE ROW SILT FENCE 1 _ - __ - _ - - - \ ' \ 15"CEbAR \ - _ - b TAX PIN: 06-027-005A _ _ _ _ _ _ _ \ - / I, • • s - \- - - / 14" CEDAR / l , " / II NOW OR FORMERLY i _ _ _ - - _ -- -- _- "_ , , ZONE:R-40 0 PROPOSED 30' WIDE RIP -RAP SPILLWAY I ss cao �! ��``r119" WILD CHERRY _ 56 / SPILL AY EL = 550.00 I f kx \ ' r ,\� o o ,I' I USE RESIDENTIAL - j -_ -_ - _ - - ----- - - 1 / 0 N-6 ��`\' 11�- 36" OAK ' I \ S -'- 4- - , _ / /c/ r _ _ - � _ _ - _ _ _ ` /JJ//\` 6O y I "CEDAR _ _ - / 10" PINE /�,\/ ' 10" €DAR - - - i \ / 1 \t Q *- -_ O���°!�.-, . _.I ,.,_.I.- "--,, r_ -.IC�I,I`-,-,E-_,I D- /I I-- _ 1 , 11,-, .-7 -._ 1 1- A-I.I ,:-_, - , :--_-- _- _� f 0" CEDAR ! 14 = -- _ / _Q�iS,\ 0�" Y ` -572 13OAK �,%' _ _ - - - - �, :/ 3 , 17" SYC RE f f O I � ' jig 12" OAK - i r ; / I \ �_ cS \' \ ,# /, i. 1 ' . AR -- I - - __ l 'T/�. i , , \ O // i ` r F2 CEDAR -` - \ I -- '� i la" EDAR ; \ _ = j /' , _ 11 -CEDAR - /, ; , 1 • r / , - Fi °O I IC 1 _ f8"CEDAR" r' � 11"CEgAR � , 1)' PEDAR 70 , - - - - - "/ PROPOSED 4 z4' (INSIDE) CONCRETE RISER 5 - WITH TRASH RACK ON BALLAST PAD, WITH �I - _ i� I \ 10"CEDAR _ j, - ^/ // / II 10" C 10" C AR_�� J _ I\ PROPOSED FAIRCLOTH SKIMMER 4- , , \ I, , _ CEDAR- ` - , _ - _ _ _ _ _ , ' 0" ', AdINAPL ` ` , (USE PERMANENT STRUCTURE &ATTACH /� AR oma, \ _ \4"GUM SKIMMER TEMPORARILY- SEE DETAIL ON C 3.7) -�- d\ , _ _ = _I =�- _ , = - ^EDAR_ X" '' / ,.r, �i n �k � � - - - _�_ _ - ' + dE-0 1Q "CEDAR , o - _ _ : 0 0 11 " CE6AR CEDAR , j • /. J PROPOSED 24"RCP BARREL @ 0.50% h1 11"CEDAR �' - _ / - - _ _ 1 -EDAR _ - , , _N, \ � • \ �V� PROPOSED R 0 , _ _ `; - ,\- ,%- - _ - ` _ _ _ . �"- / % ; PROPOSED RIP -RAP DOUBLE ROW 2 - _ c A 1 r cEBAR - _ - - _ _ - ' , - - - - - - - % E cS` \ \ _ 11 a O _ - - - - - - - - - _ _\� - _ - _ _ _ / , / _ 1r9" OAK , \ SILT FENCE 1 o " 1�'CEDAR - \� # / _ ;,, o"PINE �+ 1 I� 10 o^c�Al�-i1-�. ,/, �' C�� _' / i "OAK ' , 1 ` - - P, EX 18"S. S. -546, - �I 0 13"CEDAR, - - - - - - - - j'-% \- - _ _ - - - / / \ - - � ' - "/ \- �\ . _ h �v_i Ib �I _ 0 13"CEDAR - - - - - / - -j, _ � -- `--- -- - - __ , 1 -,� _ - - - - - _ \ / - '��-a �� m it _ aa^ cvr4MORE -� S ` ` - - - _ - - - - "_ - - - _ _ - ,� I o _ _EX.18"S _ / _" - - � 80- o_ - , =8 - - -,L- ,„ __ - 40 LM - - - - -x-_ _ -•I -_ __ "_I _- '� i - _ _ _ EX.18", - a'O`ncL ---____ = I �l ' _ -'F .FLM PROPOSED SILT FENCE _ X _ _ , � - �- cq __ _ - ` I ss �= OUTLET _ _ - - . _ - - _ _ - - !i _ _ _ --1_ S _ _SKIMMER BASIN 2 : _� _ \_,, - �' ',�) J " - DRAINAGEAREA (C=0.50) = 18.01 AC \ - - EAST FORK OF _ - _ = = �- _ - - TOP OF BERM ELEVATION = 551.00 SPILLWAY ELEVATION = 550.00_ RISER WEIR ELEVATION = 549.00 CLEANOUT ELVATION = 542.50\ BOTTOM OF BASIN ELEVATION = 541.00 REQUIRED VOLUME (cf) = 28,044- PROVIDED VOLUME (cf) = 118,449 SPILLWAY LENGTH (ft) = 30.00\ RISER = 4'x4' (INSIDE) CONCRETE RISER \ BARREL = 287.10 LF 36" RCP @ 0.70% SKIMMER SIZE = 6" \ ORIFICE SIZE = 6" . TWELVE MILE CREEK - `__ _ _ - - - - _ - - = - � : - - - - , J - - �, - _ --- --- -1 - - - LOVELL FAMILY '1 - LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED GRAPHIC SCALE UNION COUNTY \ ZONE: R-40 0 100' 200' _SE: VACAN�\ ( IN FEET ) 1 inch = loo ft. SKIMMER BASIN EN GAIN EERING Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 4* 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4 Inches Weir Coefficient 3 Orifice Radius 1.71nches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches SKIMMER BASIN EN GAINEERLING y1 r►- Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 111111111 110 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4Inches Weir Coefficient 3 Orifice Radius 1.7 Inches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches M 0 0 LO cn o � Lo o 0 �) o0co coM Z W a � � o Q � U Q c W � W '_ 0 W z Z co �co �� J Q N N � N Z m '� 00 WW QM `- t'') -a o N 7 Z) TD TEMPORARY DIVERSION DITCH ■ � LIMITS OF DISTURBANCE - BASIN DRAINAGE AREA ---�---�--- PROPOSED SILT FENCE -o-o-o-o-o= PROPOSED HIGH HAZARD SILT FENCE O W PROPOSED INLET PROTECTION aPROPOSED TEMP. CHECK DAM Y TEMPORARY SLOPE DRAIN ` 1 i ,, I 1-. , "I ,I _ Z -,II 1, -,I :- I I ,II �I, I. ,I:, 1 , . \ =_ AREAE �I ,Q ` - = / I Are '12FDAR R 4„ E `'�,` 1 ` �6r -�Z�CFDAR 11 _ o _ _' _ - 670- � / `r6 ,\ ` \ - , 1 " , , 13" PI \ MARK J. ROSENBL UM , - - - ; : - - - ' " \ / _ PROPOSED BAFFLE (TYP) _ _ _ - �" - " - • 1/ EDAR1T� LIMITS OF DISTURBANCE \ tK' I , &KATE K. ROSENBLUM - " _ _ _ _ _ _ _ _ - _ / F I I� - 6, BK. 550, PG. 851 PROPOSED DOUBLE ROW SILT FENCE 1 _ - __ - _ - - - \ ' \ 15"CEbAR \ - _ - b TAX PIN: 06-027-005A _ _ _ _ _ _ _ \ - / I, • • s - \- - - / 14" CEDAR / l , " / II NOW OR FORMERLY i _ _ _ - - _ -- -- _- "_ , , ZONE:R-40 0 PROPOSED 30' WIDE RIP -RAP SPILLWAY I ss cao �! ��``r119" WILD CHERRY _ 56 / SPILL AY EL = 550.00 I f kx \ ' r ,\� o o ,I' I USE RESIDENTIAL - j -_ -_ - _ - - ----- - - 1 / 0 N-6 ��`\' 11�- 36" OAK ' I \ S -'- 4- - , _ / /c/ r _ _ - � _ _ - _ _ _ ` /JJ//\` 6O y I "CEDAR _ _ - / 10" PINE /�,\/ ' 10" €DAR - - - i \ / 1 \t Q *- -_ O���°!�.-, . _.I ,.,_.I.- "--,, r_ -.IC�I,I`-,-,E-_,I D- /I I-- _ 1 , 11,-, .-7 -._ 1 1- A-I.I ,:-_, - , :--_-- _- _� f 0" CEDAR ! 14 = -- _ / _Q�iS,\ 0�" Y ` -572 13OAK �,%' _ _ - - - - �, :/ 3 , 17" SYC RE f f O I � ' jig 12" OAK - i r ; / I \ �_ cS \' \ ,# /, i. 1 ' . AR -- I - - __ l 'T/�. i , , \ O // i ` r F2 CEDAR -` - \ I -- '� i la" EDAR ; \ _ = j /' , _ 11 -CEDAR - /, ; , 1 • r / , - Fi °O I IC 1 _ f8"CEDAR" r' � 11"CEgAR � , 1)' PEDAR 70 , - - - - - "/ PROPOSED 4 z4' (INSIDE) CONCRETE RISER 5 - WITH TRASH RACK ON BALLAST PAD, WITH �I - _ i� I \ 10"CEDAR _ j, - ^/ // / II 10" C 10" C AR_�� J _ I\ PROPOSED FAIRCLOTH SKIMMER 4- , , \ I, , _ CEDAR- ` - , _ - _ _ _ _ _ , ' 0" ', AdINAPL ` ` , (USE PERMANENT STRUCTURE &ATTACH /� AR oma, \ _ \4"GUM SKIMMER TEMPORARILY- SEE DETAIL ON C 3.7) -�- d\ , _ _ = _I =�- _ , = - ^EDAR_ X" '' / ,.r, �i n �k � � - - - _�_ _ - ' + dE-0 1Q "CEDAR , o - _ _ : 0 0 11 " CE6AR CEDAR , j • /. J PROPOSED 24"RCP BARREL @ 0.50% h1 11"CEDAR �' - _ / - - _ _ 1 -EDAR _ - , , _N, \ � • \ �V� PROPOSED R 0 , _ _ `; - ,\- ,%- - _ - ` _ _ _ . �"- / % ; PROPOSED RIP -RAP DOUBLE ROW 2 - _ c A 1 r cEBAR - _ - - _ _ - ' , - - - - - - - % E cS` \ \ _ 11 a O _ - - - - - - - - - _ _\� - _ - _ _ _ / , / _ 1r9" OAK , \ SILT FENCE 1 o " 1�'CEDAR - \� # / _ ;,, o"PINE �+ 1 I� 10 o^c�Al�-i1-�. ,/, �' C�� _' / i "OAK ' , 1 ` - - P, EX 18"S. S. -546, - �I 0 13"CEDAR, - - - - - - - - j'-% \- - _ _ - - - / / \ - - � ' - "/ \- �\ . _ h �v_i Ib �I _ 0 13"CEDAR - - - - - / - -j, _ � -- `--- -- - - __ , 1 -,� _ - - - - - _ \ / - '��-a �� m it _ aa^ cvr4MORE -� S ` ` - - - _ - - - - "_ - - - _ _ - ,� I o _ _EX.18"S _ / _" - - � 80- o_ - , =8 - - -,L- ,„ __ - 40 LM - - - - -x-_ _ -•I -_ __ "_I _- '� i - _ _ _ EX.18", - a'O`ncL ---____ = I �l ' _ -'F .FLM PROPOSED SILT FENCE _ X _ _ , � - �- cq __ _ - ` I ss �= OUTLET _ _ - - . _ - - _ _ - - !i _ _ _ --1_ S _ _SKIMMER BASIN 2 : _� _ \_,, - �' ',�) J " - DRAINAGEAREA (C=0.50) = 18.01 AC \ - - EAST FORK OF _ - _ = = �- _ - - TOP OF BERM ELEVATION = 551.00 SPILLWAY ELEVATION = 550.00_ RISER WEIR ELEVATION = 549.00 CLEANOUT ELVATION = 542.50\ BOTTOM OF BASIN ELEVATION = 541.00 REQUIRED VOLUME (cf) = 28,044- PROVIDED VOLUME (cf) = 118,449 SPILLWAY LENGTH (ft) = 30.00\ RISER = 4'x4' (INSIDE) CONCRETE RISER \ BARREL = 287.10 LF 36" RCP @ 0.70% SKIMMER SIZE = 6" \ ORIFICE SIZE = 6" . TWELVE MILE CREEK - `__ _ _ - - - - _ - - = - � : - - - - , J - - �, - _ --- --- -1 - - - LOVELL FAMILY '1 - LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED GRAPHIC SCALE UNION COUNTY \ ZONE: R-40 0 100' 200' _SE: VACAN�\ ( IN FEET ) 1 inch = loo ft. SKIMMER BASIN EN GAIN EERING Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 4* 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4 Inches Weir Coefficient 3 Orifice Radius 1.71nches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches SKIMMER BASIN EN GAINEERLING y1 r►- Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 111111111 110 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4Inches Weir Coefficient 3 Orifice Radius 1.7 Inches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches M 0 0 LO cn o � Lo o 0 �) o0co coM Z W a � � o Q � U Q c W � W '_ 0 W z Z co �co �� J Q N N � N Z m '� 00 WW QM `- t'') -a o N 7 Z) m Og 10 m 73 SQ IM Z m O Z O W W U (/) Y N O Z = O � . TWELVE MILE CREEK - `__ _ _ - - - - _ - - = - � : - - - - , J - - �, - _ --- --- -1 - - - LOVELL FAMILY '1 - LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED GRAPHIC SCALE UNION COUNTY \ ZONE: R-40 0 100' 200' _SE: VACAN�\ ( IN FEET ) 1 inch = loo ft. SKIMMER BASIN EN GAIN EERING Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 4* 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4 Inches Weir Coefficient 3 Orifice Radius 1.71nches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches SKIMMER BASIN EN GAINEERLING y1 r►- Project CAVESSON Client BOWMAN Project # 6198 Date 5/28/2018 2013A Van Buren Ave. Designation SKIMMER BASIN 1 Designer KEW Indian Trail, NC 28079 NC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 12.32 Acres 536,659 Square Feet Total Disturbed Area 3.19 Acres 138,956 Square Feet C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 575 5,190 0 0 110 7.03 Inches per Hour 576 11,309 8,250 8,250 Q10 43.30 CFS 577 18,065 14,687 22,937 111111111 110 578 25,456 21,761 44,697 Required Volume 11,484 Cubic Feet 579 31,285 9,156 53,853 Required Surface Area 18,838 Square Feet Provided Volume 44,697 Cubic Feet OK Provided Surface Area 25,456 Square Feet OK Length 245 Feet Minimum Spillway Design Width 120 Feet Q10 43.30 CFS L/W Ratio 2.04 OK H 1 Feet C 3 Spillway Elevation 578 Surface Area at Spillway 25,456 L 14.43 Feet Spillway Design Spillway Length 20 Feet Days to Drain 3 Days Head over Spillway 1 Feet Skimmer Size 4Inches Weir Coefficient 3 Orifice Radius 1.7 Inches Max Flow 60 CFS OK Orifice Diamter 3.4 Inches M 0 0 LO cn o � Lo o 0 �) o0co coM Z W a � � o Q � U Q c W � W '_ 0 W z Z co �co �� J Q N N � N Z m '� 00 WW QM `- t'') -a o N 7 Z) m Og 10 m 73 SQ IM Z m O Z O W W U (/) Y N O Z = O � >_ 00 � � _+ O O W O ZUJ z J W Y O = U) m O Q Z 2 U) M 0 0 LO cn o � Lo o 0 �) o0co coM Z W a � � o Q � U Q c W � W '_ 0 W z Z co �co �� J Q N N � N Z m '� 00 WW QM `- t'') -a o N W Q_ Q W J U U Z CL z z W oQw J J J v `� � z 5 UJ w wzU) � o -Q� Q ``z U W Q�z W W00 Z) Q �It-_ O J _ CO 7 Z) m Og 10 m 73 SQ IM Z m O Z O W W U (/) Y N O Z = O � W Q_ Q W J U U Z CL z z W oQw J J J v `� � z 5 UJ w wzU) � o -Q� Q ``z U W Q�z W W00 Z) Q �It-_ O J _ CO Sheet C-3.0 7 00 � m Og 10 m 73 O 0C U W U Z m O Z O W W U (/) Y N Z co = O � >_ 00 � � _+ O O W O ZUJ z J W Y O = U) m O Q Z 2 U) Sheet C-3.0 3 i E m I oz 8 a E V X CONSTRUCTION NOTES & SEQUENCING THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT EROSION IS MINIMIZED AND THAT COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, AND ORDINANCES IS MAINTAINED THROUGHOUT EXECUTION OF THIS PROJECT. 1. CONTRACTOR TO SET UP AN ON-SITE PRE -CONSTRUCTION CONFERENCE WITH NCDEQ EROSION CONTROL INSPECTOR TO DISCUSS EROSION CONTROL MEASURES.PRIOR TO BEGINNING ANY WORK. 2. INSTALL SILT FENCE & ASSOCIATED MEASURES PER PLANS TO ESTABLISH PERIMETER PROTECTION. INSTALL DOUBLE ROW SILT FENCING ALONG THE TOE OF SEDIMENT BASIN 2 NEAR FLOOD PLAIN LIMITS. 3. AFTER PERIMETER PROTECTION MEASURES HAVE BEEN ESTABLISHED, BEGIN INSTALLATION OF THE SKIMMER BASINS AND ASSOCIATED GRADING MEASURES ONLY AS NECESSARY FOR INSTALLATION OF THESE DEVICES. 4...N MPLETI N F KIMMER BA IN IN TALLATI N MEA RE 1 -1 -1 - - EROSION EROSION CONTROL NOTES 1. THE SEDIMENT BASIN SHALL BE INSPECTED DAILY (MONDAY THROUGH FRIDAY) FOR EXCESSIVE SILT. WESLEY OAKS HOA CONTRACTOR SHALL REMOVE EXCESSIVE SILT FROM THE BASIN BEFORE CONSTRUCTION COMMENCES ON EACH BK. 4384-523 WORKING DAY.AS NECESSARY. MAINTENANCE SHALL CONTINUE THROUGH COMPLETION OF THE PROJECT. TAX PIN: 06-048-323 2. THE CONTRACTOR ENGAGED IN OR CONDUCTING THE LAND -DISTURBING ACTIVITY SHALL BE RESPONSIBLE FOR NOW OR FORMERLY 1 / INSTALLING AND MAINTAINING ALL TEMPORARYAND PERMANENT EROSION AND SEDIMENT CONTROL MEASURES ZONE:R-40 ROY & MELISSA HALL AND FACILITIES DURING THE DEVELOPMENT OF THIS SITE AS REQUIRED BY THE APPROVED PLAN. OPERATIONS USE: COMMON AREA BK. 4461-613 AND MAINTENANCE CONDITIONS ARE INCLUDED IN THE PLAN OUTLINING HOW THE CONTRACTOR SHALL PROVIDE TAX PIN: 06-027-042 / FOR OPERATIONS AND MAINTENANCE DURING CONSTRUCTION. NOW OR FORMERLY / MARLENE LYONS � ZONE: R-40 TRUSTEE 3. WITHIN SEVEN CALENDAR DAYS FOLLOWING SOIL DISTURBANCE OR RE -DISTURBANCE, ALL PERIMETER SEDIMENT CONTROLS SHALL BE INSTALLED AND TEMPORARY STABILIZATION MEASURES SHALL BE COMPLETED ON TOPSOIL USE: RESIDENTIAL BK. CS13-496 STOCKPILES. ` TAX PIN: 06-027-042A NOW OR FORMERLY /�, 4. AREAS AT FINAL GRADE SHALL RECEIVE PERMANENT STABILIZATION MEASURES WITHIN SEVEN CALENDAR DAYS ` ZONE: R-40 CO O O S S S O SU S, S OF REACHING FINAL GRADE. / / eLwo / / AND STABILIZE ALL BOTH SEDIMENT BASINS (INCLUDING INTERIOR WALLS, WEIR USE: RESIDENTIAL C/�lq /I ,�Q� � RICBK. 6012A 21�AN CREST, AND EXTERIOR WALLS) 5. THE RESPONSIBILITY FOR MAINTAINING ALL PERMANENT EROSION AND SEDIMENT CONTROL MEASURES AND , H'I'V/C3 FACILITIES AFTER SITE LAND DISTURBING ACTIVITY IS COMPLETED SHALL LIE WITH THE LANDOWNER OR PERSON - ` OO, /� TAX PIN: 06-027-004B 5. UPON COMPLETION OF PHASE 1 EROSION CONTROL MEASURES, CONTRACTOR IS TO IN POSSESSION OR CONTROL, EXCEPT FACILITIES AND MEASURES INSTALLED WITHIN ROAD OR STREET - //_ ` ` 1 OqD _ RICHARD KAPITAN NOW OR FORMERLY CONTACT NCDEQ FOR AN INSPECTION. RIGHT-OF-WAYS OR EASEMENTS. -W` p/ '6 BK. 6012-624 ZONE:R-40 '64 /C TAX PIN: 06-027-0048 6. AFTER NCDEQ INSPECTION AND APPROVAL, START CLEARING AND GRADING OF THE 6. ADDITIONAL CONTROL DEVICES MAYBE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION � �W� R� USE: RESIDENTIAL SITE AS NEEDED FOR ROUGH GRADING OPERATIONS MAINTAIN EROSION CONTROL AND /OR OFF-SITE SEDIMENTATION. �'_� ` � • 1� NOW OR FORMERLY II BENTON EDWARDS W� _ ` / - ZONE:R-40 DEVICES AS NECESSARY TO PREVENT OFF SITE SEDIMENTATION. ` � _� _ 7. RUNOFF FROM BUILDING PADS AND OTHER RELATIVELY LEVEL AREAS MUST BE DIVERTED BY USE OFA BK. 734-397 � � W� _ __ � - _ - USE: RESIDENTIAL 7. ROUGH GRADE ENTIRE SITE WITH APPROVED STRUCTURAL FILL MATERIAL. TEMPORARY DIVERSION DITCH AT THE TOP OFA FILL SLOPE TOWARDS EITHER A SLOPE DRAIN OR RIP -RAP LINED TRACT 1 W _ _ _; / - I I / CHANNEL DOWN THE FILL SLOPE. THE SLOPE DRAIN OR RIP -RAP LINED CHANNEL SHALL REMAIN IN PLACE UNTIL PLAT CAB. D, FILE 583 BENTON EDWARD` _ bV_ ` 1� - - - , , / , 8. AS PORTIONS OF THE SITE ARE BROUGHT UP TO GRADE, THE CONTRACTOR SHALL THE FILL SLOPE HAS BEEN ADEQUATELY STABILIZED WITH ESTABLISHED VEGETATION. TAX PIN: 06-027-044 BK. 920-782 ` - I,y, _ ! - �- � _ _ � , I r/ ADJUST EROSION CONTROL MEASURE AS NECESSARY. ,-Q NOW OR FORMERLY TAX PIN: 06-027-043 - _ �/ • / , 1 ; : ,/ I 8. SILT FENCE SHALL BEA MINIMUM OF 10 FT OFF THE PROPOSED TOE OF SLOPE TO PROVIDE SPACE FOR LANDON MUNDY V/_ - _ - ° _ ZONE:R-40 - NOW OR FORMERLY 9. AS SITE IS BROUGHT TO FINAL GRADING, INSURE SOIL STABILIZATION MEASURES AND MAINTENANCE AND SEDIMENT -STORAGE TO THE MAXIMUM EXTENT POSSIBLE. BK. 6900-413 7 t ��` yY- ®- TEMPORARY GRAVEL SEEDING SCHEDULE ARE FOLLOWED AS PER THE PLANS. TRACT 2 USE RESIDENTIAL r , ' , , ' / / W- _ _ CONSTRUCTION ENTRANCE �_ _-_ 9. GRADED SLOPES AND FILLS SHALL BE PROTECTED WITH A ROLLED EROSION CONTROL PRODUCT IF COMPLETED PLAT CAB. D, FILE 583 ��' - - ' - ' _ - 601 I NO 596 _ - - - '� _ W - - =1V- NCDENR STD.: 6.06 10. CONTRACTOR TO COORDINATE INSPECTION AND APPROVAL BYA REPRESENTATIVE OF OUTSIDE OPTIMUM GERMINATION SEASONS, WHEN UNFAVORABLE WEATHER CONDITIONS PREVENT TAX PIN: 06-027-045 • , ' _ - - - - _ _ THE LAND QUALITY SECTION PRIOR TO CONVERSION OF THE SKIMMER BASIN TO A ESTABLISHMENT OF VEGETATION GROUND COVER. NOW OR FORMERLY k` - - - CONCRETE WASHOUT AREA POST CONSTRUCTION STORMWATER MANAGEMENT BASIN AND BEFORE REMOVAL OF _ - - e - - - - - - - - -, ANY EROSION CONTROL DEVICES.. 10. THE PERSON RESPONSIBLE FOR LAND DISTURBING ACTIVITY IS TO MAKE SURE THE APPROVED EROSION ZONE:R 40 I ' _ i1. CONTROL PLAN IS FOLLOWED. INSPECTION REPORTS ARE REQUIRED. USE RESIDENTIAL l \ I I �� y '� �' ry , ' � t O�1 _ (0 , 11. SILT FENCE STONE OUTLETS ARE NOT INTENDED TO FUNCTION AS A MEASURE IN LIEU OFA SEDIMENT TRAP OR U ` . ' 0 , ' � � r_7 OPEN 1 : 120 , , , \ OV / _ - LOT:,5 5 , � ' , - - -\ _ LOT . 1 BASIN, AND OFFER NO FILTRATION VALUE FOR RETENTION OF SEDIMENT. PRIMARY PURPOSE IS TO PREVENT SILT / 0 f / 9,596 Sq FENCE LAY DOWN FOR SMALL RETENTION AREAS. STONE OUTLETS SHOULD BE PLACED 1.0 FT. ABOVE THE 59;98,4 sq ft - r 1 1 43,441 gq ft - p a LOWEST ELEVATION OFA FENCED AREA AS TO PREVENT PONDING BEHIND SILT FENCES THAT EXCEED 1.0 FT. / ; ' / 1.38 ac I - - I , I 1.00 ac - , - - y - a" f �,/ , /` JUDITH B. ZIMMER ) 610 j / , - \ LIMITS OF DISTURBANCE I , , , ' ` / f o TAX PIN: 06-027-049A LOT: 4. �L0T�3 LOT : 2 / � ;/ �' �D ` ' LPT :,6' - /' 43,3Q6sq ft- 40, 122 sq'ft, 4374 sq ft ;,' 1 BK. 1747-130 - - 5 3 2 s ft �� 95 ac PART OF TRACT 6 - 5 q - _ _ _ - ¢ 99 ac 0.93 �c / O J GROUND STABILIZATION Site Area Description Stabilization Time Frame Stabilization Time Frame Exceptions Perimeter dikes, swales, ditches 7 days None and slopes 1,161,310 Square Feet Z High Quality Water (HQW) Zones 7 days None PROPOSED HIGH HAZARD SILT FENCE C If slopes are 10' or less in length Slopes steeper than 3:1 7 days and are not steeper than 2:1, 14 5 Minutes 541 18,154 days are allowed. Slopes 3:1 or flatter 14 days 7 -days for slopes greater than 50 Q10 93.71 CFS feet in length. All other areas with slopes flatter 14 days None (except for perimeters and than 4:1. 23,591 64,141 HQW Zones) * "Extensions of time may be approved by the permitting authority based on weather or other ite-specific conditions that make compliance impracticable." (Section II.B (2)(b)).Ii PLAT CAB. K, FILE 722 . _ / -%29 ac- ; , '/ j / . I ,- -,,.- ' _ , I -; I �,,, II _ -, I -1 -o,, -I,- ,w,- _- ,% -- 1 , -_- ' , �.\I- _-I�I�-I- . -O , -,1- I1 I- -_f - .% I --�- -"I , . , ,,--. 'tII -- I- I- I_I " ----,I!�,-1�-,-, _-- ,_- � - __I�,, ---I,%% ,I I I-. , - - '' I - -,, _- -I-II --,,/- I ,-� /' - b , , " NOW OR FORMERLY _ __ f �_ ' l �/ d/ II1 - I# ---,-I--- I ---- , ,,\I_I \ ' \I- -- -- --- , -I'\ - - I I' I1- . , �,l" III-� I I&, , II -I --,, I ,, � I- ,VI �; II -I ,I "J/I- ,0 , ,-I -10 ',, -I I- :rI.,, I- -- M -\- , " I -I -I-- ,,,- I--:-/ ,- Z NE:R 40 I' ! I I wo. II " JI. 0,II, 4 ,\/,' /_ USE RESIDENTIAL - 'N , / ' - A-/ _ I \ I _ ' I . �I 1 / -1 TOTAL DISTURBED AREA = 9.99 AC -= = - f , 4 Nod JOHN H. HUCKERT, JR. 4,-m - " / ' _ BK. 6354, PG. 141 , , / \ . , I. 586 _ , � - - =- I " TAX PIN: 06-027-006 LOT : 7 hr a ,� OPEN SPACE: d7 CHARLES B. BAUCOM _ /40,948 sq ft , , , - - , 8,546 sq ft NOW OR FORMERLY TAX PIN: 06-027-048 '' 0'94 ac - _ _ ZONE:R-40 /' ` ' / r , 0.20 /ac USE RESIDENTIAL TRACTS \ - _ _ _ - _,% " / J ,Q PLAT CAB. K, FILE 722 ' , I / 1 8 - , ' / NOW OR FORMERLY , ' \// \' / , ', - ; l y ZONE:R-40 I- -, \ \ ,LOT: : 8' \ 1,6"45,045 Oft. ' 1' , ' 1 , , � � USE RESIDENTIAL `� 40,861 sq ft,' ,'42,35t'acres' _ 1 �- - NOTE: SLOPES STEEPER THAN 3:1 SHALL BE STABILIZED WITHIN 7 DAYS. L/ 0.9 ac ' ,e' j _ - - / LOT : 2� - ' SLOPES 3:1 OR FLATTER STABILIZATION SHALL BE PROVIDED WITHIN 14 DAYS. \ q/ 4,�,35s s 'ft /I" , �o . ,LDT : 9� 1I - - - - - - - _ _ \40,4sq-ft" _ / �OT:.4 ,'( - ,I, I - - p' , ' I If. , BLAIR BURKE / \ � 0.94 ac f, < 41,99$s q ft' LOT .' 27 / /h0 �� BK. 7100-160 • < _ I r _ - - f7 ' - 3 , , , , 0.96 ac , \ LOrt . ;1 TAX PIN: 06-030-014A - I • , - - - - - i -t,I"LOT : 25 / 40 1 0 ft . TRACT 2 . - _ _ - , -I , 41, 071 sq h ' 41 930 Sq ft PLAT CAB. N, FILE 524 �- , • , , . --- LOT : 10_ _ ! 59� / , - Y " - f ' 0.94 ac , , b,96 ac/ , / ' �. _/t'' ' % JUNE MOORE ' DOROTHY MOREE NOW OR FORMERLY , ' , , L • _ I _ - 40,987 - ftp I - ' - _ -� PROPOSED SILT FENCE (TYP) ' , ,' I / /" � ; / , ' ' , ' BK. 6403, PG. 115 ZONE: R-40 \ q _ / -' 1596 - USE: VACANT` ` C . _ /O.�c ` \'\/ I ` -I 'N / ,'I / , / I % ;' PLAT 6-520 F f S90 TAX PIN: 06 027-010 o - - - - ' , I ' / , / NOW OR FORMERLY I ! LOT : 23 \ ZONE:R 40 I , ' , - _ - � - - _ _ / '- - 40,248 sq ft,' ' , ,,�, ' roo/ , ' \ I �y USE RESIDENTIAL Sg _ 41,000 sq ft 0.92 ac \ ' 1/2 IRj / JACK CASE , / k 5 G \,\"",C _\ - _ 1 �. -/ BK. 7071-403 \' , , . \ - , , ) , TAX PIN: 06-030-0148 ,//t" \ �^ LIMITS OF DISTURBANCE , / , , � 1 i \ . - ' , - _ / ;„ -\: ' I PLAT CAB. N, FILE 524 \' s�o ;� \ 1 RAN / \ I 1 t`:' /� ,' `, NOW OR FORMERLY ' , - LCTT . \ r;\Y ` i' /' \' ' , - _ -- - 155,431 sg ft - ,' /� I ZONE:R 40 \ 50,859 sq ft` ,/I p \ ' \ � , /, o 3.57 ac LOT . 22 �, { \\ USE: VACANT \' �' : �� _ _ - 1.17 ac - 5� 48,262 s ft �,, , \ I L,. '/ ", j fi PROPOSED STONE OUTLET / \ � 1 y ' ( .; 1''``0,701 sq\ft', C \ '\ ' __ \ ----- -:=% VI I- , I \, , \ , DAVID E. BALLENGER ti % \ �! \ \ �� / 1, I , _ , _ _ - _ ' _ - - - - ' - - /' �,'1 LOVELL FAMILY - '' i;' BK. 602-107 ( `,`, \ `' �/ -'' "'' _ 80� _� ; I LIMITED PARTNERSHIP TAX PIN: 06-030-002A I - - l ' . . , - _ / � �- ' \ ' , , � - - \ - - l 5- - ' . J ' BK. 1488, PG. 821 NOW OR FORMERLY • . ,1�' \ , � • _ - " ,'� _ , - - \ - _ _ _ - - - - �, ; " '; , TAX PIN: 06-027-007 ZONE:R-40 _ \ ,- , , LO 14 l - - _ _ - - % ' , , . - - - - _ _ _ _ . _ - - _4: _ _ _ - r ,\ NOW OR FORMERLY USE: VACANT 40 56q ft 5 LOT ' 21 %� UNINCORPORATED LEGEND -ELEV- EXISTING CONTOUR ELEV PROPOSED CONTOUR TD TEMPORARY DIVERSION DITCH ■ � LIMITS OF DISTURBANCE - BASIN DRAINAGE AREA PROPOSED SILT FENCE 0�q0q__ftW:b§l ' - ,- \� `` ; �,. -h 1, l `\ \_ MICHAEL DAVIS TAX PIN: 06-030-0028 NOW OR FORMERLY ZONE: R-40 USE: VACANT 0.93 ac - ,Q ` - - _ :/ >.", /. , ; UNION COUNTY 40,291 soft s o / . 0.92 ac ` \ 570 f ,, ' _ _ - (' ' \ `rU_ \ • . \ J ' \ - - ` MARK J. ROSENBLUM - - - _-- - '� - - f 1p ' , &KATE K. ROSENBLUM PROPOSED BAFFLE (TYP) ,/ OPEN SPACE ,' ' \ ; PROPOSED DOUBLE ROW SILT FENCE = _ _ / l 71,807 sq ft �- ; • ` i = BK. 550, PG. 851 \ _ / \` i 1.65 ac ' _ � ., ., TAX PIN: 06-027-005A -- � - : �-, i, \ s - NOW OR FORMERLY i - /'„ ' ` �s -LOT: 15. PROPOSED 32' WIDE RIP -RAP SPILLWAY 46,040, sq ft ZONE:R-40 -, 6 - , � 'Q.92 ac - ' - , /'. --� USE RESIDENTIAL = j- ---_ - 5 - SPILLWAY EL = 550.00 c J \ s `I �o-.- I .- I II . r -- ' I io- ,. "- A,II - _ ; . "-'<-,. - .., ,I _ _ - ,, 'L -- ---,II,' . I � " � - -K-, I- - - - ,I ,I- -I�. "/ I, _ _ -II-I--IJI -- ,- -0 ,- I,- I \ ---,-- 0,- ,I-- _ - -" I- - -,- 11.,-. " , - ,-- , ,- _ _ - - - - - - - 11 ' \ �I \ o \S 1 •- r- _; --- _:-- - j ------- -------- --__ __' - \ *\ 60\ / LOT: 20 , - " -. - -, _ - ^ -,I/,- , ,),- ,- II,I1, 1 , 7` 4,'137 sq fi' ` - / ' - ;/` /i Q / c 0.99 ac f�4j: = _ _ / _ /;, \ ' �' .572 ,, 1P,S-1-1-�' _ \-'3-, f , _ ��_L �-Ift1_I 1 ,_-, _ ftII,-- _ I, -_- I- --:- �I,., I ".. -II,_- I� I - - - - - - /, ;. , / - I I II q„ , /' , --, - -- I ,I --__,_-/ --_- ,_ --- - _;> - -_--_ I - _I _, I\ _-_ 113 -' i \ I _ 0.9 ac , ' : rOT : 19 -_ _ _ _ - \ III, , 1 1 -I11 ffI - z.- - I, I -I __I , I ,-I' \ - - - - I 11I _tI._ 0I I --I I ,-"- I I I - _- -_- -I I �I I --, _,I _I -- II -II " - -�I I.- I- - ,- I �- I�I >I0 -e1 -- -- ­_, - 0 _--, - I -, -_, - I/- - --1,1 , > - ,III -.-I-,I, - I ,, �I_ ,- I I ,I/-�-, , _- I -_ I , _- 1-, - _- 6-.-:I, ,;;,-z_�:. -_---_-'� _-- !:EZ -,I =-x-_-.- 1 I -8 _- /I _---_---: _- -- : t- 5,, - ,4I�. ,.,. -8:, : -:-_I_.I, . -,U,� .�'_I .- "I"I,"I:,p'.�1-,,' , -41,�,I"11 ,�:--I�:' "I:- , �,,"� �- I ,,, : , "- ,1, ,_-V- ,�,7 .: - I )l,, )- \-" f1- /II cc-_ /' �,' 552.91' PROPOSED 4 z4' (INSIDE) CONCRETE RISER \ 0 45,589 sq \_ - HV -3 TN ON PENINSULA WITH TRASH RACK ON BALLAST PAD, WITH I , \ 1.05 , L , /; / PROPOSED FAIRCLOTH SKIMMER I , I _ - •\ LOT,: 17 I _ ' ' - , (USE PERMANENT STRUCTURE &ATTACH . \ %. _ 4 , 71'sq ft- - _ _ _ /11Z1 - SKIMMER TEMPORARILY -SEE DETAIL ON C-3.7) - I ,_ J `�� - _ _ _ = ` _092 as` . ' ` _ _ I LOT: 98 - ' ' _ _ - _I ' J, ', - �- 1/2`4441 ' - _ • '# , PROPOSED 24" RCP BARREL @ 0.50% h� h -� - _. 0.92.ac PROPOSED RIP RAP `� PROPOSED - -' . , _ _ - " - - . // / ^ ' ' DOUBLE ROW - \ \ �" • _ - _ - ' V - ' i- /- - / , ST ' \ SILT FENCE ---�C�\ 1/2"NFR - ,,I I ' j - VD EX.18" S S. - 546, _`�� �\ \_ _ / / % , <_ \. h _ mss \ _ \ - , 1" S.S. % ! _ S.S.-�_ - - '- I 1) PROPOSED SILT FENCE - _ _ - `- - = �� -ss �, C= OUTLET -' - ' - - = - - _._ 1-- . _ -----_ss - _ _ \ \ \ - _ ' = `- = 1/2"NIR _ - - -' \1 SKIMMER BASIN 3 \ _ \ , L _ AT0+20.00' 11 �), _ i= DRAINAGE AREA (C=0.50) = 26.66 AC - - EAST FORK OF = - = - _ _ - TOP OF BERM ELEVATION = 551.00 -- -= _ �- ` =- �'�' , ` _ TWELVE MILE CREEK ; 1_ _ _ ' - II I II SPILLWAY ELEVATION = 550.00 _ \ _ _ �,�� j = RISER WEIR ELEVATION = 549.00 \ \ \ \- _ - _�,_• ', ___ _?� '•` - CLEANOUT ELVATION = 542.50 - BOTTOM OF BASIN ELEVATION= 541.00 REQUIRED VOLUME (cf) = 41,076 \ PROVIDED VOLUME (cf) - 278,573 ____- SPILLWAY SPILLWAY LENGTH (ft) = 32.00 RISER = 4'x4' (INSIDE) CONCRETE RISER \ BARREL = 287.10 LF 36" RCP @ 0.70% SKIMMER SIZE = 6" \ ORIFICE SIZE = 6" LOFAMILY \ LIMITEDD PA PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY ZONE: R-40 USE: VACANT \ �- - - _ _ - - -I �_ r` - �_.�_ GRAPHIC SCALE 0 100' 200' ( IN FEET) 1 inch = 100 ft. Project Project # Designation SKIMMER CAVESSON 6198 SKIMMER BASIN 3 BASIN Client BOWMAN Date 5/28/2018 Designer KEW EN GSI NEE RI NE %4� 2013A Van Buren Ave. Indian Trail, NC 28079 O �O cn INC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 26.66 Acres 1,161,310 Square Feet Z Total Disturbed Area 9.98 Acres 1 434,729 Square Feet PROPOSED HIGH HAZARD SILT FENCE C PROPOSED INLET PROTECTION IPROPOSED TEMP. CHECK DAM 0.93 ac - ,Q ` - - _ :/ >.", /. , ; UNION COUNTY 40,291 soft s o / . 0.92 ac ` \ 570 f ,, ' _ _ - (' ' \ `rU_ \ • . \ J ' \ - - ` MARK J. ROSENBLUM - - - _-- - '� - - f 1p ' , &KATE K. ROSENBLUM PROPOSED BAFFLE (TYP) ,/ OPEN SPACE ,' ' \ ; PROPOSED DOUBLE ROW SILT FENCE = _ _ / l 71,807 sq ft �- ; • ` i = BK. 550, PG. 851 \ _ / \` i 1.65 ac ' _ � ., ., TAX PIN: 06-027-005A -- � - : �-, i, \ s - NOW OR FORMERLY i - /'„ ' ` �s -LOT: 15. PROPOSED 32' WIDE RIP -RAP SPILLWAY 46,040, sq ft ZONE:R-40 -, 6 - , � 'Q.92 ac - ' - , /'. --� USE RESIDENTIAL = j- ---_ - 5 - SPILLWAY EL = 550.00 c J \ s `I �o-.- I .- I II . r -- ' I io- ,. "- A,II - _ ; . "-'<-,. - .., ,I _ _ - ,, 'L -- ---,II,' . I � " � - -K-, I- - - - ,I ,I- -I�. "/ I, _ _ -II-I--IJI -- ,- -0 ,- I,- I \ ---,-- 0,- ,I-- _ - -" I- - -,- 11.,-. " , - ,-- , ,- _ _ - - - - - - - 11 ' \ �I \ o \S 1 •- r- _; --- _:-- - j ------- -------- --__ __' - \ *\ 60\ / LOT: 20 , - " -. - -, _ - ^ -,I/,- , ,),- ,- II,I1, 1 , 7` 4,'137 sq fi' ` - / ' - ;/` /i Q / c 0.99 ac f�4j: = _ _ / _ /;, \ ' �' .572 ,, 1P,S-1-1-�' _ \-'3-, f , _ ��_L �-Ift1_I 1 ,_-, _ ftII,-- _ I, -_- I- --:- �I,., I ".. -II,_- I� I - - - - - - /, ;. , / - I I II q„ , /' , --, - -- I ,I --__,_-/ --_- ,_ --- - _;> - -_--_ I - _I _, I\ _-_ 113 -' i \ I _ 0.9 ac , ' : rOT : 19 -_ _ _ _ - \ III, , 1 1 -I11 ffI - z.- - I, I -I __I , I ,-I' \ - - - - I 11I _tI._ 0I I --I I ,-"- I I I - _- -_- -I I �I I --, _,I _I -- II -II " - -�I I.- I- - ,- I �- I�I >I0 -e1 -- -- ­_, - 0 _--, - I -, -_, - I/- - --1,1 , > - ,III -.-I-,I, - I ,, �I_ ,- I I ,I/-�-, , _- I -_ I , _- 1-, - _- 6-.-:I, ,;;,-z_�:. -_---_-'� _-- !:EZ -,I =-x-_-.- 1 I -8 _- /I _---_---: _- -- : t- 5,, - ,4I�. ,.,. -8:, : -:-_I_.I, . -,U,� .�'_I .- "I"I,"I:,p'.�1-,,' , -41,�,I"11 ,�:--I�:' "I:- , �,,"� �- I ,,, : , "- ,1, ,_-V- ,�,7 .: - I )l,, )- \-" f1- /II cc-_ /' �,' 552.91' PROPOSED 4 z4' (INSIDE) CONCRETE RISER \ 0 45,589 sq \_ - HV -3 TN ON PENINSULA WITH TRASH RACK ON BALLAST PAD, WITH I , \ 1.05 , L , /; / PROPOSED FAIRCLOTH SKIMMER I , I _ - •\ LOT,: 17 I _ ' ' - , (USE PERMANENT STRUCTURE &ATTACH . \ %. _ 4 , 71'sq ft- - _ _ _ /11Z1 - SKIMMER TEMPORARILY -SEE DETAIL ON C-3.7) - I ,_ J `�� - _ _ _ = ` _092 as` . ' ` _ _ I LOT: 98 - ' ' _ _ - _I ' J, ', - �- 1/2`4441 ' - _ • '# , PROPOSED 24" RCP BARREL @ 0.50% h� h -� - _. 0.92.ac PROPOSED RIP RAP `� PROPOSED - -' . , _ _ - " - - . // / ^ ' ' DOUBLE ROW - \ \ �" • _ - _ - ' V - ' i- /- - / , ST ' \ SILT FENCE ---�C�\ 1/2"NFR - ,,I I ' j - VD EX.18" S S. - 546, _`�� �\ \_ _ / / % , <_ \. h _ mss \ _ \ - , 1" S.S. % ! _ S.S.-�_ - - '- I 1) PROPOSED SILT FENCE - _ _ - `- - = �� -ss �, C= OUTLET -' - ' - - = - - _._ 1-- . _ -----_ss - _ _ \ \ \ - _ ' = `- = 1/2"NIR _ - - -' \1 SKIMMER BASIN 3 \ _ \ , L _ AT0+20.00' 11 �), _ i= DRAINAGE AREA (C=0.50) = 26.66 AC - - EAST FORK OF = - = - _ _ - TOP OF BERM ELEVATION = 551.00 -- -= _ �- ` =- �'�' , ` _ TWELVE MILE CREEK ; 1_ _ _ ' - II I II SPILLWAY ELEVATION = 550.00 _ \ _ _ �,�� j = RISER WEIR ELEVATION = 549.00 \ \ \ \- _ - _�,_• ', ___ _?� '•` - CLEANOUT ELVATION = 542.50 - BOTTOM OF BASIN ELEVATION= 541.00 REQUIRED VOLUME (cf) = 41,076 \ PROVIDED VOLUME (cf) - 278,573 ____- SPILLWAY SPILLWAY LENGTH (ft) = 32.00 RISER = 4'x4' (INSIDE) CONCRETE RISER \ BARREL = 287.10 LF 36" RCP @ 0.70% SKIMMER SIZE = 6" \ ORIFICE SIZE = 6" LOFAMILY \ LIMITEDD PA PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY ZONE: R-40 USE: VACANT \ �- - - _ _ - - -I �_ r` - �_.�_ GRAPHIC SCALE 0 100' 200' ( IN FEET) 1 inch = 100 ft. Project Project # Designation SKIMMER CAVESSON 6198 SKIMMER BASIN 3 BASIN Client BOWMAN Date 5/28/2018 Designer KEW EN GSI NEE RI NE %4� 2013A Van Buren Ave. Indian Trail, NC 28079 O �O cn INC Erosion and Sediment Control Planning and Design Manual Total Drainage Area 26.66 Acres 1,161,310 Square Feet Z Total Disturbed Area 9.98 Acres 1 434,729 Square Feet Co -t=, C 0.50 Contour Area Volume Net Volume Tc 5 Minutes 541 18,154 0 0 110 7.03 Inches per Hour 542 20,250 19,202 19,202 Q10 93.71 CFS 543 22,445 21,347 40,549 E 544 24,738 23,591 64,141 Required Volume 1 35,928 Cubic Feet 545 27,130 25,934 90,074 Required Surface Area 1 40,764 Square Feet 546 29,620 28,375 118,449 m O Q 547 32,198 30,909 149,358 Provided Volume 1 278,573 Cubic Feet OK 548 34,848 33,523 182,881 Provided Surface Area 41,762 Square Feet OK 549 37,566 36,207 219,088 550 40,348 38,957 258,045 550.5 41,762 20,528 278,573 Length 417 Feet Minimum Spillway Design Width 176 Feet Q10 93.71 CFS L/W Ratio 1 2.37 1 H 0.5 Feet C 3 Spillway Elevation 550 Surface Area at Spillway 1 40,348 L 88.35 Feet Spillway Design Spillway Length 32 Feet Days to Drain 5 Days Head over Spillway 1 Feet Skimmer Size 6 Inches Weir Coefficient 3 Radius 3.0 Inches Max Flow 96 CFS 77_Orifice OK Orifice Diamter 6.0 Inches LU M O 00 � J O �O cn m 73 W(_11 O O OCDM >_ Z CCI f M -, N Co -t=, N Q U Q 0 W Zth Z W W 0 0 � >_ Z � z �, UZ (3-, aa)i Q J Q N N E ZUJ Z : N m 'M 00 WW > Z R J W C) Q M �_ m O Q -a o Z 2 N Qrvn LU Q� 7 00 � J m ° m 73 O 0C w U >_ M N O LU00 U IJ Y o _N Z Z Lb = � W CL Q W J U U Z 11L z Z LU 0Qw O JJ m J W `� � z 5 UJ w wzU) � o - Z Q ``z U LU U O Q T- z LLIO �Q0Z) Q (n '<t O Sheet C-3.1 Q� 7 00 � J m ° m 73 O 0C w U z m O N O LU00 U IJ Y o _N Z i:�m = � >_ Z � L, r^ `1) O Q 0 ZUJ z J W C) m O Q Z 2 Qrvn Sheet C-3.1 WWA ���♦ • ZOA u h -WIN OIRA% m , L Q) ? ' , " (( LOVELL FAMILY BK. 602-107 TAX PIN: 06-030-002A MICHAEL DAVIS TAX PIN: 06-030-0028 NOW OR FORMERLY ZONE: R-40 USE: VACANT WESLEY OAKS HOA BK, 4384-523 TAX PIN: 06-048-323 NOW OR FORMERLY I \ ZONE:R-40 ROY &MELISSA HALL 110 USE: COMMON AREA BK. 4461-613 i X 588.15' TAX PIN: 06-027-042 HV -6 PKS AT COR DW NOW OR FORMERLY / MARLENE LYONS ZONE:R-40 TRUSTEE USE: RESIDENTIAL BK. CS13-496 TAX PIN: 06-027-042A NOW OR FORMERLY ` ZONE: R-40 \ \ Cy USE: RESIDENTIAL RICHARD KAPITAN � ft01O� BK. 6012-624 DD Rp RICHARD PITAN TAX PIN: 06-027-0048 mow_ , qp ,NOW OR FORMERLY w_ PBK. 6012-624 ZONE:R-40 ` vsk iC '^ , TAX PIN: 06-027-0048 \ USE: RESIDENTIAL w \ �\ _ j IA NOW OR FORMERLY BENTON EDWARDS w_ _ ` ZONE:R-40 BK. 734-397 v'_ ` USE: RESIDENTIAL O TRACT 1 tl PLAT CAB. D, FILE 583 BENTON EDWARD` � � —W_ TAX PIN: 06-027-044 BK. 920-782 ` —w, �• ,� LANDON MUNDY NOW OR FORMERLY TAX PIN: 06-027-043 ft, w_ BK. 6900-413 ZONE:R-40 NOW OR FORMERLY TRACT 2 USE RESIDENTIAL PLAT CAB. D, FILE 583 �� 6�� 596 _ - — w TAX PIN: 06-027-045 ` (O — — NOW OR FORMERLY _ Td62-USE ZONE:R-40 , ,' _ - - _ • � _ ', ., ` , RESIDENTIAL I TARRUS GRAVELLY SILTY CLAY LOAM. SLOPE: 2 TO 8 PERCENT �O DEPTH TO RESTRICTIVE FEATURE: 40 TO 60 INCHES TO PARALITHIC BEDROCK JUDITH B. ZIMMER 1 610 TAX PIN: 06-027-049A BK. 1747-130 l I / PART OF TRACT 6 PLAT CAB. K, FILE 722 NOW OR FORMERLY ZONE:R-40 USE RESIDENTIAL No,d Nc" JOHN H. HUCKERT, JR. l \ / BK. 6354, PG. 141 \ TAX PIN: 06-027-006 NOW OR FORMERLY CHARLES B. BAUCOM / ZONE:R-40 TAX PIN: 06-027-048 / \ USE RESIDENTIAL TRACT 5 l , PLAT CAB. K, FILE 722 NOW OR FORMERLY ZONE:R 40 \ 1,8,045 sq. ft. USE RESIDENTIAL / \ ; 42. \ acres / BLAIR BURKE BK. 7100-160 TAX PIN: 06-030-014A / TRACT 2 _ _ _ _ PLAT CAB. N, FILE 524 NOW OR FORMERLY �\ \ ' / JUNE E - � MOREE \ \ BK. 6403, PG. 115 DOROTHYY MO USE. VACANT \ / / / \' , _ I 6 PLAT D-520 cri 59C3 TAX PIN: 06-027-010 / I NOW OR FORMERLY \ ; / ZONE. -R-40 RESIDENTIAL JACK CASE w BK. 7071 -403_ - TAX PIN: 06-030-0148 I TRACT 3 ri PLAT CAB. N, FILE 524 s�o �, I ` NOW OR FORMERLY 155,451 \ ZONE:R-40 3.57ac \ 1 USE: VACANT ',`�,• _ , � , � - ----- --- --_--- Bd62- � ' s90 -_ "• - � , \ BADIN CHANNERY SILTY CLAY LOAM. SLOPE: 2 TO 8 PERCENT ` DEPTH TO RESTRICTIVE FEATURE: 20 TO 40 INCHES \ , DAVID E. BALLENGER 7 � m m i TO PARALITHIC BEDROCK, 40 TO 80 INCHES Q) ? ' , " (( LOVELL FAMILY BK. 602-107 TAX PIN: 06-030-002A ti r^ r Y TO LITHIC BEDROCK J l - LIMITED PARTNERSHIP BK. 1488, PG. 821 NOW OR FORMERLY o 0 �� /NOW \ _ l — 1 TAX PIN: 06-027-007 ZONE:R-40 i O = v) m ( z 'm Q / USE: VACANT \ ` UNINCORPORATED 1 \ UNION COUNTY MARK J. ROSENBLUM 570--. _; \ & KATE K. ROSENBLUM- 4�1� ,' BK. 550, PG. 851 , TAX PIN: 06-027-005A NOW OR FORMERLY - - - - - - - I„ ZONE.R-40 560 USE RESIDENTIAL \ - j - 000 4 sq ft 0.99 ac j OPE CE 1,321 sq 8. 570 18" ,S ke V1 ChA- - - _ CHEWACLA SILT LOAM. SLOPE: 0 TO 2 PERCENT = - - EAST FOR, OF _ ' ' _ DEPTH TO RESTRICTIVE FEATURE: MORE THAN 80 TWELVE MILE CREEK - - INCHES ` LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY ZONE:R-40 0 100 USE: VACANT ( IN FEET ) 1 inch = loo ft. rn 0 0 Lo M 0 m � M o O lz c U Q W 4t W E 0 W z U� Yu - Q N N Q� LQ) Z N 10 z00 c� WW z o M -C3 Q) N W 7 � m m m Q) ? m CL ti r^ r Y 0 J O 0 z __j W C Q W J U ZCl- CL Q w J J m J Lu w w z o-� `` z uj uj O J_ m .��•�,�CARp" j; S ''•,!GIN �O� 5/28/18 Sheet C-3.2 7 � m 0 m Q) ? CL r^ r Y 0 J N 0 m o 0 W Y O = v) m Cf) z 'm Q C/) .��•�,�CARp" j; S ''•,!GIN �O� 5/28/18 Sheet C-3.2 3 59( 57,' 1+nn 2+nn +nn 4+nn 5+nn e+nn 7+nn �11T17 A+nn A+sn 1+00 2+00 1 604 o ' 0 CB 123 \ \ \ I OS \ IN / X 3+00 4+00 5+00 rn 0 / 6+00 J LU Sapp / M � A RCP 502 2p„RCA` VL. x Q O OOM w m � M CB -120 \ 0 Q p CB� 121 30” RCP ^h U C Q v J L f Y o0 N III �+ LU W 10 DI -144 `• 6 n S82 2 Q) DI -119 p Q) W � Co m—Ca m 0 Q 9 o Li z om Q) O N -169-01. OWPTS ?l OW PTE EV: 581-35 PVI ST :5+01.21 1 :1141 1=1 1=14 583 53 0 EX. GRADE CIL PVf EL V.580. 15 K:3 .00 HI H PT STA: 6+70.32 LVC: 180.00 OW PTS A: 8+35.6 \ \ N N rn LVC:12 .00 PVI ST :8+50.89 \ \ �S„ \ PROP. GRADE CIL Co ao + vi w rn + vS W w N M M o C14 CN Ll LU coN PVI EL V:579.92 LVC: 50.06 m W NF, \ X00 w moo / Natio LXGRADE RT _±4"RCP — 30" RCP 36" RCP — — C7 w co �F c6 0)M 0 CD w w O 0) N N c6 C's m 0 0 w w O Ln N M N � rn Co CD CD w w O co N 00 C6 <Y 00 00 CD CD w w O Ln N Lo 4 o 00 00 CD CD w w o Lo O N 00 00 0 0 w w Co O �— Lo N 00 00 0 0 w w oo 0)1- O N N 00 00 0 0 0 w w w o O Co Ln � 00 00 00 1+00 2+00 1 604 o ' 0 CB 123 \ \ \ I OS \ IN / X 3+00 4+00 5+00 rn 0 / 6+00 3k CN ELTA=86'03'36" — Sapp / M � 7+00 OPEN SPACE: 107 / 8,546 sq ft / / LOT: 28 / LOT: 27 0.20 ac 43,358 sq ft 40,130 sq ft CB 122 , I e 9+00 .I • 75 1.00 ac 0.92 ac , 5g6 / \ 1°g w, / / 5g0 26 . 41,930sq ft DI 143 / 0.96 ac / 1� 4---- U 0 R=300.000777– L 450 618.13'17 E 409.43'Ca �� rn 0 / 3k CN ELTA=86'03'36" — Sapp / M � A RCP 502 2p„RCA` VL. x Q O OOM w m � M CB -120 \ 0 Q p CB� 121 30” RCP ^h U C Q v J L f Y o0 N III �+ LU W 10 DI -144 `• 6 n S82 2 Q) DI -119 p Q) W � Co m—Ca m 0 Q 9 o Li z / - LOT: 25 41,071 sq ft = = 0.94 ac - - - - - - - - - - - CB -117 GQ \ DI -140 ' LOT: 1 43,441 sq ft LOT: 2 1.00 ac 41,374 sq ft / 0.95 ac A --------- -- L=196.312, R=250.000 ri► Q CB-139,Z(S8� CH= S2°18'47"W 191.31' N LOT: 3 \ 40,422 sq ft 0 / \ 0.93 ac 590 / LOT: 4 \ \ / 43,306 sq ft / 0.99 ac / l` CB -114 584 CB -112 CB -113 i 586 / - - - �,, ------ --- - --- ,__-- 590, / 1 590 — 1 y LOT: 5 LOT: 6 59,984 sq ft 1.38 ac 56,352 sq ft 1.29 ac - - - - - - - - - VERTICAL SCALE ( IN FEET ) 0 1 inch = 4' ft. U-1 GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 4o ft. w rn 0 M o O m � M � � z m �5% x Q O OOM w m � M 0 Q p _ 4J U C Q v J L f Y o0 N III �+ LU W 10 lo -- o Z a) U ai � 2 Q) Q) W � Co m—Ca m 0 Q 9 o Li z om Q) O N w cj� M Co m � W W = � z m m w 0 O z O O J W � CL z W J U U �CLz z �- oQw LU J J J LU w wzU) Lo uj co QD O J m < CA �l = 14 _ GINEE�� 5/28/18 Sheet C-3.3 cj� M m o m � W W = � z m U O O 4 v J L f Y o0 N III �+ m O U o w 0 W � m 0 Q Li z om Q) < CA �l = 14 _ GINEE�� 5/28/18 Sheet C-3.3 3 59( 58( 57( 56( 55%' RMTI1 F E'M] MOMBOB] M'1IT17 MEM -101 GLAMT11 GF:PlIT17 GrOlIT11 Fr.sMTf�r.sMM i90 rid 70 i60 i55 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 572 LOT: 22 / \\ \ 1 , CB -124 48,262 sq ft am / \\ 1 CB -132 I 24" RCP 1.11 ac a I +82-04 LOT: 16 40,240 sq ft / LOT: 23 oo ^ ry� 0.92 ac 40,248 sq ft ^ i 0.92 ac / ; DI -133 / I PC: 1+04I ^ OPEN SPACE M f2 ,07 I Lo. 71,807 sq ft 1 LOT: 24 / \ S 50' R/W 1.65 ac J / 41,998 sq ft 8p �h 580 0.96 ac R/VV I L=58.389, R=300.000 / 50 RIW 155,451 576 S�6 CH= S14°3625"E 58.30' CB -103 48"RCP ` 3.57 ac _ - _ DELTA=11°09'05" N S) A ~ 48" RCP 0 Q 566 CCB -139 582 578 574 cfl �� /�V r O CB 102 SS 580 `� 3'82 L=196.312, R=250.000 582 M - _ _ � 0 `ti CH= S2°18'47"W 191.31'T.. p CL h DELTA=44°5929" N 584 M _ �. Q - N 586 CB -109 s, 16+00CB-1o6 +00 CB 104 2 14+00 CB -107 h^�` sq" S I 6a 12+00 �, 13+00 S20° 10' 57"E _ o 42" RCP - — — _ ��� 01' S2'E U 18-1.00 \ 68 p 10+00 - -- 11--00 h� 42" RCP ; 42"RC= .32 STA: 18+32.25 (RO D 1) • 603.56' � - q`� 42" RCP _ STA 8 53 ) •• Lo 2„RC ted, saw 42” RCP i v `• — S84 CB -108 CB -114 - �- s' - _ 57 OAD CB -105. ro LOT: 15 _ ° 582 STA: 14 79.58 (R 4 _ ,• _ - - _ _ _ � - - 580 578 S�6 U 510 40,040 sq ft CB -111 ,b• , < _ _ 584 CB 110 STA: + r' 570 0.92 ac °• — 586 \ \ � 0 58 586 CB -113 CB -112 590 59 _ 4 I �� CCB -135 s' / I _ '� 572 590 I F- ----------- — ISI I . ..........f p, 590 \AI \ LOT:6 ., �'moi 56,352 sq ft al 1.29 ac c a w 580oo I 576 00 I I �C, I O LOT : 1� 1 696 I I LOT: 12 I ti 40,569 093 ac ft 50858 sq ft LC I\LOT: 11 1.17 ac I 40E LOT: 10 I 41,000 sq ft I / LOT: 9 40,987 sq ft N 0.94 ac ° 596 LOT: 8 40,974 sq ft 0.94 ac I o I 578 LOT: 7 40,961 sq ft 0.94 ac L90 40,948 40,948 sq ft 0.94 ac I CB -136 I ► I I 0.94 ac VERTICAL SCALE ( IN FEET ) 0 1 inch = 4' ft. GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn O o O O O cc o m L M � m � T m x Q O OUM W z EX) � M Q PVI SA:11+32. 71 O J— z Cc o -Z o O U c Q I'' W Lu W E z a� °' U � W `t � = HIGH P STA: 11 + 4.63 m � -No cB 0 w z Lu Q) m O N HIGH P ELEV. 587.09 L :176.27 EX. GRADE RT - EX. GRADE CIL o Lf Ucc— U m W PROP. GRADE CIL EX. GRADE L \ 15" RC \ 28 0 \ 42" RCP \ \ 42" RCP 42" RCP — — — — — 15" RCP 42" RCP \ — — 42" RCP \ — 42" RCP 42" \ — RCP 42" RCP U C7 w O Lo 0 C7 C7 u- w O ct O - r; Co 00 C7 C7 u- w rn o ca � co co Co co C7 C7 u- w � r-_ M M co cn Co co C7 C7 u- w r\ O Lq o Co Co r\ C7 C7 u- w O co r,- �t Co r\ 0 CD u- w N "t Co o r\ r\ CD CD u- Lu Lo M 0 "zt N r\ r\ CD CD Li-w o N O N o N rl_ CD LL O N ai ca ` i90 rid 70 i60 i55 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 572 LOT: 22 / \\ \ 1 , CB -124 48,262 sq ft am / \\ 1 CB -132 I 24" RCP 1.11 ac a I +82-04 LOT: 16 40,240 sq ft / LOT: 23 oo ^ ry� 0.92 ac 40,248 sq ft ^ i 0.92 ac / ; DI -133 / I PC: 1+04I ^ OPEN SPACE M f2 ,07 I Lo. 71,807 sq ft 1 LOT: 24 / \ S 50' R/W 1.65 ac J / 41,998 sq ft 8p �h 580 0.96 ac R/VV I L=58.389, R=300.000 / 50 RIW 155,451 576 S�6 CH= S14°3625"E 58.30' CB -103 48"RCP ` 3.57 ac _ - _ DELTA=11°09'05" N S) A ~ 48" RCP 0 Q 566 CCB -139 582 578 574 cfl �� /�V r O CB 102 SS 580 `� 3'82 L=196.312, R=250.000 582 M - _ _ � 0 `ti CH= S2°18'47"W 191.31'T.. p CL h DELTA=44°5929" N 584 M _ �. Q - N 586 CB -109 s, 16+00CB-1o6 +00 CB 104 2 14+00 CB -107 h^�` sq" S I 6a 12+00 �, 13+00 S20° 10' 57"E _ o 42" RCP - — — _ ��� 01' S2'E U 18-1.00 \ 68 p 10+00 - -- 11--00 h� 42" RCP ; 42"RC= .32 STA: 18+32.25 (RO D 1) • 603.56' � - q`� 42" RCP _ STA 8 53 ) •• Lo 2„RC ted, saw 42” RCP i v `• — S84 CB -108 CB -114 - �- s' - _ 57 OAD CB -105. ro LOT: 15 _ ° 582 STA: 14 79.58 (R 4 _ ,• _ - - _ _ _ � - - 580 578 S�6 U 510 40,040 sq ft CB -111 ,b• , < _ _ 584 CB 110 STA: + r' 570 0.92 ac °• — 586 \ \ � 0 58 586 CB -113 CB -112 590 59 _ 4 I �� CCB -135 s' / I _ '� 572 590 I F- ----------- — ISI I . ..........f p, 590 \AI \ LOT:6 ., �'moi 56,352 sq ft al 1.29 ac c a w 580oo I 576 00 I I �C, I O LOT : 1� 1 696 I I LOT: 12 I ti 40,569 093 ac ft 50858 sq ft LC I\LOT: 11 1.17 ac I 40E LOT: 10 I 41,000 sq ft I / LOT: 9 40,987 sq ft N 0.94 ac ° 596 LOT: 8 40,974 sq ft 0.94 ac I o I 578 LOT: 7 40,961 sq ft 0.94 ac L90 40,948 40,948 sq ft 0.94 ac I CB -136 I ► I I 0.94 ac VERTICAL SCALE ( IN FEET ) 0 1 inch = 4' ft. GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. w rn O o O O O cc o m L M � m � T m x Q O OUM W z EX) � M Q O J— z Cc o -Z o O U c Q I'' W Lu W E z a� °' U � W `t � = m � -No cB 0 w z Lu Q) m O N w cj� o m cc o m In o W m � T m � z m W Q O z O � Sheet C-3.4 cj� o > cc o In o W m � T W = � z m ON Q N z + 00 O � o O Y o m I'' W O Lo D w D U � W `t � = m Q 0 w z Lu Q) m Sheet C-3.4 ED 57( 56( 55�z 3 _n+q.,,� n+nn 1+nn 9+nn ,3+nn MrsTol +nn avroTu 7+nn Ropffiff P+nn A+2,5 0+00 1+00 2+00 LOT: 20 43,137 sq ft - - - - / 0.99 ac 10' 3+00 - 574 5�2 N. / 1 OT 94 � 57� CB -130 1 LOT: 22 48,262 sq ft 1.11 ac ' \ R/W 155,451 sq ft - 3.57 ac k / 580 � 1 Co — .y 4+00 5+00 6+00 7+00 LOT: 1T 40,071 sq ft \ 0.92 ac 8+00 9+00 10, LOT: 1.6 \ / 40,240 sq ft' 0.92 ac LOT: 15 \ 40,040 sq fit, 0.92 ac 6 \LOT : 14 40,569 sq ft 0\93 ac 576 - i70 i60 i55 VERTICAL SCALE N ( IN FEET ) 1 inch = 4' ft. w GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn 0 0 �Q)Q) 0 Co a N U Q W — w 0 W z U J Q N N N Z m 00 WW M -a o � N W 7 Z) co m O U = g Z m m O W O Q O 0 O Z O Y 0 N N W o } m o O Q o 0 w � m 0 Q z co o �n t K. 30.00 CO 0 41 M + + a LOW P STA: 6+ 2.04 uj LOW P7 ELEV:5E4.02 PILI 9TA-74-32 12 m W w PVI ELEV562.84 :30.00 LVC. 91 Co K. o \ EX. G DE LT EX. GRADE CIL c+0 Lo Lo 00 g o U U> U U> EX. GRADE RT 00 LLJ W PROP. GRADE CIL o 24 RCP 24" RCP — 24" RCP 15" _ 24" RCP 24"RCP 30"RCP 36" RCP U w w w C) w w O w w o w w of 6 w w OM 00 Co w w Lo � co L w w m w w O (Z cd w w M co nj U- 0+00 1+00 2+00 LOT: 20 43,137 sq ft - - - - / 0.99 ac 10' 3+00 - 574 5�2 N. / 1 OT 94 � 57� CB -130 1 LOT: 22 48,262 sq ft 1.11 ac ' \ R/W 155,451 sq ft - 3.57 ac k / 580 � 1 Co — .y 4+00 5+00 6+00 7+00 LOT: 1T 40,071 sq ft \ 0.92 ac 8+00 9+00 10, LOT: 1.6 \ / 40,240 sq ft' 0.92 ac LOT: 15 \ 40,040 sq fit, 0.92 ac 6 \LOT : 14 40,569 sq ft 0\93 ac 576 - i70 i60 i55 VERTICAL SCALE N ( IN FEET ) 1 inch = 4' ft. w GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn 0 0 �Q)Q) 0 Co a N U Q W — w 0 W z U J Q N N N Z m 00 WW M -a o � N W 7 Z) co m O U = g Z m m O W O Q O 0 O Z O W C W J U U z z �- oQw J J � J v� � z5 w w Lu U) Q `` z LU C)Co J cMM � W 0�� � CAR�,� = SE _ 14 O lyous � 5128118 Sheet C-3.5 7 � m m O U = g Z m U O O O U o O Y 0 N N W o } m o O Q o 0 w � m 0 Q z co o �n 0�� � CAR�,� = SE _ 14 O lyous � 5128118 Sheet C-3.5 3 yyR , LOT: 16 40,240 q4 ft 0.92 ac .560 N 5908+75 9+00 58( 57( 56%' U o_ MH -101 In+nn ll+nn 11+46 90 7 \ ss co w g C 562 \ cv • + 564 CB -124 OIT- Q n -SFA 5908+75 9+00 58( 57( 56%' U o_ MH -101 In+nn ll+nn 11+46 90 6 CB -132 / DI -133 566 566 35'23" T:329.50 s6, 9+00 10+00 11+00 VOR 70 i65 S6 --------- ,--- -------- / 560 566 y , - y60 LOT: 13 40, 708 sq ft / 0.93 at, \ / LOT: 15 LOT: 14 ✓ — 570 — 40,040 sq ft 40,569 sq ft — 0.92 ac 0.93.a 572 / 574 / 576 / 578 ' STA: 18+32.25 (ROAD 1) STA: 8+53.88 (ROAD 566 Mort CB -103 6 R25' —1 CB -104 - 7 Z) co w g W U = � z m cz m O w OIT- Q 0 R59.5' d O z L�j PVI ELE :578.53 '11 W O } m O w K3 00 N 9+00 �5 10+00 '11+00 11+46 � c� CB -135 S80'58'08' m 06 K 421.69' c cry ,� 586- - _ + a a o• I LU tu �U U 15" RCP CB -105 QGQ , op W �oolo p 4'- — — — 7- — — 76 576 - 578 580 582 584 ��6 - - - - - - - - EX. GRADE CIL CB -136 42" RCP / 50' R/W N EX. GRADE RT M A/ <P, 590 ZOP. GRADE CIL 15 / Q M Lo U- w Cep Lo Lo U- w M O Lo Co LL O Co 6 CB -132 / DI -133 566 566 35'23" T:329.50 s6, 9+00 10+00 11+00 VOR 70 i65 S6 --------- ,--- -------- / 560 566 y , - y60 LOT: 13 40, 708 sq ft / 0.93 at, \ / LOT: 15 LOT: 14 ✓ — 570 — 40,040 sq ft 40,569 sq ft — 0.92 ac 0.93.a 572 / 574 / 576 / 578 ' STA: 18+32.25 (ROAD 1) STA: 8+53.88 (ROAD 566 Mort CB -103 6 R25' —1 CB -104 - I LOT': 12 566 / / N / 50,858 sq ft `t to 1.17 ac OS,� CB -106 PT: 16+84.916910 3 v VERTICAL SCALE ( IN FEET ) 1 inch = 4' ft. 0 GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn 0 0 Lo o "t L o 0 �) ODM Z m f M Co a N U Q W - w W z C0 Cm100Yu JQNN <� N Z m-00 WW o � N 7 Z) co w g W U = � z m cz m O w OIT- Q 0 R59.5' d O z L�j '11 W O } m O w N 9+00 �5 10+00 '11+00 11+46 � c� CB -135 S80'58'08' m ao 421.69' c cry ,� 586- - _ N I 15" RCP CB -105 QGQ , �— p 4'- — — — 7- — — 76 576 - 578 580 582 584 ��6 - - - - - - - - CB -136 42" RCP 50' R/W N 590 I LOT': 12 566 / / N / 50,858 sq ft `t to 1.17 ac OS,� CB -106 PT: 16+84.916910 3 v VERTICAL SCALE ( IN FEET ) 1 inch = 4' ft. 0 GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn 0 0 Lo o "t L o 0 �) ODM Z m f M Co a N U Q W - w W z C0 Cm100Yu JQNN <� N Z m-00 WW o � N Sheet C-3.6 7 Z) co w g W U = � z m cz m O w OIT- Q 0 d O z L�j Sheet C-3.6 7 � m O w g W U = � z m cz U O OIT- U O Y 0 N N '11 W O } m O w �5 z J W � m Q 0 z c Sheet C-3.6 i LINE PROPOSED EARTHEN / SSM4 SWALE WITH BERMUDA RIM 5 .15 I I GRASS OR CITY APPROVED EQUAL / 3:1 MAX SLOPE (BOTH SIDES) N / (31 SECTION A -A / NOT TO SCALE PROPOSED 6' WIDE FLAT- BOTTOM V -DITCH , Q25 = 2.56 CFS . P DEPTH OF FLOW = 0.63' ,VELOCITY = 0.56 FPS HINGED TRASH RACK P TOP OF STRUCTURE - ELEV.=549.50 c / PROPOSED RIP -RAP / Q25=2.56 CFS L = 13', W=15', 3Do=6' i FES -200 PROPOSED EMERGENCY SPILLWAY / WIDTH = 10' / \ EL=550.60- _ _ - _ _ SS O� BMP RISER SQS F� \ O� s 'OSED DRY DETENTION POND BOTTOM OF POND = 54 1. 00 ------- r PROPOSEDRIP-RAP I\\ , "Q1Q10=83.9583.95 CFS L = 26', W=30', 3Do=12' S-100 i 3 560 — GRAPHIC SCALE 0 40' 80' ( IN FEET ) --------- 1 inch = 40 ft. PRECAST STRUCTURE INSTALLED WITH "CONSEAL CS102" RUBBER SEALANT FOR WATER TIGHT JOINTS (4'x4' INSIDE DIMENSION) OR APPROVED EQUAL STEPS FOR ACCESS AND MAINTENANCE (TYP.) 6" ORIFICE OPENING INV = 541.00 6x6'x24" BALLAST PAD RISER STRUCTURE DETAIL NOT TO SCALE W C Q W J U ZIz z L oLu Qw J J mLu J_ w w uj uj 0 J Co j z rn 0 a� J � 0 o LoCn w WC's 0 o�M z m Z m Co W O 00 a I= U Q C; z w m o 0 \moo W zQ CIO W U O w o J Q N N 3 a � = N Q �zN Q Z Co Co Cu Co v Wuj O Cf) O QCU� 107tz) iZ U W o= N W C Q W J U ZIz z L oLu Qw J J mLu J_ w w uj uj 0 J Co j z 2 a� J � CoW w z W z m W W O Y a I= z w m o 0 CIO w o a W Y = N Q m Q W o Z (D Co W v O Cf) O iZ U W W J W W Q Q � Q m Y v� Q N O Z �- W C Q W J U ZIz z L oLu Qw J J mLu J_ w w uj uj 0 J Co j z 2 a� J � CoW m z W z m v J W O Y 0 I= z w m o 0 w o � W Y = N Q m Q o Z (D Co W v O Cf) CARoI f, GINEE���O`` 5128118 Sheet C-3.7 STRUCTURE TABLE STRUCTURE NAME: RIM ELEV. PIPES IN: PIPES OUT CB -102 565.15 INV IN =554.71 (26.02 LF OF 481 RCP @ 3.67% FROM CB -103) INV OUT =552.51 (154.50 LF OF 48" RCP @ 0.50% TO MH -101) CB -136 578.77 INV IN =557.34 (94.07 LF OF 36 RCP @ 0.50% FROM CB -124) INV OUT =575.23 (170.19 LF OF 15" RCP @ 4.71 % TO CB -135) CB -103 565.15 INV IN =556.16 (73.89 LF OF 42" RCP @ 3.80% FROM CB -104) INV OUT =555.66 (26.02 LF OF 48" RCP @ 3.67% TO CB -102) CB -104 569.24 INV IN =559.17 (26.00 LF OF 42" RCP @ 0.50% FROM CB -105) INV OUT =558.97 (73.89 LF OF 42" RCP @ 3.80% TO CB -103) CB -105 569.24 INV IN =565.06 (41.82 LF OF 15" RCP @ 4.71 % FROM CB -135) INV OUT =559.30 (26.00 LF OF 42 RCP @ 0.50% 0 TO CB -104) CB -141 581.09 INV IN =561.50 (104.81 LF OF 42" RCP @ 0.87% FROM CB -106) INV OUT =577.84 (26.00 LF OF 15" RCP @ 0.50% TO CB -118) CB -106 572.25 INV IN =562.61 (91.64 LF OF 42" RCP @ 2.73% FROM CB -107) INV OUT =562.41 (104.81 LF OF 42" RCP @ 0.87% TO CB -105) CB -107 574.96 INV IN =565.31 (68.73 LF OF 42" RCP @ 3.06% FROM CB -108) INV OUT =565.11 (91.64 LF OF 42" RCP @ 2.73% TO CB -106) CB -108 576.94 INV IN =567.61 (68.65 LF OF 421 RCP @ 0.500 FROM CB -109) INV OUT =567.41 (68.73 LF OF 42" RCP @ 3.06% TO CB -107) DI -133 563.98 INV IN =572.74 (26.01 LF OF 15 RCP @ 2.00% FROM CB -137) INV OUT =559.73 (46.19 LF OF 24" RCP @ 1.00% TO CB -132) CB -109 578.91 INV IN =568.16 (68.65 LF OF 42" RCP @ 0.50% FROM CB -110) INV OUT =567.96 (68.65 LF OF 42" RCP @ 0.50% TO CB -108) CB -110 580.88 INV IN =568.70 (120.00 LF OF 42" RCP @ 0.50% FROM CB -111) INV OUT =568.50 (68.65 LF OF 42" RCP @ 0.50% TO CB -109) CB -111 584.33 INV IN =579.07 (26.01 LF OF 15" RCP @ 2.00% FROM CB -138) INV OUT =569.30 (120.00 LF OF 42" RCP @ 0.50% TO CB -110) FES -100 549.66 INV IN =569.50 (240.00 LF OF 42" RCP @ 0.50% FROM CB -112) S2 CB -112 584.87 INV IN =570.90 (39.83 LF OF 42" RCP @ 0.50% FROM CB -113) INV OUT =570.70 (240.00 LF OF 42" RCP @ 0.50% TO CB -111) CB -113 583.74 INV IN =571.30 (53.45 LF OF 42" RCP @ 0.50% FROM CB -114) INV OUT =571.10 (39.83 LF OF 42" RCP @ 0.50% TO CB -112) CB -114 582.21 INV IN =571.77 (41.03 LF OF 42" RCP @ 0.50% FROM CB -115) INV OUT =571.57 (53.45 LF OF 42" RCP @ 0.50% TO CB -113) CB -115 581.19 INV IN =572.17 (64.01 LF OF 42" RCP @ 0.50% FROM CB -116) INV OUT =571.97 (41.03 LF OF 42" RCP @ 0.50% TO CB -114) CB -116 580.56 INV IN =576.58 (26.01 LF OF 15" RCP @ 2.00%0 FROM CB -139) INV OUT =572.49 (64.01 LF OF 42" RCP @ 0.50% TO CB -115) INV 1N =572.69 (106.42 LF OF 42' RCP @ 0.50/o FROM CB -117) CB -117 582.08 INV IN =573.72 (197.62 LF OF 36" RCP @ 0.801 % FROM CB -118) INV OUT =573.22 (106.42 LF OF 42" RCP @ 0.50% TO CB -116) INV IN =575.47 (22.00 LF OF 18 RCP @ 2.00% FROM DI -140) CB -118 581.09 INV IN =577.71 (26.00 LF OF 151 RCP @ 0.50% FROM CB -141) INV OUT =575.32 (197.62 LF OF 36" RCP @ 0.81 % TO CB -117) INV IN =575.82 (54.82 LF OF 30 RCP @ 1.19/0 FROM DI -119) CB -120 583.94 INV IN =578.94 (123.84 LF OF 18" RCP @ 4.403% FROM CB -121) INV OUT =578.44 (73.37 LF OF 24" RCP @ 2.00% TO DI -119) INV IN =578.94 (26.00 LF OF 18 RCP @ 0.50% FROM CB -142) CB -121 589.12 INV IN =584.87 (26.00 LF OF 151 RCP @ 1.27% FROM CB -122) INV OUT =584.42 (123.84 LF OF 18" RCP @ 4.43 % TO CB -120) INV IN =584.87 (17.90 LF OF 15 RCP @ 2.00% FROM DI -144) CB -122 589.15 INV IN =585.40 (126.54 LF OF 15 RCP @ 3.85% FROM CB -123) 0 INV OUT =585.20 (26.00 LF OF 15II RCP @ 1.27% TO CB -121) CB -123 594.02 INV OUT =590.27 (126.54 LF OF 15" RCP @ 3.85% TO CB -122) CB -124 563.76 INV IN =558.81 (26.00 LF OF 24" RCP @ 1.00% FROM CB -132) INV OUT =557.81 (94.07 LF OF 36" RCP @ 0.50% TO CB -102) INV IN =558.31 (111.28 LF OF 30 RCP @ 1.35/ FROM CB -125) CB -125 565.04 INV IN =560.31 (107.05 LF OF 24" RCP @ 1.53% FROM CB -126) INV OUT =559.81 (111.28 LF OF 30" RCP @ 1.35% TO CB -124) CB -126 566.65 INV IN =562.14 (89.38 LF OF 24" RCP @ 0.50% FROM CB -127) INV OUT =561.94 (107.05 LF OF 24" RCP @ 1.53% TO CB -125) CB -127 567.99 INV IN =562.79 (89.38 LF OF 24" RCP @ 0.50% FROM CB -128) INV OUT =562.59 (89.38 LF OF 24 RCP @ 0.50/o 0 TO CB -126) INV IN =563.54 (26.01 LF OF 15" RCP @ 2.00% FROM CB -134) CB -128 569.29 INV IN =563.44 (50.44 LF OF 24" RCP @ 0.50% FROM CB -129) INV OUT =563.24 (89.38 LF OF 24" RCP @ 0.50% TO CB -127) CB -129 570.10 INV IN =563.89 (58.21 LF OF 24" RCP @ 0.50% FROM CB -130) INV OUT =563.69 (50.44 LF OF 24" RCP @ 0.50% TO CB -128) CB -130 571.10 INV IN =564.93 (31.85 LF OF 15" RCP @ 0.50% FROM DI -131) INV OUT =564.18 (58.21 LF OF 24" RCP @ 0.50% TO CB -129) CB -132 563.76 INV IN =559.27 (46.19 LF OF 24" RCP @ 1.00% FROM DI -133) INV OUT =559.07 (26.00 LF OF 24" RCP @ 1.00% TO CB -124) CB -134 567.99 INV OUT =564.06 (26.01 LF OF 15" RCP @ 2.00% TO CB -127) 0 E STRUCTURE TABLE STRUCTURE NAME: RIM ELEV. PIPES IN: PIPES OUT CB -135 570.71 INV IN =567.22 (170.19 LF OF 15" RCP @ 4.71 % FROM CB -136) INV OUT =567.02 (41.82 LF OF 15" RCP @ 4.71 % TO CB -105) CB -136 578.77 m INV OUT =575.23 (170.19 LF OF 15" RCP @ 4.71 % TO CB -135) CB -137 576.94 INV OUT =573.26 (26.01 LF OF 15" RCP @ 2.00% TO CB -108) CB -138 584.33 M C_ INV OUT =579.59 (26.01 LF OF 15" RCP @ 2.00% TO CB -111) CB -139 580.56 c INV OUT =577.10 (26.01 LF OF 15" RCP @ 2.00% TO CB -116) CB -141 581.09 Lu INV OUT =577.84 (26.00 LF OF 15" RCP @ 0.50% TO CB -118) CB -142 583.94 INV IN =579.27 (19.72 LF OF 18" RCP @ 0.50% FROM DI -143) INV OUT =579.07 (26.00 LF OF 18" RCP @ 0.50% TO CB -120) DI -119 582.82 INV IN =576.97 (73.37 LF OF 24" RCP @ 2.00% FROM CB -120) INV OUT =576.47 (54.82 LF OF 30" RCP @ 1.19% TO CB -118) DI -131 568.59 INV OUT =565.09 (31.85 LF OF 15" RCP @ 0.50% TO CB -130) DI -133 563.98 00 m 00 t4 INV OUT =559.73 (46.19 LF OF 24" RCP @ 1.00% TO CB -132) DI -140 579.41 INV OUT =575.91 (22.00 LF OF 18" RCP @ 2.00% TO CB -117) DI -143 582.87 Y INV OUT =579.37 (19.72 LF OF 18" RCP @ 0.50% TO CB -142) DI -144 588.73 o� N INV OUT =585.23 (17.90 LF OF 15" RCP @ 2.00% TO CB -121) FES -100 549.66 INV IN =545.00 (183.46 LF OF 48" RCP @ 3.56% FROM MH -101) S2 MH -101 559.24 INV IN =551.74 (154.50 LF OF 48" RCP @ 0.50% FROM CB -102) INV OUT =551.54 (183.46 LF OF 48" RCP @ 3.56% TO FES -100) w rn 0 Z) W J Q) oM co m m Lo 0 ur) co WV 0 o�0) m Z m � M -� O z M _ M C_ z Q U Q c Lu Y - Lu w N Z z �, ��� a� Q N w Q� U ��N o LL- Z N Z 00 m 00 t4 WW > z W M a Y � m o� N w ct Z) W J m co m m Q m m U U O 0 0 z Q J W � CL z W J U ULu J J m J ui W w z U) `` zuj C) Qco �z OD J C) J_ m ui ct W J m co m Q w m U O rW V Q o z _ Y N c m Q w O o Z W O Y � m Q w Z S2 W o Sheet C-3.8 NUMBER AND SIZE OF DOMESTIC AND IRRIGATION WATER METERS: 3" DOMESTIC METERS = 28 3n In 11 ATI k AArrr n _ nn 4 CONSTRUCTION SCHEDULE START: AUGUST 2018 END: AUGUST 2019 *ASSUMES HALF INCH WATERINGS WEEKLY ON 5,000 SQ. FT. OF LAWN 5,000 SQ FT * 28 LOTS = 140,000 SQ FT 2 " = 0.041666 FT. A _ /1/1/1 n - - A nAAI_1 rT _ L rl nn -1 1 rT 1 GALLON = 7.48052 CU. FT. vv 5,832 CU. FT = 43,629 GALLON PER WEEK 43,629 GALLONS / 7 DAYS = 6,232 GALLONS PER DAY WATER FLOW ASSUMES 400 GALLONS PER DAY SEWER FLOW ASSUMES 285 GALLONS PER DAY 28 LOTS - SINGLE FAMILY RESIDENTIAL WATER = 28 LOTS x 400 GALLONS PER DAY = 11,200 GPD SEWER = 28 LOTS x 285 GALLONS PER DAY = 7,980 GPD (DOMESTIC SEWAGE) MATERIAL SUMMARY WATER LF AMOUNT 6" DIP 274 7,980 GALLONS PER DAY 6" PVC 2,463 PLAT CAB. N, FILE 524 2" PVC 264 ZONE: R-40 SERVICES 28 FIRE HYDRANTS 3 BK. CS13-496 c SEWER LF AMOUNT 8" DIP 60 z 8" SDR -26 815 ` 8" SDR -35 1,866 MANHOLES 16 SERVICES O = 28 DAVID E. BALLENGER BK. 602-107 TAX PIN: 06-030-002A / NOW OR FORMERLY ZONE: R-40 \ USE: VACANT \ 1 EX. MH ID: 1647 i MICHAEL DAVIS \•\ TAX PIN: 06-030-002B NOW OR FORMERLY ZONE: R-40 USE: VACANT ESTIMATED CONSUMPTIONS JACK CASE 11,200 GALLONS PER DAY BK. 7071-403 6,232 GALLONS PER DAY TAX PIN: 06-030-0148 7,980 GALLONS PER DAY TRACT 3 z m � PLAT CAB. N, FILE 524 / \ NOW OR FORMERLY ZONE: R-40 ZONE: R-40 USE: VACANT CL USE: RESIDENTIAL BK. CS13-496 ESTIMATED CONSUMPTIONS WATER 11,200 GALLONS PER DAY IRRIGATION 6,232 GALLONS PER DAY SEWER 7,980 GALLONS PER DAY BLAIR BURKE BK. 7100-160 TAX PIN: 06-030-014A TRACT 2 PLAT CAB. N, FILE 524 NOW OR FORMERLY ZONE: R-40 USE: VACANT CHARLES B. BAUCOM TAX PIN: 06-027-048 TRACT 5 PLAT CAB. K, FILE 722 NOW OR FORMERLY ZONE: R-40 USE RESIDENTIAL WESLEY OAKS HOA BK. 4384-523 TAX PIN: 06-048-323 ZONE:R-40 ROY & MELISSA HALL rn 0 Z) zm 0 Lo oM 0 Cr USE: COMMON AREA BK 4461-613 TAX PIN: 06-027-042 NOW OR FORMERLY / MARLENE LYONS z m � / ZONE: R-40 TRUSTEE CL USE: RESIDENTIAL BK. CS13-496 c N ` TAX PIN: 06-027-042A NOW OR FORMERLY E 0 z a) Lu �-j (or) a) ` ZONE: R-40 Lu CH USE: RESIDENTIAL RICHARD KAPITAN AAlaw OO D BK. 6012-624 TAX PIN: 06-027-004B _ ROAD ` RICHARD KAPITAN NOW OR FORMERLY EX. FH w- _ \ ~� p�B��C TAX PIN: 06-027-004B BK 6012-624 ZONE:R-40 NOW OR FORMERLY USE: RESIDENTIAL BENTON EDWARDS ZONE:R-40 _ BK. 734-397 I'i'_ _ USE: RESIDENTIAL TRACT 1 ` w� _ PLAT CAB. D, FILE 583 BENTON EDWARDS w_ TAX PIN: 06-027-044 BK. 920-782 LANDON MUNDY NOW OR FORMERLY TAX PIN: 06-027-043 wo _ BK 6900-413 ZONE:R-40 NOW OR FORMERLY _ _ ® ------- TRACT 2 USE RESIDENTIAL � � _ -w- _ PLAT CAB. D, FILE 583 EX. 8" PVC WM _ w TAX PIN: 06-027-045 NOW OR FORMERLY _ ZONEDEN IL USE RESIDENTIAL LOT: 5 LOT: 1 OPEN SPACE: 120 / IL59,984 sq ft I I I I 43,441 sq ft 9096 act l 1.38 ac 1.00 ac / / JDITH B. ZIMMER LOT:4 LOT:3 LOT:2 / X PIN: 06-027-049A LOT: 6 43,306 sq ft 40,422 s ft 41,374 sq ft BK. 1747-130TRACT 56,352 sq ft 0.99 ac 0.93 a� l 'ART OF TRACT 6 0.95 ac / aT CAB. K, FILE 722 1.29 ac >W OR FORMERLY \ I �rL / ZONE: R-40 I I I G' 6„WM SE RESIDENTIAL / JOHN H. HUCKERT, JR. \ / BK. 6354, PG. 141 \ LOT: 7 `n' P� I OPEN SPACE : 107 TAX PIN: 06 027-006 ft \ ww\\ �1" NOW OR FORMERLY 40,948 s \ q \ `JSoA - \ 8,546 sq ft ZONE:R-40 0.94 a \I! 1. r - � I 0.20 ac USE RESIDENTIAL �i Jr l V \ - PROP. MH - 10 LOT: 8 1, 8 5,04 sq. ft. PROP. MH - 8 FFi I / - \ 40,961 sq ft 42. MIN. FFE: 580.5' MIN. FFE: 58 .0' MIN. FFE: 581.0' \ 0.94 ac 6 ac PROP. MH - 7 PROP. MH - 9 LOT: 28 / I 43.00 ac ft 1 / 1.00 \ MIN. FFE: 40,974 aq f t \ \ G,�C s �� LOT: 24 I LOT: 25LOT: I l \ <41,998 sq ft LOT: 27 0.94 / V 0.96 ac LOT : 26 40,130 sq ft / C, 41,071 s q ft 41,930 sq ft 0.92 ac / N 0 96 ac JUNE MOORE \� LOT: 10 \ \ \ 40,987 sq ft \ 0.94 ac \ \ LOT: 11 \ ,A \ 4 1, 000 sq ft 0.94 ac �\ BOG LOT: 12 50,858 sq ft Gj / ,A 1.17 ac \ �� I - LOT: 13 / 40,708 sq ft 2"WM - 0.993 ac/ / LOT: 14 / 40,569 sq ft / LOT: 15 40,040 sq ft 0.92 ac /. 0.94 ac I / DOROTHY MOREE BK. 6403, PG. 115 MIN. FFE: 577.8' \ I ( I l PLAT D-520 TAX PIN: 06-027-010 ` I NOW OR FORMERLY LOT: 23 ZONE:R-40 PROP. MH - 6 40,248 sq ft \ USE RESIDENTIAL 0.92 ac MIN. FFE: 577.5' R/W / 55,451 sq ft �\ �- 3.57 ac LOT : 22 \ \ 1.11 ac ` OPEN SPACE \ I`l�1 vLOT : 16 l PROP. MH - 14 MIN. FFE: 562.0' 391,321 sq ft Cj \ 8.98 ac 1 40,240 sq ft -,\ PROP MH 2 0 92 ac \ L 45, 1 LOT: 17 I 40,071 sq ft I 0.92 ac LOT: 18 40,073 sq ft I _ / 0.92 ac EX. MH ID: 1646 EX. 18 _EX.' S.S. 18 \ �� EX. MH ID:1645 EX. MH ID:1648 z7ORK OF ✓E MILE CREEK LOVELL FAMILY LIMITED PARTNERSHIP BK. 1488, PG. 821 TAX PIN: 06-027-007 NOW OR FORMERLY UNINCORPORATED UNION COUNTY ZONE: R-40 USE: VACANT � I LOVELL FAMILY / LIMITED PARTNERSHIP BK. 1488, PG. 821 �6"WM TAX PIN: 06-027-007 NOW OR FORMERLY LOT: 21 UNINCORPORATED 40,291 sq ft / UNION COUNTY 0.92 ac / 0 MARK J. ROSENBLUM / PROP. MH - 16 & KATE K. ROSENBLUM I / BK. 550, PG. 851 / TAX PIN: 06-027-005A / NOW OR FORMERLY ZONE: R-40 / \ USE RESIDENTIAL / LOT: 20 \\ / MH - 15 43,137 sq ft 0.99 ac \ \ OT: 19 \ \ I 589 sq ft \ \ l .05 ac A l EX 1 " S. S. � �I _ --ss- / EX. MH ID.- 1650 / I � / I I � I GROHI SCA\ I / 0 100 ( IN FEET ) 1 inch = loo ft. Lu rn 0 Z) zm 0 Lo oM 0 Cr Cn ur) co 0 z m � m � M U CL O 1 � U Q c N J W Cf) E 0 z a) Lu �-j (or) a) �() �U-N4 Lu O Z N O = 7�p 00 = 00 c4 WW m Q c� a � m �n O N Lu X Z) zm m Cr Cn W U z m � m U D O Y Z __j W C Q W J U u Zcl-z z LuoLu Qw J J mLIJ J uj w w z (f) Q Q� `` z uj ouj Q�z J J m CAR ,O.a��FEsslpN9O�f , IYOU5 � 5/28/18 Sheet C-4.0 X zm Cr J C W U z m � - Y o N J J o w 0 Lu O W Y O = m Q w 00 D m �n CAR ,O.a��FEsslpN9O�f , IYOU5 � 5/28/18 Sheet C-4.0 3 a w rn O LL O O O L M cc w Z WV � O o��; m z m � M cl� N C r_ z Q U C Q Lu W o °' CL z a� Lu Q) Q Uj z vJ W `t � m -Nm m m 0 w z Lu Q) m (n M � o = N 58 80 a — 0 a o 0 =�Mt\ Lo � C cc + p Co z 0 o / RCP 42" RCP o15" 2 o Ci Lo - gg 42"RCP 42" RC 42" RCP 71'— — a�MZ � ELs �> °�co 57 ML CoCoN 2 / -. 70 / ,L6 LLo CL a M ? Z p PROP. / 321.19' of IQ- ? > > > —GRADE coN 000/ m N o = o 5-1 GRADE 20 ? > o a Co z z — 4T01- @ 2.0 / 42 RGP 116.63' of 8, S.S. M / g / 42" RCP O 20' 000/6 _ / as N N o o M Mo N a N 6 1'of8„SS•@3 42" RCP 42” RC P EX. GRADE n g0 56 � Co Q a N M Z Z pp 60 a 36" RCP M a CO z ri If o a u Z p ? > > 48" RCP OUTSIDE DROP ac) z z MANHOLE INV. IN:555.20 O OU Lo W a r) v a? / 0 to _g O+ Z Cl a' R uj a) 55 100 YEAR FLOOD ELEV. 549.4± 50 / y00 2g SEWER LATERALS FOR LOTS 9-12 TO BE INSTALLED ABOVE STORM DRAINAGE PIPES VERTICAL SCALE PRO OSED SD 26 N 87.57 of 8" S.S. @ 0• 60% PRO OSED DI 1 ( IN FEET ) inch 4' ft. = 54 ° 40 @2.So% 15118'of8.,S.S. 53 36 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 11+50 \ LOT: 12 \ \ 50,858 sq ft DETENTION Q 1.17 ac I I I LOT: 11 POND 41,000 sq ft 0.94 ac ' I LOT: 10 40,987 ft I \ \ 0.94a� / a / ' I LOT: 9 40,974 sq ft �f MgTC 2p' LOT: 150.94 40,040 sq ft I I ac ' 0.92 ac 2" WC YO / I F C-4 \ I cs� 3 3' MIN. COVE � / ' I O \ \ PROP. MH - 4 PSDE & S.S. r , O r p JOINT ESMT. \ 6"GV « ' o� "X2" REDUCER 6"X6" TEE PROP. MH - 2\�\ 2 \ l '• V WMX-ING ABOVE STORM O � A2•� ' CA 55@ ¢22° BOTTOM 6" WM:562.0 cp ', VFSS Sg / TOP 42RCP:556.9 663 5 \ o w " Y S�q (SO IRRIGATION & DOMESTIC METER \ o\0 R� `ROP. FH Sg p�s2F 04 4—[ Rco 20' -DIP Q \ "G _—CP _ DUAL (TYP.) I ' ' y� 4" SEWER ' \ 33 g9 \ / / o I° / � p k� FROM E E TO GV WM` ABOVE STORM G:569.8 PROP. MH - 3 48'RCp BOTTOM 6" WM:566.1 42„RCP 900 LATERAL (TYP.) 42"RCP U 321 99'0 SS • ��� yo Z PROP. MH - 1 6"WM / TOP 42” RCP:562.8 �° 1.14° f0 / • \ \ S @ / 1a 5 / �y1 • 036 j LOT : 16 O PROP. MH - 5 3 OFF BOC , 'MIN. COVER MqT 2 Cy<�N _ S20 1057E 42'R 6" GV 42 "RCP 11,00 ' � \ \ / 40,240 sq ft 0.92 ac .` � � F SNFFT 6"WM \ . C-4 4 ` 3' OFF BOC 3' MIN. COVER 6"X6" ( FROM GV TEE '> _ 2'`00 EX. MH DA645 \ \ Q� I �' PROP. FH (20) 6" RJP FROM TEE TO GV a - (3 PROP. MH - 6 \ 24 CP I I OPEN SPACE j a• C) , R/W MIN. FFE: 577.5' 15 sq ft 2 I \ \ \ \ 6„ V 3' OFF I 3' MIN. act B03C5 COVER Z \ \ \ PROP. MH- 12 w I I LOT: 22 48,262 sq ft 1.11 ac h _ GRAPHIC SCALE MIN. FFE: 562.0' \ 0 40' 80' IN FEET ) l I I 1 1 inch = 40 ft. w rn O LL O O O L M cc w Z WV � O o��; m z m � M cl� N C r_ z Q U C Q Lu W o °' CL z a� Lu Q) Q Uj z vJ W `t � m -Nm m m 0 w z Lu Q) m (n M � o = N w LL Co cc w Z O w U m m cl� N C z Q Y 0 z J W CL z W -� U U Z Cl - CL CC Lu Lu l-oQw Lu w w z cn Q `` z U uj Q) C)uj co QDo J m uj> LL Go U cc w Z O w U m cl� N C z Q Y N N m 0 o w 0 CL Q Uj z vJ W `t O = m Q 0 w z Lu Q) m (n CARO _ C-4 149 9 = i O FNGINEE�,�\�O ` 5128/18 Sheet C-4. 1 3 a E m a T 3 o 3 E 11+00 590-- 58( 57( 56,1 SS -A PROFILE 19+nn 1q+nn is+nn iq+nn 1R+nn 1 7+nn 1R+nn 10+nn SEWER LATERALS FOR LOTS 1-8 TO BE INSTALLED ABOVE STORM DRAINAGE PIPES LOT' 8 40, 961 sq ft 0.94 ac \ LOT:7 40,948 sq ft 0.94 ac N GP JE- RIVv) kuv 4 0o �3 S@Oy0% s2 ' SZoo�o y�"E A2" RC ono i " 6 WM / MIN. FFE: 577. 3' OFF BOC X MIN. COVER PROP. MH - 6 / Z m z 77.5' m OT: 22 262 sq ft 1.11 ac LOT: 23 40,248 sq ft 0.92 ac I LOT : 6 56,352 sq ft 1.29 ac PROP. MH -7 42" RCP 4 C 42" RCP 120.26' SS @ 0.50% 5+00 S5°13'59"E MIN. FFE: 578.5' 1 LOT: 24 1 41,998 sq ft 0.96 ac 1 1 1 1 1 PROP. MH -8 / \76x00 �\ o Sin WN. FFE: 580.5' / / LOT : 25 41,071 sq ft / 0.94 ac / / / / LOT -4 / 43,306 sq ft 0.99 ac IRRIGATION & DOMESTIC / DUAL METER (TYP.) / V 4" SEWER 1>x LATERAL (TYP.) 00 MIN. FFE: 581.0' PROP. FH / / LOT:26 41,930 sq ft / 0.96 ac / / LOT:27 40,130 sq ft 0.92 ac / LOT : 3 40,422 sq ft / 0.93 ac / / / / V / / '.MH -91 7q8 pq ' S2j¢ S��Spo •� 425,%2 FFE: 581.0' LOT:2 41,374 sq ft 0.95 ac 30" RCP !t- INA -70 i65 LEGEND: VERTICAL PROPOSED SDR 35 SCALE PROPOSED SDR 26 PROPOSED DIP ( IN FEET ) 1 inch = 4' ft. 0 \ EXISTING 8" \ \ �� sQ��00, \ / \ WATERMAIN 'vvJ LOT : 1 TAPPING SLEEVE 43,441 sq ft \/ & VALVE, \ �� 1.00 ac \ \ W/ JUMPER / CONNECTION \ / \ `ETAIL 25) \ 400, / / / / OPEN SPACE: 120 (54) 6 RJDIP z / 9,596 sq ft FROM TAP TO GV 0.22 ac m / 6"GV 4 20' -DIP PROP. MH - 10 n 6"WM 3' OFF BOC n � n X MIN. COV WM X-ING BELOW STORM / G:584.5 \ BOTT. 18" RCP:579.1 / \TOP 6"WM: 578.0 !� (SEE DETAIL 31) 5 v - � I / 1711 OPEN SPACE: 107 8,546 sq ft 0.20 ac LOT : 28 43,358 sq ft 1.00 ac / / / / GRAPHIC SCALE 0 40' 80' / ( IN FEET ) 1 inch = 4o ft. Ho -d -HOd rn 0 vJ o � � N M Lo g+Lo Imo- to o aQj0�Z Z 0 Lo oM 0 m z WV ur) co 0 o�0) m O Z m � M -� u a U Q •� rn 0 o z U uj Co � } a� U01) N ami RN �() O a Q o 2O u- z Z N a NCo� = n1 Co 1. N � a�-�z o k, LLQ W EX. GRADE m Q Q 3� M a w to a^��Z E2? ? D m �n o N °pN p �+� Q: z o a _ _ Lo c0 a��0 O Q > CL Co � - PROP. GRADE 36" RCP 15" RCP 42" RCP 42" RCP 42" RCP - 42" RCP 42" RCP- - - 0 148.04' of 8" S.S 5()Ol. 20' 42" RCP - 40. 257.27' of 8" S.S. @ 0.50% - 42" RCP -_wzz- - 120.26' of 8" S.S. @ 0.50%- ==P: 321.19' of 8" S.S. @ 0.50% MAX. DEPTH:13.9' - it+nn 12+nn ,3+nn 14+nn iS+nn 1(3+nn 17+nn 1R+nn i.q+nn 2n+nr, SEWER LATERALS FOR LOTS 1-8 TO BE INSTALLED ABOVE STORM DRAINAGE PIPES LOT' 8 40, 961 sq ft 0.94 ac \ LOT:7 40,948 sq ft 0.94 ac N GP JE- RIVv) kuv 4 0o �3 S@Oy0% s2 ' SZoo�o y�"E A2" RC ono i " 6 WM / MIN. FFE: 577. 3' OFF BOC X MIN. COVER PROP. MH - 6 / Z m z 77.5' m OT: 22 262 sq ft 1.11 ac LOT: 23 40,248 sq ft 0.92 ac I LOT : 6 56,352 sq ft 1.29 ac PROP. MH -7 42" RCP 4 C 42" RCP 120.26' SS @ 0.50% 5+00 S5°13'59"E MIN. FFE: 578.5' 1 LOT: 24 1 41,998 sq ft 0.96 ac 1 1 1 1 1 PROP. MH -8 / \76x00 �\ o Sin WN. FFE: 580.5' / / LOT : 25 41,071 sq ft / 0.94 ac / / / / LOT -4 / 43,306 sq ft 0.99 ac IRRIGATION & DOMESTIC / DUAL METER (TYP.) / V 4" SEWER 1>x LATERAL (TYP.) 00 MIN. FFE: 581.0' PROP. FH / / LOT:26 41,930 sq ft / 0.96 ac / / LOT:27 40,130 sq ft 0.92 ac / LOT : 3 40,422 sq ft / 0.93 ac / / / / V / / '.MH -91 7q8 pq ' S2j¢ S��Spo •� 425,%2 FFE: 581.0' LOT:2 41,374 sq ft 0.95 ac 30" RCP !t- INA -70 i65 LEGEND: VERTICAL PROPOSED SDR 35 SCALE PROPOSED SDR 26 PROPOSED DIP ( IN FEET ) 1 inch = 4' ft. 0 \ EXISTING 8" \ \ �� sQ��00, \ / \ WATERMAIN 'vvJ LOT : 1 TAPPING SLEEVE 43,441 sq ft \/ & VALVE, \ �� 1.00 ac \ \ W/ JUMPER / CONNECTION \ / \ `ETAIL 25) \ 400, / / / / OPEN SPACE: 120 (54) 6 RJDIP z / 9,596 sq ft FROM TAP TO GV 0.22 ac m / 6"GV 4 20' -DIP PROP. MH - 10 n 6"WM 3' OFF BOC n � n X MIN. COV WM X-ING BELOW STORM / G:584.5 \ BOTT. 18" RCP:579.1 / \TOP 6"WM: 578.0 !� (SEE DETAIL 31) 5 v - � I / 1711 OPEN SPACE: 107 8,546 sq ft 0.20 ac LOT : 28 43,358 sq ft 1.00 ac / / / / GRAPHIC SCALE 0 40' 80' / ( IN FEET ) 1 inch = 4o ft. Ho -d -HOd Lu rn 0 vJ L 0 Lo oM 0 m z WV ur) co 0 o�0) m O Z m � M -� u a U Q � 0 o z U uj Co E } a� U01) N ami RN �() Q N U - Q o Lr-� u- z Z N W Y LLQ W m Q Q 3� M a w � D m �n o N Lu vJ L m L m z 0 Z = U m O uj m u a 0 � 0 o z Y uj vJ L m L m z 0 Z = U m O uj � o Q N Y N + z } N- � z � w Q o 0 Qz W Y O = m Q w D m �n S _ - : 9 ,FiyGINEE���O` ` 5/28/18 Sheet C-4.2 3 v1H 1549.46 �j C �x 0 \ 5 -0+25 0+00 570- 56( 55( 1+nn 9+nn +nn 3+50 70 540— _0+25 0+00 Z m Cn m m y 0 0 `o w N � PROP. MH - 2 PROP. MH - 1 U 10' 30' vW19 DETENTION POND 17 on 318.00' SS @ 2.38% I I PSDE & S. S. } JOINT ESMT. LOT: 16 � LOT: 15 40,240 sq ft I 40,040 sq ft O 0.92 ac , 1 0.92 ac FFE:562.0' I � / CL U 1' MIA LOT: 14 40,569 sq ft 0.93 ac Kullt i50 40 3+50 PROP. MH- 11 4" SEWER LATERAL (TYP.) LOT: 13 40,708 sq ft 0.93 ac I PROP. FH 6"Gt'& 6'X2' REDUC R 2„WM IRRIGATION & DOMESTIC 3' OFF BOC DUAL METER (TYP.) 6'X6” TEE 3' MIN. COVE . V ° 2"GV & _ EACH IN VALVE BOXES p p . • C• .p 'p . F p P = 36" RCP CL H - 3 6+00 ROP. MH - 4 TRAVERS COURT 0+(CD (50' R/W) y �+0 — ,_ — _ _.-,, — —• 15 RCP P p pr Pr r• p 24 RCP Ge 42" u CP J W M LEGEND: VERTICAL PROPOSED SDR 35 1 SCALE PROPOSED SDR 26 PROPOSED DIP ( IN FEET ) 1 inch = 4' ft. 0 0 0 O � � T 518" EIR E GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. rn 0 0 oM Li 0 Lo co ro � 0 j z O Q m � M a 0 d p N Q 1 U Q c W — � W w zm Co N z �� CIO Q CIO 14 W 4� QUA LL- z Z N z m 00 c4 W uj Q C� M a r1 v J W Y � o N m Q w z m CLLo s CL Co Lo N = O I p N +(oto, a O N z? O EX. GRADE i PROP. GRADE 48" RCP 1800' of 8.1 S. S @ 2.38% 31800, 540— _0+25 0+00 Z m Cn m m y 0 0 `o w N � PROP. MH - 2 PROP. MH - 1 U 10' 30' vW19 DETENTION POND 17 on 318.00' SS @ 2.38% I I PSDE & S. S. } JOINT ESMT. LOT: 16 � LOT: 15 40,240 sq ft I 40,040 sq ft O 0.92 ac , 1 0.92 ac FFE:562.0' I � / CL U 1' MIA LOT: 14 40,569 sq ft 0.93 ac Kullt i50 40 3+50 PROP. MH- 11 4" SEWER LATERAL (TYP.) LOT: 13 40,708 sq ft 0.93 ac I PROP. FH 6"Gt'& 6'X2' REDUC R 2„WM IRRIGATION & DOMESTIC 3' OFF BOC DUAL METER (TYP.) 6'X6” TEE 3' MIN. COVE . V ° 2"GV & _ EACH IN VALVE BOXES p p . • C• .p 'p . F p P = 36" RCP CL H - 3 6+00 ROP. MH - 4 TRAVERS COURT 0+(CD (50' R/W) y �+0 — ,_ — _ _.-,, — —• 15 RCP P p pr Pr r• p 24 RCP Ge 42" u CP J W M LEGEND: VERTICAL PROPOSED SDR 35 1 SCALE PROPOSED SDR 26 PROPOSED DIP ( IN FEET ) 1 inch = 4' ft. 0 0 0 O � � T 518" EIR E GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. Lu rn 0 0 oM Li 0 Lo co ro � 0 j z O Q m � M a 0 d p N Q 1 U Q c W — � W w zm Co N z �� CIO Q CIO 14 W 4� QUA LL- z Z N z m 00 c4 W uj Q C� M a r1 v J W Y � o N Lu m W ro � m j z O Q w U a 0 d z Q 1 Sheet C-4.3 m W ro � j z O Q w U m � W Q 1 � zJ O N Y Co N m Q W z r1 v J W Y OO 2 m Q w z m Sheet C-4.3 -n+q,q n+nn 57( 56( 1+nn 9+nn q+nn a+nn a+R� 55 -0+25 0+00 / f oe \\ '� HUGE 1� 6 63 <1 � )rV 9 0152 C/S�\v�l / / N ZJ / /PROP. MH - 3 \ Q a'\ cn, mos n n� IQ, s MIN. FFE: 562.0' LV 1 10 40,240 sq ft 0.92 ac LOT: 17 40,071 sq ft 0.92 ac PROP. MH - 5 PROP. \ PROP; MH - 13 9j90 RcA 357,�� FAII1/J OPEN SPACE 71,807 sq ft 1.65 ac PROP. MH - 14 i 9a 35 � 48.84 S16°134" 24" R RCP LOT: 18 40,073 sq ft 0.92 ac J+UU h� 4+00 4+85 50 LOT : 22 rn 0 48,262 sq ft 1.11 ac — — WM X-ING ABOVE STORM � — G:571.7 0 BOTTOM 6" WM:566.4 — m � M TOP 15" RCP:568.2 0 o _ co Lf, +T acetm av~iE2z J— o CL z Y U Q Co L o� Cl) a 'Lo EX. GRADE C.L ��"'� o to o +� Lo =pjo�� C (N Lo to Lo dNtF O QLU)nom?? 0 �q-z» \ 0 Loo Cc �+ aCo to zo PROP. GRADE z � �W w m as M W o II Mo�N 16 �o0 +Lo a `oo_Z p a�cnE2?Z Z Z m ��� �I N 3 4� �U� LL- Z N z m 00 c4 LULU Ci vJ W Y = M a � 15" RCP m Q O N w CIO Q m n - 24" RCP 24" RCP ^ 24" RCP — 24" RCP _ 101.97' of 8" PVC @ 0.60% 98.35' of 8" PVC @ 0.83% — 30" RCP 36" RCP — @ 3.00 0 4g 84' of $ PVC o PVC @ 1.50% 97.90' f 8' 105.65' of 8" PVC @ 0.60% 55 -0+25 0+00 / f oe \\ '� HUGE 1� 6 63 <1 � )rV 9 0152 C/S�\v�l / / N ZJ / /PROP. MH - 3 \ Q a'\ cn, mos n n� IQ, s MIN. FFE: 562.0' LV 1 10 40,240 sq ft 0.92 ac LOT: 17 40,071 sq ft 0.92 ac PROP. MH - 5 PROP. \ PROP; MH - 13 9j90 RcA 357,�� FAII1/J OPEN SPACE 71,807 sq ft 1.65 ac PROP. MH - 14 i 9a 35 � 48.84 S16°134" 24" R RCP LOT: 18 40,073 sq ft 0.92 ac J+UU h� 4+00 4+85 50 LOT : 22 rn 0 48,262 sq ft 1.11 ac — — WM X-ING ABOVE STORM � — G:571.7 0 BOTTOM 6" WM:566.4 — m � M TOP 15" RCP:568.2 0 15" RCP J— o CL z Y U Q W z � �W w m Z Z m ��� �I N 3 4� �U� LL- Z N IRRIGATION & DOMESTIC LOT: 21 DUAL METER (TYP.) 40,291 sq ft I0.92 ac �I N 6"WM 3' OFF BOC X MIN. COVER 4" SEWER LATERAL (TYP.) \ < \ \ LOT : 20 43,137 sq ft \ 0.99 ac LOT: 19 45,589 sq ft \ \ 1.05 ac \ \ LEGEND: PROPOSED SDR 35 PROPOSED SDR 26 PROPOSED DIP VERTICAL SCALE N ( IN FEET ) 1 inch = 4' ft. 0 GRAPHIC SCALE 0 40' 80' ( IN FEET ) 1 inch = 40 ft. LU rn 0 0 oM Cr j � O Q Lo 0 uo co z m � 0 m � M a 0 1 J— o CL z Y U Q W z � �W w m Z Z m ��� 1501) N 3 4� �U� LL- Z N z m 00 c4 LULU Ci vJ W Y = M a � � m Q O N w LU IM W Cr j � O Q w U z m � m a 0 1 0 W z Y J W CL z W -j U U�1�1- LU Q z z L ow J J J uj Wiz; w w LU U) Q `` z U uj Q�z co C) J m LU IM W Cr j � O Q w U z m � CL LU 1 W O Y N z � } m w CL r^ vJ U Z Ci vJ W Y = � m Q w CIO Q m n \\,1111II 111111, CAROM% IoUs\\\\ I" Ill I'll l 10 5128118 Sheet C-4.4 3 v 0 - 1 -0 C I--1 ' z m000 r 0-1�O mz =� =-nDDm = OO O ZI I0r-1 nDy> cn I: O O ' z m C z O r - Z C-) o =mcn m M > c n D � v D FH � m N G) 1.4 T Z SHEET 1 OF 2 840.02 BACK OF CURB X v v v A,.. t m PLAN X Y SECTION Y -Y RISER HT. VARIES v Pp WHERE 30" TO 36" PIPE IS USED RISER HT. VARIES - - - - 6 WHERE 42" TO 54" PIPE IS USED DETAIL SHOWING METHOD OF RISER CONSTRUCTION GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 8'-0' TO 16'-0' IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. SECTION X -X T / SECTION J -J SEE NOTE WHERE 30" TO 36" PIPE IS USED :ol B p ':1 of a I •' .I PLAN STEPS - STD. NO. 840.66 Z O 0 H- a Q 2E,=(=,sU LL. JdHZ O O O = =Z Uj Q U O cf) LL 0 J 00U)Q z a: > � CL Q D _ 0 Z U- v to � m H cr_ = a 0 ~v O � _ cr Q W = H 0 W - CC N c T H Z J O C7 V W HEET 1 OF 2 840.02 v m H z >"0 m �-I A z 00 Q Q zm=(j D' E'l o. B PIPE D D' 611-G o. 6" oo�xz WQaLL a 0 O CD Z�OHT1 D c �L cf) J y D WATER FLOW - SAG �- WATER FLOW F T r T 1 9%g" LL 0 z cr O FA °C Cn '-' v 3'-8" �> Fy O z SECTION M -M g 1L2// I 1,r 1 LLJ WHERE 42" TO 54" PIPE IS USED 0.020 0.032 ----------------------- 8rr SECTION B -B 2'-0" 1 0.362 1 " 21/4 " 0.659 m �0 z -� WATER FLOW -�- SAG -�- WATER FLOW -■- ''1 A r 2'-0" SECTION A-Acn LL = DD °1 TYPE "F" TYPE "E" TYPE "G" TYPE - E z x Z Q zP 24" 3'-8" 0 a W-6" RAISED FLOW ARROW z y RAISED FLOW ARROW 2�" 2�„ /8 HIGH �.1 o co; o N vv PLAN Z O 0 H- a Q 2E,=(=,sU LL. JdHZ O O O = =Z Uj Q U O cf) LL 0 J 00U)Q z a: > � CL Q D _ 0 Z U- v to � m H cr_ = a 0 ~v O � _ cr Q W = H 0 W - CC N c T H Z J O C7 V W HEET 1 OF 2 840.02 v m H z >"0 DETAIL SHOWING TYPES OF GRATES USE TO WATER FLOW. 2' 113/ 2 II 1%2"� z 00 Q Q zm=(j ACCORDING WIDTH B PIPE D "m --I O0mC7� __ mo o mo „ rr „ „ „ „ TYPE G TYPE E TYPE F I A A 1 �� I 9%g oo�xz WQaLL a 0 O CD Z�OHT1 B c �L cf) J y D WATER FLOW - SAG �- WATER FLOW F T r T 1 9%g" LL 0 z cr O FA °C Cn '-' 12" 3'-8" �> Fy O z 0.362 g 1L2// I 1,r 1 LLJ 0.958 0.020 0.032 ----------------------- 8rr SECTION B -B 2'-0" ,T 0 0.362 1 " 21/4 " 0.659 m �0 z -� WATER FLOW -�- SAG -�- WATER FLOW -■- 0.036 0 " C 0 o O Q r 2'-0" SECTION A-Acn LL = DD rn m cn z V = TYPE "F" TYPE "E" TYPE "G" TYPE - E z x Z Q zP 24" 3'-8" 0 a W-6" RAISED FLOW ARROW z y RAISED FLOW ARROW 2�" 2�„ /8 HIGH �.1 o co; o N vv %8" HIGH D O - 2'-0" vv Ina O _1,2���D ff�zap 0.247 0.988 Z 1 /2,r -m 1 II /8 _ T =m 0 z = n _ 2'-0" a /811 9 N W w x D p o 1 i2 P O 11/2 1.474 0 0 z z v = 2'- 113/4 " 1 1/2 11 13/ „ I I %8 11/2 ��� 11 r 2' 11 " 11/2 R /811 CC w LL 3'-4" 13/" SECTION A -A 1 �2 I /8 4 1'-5" 2 TYPE - F TYPE G m SECTION A -A 3'-9" SHEET 2 OF 2 SHEET 2 OF 2 1.433 0.092 840.03 36" 3'-0" 840.03 v 0 H1 -4 Z Dcn 0 O FO_n cn mz =� m: >>m 2 0 O 0 Z FyO r_1 DDD cn ' Z n C) O Z n m m mZ O O r H1 1 _ cnN -4cn M =vz ova rn O v _ D M Z II M r z m c� � m m W SHEET 1 OF 1 840.18 1 PLAN FRAME AND GRATES TC Err A 6" 6„ 4, "- 4 .-F �^ �• q„ OUTLET PIPE 3„ SEE NOTE SECTION X -X GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL GRATED DROP INLETS OVER W-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. B40.OD. CONSTRUCT WITH PIPE CROWNS MATCHING. MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. USE STANDARD FRAMES AND GRATES 840.22 (SHOWN), 840.24(SHOWN), 840.20, 840.29, AND 840.33. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. CONCRETE APRON 4" SEE DETAIL 6" B 6" f OUTLET PIPE SEE NOTE DETAIL 6" MAX. PIPE THIS SIDE - 1B" (APRON SUPPORT NOTCH) SECTION Y -Y DITCH GRADE #4 BAR I 1 N I I I 1 I I I I l I I I I I r ---MEDIAN D.I. DOWEL "A" z 00 F_ HQ Q mmme LL _j N z 0053= _ QLL UCrO0 H CnHWOJ crOocnQ z > °c H > IL 1 C3 m W cr- LL o W z Jw 3 Z N Q " CL cr0 CL = O co C') 0co:3 Z Dc Q 0 W =aN CDT CD H J o W w W w v Z O v iHEET 1 OF 1 840.18 v vm I--1 -0 S 70000 6' Ems{ --I D #4 EB RS ISPACESI 6" 6" m z G)0> m J 1 „ S TIZ Dm = -0 -n z1�0 • {,� H1 c�X�D R R D ?v a 2co A 2 y cn O a� maLL z mj LL Lu aw aw iq m, c7 m' S -a p PLAN OF TOP SLAB SECTION S -S m !'! z O r- Z �0CD N m _ M 6" )-•- E #8 "W" BARS #4 BAR =M> mD #4 BARS S,, N � Z @ EQUAL SPACES a 0> rD _ � � v C) v 1 „ D W SECTION R -R DOWEL m a z N O1-4 Z SHEET 2 OF 2 840.02 v vm �' z 70000 Dom�O mz =� =�DDm =Cn�O zl�-0rm O DDD cn 0 I: � O i z EXPANSION JOINTS STD. 840.03 FRAME GRATE & HOOD I �6'-0" PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT GRADES 296 AND UNDER .y n I DEPRESSED GUTTER LINE EXPANSION JOINT r 1 1 m r--1�--�---1 ELEVATIOINI NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT 11 TOP USE ON GRADES OVER 2% ELEV. �vu -10IDEPRESSED GUTTER LINE EXPANSION JOINT 6'-01MAX. M ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE GRATED DROP INLET TOP ELEVATION PIPE SPAN WIDTH HEIGHT PIPE D CUBIC YARDS OF CONCRETE IN BOX MIN. HEIGHT H DEDUCTIONS FOR ONE PIPE D A B H BOTTOM SLAB H PER FT. HT. H MIN. TOTAL TOTAL C. S. R. C. 12" 3'-8" 2'-0" 2'-6" 0.362 0.247 0.597 0.958 0.020 0.032 15" 3'-8" 2'-0" 2'-9" 0.362 0.247 0.659 1.021 0.023 0.036 18" 3'-8" 2'-0" 3'-0" 0.362 0.247 0.720 1.OB2 0.033 0.049 24" 3'-8" 2'-0" W-6" 0.362 0.247 0.865 1.227 0.059 0.085 30 3'-8" 2'-0" 4'-0" 0.362 0.247 0.988 1.350 0.092 0.127 36 3'-8" 2'-0" 4'-6" 0.362 0.247 1.112 1.474 0.132 0.178 I 1 N I I I 1 I I I I l I I I I I r ---MEDIAN D.I. DOWEL "A" z 00 F_ HQ Q mmme LL _j N z 0053= _ QLL UCrO0 H CnHWOJ crOocnQ z > °c H > IL 1 C3 m W cr- LL o W z Jw 3 Z N Q " CL cr0 CL = O co C') 0co:3 Z Dc Q 0 W =aN CDT CD H J o W w W w v Z O v iHEET 1 OF 1 840.18 v vm I--1 -0 S 70000 6' Ems{ --I D #4 EB RS ISPACESI 6" 6" m z G)0> m J 1 „ S TIZ Dm = -0 -n z1�0 • {,� H1 c�X�D R R D ?v a 2co A 2 y cn O a� maLL z mj LL Lu aw aw iq m, c7 m' S -a p PLAN OF TOP SLAB SECTION S -S m !'! z O r- Z �0CD N m _ M 6" )-•- E #8 "W" BARS #4 BAR =M> mD #4 BARS S,, N � Z @ EQUAL SPACES a 0> rD _ � � v C) v 1 „ D W SECTION R -R DOWEL m a z N O1-4 Z SHEET 2 OF 2 840.02 v vm �' z 70000 Dom�O mz =� =�DDm =Cn�O zl�-0rm O DDD cn 0 I: � O i z EXPANSION JOINTS STD. 840.03 FRAME GRATE & HOOD I �6'-0" PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT GRADES 296 AND UNDER .y n I DEPRESSED GUTTER LINE EXPANSION JOINT r 1 1 m r--1�--�---1 ELEVATIOINI NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT 11 TOP USE ON GRADES OVER 2% ELEV. �vu -10IDEPRESSED GUTTER LINE EXPANSION JOINT 6'-01MAX. M ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES ^." WEEP HOLES 1X - -1 I Y ' PLAN WITH GRATE & FRAME REMOVED BRICK COPING(INCIDENTAL) m Z DIMENSIONS OF BOX & PIPE PIPE SPAN WIDTH MIN. HEIGHT TOP ELEVATION MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN BASED ON MIN. HEIGHT H WITH NO RISER BOTTOM WALL PER TOTAL Lo MIN EN SLAB FT. HTFon HEIGHT. GHT, M ZO fr-1 PIPE D DIMENSIONS OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G MIN. HEIGHT H COVER DIMENSION E F BARS -U N0. LENGTH BARS -V NO. LENGTH BARS -W NO. LENGTH TOTAL LBS. CU.YOS. CONC. IN BOX TOP BOTTOM TOT. CONC. SLAB SLAB ONIHT.HM HEI T H DEDUCTIONS ONE PIPE C. M. R. C. 12" W -O" 2'-2" -- -- 2'-9" -- -- -- -- -- -- -- -- -- -- 0.235 0.772 0.015 0.026 15" 3'-0" 2'-2" _n O 3'-0" � CA) O�1 : T Z N -I _ z c4 00 C7 = Iz -IC0 0.235 0.829 0.023 0.036 18" 3'-0" 2'-2" 3'-3" -) o N D 0.235 0.887 0.033 0.049 24" 3'-0" 2'-2" W-9" O 0.235 1.001 0.059 0.085 30" 3'-0" 2'-2" 3'-4" 4'-3" V-2" 4'-0" 4 1'-5" 2 3'-9" 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 36" 3'-0" 2'-2" W-10" 4'-9" 1' 8" 4'-0" 4 1'-11" 3 3'-9" 3 3'-9" 43 0.161 0.358 1.714 0.132 0.178 42" 3'-0" 2'-2" 4'-5" 5'-3" 1'-5" 3'-2" 4 1'-8" 2 2'-11" 3 2'-11" 32 0.112 0.318 1.738 0.180 0.243 48" 3'-0" 2'-2" 5'-0" 5'-9" 2'-0" 3'-2" 4 2'-3" 3 2'-11" 3 2'-11" 35 0 145 10.352 0 235 0 317 54" T-0" 2'-2" 5'-7" 6'_3" 2'_7" 3'-2" 4 2'-10" 5 2'-11" 3 2,_11" ^." WEEP HOLES 1X - -1 I Y ' PLAN WITH GRATE & FRAME REMOVED BRICK COPING(INCIDENTAL) m Z DIMENSIONS OF BOX & PIPE PIPE SPAN WIDTH MIN. HEIGHT TOP ELEVATION DEDUCTIONS FOR ONE PIPE D A B H BOTTOM WALL PER TOTAL Lo MIN EN SLAB FT. HTFon HEIGHT. GHT, M ZO fr-1 12" 3'-0" 2'-0" 2'-0" v STD. 840.16 FRAME - & GRATE N 0.648 0.023 0.036 18" 2'-6' 0.703 N _ = 24" 3'-0" 0.814 I 6 A 30" 3'-0" 2'-0" T-6" J 6„ m c-DGD c 6„ D M T T SECTION - NN rr^�^ vJ m Z Q) U W � z v D O O U) _n O TOP OF � CA) O�1 : T Z N -I _ z c4 00 C7 = Iz -IC0 CC ) W m cmi 3~zF_ w -) o N D m Z Z io SEE NOTE (SEE NOTE) SECTION X -X O OF 1 .14 2.052 41 0.180 0.386 2.387 0.297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER W-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. MAX. PIPE THIS SIDE SECTION Y -Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE PIPE SPAN WIDTH MIN. HEIGHT CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE D A B H BOTTOM WALL PER TOTAL Lo MIN EN SLAB FT. HTFon HEIGHT. GHT, M C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18" 2'-6' 0.703 _0.033 0.049 24" 3'-0" 0.814 0.059 0.085 30" 3'-0" 2'-0" T-6" J 0.222 0.222 0.925 0.092 0.127 #4 BAR N 6" DOWEL z O 0 �a Q H_q 0 U LLJaI-IZ O O 0 = cr Z Lu QU O0 C/) I- 0 J 0 0 U) Q z F•-1 1 CL 0 0 O Z LL N c� N Z a w 3 m CL �_D- 0 cr L0 o V = z C Q W F- H 0 W - D: N C T H Z J O C7 � Z W HEET 2 OF 2 840.02 z 00 HQ Q Z cc(=r}0 LLJdf-1Z 00in °C z Q 0=0CD H c/) LL 0 J 0 0 U) 1 CLZ H 0 0 2 O LL W cs J Z Z Lu H D- C CL 0 - O o � C 0 o = C LU < F- Cn W _ _ c N co T �Z J O zv W OF 1 .14 v z v mPAVEMENT 0 IC -1 z " rl %g" RAD. 9n 9n 3/4" RAD. 2" RAD. PAVEMENT 1, SURFACE Q Q mcn 0 1�" RAD. 6 2'- 0 - cr)/g" RAD. 1 „ SURFACE 1/8 RAD. 3r1 HH0 D"1 / RAD. v O Im-1 z --I _ 3" RAD . %g" RADE N ° o o cn = O C-) 0. I I C. "• Or 0 ?mZDm C:0 _ N - O. ;� 1/ O. O HUQO= D oC C7 =Goo v .�. LLJ •v'. �..: �.'.o N. :v.•�. ^ NOD .p.o. 1 Nco 2=�zH1 ZFyO r_1 p•v'.•.: p•v'. T �•.•.: .'p. 1�" RAD. cn HLL CODDD I. 2 6" .I 13/4rl RAD. it 611 ;u:•' p•'::� 00�� 1'-6" CURB AND GUTTER g" 91r N z F- H 0 ~ 2'-6" CURB AND GUTTER z 8" X 12" OR 18" 9" X 12" OR 18" 0 0 4'-0" PROPOSED CONCRETE CURB CONCRETE CURB 2'-011 2'-O" EDGE OF PAVEMENT _ 2" RAD. 2'-0" v,• •. 4:1 8rr 2'-4" MIN. %8" RADIUS of 1 Ir L0 1'-011 11_011 :o IA /4 12x1 v'•:: m :v: o . 6; :v.: o . :v. • o . �• :v: 0 7,r 00 0 . , • .v-• o . :v . a 51� 44° ¢, .:: !i Z o - :. 4 , o . • ... • o , P'::V. v. 6.. M I N : •.: 7 O �. a Z z In cn EXPRESSWAY GUTTER SHOULDER BERM GUTTER z Lu 8" X 6" MEDIAN CURB VALLEY GLITTER Q 7Co m z SECTION VIEW OF CURBS OR CURBS AND GUTTERS W C D CC otl 00 W v GENERAL NOTES: FILL 3/g" x 1" DEEP Q v -PLACE CONTRACTION JOINTS AT 10 INTERVALS, EXCEPT THAT GROOVED OR SAWN z 1= JOINT WITH JOINT Q W m C D A 15' SPACING MAY BE USED WHEN A MACHINE IS USED OR WHEN SEALER v -i G) *> SATISFACTORY SUPPORT FOR THE FACE FORM CAN BE OBTAINED JOINT SEALER W -i C '-' WITHOUT THE USE OF TEMPLATES AT 10' INTERVALS. „ 1/8" RAD. GUTTER m -JOINT SPACING MAY BE ALTERED IF REQUIRED BY THE ENGINEER. a. �8 RAD. PAVEMENT SURFACE 10-1 Z Z CONTRACTION JOINTS MAY BE INSTALLED WITH THE USE OF SURFACE J a O TEMPLATES OR FORMED BY OTHER APPROVED METHODS. :o•; :o•; : :a ..?,� ;a - z V = CONSTRUCT NON -TEMPLATE FORMED JOINTS A MIN. OF 111" DEEP. o o v :,•o. •v p p: p':...�:: p':...� r w -FILL ALL CONSTRUCTION JOINTS, EXCEPT IN 8"x6" MEDIAN CURB, :v' :o::. o.::o:: . v WITH JOINT FILLER AND SEALER. PROPOSED -SPACE EXPANSION JOINTS AT 90' INTERVALS AND ADJACENT TO CURB & GUTTER PROP. 112JO " � INT FILLER ALL RIGID OBJECTS. JOINT PAVEMENT LONGITUDINAL JOINT TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER SHEET 1 OF 3 SECTION VIEW OF JOINTS SHEET 1 OF 3 846.01 1846.011 v vm r-1 � O O FO _n 33 cn m z = -I =-nDDm =Cn3O z, -n G70, , D cn Fi O z -n o z C O CD r m m 0 O u = Z�cf) O -I n D Z v vmm >t/�v v� v cv Z 1c -I 0 v z = 0 x D CD O o O z SHEET 1 OF 2 840.03 43 NOTE: USE TYPE "E" "F" AND "G" GRATE UNLESS OTHERWISE NOTED. PLAN FRAME,GRATE, & HOOD ASS'Y SECTION - AA �'4 ' r •m 11 rr y4 x 16 v > T 3Y2" I 3' 0" 3W i SECTION - KK v vm H� mcf) 0 ' 1" DEPRESSION z�m: 1 -7%/ 1 -7`'/g =0>>m = O 00 N -rm O c)DDD � c C/) Z , SECTION G -G m 0 _ cnw m O z H O 2'-31/4" ZE H 2 Z U)r= v M � v 'nv 0 � D � v 11611 211 m v CO M 421 0 Z 1 v SECTION H -H Z z>0 v7D 00 m o N CI1 OF .1 v vm H_0 H' Z D10 0 10 F o �I -4 mz =� =-nZym x00o z 1--Ip F TI DDD O O ' Z SHEET 1 OF 2 848.03 ALIGN FRAME"IEN EDGE OF WAL FOR VERTICA SECTION - BB 21/6„ SECTION - LL T�� T SECTION - PP = I 3' - 0%8" i y2H 6" 2'-O" 6" „ Oy� I A " 4% >4 1 1�6" 2T'-1 1 L2„ R HOOD ELEVATION 11/2Cj 1/ 11/2 1811 yi�i�'8/1 r I r ,1�H 0 o� N �oEEHI HN 111- n\ 1'-4%2" 1' 41/2 r1 11-75/81r 11.781/ PLAN OF GRATING CAST IRON �B A o z Z) a m z ¢ 0 Ln 0 L0 o vF H CD -Iz m cn H = 21 " ujZ LL. HU�00 N N m SECTION - MM -0 D z H Y c-DGD c W _j 0 � C v QD T T SECTION - NN rr^�^ vJ m Z Q) U W 4 n _w O O U) _n O TOP OF � r SHEET 1 OF 2 848.03 ALIGN FRAME"IEN EDGE OF WAL FOR VERTICA SECTION - BB 21/6„ SECTION - LL T�� T SECTION - PP = I 3' - 0%8" i y2H 6" 2'-O" 6" „ Oy� I A " 4% >4 1 1�6" 2T'-1 1 L2„ R HOOD ELEVATION 11/2Cj 1/ 11/2 1811 yi�i�'8/1 r I r ,1�H 0 o� N �oEEHI HN 111- n\ 1'-4%2" 1' 41/2 r1 11-75/81r 11.781/ PLAN OF GRATING CAST IRON �B �T 7rr �1 SECTION - JJ 1�2 „ 1 12'r SECTION - RR 3'-6" F-1 E E fV-----i---- - I I 1 F PLAN OF FRAME CAST IRON X811 11811 181 l 18" 111 3'-33/" Yi,r 1„ 2'-33/4" 1/8' �B Ir 1/811 1/811 Tell 3/r, - Irr 3/" �/L� 3'-2" 21 211 VIA 21/ " 21/8" 3'-13/4" N N 2'- 13/4 N N 3'-6" 2'-611 SECTION E -E SECTION F -F *SIDEWALK TAPERS DOWN 5' BACK FROM DRIVEWAY. L-► B PLAN DETAIL OF DRIVEWAY SECTION A -A 2" DEEP SAW CUT • •' " EXISTING DRIVEWAY PROPOSED DRIVEWAY PAVEMENT PAVEMENT A METHOD OF TIE IN WHEN EXISTING DRIVEWAY PAVEMENT IS CONCRETE, SAW CUT 2" DEEP JOINT AT THE POINT OF TIE-IN. SAW JOINT PERPENDICULAR TO EDGE OF EXISTING DRIVEWAY PAVEMENT. WHEN DIRECTED. SECTION B -B GENERAL NOTES: **NO CONSTRUCTION JOINT WILL BE PERMITTED IF FORMS ARE USED TO CAST DRIVEWAY. SLIP FORMING OF CURB AND GUTTER PERMITS THE USE OF CONSTRUCTION JOINT. cr O n D N W 0 ~ Q a cn c Z x n O I H Wg w CD z Q = W LL. 1= O LL 1 OF 2 1.03 z 00 HQ Q HOC(=,}C.) LLJy1-Iz 000x =z Lu F-0�0CD H lnt-LL0J 0 0 Z U) li CL W D 1 0 N � W DD H OW z Q C7 � 1Z'1 Q T 3: Z 0 � a00 W 0 � O Cs Q CC O O I-- H = J O Z = z a W co 0 cr 0 LL SHEET 1 OF 1 840.16 z 00 M HQ Q H e-, U- _j O O O = Or Lu QUcr oLL H cnHLLO� OOr OcnQ z 1 a~ W 0 ' 0 0 LL z H 3 O w oZ CL °C� 0m ir cr 0 0 W 0 Cn > cc H 0 cn w H Q J cs z W HEET 1 OF 2 848.03 z O 0 Z) F- p P p 2E Ln 0 L0 o � Z m CD -Iz n zT 00cn o cc: 21 " ujZ LL. HU�00 N N 1-1 c~n�,�0� SECTION - MM 0 O " Q z H Y 14 /811 c u� I QD T T SECTION - NN rr^�^ vJ 4" Q) U W 4 n _w N O U) uT� U W Y LOm O�1 : T Z N -I _ z c4 00 C7 = Iz -IC0 WW ) W m cmi 3~zF_ �T 7rr �1 SECTION - JJ 1�2 „ 1 12'r SECTION - RR 3'-6" F-1 E E fV-----i---- - I I 1 F PLAN OF FRAME CAST IRON X811 11811 181 l 18" 111 3'-33/" Yi,r 1„ 2'-33/4" 1/8' �B Ir 1/811 1/811 Tell 3/r, - Irr 3/" �/L� 3'-2" 21 211 VIA 21/ " 21/8" 3'-13/4" N N 2'- 13/4 N N 3'-6" 2'-611 SECTION E -E SECTION F -F *SIDEWALK TAPERS DOWN 5' BACK FROM DRIVEWAY. L-► B PLAN DETAIL OF DRIVEWAY SECTION A -A 2" DEEP SAW CUT • •' " EXISTING DRIVEWAY PROPOSED DRIVEWAY PAVEMENT PAVEMENT A METHOD OF TIE IN WHEN EXISTING DRIVEWAY PAVEMENT IS CONCRETE, SAW CUT 2" DEEP JOINT AT THE POINT OF TIE-IN. SAW JOINT PERPENDICULAR TO EDGE OF EXISTING DRIVEWAY PAVEMENT. WHEN DIRECTED. SECTION B -B GENERAL NOTES: **NO CONSTRUCTION JOINT WILL BE PERMITTED IF FORMS ARE USED TO CAST DRIVEWAY. SLIP FORMING OF CURB AND GUTTER PERMITS THE USE OF CONSTRUCTION JOINT. cr O n D N W 0 ~ Q a cn c Z x n O I H Wg w CD z Q = W LL. 1= O LL 1 OF 2 1.03 z 00 HQ Q HOC(=,}C.) LLJy1-Iz 000x =z Lu F-0�0CD H lnt-LL0J 0 0 Z U) li CL W D 1 0 N � W DD H OW z Q C7 � 1Z'1 Q T 3: Z 0 � a00 W 0 � O Cs Q CC O O I-- H = J O Z = z a W co 0 cr 0 LL SHEET 1 OF 1 840.16 z 00 M HQ Q H e-, U- _j O O O = Or Lu QUcr oLL H cnHLLO� OOr OcnQ z 1 a~ W 0 ' 0 0 LL z H 3 O w oZ CL °C� 0m ir cr 0 0 W 0 Cn > cc H 0 cn w H Q J cs z W HEET 1 OF 2 848.03 W rn 0 Z) 0 OM Cc W OD m Ln 0 L0 o � Z m WV 0 o�0; z m M -� J Q N Z Y C U Q c W I ' , 'T_ W w z rr^�^ vJ z Q) U m L Q N N 'Q� U W Y O O�1 : T Z N m z c4 00 w Z WW W m cmi Q M a o N W Z) Cn Cc W OD m U W � Z m v J m J Q N Z Y Sheet C-5.0 0}O o W Cc W OD U W � Z m v J J Q N LL W Q O Y N I ' , 'T_ co rr^�^ vJ 0 W 0 W Y O m Q w Z W m cmi Sheet C-5.0 v vm H0 <' z ycnoo ro-1cn mz x� =-nDym x000 DDD cn O ' z M z O O r v NIn = ~m`n --I M z >-GD v M C O v m Z D C Z o 0 848.03 3 DESIRABLE DRIVEWAY GRADES *+2% GRADE WHEN *+2% GRADE WHEN THIS THIS IS SIDEWALK IS SIDEWALK LOCATION LOCATION ROADWAY PAVEMENT 6" _ *SIDEWALK LOCATION (DO NOT PLACE SIDEWALK ON BERMS LESS THAN 6' WIDE.) 5'-0" 5'-0" 5'-O" +15% OR FLATTER _ FLATTER +15% OR FLATTER _ _ - - 2% OR FLATTER 8� OR FLATTER_ 15?s OR F( qT7 ER DESIRABLE OR MAXIMUM DRIVEWAY GRADES BERM WIDTH A B DIST. GRADE DIST. GRADE 8' OR LESS 5'-0" +2%* 2'-6" +5% 8' OR LESS 2'-0" +6% 5'-6" +2%* 10' 4'-0" +4% 5'-6" +2%* 12' 8 OVER 4'-6" +4lb 7'-0" +2%* MAXIMUM DRIVEWAY GRADES BERM JrHIS A B 5'-0" 5'-0" 2% GRADE WHEN *+2% GRADE WHEN THIS IS SIDEWALK IS SIDEWALK LOCATION LOCATION +25'6 +1s% c-- - -_ 5' O„ ROADWAY PAVEMENT 4� -15� �-- z 00 �Q �� = aC-' LL JNZ 0053= QLu LL UCrO0 H- cnHLLOJ Ocr Ocn¢ Z ,>� F- H ao W x 0 LL Z H Ccn cr cc Q CC0 ¢ > ¢ ZaW P W H cl)>cr = 1-1 o H Q J C7 z W 848.03 v vM If z � COOO r0��� "z x> x-nZDm =000 z,, 0-o DDD cn 0 Z Ice, r M zM In 3 � r H cN � _ G < co _ z p a D D Z 0 �m > D C Z m C 0 Om mo o N = M v 1101 . INSET FOR 2 LANE ROADWAYS WITH 2 -WAY TURN LANE GENERAL NOTES FOR FLAGGER OPERATIONS ALL OTHER DEVICES ARE THE SAME AS ABOVE 1- REFER TO STD. 1101.11 SHEET 4 FOR SIGN SPACING. N RLW CLOSED x A A A RLW ♦ 1r CLOSED ♦ z COLu C) 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES THE POSTED SPEED LIMIT. ♦ 48.X 48" ♦♦ 48 48" TWO-WAY DOWN TRAFFIC BUFFER BUFFER STREAM TAPER SPACE SPACE TAPER 50'-100' 50' MIN. 50' MIN. 200' M 00 HQ H 0 LL-JO" oo�=z LLI LL H 0)�LL�J z O 1-1 °g HH �o 1 W 0 0 W 03 co o LL =J U CD C4 z 3 J J T C3 W } O x Z ao Z J O a °C co) GC Q _ 3� co O N Z W W WP Q J N 1101. GENERAL NOTES FOR FLAGGER OPERATIONS Z) 1- REFER TO STD. 1101.11 SHEET 4 FOR SIGN SPACING. 0 OM 2- INSTALL LANE CLOSURES WITH THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE UPSTREAM SIDE OF TRAFFIC. cn 3- REMOVE LANE CLOSURES AGAINST THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE DOWNSTREAM SIDE OF TRAFFIC. z COLu C) 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES THE POSTED SPEED LIMIT. o�cn 5- EXTEND LANE CLOSURES AT THE BUFFER SPACE SUCH THAT STOPPING SIGHT DISTANCE IS PROVIDED TO THE FLAGGER. (REFER TO STD. 1101.11 SHEET 2) a 6- DO NOT STOP TRAFFIC IN ANY ONE DIRECTION FOR MORE THAN 5 MINUTES AT A TIME. 0 7- DRUMS OR SKINNY -DRUMS MAY BE USED IN LIEU OF CONES. 0 8- USE FLAGGERS TO CONTROL TRAFFIC AT INTERSECTIONS AFFECTED BY THE LANE CLOSURE. SUPPLEMENT FLAGGERS LOCATED z AT INTERSECTIONS WITH FLAGGER AHEAD SIGNS (W20 -7a) PLACED APPROXIMATELY 250 FT. IN ADVANCE OF THE FLAGGER U Q WHERE INTERSECTIONS ARE SIGNALIZED AND PLACE SIGNALS IN THE FLASH MODE. W 9- FLAMERS SHALL NOT STAND IN THE ROADWAY. LEGEND GENERAL NOTES FOR PILOT CAR OPERATIONS W 1- USE PILOT CARS WHENDIRECTED BY THE ENGINEER. ♦ CONE 2- IF ROADWAY WIDTH IS LESS THAN 22 FEET (EDP TO EDP), CONES MAY NOT BE REQUIRED ALONG WORK AREA, A?z co AND AT THE DIGRESSION OF THE ENGINEER, CONES MAY BE OMITTED ALONG THE WORK AREA IF USING A PILOT CAR. PORTABLE SIGN (NOTE: CONES ARE ALWAYS REQUIRED IN THE UPSTREAM AND DOWNSTREAM TAPERS). FLAGGER 3- MOUNT SIGN 020-4 "PILOT CAR FOLLOW ME" AT A VISIBLE LOCATION ON THE REAR OF THE PILOT VEHICLE. DIRECTION OF TRAFFIC FLOW 4- DO NOT INSTALL MORE THAN ONE (1) MILE OF LANE CLOSURE, MEASURED FROM THE BEGINNING OF THE MERGE TAPER TO THE END OF THE LANE CLOSURE. L � Z N 5- ADVISE RESIDENTS AND BUSINESSES WITHIN THE LANE CLOSURE LIMITS ABOUT METHODS OF SAFE EGRESS AND INGRESS z FROM DRIVEWAYS DURING FLAGGING AND PILOT CAR OPERATIONS. M 00 HQ H 0 LL-JO" oo�=z LLI LL H 0)�LL�J z O 1-1 °g HH �o 1 W 0 0 W 03 co o LL =J U CD C4 z 3 J J T C3 W } O x Z ao Z J O a °C co) GC Q _ 3� co O N Z W W WP Q J N 1101. LL rn O Z) 0 OM cr m cn Lo o L" o z COLu C) WV o�cn m M a 0 Q N 0 M co o -Z z Y U Q c W N LLl W1 W O o z �� A?z co Q N N Qlt' u- TUc w v L � Z N M z 10 W Z c� WW co W � V) Q ,c>3 � M a � O N LL ct Z Z) cn cr m cn z COLu C) rn v J m a 0 Q N 0 z Y J W � CL z Lu —� U U Z cl- z z LuoLu Qw JJ m J (f) Wiz; uj W w z (f) o-Q� Q `` z U LIJ U 0uj Q�z J J_ m WWW WI Sheet C-5.1 ct Z CID cr m z COLu C) rn v J U J Q N LU O Y o Q N LLl m � — o W 0 w o M cn Q W Z c� co W � V) WWW WI Sheet C-5.1 3 STEEL POSTS (QUANTITY VAR.) PLASTIC SLOPE DRAIN PIPE (PRACTICE STANDARD 6.32) OR GEOTEXTILE LINING .D 14•m . TEMPORARY OR PERMANENT DITCH COIR FIBER BAFFLES (PRACTICE STANDARD 6.65) SKIMMER (SIZE VAR.) STONE PAD - PI ON VIF1A1 (below skimmer) TOP OF EMBANKMENT RISER STRUCTURE .� TRASH RACK 1' MIN. FREEBOARD - - -� 1' MIN. SKIMMER ��Py 11(( l 111II� 2ytiS)�ll_--`1)111 ii�i)i)I«�()I)I ISI g 1' CLASS B STONE PAD (4'X 4'X 1' MIN.) ANTIFL TATION BLOCK SECTIONAL VIEW RISER STRUCTURE /EMBANKMENT / STONE ENERGY F- DISSIPATOR WOOD STAI<E OR METAL POST ......0 - EMERGENCY SPILLWAY EMERGENCY SPILLWAY BARREL PIPE W/\ CUT-OFF ANTI -SEEP TRENCH COLLAR STABILIZED 2' DEEP OUTLET 1.1 NOTES 1. SEED AND PLACE MATTING FOR EROSION CONTROL ON INTERIOR AND EXTERIOR SIDESLOPES. 2. INSTALL A MINIMUM OF 3 COIR FIBER BAFFLES IN ACCORDANCE WITH PRACTICE STANDARD 6.65. 3. INSTALL SKIMMER AND COUPLING TO RISER STRUCTURE OR DIRECTLY INTO EMBANKMENT 1 FT. FROM BOTTOM OF BASIN. 4. THE ARM PIPE SHALL HAVE A MINIMUM LENGTH OF 6 FT. BETWEEN THE SKIMMER AND COUPLING. Plan View Inflow structure lip Average __ Area* Width W L * A rea of basin water surface at top of principal spillway elevation Inflow structure Figure 6.61d Sediment Basin (with Riser Barrel Pipe) Practice Standards and Specifications • Dewatering Allow the maximum reasonable detention period before the basin is completely dewatered (at least 48 hours). • Inflow rate Reduce the inflow velocity and divert all sediment -free 1-anofE Baffles I Baffles tl tl IE Lll Skimmer dewatering Emergency device spillway 1' Freeboard Embankment 1 ' A - 6" min, I 5ediinerlt Crass -Section Storage zone ViBw Figure 6.64c Example of a sediment basin with a skimmer outlet and emergency spillway. From Pennsylvania Erosion and Sediment Pollution Control Manual, March, 2000. Rev, 5113 6.64.7 NOT TO SCALE SEDIMENT BASIN (NCDEQ 6.61) SEE NCDEQ EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL FOR COMPLETE SPECIFICATIONS. CONSTRUCTION SPECIFICATIONS 1. SITE PREPARATIONS- CLEAR, GRUB, AND STRIP TOPSOIL FROM AREAS UNDER THE EMBANKMENT TO REMOVE TREES, VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL. DELAY CLEARING THE POOL AREA UNTIL THE DAM IS COMPLETE AND THEN REMOVE BRUSH, TREES, AND OTHER OBJECTIONABLE MATERIALS TO FACILITATE SEDIMENT CLEANOUT. STOCKPILE ALL TOPSOIL OR SOIL CONTAINING ORGANIC MATTER FOR USE ON THE OUTER SHELL OF THE EMBANKMENT TO FACILITATE VEGETATIVE ESTABLISHMENT. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW THE BASIN AS NEEDED. 2. CUT-OFF TRENCH- EXCAVATE A CUT-OFF TRENCH ALONG THE CENTER LINE OF THE EARTH FILL EMBANKMENT. CUT THE TRENCH TO STABLE SOIL MATERIAL, BUT IN NO CASE MAKE IT LESS THAN 2 FEET DEEP. THE CUT-OFF TRENCH MUST EXTEND INTO BOTH ABUTMENTS TO AT LEAST THE ELEVATION OF THE RISER CREST. MAKE THE MINIMUM BOTTOM WIDTH WIDE ENOUGH TO PERMIT OPERATION OF EXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE LESS THAN 2 FEET. MAKE SIDE SLOPES OF THE TRENCH NO STEEPER THAN 1:1. COMPACTION REQUIREMENTS ARE THE SAME AS THOSE FOR THE EMBANKMENT. KEEP THE TRENCH DRY DURING BACKFILLING AND COMPACTION OPERATIONS. 3. EMBANKMENT- TAKE FILL MATERIAL FROM THE APPROVED AREAS SHOWN ON THE PLANS. IT SHOULD BE CLEAN MINERAL SOIL, FREE OF ROOTS, WOODY VEGETATION, ROCKS, AND OTHER OBJECTIONABLE MATERIAL. SCARIFY AREAS ON WHICH FILL IS TO BE PLACED BEFORE PLACING FILL. THE FILL MATERIAL MUST CONTAIN SUFFICIENT MOISTURE SO IT CAN BE FORMED BY HAND INTO A BALL WITHOUT CRUMBLING. IF WATER CAN BE SQUEEZED OUT OF THE BALL, IT IS TOO WET FOR PROPER COMPACTION. PLACE FILL MATERIAL IN 6 TO 8 INCH CONTINUOUS LAYERS OVER THE ENTIRE LENGTH OF THE FILL AREA AND COMPACT IT. COMPACTION MAY BE OBTAINED BY ROUTING THE CONSTRUCTION HAULING EQUIPMENT OVER THE FILL SO THAT THE ENTIRE SURFACE OF EACH LAYER IS TRAVERSED BY AT LEAST ONE WHEEL OR TREAD TRACK OF HEAVY EQUIPMENT, OR A COMPACTOR MAY BE USED. CONSTRUCT THE EMBANKMENT TO AN ELEVATION 10 PERCENT HIGHER THAN THE DESIGN HEIGHT TO ALLOW FOR SETTLING. 4. CONDUIT SPILLWAYS- SECURELYATTACH THE RISER TO THE BARREL OR BARREL STUB TO MAKE A WATERTIGHT STRUCTURAL CONNECTION. SECURE ALL CONNECTIONS BETWEEN BARREL SECTIONS BY APPROVED WATERTIGHT ASSEMBLIES. PLACE THE BARREL AND RISER ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE OR ANTI -SEEP COLLARS. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4 -INCH LAYERS, AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. ANCHOR THE RISER IN PLACE BY ` CONCRETE OR OTHER SATISFACTORY MEANS TO PREVENT FLOTATION. IN NO CASE SHOULD THE �7 PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE � EMBANKMENT IS COMPLETE. 5. EMERGENCY SPILLWAY- INSTALL THE EMERGENCY SPILLWAY IN UNDISTURBED SOIL. THE �p ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE EMERGENCY SPILLWAY. 6. INLETS- DISCHARGE WATER INTO THE BASIN INA MANNER TO PREVENT EROSION. USE DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 7. EROSION CONTROL- CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY Lo; EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELYAFTER CONSTRUCTION (REFERENCES: SURFACE STABILIZATION). 8. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS BAFFLES. 9. SAFETY- SEDIMENT BASINS MAYATTRACT CHILDREN AND CAN BE DANGEROUS. AVOID STEEP SIDE SLOPES, AND FENCE AND MARK BASINS WITH WARNING SIGNS IF TRESPASSING IS Z• LIKELY. FOLLOWALL STATE AND LOCAL REQUIREMENTS. MAINTENANCE INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (112 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. SKIMMER SEDIMENT BASIN (NCDEQ 6.64) SEE NCDEQ EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL FOR COMPLETE SPECIFICATIONS. CKd Jh�I:lll��C�]►�6yd xd 1 �C�1_� ��Cd Ph7 1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 61NCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4 -INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4 -INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS, OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS -INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8 -INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTION(S) SHOULD OVERLAP THE LOWER SECTION(S) SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. (ADAPTED FROM 'A MANUAL FOR DESIGNING, INSTALLING AND MAINTAINING SKIMMER SEDIMENT BASINS." FEBRUARY, 1999. J. W. FAIRCLOTH & SON.). 8. INLETS -DISCHARGE WATER INTO THE BASIN INA MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENTLADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECT/ON). 9. EROSION CONTROL -CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION (REFERENCES: SURFACE STABILIZATION). 10. ALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS BAFFLES. 11. AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY (REFERENCES: SURFACE STABILIZATION). MAINTENANCE INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLYAND AFTER EACH SIGNIFICANT (ONE-HALF INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKINUNER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. BAFFLES WATER ENTRY UNIT WITH TRASH SCREEN ORIFICE OPENING INSIDE THE HORIZONTAL TUBE WITH A CONSTANT HYDRAULIC HEAD SCHEDULE 40 PVC PIPE (BARREL OR ARM) rl ^^T -FLEXIBLE HOSE END VIEW GENERAL NOTES: 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. 2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OF TIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE END OF THE PIPE. 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE. EMBANKMENT GENCY SPILLWAY MAXIMUM HEIGHT OF FLOAT WHEN NO OTHER /STORM WATER DISCHARGE OPENINGS EXIST (MAJOR STORM EVENT) \ INVERT OF LOWEST STORM WATER PVC VENT GRATE ISCHARGE OPENING PIPE (MINOR STORM EVENT) LOAT FLEXIBLE HOSE MUST BE SECURELY FASTENED TO THE PIPE STORM WATER /WATER QUALITY DISCHARGE DISCHARGE G OPENING \ OUTLET P FLEXIBLE HOSE NTRY UNIT SCHEDULE 40 PVC PIPE (BARREL OR ARM) SIDE VIEW MAINTAIN DEPRESSION TO �T (NO SCALE) MINIMIZE CHANCE OF SKIMMER' BECOMING STUCK DRAWN BY T. R. EVANS 10/10 J. W. FAIRCLOTH & SON INC. FAIRCLOTH SKIMMER DISCHARGE SYSTEM WITH OUTLET STRUCTURE WTELEP ONE: (91)732-1.COM TELEPHONE: (919) 732-1244 FAX: (919) 732-1266 EMAIL: WARREN@FAIRCLOTHSKIMMER.COM (NCDEQ 6.65) N. T. S. DEFINITION POROUS BARRIERS INSTALLED INSIDE A TEMPORARY SEDIMENT TRAP, ROCK DAM, SKIMMER BASIN, OR SEDIMENT BASIN TO REDUCE THE VELOCITY AND TURBULENCE OF THE WATER FLOWING THROUGH THE MEASURE, AND FACILITATE THE SETTLING OF SEDIMENT FROM THE WATER BEFORE DISCHARGE. PURPOSE SEDIMENT TRAPS AND BASINS ARE DESIGNED TO TEMPORARILY POOL RUNOFF WATER TO ALLOW SEDIMENT TO SETTLE BEFORE THE WATER IS DISCHARGED. UNFORTUNATELY, THEYARE USUALLY NOT VERY EFFECTIVE DUE TO HIGH TURBULENCE AND "SHORT-CIRCUITING" FLOWS WHICH TAKE RUNOFF QUICKLY TO THE OUTLET WITH LITTLE INTERACTION WITH MOST OF THE BASIN. BAFFLES IMPROVE THE RATE OF THE SEDIMENT RETENTION BY DISTRIBUTING THE FLOW AND REDUCING TURBULENCE. THIS PROCESS CAN IMPROVE SEDIMENT RETENTION. CONDITIONS WHERE PRACTICE APPLIES THIS PRACTICE SHOULD BE USED IN ANY TEMPORARY SEDIMENT TRAP, ROCK DAM, SKIMMER BASIN OR TEMPORARY SEDIMENT BASIN. PLANNING CONSIDERATION POROUS BAFFLES EFFECTIVELY SPREAD THE FLOW ACROSS THE ENTIRE WIDTH OFA SEDIMENT BASIN OR TRAP. WATER FLOWS THROUGH THE BAFFLE MATERIAL, BUT IS SLOWED SUFFICIENTLY TO BACK UP THE FLOW, CAUSING IT TO SPREAD ACROSS THE ENTIRE WIDTH OF THE BAFFLE (FIGURE 6.65A) SPREADING THE FLOW IN THIS MANNER UTILIZES THE FULL CROSS SECTION OF THE BASIN, WHICH IN TURN REDUCES FLOW RATES OR VELOCITYAS MUCH AS POSSIBLE. IN ADDITION, THE TURBULENCE IS ALSO GREATLY REDUCED. THE COMBINATION INCREASES SEDIMENT DEPOSITION AND RETENTION AND ALSO DECREASES THE PARTICLE SIZE OF SEDIMENT CAPTURED. THE INSTALLATION SHOULD BE SIMILAR TO A SEDIMENT FENCE (FIGURE 6.65B). MATERIALS SUCH AS 700 G/M2 COIR EROSION BLANKET (FIGURE 6.65D), COIR MESH, OR TREE PROTECTION FENCE FOLDED OVER TO REDUCE PORE SIZE HAVE BEEN USED SUCCESSFULLY. OTHER SIMILAR MATERIALS COULD WORK AS WELL. A SUPPORT WIRE OR ROPE ACROSS THE TOP WILL HELP PREVENT EXCESSIVE SAGGING IF THE MATERIAL IS ATTACHED TO IT WITH APPROPRIATE TIES. ANOTHER OPTION IS TO USE A SAWHORSE TYPE OF SUPPORT WITH THE LEGS STABILIZED WITH REBAR INSERTED INTO THE BASIN FLOOR. THESE STRUCTURES WORK WELL AND CAN BE PREFABRICATED OFF SITE AND QUICKLY INSTALLED. ANOTHER BAFFLE SYSTEM INVOLVES PLACING SILT FENCE FABRIC IN FRONT OF A WIRE FENCE (HOG WIRE) BACKING, AND SLITTING THE FABRIC IN ALTERNATING SQUARES (FIGURE 6.65B). THIS PERMITS FLOW THROUGH THE SILT FENCE SIMILAR TO MORE POROUS MATERIALS. DESIGN CRITERIA THE TEMPORARY SEDIMENT TRAP, ROCK DAM, OR TEMPORARY SEDIMENT BASIN SHOULD BE SIZED USING THE APPROPRIATE DESIGN CRITERIA. THE PERCENT OF SURFACE AREA FOR EACH SECTION OF THE BAFFLE ARE AS FOLLOWS: . INLET ZONE: 35% . FIRST CELL: 25% . SECOND CELL: 25% • OUTLET ZONE: 15% . BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES THAT DIVIDE THE BASIN IN THIRDS. BE SURE TO CONSTRUCT BAFFLES UP THE SIDE OF THE TRAP OR BASIN BANKS SO WATER DOES NOT FLOW AROUND THE STRUCTURES. MOST OF THE SEDIMENT WILL BE CAPTURED IN THE INLET ZONE. SMALLER PARTICLE SIZE SEDIMENTS ARE CAPTURED IN THE LATTER CELLS. BE SURE TO MAINTAIN ACCESS TO THE TRAP FOR MAINTENANCE AND SEDIMENT REMOVAL. THE DESIGN LIFE OF THE FABRIC IS 6-12 MONTHS, BUT MAY NEED TO BE REPLACE MORE OFTEN IF DAMAGED OR CLOGGED. CONSTRUCTION SPECIFICATIONS 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL POSTS OR SAWHORSES ACROSS THE WIDTH OF THE SEDIMENT TRAP. 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED A MAXIMUM OF 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 61NCHES HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 21NCHES LOWER THAN THE TOP OF THE BERMS. 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND THE OUTLET DISCHARGE POINT. BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES. 5. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. 6. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER A SAWHORSE OR THE TOP WIRE. HAMMER REBAR INTO THE SAWHORSE LEGS FOR ANCHORING. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE, OR STAPLES. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED INA TRENCH OR PINNED WITH 8 -INCH EROSION CONTROL MATTING STAPLES. 8. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN. MAINTENANCE INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OR A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHED HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. INLET FIGURE 6.65A POROUS BAFFLES IN A SEDIMENT BASIN. THE FLOW IS DISTRIBUTED EVENLY ACROSS THE BASIN TO REDUCE FLOW RATES AND TURBULENCE, RESULTING IN GREATER SEDIMENT RETENTION. BAFFLES NEED TO BE INSTALLED CORRECTLY IN ORDER TO FULLY PROVIDE THEIR BENEFITS. REFER TO FIGURE 6.65B AND THE FOLLOWING KEY POINTS: - THE BAFFLE MATERIAL NEEDS TO BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE . MOST OF THE SEDIMENT WILL ACCUMULATE IN THE FIRST BAY, SO THIS SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. SUPPORT ROPE SUPPORT POST STAKE TO OR WIRE TO A 24" INTO BOTTOM SUPPORT WIRE PREVENT SAGGING OR SIDE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE FIGURE 6.65B CROSS-SECTION OF A POROUS BAFFLE IN A SEDIMENT BASIN. NOTE THAT THERE IS NO WEIR BECAUSE THE WATER FLOWS THROUGH THE BAFFLE MATERIAL. OUTLET FIGURE 6.65C EXAMPLE OF POROUS BAFFLES USING COIR MESH. INLET ZONE 35% OF SURFACE AREA W rn 0 0 0 0 M L m � WV L � 0 o��; � z m O QU m � M ZCZ-� J � M J O ` ` o -Z ao [� U c O � Q W E o Z U a J Q N N �z� rO v J O LL � � - 4D W Q �W 9 o W D U m _u _M o N W cj� C0 L m � X11 W w Z � z m O QU m J � M J O ` ` Q ao 0 Y O O � z Sheet C-5.2 cj� M M o W L m � X11 W w Z � z m O QU J � M J O ` ` ao II z O Y o N O � m U, z rO v J O W � m Q w Z W D U m Sheet C-5.2 3 DEFINITION A GRAVELED AREA OR PAD LOCATED AT POINTS WHERE VEHICLES ENTER AND LEAVE A CONSTRUCTION SITE. PURPOSE TO PROVIDE A BUFFER AREA WHERE VEHICLES CAN DROP THEIR MUD AND SEDIMENT TO AVOID TRANSPORTING IT ONTO PUBLIC ROADS TO CONTROL EROSION FROM SURFACE RUNOFF AND TO HELP CONTROL DUST. CONDITIONS WHERE PRACTICE APPLIES WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND MOVING DIRECTLY ONTO A PUBLIC ROAD OR OTHER PAVED OFF-SITE AREA. CONSTRUCTION PLANS SHOULD LIMIT TRAFFIC TO PROPERLY CONSTRUCTED ENTRANCES. DESIGN CRITERIA AGGREGATE SIZE -USE 2-3 INCH WASHED STONE. DIMENSIONS OF GRAVEL PAD - THICKNESS: 6 INCHES MINIMUM WIDTH: 12 -FEET MINIMUM OR FULL WIDTH AT ALL POINTS OF THE VEHICULAR ENTRANCE AND EXIT AREA, WHICHEVER IS GREATER LENGTH: 50 -FEET MINIMUM LOCATION -LOCATE CONSTRUCTION ENTRANCES AND EXITS TO LIMIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES (FIGURE 6.06A). AVOID STEEP GRADES, AND ENTRANCES AT CURVES IN PUBLIC ROADS. WASHING -IF CONDITIONS AT THE SITE ARE SUCH THAT MOST OF THE MUD AND SEDIMENT ARE NOT REMOVED BY VEHICLES TRAVELING OVER THE GRAVEL, THE TIRES SHOULD BE WASHED. WASHING SHOULD BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE THAT DRAINS INTO A SEDIMENT TRAP OR OTHER SUITABLE DISPOSAL AREA. A WASH RACK MAY ALSO BE USED TO MAKE WASHING MORE CONVENIENT AND EFFECTIVE. CONSTRUCTION SPECIFICATIONS 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONS7RUC77ON SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2 - INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT (NCDENR 6.06) N.T.S. WIRE FI (IF APP WOVEN FILTER 4' MAX. I GENERAL NOTES: 1. SEDIMENT FILTER OUTLET SHALL BE 16 INCHES HIGH BUT NO TALLER THAN 18 INCHES. 2. CLASS 1 OR 2 RIP -RAP SHALL BE USED AND COVERED WITH 4 INCHES OF NCDOT #5 OR #57 WASHED STONE ON THE UPSLOPE SIDE. 3. POSTS SHALL BE NO MORE THAN 4 FEET APART. 4. SITE OUTLETS AT ANY POINT SMALL CONCENTRATED FLOWS ARE ANTICIPATED AND AT THE DIRECTION OF THE INSPECTOR. 5. ONE ACRE MAXIMUM DRAINAGE AREA PER OUTLET. SILT STONE • • • • • • • • • • • • # 5 WASHED STONE STD. 30.11 A GLE IRON 1911110lowumewumewl low ow, • • • • • • • • • • • • • • • • 0- I I_ Q NOTE: MAY BE USED WHERE EXTENSIVE HAULING WILL BE DONE. W Z 0- W �0 W (0U) MIN 6" PVC PIPE TO SEDIMENT TRAP A # 5 WASHED STONE STD. 30.11 A CLASS 1 OR 2 RIP -RAP t' MIN' ryA CONSTRUCTION ENTRANCE TRUCK TIRE WASH (IF REQUIRED BY TOWN ENGINEER) N. T. S. STEEL POST WASHED STONE (NCDOT #5 OR #57) i FLOW MAINTENANCE NOTES: 1. FILTER OUTLETS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. THE STONE SHALL BE REPLACED PROMPTLY AFTER ANY EVENT THAT HAS CLOGGED OR REMOVED IT. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OUTLET IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. FENCE OUTLET NOT TO SCALE WATER SUPPLY DEFINITION A SMALL TEMPORARY STONE DAM CONSTRUCTED ACROSS A DRAINAGE WAY. PURPOSE TO REDUCE EROSION IN A DRAINAGE CHANNEL BY REDUCING THE VELOCITY OF FLOW. CONDITIONS WHERE PRACTICE APPLIES THIS PRACTICE MAY BE USED AS A TEMPORARY MEASURE TO LIMIT EROSION BY REDUCING VELOCITY IN SMALL OPEN CHANNELS. WHEN NEEDED, THEY CAN BE USED IN CHANNELS, ROADSIDE DITCHES, AND TEMPORARY DIVERSIONS. CHECK DAMS MAY BE USED TO: • REDUCE VELOCITY IN SMALL TEMPORARY CHANNELS THAT ARE DEGRADING, BUT WHERE PERMANENT STABILIZATION IS IMPRACTICAL DUE TO THEIR SHORT PERIOD OF USEFULNESS; • REDUCE VELOCITY IN SMALL ERODING CHANNELS WHERE CONSTRUCTION DELAYS OR WEATHER CONDITIONS PREVENT TIMELY INSTALLATION OF NONEROSIVE LINERS. DO NOT USE CHECK DAMS IN INTERMITTENT OR PERENNIAL STREAMS. DESIGN CRITERIA THE FOLLOWING CRITERIA SHOULD BE USED WHEN DESIGNING A CHECK DAM: • THE DRAINAGE AREA IS LIMITED TO ONE HALF ACRE. • KEEP A MAXIMUM HEIGHT OF 2 FEET AT THE CENTER OF THE DAM • KEEP THE CENTER OF THE CHECK DAM AT LEAST 9 INCHES LOWER THAN THE OUTER EDGE AT NATURAL GROUND ELEVATION. • KEEP THE SIDE SLOPES OF THE DAM AT 2:1 OR FLATTER. • ENSURE THAT THE MAXIMUM SPACING BETWEEN DAMS PLACES THE TOES OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE TOP OF THE DOWNSTREAM DAM (FIGURE 6.83A) • STABILIZE OUTFLOW AREAS ALONG THE CHANNEL TO RESIST EROSION • USE NCDOT CLASS B STONE AND LINE THE UPSTREAM SIDE OF THE DAM WITH NCDOT #5 OR #57 STONE. • KEY THE STONE INTO THE DITCH BANKS AND EXTEND IT BEYOND THE ABUTMENTS A MINIMUM OF 1.5 FEET TO AVOID WASHOUTS FROM OVERFLOW AROUND THE DAM. CONSTRUCTION SPECIFICATIONS 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOW IN THE PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK (FIGURE 6.83B) TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM. 5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE CHECK DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. MAINTENANCE INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (112 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. DEFINITION A TEMPORARY SEDIMENT CONTROL MEASURE CONSISTING OF FABRIC BURIED AT THE BOTTOM, STRETCHED, AND SUPPORTED BY POSTS. PURPOSE TO RETAIN SEDIMENT FROM SMALL DISTURBED AREAS BY REDUCING THE VELOCITY OF SHEET FLOWS TO ALLOW SEDIMENT DEPOSITION. CONDITIONS WHERE PRACTICE APPLIES -BELOW SMALL -DISTURBED AREAS THAT ARE LESS THAN 1/4 ACRE ER 100 FEET OF FENCE. -WHERE RUNOFF CAN BE STORED BEHIND THE SEDIMENT FENCE WITHOUT DAMAGING THE FENCE OR THE SUBMERGED AREA BEHIND THE FENCE. -DO NOT INSTALL SEDIMENT FENCES ACROSS STREAMS, DITCHES, OR WATERWAYS, OR OTHER AREAS OF CONCENTRATED FLOW. • SEDIMENT FENCE SHOULD BE PLACED ALONG TOPOGRAPHIC ELEVATION CONTOURS, WHERE IT CAN INTERCEPT STORMWATER RUNOFF THAT IS IN DISPERSED SHEET FLOW. SEDIMENT FENCE SHOULD NOT BE USED ALONG BELOW GRADED SLOPES GREATER THAN 10 FEET IN HEIGHT. PLANNING CONSIDERATIONS A SEDIMENT FENCE IS A SYSTEM TO RETAIN SEDIMENT ON THE CONSTRUCTION SITE. THE FENCE RETAINS SEDIMENT PRIMARILY BY RETARDING FLOW AND PROMOTING DEPOSITION. IN OPERATION, GENERALLY THE FENCE BECOMES CLOGGED WITH FINE PARTICLES, WHICH REDUCE THE FLOW RATE. THIS CAUSES A POND TO DEVELOP BEHIND THE FENCE. THE DESIGNER SHOULD ANTICIPATE PONDING AND PROVIDE SUFFICIENT STORAGE AREAS AND OVERFLOW OUTLETS TO PREVENT FLOWS FROM OVERTOPPING THE FENCE. SINCE SEDIMENT FENCES ARE NOT DESIGNED TO WITHSTAND HIGH WATER LEVELS, LOCATE THEM SO THAT ONLY SHALLOW POOLS CAN FORM. TIE THE ENDS OF A SEDIMENT FENCE INTO HIGHER GROUND TO PREVENT FLOW AROUND THE END OF THE FENCE BEFORE THE POOL REACHES DESIGN LEVEL. CURLING EACH END OF THE FENCE UPHILL IN A "J" PATTERN MAY BE APPROPRIATE TO PREVENT END FLOW. PROVIDE STABILIZED OUTLETS TO PROTECT THE FENCE SYSTEM AND RELEASE STORM FLOWS THAT EXCEED THE DESIGN STORM. DEPOSITION OCCURS AS THE STORAGE POOL FORMS BEHIND THE FENCE. THE DESIGNER CAN DIRECT FLOWS TO SPECIFIED DEPOSITION AREAS THROUGH APPROPRIATE POSITIONING OF THE FENCE OR BY PROVIDING AN EXCAVATED AREA BEHIND THE FENCE. PLAN DEPOSITION AREAS AT ACCESSIBLE POINTS TO PROMOTE ROUTINE CLEANOUT AND MAINTENANCE. SHOW DEPOSITION AREAS IN THE EROSION AND SEDIMENTATION CONTROL PLAN. A SEDIMENT FENCE ACTS AS A DIVERSION IF PLACED SLIGHTLY OFF THE CONTOUR. A MAXIMUM SLOPE OF 2 PERCENT IS RECOMMENDED. THIS TECHNIQUE MAY BE USED TO CONTROL SHALLOW, UNIFORM FLOWS FROM SMALL DISTURBED AREAS AND TO DELIVER SEDIMENT -LADEN WATER TO DEPOSITION AREAS. THE ANCHORING OF THE TOE OF THE FENCE SHOULD BE REINFORCED WITH 12 INCHES OF NCDOT #5 OR #57 WASHED STONE WHEN FLOW WILL RUN PARALLEL TO THE TOE OF THE FENCE. SEDIMENT FENCES SERVE NO FUNCTION ALONG RIDGES OR NEAR DRAINAGE DIVIDES WHERE THERE IS LITTLE MOVEMENT OF WATER. CONFINING OR DIVERTING RUNOFF UNNECESSARILY WITH A SEDIMENT FENCE MAY CREATE EROSION AND SEDIMENTA77ON PROBLEMS THAT WOULD NOT OTHERWISE OCCUR. STRAW BARRIERS HAVE ONLY A 0-20% TRAPPING EFFICIENCY AND ARE INADEQUATE. STRAW BALES MAY NOT BE USED IN PLACE OF SEDIMENT FENCE. PREFABRICATED SEDIMENT FENCE WITH THE FABRIC ALREADY STAPLED TO THIN WOODEN POSTS DOES NOT MEET THE MINIMUM STANDARDS SPECIFIED LATER IN THIS SECTION. ANCHORING OF SEDIMENT FENCE IS CRITICAL. THE TOE OF THE FABRIC MUST BE ANCHORED IN A TRENCH BACKFILLED WITH COMPACTED EARTH. MECHANICAL COMPACTION MUST BE PROVIDED IN ORDER FOR THE FENCE TO EFFEC77VELY POND RUNOFF. WIR FILTER 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE STEEL POST - WIRE FENCE FILTER FABRIC 8" MIN. 4" MIN. N L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION FIGURE 6.83A SPACE CHECK DAMS IN A CHANNEL SO THAT THE CREST OF DOWNSTREAM DAM IS AT ELEVATION OF THE TOE OF UPSTREAM DAM 12" OF NCDOT #5 OR #57 WASHED STONE CLASS B RIPRAP FILTER CLOTH PLAN VIEW .5' 4' TO 6' CROSS SECTION VIEW Q Q Z �U N FIGURE 6.836 STONE CHECK DAM STONE SHOULD BE PLACED OVER THE CHANNEL BANKS TO KEEP WATER FROM CUTTING AROUND THE DAM. CHECK DAM (NCDENR 6.83) N. T. S. CONSTRUCTION SPECIFICATIONS MATERIALS 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D6461, WHICH IS SHOWN IN PART IN TABLE 6.62b. SYNTHETIC FILTER FABRIC SHOUD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 - 1201F. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT. STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. CONSTRUCTON 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE.(HIGHT FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLYAT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTED THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN TEH WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPOR TFENCE. SECURE FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE BY 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER (FIG. 6.62a) 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACHE FILTER FABRIC TO EXISTING TREES. INSTEAD OF EXCAVATING A TRENCH, PLACING FABRIC AND THEN BACKFILLING TRENCH, SEDIMENT FENCE MAY BE INSTALLED USING SPECIALLY DESIGNED EQUIPMENT THAT INSERTS THE FABRIC INTO A CUT SLICED IN THE GROUND WITH A DISC (FIG. 6.62b) la���r_��►�rrrr.�.��y�xyi�rNrrr.�.��� 1. THE BASE OF BOTH END POSTS SHOULD BE AT LEAST ONE FOOT HIGHER THAN THE MIDDLE OF THE FENCE. CHECK WITH A LEVEL IF NECESSARY. 2. INSTALL POSTS 4 FEET APART IN CRITICAL AREAS AND 6 FEET APART ON STANDARD APPLICATIONS. 3. INSTALL POSTS 2 FEET DEEP ON THE DOWNSTREAM SIDE OF THE SILT FENCE, AND AS CLOSE AS POSSIBLE TO THE FABRIC, ENABLING POSTS TO SUPPORT THE FABRIC FROM UPSTREAM WATER PRESSURE. 4. INSTALL POSTS WITH THE NIPPLES FACING AWAY FROM THE SILT FABRIC. 5. ATTACH THE FABRIC TO EACH POST WITH THREE TIES, ALL SPACED WITHIN THE TOP 8 INCHES OF THE FABRIC. ATTACH EACH TIE DIAGONALLY 45 DEGREES THROUGH THE FABRIC, WITH EACH PUNCTURE AT LEAST 1 INCH VERTICALLY APART. ALSO, EACH TIE SHOULD BE POSITIONED TO HANG ON A POST NIPPLE WHEN TIGHTENED TO PREVENT SAGGING. 6. WRAP APPROXIMATELY 61NCHES OF FABRIC AROUND THE END POSTS AND SECURE WITH 3 TIES. 7. NO MORE THAN 24 INCHES OF A 36 INCH FABRIC IS ALLOWED ABOVE GROUND LEVEL. 8. THE INSTALLATION SHOULD BE CHECKED AND CORRECTED FOR ANY DEVIATIONS BEFORE COMPACTION 9. COMPACTION IS VITALLY IMPORTANT FOR EFFECTIVE RESULTS. COMPACT THE SOIL IMMEDIATELY NEXT TO THE SILT FENCE FABRIC WIRE TIES WITH THE FRONT WHEEL OF THE TRACTOR, SKID STEER, OR ROLLER EXERTING AT LEAST 60 POINTS PER SQUARE INCH. COMPACT THE UPSTREAM SIDE FIRST, AND THEN EACH SIDE TWICE FOR A TOTAL OF 4 TRIPS. MAINTENANCE INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEKAND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. JURAL GROUND SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. STE­ WIRE FENCING WOVEN FILTER FABRIC 0 I N REMOVE ALL FENCING MATERIAL AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. SEDIMENT FENCE (NCDENR 6.62) N. T. S. 8' MAX. STEEL POST 0 WIRE FENCING ZFILTER FABRIC M w #5 WASHED STONE Lo M 1-t Z m O °a a N FLOW z m m M -� a O Q O _ M Q CL o -I-- Z O N -0. U Q c W - �1''� ui z m VW z U � m rO v J Q N N V U "t ' O 1'1 W LL i z N Q z o - ao °-� c4 o m m a � O N • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iiiiii • • • • • • • • • CLASS 1 OR 2 RIP -RAP t' MIN' ryA CONSTRUCTION ENTRANCE TRUCK TIRE WASH (IF REQUIRED BY TOWN ENGINEER) N. T. S. STEEL POST WASHED STONE (NCDOT #5 OR #57) i FLOW MAINTENANCE NOTES: 1. FILTER OUTLETS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. THE STONE SHALL BE REPLACED PROMPTLY AFTER ANY EVENT THAT HAS CLOGGED OR REMOVED IT. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OUTLET IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. FENCE OUTLET NOT TO SCALE WATER SUPPLY DEFINITION A SMALL TEMPORARY STONE DAM CONSTRUCTED ACROSS A DRAINAGE WAY. PURPOSE TO REDUCE EROSION IN A DRAINAGE CHANNEL BY REDUCING THE VELOCITY OF FLOW. CONDITIONS WHERE PRACTICE APPLIES THIS PRACTICE MAY BE USED AS A TEMPORARY MEASURE TO LIMIT EROSION BY REDUCING VELOCITY IN SMALL OPEN CHANNELS. WHEN NEEDED, THEY CAN BE USED IN CHANNELS, ROADSIDE DITCHES, AND TEMPORARY DIVERSIONS. CHECK DAMS MAY BE USED TO: • REDUCE VELOCITY IN SMALL TEMPORARY CHANNELS THAT ARE DEGRADING, BUT WHERE PERMANENT STABILIZATION IS IMPRACTICAL DUE TO THEIR SHORT PERIOD OF USEFULNESS; • REDUCE VELOCITY IN SMALL ERODING CHANNELS WHERE CONSTRUCTION DELAYS OR WEATHER CONDITIONS PREVENT TIMELY INSTALLATION OF NONEROSIVE LINERS. DO NOT USE CHECK DAMS IN INTERMITTENT OR PERENNIAL STREAMS. DESIGN CRITERIA THE FOLLOWING CRITERIA SHOULD BE USED WHEN DESIGNING A CHECK DAM: • THE DRAINAGE AREA IS LIMITED TO ONE HALF ACRE. • KEEP A MAXIMUM HEIGHT OF 2 FEET AT THE CENTER OF THE DAM • KEEP THE CENTER OF THE CHECK DAM AT LEAST 9 INCHES LOWER THAN THE OUTER EDGE AT NATURAL GROUND ELEVATION. • KEEP THE SIDE SLOPES OF THE DAM AT 2:1 OR FLATTER. • ENSURE THAT THE MAXIMUM SPACING BETWEEN DAMS PLACES THE TOES OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE TOP OF THE DOWNSTREAM DAM (FIGURE 6.83A) • STABILIZE OUTFLOW AREAS ALONG THE CHANNEL TO RESIST EROSION • USE NCDOT CLASS B STONE AND LINE THE UPSTREAM SIDE OF THE DAM WITH NCDOT #5 OR #57 STONE. • KEY THE STONE INTO THE DITCH BANKS AND EXTEND IT BEYOND THE ABUTMENTS A MINIMUM OF 1.5 FEET TO AVOID WASHOUTS FROM OVERFLOW AROUND THE DAM. CONSTRUCTION SPECIFICATIONS 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOW IN THE PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK (FIGURE 6.83B) TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM. 5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE CHECK DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. MAINTENANCE INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (112 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. DEFINITION A TEMPORARY SEDIMENT CONTROL MEASURE CONSISTING OF FABRIC BURIED AT THE BOTTOM, STRETCHED, AND SUPPORTED BY POSTS. PURPOSE TO RETAIN SEDIMENT FROM SMALL DISTURBED AREAS BY REDUCING THE VELOCITY OF SHEET FLOWS TO ALLOW SEDIMENT DEPOSITION. CONDITIONS WHERE PRACTICE APPLIES -BELOW SMALL -DISTURBED AREAS THAT ARE LESS THAN 1/4 ACRE ER 100 FEET OF FENCE. -WHERE RUNOFF CAN BE STORED BEHIND THE SEDIMENT FENCE WITHOUT DAMAGING THE FENCE OR THE SUBMERGED AREA BEHIND THE FENCE. -DO NOT INSTALL SEDIMENT FENCES ACROSS STREAMS, DITCHES, OR WATERWAYS, OR OTHER AREAS OF CONCENTRATED FLOW. • SEDIMENT FENCE SHOULD BE PLACED ALONG TOPOGRAPHIC ELEVATION CONTOURS, WHERE IT CAN INTERCEPT STORMWATER RUNOFF THAT IS IN DISPERSED SHEET FLOW. SEDIMENT FENCE SHOULD NOT BE USED ALONG BELOW GRADED SLOPES GREATER THAN 10 FEET IN HEIGHT. PLANNING CONSIDERATIONS A SEDIMENT FENCE IS A SYSTEM TO RETAIN SEDIMENT ON THE CONSTRUCTION SITE. THE FENCE RETAINS SEDIMENT PRIMARILY BY RETARDING FLOW AND PROMOTING DEPOSITION. IN OPERATION, GENERALLY THE FENCE BECOMES CLOGGED WITH FINE PARTICLES, WHICH REDUCE THE FLOW RATE. THIS CAUSES A POND TO DEVELOP BEHIND THE FENCE. THE DESIGNER SHOULD ANTICIPATE PONDING AND PROVIDE SUFFICIENT STORAGE AREAS AND OVERFLOW OUTLETS TO PREVENT FLOWS FROM OVERTOPPING THE FENCE. SINCE SEDIMENT FENCES ARE NOT DESIGNED TO WITHSTAND HIGH WATER LEVELS, LOCATE THEM SO THAT ONLY SHALLOW POOLS CAN FORM. TIE THE ENDS OF A SEDIMENT FENCE INTO HIGHER GROUND TO PREVENT FLOW AROUND THE END OF THE FENCE BEFORE THE POOL REACHES DESIGN LEVEL. CURLING EACH END OF THE FENCE UPHILL IN A "J" PATTERN MAY BE APPROPRIATE TO PREVENT END FLOW. PROVIDE STABILIZED OUTLETS TO PROTECT THE FENCE SYSTEM AND RELEASE STORM FLOWS THAT EXCEED THE DESIGN STORM. DEPOSITION OCCURS AS THE STORAGE POOL FORMS BEHIND THE FENCE. THE DESIGNER CAN DIRECT FLOWS TO SPECIFIED DEPOSITION AREAS THROUGH APPROPRIATE POSITIONING OF THE FENCE OR BY PROVIDING AN EXCAVATED AREA BEHIND THE FENCE. PLAN DEPOSITION AREAS AT ACCESSIBLE POINTS TO PROMOTE ROUTINE CLEANOUT AND MAINTENANCE. SHOW DEPOSITION AREAS IN THE EROSION AND SEDIMENTATION CONTROL PLAN. A SEDIMENT FENCE ACTS AS A DIVERSION IF PLACED SLIGHTLY OFF THE CONTOUR. A MAXIMUM SLOPE OF 2 PERCENT IS RECOMMENDED. THIS TECHNIQUE MAY BE USED TO CONTROL SHALLOW, UNIFORM FLOWS FROM SMALL DISTURBED AREAS AND TO DELIVER SEDIMENT -LADEN WATER TO DEPOSITION AREAS. THE ANCHORING OF THE TOE OF THE FENCE SHOULD BE REINFORCED WITH 12 INCHES OF NCDOT #5 OR #57 WASHED STONE WHEN FLOW WILL RUN PARALLEL TO THE TOE OF THE FENCE. SEDIMENT FENCES SERVE NO FUNCTION ALONG RIDGES OR NEAR DRAINAGE DIVIDES WHERE THERE IS LITTLE MOVEMENT OF WATER. CONFINING OR DIVERTING RUNOFF UNNECESSARILY WITH A SEDIMENT FENCE MAY CREATE EROSION AND SEDIMENTA77ON PROBLEMS THAT WOULD NOT OTHERWISE OCCUR. STRAW BARRIERS HAVE ONLY A 0-20% TRAPPING EFFICIENCY AND ARE INADEQUATE. STRAW BALES MAY NOT BE USED IN PLACE OF SEDIMENT FENCE. PREFABRICATED SEDIMENT FENCE WITH THE FABRIC ALREADY STAPLED TO THIN WOODEN POSTS DOES NOT MEET THE MINIMUM STANDARDS SPECIFIED LATER IN THIS SECTION. ANCHORING OF SEDIMENT FENCE IS CRITICAL. THE TOE OF THE FABRIC MUST BE ANCHORED IN A TRENCH BACKFILLED WITH COMPACTED EARTH. MECHANICAL COMPACTION MUST BE PROVIDED IN ORDER FOR THE FENCE TO EFFEC77VELY POND RUNOFF. WIR FILTER 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE STEEL POST - WIRE FENCE FILTER FABRIC 8" MIN. 4" MIN. N L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION FIGURE 6.83A SPACE CHECK DAMS IN A CHANNEL SO THAT THE CREST OF DOWNSTREAM DAM IS AT ELEVATION OF THE TOE OF UPSTREAM DAM 12" OF NCDOT #5 OR #57 WASHED STONE CLASS B RIPRAP FILTER CLOTH PLAN VIEW .5' 4' TO 6' CROSS SECTION VIEW Q Q Z �U N FIGURE 6.836 STONE CHECK DAM STONE SHOULD BE PLACED OVER THE CHANNEL BANKS TO KEEP WATER FROM CUTTING AROUND THE DAM. CHECK DAM (NCDENR 6.83) N. T. S. CONSTRUCTION SPECIFICATIONS MATERIALS 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D6461, WHICH IS SHOWN IN PART IN TABLE 6.62b. SYNTHETIC FILTER FABRIC SHOUD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 - 1201F. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT. STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. CONSTRUCTON 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE.(HIGHT FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLYAT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTED THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN TEH WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPOR TFENCE. SECURE FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE BY 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER (FIG. 6.62a) 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACHE FILTER FABRIC TO EXISTING TREES. INSTEAD OF EXCAVATING A TRENCH, PLACING FABRIC AND THEN BACKFILLING TRENCH, SEDIMENT FENCE MAY BE INSTALLED USING SPECIALLY DESIGNED EQUIPMENT THAT INSERTS THE FABRIC INTO A CUT SLICED IN THE GROUND WITH A DISC (FIG. 6.62b) la���r_��►�rrrr.�.��y�xyi�rNrrr.�.��� 1. THE BASE OF BOTH END POSTS SHOULD BE AT LEAST ONE FOOT HIGHER THAN THE MIDDLE OF THE FENCE. CHECK WITH A LEVEL IF NECESSARY. 2. INSTALL POSTS 4 FEET APART IN CRITICAL AREAS AND 6 FEET APART ON STANDARD APPLICATIONS. 3. INSTALL POSTS 2 FEET DEEP ON THE DOWNSTREAM SIDE OF THE SILT FENCE, AND AS CLOSE AS POSSIBLE TO THE FABRIC, ENABLING POSTS TO SUPPORT THE FABRIC FROM UPSTREAM WATER PRESSURE. 4. INSTALL POSTS WITH THE NIPPLES FACING AWAY FROM THE SILT FABRIC. 5. ATTACH THE FABRIC TO EACH POST WITH THREE TIES, ALL SPACED WITHIN THE TOP 8 INCHES OF THE FABRIC. ATTACH EACH TIE DIAGONALLY 45 DEGREES THROUGH THE FABRIC, WITH EACH PUNCTURE AT LEAST 1 INCH VERTICALLY APART. ALSO, EACH TIE SHOULD BE POSITIONED TO HANG ON A POST NIPPLE WHEN TIGHTENED TO PREVENT SAGGING. 6. WRAP APPROXIMATELY 61NCHES OF FABRIC AROUND THE END POSTS AND SECURE WITH 3 TIES. 7. NO MORE THAN 24 INCHES OF A 36 INCH FABRIC IS ALLOWED ABOVE GROUND LEVEL. 8. THE INSTALLATION SHOULD BE CHECKED AND CORRECTED FOR ANY DEVIATIONS BEFORE COMPACTION 9. COMPACTION IS VITALLY IMPORTANT FOR EFFECTIVE RESULTS. COMPACT THE SOIL IMMEDIATELY NEXT TO THE SILT FENCE FABRIC WIRE TIES WITH THE FRONT WHEEL OF THE TRACTOR, SKID STEER, OR ROLLER EXERTING AT LEAST 60 POINTS PER SQUARE INCH. COMPACT THE UPSTREAM SIDE FIRST, AND THEN EACH SIDE TWICE FOR A TOTAL OF 4 TRIPS. MAINTENANCE INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEKAND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. JURAL GROUND SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. STE­ WIRE FENCING WOVEN FILTER FABRIC 0 I N REMOVE ALL FENCING MATERIAL AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. SEDIMENT FENCE (NCDENR 6.62) N. T. S. 8' MAX. STEEL POST 0 WIRE FENCING ZFILTER FABRIC M w #5 WASHED STONE Lo M 1-t Z m O °a a N FLOW MIN. GENERAL NOTES: 1. WIRE FENCING SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. 2. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 3. STEEL POSTS SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 4. WIRE FENCING SHALL BE AT LEAST #10 GAGE WITH A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. 5. TURN SILT FENCE UP SLOPE AT ENDS. 6. WIRE MESH SHALL BE MIN. 13 GAGE WITH MAXIMUM 12" OPENINGS. 7. WIRE AND WASHED STONE IS REQUIRED TO BE SHOWN ON PLANS AT THE TOE OF SLOPES GREATER THAN 10 FEET VERTICAL (2:1 SLOPE) 8. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS ADJACENT TO SWIM BUFFERS, STREAMS OR WETLANDS (REFER TO SWIM BUFFER GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 9. DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 10. SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 11. DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. HIGH HAZARD TEMPORARY SILT FENCE N. T. S. W 0 Z) O O m zi m Lo M 1-t Z m O W V O C) (D z m m M -� a O Q O _ M Q CL o -I-- Z O N -0. U Q c W - �1''� ui z m VW z U � m rO v J Q N N V U "t ' O 1'1 W LL i z N Q z o - ao °-� c4 o m m a � O N W = Z) m m zi m U Z m O Q m a O 0 d Y Z O N J W CL z W -� U U C z z Lu oLu Qw J J m J w W wzU) Q 0 `` zuj � � � Qz J uj coO J_ m v J J = O m m zi uiW U Z m O Q O z o Y _W O O N co N UW z rO v J O W O 1'1 W m m Q W Z W C) m �, F CAl�0 O 1� O i ouslZ 5128118 Sheet C-5.3 FLOW CONTOUR 2 -FO S -FEET SELF FASTENER OVERLAP ANGLE STEEL POST (SEE NOTE 4) END HARDWARE CLOTH HERE WOOD MULCH OR COMPOST To V, HEIGHT OF COMPOST FILTERSOCK III IJP(; I �J PLAN -VIEW 12 -FEET OT (MIN.) 8 -FEET 24 -INCH FRTREXX® COMPOST FILTER SO( OR ENGINEER APPROVED EQUIVALENT f HARDWARE CLOTH L— — — — z Iu IIInI 5 -FEET SELF FASTENER ANGLE STEEL POST (SEE NOTE 3) HARDWARE CLOTH 2 -IN CH X 2 -INCH X 36 -INCH HARD WOODEN STAKE (SEE NOTE 2) 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT WOOD MULCH OR COMPOST TO Y2 I' HEIGHT OF COMPOST FILTER SOCK a III ', � II Tf TIIll (7111 r z "._.-I� ISH I Til I- �IHI SECTION B -B' 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT A' A SILT FENCE 2 -FOOT 2 -FOOT OVERLAP (MIN.) 2 -INCH X 2 -INCH X 36 -INCH HARD WOODEN STAKE (SEE NOTE 2) END HARDWARE CLOTH HERE -SILT FENCE 3 -FEET 3 -FEET 2 -FEET SECTION A -A' SILT FENCE OUTLET NOTES: 1. USE 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT. FILTER SOCKS SHALL BE A MINIMUM OF 12' LONG. MINIMUM OF 16 -INCH HEIGHT OF COMPOST FILTER SOCK AFTER INSTALLATION. 2. WATTLES ARE NOT TO BE USED IN PLACE OF COMPOST SOCK OR STONE. 3. HARD WOODEN STAKES SHALL BE INSTALLED THROUGH THE MIDDLE OF THE COMPOST FILTER SOCK. SPACE STAKES A MAXIMUM OF 3 -FEET. DRIVE THE STAKE TO A MINIMUM OF 1 -FOOT INTO THE GROUND LEAVING A MINIMUM OF 3 -INCH PROTRUDING ABOVE THE COMPOST FILTER SOCK. 4. OVERLAP SILT FENCE OUTLET OPENING WITH FILTER SOCK A MINIMUM OF 2 FEET, STARTING AT STEEL POST. EXTEND HARDWARE CLOTH AT LEAST 12 INCHES PAST STEEL POST. 5. USE HARDWARE CLOTH 24 GAUGE WIRE MESH WITH %" MESH OPENINGS. 6. SILT FENCE OUTLET LOCATIONS MAY VARY FROM THE APPROVED PLANS AS DIRECTED BY THE OWNER'S INSPECTOR OR DESIGNATED REPRESENTATIVE AND BASED UPON FIELD CONDITIONS. 7. SILT FENCE OUTLETS SHOULD BE INSTALLED AT POINTS OF CONCENTRATED FLOW AND LOW POINTS. IF WATER IS POOLING BEHIND INSTALLED SILT FENCE AN ADDITIONAL SILT FENCE OUTLET MAY NEED TO BE INSTALLED. SILT FENCE OUTLET INSPECTION & MAINTENANCE: 1. REGULAR INSPECTIONS OF SILT FENCE OUTLETS SHALL BE CONDUCTED ONCE EVERY CALENDAR WEEK AND, AS RECOMMENDED, WITHIN 24 -HOURS AFTER EACH RAINFALL EVENT THAT PRODUCES 1/2 -INCH OR MORE OF PRECIPITATION. 2. MAKE ANY NECESSARY REPAIRS IMMEDIATELY. 3. REMOVE ACCUMULATED SEDIMENT AND ANY DEBRIS. THE COMPOST SOCK MUST BE REPLACED IF CLOGGED OR TORN. 4. IF PONDING BECOMES EXCESSIVE, THE SOCK MAY NEED TO BE REPLACED WITH A LARGER DIAMETER OR A DIFFERENT MEASURE. THE SOCK NEEDS TO BE REINSTALLED IF UNDERMINED OR DISLODGED. 5. THE COMPOST SOCK SHALL BE INSPECTED UNTIL LAND DISTURBANCE IS COMPLETE AND THE AREA ABOVE THE MEASURE HAS BEEN PERMANENTLY STABILIZED. 6. SHOULD THE SILT FENCE ADJACENT TO THE OUTLET COLLAPSE, TEAR, OR BECOME INEFFECTIVE, REPAIR OR REPLACE IT PROMPTLY. 7. REMOVE ALL FENCING AND OUTLET MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. SILT FENCE OUTLET STRAW BALE STAPLES BINDING WIRE (2 PER BALE) 10 mil PLASTIC LINING WOOD OR METAL NATIVE MATERIAL STAKES (2 PER BALE) — (OPTIONAL) B L VARIES SECTION B -B' NOT TO SCALE 3m MINIMUM STAKE (TYP.) .� X- 10 mil PLASTIC LINING MR NOT TO SCALE TYPE "ABOVE GRADE" WITH STRAW BALES NOTES: 1. ACTUAL LAYOUT DETERMINED IN THE FIELD. 2. THE CONCRETE WASHOUT SIGN (SEE FIG, 4-15) SHALL BE INSTALLED WITHIN 10 m OF THE TEMPORARY CONCRETE WASHOUT FACILITY. B' tSTRAW BALE (TYP.) CONCRETE 1 ; WASHOUT T I+I I+I 915 mm 915 mm Id CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) PLYWOOD 1200 mm x 610 mm PAINTED WHITE BLACK LETTERS 150 mm HEIGHT LAG SCREWS (12.5 mm) WOOD POST (89mmx89mmx2.4m) I+ 50 mm 3.05 mm DIA. 200 mm~' STEEL WIRE STAPLE DETAIL CONCRETE WASHOUT BASIN N. T. S. 3 LENGTH AS NECESSARY TO GO THRU DIKE 4' MIN. PIPE 1.5' MIN FLEXIBLE PIPE TIE DOWN 10' MAX. SPACING TIE DOWN AT END—�\ \ 4' * AT LESS THAN 1% SLOPE DIAMETER (D) PROFILE EXTEND TO EDGE OF RIP RAP & WASHED STONE FILTER BERM (MCLDS 30.12) — -SEDIMENT PITAf 77� 'T. a � a = w � STAKES' , a ' a EARTH DIKE a a a SEDIMENT PIT NOT REQUIRED IF BASIN IS LOCATED DOWNSTREAM OF PIPE OUTLET. (VOLUME PER MCLDS 30.12) CONSTRUCTION SPECIFICATIONS: 1. THE TOP OF THE EARTH DIKE OVER THE INLET PIPE AND THOSE 4. THE SOIL AROUND AND UNDER THE INLET PIPE AND ENTRANCE DIKES CARRYING WATER TO THE PIPE SHALL BE AT LEAST 1.5 FEET SECTION SHALL BE HAND TAMPED IN 4" LIFTS TO THE TOP OF HIGHER AT ALL POINTS THAN THE TOP OF THE INLET PIPE. THE EARTH DIKE. 2. THE PIPE SHALL BE FLEXIBLE WITH WATER TIGHT CONNECTING 5. FOLLOW—UP INSPECTION AND ANY NEEDED MAINTENANCE SHALL BANDS. FLEXIBLE PIPE SHOULD BE STAKED ON EITHER SIDE. BE PERFORMED AFTER EACH STORM BY THE FINANCIALLY RESPONSIBLE 3. A RIP RAP APRON SHALL BE PROVIDED AT THE OUTLET, IF PARTY OR HIS AGENT. EMPTYING INTO A DISTURBED AREA. 6. OUTLET PIPE SHOULD BE TAKEN OVER OR THROUGH ANY SILT FENCE, TAKING CARE NOT TO VOID THE EFFECTIVENESS OF THE SILT FENCE. FLEX BLE PPE SLOPE DRAIN NOT TO SCALE rn 0 WOOD MULCH OR Q 0 Lo oM 0 COMPOST TO Y, HEIGHT U) Lo co O OF COMPOST FILTER 2 -INCH X 2 -INCH % 36 INCH BI �� SOCK HARD WOODEN STAKE M a (SEE NOTE 2) c A - 2 -FEET 3 -FEET 3 -FEET 2 -FEET z o z a� Uami 0 N �() Q N N �U-N't O c� f 5 -FEET SELF) SILT FENCE L- Z N 7 FASTENER ANGLE ° -FOOT B fJ STEEL POST _.2 � o (SEE NOTE 3) 2 -FO S -FEET SELF FASTENER OVERLAP ANGLE STEEL POST (SEE NOTE 4) END HARDWARE CLOTH HERE WOOD MULCH OR COMPOST To V, HEIGHT OF COMPOST FILTERSOCK III IJP(; I �J PLAN -VIEW 12 -FEET OT (MIN.) 8 -FEET 24 -INCH FRTREXX® COMPOST FILTER SO( OR ENGINEER APPROVED EQUIVALENT f HARDWARE CLOTH L— — — — z Iu IIInI 5 -FEET SELF FASTENER ANGLE STEEL POST (SEE NOTE 3) HARDWARE CLOTH 2 -IN CH X 2 -INCH X 36 -INCH HARD WOODEN STAKE (SEE NOTE 2) 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT WOOD MULCH OR COMPOST TO Y2 I' HEIGHT OF COMPOST FILTER SOCK a III ', � II Tf TIIll (7111 r z "._.-I� ISH I Til I- �IHI SECTION B -B' 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT A' A SILT FENCE 2 -FOOT 2 -FOOT OVERLAP (MIN.) 2 -INCH X 2 -INCH X 36 -INCH HARD WOODEN STAKE (SEE NOTE 2) END HARDWARE CLOTH HERE -SILT FENCE 3 -FEET 3 -FEET 2 -FEET SECTION A -A' SILT FENCE OUTLET NOTES: 1. USE 24 -INCH FILTREXX® COMPOST FILTER SOCK OR ENGINEER APPROVED EQUIVALENT. FILTER SOCKS SHALL BE A MINIMUM OF 12' LONG. MINIMUM OF 16 -INCH HEIGHT OF COMPOST FILTER SOCK AFTER INSTALLATION. 2. WATTLES ARE NOT TO BE USED IN PLACE OF COMPOST SOCK OR STONE. 3. HARD WOODEN STAKES SHALL BE INSTALLED THROUGH THE MIDDLE OF THE COMPOST FILTER SOCK. SPACE STAKES A MAXIMUM OF 3 -FEET. DRIVE THE STAKE TO A MINIMUM OF 1 -FOOT INTO THE GROUND LEAVING A MINIMUM OF 3 -INCH PROTRUDING ABOVE THE COMPOST FILTER SOCK. 4. OVERLAP SILT FENCE OUTLET OPENING WITH FILTER SOCK A MINIMUM OF 2 FEET, STARTING AT STEEL POST. EXTEND HARDWARE CLOTH AT LEAST 12 INCHES PAST STEEL POST. 5. USE HARDWARE CLOTH 24 GAUGE WIRE MESH WITH %" MESH OPENINGS. 6. SILT FENCE OUTLET LOCATIONS MAY VARY FROM THE APPROVED PLANS AS DIRECTED BY THE OWNER'S INSPECTOR OR DESIGNATED REPRESENTATIVE AND BASED UPON FIELD CONDITIONS. 7. SILT FENCE OUTLETS SHOULD BE INSTALLED AT POINTS OF CONCENTRATED FLOW AND LOW POINTS. IF WATER IS POOLING BEHIND INSTALLED SILT FENCE AN ADDITIONAL SILT FENCE OUTLET MAY NEED TO BE INSTALLED. SILT FENCE OUTLET INSPECTION & MAINTENANCE: 1. REGULAR INSPECTIONS OF SILT FENCE OUTLETS SHALL BE CONDUCTED ONCE EVERY CALENDAR WEEK AND, AS RECOMMENDED, WITHIN 24 -HOURS AFTER EACH RAINFALL EVENT THAT PRODUCES 1/2 -INCH OR MORE OF PRECIPITATION. 2. MAKE ANY NECESSARY REPAIRS IMMEDIATELY. 3. REMOVE ACCUMULATED SEDIMENT AND ANY DEBRIS. THE COMPOST SOCK MUST BE REPLACED IF CLOGGED OR TORN. 4. IF PONDING BECOMES EXCESSIVE, THE SOCK MAY NEED TO BE REPLACED WITH A LARGER DIAMETER OR A DIFFERENT MEASURE. THE SOCK NEEDS TO BE REINSTALLED IF UNDERMINED OR DISLODGED. 5. THE COMPOST SOCK SHALL BE INSPECTED UNTIL LAND DISTURBANCE IS COMPLETE AND THE AREA ABOVE THE MEASURE HAS BEEN PERMANENTLY STABILIZED. 6. SHOULD THE SILT FENCE ADJACENT TO THE OUTLET COLLAPSE, TEAR, OR BECOME INEFFECTIVE, REPAIR OR REPLACE IT PROMPTLY. 7. REMOVE ALL FENCING AND OUTLET MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. SILT FENCE OUTLET STRAW BALE STAPLES BINDING WIRE (2 PER BALE) 10 mil PLASTIC LINING WOOD OR METAL NATIVE MATERIAL STAKES (2 PER BALE) — (OPTIONAL) B L VARIES SECTION B -B' NOT TO SCALE 3m MINIMUM STAKE (TYP.) .� X- 10 mil PLASTIC LINING MR NOT TO SCALE TYPE "ABOVE GRADE" WITH STRAW BALES NOTES: 1. ACTUAL LAYOUT DETERMINED IN THE FIELD. 2. THE CONCRETE WASHOUT SIGN (SEE FIG, 4-15) SHALL BE INSTALLED WITHIN 10 m OF THE TEMPORARY CONCRETE WASHOUT FACILITY. B' tSTRAW BALE (TYP.) CONCRETE 1 ; WASHOUT T I+I I+I 915 mm 915 mm Id CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) PLYWOOD 1200 mm x 610 mm PAINTED WHITE BLACK LETTERS 150 mm HEIGHT LAG SCREWS (12.5 mm) WOOD POST (89mmx89mmx2.4m) I+ 50 mm 3.05 mm DIA. 200 mm~' STEEL WIRE STAPLE DETAIL CONCRETE WASHOUT BASIN N. T. S. 3 LENGTH AS NECESSARY TO GO THRU DIKE 4' MIN. PIPE 1.5' MIN FLEXIBLE PIPE TIE DOWN 10' MAX. SPACING TIE DOWN AT END—�\ \ 4' * AT LESS THAN 1% SLOPE DIAMETER (D) PROFILE EXTEND TO EDGE OF RIP RAP & WASHED STONE FILTER BERM (MCLDS 30.12) — -SEDIMENT PITAf 77� 'T. a � a = w � STAKES' , a ' a EARTH DIKE a a a SEDIMENT PIT NOT REQUIRED IF BASIN IS LOCATED DOWNSTREAM OF PIPE OUTLET. (VOLUME PER MCLDS 30.12) CONSTRUCTION SPECIFICATIONS: 1. THE TOP OF THE EARTH DIKE OVER THE INLET PIPE AND THOSE 4. THE SOIL AROUND AND UNDER THE INLET PIPE AND ENTRANCE DIKES CARRYING WATER TO THE PIPE SHALL BE AT LEAST 1.5 FEET SECTION SHALL BE HAND TAMPED IN 4" LIFTS TO THE TOP OF HIGHER AT ALL POINTS THAN THE TOP OF THE INLET PIPE. THE EARTH DIKE. 2. THE PIPE SHALL BE FLEXIBLE WITH WATER TIGHT CONNECTING 5. FOLLOW—UP INSPECTION AND ANY NEEDED MAINTENANCE SHALL BANDS. FLEXIBLE PIPE SHOULD BE STAKED ON EITHER SIDE. BE PERFORMED AFTER EACH STORM BY THE FINANCIALLY RESPONSIBLE 3. A RIP RAP APRON SHALL BE PROVIDED AT THE OUTLET, IF PARTY OR HIS AGENT. EMPTYING INTO A DISTURBED AREA. 6. OUTLET PIPE SHOULD BE TAKEN OVER OR THROUGH ANY SILT FENCE, TAKING CARE NOT TO VOID THE EFFECTIVENESS OF THE SILT FENCE. FLEX BLE PPE SLOPE DRAIN NOT TO SCALE uj rn 0 Z) Q 0 Lo oM 0 m U) Lo co O Z m cu M -n Q M Z m O _ M a c z Lu uj z o z a� Uami 0 N �() Q N N �U-N't O c� } m L- Z N 7 ° r0 vJ M a � o O N uj = Z) Q V) m U) ui2 Ct) Z m O u a z J W � CL z W -� U Uuj z z uj 0 Lu J Jca J uj W w z Q `` zLU (i� � Qz OD J uj co C) J_ m J = Q m m ui2 U Z m O QU z o Y 0 N O c� } m z ° r0 vJ w o m Q W Z c� W C-5.4 3 NOTE: A 27" DIAMETER PRE -CAST RING SHALL BE PLACED 8 3/4" AROUND EACH VALVE BOX. 7 1/2" F-2.. 43/4"� TOP —1/4" 7 1 1 BOTTOM {SCREW TYPE) 7 3/8" 1/4" 1/2.. � 3f4" � r 11/2" 5/16" 5 1 S 1/2" X63/4"� 11/2' 1" O WATER 0 COVER 31 UNION COUNTY PUBLIC WORKS DEPARTMENT HIVUH RU VC HIL VALVE Box SCALE UNION COUNTY, N.C. N.T.S. GATE: 11-17-06 N0. 67 WASHED STONE BURY 18"x18"x6" UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N,C, 41„ PAINT COLORS BODY...................FIRE HYDRANT RED - RUST-OLEUM ENAMEL # 1210 FIRE HYDRANT RED BONNET...............HIGH GLOSS WHITE - RUST-OLEUM ENAMEL # 2766 CAPS....................HIGH GLOSS WHITE - RUST-OLEUM ENAMEL # 2766 HYDRANTS TO BE SET AT BURY LINE- EDGE OF R/W AT PROPERTY TO BE SET AT CORNERS EXIST. GRADE LEVEL 6" MECHANICAL JOINT 6" DUCTILE IRON GATE VALVE LEADER WITH MEGALUGS 14 GA. STRANDED BLUE COATED `COPPER TRACER WIRE O O MECHANICAL JOINT cE O O "LOCKED" HYDRANT TEE O O A MINIMUM OF 6" OF CONCRETE WILL BE PLACED UNDER THE BASE STANDARD DETAIL FIRE HYDRANT INSTALLATION SD 1- CONCRETE PAD cllIl I I—1 I I VALVE BOX HYDRANT TEE 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE ,III=I 1 - 1 ll 6" PVC PIPE 3 2" CAST IRON HARCO ADAPTOR 8" OR 6" WATERMAIN_ 2" PVC (54 LF DIP RESTRAINT) 2' OF 2" BRASS NIPPLE \\-2" THREADED VALVE 6X2 MJ PLUG UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL HYDRANT TEE X2" REDUCERNALE: SC.TS.UNION COUNTY, N.C, DATE: 7 A 10-4-11 CONCRETE PAD UNION COUNTY PUBLIC WORKS DEPARTMENT l [Vr l,V VL 4 fIIL SCALE: UNION COUNTY, N.C. VALVE BOX INSTALLATION 104il 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. SADDLE COPPER SERVICE TUBING CONNECTOR CORPORATION APPROVED SERVICE HARDWARE 2 PVC MUELLER H-13420 FORD S70 SADDLE UP TO 8" SEE NOTE FC 101 BALL CORPORATION B-25008 F81000G YOKE H-5020 Y 502 ANGLE BALL VALVE B-24273 BA94-323WG CHECK VALVE H -14247—A HHS91-323 CONNECTORS COPPER STYLE 110 GRIP JOINT EXPANSION CONNECTION 4" EC 23 NOTE: ROMAC 101N SHALL REPLACE MUELLER FOR PIPE DIAMETER UP TO 8" SMITH BLAIR 317, FORD FC 202 OR ROMAC 202N SHALL REPLACE MUELLER FOR PIPE DIA, 12" AND UP STANDARD DETAIL SERV CE CO ECT 01� SCALE: S kN.T.S. DATE: 10-4-11 CONCRETE PAD _ e VALVE BOX -c 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE ed�a.. e.. ,•. —I dill IIIII�II - 1 6" PVC PIPE 2" CAST IRON HARCO ADAPTOR 8" OR 6" WATERMAIN 2" PVC (54 LF QIP RESTRAINT) 2' OF 2" BRASS NIPPLE \_2" THREADED VALVE 6X2 MJ PLUG UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL 8" OR 6"X2" REDUCER SCALE: UNION COUNTY, N.C. N. UNION DATE: 10-4-11 CONCRETE RING 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE---,-' 2" WATER MAIN UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. GROUND LEVEL TERMINATE 1' BELOW GROUND LEVEL VALVE BOX 2 COUPLING 1 6" PVC PIPE RESTING ON BRICK 2" GATE VALVE — MECHANICAL JOINT GENERAL NOTES: 1) METER BOX LID TO HAVE AMR LOCATOR (ALLIANCE 1200 OR EQUAL FOR 5OW ERT, STANDARD LID FOR 60W ERT) 21 BUILDER/PROPERTY OWNER TO INSTALL NIPPLE, VALVE AND VALVE BOX BEFORE METER WILL BE SET. 3h METER AND ERT BY UNION COUNTY @ PREVAILING RATE —VALVE BOX 2" GALVANIZED PIPE 2' LONG e e 2' GALVANIZED PIPE 3' LONG— " 2 90° BEND CONCRETE BLOCKING STANDARD DETAIL 2" BLOW -OFF L ELECTRONIC RADIO TRANSMITTER VALVE BOX BY BUILDER/PROPERTY OWNER F -, 14 GAUGE STRANDED 8" to 10"J I L BLUE COATED COPPER 1 I TRACER WIRE ANGLE VALVE ' I (WITH LOCK WINGS) I EXPANSION I I I CONNECTOR 1 1/2" AMR METER I I I _ I CLEARANCE I = I --- - - - - - - lilImlpI 14 4 --------- H�_A➢ ZCHECK VALVE \--VALVE BY BUILDER/PROPERTY OWNER TUBING CONNECTOR YOKE BRASS NIPPLE BY BUILDER/PROPERTY OWNER UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL NGTSE UNION COUNTY, N.C. METER NSTALLAT ON FOR AMR METERS °2;4 Lu rn 0 Z) 0 oM m \/ J Lo 0 L0 co z m O� WV 0 z m � M -� a CL W M O _� z P U Q c 4" Z* ... �W W CONCRETE 4 1/2 OF PIPE DIA. STONE Z m U CLASS A CLASS B NOTES: !Lr- 42 W ALL CONCRETE = 3000 PSI z m ALL STONE = N.C.D.O.T. N0, 67 WW UNION COUNTY PUBLIC WORKS DEPARTMENT Ma STANDARD DETAIL Q SCALE: UNION COUNTY, N.C. P P E BEDDING N.T.S. U DATE: 11-17-d6 Lu rn 0 Z) 0 oM m \/ J Lo 0 L0 co z m O� WV 0 z m � M -� a CL W M O _� z Y U Q c W Z* � �W W m z Z m U V !Lr- 42 W u- - Z N z m WW Com D Ma o� N Lu Z Z) C/)m m \/ J W U z m O� J a 0 W M O _� z Y J W CL z W � U U ��z oQLuw J J m J w w wz� z uj Q�z uj co OD m QN_ J C) J_ m \\Ilullnll,,, CAIt'0,��,, 1 9 •FIOUSZ� ,,� , /// /1111111II111 �\\\ 5/28/18 Sheet G5.5 Z m m \/ J W U z m O� J Q W M _� Q � O Y � N � m J 0 W 0 W o z m Q w Z �D Com D N �n \\Ilullnll,,, CAIt'0,��,, 1 9 •FIOUSZ� ,,� , /// /1111111II111 �\\\ 5/28/18 Sheet G5.5 a a E' a o EE NOTES: FOR PVC -- USE SDR 35 FOR 10 FT. OR LESS. USE SDR 26 FOR 10 FT. OR MORE. USE DUCTILE IRON - IF UNDER 3 FT. DEEP OR OVER 18 FT. DEEP. x NO STONES LARGER THAN # 67 STONE SHALL BE USED IN SELECT BACKFILL PVC C900 SDR 18 (200 PSI) OR DUCTILE IRON CL) WITH PROTECTEC L f GRAVITY SEWER - BEDDING DETAIL CLASS C L -4 FORCE MAIN AREFULLY COMPACTED ELECT BACK FILL 1 FT. BOVE TOP OF PIPE #67 STONE kMP IN -12" LIFTS :CAREFULLY COMPACTED SELECT BACK FILL 1 FT. ABOVE TOP OF PIPE HAND TAMP EARTH UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. SEWER BEDDING SCALE: N.T.S. 8 A GATE: 12-16-13 -24"— 18" MAX, THREE COURSES OF GRADE RINGS MAXIMUM STRAIGHT WALL OF M.H. TO BE LOCATED OVER INLET 5' - 0" FOR PIPES OVER 18" 4' - 0" FOR PIPES 16" & SMALLER PRECAST INVERTS ONLY 5" SCH 40 STEEL PIPE WITH EPDXY COATING RUST-OLEUM 9335 ABOVE GRADE 9578 BELOW GRADE - 9373 PRIMER T 60° MESH SCREEN 2" STAINLESS STEEL STAPS O.C. FROM BASE " x 3" S.S. ANCHOR PER STRAP x 2' ETE ANCHOR GENERAL NOTES: (1) 1 ROLL OF MASTIC AND A 6" EXTERNAL JOINT/SEAM WRAP INSTALLED ON EACH MANHOLE SECTION (2) MANHOLE VACUUM TESTING - AFTER EACH MANHOLE IS INSTALLED AND ALL PIPES ARE CONNECTED, BUT BEFORE BACKFILLING, THE MANHOLE SHALL BE VACUUM TESTED. ALL PIPES ENTERING THE MANHOLE SHALL BE PLUGGED AND BRACED, THE CONTRACTOR SHALL FURNISH ALL MATERALS, LABOR AND EQUIPMENT NECESSARY TO PERFORM THE TESTING. A VACUUM OF 10 INCHES OF MERCURY SHALL BE CREATED ON THE INSIDE OF THE MANHOLE, AT THE VACUUM OF 10 INCHES OF MERCURY, THE PUMP SHALL BE STOPPED AND THE TIME SHALL BE MEASURED FOR THE VACUUM TO DROP TO 9 INCHES. FAILURE OF THE TEST SHALL BE ANY AMOUNT OF TIME LESS THAN THE FOLLOWING. 4 FT. DIAMETER MANHOLE = 60 SECONDS 5 FT. DIAMETER MANHOLE = 75 SECONDS 6 FT. DIAMETER MANHOLE = 90 SECONDS 7 FT. DIAMETER MANHOLE = 105 SECONDS 8 FT. DIAMETER MANHOLE = 120 SECONDS 10 FT. DIAMETER MANHOLE = 150 SECONDS UPON TEST FAILURE, THE CONTRACTOR SHALL REPAIR ALL LEAKS AND RETEST THE MANHOLE UNTIL THE TEST HAS PASSED. STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: MANHOLE 10 UNION COUNTY, N,C, DATE: DATE4 THRUST BLOCK DIMENSIONS BASED ON SOIL BEARING CAPACITY OF 2000 P.S.F. AND A WATER TEST PRESSURE OF 150 P.S.I. SIZES OF THRUST BLOCKS MAY BE REVISED BY THE ENGINEER WHERE BEARING CAPACITY OF SOIL VARIES. PROVIDE TAR PAPER JOINT BETWEEN CONCRETE THRUST BLOCK AND PORTION OF PIPE BEING ANCHORED. ALL CONCRETE THRUST BLOCKS SHALL BE 2500 P.S.I. CONCRETE. MAXIMUM VERTICAL DEFLECTION SHALL BE 22 1/2°. JOINTS SHALL REMAIN FREE OF CONCRETE FOR INSPECTION, REPAIR OR REPLACEMENT OF JOINTS, UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: UNION COUNTY, N.C. THRUST BLOCK SPEC F CAT ONS DATAE: 11-17-06 NOTES: MINIMUM COVER IS 36" 2" PVC SDR 21 (200 PSI) 6"-8" PVC SDR 18 12" OR LARGER DIP W NO STONES LARGER THAN # 67 STONE SHALL BE USED IN SELECT BACKFILL UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. TAMP IN 6" - 12" LIFT CAREFULLY COMPACTED SELECT BACK FILL 1 FT. ABOVE TOP OF PIPE HAND TAMP EARTH WiW VU 1 1 UIl ULLL STANDARD DETAIL WATER TRENCH 83I NOTES: ESMT/R/W LINE 4" CLEAN OUT EXTENSION TO BE LOWERED AFTER 1, THE CLEAN-OUT SHALL BE ADJUSTED TO GRADE CONNECTION TO BUILDING PLUMBING AND THE POST REMOVED BY THE PLUMBER UPON CONNECTION TO THE TAP. 4"x4"x8' (MIN) POST TO BE 2. PLUMBER SHALL HAVE THE OPTION TO INSTALL A ONE I REMOVED AFTER CONNECTION PIECE 4" SCH. 40 COMBINATION WYE TO MINIMIZE 24" CONCRETE 1' TRENCH DEPTH OR INSTALL THE SEWER SERVICE MIN I MIN TO BUILDING PLUMBING LATERAL FROM THE 4" STUB OUT. PROTECTOR I (SEE NOTE 1) RING I I FINISHED GRADE 3. ALL CONSTRUCTION BY THE PLUMBER, EITHER OPTION 1 1 I OR OPTION 2, SHALL BE INSPECTED AND APPROVED BY UNION COUNTY PLUMBING INSPECTOR UNDER A %�� \�/�j,•/�. //i ��\//�\! VALID PLUMBING PERMIT. 4. CONTRACTOR OR UNION COUNTY PUBLIC WORKS 4" PVC FEMALE PERSONNEL MAY ADJUST SERVICE LATERAL ELEVATION ADAPTOR W/SHC. 3.0 WITH FITTINGS IF ADEQUATE GRADE EXISTS. 40 PLUG MIN 5. LATERAL CONNECTIONS TO MANHOLES MUST BE CORED AND BOOT INSTALLED. 4" SCH. 40 PVC 4" SCH. 4D - 1/8 BEND OPTIONAL 4" SCH. 40 COMBINATION SOLVENT WELD CONNECTION (TYP) WYE TO BE INSTALLED _u_ - --i BY BUILDER'S PLUMBER. �i TO BUILDING 4" SCH. 40 PVC NIPPLE. IF ADEQUATE GRADE EXISTS BY PLUMBER LENGTH VARIES DEPENDING ON TO BUILDING'S FLOOR OPTION 2 DEPTH OF SEWER MAIN TO ELEVATION (SEE NOTE 2) TO BUILDING (SEE NOTE 3) MINIMIZE ADDITIONAL BENDS. BY PLUMBER 4" SCH. 40 COMBINATION WYE OPTION 1 L� DISTANCE VARIES (SEE NOTE 3) SDR 35 PVC 8x8x4 WYE----__� INSTALL ROTATED 45° FROM THE SPRING LINE 1% MIN. SLOPE 12' SPRING LINE - 45° GRAVITY SEWER MAIN (SEE SPECIFICATIONS) 4" SCH. 40 PVC CAP ON 4" STUB OUT UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SEWER ATERA SCALE: N.T.S. UNION COUNTY, N.C. DATE: 2/19-14 EXISTING WATER MAIN THRUST BLOCKING DIP TAPPING SLEEVE ___v_ � VALVE ENCASEMENT CD CD OPTION "A" TIE IN - DUCTILE IRON DETAIL NOTE: OPTION "A" OR "B" WILL BE REQUIRED, DEPENDING ON THE AMOUNT OF SPACE AVAILABLE, TO BE FIELD VERIFIED EXISTI WATER M/ RESTRAINT JOIN' PIPE FROM VALVI TO 54' PAST CASIN, DIP _/ DIP WATER MA THRUST BLOCKING APPING SLEEVE VALVE 54' C) ENCASEMENT OPTION "B" TIE IN - DI, RESTRAINT JOINT DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. T A P P G SLEEVE DATE: 11-17-06 ® 1 1/4' RAISED LETTERING LJ (RECESSED FLUSH) y ANCHORAGE SCHEDULE ® TAPPING PLUG m w w (2) 111/49 BEND 22 1/22 BEND 452 BEND 900- BEND TEE O TEST PRESSURE PIPE SIZE L H L H L H L H L H (P.S.I) 6„ 1'3" TO" 2'3" 1'0" 2'6" 1'6" 2'9" 1'6" 2'0" 1'6" 200 1'6" 13" 2'3" 1'6" 3'0" 1'6" 4'0" 1'6" 3'0" 1'6" 300 m 1'6" 1'6" 2'6" 119" 3'0" 2'0" 3'9" 2'0" 2'6" 2'0" 200 8„ 2'0" 1'6" 3'0" 2'0" 3'9" 2'3" 4'6" 2'6" 3'6" 2'3" 300 2'6" 1'9" 4'0" 2'3" 4'3" 3'0" 5'0" 3'3" 4'0" 3'0" 200 12 3'6" 2'0" 59" 2'6" 6'0" 1 3'3" 7'0" 316" 510" 3'6" 300 3'0" TO" 4'0" 3'0" 4'6" 3'9" 6'0" 3'9" 4'6" 3'6" 200 14" 4'0" 2'6" 53" 3'6" 6'0" 4'3" 6'6" 5'0" 510" 5'0" 300 16" 3'0" 2'9" 4'6" 3'6" 5,0" 4'6" 7'0" 4'3" 5,0" 4'0" 200 4'0" 3'0" 6'3" 3'9" 6'5" 5'3" 8'0" 5'3" 7'6" 4'0" 300 THRUST BLOCK DIMENSIONS BASED ON SOIL BEARING CAPACITY OF 2000 P.S.F. AND A WATER TEST PRESSURE OF 150 P.S.I. SIZES OF THRUST BLOCKS MAY BE REVISED BY THE ENGINEER WHERE BEARING CAPACITY OF SOIL VARIES. PROVIDE TAR PAPER JOINT BETWEEN CONCRETE THRUST BLOCK AND PORTION OF PIPE BEING ANCHORED. ALL CONCRETE THRUST BLOCKS SHALL BE 2500 P.S.I. CONCRETE. MAXIMUM VERTICAL DEFLECTION SHALL BE 22 1/2°. JOINTS SHALL REMAIN FREE OF CONCRETE FOR INSPECTION, REPAIR OR REPLACEMENT OF JOINTS, UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: UNION COUNTY, N.C. THRUST BLOCK SPEC F CAT ONS DATAE: 11-17-06 NOTES: MINIMUM COVER IS 36" 2" PVC SDR 21 (200 PSI) 6"-8" PVC SDR 18 12" OR LARGER DIP W NO STONES LARGER THAN # 67 STONE SHALL BE USED IN SELECT BACKFILL UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. TAMP IN 6" - 12" LIFT CAREFULLY COMPACTED SELECT BACK FILL 1 FT. ABOVE TOP OF PIPE HAND TAMP EARTH WiW VU 1 1 UIl ULLL STANDARD DETAIL WATER TRENCH 83I NOTES: ESMT/R/W LINE 4" CLEAN OUT EXTENSION TO BE LOWERED AFTER 1, THE CLEAN-OUT SHALL BE ADJUSTED TO GRADE CONNECTION TO BUILDING PLUMBING AND THE POST REMOVED BY THE PLUMBER UPON CONNECTION TO THE TAP. 4"x4"x8' (MIN) POST TO BE 2. PLUMBER SHALL HAVE THE OPTION TO INSTALL A ONE I REMOVED AFTER CONNECTION PIECE 4" SCH. 40 COMBINATION WYE TO MINIMIZE 24" CONCRETE 1' TRENCH DEPTH OR INSTALL THE SEWER SERVICE MIN I MIN TO BUILDING PLUMBING LATERAL FROM THE 4" STUB OUT. PROTECTOR I (SEE NOTE 1) RING I I FINISHED GRADE 3. ALL CONSTRUCTION BY THE PLUMBER, EITHER OPTION 1 1 I OR OPTION 2, SHALL BE INSPECTED AND APPROVED BY UNION COUNTY PLUMBING INSPECTOR UNDER A %�� \�/�j,•/�. //i ��\//�\! VALID PLUMBING PERMIT. 4. CONTRACTOR OR UNION COUNTY PUBLIC WORKS 4" PVC FEMALE PERSONNEL MAY ADJUST SERVICE LATERAL ELEVATION ADAPTOR W/SHC. 3.0 WITH FITTINGS IF ADEQUATE GRADE EXISTS. 40 PLUG MIN 5. LATERAL CONNECTIONS TO MANHOLES MUST BE CORED AND BOOT INSTALLED. 4" SCH. 40 PVC 4" SCH. 4D - 1/8 BEND OPTIONAL 4" SCH. 40 COMBINATION SOLVENT WELD CONNECTION (TYP) WYE TO BE INSTALLED _u_ - --i BY BUILDER'S PLUMBER. �i TO BUILDING 4" SCH. 40 PVC NIPPLE. IF ADEQUATE GRADE EXISTS BY PLUMBER LENGTH VARIES DEPENDING ON TO BUILDING'S FLOOR OPTION 2 DEPTH OF SEWER MAIN TO ELEVATION (SEE NOTE 2) TO BUILDING (SEE NOTE 3) MINIMIZE ADDITIONAL BENDS. BY PLUMBER 4" SCH. 40 COMBINATION WYE OPTION 1 L� DISTANCE VARIES (SEE NOTE 3) SDR 35 PVC 8x8x4 WYE----__� INSTALL ROTATED 45° FROM THE SPRING LINE 1% MIN. SLOPE 12' SPRING LINE - 45° GRAVITY SEWER MAIN (SEE SPECIFICATIONS) 4" SCH. 40 PVC CAP ON 4" STUB OUT UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SEWER ATERA SCALE: N.T.S. UNION COUNTY, N.C. DATE: 2/19-14 EXISTING WATER MAIN THRUST BLOCKING DIP TAPPING SLEEVE ___v_ � VALVE ENCASEMENT CD CD OPTION "A" TIE IN - DUCTILE IRON DETAIL NOTE: OPTION "A" OR "B" WILL BE REQUIRED, DEPENDING ON THE AMOUNT OF SPACE AVAILABLE, TO BE FIELD VERIFIED EXISTI WATER M/ RESTRAINT JOIN' PIPE FROM VALVI TO 54' PAST CASIN, DIP _/ DIP WATER MA THRUST BLOCKING APPING SLEEVE VALVE 54' C) ENCASEMENT OPTION "B" TIE IN - DI, RESTRAINT JOINT DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. T A P P G SLEEVE DATE: 11-17-06 ® 1 1/4' RAISED LETTERING LJ (RECESSED FLUSH) y (2) 1' (25mm) DIA, HOLES ® TAPPING PLUG m w w (2) m I O(4) m 1' (25r r1) DIA O f+ O I U HOLES ON 29 3/4' O Q S fiy FWtN (756mrm) BOLT CIRCLE, LU w�J� FO SDA PO R�\S� v z Ua5 � 00)) - a <D 13 i 0 BOTTOM VIEW 3/4' (19mm) LETTERS (RECESSED FLUSH) NOTES: 1. ALL CASTINGS TO BE FREE FROM SAND HOLES. NO PLUGGING ALLOWED. 2. MACHINE ALL CONTACT SURFACES BETWEEN RING AND COVER. 3, PROVIDE TWO VENT HOLES IN COVER, 1" DIA. TAPERED TO 1-1/8" ON REVERSE SIDE. 4, MINIMUM WEIGHTS: COVER - 120 LBS. RING - 190 LBS. 5. ALL MANHOLE RINGS OUT OF ROAD RIGHT OF WAY SHALL BE BOLTED INTO MANHOLE WITH 5/8" DIAMETER KWIK BOLT STUD ANCHOR SYSTEM. HILTI BRAND OR APPROVED EQUAL. 2' -1 1/4" 1' - 113/4" 1' - 111/2" T 2 1/8" 3 3/4" + 7 1/2" 3 1' 10 44 3 4" 4 3/8" I-- 2' - 0 1/2" 4 3/8" 2'-91/4" (U.S. FOUNDRY - 669, VULCAN - 1384 OR EQUAL} UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL RING & COVER SCALE UNION COUNTY, N.C. N,T,S. DATE: 9-9-11 UNDISTURBED EARTH 12" L CONCRETE71. i r DITCH BANKS PLAN 45° BENDS ALSO 90 22 1/2°. 11112' DITCH L BANKS MAX 45° CONCRETE I UNDISTURBED EARTH DITCH BANKS DITCH BANK CONTRACTOR SHALL USE TIE RODS TO SHIM AS NECESSARY H CONCRETE SECURE VERTICAL BENDS -,DITCH BOTTOM DITCH \ \ BOTTOM H12 .V UNDISTURBED EARTH MIN. 11/2 CU. YD UNDISTURBED EARTH J OF CONCRETE ELEVATION AT FITTINGS VERTICAL BEND UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. THRUST BLOCK DATE: 16 11-17-06 METER EXISTING WATERMAIN RPZ 2" GATE VALVE TAPPING SLEEVE TAPPING VALVE J REDUCER TO 2" CONNECTOR LINE ,0 GENERAL NOTES; z 0 rn O LJ Lo I SLEEVE -LONG PATTERN WV TAPPING PLUG m w w RESTRAINT VALVE m I I (1) INSTALL CONNECTOR LINE FROM TAPPING VALVE TO NEW MAIN FOR FILLING, TESTING AND STERILIZING NEW MAIN. (2) CONNECTOR LINE TO BE ASSEMBLED WITH RPZ AND METER BY CONTRACTOR AND TO BE OPERATED AND INDEPENDENT OF EXISTING MAIN, 131 FINAL CONNECTION TO EXISTING MAIN TO BE MADE ONLY AFTER TOTAL PROJECT IS ACCEPTED BY UNION COUNTY PUBLIC WORKS. (4) VALVES ON EXISTING SYSTEM TO BE OPERATED BY UCPW FORCES ONLY. 15) ONLY ONE CONNECTION WILL BE ALLOWED BETWEEN THE EXISTING SYSTEM AND THE NEW CONSTRUCTION UNTIL TESTING AND DISINFECTION IS COMPLETE. -- -- 1--i 54 LF RESTRAINT JT. NEW WATERMAIN STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: UNION COUNTY, N.C. DRECT TAP JUMPER CONN, - SHORTSIDE DATE: 2 5 A 9-2-10 w rn O rn O O O M � WV Lo � O 0) m m � M � � z Z -� m J— rL DG U 0 Q ^ W LU o °' v z Ua5 � 00)) - a <D �QNN �z� I— cv m J Zca w Ww o a3 O N W w 2 rn m � m >cc m o m m � � z r^ Li = m J 0 0 z 14 5 _ GINEE�, 5/28/18 Shee[ C-5.6 2 rn � >cc m o m W � � z r^ Li = m J Q W Q u o O Y w N I— cv m J o w 0 W � m Q 0 w z W Q) U o m 14 5 _ GINEE�, 5/28/18 Shee[ C-5.6 3 rn 0 �I F7 0 Li oM 0 1. MAXIMUM GROUND SLOPE OF 5' TO 1' IN ANY r^ uo co 0 DIRECTION INSIDE WATER/SEWER EASEMENTS. J m � M 2. SLOPE GREATER THAN 5' TO 1' MUST HAVE WATER MAIN CROSSING m co co PRI❑R APPROVAL FROM UNI❑N COUNTY PUBLIC PRIVATE I I I I RIVATE 0 UNDER STORM DRAIN DETAIL Y Lu 5, U� a-) SERVICE m Q N N SERVICE 0 W 0 ONLY APPLICABLE IF u- Z N UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. STANDARD DETAIL 32 LINE MAXIMUM SLOPE ACROSS WATER/ SEWER EASEMENT 5:1 SLOPE SN T.S LINE m M a MAXIMUM DEPTH OF BURY W Z S2 � co W o N FOR WATER MAIN IS LESS THAN 6' AT CROSSING, 3/4" IRRIGATION 0 O 3/4" DOMESTIC -7F,I METER METER ��� li' -III ��I�� I I III -III III � IIII— III III ' I' ❑ FITTINGS PROPOSED 6,0' DEPTH (MAX.) GRADE 3.0' COVER (MIN.) STORM DRAIN NOTES:3 1. METERS WILL NOT BE SET IF WATER METER BOXES, SEWER CLEAN -OUTS, VALVE BOXES /4 COMPRESSION TEE 45 DEGREE 45 DEGREE BENDS BENDS OR THEIR APPURTENANCES ARE DAMAGED OR I_ .I 12" (MIN.) IMPROPERLY POSITIONED, 3/4" COPPER SERVICE TO 54' RESTRAINT JOIN DIP 54' RESTRAINT J❑INT DIP 2. WATER METERS ARE TO BE INSTALLED PERPENDICULAR TO THE ROAD AND WITHIN THE ROAD RIGHT-OF-WAY OR WITHIN THE LIMITS OF A PROPOSED UTILITY EASEMENT, IRRIGATI❑N 3/4" WATER METER SERVICE TO WATERMAIN RESTRAINT JOINT DIP WATER MAIN I I - - 20' RESTRAINT J❑INT DIP RESTRAINT JOINT DIP 3, IF THE IRRIGATI❑N LINE IS TO BE UTILIZED AND A METER SET,THE APPROPRIATE REDUCED PRESSURE ASSEMBLY SHALL BE INSTALLED BY THE CONTRACTOR PER UCPW DETAIL 24A, UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: SCALE: UNION COUNTY, N.C. IRRIGATION AND DOMESTIC DUAL METER TAP N.T.S.30UNION COUNTY, N.C. WATER MAIN UNDER STORM DRAIN CROSSING N.T.S. 31 DATE: DATE: 07-18-16 08-31-16 3 rn 0 NOTE: 0 Li oM 0 1. MAXIMUM GROUND SLOPE OF 5' TO 1' IN ANY r^ uo co 0 DIRECTION INSIDE WATER/SEWER EASEMENTS. J m � M 2. SLOPE GREATER THAN 5' TO 1' MUST HAVE �o m co co PRI❑R APPROVAL FROM UNI❑N COUNTY PUBLIC � � U Q WORKS, 0 FINISHED GRADE Y Lu 5, U� a-) 1, m Q N N VARIABLE R/W 0 W 0 WATER OR D--�SEWER MAIN u- Z N UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. STANDARD DETAIL 32 MAXIMUM SLOPE ACROSS WATER/ SEWER EASEMENT 5:1 SLOPE SN T.S DATE: 03/02/18 m 3 W rn 0 0 Li oM 0 m r^ uo co 0 z m J m � M �o m co co N � � U Q C 0 z Y Lu U� a-) ami m Q N N J 0 W 0 u- Z N Z m-'000 W uj o m M a W Z S2 � co W o N W m m r^ W z m J m Q 0 W M 0 z Y J W � CL z W —� U U Z cl- z z Lu oLu Qw ca J J J uj W w z Q — Q� Q L z U LLJ U Ouj Q z OD J J m Sheet C-5.7 m m r^ W z m J Q W M Q L � Y o N M m J 0 W 0 W o m Q W Z S2 co W N o Sheet C-5.7 3 V 0 3 T E V X I. MISCELLANEOUS V. PAVING AND GRADING NPDES NOTE: A. CURRENT EDITIONS OF THE NORTH CAROLINA DOT ROADWAY STANDARD DRAWINGS AND A. ALL DELETERIOUS SUBSURFACE MATERIAL (I.E. MUCK, PEAT, BURIED DEBRIS) IS TO BE REGULATIONS ADOPTED BY THE US ENVIRONMENTAL PROTECTION AGENCY (US EPA) AND BY PAVED AREAS. WATER SHALL NOT BE ALLOWED TO ACCUMULATE SPECIFICATIONS MANUAL SHALL BE CONSIDERED PART OF THESE PLANS. EXCAVATED IN ACCORDANCE WITH THESE PLANS OR AS DIRECTED BY THE OWNER, THE THE NORTH CAROLINA DIVISION OF WATER QUALITY REQUIRE THAT A NATURAL POLLUTANT B. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE PERMIT AND INSPECTION OWNER'S ENGINEER, OR OWNER'S SOIL TESTING COMPANY. DELETERIOUS MATERIAL IS TO DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT BE OBTAINED FOR STORMWATER N. GENERAL ROCK EXCAVATION: ROCK SHALL BE DEFINED AS ANY REQUIREMENTS SPECIFIED BY THE VARIOUS GOVERNMENTAL AGENCIES THE ENGINEER, BE STOCKPILED OR REMOVED FROM THE SITE AS DIRECTED BY THE OWNER OR THE DISCHARGES FROM CONSTRUCTION ACTIVITIES WITH LAND DISTURBANCE OF 1 ACRE OR MORE. CANNOT BE EXCAVATED WITH A SINGLE - TOOTH RIPPER DRAWN AND THE ARCHITECT. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR OWNER'S ENGINEER. EXCAVATED AREAS TO BE BACKFILLED WITH APPROVED MATERIALS c W TO CONSTRUCTION, AND SHALL SCHEDULE ANY NECESSARY INSPECTIONS ACCORDING TO AND COMPACTED AS SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR CONTRACTOR SHALL CHECK EROSION CONTROL MEASURES WEEKLY AND/OR AFTER A 1/2" ui AGENCY INSTRUCTIONS. ACQUIRING ANY PERMITS THAT ARE NECESSARY FOR REMOVING DELETERIOUS MATERIAL OR MORE RAIN. CONTRACTOR SHALL KEEP RECORDS OF EVERY INSPECTION. C. ALL SPECIFICATIONS AND DOCUMENTS REFERRED TO IN THESE PLANS SHALL BE OF THE FROM THE SITE. 3 z LATEST REVISION. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXCAVATIONS AGAINST 0 (i D. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE COLLAPSE AND WILL PROVIDE BRACING, SHEETING OR SHORING AS NECESSARY. 10 m 00 c4 VARIOUS GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THE WORK. DEWATERING METHODS SHALL BE USED AS REQUIRED TO KEEP TRENCHES DRY WHILE EROSION CONTROL NOTES: E. WORK PERFORMED UNDER THIS CONTRACT SHALL INTERFACE SMOOTHLY WITH OTHERPIPE AND APPURTENANCES ARE BEING PLACED. 1. CONTRACTORSHALL STABILIZE EXPOSED GROUND AS SOON AS INDIVIDUAL AREAS S ARE Lu WORK BEING PERFORMED ON SITE BY OTHER CONTRACTORS AND UTILITY COMPANIES. THE C. ALL NECESSARY FILL AND EMBANKMENT THAT IS PLACED DURING CONSTRUCTION SHALL COMPLETED. CONTRACTOR SHALL COORDINATE AND SCHEDULE HIS ACTIVITIES WHERE NECESSARY CONSIST OF MATERIAL SPECIFIED BY THE OWNER'S SOIL TESTING COMPANY OR ENGINEER WITH OTHER CONTRACTORS AND UTILITY COMPANIES. AND BE PLACED AND COMPACTED ACCORDING TO THESE PLANS OR THE REFERENCED 2. CONTRACTOR SHALL NOT REMOVE ANY BASIN UNTIL ALL SEDIMENT -PRODUCING AREAS F. THE WATER AND SANITARY SEWER FACILITIES ARE SUBJECT TO REVIEW BY UNION SOILS REPORT. UPSTREAM HAVE BEEN PERMANENTLY STABILIZED AND REMOVAL IS APPROVED BY COUNTY PUBLIC WORKS AND APPROVAL. STORM DRAINAGE FACILITIES ARE SUBJECT TO D. PROPOSED SPOT ELEVATIONS REPRESENT FINISHED PAVEMENT OR GROUND SURFACE EROSION CONTROL COORDINATOR. THE REVIEW AND APPROVAL OF THE THE VILLAGE OF WESLEY CHAPEL AND NCDOT AND GRADE UNLESS OTHERWISE NOTED ON DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN THE REQUIRED E. CONTRACTOR SHALL PROVIDE EROSION CONTROL AND SEDIMENTATION BARRIER (SILT 3. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS PERMITS TO PERFORM WORK IN THE PUBLIC RIGHT-OF-WAY. NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY G. GRADING OFF SITE WILL REQUIRE A LETTER OF PERMISSION FROM THE OWNER PRIOR TO FENCE OR OTHER MEASURES) TO PREVENT SILTATION OF ADJACENT PROPERTY, STREETS, WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE SHOWN ON ANY LAND DISTURBING ACTIVITIES. STORM SEWERS AND WATERWAYS. THE PLAN. ALL GRADED SLOPES MUST BE SEEDED AND MULCHED WITHIN 14 CALENDAR H. ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION OF THE VILLAGE OF F. IF WIND EROSION BECOMES SIGNIFICANT DURING CONSTRUCTION, THE CONTRACTOR SHALL DAYS (7 CALENDAR DAYS FOR SLOPES STEEPER THAN 3:1). WESLEY CHAPEL, UCPW, AND NCDOT STANDARDS. STABILIZE THE AFFECTED AREA USING SPRINKLING, IRRIGATION OR OTHER ACCEPTABLE I. THE VILLAGE OF WESLEY CHAPEL RESERVES THE RIGHT TO INSPECT ALL CONSTRUCTION METHODS. 4. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY WITHIN THE PUBLIC RIGHT-OF-WAY, PUBLIC STORM DRAIN EASEMENTS, DETENTION AND G. THE CONTRACTOR WILL STABILIZE BY SEED AND MULCH, SOD OR OTHER APPROVED LOCAL AUTHORITY. WATER QUALITY BMP'S. THE VILLAGE OF WESLEY CHAPEL HAS THE ABILITY TO APPROVE MATERIALS AS REQUIRED BY ANY DISTURBED AREAS WITHIN ONE WEEK FOLLOWING OR REJECT ANY WORK COMPLETED OR ONGOING BY THE CONTRACTOR AT THE CONSTRUCTION OF THE UTILITY SYSTEMS AND PAVEMENT AREAS. CONTRACTOR SHALL 5. NO SLOPES SHALL EXCEED 2:1. FILL SLOPES GREATER THAN 10' REQUIRE ADEQUATE DEVELOPER'S EXPENSE. MAINTAIN SUCH AREAS UNTIL FINAL ACCEPTANCE BY OWNER. TERRACING. H. ENGINEERED FILL MATERIAL SHALL NOT CONTAIN ROCKS OR HARD LUMPS GREATER THAN II. SAFETY 3 INCHES IN MAXIMUM DIMENSIONS AND SHALL BE FREE OF VEGETATION, ORGANIC 6. GROUNDCOVER ON EXPOSED SLOPES SHOULD BE COMPLETED WITHIN 14 CALENDAR DAYS. A. DURING THE CONSTRUCTION AND MAINTENANCE OF THIS PROJECT, ALL SAFETY MATTER, DEBRIS, RUBBLE, AND OTHER UNSUITABLE MATERIALS. SHALL BE REGULATIONS SHALL BE ENFORCED. THE CONTRACTOR OR HIS REPRESENTATIVE NON -EXPANSIVE MATERIALS I. IMPORTED SOILS FOR USE AS ENGINEERED FILL AND SHALL NOT CONTAIN ROCKS OR 7. ALL SILT FENCE SHALL HAVE WIRE AND WASHED STONE. SHALL BE RESPONSIBLE FOR THE CONTROL AND SAFETY OF THE TRAVELING PUBLIC HARD LUMPS GREATER THAN 3 INCHES IN MAXIMUM DIMENSIONS AND SHALL BE FREE OF AND THE SAFETY OF HIS PERSONNEL. VEGETATION, ORGANIC MATTER, DEBRIS, RUBBLE, AND OTHER UNSUITABLE MATERIALS. 8 A FILTER BERM SHALL BE PLACED TEMPORALLY AT THE END OF ALL FES UNTIL RIP RAP B. THE CONTRACTOR'S MAINTENANCE OF TRAFFIC PLAN MUST BE SUBMITTED AND J. AGGREGATE BASE MATERIAL SHALL MEET THE FOLLOWING GRADATION REQUIREMENTS. APRONS ARE INSTALLED. APPROVED BY THE COUNTY AND EAGLE ENGINEERING PRIOR TO BEGINNING ANY 9. ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FOR THE CONSTRUCTION ACTIVITIES. SIEVE SIZE (PER ASTM D422) % PASSING BY WEIGHT ZONING ADMINISTRATOR. C. LABOR SAFETY REGULATIONS SHALL CONFORM TO THE PROVISIONS SET FORTH BY 1 INCH 100 OSHA IN THE FEDERAL REGISTER OF THE DEPARTMENT OF TRANSPORTATION. 3/4" 90 - 100 10. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF D. CONTRACTOR SHALL PROVIDE AND MAINTAIN HIS OWN SAFETY EQUIPMENT IN 200 THE CITY/COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. ACCORDANCE WITH HIS HEALTH & SAFETY PROGRAM AND ALL OTHER APPLICABLE NO. 05- 855 LEGAL AND HEALTH AND SAFETY REQUIREMENTS. THE CONTRACTOR IS ALSO K. ALL AREAS TO RECEIVE FILL, AND AREAS OF STRUCTURES AND PAVEMENTS, SHALL BE 11. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A RESPONSIBLE FOR PROVIDING ITS EMPLOYEES AND SUB CONTRACTORS WITH STRIPPED OF VEGETATION, ORGANIC MATTER, DEBRIS, RUBBLE, AND OTHER UNSUITABLE VIOLATION OF NC LAW AND IS SUBJECT TO A FINE. ADEQUATE INFORMATION AND TRAINING TO ENSURE THAT ALL EMPLOYEES AND SUB MATERIALS. STRIPPED SOILS SHALL NOT BE USED IN ENGINEERED FILL, BUT MAY BE CONTRACTORS AND SUB CONTRACTOR'S EMPLOYEES COMPLY WITH ALL APPLICABLE USED IN LANDSCAPE AREAS. ENGINEERED FILL MATERIAL SHALL BE COMPACTED TO AT 12. A GRADING PLAN MUST BE SUBMITTED FOR ANY LOT GRADING THAT WAS NOT REQUIREMENTS. CONTRACTOR SHALL REMAIN IN COMPLIANCE WITH ALL OCCUPATION LEAST THE FOLLOWING PREVIOUSLY APPROVED. SAFETY AND HEALTH REGULATIONS AS WELL AS THE ENVIRONMENTAL PROTECTION 13. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. LAWS. THE FOLLOWING IS NOT TO BE PERCEIVED AS THE ENTIRE SAFETY PROGRAM * PERCENTAGES OF MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT, PER ASTM WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED BUT JUST BASIC REQUIREMENTS. D-698 (STANDARD PROCTOR): FROM AFFECTED PROPERTY OWNERS. E. ALL EXCAVATIONS BY THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF LABOR'S OCCUPATIONAL SAFETY AND HEALTH ENGINEERED FILL MINIMUM % MOISTURE CONTENT 14. ALL STD. NUMBERS REFER TO THE NCDEQ STANDARDS MANUAL UNLESS OTHERWISE ADMINISTRATION RULES AND REGULATIONS. PARTICULAR ATTENTION MUST BE PAID MATERIAL COMPACTION RANGE NOTED. NATIVE SOIL 92% OPTIMUM TO OPTIMUM PLUS 3% TO THE CONSTRUCTION STANDARDS FOR EXCAVATIONS, 29 CFR PART 1926, SUBPART P. ENGINEERED FILL UNDER STRUCTURES 98% OPTIMUM TO OPTIMUM PLUS 3% 15. STEEL POST WITH WIRE FENCE BACKING SHOULD BE USED INSTEAD OF WOODEN POST, F. THE MINIMUM STANDARDS AS SET FORTH IN THE CURRENT EDITION OF "MANUAL ON AND BEHIND RETAINING WALLS BURIED OR DRIVEN TO A DEPTH OF 18" IN THE GROUND. PREFABRICATED SILT FENCE IS NOT ACCEPTABLE ON THIS PROJECT. UNIFORM TRAFFIC CONTROL DEVICES" (U.S. DOT) SHALL BE FOLLOWED IN THE DESIGN APPLICATION, INSTALLATION, MAINTENANCE AND REMOVAL OF ALL TRAFFIC ENGINEERED FILL UNDER 100% OPTIMUM PLUS OR MINUS 2% 16. SEDIMENT TRAP AND BASINS SLOPES SHALL BE SEEDED IMMEDIATE AFTER CONSTRUCTION CONTROL DEVICES, WARNING DEVICES AND BARRIERS NECESSARY TO PROTECT THE PAVEMENT AREAS TO PROMOTE STABLE SLOPES AS SOON AS POSSIBLE. PUBLIC AND WORKMEN FROM HAZARDS WITHIN THE PROJECT LIMITS. FILL IN LANDSCAPE AREAS 92% 2 TO 5% ABOVE OPTIMUM G. ALL TRAFFIC CONTROL MARKINGS AND DEVICES SHALL CONFORM TO THE 17. WHERE TEMPORARY DIVERSIONS ENTER SEDIMENT TRAPS AND BASINS, TEMPORARY SLOPE PROVISIONS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES AGGREGATE BASE MATERIAL OR IMPORTED GRANULAR SOIL IN BUILDING AND PAVED AREAS DRAINS MAY BE NECESSARY BASED ON FIELD CONDITIONS. PREPARED BY THE U.S. DEPARTMENT OF TRANSPORTATION FEDERAL HIGHWAY SHALL BE COMPACTED TO AT LEAST THE FOLLOWING PERCENTAGES OF MAXIMUM DRY ADMINISTRATION. DENSITY AND OPTIMUM MOISTURE CONTENT, PER ASTM D-698 MODIFIED OR AASHTO MAINTENANCE PLAN: H. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY AND EQUIVALENT. 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND ENFORCE ALL APPLICABLE SAFETY REGULATIONS. THE ABOVE INFORMATION HAS OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS BEEN PROVIDED FOR THE CONTRACTOR'S INFORMATION ONLY AND DOES NOT IMPLY MATERIAL COMPACTION RANGE THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN AGGREGATE BASE MATERIAL OR 100% OPTIMUM PLUS OR MINUS 2% ALL PRACTICES AS DESIGNATED. OR ENFORCE SAFETY THAT THE OWNER OR ENGINEER WILL INSPECT AND/OR IMPORTED GRANULAR SOIL IN BUILDING REGULATIONS. AND PAVEMENT AREAS 2. THE SEDIMENT BASIN WILL BE CLEANED OUT WHEN THE LEVEL OF SEDIMENT REACHES 2.0 I. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN AREAS OF BURIED FT. BELOW THE TOP OF THE RISER. GRAVEL WILL BE CLEANED OR REPLACED WHEN THE UTILITIES AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE TO THE UTILITY SEDIMENT POOL NO LONGER DRAINS PROPERLY. COMPANIES PRIOR TO CONSTRUCTION TO OBTAIN FIELD LOCATIONS OF EXISTING L. IF SUB GRADE SOILS EXHIBIT PUMPING DURING COMPACTION THE AREA SHALL BE UNDERGROUND UTILITIES. ALLOWED TO DRY UNTIL THE SOILS BECOME WORKABLE WITHOUT PUMPING. THE 3. SEDIMENT WILL BE REMOVED FROM THE SEDIMENT TRAP AND BLOCK AND GRAVEL INLET J. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING MOISTURE CONTENT OF THE SOILS SHALL BE ADJUSTED TO PREVENT PUMPING. PROTECTION DEVICE WHEN STORAGE CAPACITY HAD BEEN APPROXIMATELY 50% FILLED. FACILITIES, ABOVE OR BELOW GROUND, THAT MAY OCCUR AS A RESULT OF THE M. EXPOSURE TO THE ENVIRONMENT MAY REDUCE THE STRENGTH OF SOILS IN FOOTING, GRAVEL WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS WORK PERFORMED BY THE CONTRACTOR CALLED FOR IN THIS CONTRACT. FLOOR SLAB, AND PAVED AREAS. IF THIS OCCURS, THE SOFTENED SOILS SHALL BE PROPERLY. K. ALL UNDERGROUND UTILITIES MUST BE IN PLACE AND TESTED OR INSPECTED PRIOR REMOVED AND REWORKED IMMEDIATELY PRIOR TO CONCRETE PLACEMENT. IF RAINFALL IS R EXPECTED AT A TIME WHEN BEARING SOILS IN FOOTING AREAS ARE EXPOSED, A 2 TO 4 4. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES TO BASE AND PAVEMENT CONSTRUCTION. T T ABOUT 0 5 FT DEEP AT THE FENCE THE SEDIMENT FENCE WILL BE REPAIRED AS C. STRUCTURAL PLANS HAVE NOT BEEN RECEIVED BY EEI. TRACTOR HAVING A MINIMUM DRAW BAR PULL RATED AT NOT LESS THAN 56,000 G.S. 113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO D. ELECTRICAL, MECHANICAL, AND FIRE SAFETY PLANS HAVE NOT BEEN RECEIVED BY POUNDS (CATERPILLAR D8K OR EQUIVALENT). THE VOLUME OF ROCK EXCAVATION SHALL GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR BE DETERMINED BY A LICENSED SURVEYOR BY THE AVERAGE END AREA METHOD. THE EEI. CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCALED PLAN WITH SUFFICIENT OTHER ADEQUATE EROSION -CONTROL DEVISES OR STRUCTURES. IN ANY EVENT, E. BOUNDARY SURVEY & TOPOGRAPHIC SURVEY PREPARED BY EAGLE ENGINEERING SLOPES LEFT EXPOSED SHALL WITHIN CALENDAR DAYS OF COMPLETION OF ANY ' ELEVATION POINTS TO ACCURATELY DEFINE THE VOLUME OF ROCK EXCAVATED. THE 14 INC. PHASE OF GRADING, BE PLANTED OR OTHERWISE BE PROVIDED WITH TEMPORARY OR DEPTH OF ROCK SHALL BE DEFINED AS FROM TOP OF ROCK TO THE CONTRACT F. ALL POINTS AND MONUMENTS SHALL BE SURVEYED UPON MOBILIZATION TO VERIFY SPECIFIED ELEVATION FOR EXCAVATION. CONTRACTOR SHALL BE COMPENSATED FOR ROCK PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN THEIR ACCURACY. ANY DISCREPANCIES DISCOVERED MUST BE BROUGHT TO THE EXCAVATION AS DEFINED HEREIN IN ACCORDANCE WITH CONTRACT UNIT PRICES. EROSION. ATTENTION OF THE ENGINEER IN WRITING. G. MONUMENTS AND OTHER SURVEY CONTROL POINTS SHALL BE PROTECTED FROM VI. DRAINAGE: G.S. 113A-57(3), PROVISIONS FOR A PERMANENT GROUND COVER SUFFICIENT TO DAMAGE AND DISTURBANCE. IF ANY CONTROL POINTS ARE DAMAGED OR A. ALL STORM SEWER PIPE SHALL BE REINFORCED CONCRETE PIPE UNLESS OTHERWISE RESTRAIN EROSION MUST BE ACCOMPLISHED WITHIN 15 WORKING DAYS OR 90 DISTURBED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE NOTED ON PLANS. ALL DRAINAGE STRUCTURES SHALL BE IN ACCORDANCE WITH NCDOT CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT, ENGINEER AND REPLACE THE CONTROL POINTS TO THEIR ORIGINAL CONDITION AT STANDARDS UNLESS OTHERWISE NOTED. WHICHEVER PERIOD IS SHORTER. HIS OWN EXPENSE. B. PIPE LENGTHS SHOWN ARE APPROXIMATE AND TO CENTER OF DRAINAGE STRUCTURE OR H. ALL ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM. TO THE END OF THE PIPE. CONTRACTOR SHALL VERIFY ALL QUANTITIES PRIOR TO TEMPORARY SEEDING REQUIREMENTS PER NCDENR EROSION AND I. LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND SUBMITTAL OF BID. OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY C. ALL DRAINAGE STRUCTURE GRATES AND COVERS SHALL BE AS PER NCDOT STANDARDS THE LOCATIONS, ELEVATIONS AND DIMENSIONS OF ALL EXISTING UTILITIES, UNLESS OTHERWISE NOTED. STRUCTURES AND OTHER FEATURES AFFECTING THIS WORK PRIOR TO CONSTRUCTION. D. ALL STORM DRAINAGE PIPING SHALL BE SUBJECT TO A VISUAL INSPECTION BY THE J. UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL FURNISH OWNER'S OWNER'S ENGINEER PRIOR TO THE PLACEMENT OF BACKFILL. CONTRACTOR TO NOTIFY THE ENGINEER WITH COMPLETE "AS -BUILT" INFORMATION CERTIFIED BY A REGISTERED ENGINEER 48 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. LAND SURVEYOR. THIS "AS -BUILT INFORMATION SHALL BE PRODUCED ON AUTOCAD E. THE CONTRACTOR SHALL MAINTAIN AND PROTECT FROM MUD, DIRT, DEBRIS, ETC. THE VERSION 12, OR LATER, AND UPON COMPLETION, THE CONTRACTOR SHALL STORM DRAINAGE SYSTEM UNTIL FINAL ACCEPTANCE OF THE PROJECT. THE CONTRACTOR FURNISH EAGLE ENGINEERING WITH DISKS OF ALL DRAWINGS, ONE SET OF MAY BE REQUIRED TO RECLEAN PIPES AND INLETS FOR THESE PURPOSES. REPRODUCIBLE MYLARS, AND FIVE SETS OF BLUEPRINTS. THE "AS -BUILT" INFORMATION SHALL CLEARLY AND ACCURATELY REPRESENT ALL CONSTRUCTED ITEMS INCLUDING, BUT NOT LIMITED TO: V 1. ELEVATIONS OF ALL STORM SEWER AND SANITARY SEWER STRUCTURE BOTTOMS, A TOPS AND INVERTS. 2. FIELD MEASURED LENGTHS OF PIPES FOR ALL INSTALLED UTILITIES, CONDUITS, SLEEVES, ETC. 3. LOCATIONS OF ALL STRUCTURES PIPES CONDUITS SLEEVES ETC. B 4. CALCULATED SLOPE OF ALL SANITARY SEWER AND STORM SEWER LINES. 5. HORIZONTAL AND VERTICAL CONTROL OF ALL WATER MAIN FITTINGS AND APPURTENANCES, AND HORIZONTAL AND VERTICAL CONTROL ON THE TOP OF WATER MAINS AT ALL CROSSINGS, AND A MINIMUM OF EVERY 200 LINEAR FEET OF PIPE. 6. HORIZONTAL AND VERTICAL CONTROL OF ALL TOP OF BANKS, TOE OF SLOPES, ALL GRADE BREAKS, BUILDINGS, PONDS, ETC. K. ALL DIMENSIONS SHOWN ON PLAN ARE TO FACE OF BUILDING, EDGE OF PAVEMENT, CENTERLINE OF STRUCTURE, OR END OF PIPE UNLESS NOTED OTHERWISE. C IV. CLEARING/DEMOLITION A. THE CONTRACTOR SHALL CLEAR AND GRUB ONLY THOSE PORTIONS OF THE SITE E NECESSARY FOR CONSTRUCTION. DISTURBED AREAS WILL BE SEEDED, MULCHED, SODDED OR PLANTED WITH OTHER APPROVED LANDSCAPE MATERIAL IMMEDIATELY FOLLOWING CONSTRUCTION. B. THE TOP 6" OF GROUND REMOVED DURING CLEARING AND GRUBBING SHALL BE STOCKPILED AT A SITE DESIGNATED BY THE OWNER OR THE OWNER'S ENGINEER TO BE USED FOR LANDSCAPING PURPOSES, UNLESS OTHERWISE DIRECTED BY THE OWNER OR THE OWNER'S ENGINEER. REMAINING EARTHWORK THAT RESULTS FROM CLEARING AND GRUBBING OR SITE EXCAVATION IS TO BE UTILIZED ON-SITE IF REQUIRED, PROVIDED THAT THE MATERIAL IS DEEMED SUITABLE FOR CONSTRUCTION F BY THE OWNER'S SOILS TESTING COMPANY. EXCESS MATERIAL IS TO BE EITHER STOCKPILED ON THE SITE AS DIRECTED BY THE OWNER OR OWNER'S ENGINEER, OR REMOVED FROM THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ANY PERMITS THAT ARE NECESSARY FOR REMOVING EXCESS EARTHWORK FROM THE SITE. C. ALL CONSTRUCTION DEBRIS AND OTHER WASTE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN ACCORDANCE WITH APPLICABLE REGULATORY AGENCY REQUIREMENTS OR AS DIRECTED BY THE OWNER OR THE OWNER'S ENGINEER. II. EROSION/TURBIDITY CONTROL . THE INSTALLATION OF TEMPORARY EROSION CONTROL BARRIERS SHALL BE COORDINATED WITH THE CONSTRUCTION OF THE PERMANENT EROSION CONTROL FEATURES TO THE EXTENT NECESSARY TO ASSURE ECONOMICAL, EFFECTIVE AND CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOUT THE LIFE OF THE CONSTRUCTION PHASE. THE TYPE OF EROSION CONTROL BARRIERS USED SHALL BE GOVERNED BY THE NATURE OF THE CONSTRUCTION OPERATION AND SOIL TYPE THAT WILL BE EXPOSED. SILTY AND CLAYEY MATERIAL USUALLY REQUIRE SOLID SEDIMENT BARRIERS TO PREVENT TURBID WATER DISCHARGE, WHILE SANDY MATERIAL MAY NEED ONLY SILT SILT FENCE TO PREVENT EROSION. FLOATING TURBIDITY CURTAINS SHALL BE USED IN OPEN WATER SITUATIONS. DIVERSION DITCHES OR SWALES MAY BE REQUIRED TO PREVENT TURBID STORM WATER RUNOFF FROM BEING DISCHARGED TO WETLANDS OR OTHER WATER BODIES. IT MAY BE NECESSARY TO EMPLOY A COMBINATION OF BARRIERS, DITCHES AND OTHER EROSION/TURBIDITY CONTROL MEASURES IF CONDITIONS WARRANT. CONSTRUCTION OPERATIONS IN OR ADJACENT TO WETLANDS SHALL BE RESTRICTED TO THOSE AREAS IDENTIFIED IN THE PLANS AND IN THE SPECIFICATIONS. EXCEPT AS NECESSARY FOR CONSTRUCTION, EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN WETLANDS OR IN A POSITION CLOSE ENOUGH THERETO TO BE WASHED AWAY BY HIGH WATER OR RUNOFF. THE CONTRACTOR SHALL SCHEDULE HIS OPERATIONS SUCH THAT THE AREA OF UNPROTECTED ERODIBLE EARTH EXPOSED AT ANY ONE TIME IS NOT LARGER THAN THE MINIMUM AREA NECESSARY FOR EFFICIENT CONSTRUCTION OPERATIONS, AND THE DURATION OF EXPOSED, UNCOMPLETED CONSTRUCTION TO THE ELEMENTS SHALL BE AS SHORT AS PRACTICABLE. CLEARING AND GRUBBING SHALL BE SO SCHEDULED AND PERFORMED THAT GRADING OPERATIONS CAN FOLLOW IMMEDIATELY THEREAFTER, AND GRADING OPERATIONS SHALL BE SCHEDULED AND PERFORMED THAT PERMANENT EROSION CONTROL FEATURES CAN FOLLOW IMMEDIATELY THEREAFTER IF CONDITIONS ON THE PROJECT PERMIT. THE CONTRACTOR SHALL PROVIDE ROUTINE MAINTENANCE OF PERMANENT AND TEMPORARY EROSION CONTROL FEATURES UNTIL THE PROJECT IS COMPLETE AND ALL DISTURBED SOILS ARE STABILIZED. SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SEEDING DATES MOUNTAINS ABOVE 2500 FEET: FEB. 15 - MAY 15 BELOW 2500 FEET: FEB. 1- MAY 1 PIEDMONT JAN. 1 - MAY 1 COASTAL PLAIN DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.108 TEMPORARY SEEDING RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE SPECIES RATE (LB/ACRE) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS MAY 15 - AUG. 15 PIEDMONT MAY 1 - AUG. 15 COASTAL PLAIN APR. 15- AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. ABLE 6.10C EMPORARY SEEDING RECOMMENDATIONS FOR FALL EEDING MIXTURE 'YE (GRAIN) 120 EEDING DATES IOUNTAINS AUG. 15 - DEC. 15 :OASTAL PLAIN SND PIEDMONT AUG. 15 - DEC. 30 OIL AMENDMENTS OLLOW SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AN ,000 LB/ACRE 10-10-10 FERTILIZER. 1ULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, )R A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE ISED AS A MULCH ANCHORING TOOL. AINTENANCE EPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LB/ACRE F NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTENT TEMPORARY COVER BEYOND JNE 15, OVERSEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR OREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. PERMANENT SEEDING REQUIREMENTS PER NCDENR EROSION AND TABLE 6.11 K PERMANENT SEEDING FOR STEEP SLOPES OR POOR SOILS; LOW MAINTENANCE SEEDING MIXTURE SPECIES RATE (LB/ACRE) TALL FESCUE 100 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 SEEDING NOTES 1. IN EASTERN PIEDMONT ADD 25 LB/ACRE PENSACOLA BAHIAGRASS OR 10 LB/ACRE COMMON BERMUDAGRASS. USE COMMON BERMUDAGRASS ONLY WHERE IT IS UN- LIKELY TO BECOME A PEST 2. AFTER AUG. 15 USE UNSCARIFIED SERICEA SEED 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND SUBSTITUTE 40 LB/ACRE BAHIAGRASS OR 15 LB/ACRE BERMUDAGRASS. 4. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 LB/ACRE HULLED BER- MUDAGRASS. HOWEVER, IT IS PREFERABLE TO SEED TEMPORARY COVER AND SEEE FESCUE IN SEPT. NURSE PLANTS BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15 AND 40 LB/ACRE RYE (GRAIN) SEEDING DATES BEST POSSIBLE FALL: AUG. 25 - SEPT. 15 AUG. 20 - OCT. 25 LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15 FALL IS BEST FOR TALL FESCUE AND LATE WINTER LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. USE UNHULLED BERMUDAGRASS SEED IN FALL. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000-5000 LB/ACRE GRAIN STRAW, OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR MULCH BY TACKING WITH ASPHALT, ROVING, OR NETTING. NETTING IS THE PREFERRED ANCHORING METHOD ON STEEP SLOPES. MAINTENANCE REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. NOTES DE -WATERING: THE CONTRACTOR SHALL AT ALL TIMES PROVIDE AND MAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE AND PROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THE EXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALL EXCAVATIONS DRY UNTIL SUCH TIME AS PIPE LAYING AND GRADING IS COMPLETED AND STRUCTURES TO BE BUILT THEREIN ARE COMPLETED. NO WATER SHALL BE ALLOWED TO RISE AROUND THE PIPE IN UNBACKFILLED TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVER MASONRY UNTIL THE CONCRETE OR MORTAR HAS SET (MINIMUM 24 HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT SILTATION AND EROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION. VIII. PROTECTION OF EXISTING UTILITIES THE CONTRACTOR SHALL CONTACT THE APPROPRIATE AGENCY FOR THE EXACT FIELD LOCATIONS OF ALL WATER, SEWER, ELECTRIC, TELEPHONE, TELEVISION AND ANY OTHER UNDERGROUND AND OVERHEAD UTILITY BEFORE STARTING CONSTRUCTION. THE OMISSION FROM OR THE INCLUSION OF UTILITY LOCATION ON THE CONTRACT DRAWINGS IS NOT TO BE CONSIDERED AS THE NON-EXISTANCE OF OR A DEFINITE LOCATION OF EXISTING UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION AND DEPTH OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF WORK. THE FOLLOWING LISTING OF UTILITY COMPANIES (WHICH MAY OR MAY NOT BE COMPLETE) MAY HAVE EXISTING UNDERGROUND OR OVERHEAD UTILITIES IN THE CONTRACT VICINITY. INCH HICK LAYER OF LEAN CO114 E MAY BE PLACED IN SUCH AREAS. THE SITE . WATER & SEWER SHALL BE GRADED TO TRANSPORT SURFACE RUNOFF AWAY FROM THE STRUCTURES AND NECESSARY TO MAINTAIN A BARRIER. III. SITE PLAN AND COORDINATE GEOMETRY PAVED AREAS. WATER SHALL NOT BE ALLOWED TO ACCUMULATE (POND) AROUND UNION POWER COOPERATIVE A. PRELIMINARY ARCHITECTURAL BUILDING, AND PLUMBING PLANS HAVE NOT BEEN BUILDING PERIMETERS OR ON PAVED AREAS. PIEDMONT NATURAL GAS 5. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED RECEIVED BY EEI. N. GENERAL ROCK EXCAVATION: ROCK SHALL BE DEFINED AS ANY MATERIAL WHICH ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, B. SITE PLAN PREPARED BY EEI. CANNOT BE EXCAVATED WITH A SINGLE - TOOTH RIPPER DRAWN BY A CRAWLER DENSE VEGETATIVE COVER. C. STRUCTURAL PLANS HAVE NOT BEEN RECEIVED BY EEI. TRACTOR HAVING A MINIMUM DRAW BAR PULL RATED AT NOT LESS THAN 56,000 G.S. 113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO D. ELECTRICAL, MECHANICAL, AND FIRE SAFETY PLANS HAVE NOT BEEN RECEIVED BY POUNDS (CATERPILLAR D8K OR EQUIVALENT). THE VOLUME OF ROCK EXCAVATION SHALL GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR BE DETERMINED BY A LICENSED SURVEYOR BY THE AVERAGE END AREA METHOD. THE EEI. CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCALED PLAN WITH SUFFICIENT OTHER ADEQUATE EROSION -CONTROL DEVISES OR STRUCTURES. IN ANY EVENT, E. BOUNDARY SURVEY & TOPOGRAPHIC SURVEY PREPARED BY EAGLE ENGINEERING SLOPES LEFT EXPOSED SHALL WITHIN CALENDAR DAYS OF COMPLETION OF ANY ' ELEVATION POINTS TO ACCURATELY DEFINE THE VOLUME OF ROCK EXCAVATED. THE 14 INC. PHASE OF GRADING, BE PLANTED OR OTHERWISE BE PROVIDED WITH TEMPORARY OR DEPTH OF ROCK SHALL BE DEFINED AS FROM TOP OF ROCK TO THE CONTRACT F. ALL POINTS AND MONUMENTS SHALL BE SURVEYED UPON MOBILIZATION TO VERIFY SPECIFIED ELEVATION FOR EXCAVATION. CONTRACTOR SHALL BE COMPENSATED FOR ROCK PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN THEIR ACCURACY. ANY DISCREPANCIES DISCOVERED MUST BE BROUGHT TO THE EXCAVATION AS DEFINED HEREIN IN ACCORDANCE WITH CONTRACT UNIT PRICES. EROSION. ATTENTION OF THE ENGINEER IN WRITING. G. MONUMENTS AND OTHER SURVEY CONTROL POINTS SHALL BE PROTECTED FROM VI. DRAINAGE: G.S. 113A-57(3), PROVISIONS FOR A PERMANENT GROUND COVER SUFFICIENT TO DAMAGE AND DISTURBANCE. IF ANY CONTROL POINTS ARE DAMAGED OR A. ALL STORM SEWER PIPE SHALL BE REINFORCED CONCRETE PIPE UNLESS OTHERWISE RESTRAIN EROSION MUST BE ACCOMPLISHED WITHIN 15 WORKING DAYS OR 90 DISTURBED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE NOTED ON PLANS. ALL DRAINAGE STRUCTURES SHALL BE IN ACCORDANCE WITH NCDOT CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT, ENGINEER AND REPLACE THE CONTROL POINTS TO THEIR ORIGINAL CONDITION AT STANDARDS UNLESS OTHERWISE NOTED. WHICHEVER PERIOD IS SHORTER. HIS OWN EXPENSE. B. PIPE LENGTHS SHOWN ARE APPROXIMATE AND TO CENTER OF DRAINAGE STRUCTURE OR H. ALL ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM. TO THE END OF THE PIPE. CONTRACTOR SHALL VERIFY ALL QUANTITIES PRIOR TO TEMPORARY SEEDING REQUIREMENTS PER NCDENR EROSION AND I. LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND SUBMITTAL OF BID. OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY C. ALL DRAINAGE STRUCTURE GRATES AND COVERS SHALL BE AS PER NCDOT STANDARDS THE LOCATIONS, ELEVATIONS AND DIMENSIONS OF ALL EXISTING UTILITIES, UNLESS OTHERWISE NOTED. STRUCTURES AND OTHER FEATURES AFFECTING THIS WORK PRIOR TO CONSTRUCTION. D. ALL STORM DRAINAGE PIPING SHALL BE SUBJECT TO A VISUAL INSPECTION BY THE J. UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL FURNISH OWNER'S OWNER'S ENGINEER PRIOR TO THE PLACEMENT OF BACKFILL. CONTRACTOR TO NOTIFY THE ENGINEER WITH COMPLETE "AS -BUILT" INFORMATION CERTIFIED BY A REGISTERED ENGINEER 48 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. LAND SURVEYOR. THIS "AS -BUILT INFORMATION SHALL BE PRODUCED ON AUTOCAD E. THE CONTRACTOR SHALL MAINTAIN AND PROTECT FROM MUD, DIRT, DEBRIS, ETC. THE VERSION 12, OR LATER, AND UPON COMPLETION, THE CONTRACTOR SHALL STORM DRAINAGE SYSTEM UNTIL FINAL ACCEPTANCE OF THE PROJECT. THE CONTRACTOR FURNISH EAGLE ENGINEERING WITH DISKS OF ALL DRAWINGS, ONE SET OF MAY BE REQUIRED TO RECLEAN PIPES AND INLETS FOR THESE PURPOSES. REPRODUCIBLE MYLARS, AND FIVE SETS OF BLUEPRINTS. THE "AS -BUILT" INFORMATION SHALL CLEARLY AND ACCURATELY REPRESENT ALL CONSTRUCTED ITEMS INCLUDING, BUT NOT LIMITED TO: V 1. ELEVATIONS OF ALL STORM SEWER AND SANITARY SEWER STRUCTURE BOTTOMS, A TOPS AND INVERTS. 2. FIELD MEASURED LENGTHS OF PIPES FOR ALL INSTALLED UTILITIES, CONDUITS, SLEEVES, ETC. 3. LOCATIONS OF ALL STRUCTURES PIPES CONDUITS SLEEVES ETC. B 4. CALCULATED SLOPE OF ALL SANITARY SEWER AND STORM SEWER LINES. 5. HORIZONTAL AND VERTICAL CONTROL OF ALL WATER MAIN FITTINGS AND APPURTENANCES, AND HORIZONTAL AND VERTICAL CONTROL ON THE TOP OF WATER MAINS AT ALL CROSSINGS, AND A MINIMUM OF EVERY 200 LINEAR FEET OF PIPE. 6. HORIZONTAL AND VERTICAL CONTROL OF ALL TOP OF BANKS, TOE OF SLOPES, ALL GRADE BREAKS, BUILDINGS, PONDS, ETC. K. ALL DIMENSIONS SHOWN ON PLAN ARE TO FACE OF BUILDING, EDGE OF PAVEMENT, CENTERLINE OF STRUCTURE, OR END OF PIPE UNLESS NOTED OTHERWISE. C IV. CLEARING/DEMOLITION A. THE CONTRACTOR SHALL CLEAR AND GRUB ONLY THOSE PORTIONS OF THE SITE E NECESSARY FOR CONSTRUCTION. DISTURBED AREAS WILL BE SEEDED, MULCHED, SODDED OR PLANTED WITH OTHER APPROVED LANDSCAPE MATERIAL IMMEDIATELY FOLLOWING CONSTRUCTION. B. THE TOP 6" OF GROUND REMOVED DURING CLEARING AND GRUBBING SHALL BE STOCKPILED AT A SITE DESIGNATED BY THE OWNER OR THE OWNER'S ENGINEER TO BE USED FOR LANDSCAPING PURPOSES, UNLESS OTHERWISE DIRECTED BY THE OWNER OR THE OWNER'S ENGINEER. REMAINING EARTHWORK THAT RESULTS FROM CLEARING AND GRUBBING OR SITE EXCAVATION IS TO BE UTILIZED ON-SITE IF REQUIRED, PROVIDED THAT THE MATERIAL IS DEEMED SUITABLE FOR CONSTRUCTION F BY THE OWNER'S SOILS TESTING COMPANY. EXCESS MATERIAL IS TO BE EITHER STOCKPILED ON THE SITE AS DIRECTED BY THE OWNER OR OWNER'S ENGINEER, OR REMOVED FROM THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ANY PERMITS THAT ARE NECESSARY FOR REMOVING EXCESS EARTHWORK FROM THE SITE. C. ALL CONSTRUCTION DEBRIS AND OTHER WASTE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN ACCORDANCE WITH APPLICABLE REGULATORY AGENCY REQUIREMENTS OR AS DIRECTED BY THE OWNER OR THE OWNER'S ENGINEER. II. EROSION/TURBIDITY CONTROL . THE INSTALLATION OF TEMPORARY EROSION CONTROL BARRIERS SHALL BE COORDINATED WITH THE CONSTRUCTION OF THE PERMANENT EROSION CONTROL FEATURES TO THE EXTENT NECESSARY TO ASSURE ECONOMICAL, EFFECTIVE AND CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOUT THE LIFE OF THE CONSTRUCTION PHASE. THE TYPE OF EROSION CONTROL BARRIERS USED SHALL BE GOVERNED BY THE NATURE OF THE CONSTRUCTION OPERATION AND SOIL TYPE THAT WILL BE EXPOSED. SILTY AND CLAYEY MATERIAL USUALLY REQUIRE SOLID SEDIMENT BARRIERS TO PREVENT TURBID WATER DISCHARGE, WHILE SANDY MATERIAL MAY NEED ONLY SILT SILT FENCE TO PREVENT EROSION. FLOATING TURBIDITY CURTAINS SHALL BE USED IN OPEN WATER SITUATIONS. DIVERSION DITCHES OR SWALES MAY BE REQUIRED TO PREVENT TURBID STORM WATER RUNOFF FROM BEING DISCHARGED TO WETLANDS OR OTHER WATER BODIES. IT MAY BE NECESSARY TO EMPLOY A COMBINATION OF BARRIERS, DITCHES AND OTHER EROSION/TURBIDITY CONTROL MEASURES IF CONDITIONS WARRANT. CONSTRUCTION OPERATIONS IN OR ADJACENT TO WETLANDS SHALL BE RESTRICTED TO THOSE AREAS IDENTIFIED IN THE PLANS AND IN THE SPECIFICATIONS. EXCEPT AS NECESSARY FOR CONSTRUCTION, EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN WETLANDS OR IN A POSITION CLOSE ENOUGH THERETO TO BE WASHED AWAY BY HIGH WATER OR RUNOFF. THE CONTRACTOR SHALL SCHEDULE HIS OPERATIONS SUCH THAT THE AREA OF UNPROTECTED ERODIBLE EARTH EXPOSED AT ANY ONE TIME IS NOT LARGER THAN THE MINIMUM AREA NECESSARY FOR EFFICIENT CONSTRUCTION OPERATIONS, AND THE DURATION OF EXPOSED, UNCOMPLETED CONSTRUCTION TO THE ELEMENTS SHALL BE AS SHORT AS PRACTICABLE. CLEARING AND GRUBBING SHALL BE SO SCHEDULED AND PERFORMED THAT GRADING OPERATIONS CAN FOLLOW IMMEDIATELY THEREAFTER, AND GRADING OPERATIONS SHALL BE SCHEDULED AND PERFORMED THAT PERMANENT EROSION CONTROL FEATURES CAN FOLLOW IMMEDIATELY THEREAFTER IF CONDITIONS ON THE PROJECT PERMIT. THE CONTRACTOR SHALL PROVIDE ROUTINE MAINTENANCE OF PERMANENT AND TEMPORARY EROSION CONTROL FEATURES UNTIL THE PROJECT IS COMPLETE AND ALL DISTURBED SOILS ARE STABILIZED. SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SEEDING DATES MOUNTAINS ABOVE 2500 FEET: FEB. 15 - MAY 15 BELOW 2500 FEET: FEB. 1- MAY 1 PIEDMONT JAN. 1 - MAY 1 COASTAL PLAIN DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.108 TEMPORARY SEEDING RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE SPECIES RATE (LB/ACRE) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS MAY 15 - AUG. 15 PIEDMONT MAY 1 - AUG. 15 COASTAL PLAIN APR. 15- AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. ABLE 6.10C EMPORARY SEEDING RECOMMENDATIONS FOR FALL EEDING MIXTURE 'YE (GRAIN) 120 EEDING DATES IOUNTAINS AUG. 15 - DEC. 15 :OASTAL PLAIN SND PIEDMONT AUG. 15 - DEC. 30 OIL AMENDMENTS OLLOW SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AN ,000 LB/ACRE 10-10-10 FERTILIZER. 1ULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, )R A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE ISED AS A MULCH ANCHORING TOOL. AINTENANCE EPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LB/ACRE F NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTENT TEMPORARY COVER BEYOND JNE 15, OVERSEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR OREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. PERMANENT SEEDING REQUIREMENTS PER NCDENR EROSION AND TABLE 6.11 K PERMANENT SEEDING FOR STEEP SLOPES OR POOR SOILS; LOW MAINTENANCE SEEDING MIXTURE SPECIES RATE (LB/ACRE) TALL FESCUE 100 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 SEEDING NOTES 1. IN EASTERN PIEDMONT ADD 25 LB/ACRE PENSACOLA BAHIAGRASS OR 10 LB/ACRE COMMON BERMUDAGRASS. USE COMMON BERMUDAGRASS ONLY WHERE IT IS UN- LIKELY TO BECOME A PEST 2. AFTER AUG. 15 USE UNSCARIFIED SERICEA SEED 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND SUBSTITUTE 40 LB/ACRE BAHIAGRASS OR 15 LB/ACRE BERMUDAGRASS. 4. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 LB/ACRE HULLED BER- MUDAGRASS. HOWEVER, IT IS PREFERABLE TO SEED TEMPORARY COVER AND SEEE FESCUE IN SEPT. NURSE PLANTS BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15 AND 40 LB/ACRE RYE (GRAIN) SEEDING DATES BEST POSSIBLE FALL: AUG. 25 - SEPT. 15 AUG. 20 - OCT. 25 LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15 FALL IS BEST FOR TALL FESCUE AND LATE WINTER LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. USE UNHULLED BERMUDAGRASS SEED IN FALL. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000-5000 LB/ACRE GRAIN STRAW, OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR MULCH BY TACKING WITH ASPHALT, ROVING, OR NETTING. NETTING IS THE PREFERRED ANCHORING METHOD ON STEEP SLOPES. MAINTENANCE REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. NOTES DE -WATERING: THE CONTRACTOR SHALL AT ALL TIMES PROVIDE AND MAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE AND PROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THE EXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALL EXCAVATIONS DRY UNTIL SUCH TIME AS PIPE LAYING AND GRADING IS COMPLETED AND STRUCTURES TO BE BUILT THEREIN ARE COMPLETED. NO WATER SHALL BE ALLOWED TO RISE AROUND THE PIPE IN UNBACKFILLED TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVER MASONRY UNTIL THE CONCRETE OR MORTAR HAS SET (MINIMUM 24 HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT SILTATION AND EROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION. VIII. PROTECTION OF EXISTING UTILITIES THE CONTRACTOR SHALL CONTACT THE APPROPRIATE AGENCY FOR THE EXACT FIELD LOCATIONS OF ALL WATER, SEWER, ELECTRIC, TELEPHONE, TELEVISION AND ANY OTHER UNDERGROUND AND OVERHEAD UTILITY BEFORE STARTING CONSTRUCTION. THE OMISSION FROM OR THE INCLUSION OF UTILITY LOCATION ON THE CONTRACT DRAWINGS IS NOT TO BE CONSIDERED AS THE NON-EXISTANCE OF OR A DEFINITE LOCATION OF EXISTING UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION AND DEPTH OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF WORK. THE FOLLOWING LISTING OF UTILITY COMPANIES (WHICH MAY OR MAY NOT BE COMPLETE) MAY HAVE EXISTING UNDERGROUND OR OVERHEAD UTILITIES IN THE CONTRACT VICINITY. IX. SANITARY SEWER AND WATER DISTRIBUTION A. SANITARY SEWERS AND STORM SEWERS SHOULD ALWAYS CROSS UNDER WATER MAINS. SANITARY SEWERS AND STORM SEWERS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. B. WHERE SANITARY SEWERS AND STORM SEWERS MUST CROSS A WATER MAIN WITH LESS THAN 18 INCHES VERTICAL DISTANCE, BOTH THE SEWER AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS IF IT IS NOT AVAILABLE IN THE SIZE PROPOSED). SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE LEAK FREE AND MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT THE CROSSING. C. ALL CROSSINGS SHALL BE ARRANGED SO THAT THE SEWER PIPE JOINTS AND THE WATER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING PIPES CENTERED ON THE CROSSING). Q ( ) D. WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE, THE NEW PIPE SHALL BE CONSTRUCTED OF DIP AND THE CROSSING SHALL BE ARRANGED TO MEET THE REQUIREMENTS ABOVE. E. A MINIMUM 10 -FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN ANY TYPE OF SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS. F. IN CASES WHERE IT IS NOT POSSIBLE TO MAINTAIN A 10 -FOOT HORIZONTAL SEPARATION, THE WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER OR FORCE MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. G. WHERE IT IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 18 INCHES IN PARALLEL INSTALLATIONS, THE WATER MAIN SHALL BE CONSTRUCTED OF DIP AND THE SEWER OR THE FORCE MAIN SHALL BE CONSTRUCTED OF DIP (IF AVAILABLE IN THE SIZE PROPOSED) WITH A MINIMUM VERTICAL SEPARATION OF 6 INCHES. THE WATER MAIN SHOULD ALWAYS BE ABOVE THE SEWER. JOINTS ON THE WATER MAIN SHALL BE LOCATED AS FAR APART AS POSSIBLE FROM THE JOINTS ON THE SEWER OR FORCE MAIN(STAGGERED JOINTS). H. ALL SANITARY SEWER MAINS, LATERALS AND FORCE MAINS SHALL HAVE A MINIMUM OF 36 INCHES OF COVER. I. ALL ON SITE P.V.C. GRAVITY SANITARY SEWER PIPE SHALL BE MADE OF MATERIAL HAVING A CELL CLASSIFICATION OF 12454 B, 12454 C OR 13354 B AS DEFINED IN ASTM D-1784 AND CONFORM TO THE REQUIREMENTS OF SDR 26. ELASTOMERIC GASKET JOINTS SHALL BE UTILIZED. J. ALL ON SITE DUCTILE IRON PIPE SHALL BE CLASS 52 AND SHALL RECEIVE INTERIOR AND EXTERIOR BITUMINOUS COATING IN ACCORDANCE WITH ANSI A 21.6, A 21.8, OR A 21.51. K. SANITARY SERVICE CONNECTION LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE. L. ALL SANITARY SEWER WORK SHALL CONFORM TO UNION COUNTY STANDARDS AND SPECIFICATIONS, UNION COUNTY WATER & SEWER EXTENSION POLICY & TO UNION COUNTY WATER & SEWER EXTENSION ORDINANCE. M. PRIOR TO COMMENCING WORK WHICH REQUIRES CONNECTING NEW SANITARY SEWER LINES TO EXISTING LINES OR APPURTENANCES, THE CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL EXISTING UTILITIES NEAR THE POINT OF CONNECTION AND NOTIFY OWNER'S ENGINEER OF ANY CONFLICTS OR DISCREPANCIES WITH DESIGN INFORMATION SHOWN IN THESE PLANS. CONTRACTOR SHALL NOTIFY ENGINEER AND UNION COUNTY PUBLIC WORKS INSPECTOR AT LEAST 48 HOURS IN ADVANCE OF SCHEDULED WORK. N. ALL GRAVITY SEWER PIPING SHALL BE SUBJECT TO A VISUAL INSPECTION BY THE OWNER'S ENGINEER AND UNION COUNTY PUBLIC WORKS PRIOR TO PLACEMENT OF AND PAVING AND AGAIN PRIOR TO OBTAINING CERTIFICATE OF OCCUPANCY. CONTRACTOR TO NOTIFY THE ENGINEER AND UNION COUNTY PUBLIC WORKS 48 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. 0. THE CONTRACTOR SHALL PERFORM ALL NECESSARY TESTING IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS STANDARDS. SAID TESTS ARE TO BE CERTIFIED BY THE ENGINEER OF RECORD AND SUBMITTED TO THE REGULATORY AGENCY FOR APPROVAL. COORDINATION OF TESTING AND NOTIFICATION OF ALL PARTIES IS THE CONTRACTOR'S RESPONSIBILITY. P. ALL WATER MAINS SHALL HAVE A MINIMUM OF 36 INCHES OF COVER. Q. ALL WATER SYSTEM WORK SHALL CONFORM TO UNION COUNTY STANDARDS AND SPECIFICATIONS, UNION COUNTY WATER AND SEWER EXTENSION POLICY & TO UNION COUNTY WATER & SEWER EXTENSION ORDINANCE. R. ALL ON SITE PVC WATER MAINS 4 INCHES THROUGH 12 INCHES SHALL BE IN ACCORDANCE WITH AWWA C-900 AND SHALL BE CLASS 150 DR 18. ALL ON-SITE PVC WATER MAINS 2" TO 3" SHALL BE CLASS 1120 AND MEET REQUIREMENTS OF SDR 21 IN ACCORDANCE WITH ASTM D-2241. WATER MAINS SMALLER THAN 1 1/2" SHALL BE CLASS 1120 OR 1220 SCHEDULE 80 AND MEET REQUIREMENTS OF ASTM D-1785. S. PVC PIPE FOR FIRE PROTECTION AWWA C900 CLASS 200 WITH AN SDR OF 14 OR LESS T. ALL DUCTILE IRON PIPE SHALL CONFORM TO THE REQUIREMENTS OF ANSI STANDARD A21.51, MINIMUM CLASS 50. JOINTS FOR DUCTILE IRON PIPE SHALL BE MECHANICAL OR PUSH -ON JOINTS. PIPE SHALL HAVE AN EXTERIOR BITUMINOUS COATING IN ACCORDANCE WITH ANSI A21.51. PIPE INTERIOR SHALL HAVE A CEMENT MORTAR LINING WITH AN ASPHALTIC SEAL COAT CONFORMING TO AWWA/ANSI C104/A21.4. THE WEIGHT AND CLASS DESIGNATION SHALL BE PAINTED IN WHITE ON THE EXTERIOR SURFACE OF ALL PIPES AND FITTINGS. MANUFACTURER'S CODE OR SERIAL NUMBER SHALL BE PROVIDED ON THE BELL OF EACH PIPE JOINT. U. ALL DUCTILE FITTINGS SHALL BE MECHANICAL JOINT WITH A MINIMUM PRESSURE RATING OF 250 PSI AND SHALL CONFORM TO THE REQUIREMENTS OF ANSI/AWWA STANDARD A21.10/C110. ALL FITTINGS SHALL BE COATED AND LINED AS SPECIFIED ABOVE FOR DUCTILE IRON PIPE. V. CONTRACTOR SHALL INSTALL TEMPORARY BLOWOFFS AT THE END OF WATER SERVICE LATERALS TO BUILDINGS TO ASSURE ADEQUATE FLUSHING AND DISINFECTION. W. THRUST BLOCKING SHALL BE PROVIDED AT ALL FITTINGS AND HYDRANTS IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS. X. POINTS OF CONNECTION OF THE EXTERNAL WATER LINES ARE TO COINCIDE WITH THE BUILDING PLUMBING AS SHOWN ON THE BUILDING PLUMBING PLANS. CONNECTION LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE. Y. FIRE LINES TO BUILDINGS SHALL BE INSTALLED BY A CONTRACTOR DULY LICENSED BY THE STATE FIRE MARSHALL'S OFFICE. CONTRACTOR TO VERIFY REQUIREMENTS PRIOR TO CONSTRUCTION. Z. ALL COMPONENTS OF THE WATER SYSTEM, INCLUDING FITTINGS, HYDRANTS, CONNECTIONS, AND VALVES SHALL REMAIN UNCOVERED UNTIL PROPERLY INSPECTED AND ACCEPTED BY THE OWNER'S ENGINEER AND THE UNION COUNTY PUBLIC WORKS. PRESSURE TESTS SHALL BE IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS SPECIFICATIONS. CONTRACTOR TO NOTIFY OWNER'S ENGINEER AND UNION COUNTY PUBLIC WORKS INSPECTORS 48 HOURS IN ADVANCE OF PERFORMING TESTS. AA. DISINFECTION: SHALL CONFORM TO AWWA C651. ALL NEW WATER MAINS SHALL BE DISINFECTED AFTER THEY HAVE BEEN PRESSURE TESTED. THE MAIN SHALL BE THOROUGHLY FLUSHED AT A RATE OF 2 FEET PER SECOND WITH CLEAN WATER AFTER WHICH A CHLORINE SOLUTION OF 50 PARTS PER MILLION SHALL BE INDUCED. THE CHLORINE SOLUTION SHALL REMAIN IN THE LINES FOR A MINIMUM OF 24 HOURS. THE LINES SHALL AGAIN BE FLUSHED AT A RATE OF 2 FEET PER SECOND WITH CLEAN WATER UNTIL THE CHLORINE RESIDUAL IS REDUCED TO THAT OF THE SUPPORTING SYSTEM. SAMPLES SHALL BE THEN COLLECTED AND TESTED FOR COLIFORM BACTERIA. ANALYSIS SHALL BE BY A STATE CERTIFIED LABORATORY USING THE MULTIPLE TUBE FEREMENTATION METHOD. ONE SAMPLE SHALL BE COLLECTED FROM EACH DEAD END SEGMENT OF THE PIPELINES INSTALLED. IF BACTERIA OF ANY TIME IS FOUND, THE TEST SHALL BE REPEATED UNTIL THE LINES ARE CLEAN. BB. WATER MAIN SHALL HAVE 14 GA. BLUE COATED TRACER WIRE ON ALL SERVICES AND MAINS BURIED OVER THE WATER MAIN. CC. FIRE HYDRANTS SHALL BE PLACED A MINIMUM DISTANCE OF 6' BOC AND HAVE A CLEAR SPACE OF 3' FROM ANY PERMANENT STRUCTURES. DD. WATER VALVES SHALL COMPLY WITH APPROPRIATE AWWA STANDARDS. 1. GATE VALVES 2 -INCHES: SHALL CONFORM TO ANSI AWWA A21.11/C111 FOR CAST IRON BODIED BRONZE MOUNTED PARALLEL DOUBLE DISC, NON RISING STEM VALVES. VALVES SHALL BE RATED AT 200 PSIG WORKING PRESSURE AND 400 PSIG TEST PRESSURE. END CONNECTIONS SHALL BE STANDARD FEMALE IRON PIPE THREADS OR ANSI/AWWA A21.11 /C111 MECHANICAL JOINTS FOR BURIED LOCATIONS ADN ANSI 816.1 FLANGES FOR EXPOSED LOCATIONS. VALVE OPERATOR SHALL BE A 2 INCH SQUARE NUT FOR BURIED LOCATIONS AND STANDARD HANDWHEEL FOR EXPOSED LOCATIONS. ALL VALVES SHALL BE OPEN LEFT. 2. GATE VALVES 6 -INCHES THROUGH 16 -INCHES: SHALL CONFORM TO AWWA C509 FOR BRONZE MOUNTED, RESILIENT SEATED, CAST IRON BODIED GATE VALVES. VALVE BODY SHALL BE RATED FOR 200 PSIG WORKING PRESSURE AND 400 PSIG TEST PRESSURE. PROVIDE VALVE WITH SOLID WEDGE, NON RISING STEM CONSTRUCTION. VALVES SHALL EBE SEALED RUBBER "0" RING SEALS BOTH ABOVE AND BELOW THE THRUST RING. VALVES STEMS SHALL BE OF BRONZE. INTERIOR OF THE VALVES SHALL BE COATED IN ACCORDANCE WITH AWWA C550. END CONNECTIONS SHALL CONFORM TO ANSI/AWWA AS2.22/C111 MECHANICAL JOINTS FOR BURIED LOCATIONS AND ANSI B16.1 FLANGES FOR EXPOSED LOCATIONS. VALVE OPERATORS SHALL BE 2 INCH SQUARE NUTS FOR BURIED LOCATIONS OR STANDARD HANDWHEEL FOR EXPOSED LOCATIONS. ALL VALVES SHALL BE OPEN LEFT. IN LINE VALVES TO BE INSTALLED EVERY 2000 FEET OR EVERY OTHER HYDRANT. EE. WATER MAINS SHALL BE SUBJECT TO BOTH A PRESSURE TEST AND A LEAKAGE TEST. THE CONTRACTOR MAY BE BILLED FOR THE AMOUNT OF WATER USED. 1. PRESSURE TEST: SHALL CONFORM TO AWWA STANDARD C605 FOR PVC PIPE AND AWWA C600 FOR DUCTILE IRON. THE TEST PRESSURE SHALL BE 200 PSIG AND THE DURATION OF THE TEST SHALL BE NOT LESS THAN 2 HOURS OR MORE THAN 24 HOURS. THE DURATION OF THE TEST WILL BE DETERMINED BY THE COUNTY ENGINEER AS THE TEST PROGRESSES. PRESSURE SHALL NOT BE ALLOWED TO VARY MORE THAN 5 PSIG DURING THE TEST. 2. LEAKAGE TEST: SHALL BE CONDUCTED ALONG WITH THE PRESSURE TEST. LEAKAGE WILL BE DEFINED AS THE AMOUNT OF WATER THAT MUST BE SUPPLIED TO THE NEWLY LAID LINES TO MAINTAIN THE TEST PRESSURE WITHIN A 5 PSIG RANGE OVER A SPECIFIED PERIOD OF TIME. ALLOWABLE LEAKAGE WILL BE COMPUTED BY THE FOLLOWING FORMULA: L = (S) (D) (SQRT P) / 148,000 WHERE: L = ALLOWABLE LEAKAGE IN GALLONS PER HOUR S = LENGTH OF PIPE TESTED, IN FEET D = NOMINAL DIAMETER OF PIPE IN INCHES P = TEST PRESSURE IN PSIG BUT NOT MORE THAN: 12.1 GALLONS PER INCH OF DIAMETER PER MILE OF PIPE PER 24 HOURS BASED ON 200 PSI TEST PRESSURE. UTILITY PROVIDERS 00 V_ WATER & SEWER UNION COUNTY PUBLIC WORKS 704-296-4210 TELEPHONE FRONTEIR COMMUNICATIONS 704-291-3145 ELECTRIC UNION POWER COOPERATIVE 704-289-3145 NATURAL GAS PIEDMONT NATURAL GAS 704-507-1912 IX. SANITARY SEWER AND WATER DISTRIBUTION A. SANITARY SEWERS AND STORM SEWERS SHOULD ALWAYS CROSS UNDER WATER MAINS. SANITARY SEWERS AND STORM SEWERS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. B. WHERE SANITARY SEWERS AND STORM SEWERS MUST CROSS A WATER MAIN WITH LESS THAN 18 INCHES VERTICAL DISTANCE, BOTH THE SEWER AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS IF IT IS NOT AVAILABLE IN THE SIZE PROPOSED). SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE LEAK FREE AND MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6 INCHES MUST BE MAINTAINED AT THE CROSSING. C. ALL CROSSINGS SHALL BE ARRANGED SO THAT THE SEWER PIPE JOINTS AND THE WATER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING PIPES CENTERED ON THE CROSSING). Q ( ) D. WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE, THE NEW PIPE SHALL BE CONSTRUCTED OF DIP AND THE CROSSING SHALL BE ARRANGED TO MEET THE REQUIREMENTS ABOVE. E. A MINIMUM 10 -FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN ANY TYPE OF SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS. F. IN CASES WHERE IT IS NOT POSSIBLE TO MAINTAIN A 10 -FOOT HORIZONTAL SEPARATION, THE WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER OR FORCE MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. G. WHERE IT IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 18 INCHES IN PARALLEL INSTALLATIONS, THE WATER MAIN SHALL BE CONSTRUCTED OF DIP AND THE SEWER OR THE FORCE MAIN SHALL BE CONSTRUCTED OF DIP (IF AVAILABLE IN THE SIZE PROPOSED) WITH A MINIMUM VERTICAL SEPARATION OF 6 INCHES. THE WATER MAIN SHOULD ALWAYS BE ABOVE THE SEWER. JOINTS ON THE WATER MAIN SHALL BE LOCATED AS FAR APART AS POSSIBLE FROM THE JOINTS ON THE SEWER OR FORCE MAIN(STAGGERED JOINTS). H. ALL SANITARY SEWER MAINS, LATERALS AND FORCE MAINS SHALL HAVE A MINIMUM OF 36 INCHES OF COVER. I. ALL ON SITE P.V.C. GRAVITY SANITARY SEWER PIPE SHALL BE MADE OF MATERIAL HAVING A CELL CLASSIFICATION OF 12454 B, 12454 C OR 13354 B AS DEFINED IN ASTM D-1784 AND CONFORM TO THE REQUIREMENTS OF SDR 26. ELASTOMERIC GASKET JOINTS SHALL BE UTILIZED. J. ALL ON SITE DUCTILE IRON PIPE SHALL BE CLASS 52 AND SHALL RECEIVE INTERIOR AND EXTERIOR BITUMINOUS COATING IN ACCORDANCE WITH ANSI A 21.6, A 21.8, OR A 21.51. K. SANITARY SERVICE CONNECTION LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE. L. ALL SANITARY SEWER WORK SHALL CONFORM TO UNION COUNTY STANDARDS AND SPECIFICATIONS, UNION COUNTY WATER & SEWER EXTENSION POLICY & TO UNION COUNTY WATER & SEWER EXTENSION ORDINANCE. M. PRIOR TO COMMENCING WORK WHICH REQUIRES CONNECTING NEW SANITARY SEWER LINES TO EXISTING LINES OR APPURTENANCES, THE CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL EXISTING UTILITIES NEAR THE POINT OF CONNECTION AND NOTIFY OWNER'S ENGINEER OF ANY CONFLICTS OR DISCREPANCIES WITH DESIGN INFORMATION SHOWN IN THESE PLANS. CONTRACTOR SHALL NOTIFY ENGINEER AND UNION COUNTY PUBLIC WORKS INSPECTOR AT LEAST 48 HOURS IN ADVANCE OF SCHEDULED WORK. N. ALL GRAVITY SEWER PIPING SHALL BE SUBJECT TO A VISUAL INSPECTION BY THE OWNER'S ENGINEER AND UNION COUNTY PUBLIC WORKS PRIOR TO PLACEMENT OF AND PAVING AND AGAIN PRIOR TO OBTAINING CERTIFICATE OF OCCUPANCY. CONTRACTOR TO NOTIFY THE ENGINEER AND UNION COUNTY PUBLIC WORKS 48 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. 0. THE CONTRACTOR SHALL PERFORM ALL NECESSARY TESTING IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS STANDARDS. SAID TESTS ARE TO BE CERTIFIED BY THE ENGINEER OF RECORD AND SUBMITTED TO THE REGULATORY AGENCY FOR APPROVAL. COORDINATION OF TESTING AND NOTIFICATION OF ALL PARTIES IS THE CONTRACTOR'S RESPONSIBILITY. P. ALL WATER MAINS SHALL HAVE A MINIMUM OF 36 INCHES OF COVER. Q. ALL WATER SYSTEM WORK SHALL CONFORM TO UNION COUNTY STANDARDS AND SPECIFICATIONS, UNION COUNTY WATER AND SEWER EXTENSION POLICY & TO UNION COUNTY WATER & SEWER EXTENSION ORDINANCE. R. ALL ON SITE PVC WATER MAINS 4 INCHES THROUGH 12 INCHES SHALL BE IN ACCORDANCE WITH AWWA C-900 AND SHALL BE CLASS 150 DR 18. ALL ON-SITE PVC WATER MAINS 2" TO 3" SHALL BE CLASS 1120 AND MEET REQUIREMENTS OF SDR 21 IN ACCORDANCE WITH ASTM D-2241. WATER MAINS SMALLER THAN 1 1/2" SHALL BE CLASS 1120 OR 1220 SCHEDULE 80 AND MEET REQUIREMENTS OF ASTM D-1785. S. PVC PIPE FOR FIRE PROTECTION AWWA C900 CLASS 200 WITH AN SDR OF 14 OR LESS T. ALL DUCTILE IRON PIPE SHALL CONFORM TO THE REQUIREMENTS OF ANSI STANDARD A21.51, MINIMUM CLASS 50. JOINTS FOR DUCTILE IRON PIPE SHALL BE MECHANICAL OR PUSH -ON JOINTS. PIPE SHALL HAVE AN EXTERIOR BITUMINOUS COATING IN ACCORDANCE WITH ANSI A21.51. PIPE INTERIOR SHALL HAVE A CEMENT MORTAR LINING WITH AN ASPHALTIC SEAL COAT CONFORMING TO AWWA/ANSI C104/A21.4. THE WEIGHT AND CLASS DESIGNATION SHALL BE PAINTED IN WHITE ON THE EXTERIOR SURFACE OF ALL PIPES AND FITTINGS. MANUFACTURER'S CODE OR SERIAL NUMBER SHALL BE PROVIDED ON THE BELL OF EACH PIPE JOINT. U. ALL DUCTILE FITTINGS SHALL BE MECHANICAL JOINT WITH A MINIMUM PRESSURE RATING OF 250 PSI AND SHALL CONFORM TO THE REQUIREMENTS OF ANSI/AWWA STANDARD A21.10/C110. ALL FITTINGS SHALL BE COATED AND LINED AS SPECIFIED ABOVE FOR DUCTILE IRON PIPE. V. CONTRACTOR SHALL INSTALL TEMPORARY BLOWOFFS AT THE END OF WATER SERVICE LATERALS TO BUILDINGS TO ASSURE ADEQUATE FLUSHING AND DISINFECTION. W. THRUST BLOCKING SHALL BE PROVIDED AT ALL FITTINGS AND HYDRANTS IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS. X. POINTS OF CONNECTION OF THE EXTERNAL WATER LINES ARE TO COINCIDE WITH THE BUILDING PLUMBING AS SHOWN ON THE BUILDING PLUMBING PLANS. CONNECTION LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE. Y. FIRE LINES TO BUILDINGS SHALL BE INSTALLED BY A CONTRACTOR DULY LICENSED BY THE STATE FIRE MARSHALL'S OFFICE. CONTRACTOR TO VERIFY REQUIREMENTS PRIOR TO CONSTRUCTION. Z. ALL COMPONENTS OF THE WATER SYSTEM, INCLUDING FITTINGS, HYDRANTS, CONNECTIONS, AND VALVES SHALL REMAIN UNCOVERED UNTIL PROPERLY INSPECTED AND ACCEPTED BY THE OWNER'S ENGINEER AND THE UNION COUNTY PUBLIC WORKS. PRESSURE TESTS SHALL BE IN ACCORDANCE WITH UNION COUNTY PUBLIC WORKS SPECIFICATIONS. CONTRACTOR TO NOTIFY OWNER'S ENGINEER AND UNION COUNTY PUBLIC WORKS INSPECTORS 48 HOURS IN ADVANCE OF PERFORMING TESTS. AA. DISINFECTION: SHALL CONFORM TO AWWA C651. ALL NEW WATER MAINS SHALL BE DISINFECTED AFTER THEY HAVE BEEN PRESSURE TESTED. THE MAIN SHALL BE THOROUGHLY FLUSHED AT A RATE OF 2 FEET PER SECOND WITH CLEAN WATER AFTER WHICH A CHLORINE SOLUTION OF 50 PARTS PER MILLION SHALL BE INDUCED. THE CHLORINE SOLUTION SHALL REMAIN IN THE LINES FOR A MINIMUM OF 24 HOURS. THE LINES SHALL AGAIN BE FLUSHED AT A RATE OF 2 FEET PER SECOND WITH CLEAN WATER UNTIL THE CHLORINE RESIDUAL IS REDUCED TO THAT OF THE SUPPORTING SYSTEM. SAMPLES SHALL BE THEN COLLECTED AND TESTED FOR COLIFORM BACTERIA. ANALYSIS SHALL BE BY A STATE CERTIFIED LABORATORY USING THE MULTIPLE TUBE FEREMENTATION METHOD. ONE SAMPLE SHALL BE COLLECTED FROM EACH DEAD END SEGMENT OF THE PIPELINES INSTALLED. IF BACTERIA OF ANY TIME IS FOUND, THE TEST SHALL BE REPEATED UNTIL THE LINES ARE CLEAN. BB. WATER MAIN SHALL HAVE 14 GA. BLUE COATED TRACER WIRE ON ALL SERVICES AND MAINS BURIED OVER THE WATER MAIN. CC. FIRE HYDRANTS SHALL BE PLACED A MINIMUM DISTANCE OF 6' BOC AND HAVE A CLEAR SPACE OF 3' FROM ANY PERMANENT STRUCTURES. DD. WATER VALVES SHALL COMPLY WITH APPROPRIATE AWWA STANDARDS. 1. GATE VALVES 2 -INCHES: SHALL CONFORM TO ANSI AWWA A21.11/C111 FOR CAST IRON BODIED BRONZE MOUNTED PARALLEL DOUBLE DISC, NON RISING STEM VALVES. VALVES SHALL BE RATED AT 200 PSIG WORKING PRESSURE AND 400 PSIG TEST PRESSURE. END CONNECTIONS SHALL BE STANDARD FEMALE IRON PIPE THREADS OR ANSI/AWWA A21.11 /C111 MECHANICAL JOINTS FOR BURIED LOCATIONS ADN ANSI 816.1 FLANGES FOR EXPOSED LOCATIONS. VALVE OPERATOR SHALL BE A 2 INCH SQUARE NUT FOR BURIED LOCATIONS AND STANDARD HANDWHEEL FOR EXPOSED LOCATIONS. ALL VALVES SHALL BE OPEN LEFT. 2. GATE VALVES 6 -INCHES THROUGH 16 -INCHES: SHALL CONFORM TO AWWA C509 FOR BRONZE MOUNTED, RESILIENT SEATED, CAST IRON BODIED GATE VALVES. VALVE BODY SHALL BE RATED FOR 200 PSIG WORKING PRESSURE AND 400 PSIG TEST PRESSURE. PROVIDE VALVE WITH SOLID WEDGE, NON RISING STEM CONSTRUCTION. VALVES SHALL EBE SEALED RUBBER "0" RING SEALS BOTH ABOVE AND BELOW THE THRUST RING. VALVES STEMS SHALL BE OF BRONZE. INTERIOR OF THE VALVES SHALL BE COATED IN ACCORDANCE WITH AWWA C550. END CONNECTIONS SHALL CONFORM TO ANSI/AWWA AS2.22/C111 MECHANICAL JOINTS FOR BURIED LOCATIONS AND ANSI B16.1 FLANGES FOR EXPOSED LOCATIONS. VALVE OPERATORS SHALL BE 2 INCH SQUARE NUTS FOR BURIED LOCATIONS OR STANDARD HANDWHEEL FOR EXPOSED LOCATIONS. ALL VALVES SHALL BE OPEN LEFT. IN LINE VALVES TO BE INSTALLED EVERY 2000 FEET OR EVERY OTHER HYDRANT. EE. WATER MAINS SHALL BE SUBJECT TO BOTH A PRESSURE TEST AND A LEAKAGE TEST. THE CONTRACTOR MAY BE BILLED FOR THE AMOUNT OF WATER USED. 1. PRESSURE TEST: SHALL CONFORM TO AWWA STANDARD C605 FOR PVC PIPE AND AWWA C600 FOR DUCTILE IRON. THE TEST PRESSURE SHALL BE 200 PSIG AND THE DURATION OF THE TEST SHALL BE NOT LESS THAN 2 HOURS OR MORE THAN 24 HOURS. THE DURATION OF THE TEST WILL BE DETERMINED BY THE COUNTY ENGINEER AS THE TEST PROGRESSES. PRESSURE SHALL NOT BE ALLOWED TO VARY MORE THAN 5 PSIG DURING THE TEST. 2. LEAKAGE TEST: SHALL BE CONDUCTED ALONG WITH THE PRESSURE TEST. LEAKAGE WILL BE DEFINED AS THE AMOUNT OF WATER THAT MUST BE SUPPLIED TO THE NEWLY LAID LINES TO MAINTAIN THE TEST PRESSURE WITHIN A 5 PSIG RANGE OVER A SPECIFIED PERIOD OF TIME. ALLOWABLE LEAKAGE WILL BE COMPUTED BY THE FOLLOWING FORMULA: L = (S) (D) (SQRT P) / 148,000 WHERE: L = ALLOWABLE LEAKAGE IN GALLONS PER HOUR S = LENGTH OF PIPE TESTED, IN FEET D = NOMINAL DIAMETER OF PIPE IN INCHES P = TEST PRESSURE IN PSIG BUT NOT MORE THAN: 12.1 GALLONS PER INCH OF DIAMETER PER MILE OF PIPE PER 24 HOURS BASED ON 200 PSI TEST PRESSURE. Lu rn 0 00 V_ U-) �I'1 J1 0 oM � m Z) m Li 0 uo co z m O WV k Q o Z m�M M 000 z � _ M OL m co z W U Q ® c W � - �1''� ui E m VW Z Z m U N � m IIIIIIIIIIIN '� Q ca N 3 z - m U v z 0 (i � - Z N = Z 10 m 00 c4 WW > z Q) C/) Q Q6m ma Lu 0) m Un o N Lu ct � 00 V_ U-) �I'1 J1 m � m Z) m W U z m O z m LLI 000 0 0 Y z (i -I J W CL QW J U cL u z T CL z oQLu C) J J m J (/) (,r) uj Q J u w wz� � o-Q� Q LL U W U z�� '11 I z W co ::) V N_ z Q O J J m Sheet C-5.8 ct � 00 V_ U-) �I'1 J1 °p °w � m Z) WL 1- O W U z m O z z 000 Y 0 (i Z) m ^' 0 w 0 vJ z z 0 (i -'O Y = >_ m Q C/) Q Z P Lu 0) m Un Sheet C-5.8