Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0021491_AtC Drawings_20180627
158 MOCKSVILLE LOCATION MAP TOWN OFFICIALS MAYOR COUNCIL MEMBERS NTERIM TOWN MANAGER PUBLIC WORKS DIRECTOR WILLIAM J. MARKLIN, III AMY VAUGHAN—JONES ERIC SOUTHERN ROB TAYLOR BRIAN WILLIAMS LEONARD BAREFOOT CONTRACT DRAWINGS WASTEWATER FACILITIES CONTRACT 11.0 DUTCHMAN'S CREEK WWTP RENOVATION CWSRF PROJECT NO. CS370606-02 TOWN OF MOCKSVILLE NORTH CAROLINA 0 UU11lis ENGINEERS FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION 27 JUNE 2018 ;� =_= SEAL 17 710 qRT HU� 1984.015 .: ry O Z W r_ O 1 ry Q U Li U g n U) Lu Y_ U) O O r - O U z cn ry Lu Lu z c� z Lu J J Q 27 JUNE 2018 CARD''% 04, o. :Q l^o SEAL •�= 17710 A• ,RT H�,.��`'� GENERAL: GENERAL NOTES: SCHEDULE OF MAJOR WORK ITEMS: G-1 M-1 SCHEDULES AND GENERAL NOTES HEADWORKS PLAN 7. UNLESS OTHERWISE NOTED, ALL MATERIAL SHALL BE G-2 EXISTING SITE PLAN 1. ALL WORK SHALL BE COORDINATED WITH THE ENGINEER AND 1. DEMOLISH EXISTING DRYING BED CONSTRUCT THICKENER FACILITY AND BLOWER SYSTEM. HEADWORKS SECTIONS THE PLANT STAFF. PLANT OPERATION AND PLANT ACCESS THE FOLLOWING SHALL BE THE GENERAL SEQUENCE OF M-3 E-5 G-3 ENLARGED PLAN AND DETAIL NEW SITE PLAN MUST BE MAINTAINED AT ALL TIMES. 2. REMOVE EXISTING SCREW SCREEN FROM INFLUENT PUMP STATION G-4 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY DEMO PLAN NORTH 2. INSTALLATION OF NEW EQUIPMENT AND STRUCTURES TO 3. INSTALL NEW HEADWORKS G-5 IDENTIFYING THE SEQUENCE AND DURATION OF EACH MAJOR WORK DEMO PLAN SOUTH MATCH THE ELEVATIONS OF THE EXISTING FACILITIES IS SLUDGE PUMPING PLAN AT GRADE BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. G-6 NEW PLAN NORTH CRITICAL. ELEVATIONS PROVIDED ON THE DRAWINGS SHALL 4. INSTALL NEW YARD PIPING M-6 SLUDGE PUMPING PLAN BELOW GRADE BE CONFIRMED AND CONVEYED ON APPROPRIATE SHOP ALL HOLES, TRENCHES AND OTHER HAZARDS SHALL BE M-7 G-7 SLUDGE PUMPING SECTIONS NEW PLAN SOUTH DRAWING SUBMITTALS. 5. INSTALL NEW CLARIFIERS G-8 GRADING PLAN NORTH 3. SIZE, LOCATION AND DEPTH OF BURIED UTILITIES SHOWN ARE 6. INSTALL NEW SLUDGE PUMP STATION G-9 GRADING PLAN SOUTH APPROXIMATE AND ARE SHOWN TO THE EXTENT POSSIBLE. SLUDGE THICKENING BELOW GRADE 10. G-10 POSSIBLE. HYDRAULIC PROFILE ROUTING OF NEW PIPING AND POTENTIAL CONFLICTS SHALL 7. INSTALL NEW ROTARY DRUM THICKENER FACILITY M-10 BE VERIFIED PRIOR TO BEGINNING CONSTRUCTION. WHERE ACTIVITIES ARE COMPLETED. 3. INSTALL NEW SPLITTER BOX. G-11 PROCESS DIAGRAM NECESSARY, POINTS OF CONNECTION TO EXISTING UTILITIES 8. INSTALL BLOWER SYSTEM AND AIR PIPING G-12 DIGESTER PLAN BELOW PLATFORM EROSION CONTROL DETAILS SHALL BE CONFIRMED PRIOR TO ORDERING OR FABRICATING 5. CONNECT AERATION BASINS TO NEW CLARIFIERS ONE AT A M-13 DIGESTER SECTIONS AND DETAILS NEW COMPONENTS. 9. INSTALL NEW SLUDGE DIGESTER 4. ALL OPENINGS IN PLANT PERIMETER FENCE SHALL BE CLOSED AND SECURED TO PREVENT ACCESS DURING NON—WORKING HOURS. 5. CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING FACILTIIES SCHEDULED TO REMAIN. 6. ALL MATERIAL GENERATED BY DEMOLITION, INCLUDING BUT NOT LIMITED TO, CONCRETE, REBAR, PROCESS EQUIPMENT, GRATING, HANDRAILS, PIPING AND ACCUMULATED GRIT AND SOLIDS SHALL BE PROPERLY DISPOSED OF BY THE CONTRACTOR. STRUCTURAL: S-1 HEADWORKS PLAN AND SECTION S-2 CLARIFIER PLAN AND SPLITTER BOX S-3 CLARIFIER SECTIONS S-4 SLUDGE PUMPING PLAN AND SECTIONS S-5 DIGESTER PLAN AND SECTIONS S-6 DETAILS MECHANICAL: 6. CONNECT NEW CLARIFIERS TO CHLORINE CONTACT BASINS. ELECTRICAL: 7. CONSTRUCT NEW HEADWORKS FACILITY. GENERAL CONSTRUCTION SEQUENCE: M-1 EXISTING SITE PLAN HEADWORKS PLAN 7. UNLESS OTHERWISE NOTED, ALL MATERIAL SHALL BE NEW SITE PLAN E-3 REMOVED FROM THE PROJECT SITE. NO CONSTRUCTION ENLARGED PLAN AND DETAIL M-2 CONSTRUCT THICKENER FACILITY AND BLOWER SYSTEM. HEADWORKS SECTIONS DEBRIS MAY BE BURIED OR LEFT ON SITE. THE FOLLOWING SHALL BE THE GENERAL SEQUENCE OF M-3 E-5 CLARIFIER PLAN AND SECTIONS ENLARGED PLAN AND DETAIL CONSTRUCTION. PRIOR TO BEGINNING WORK THE CONTRACTOR SHALL E-6 RISER DIAGRAM 8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY SUBMIT A DETAILED WRITTEN PROJECT SCHEDULE FOR APPROVAL M-4 CLARIFIER SECTIONS AND DETAILS ASSOCIATED WITH ALL REQUIREMENTS CURRENTLY MANDATED IDENTIFYING THE SEQUENCE AND DURATION OF EACH MAJOR WORK M-5 SLUDGE PUMPING PLAN AT GRADE BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. ITEM. ELECTRICAL WORK TO SUPPORT THE SEQUENCE OF CONSTRUCTION SHALL BE COMPLETED CONCURRENTLY. M-6 SLUDGE PUMPING PLAN BELOW GRADE 9. ALL HOLES, TRENCHES AND OTHER HAZARDS SHALL BE M-7 SLUDGE PUMPING SECTIONS ADEQUATELY PROTECTED BY BARRICADES OR OTHER 1. DEMOLISH SLUDGE DRYING BED. PROTECTIVE DEVICES AS REQUIRED. M-8 SLUDGE THICKENING AT GRADE 2. BUILD CLARIFIERS AND SLUDGE PUMP STATION TO EXTENT M-9 SLUDGE THICKENING BELOW GRADE 10. ACCESS DRIVEWAYS) FROM GARWOOD ROAD SHALL BE POSSIBLE. RESTORED TO THEIR INITIAL CONDITION ONCE CONSTRUCTION M-10 SLUDGE THICKENING SECTIONS AND ISOMETRIC ACTIVITIES ARE COMPLETED. 3. INSTALL NEW SPLITTER BOX. M-11 DIGESTER PLAN AT PLATFORM 4. INSTALL YARD PIPING TO EXTENT POSSIBLE. M-12 DIGESTER PLAN BELOW PLATFORM 5. CONNECT AERATION BASINS TO NEW CLARIFIERS ONE AT A M-13 DIGESTER SECTIONS AND DETAILS TIME. MAKE NEW RAS CONNECTIONS. M-14 BLOWERS PLAN, SECTION, AND DETAIL 6. CONNECT NEW CLARIFIERS TO CHLORINE CONTACT BASINS. ELECTRICAL: 7. CONSTRUCT NEW HEADWORKS FACILITY. E-1 EXISTING SITE PLAN 8. CONSTRUCT NEW DIGESTER. E-2 NEW SITE PLAN E-3 ENLARGED PLAN AND DETAIL 9. CONSTRUCT THICKENER FACILITY AND BLOWER SYSTEM. E-4 ENLARGED PLAN AND DETAIL 10. DEMOLISH UNDERGROUND SLUDGE PUMP STATION AS NEEDED. E-5 ENLARGED PLAN AND DETAIL E-6 RISER DIAGRAM O Z U_ J U z I N 00 N Q Z_ J ry U ry O Z Li r O ry Q U Li U g n U) w Y_ U) O O r - O U z ry w w z 0 z w U) J J Q 27 JUNE 2018 �cgRO''% FFSS%p :Q l° SEAL •�= 17710 ,RT H��,.��`', DUTCHMAN'S CREEK _ X X X X�X�X X X 21 FENCE x x 19 (@ ❑ x 04 x / x / I X � X / � O2 / x I X 3 I �X X � X l El 0 16S o O/ 7 x PROPERTY LINE I x 0-4 x cl M x u uU X o ❑ X�X�X—X� Lx— X ACCESS DRIVE TO GARWOOD ROAD SCHEDULE OF EXISTING FACILITIES O1 LAB AND I O2 AUXILIARY I i INFLUENT PUMP STATION l El 0 16S o O/ 7 x PROPERTY LINE I x 0-4 x cl M x u uU X o ❑ X�X�X—X� Lx— X ACCESS DRIVE TO GARWOOD ROAD SCHEDULE OF EXISTING FACILITIES O1 LAB AND ADMIN BUILDING O2 AUXILIARY POWER O3 INFLUENT PUMP STATION 40 CHEMICAL BUILDING O5 SPLITTER BOX © PARSHALL FLUME NO. 1 70 PARSHALL FLUME NO. 2 ® PARSHALL FLUME NO. 3 O AERATION BASIN NO. 1 10 AERATION BASIN NO. 2 11 AERATION BASIN NO. 3 12 CLARIFIER NO. 1 13 CLARIFIER NO. 2 14 CLARIFIER NO. 3 15 RAS/WAS PUMP STATION NO. 1 16 RAS/WAS PUMP STATION NO. 2 17 RAS/WAS PUMP STATION NO. 3 18 CHLORINE BUILDING 19 CHLORINE CONTACT BASIN NO. 1 20 CHLORINE CONTACT BASIN NO. 2 21 EFFLUENT SAMPLER 22 WAS FLOWMETER VAULT 23 AEROBIC DIGESTER 24 SLUDGE DRYING BED NOTES: 1. ITEMS SHOWN IN BOLD ARE TO BE REMOVED. O U_ J U Z I N 00 N Q z_ J ry U ry O z Li r O ry Q U Li U g n U) w Y_ U) O O r - O U z cn ry Lu Lu z c� z Lu J J Q 27 JUNE 2018 �cgRO''% F F SS % ptil :Q l^o SEAL •�= 17710 o. A• ,RTH11,1111110 ��,.��`', DUTCHMAN'S CREEK —VIEXISTING FENCE X _ x—,(—X---] ACCESS DRIVE TO GARWOOD ROAD 'ERTY LINE EW CONCRETE PAD ND SIDEWALK (TYP.) K-7 x I NEW FENCE x x qCo-4 X )RIVE (TYP.) NEW PROPERTY LINE SCHEDULE OF EXISTING FACILITIES O1 LAB AND ADMIN BUILDING O2 AUXILIARY POWER O3 INFLUENT PUMP STATION ® CHEMICAL BUILDING © PARSHALL FLUME NO. 1 70 PARSHALL FLUME NO. 2 ® PARSHALL FLUME NO. 3 O9 AERATION BASIN NO. 1 10 AERATION BASIN NO. 2 11 AERATION BASIN NO. 3 16 RAS/WAS PUMP STATION NO. 2 17 RAS/WAS PUMP STATION NO. 3 18 CHLORINE BUILDING 19 CHLORINE CONTACT BASIN NO. 1 20 CHLORINE CONTACT BASIN NO. 2 21 EFFLUENT SAMPLER 22 WAS FLOWMETER VAULT 23 AEROBIC DIGESTER SCHEDULE OF NEW FACILITIES OA HEADWORKS © SPLITTER BOX © CLARIFIER NO. 1 OD CLARIFIER NO. 2 OE SLUDGE PUMP STATION OF SLUDGE THICKENING BUILDING © AEROBIC DIGESTER OH DIGESTER BLOWERS NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. ss 27 JUNE 2018 CARO''% %04, :Q l^o SEAL •�= 17710 RTH6�,.��`', cn cn 0 27" PVC SANITARY SEWER INFLUENT NOTES: 1. ITEMS SHOWN IN BOLD ARE TO BE REMOVED OR ABANDONED. 2. CONTRACTOR SHALL TAKE CAUTION TO AVOID DAMAGING EXISTING ITEMS SCHEDULED TO REMAIN AS LISTED ON THIS SHEET. THE CONTRACTOR co SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING ITEMS THAT ARE SCHEDULED TO REMAIN. 3. ALL EXISTING PUMPS' PIPING AND APPURTENANT HARDWARE AND 14" EFFLUENT PIPE TO SUPPORTS SHALL BEDISCONNECTED AND REMOVED FROM CLARIFIERS, DUTCHMAN'S CREEK X X X X X X X WET WELLS AND VALVE VAULTS. ss X ss— s= X 7 s X X X x 4. ALL OTHER ELECTRICAL AND MECHANICAL EQUIPMENT SHALL BE X X � X X X ss ss DISCONNECTED AND REMOVED AS NOTED. I ss ss 04 12 x ml x w o STORAGE BUILDING TO REMAIN SIDEWALK TO BE REMOVED CLARIFIER NO. 1 TO BE REMOVED EXISTING DRIVE TO BE REMOVE UNDERGROUND RAS/WAS PUMP STATION TO BE REMOVED 0 7T OE — -- o� w w w /�-� 7 /,,--1 L7_ FM 10" AERATION 6" RETURN BASIN SLUDGE LINE. EFFLUENT SEE NOTE 9. PIPE (TYP). SEE NOTE 9. AERATION BASIN NO. 1 < :E: SLUDGE DRYING BEDS TO BE REMOVED w -Ti _Tl m :�__ 10" CLARIFIER EFFLUENT PIPING TO BE REMOVED PORTION OF SIDEWALK TO BE REMOVED (TYP.) .w RAS/WAS PUMP BUILDING TO REMAIN. SEE NOTE 14. CLARIFIER NO. 2 TO BE REMOVED W 0 `SLRETURN UDGE NE. SCUM PIT AND REMOVE TO VALVE VAULT TO FITTING. BE REMOVED. SEE NOTES 8 AND 10. PORTION OF EXISTING RETURN SLUDGE LINE TO BE REUSED. -Ti � AERATION BASIN NO. 2 `6" RETURN SLUDGE LINE TO -i _T BE PLUGGED AND ABANDONED. SEE NOTE 6. 0 w 10 3 3 111 3 II w 0 EXISTING / CHLORINE BUILDING i TO REMAIN 12. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AND SEED AND MULCH ALL DISTURBED AREAS. RAS/WAS PUMP 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ITEMS BUILDING TO REMAIN. SCHEDULED TO REMAIN. SEE NOTE 14. 14. NOTED STRUCTURES ARE TO HAVE MECHANICAL EQUIPMENT REMOVED AND x ALL PIPING CONNECTIONS PLUGGED. 6" WASTE SLUDGE LINE. REMOVE TO CLARIFIER NO. 3 FITTING. TO REMAIN. SEE NOTE 14. 6" RETURN SLUDGE LINE. REMOVE TO LOCATION SHOWN w w ttyl FM —T❑( FM A. REMOVE PIPE TO FITTING AND PLUG. AERATION BASIN NO. 3 X�-6" RETURN SLUDGE LINE TO BE PLUGGED AND ABANDONED. SEE NOTE 6. x XISTING PLUG VALVE x PORTION OF EXISTING WASTE < _n � SLUDGE LINE TO BE REUSED. T, - �� rl x PORTION OF ,-i EXISTING RETURN SLUDGE LINE TO BE REUSED. x -71 EXISTING FLOW METER TO REMAIN EXISTING FENCE x TO BE REMOVED IN CHARGE CAWjr 20' 0 20' 40' FINAL DRAWING DUTCHMAN'S CREEK WWTP RENOVATION 1984.015 DESIGNED SEG TOWN OF MOCKSVILLE FOR REVIEW PURPOSES ONLY lmilliSENGINEERS G-4.DWG MADE BY SEG WASTEWATER FACILITIES DEMO P LA N NORTH CHECKED GJw NOT RELEASED FOR CONSTRUCTION JUNE 2018 G-4 5. ALL ABOVE GRADE PIPING VALVES AND OTHER APPURTENANCES SHALL Or- EREMOVED REMOVEDAS NOTED. BELOW GRADE PIPING DEEPER THAN 3' SHALL BE x ABANDONED IN PLACE. 6. ABANDONMENT OF THE EXISTING FORCE MAINS SHALL CONSIST OF DRAINING THE CONTENTS OF THE FORCE MAIN, REMOVING THE FORCE MAIN FROM SERVICE, FLUSHING THE FORCE MAIN WITH WATER AND PLUGGING ALL OPENINGS WITH GROUT. THE GROUT PLUGS SHALL EXTEND x AT LEAST 2' INSIDE THE FORCE MAIN TO PROVIDE A WATERTIGHT SEAL. CHLORINE CHLORINE CONTACT CONTACT 7. THE SLUDGE DRYING BED SHALL BE REMOVED IN ITS ENTIRETY. BASIN BASIN NO. 1 NO 2 8. ALL FOUNDATIONS, BELOW—GRADE CONSTRUCTION AND CONCRETE SLABS x SHALL BE DEMOLISHED AND REMOVED TO A DEPTH OF 3' BELOW GRADE. 9. PIPING TO BE SAW CUT TO ALLOW NEW CONNECTION AT THIS POINT. 10. UPON COMPLETION OF DEMOLITION WORK THE CONTRACTOR SHALL FILL x ABANDONED WET WELLS AND VALVE VAULT WITH LOW STRENGTH GROUT. 3 CLARIFIERS SHALL BE FILLED WITH STONE. PRIOR TO FILLING, BELOW GRADE AREAS AND VOIDS SHALL BE FREE OF STANDING WATER, TRASH AND DEBRIS. 12" PIPE. 11. ALL MATERIALS FROM DEMOLITION WORK SHALL BECOME PROPERTY OF REMOVE / x THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AND s TO FITTING. i PROPERLY DISPOSED OF IMMEDIATELY. SIDEWALK TO REMAIN `SLRETURN UDGE NE. SCUM PIT AND REMOVE TO VALVE VAULT TO FITTING. BE REMOVED. SEE NOTES 8 AND 10. PORTION OF EXISTING RETURN SLUDGE LINE TO BE REUSED. -Ti � AERATION BASIN NO. 2 `6" RETURN SLUDGE LINE TO -i _T BE PLUGGED AND ABANDONED. SEE NOTE 6. 0 w 10 3 3 111 3 II w 0 EXISTING / CHLORINE BUILDING i TO REMAIN 12. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AND SEED AND MULCH ALL DISTURBED AREAS. RAS/WAS PUMP 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ITEMS BUILDING TO REMAIN. SCHEDULED TO REMAIN. SEE NOTE 14. 14. NOTED STRUCTURES ARE TO HAVE MECHANICAL EQUIPMENT REMOVED AND x ALL PIPING CONNECTIONS PLUGGED. 6" WASTE SLUDGE LINE. REMOVE TO CLARIFIER NO. 3 FITTING. TO REMAIN. SEE NOTE 14. 6" RETURN SLUDGE LINE. REMOVE TO LOCATION SHOWN w w ttyl FM —T❑( FM A. REMOVE PIPE TO FITTING AND PLUG. AERATION BASIN NO. 3 X�-6" RETURN SLUDGE LINE TO BE PLUGGED AND ABANDONED. SEE NOTE 6. x XISTING PLUG VALVE x PORTION OF EXISTING WASTE < _n � SLUDGE LINE TO BE REUSED. T, - �� rl x PORTION OF ,-i EXISTING RETURN SLUDGE LINE TO BE REUSED. x -71 EXISTING FLOW METER TO REMAIN EXISTING FENCE x TO BE REMOVED IN CHARGE CAWjr 20' 0 20' 40' FINAL DRAWING DUTCHMAN'S CREEK WWTP RENOVATION 1984.015 DESIGNED SEG TOWN OF MOCKSVILLE FOR REVIEW PURPOSES ONLY lmilliSENGINEERS G-4.DWG MADE BY SEG WASTEWATER FACILITIES DEMO P LA N NORTH CHECKED GJw NOT RELEASED FOR CONSTRUCTION JUNE 2018 G-4 O z U_ J U Z I N 00 N Q z_ J O ry Q U ry O z w O J ry Q U w U g n U) w Y U) O O O U z ry w w z 0 z w U) J J Q cn co U) 3 X AERATION BASIN NO. 1 8 w O LL ri AERATION BASIN NO. 2 c I AERATION BASIN NO. 3 T -71 6" WAS FORCE --, MAIN TO BE < REMOVED TO 3 o w ly THIS POINT. K -n � I 00 I N u cI � E 110 EXISTING I FM X PARSHALL FLUME X FLUME 1 co I /X ElX I I cn cn x I I 8" DIP TO BE I o ABANDONDED TO THIS POINT. ---- 10 OINT. 10" DIP TO BE REMOVED TO THIS II w POINT. SEE NOTE 2. J OE EXISTING PARSHALL FLUME 2 ,-, . —� W w VU W� W� 3 w N ------- SS I EXISTING PARSHALL DIGESTER FLUME 3 - V) cn co U) 3 X AERATION BASIN NO. 1 8 w O LL ri AERATION BASIN NO. 2 c I AERATION BASIN NO. 3 T -71 6" WAS FORCE --, MAIN TO BE < REMOVED TO 3 o w ly THIS POINT. K -n � I 00 I N u cI � E 110 EXISTING I FM X PARSHALL FLUME X FLUME 1 co I /X ElX I I cn cn x I I 8" DIP TO BE I o ABANDONDED TO THIS POINT. ---- 10 OINT. 10" DIP TO BE REMOVED TO THIS II w POINT. SEE NOTE 2. J OE EXISTING PARSHALL FLUME 2 ,-, . —� W w VU W� W� 3 w --- I ------- EXISTING I EXISTING PARSHALL DIGESTER FLUME 3 - DECANT TO BE EXISTING ABANDONED. 10" DIPS --710" DIP TO BE REMOVED TO THIS I POINT. SEE NOTE 2. EXISTING AEROBIC DIGESTER VALVES TO BE CLOSED EXISTING 8" X X ON F-14 x x Pm �SLUDGE DRAIN x x REMOVE SCREW EXISTING 10" DIP SCREEN FROM WET WELL FM FM — fi— FM FM I REMOVE AERATOR FM FM EXISTING DISCONNECT AND FM FM FM SPLITTER TO EXISTING STAIRS CONTROL PANEL x FMS FM FEU M FM F1V1u v • O , , — — BE REMOVED AND PLATFORM — X — X EXISTING w w �„�-- ——�X�X 12" DIP — EXISTING CHEMICAL FEED X X FORCE MAIN — X X �— X X —X—X—XX X X X�X _ X X X X X ' 27 JUNE 2018 �cgRO''% FF SS%ptil �— :Q l^ SEAL •�= 17710 o. A• %,,,RT H��,.��`', PORTION OF EXISTING 12" FORCE MAIN TO BE REMOVED. SEE NOTE 2. EXISTING 6" SLUDGE HAULING CONNECTION TO BE RECONNECTED TO NEW PIPING— EXISTING 8" SLUDGE DRAIN 6" MJ ELBOW TO BE REMOVED. SEE SHEET G-6 FOR NEW SLUDGE DRAIN CONNECTION DETAIL. FILL WITH GROUT AND ABANDON (TYP. 6" RETURN SLUDGE LINE TO BE PLUGGED AND ABANDONED. SEE NOTE 3. NOTES: 1. ITEMS SHOWN IN BOLD ARE TO BE REMOVED OR ABANDONED AS NOTED. 2. PIPING TO BE SAW CUT TO ALLOW NEW PIPING CONNECTION AT THIS POINT. 3. ABANDONMENT OF THE EXISTING FORCE MAINS SHALL CONSIST OF DRAINING THE CONTENTS OF THE FORCE MAIN, REMOVING THE FORCE MAIN FROM SERVICE, FLUSHING THE FORCE MAIN WITH WATER AND PLUGGING ALL OPENINGS WITH CEMENT GROUT. THE CEMENT PLUGS SHALL BE SET TO EXTEND AT LEAST 2' INSIDE THE FORCE MAIN TO PROVIDE A WATERTIGHT SEAL. EXISTING FENCE TO BE REMOVED TEMPORARY AERATION SYSTEM TO BE REMOVED. BLOWER TO BE REINSTALLED AT CHLORINE CONTACT CHAMBER - EXISTING DECANT PIPING TO BE CUT AND REMOVED AT FLOOR GEVEL.FILLBURIED PIPING WITH ROUT. PROVIDE WATERTIGHT SEAL (TYP.) 8" SLUDGE DRAIN TO REMAIN AEROBIC DIGESTER DEMO DETAIL PORTION OF WAS FORCE MAIN TO REMAIN WAS FORCE MAIN TO BE REMOVED TO EXTENTS SHOWN ON DEMO SITE PLAN. V ■ O Z U_ J U Z I N 00 N Q Z_ J O ry Q U ry O Z Li r O 1 ry Q U Li U g n U) W Y U) O O r - O U Z ry w w Z 0 Z w U) J J Q CORE INTO EXISTING MANHOLE. SEE NOTE 5. 27 JUNE 2018 CARO''% %o*:Q l^ SEAL •�= 17710 ,RT H�,.��`', 10, NEW 1 CLARIFII 27" PVC SAN ITA SEWER INFLUEN' N TI SS U) 0 U) m U) i ■■■■■■■■■■■■■■■ ■■■ 20W�IDIP OI a- a - a E E AERATION BASIN NO. 2 3 3 w FM 4 FM AERATION BASIN NO. 3 T, NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. 2. NEW PRESSURE PIPING SHALL CONNECT TO EXISTING PIPING VIA THE APPROPRIATE MJ FITTING AND RESTRAINT. 'MEGA—LUG' TYPE ASSEMBLIES ARE PERMITTED. 3. NEW 20" DIAMETER CLARIFIER EFFLUENT PIPING SHALL CONNECT TO THE EXISTING 12" DIAMETER CHLORINE CONTACT INFLUENT VIA 20" X 12" MJ REDUCER, 12" MJ PLUG VALVE, 12" DIP, AND 12" SOLID SLEEVE COUPLING. 4. PROCESS VALVING NOT SHOWN FOR SLUDGE PUMP STATION ON THIS SHEET. 5. NEW 12" DRAIN TO MAINTAIN NEGATIVE SLOPE TO EXISTING MANHOLE. CONTRACTOR SHALL CORE THROUGH WALL AT MANHOLE. LINK SEALS TO BE PROVIDED ON WALL INTERIOR. INVERT IN ELEVATION OF 12" SEWER DRAIN SHALL BE AT 643.00. 6. PREVIOUSLY ABANDONED AND ABANDONED PIPING AS PART OF THIS CONTRACT NOT SHOWN FOR CLARITY. 7. NEW YARD HYDRANTS FOR THIS CONTRACT SHALL BE 1" FREEZELESS YARD HYDRANTS. x > ONNECT TO XISTING 6" WAS IPING. SEE NOTE 2. x 012 ONNECT NEW 6" RAS FORCE MAIN TO EXISTING 6" PIPING. SEE NOTE 2 X 0 x TI 0 AERATION BASIN NO. 2 3 3 w FM 4 FM AERATION BASIN NO. 3 T, NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. 2. NEW PRESSURE PIPING SHALL CONNECT TO EXISTING PIPING VIA THE APPROPRIATE MJ FITTING AND RESTRAINT. 'MEGA—LUG' TYPE ASSEMBLIES ARE PERMITTED. 3. NEW 20" DIAMETER CLARIFIER EFFLUENT PIPING SHALL CONNECT TO THE EXISTING 12" DIAMETER CHLORINE CONTACT INFLUENT VIA 20" X 12" MJ REDUCER, 12" MJ PLUG VALVE, 12" DIP, AND 12" SOLID SLEEVE COUPLING. 4. PROCESS VALVING NOT SHOWN FOR SLUDGE PUMP STATION ON THIS SHEET. 5. NEW 12" DRAIN TO MAINTAIN NEGATIVE SLOPE TO EXISTING MANHOLE. CONTRACTOR SHALL CORE THROUGH WALL AT MANHOLE. LINK SEALS TO BE PROVIDED ON WALL INTERIOR. INVERT IN ELEVATION OF 12" SEWER DRAIN SHALL BE AT 643.00. 6. PREVIOUSLY ABANDONED AND ABANDONED PIPING AS PART OF THIS CONTRACT NOT SHOWN FOR CLARITY. 7. NEW YARD HYDRANTS FOR THIS CONTRACT SHALL BE 1" FREEZELESS YARD HYDRANTS. x > ONNECT TO XISTING 6" WAS IPING. SEE NOTE 2. x 012 ONNECT NEW 6" RAS FORCE MAIN TO EXISTING 6" PIPING. SEE NOTE 2 X 0 x O U_ J U Z I N 00 N Q z J O ry Q U ry O z w r O J ry Q U Li U g n U) w Y_ U) O O O U z ry w w z c� z w U) J J Q 3 X L c x 3 X x 3 8 Y 0E 10 N X X / X / X N 0 x ° ssss ss ss ss ss X EXISTING 10 DIP CORE THROUGH WALL. SEE NOTE 3. FM FM FM FM O X FNS FM FM F �w O EXISTING w 12 DIP FORCEMAIN ° —X—X—X—X�X�X�XX�, 27 JUNE 2018 CARO''% 104' Q l° : SEAL •�= 17710 A• ,RTH1111111110 ��,.��`', Iq a -Ti W 0 AERATION BASIN NO. 2 0 3 ,��EXISTING FENCE 1 < EXISTING 6" WAS FORCE x MAIN AERATION BASIN NO. 3 X EXISTING 6" WAS FLOW X METERING VAULT NEW 6" WAS FORCE MAIN .X X X X� x NEW SLUDGE THICKENING BLDG. SEE SHEET M-8 THROUGH M-10. -ss II 3 X L c x 3 X x 3 8 Y 0E 10 N X X / X / X N 0 x ° ssss ss ss ss ss X EXISTING 10 DIP CORE THROUGH WALL. SEE NOTE 3. FM FM FM FM O X FNS FM FM F �w O EXISTING w 12 DIP FORCEMAIN ° —X—X—X—X�X�X�XX�, 27 JUNE 2018 CARO''% 104' Q l° : SEAL •�= 17710 A• ,RTH1111111110 ��,.��`', Iq a -Ti W 0 AERATION BASIN NO. 2 0 3 ,��EXISTING FENCE 1 < EXISTING 6" WAS FORCE x MAIN AERATION BASIN NO. 3 X EXISTING 6" WAS FLOW X METERING VAULT NEW 6" WAS FORCE MAIN .X X X X� x NEW SLUDGE THICKENING BLDG. SEE SHEET M-8 THROUGH M-10. NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. 2. PREVIOUSLY ABANDONED AND ABANDONED PIPING AS PART OF THIS CONTRACT NOT SHOWN FOR CLARITY. 3. NEW 8" SEWER TO MAINTAIN NEGATIVE SLOPE TO INFLUENT PUMP STATION. CONTRACTOR SHALL CORE THROUGH WALL FOR 8" SEWER. LINK SEALS TO BE PROVIDED ON WALL INTERIOR. INVERT IN ELEVATION OF 8" SEWER PIPE SHALL BE AT 655.45. 4. NEW 12" DIP PIPE TO CONNECT TO EXISTING 10" DIP PIPE VIA 12" X 10" MJ 90• BEND. EXISTING 6" SLUDGE HAULING CONNECTION TO BE RECONNECTED TO NEW PIPE - EXISTING 8"X6" MJ TEE - UO NEW 6" MJ TEE - 0 NEW BLOWER X PAD. SEE SHEET M-14. I 0 x SEE SHEET M-11 THROUGH M-13. x x X__1 NEW FENCE NEW EXTENDED VALVE STEM, NUT, AND ROAD BOX NEW 8" DIP FROM NEW AEROBIC DIGESTER NEW 8"X6" NEW 6" MJ MJ REDUCER PLUG VALVE SLUDGE DRAIN CONNECTION DETAIL II AI Y _71 SLUDGE 'dy -Y 0 E THICKENING H w w BUILDING � of - of -� p Wj -EXISTING I EXISTING EXISTING NEW 2" PARSHALL PARSHALL PARSHALL WATER FLUME 1 I I l FLUME 2 w FLUME 3 NEW 8» ® I ® NEW 8" AIR PIPING I I DRAIN NEW I EXISTING 6" AIR NEW NEW 8"X8"X6" AEROBIC PIPING AEROBIC I WYE FOR NEW DIGESTER (TYP.) DIGESTER DRAIN FROM EXISTING I EXISTING HEADWORKS 10" DIP 8" DIP EXISTING 10" DIP ss NEW 8 DIP :....: . :. i' -� ,.;........:' , , . ; ::_.: �: NEW 8 SLUDGE SANITARY SEWER. SEE NOTE 3.---/::...... I ::.:.::.; •.:•,:..•..'.'.:....::::....... .. ... __] NEW 12 DIP. ;::..:....:.:.: :`.'::::; ..;; DRAIN I - SEE NOTE 4. I a. FM FM TFM —fi— F FM I � I ,°. , SEE THIS SHEET OR SLUDGE DRAIN ;.:. :'. ... NEW 8 <. DRAIN D CONNECTION DETAIL w FM M ' EXISTING CHEMICAL FEED /NEW NEW YARD NEW 12" DIP HYDRANT (TYP.) NEW ASPHALT DRIVE FORCE MAIN NEW 2" HEADWORKS. _ ENTRANCE X X X X WATER SEE SHEET M-1 X-----�X-----X X X X X X X X X X X X NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. 2. PREVIOUSLY ABANDONED AND ABANDONED PIPING AS PART OF THIS CONTRACT NOT SHOWN FOR CLARITY. 3. NEW 8" SEWER TO MAINTAIN NEGATIVE SLOPE TO INFLUENT PUMP STATION. CONTRACTOR SHALL CORE THROUGH WALL FOR 8" SEWER. LINK SEALS TO BE PROVIDED ON WALL INTERIOR. INVERT IN ELEVATION OF 8" SEWER PIPE SHALL BE AT 655.45. 4. NEW 12" DIP PIPE TO CONNECT TO EXISTING 10" DIP PIPE VIA 12" X 10" MJ 90• BEND. EXISTING 6" SLUDGE HAULING CONNECTION TO BE RECONNECTED TO NEW PIPE - EXISTING 8"X6" MJ TEE - UO NEW 6" MJ TEE - 0 NEW BLOWER X PAD. SEE SHEET M-14. I 0 x SEE SHEET M-11 THROUGH M-13. x x X__1 NEW FENCE NEW EXTENDED VALVE STEM, NUT, AND ROAD BOX NEW 8" DIP FROM NEW AEROBIC DIGESTER NEW 8"X6" NEW 6" MJ MJ REDUCER PLUG VALVE SLUDGE DRAIN CONNECTION DETAIL d C L� L c L I r r ON oc CISa L C Q! a c.: Q! c L L r C 4 7 c L c 4 a U L v c c r C U a L L L L L L F XX XX XX I Ix x MANHOLE XX _ _XX _ XX LIMITS OF DISTURBANCE EXISTING TREE LINE 27 JUNE 2018 ,,,•o��� CARp :Q l: =_= SEAL 17710 FJ''F�� I...... qR T H 6 ��,•�`��. ��1J Ttls 1f1�=rJ / SILT FENCE (TYP.) I Ix x II IX I� X x MANHOLE OPTIONAL STAGING AREA PROTECTION — — � 12' / I I �6`------------ x �— —6 6-5 x---------- X— I II I ►1 / I I I D X X NOTES: x x x 1. NEW ASPHALT DRIVE SHALL BE A MINIMUM OF 8" ABC STONE WITH 2" OF 1-2. x X X X � --- X X D X X NOTES: x x x 1. NEW ASPHALT DRIVE SHALL BE A MINIMUM OF 8" ABC STONE WITH 2" OF 1-2. x X X X � --- X X 0 N 00 N ry O z w r- 0 ry Q U U) Lu Y_ U) U z cn ry Lu Lu z c� z Lu x x I EXISTING MANHOLE OPTIONAL STAGING AREA x , I SILT FENCE (TYP.) X> \ Ix/ `O/ \ X\--x—�x 27 JUNE 2018 cqRo''% FFSS/p :Q l^ SEAL •�= 17710 ,RT H�\,.��`', END OF ASPHALT DRIVE TEMPORARY CONSTRUCTION ENTRANCE EXISTING GRAVEL DRIVE FROM GARWOOD ROAD— NEW ASPHALT DRIVE. SEE NOTE 2. 31rCh1VV VV/AI ILC lI Ir'.)- ---------------- T-----�--T-7---I------7------7- ---a7Q-----L- --- ----- -----�---------, // --- / X XIX X X X X X 671 I --I-- �� / 672------�------�— \ NEW FENCE DITCH LINE. SEE NOTE 1. /------- 673 --- ------\--------7 - - — — / I \LIMITS OF DISTURBANCE � —/— �--I---�--�--- � I I -- --- ---- -- I I I � I I I I I I I I NOTES: 1. ALL SLOPES AND DITCHES SHALL BE RESTORED WITH EXCELSIOR MATTING. REFER TO DETAIL OR NOTE ON SHEET G-12. 2. NEW ASPHALT DRIVE SHALL BE A MINIMUM OF 8" ABC STONE WITH 2" OF 1-2. \ x x 1 x I I I x , I SILT FENCE (TYP.) X> \ Ix/ `O/ \ X\--x—�x 27 JUNE 2018 cqRo''% FFSS/p :Q l^ SEAL •�= 17710 ,RT H�\,.��`', END OF ASPHALT DRIVE TEMPORARY CONSTRUCTION ENTRANCE EXISTING GRAVEL DRIVE FROM GARWOOD ROAD— NEW ASPHALT DRIVE. SEE NOTE 2. 31rCh1VV VV/AI ILC lI Ir'.)- ---------------- T-----�--T-7---I------7------7- ---a7Q-----L- --- ----- -----�---------, // --- / X XIX X X X X X 671 I --I-- �� / 672------�------�— \ NEW FENCE DITCH LINE. SEE NOTE 1. /------- 673 --- ------\--------7 - - — — / I \LIMITS OF DISTURBANCE � —/— �--I---�--�--- � I I -- --- ---- -- I I I � I I I I I I I I NOTES: 1. ALL SLOPES AND DITCHES SHALL BE RESTORED WITH EXCELSIOR MATTING. REFER TO DETAIL OR NOTE ON SHEET G-12. 2. NEW ASPHALT DRIVE SHALL BE A MINIMUM OF 8" ABC STONE WITH 2" OF 1-2. Li r_ O J Q U W U g cn Lu Y_ U z cn Lu Lu z CD Z Lu HGL AT PEAK FLOW (3.43 MGD) WITH 1.0 RECYCLE RATIO OF DESIGN FLOW (ONE CLARIFIER IN SERVICE) HGL AT AVERAGE DESIGN FLOW (0.98 --------- MGD) WITH 1.0 RECYCLE RATIO OF DESIGN FLOW (ALL UNITS IN SERVICE) 680 680 679.07 678 678 676 676 674 674 673.70 \ 672 \ 672 \ \ \ \ 670.32 670 670 670.14 668.00 668 668 666.99 -------------_ 100 YR 666 666.59 666.49 FLOOD ELEV 666 665.70 664.67 664.57 664 664 -------------------------- --___ 663.14 663.53 663.52 ------____------------ 662.73 661.86 661.63 662 662 661.56 -------------------- - - - - - - - - - - - - - - - - - - - 661.54 660.72 660.08 660 660 659.89-`_____ 59.89 659.8517�7 - - - 659.45 658.33 658 658 STATIC LL TOW 675.00 670.00 HEADWORKS STATIC LL 662.42 TOW 666.50 STATIC LL TOW 661.00 12 -INCH PARSHALL ----------_ - - - - - - - -- TOW 665.00 662.50 TOW 663.50 STATIC LL 661.50 STATIC LL 659.27 TOW 662.36 G,Z, FLUME AERATION 10 -INCH T BASINS _ INC2-INFLUENT H PUMI �,�\� '� CLARIFIERS 12 -INCH -INCH STATI O N I SPLITTER 15 -INCH CHLORINE CONTACT BASIN BOX HWL 637.72 LWL 630.85 27 JUNE 2018 CARO''% :Q l^ SEAL 17710 =�F NG I NF; ���� T ,.� uu1111 IN CHARGE CAWjr FINAL DRAWING DUTCHMAN'S CREEK WWTP RENOVATION 19 84.015 2 0 2 4 TOWN OF MOCKSVILLE '11iiinv11\``````` DESIGNED SEG G-10.DWG G-10 FOR REVIEW PURPOSES ONLY IIUIIIISENGINEERS MADE BY SEG WASTEWATER FACILITIES HYDRAULIC PROFILE (,f/ NOT RELEASED FOR CONSTRUCTION CHECKED GJw JUNE 2018 O U_ J U Z I N 00 N Q Z_ J 0 ry U ry O w 0 J ry Q U w U g n U) Lu Y_ U) 0 O r- 0 U z ry w w z cD z Lu U) J J Q I \ I \ I \ \ I \ I \ I \ n2 \\ - ----------------- 11,� n 20" PROCESS b NR_ no z Lu D J LL_ LL_ w N .............. z w D J LL_ LL_ w O3T 10 6" THICKENED SLUDGE 12 12 12 20" PROCESS rn c: I O U) � I N I a O �O CO I 6" RAS T 6" AIR I 81 I I I I I I I I I I I� ® — z 1- I I I I I I I 8" DECANTI I I I 6" RAS ~�------L-----A I �------T. --- I 8" SLUDGE DRAIN L— T I 6" SLUDGE WITHDRAWAL — — — — — — — — — — — -------- 8" DRAIN I L---------------------------------------~-----------------------------------------------------------------I 27 JUNE 2018 �cgRO''% pec ESS %pal �- :Q l^ SEALo •�= °: 17710 ,lFso. A• ,RTH1111111110 ��,.��`'� - wA� SYMBOL LEGEND GATE VALVE b PLUG VALVE LTJ N BUTTERFLY VALVE g BALL VALVE O FLOW METER TELESCOPING VALVE PUMP T DIFFUSER AIR PIPING LEGEND SEWER/DRAIN PROCESS RAS WAS AIR CHEMICAL FEED ..........SAMPLING NOTES: 1. THE FLOW DIAGRAM REPRESENTS POST CONSTRUCTION PLANT LAYOUT AND DOES NOT DISTINGUISH BETWEEN NEW AND EXISTING COMPONENTS. 2. NOT ALL VALVES ARE SHOWN. ONLY VALVES FOR PROCESS ISOLATION ARE SHOWN. z w J L.� w w Ln TREATMENT / EQUIPMENT LEGEND O1 INFLUENT PUMP STATION QUANTITY: 3 PUMPS CAPACITY: 1,150 GPM, EACH O2 HEADWORKS SCREENING MECHANICAL RAKE QUANTITY: 1 OPENING SIZE: 6 MM MANUAL QUANTITY: 1 BAR SPACING: 1 -INCH O3 PARSHALL FLUME ® AERATION BASINS QUANTITY: 3 CAPACITY: 340,000 GAL AERATORS: 2 ® 25 HP, EACH O5 SPLITTER BOX © CLARIFIERS QUANTITY: 2 CAPACITY: 296,000 GAL, EACH O7 CHLORINE DISINFECTION QUANTITY: 2 CAPACITY: 37,400 GAL, EACH ® SLUDGE PUMPING RAS QUANTITY: 4 CAPACITY: 230 GPM, EACH WAS QUANTITY: 2 CAPACITY: 125 GPM, EACH O9 SCUM PUMPING QUANTITY: 2 CAPACITY: 122 GPM 10 SLUDGE THICKENING QUANTITY: 1 CAPACITY: 150 GPM 11 AEROBIC DIGESTION QUANTITY: 2 VOL. NEW: 254,000 GAL VOL. OLD: 176,000 GAL 12 BLOWERS QUANTITY: 3 CAPACITY: 516 SCFM, EACH O z (.3_ J U z I N 00 N Q Z_ J O ry Q U ry O z Li r O 1 ry Q U Li U g n U) w Y U) O O r - O U z ry w w z CD z w U) J J Q a' -n" KAAY c,TrrL T -POST /LINEAR FT AUGE HARDWARE H WITH 1/4" 1 OPENINGS JCDOT #5 OR #57 MASHED STONE ?:1 SLOPE AWAY II U NOTES: 1. CONTRACTOR MAY USE BLOCK AND GRAVEL INLET PROTECTION IN ACCORDANCE WITH EROSION CONTROL DETAIL 6.52 IN LIEU OF WOVEN MESH PROTECTION. 2. INSPECT INLET PROTECTION WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. CLEAN OUT SEDIMENT AND REPLACE STONE AS NEEDED TO MAINTAIN INLET PROTECTION AS SPECIFIED. U DROP INLET PROTECTION CONFORMS TO EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL DETAIL 6.51 \A/CID I C-1WITU /A'\ STONE ON J.UPSTREAM FACE OF OUTLET PLAN 27 JUNE 2018 CARO''% 104**, :Q l^ SEAL •�= 17710 TH��,.��`', ' — — I- lU -1 Al ULN I LK r r-1v%_.r- SECTION ALONG FENCE 18" CLASS B EROSION SILT CHECK CONTROL STONE FENCE POST FLOW - - - - 12" OF NO. 57 o 18" AT CENTER WASHED STONE FILTER FABRIC SECTION THROUGH STONE OUTLET NOTES: 1. INSPECT STONE OUTLETS WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. REMOVE SEDIMENT ACCUMULATED BEHIND OUTLET AND RESTORE STONE AS REQUIRED. STONE OUTLET DETAIL FILTER FABRIC WITHWIRr rrkinikin 8' -Off (MAX.) FILTER FABRIC WIRE FENCING - N I 00 STEEL POST EXTEND FABRIC AND WIRE INTO TRENCH AND BACKFILL WITH COMPACTED SOIL PLASTIC OR WIRE TIES 8*0 8" 0 I N Ll NOTES: 1. INSPECT SILT FENCE WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. REMOVE SEDIMENT DEPOSITS TO REDUCE PRESSURE ON THE FENCE. ANY DAMAGED FABRIC SHALL BE REPAIRED OR REPLACED IMMEDIATELY AS REQUIRED. ,SILT CHECK FENCE CONFORMS TO EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL DETAIL 6.62 STAKES -\ -STRAW WATTLE F�� AREA TO BE /\ i, ° PROTECTED SECTION EROSION CONTROL NOTES: 1. THE CONTRACTOR SHALL TAKE WHATEVER MEASURES NECESSARY TO MINIMIZE SOIL EROSION AND SILTATION. HE SHALL KEEP FULLY INFORMED OF ALL SUCH REGULATIONS WHICH AFFECT THE CONDUCT OF THE WORK, AND SHALL AT ALL TIMES OBSERVE AND COMPLY WITH ALL SUCH REGULATIONS. 2. PERMANENT GROUND COVER SHALL BE ESTABLISHED ON ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES, AND ALL SLOPES GREATER THAN 3:1 WITHIN SEVEN (7) WORKING DAYS OF THE LAST LAND DISTURBING ACTIVITY. ALL OTHER DISTURBED AREAS SHALL BE PROVIDED WITH PERMANENT GROUND COVER WITHIN FOURTEEN (14) CALENDAR DAYS. GROUND COVER WILL CONSIST OF SEEDING, MULCHING AND FERTILIZING AS SPECIFIED. THE CONTRACTOR WILL BE REQUIRED TO FOLLOW THE LAND DISTURBING ACTIVITIES (AS CLOSELY AS PRACTICAL) WITH RESTORATION, FERTILIZING, SEEDING, AND MULCHING. 3. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSPECTED WEEKLY AND FOLLOWING EVERY RAIN EVENT. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. THE CONTRACTOR, UPON COMPLETION OF THIS PROJECT, SHALL LEAVE INTACT THOSE TEMPORARY EROSION CONTROL DEVICES DEEMED NECESSARY BY THE ENGINEER FOR FUTURE PROTECTION. 4. SEDIMENT FENCES (SILT CHECK FENCE) SHALL BE CONSTRUCTED WHERE SHOWN ON THE PLANS. CONSTRUCTION SHALL CONFORM TO EROSION CONTROL DETAIL 6.62. INSPECT SILT FENCES WEEKLY AND AFTER EACH RAINFALL. REMOVE SEDIMENT AS NEEDED TO MAINTAIN ADEQUATE STORAGE. IF SILT FENCE BECOMES DAMAGED OR COLLAPSES, REPLACE IMMEDIATELY. SILT FENCE SHALL BE REMOVED AFTER DRAINAGE AREA HAS BEEN STABILIZED. 5. ALL DISTURBED AREAS SHALL BE SEEDED WITH PERMANENT SEED FOR PRIMARY STABILIZATION AND TEMPORARY SEED FOR IMMEDIATE GROUND STABILIZATION. PERMANENT SEED SHALL BE KENTUCKY 31 FESCUE APPLIED AT A RATE OF 100LBS/ACRE. IF SEEDING WILL OCCUR BETWEEN AUGUST 15 AND APRIL 15, TEMPORARY SEED SHALL BE RYE GRAIN APPLIED AT A RATE OF 40 LBS PER ACRE. IF SEEDING WILL OCCUR BETWEEN APRIL 15 AND AUGUST 15, TEMPORARY SEED SHALL BE GERMAN MILLET APPLIED AT A RATE OF 10 LBS PER ACRE. 6. LIME AND FERTILIZER SHALL BE APPLIED WITH ALL SEEDING ACTIVITIES. A 5-10-10 GRADE OF FERTILIZER SHALL BE SPREAD AT A RATE OF 40LBS/1000SF. LIME SHALL BE APPLIED AT A RATE OF 75 LBS/1000 SF. 7. MULCH SHALL BE SPREAD UNIFORMLY AT A RATE OF 4,000 LBS/ACRE IN A CONTINUOUS BLANKET OVER THE AREAS SPECIFIED. THICKNESS OF THE COVERING SHALL BE ADEQUATE TO HOLD THE SOIL BUT SUFFICIENTLY LOOSE AND OPEN TO FAVOR THE DEVELOPMENT OF GRASS. 8. CONTRACTOR SHALL MAINTAIN A RAIN GAUGE AT THE PROJECT SITE AND PROVIDE WEEKLY AND POST RAINFALL INSPECTION REPORTS IN ACCORDANCE WITH NPDES REQUIREMENTS. EROSION CONTROL CONSTRUCTION SEQUENCE: 1. INSTALL EROSION CONTROL MEASURES IN ADVANCE OF LAND DISTURBING ACTIVITIES. 2. CONSTRUCT FACILITIES. 3. MAINTENANCE OF EROSION CONTROL DEVICES IS THE CONTRACTOR'S RESPONSIBILITY. EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAIN EVENT. THE DEVICES SHALL BE INSPECTED FOR DAMAGE AND REPAIRS SHALL BE COMPLETED IMMEDIATELY. 4. RESEED, MULCH, AND STABILIZE DISTURBED AREAS AS SOON AS PRACTICAL FOLLOWING UTILITY INSTALLATION. 5. MAINTAIN ALL EROSION CONTROL MEASURES. AFTER PROJECT AREA IS STABILIZED, REMOVE EROSION CONTROL DEVICES. EOc `ko r hl' PLAN NOTES: 1. WATTLES SHALL BE SECURED TO GROUND EVERY 2'-0" BY WOOD STAKES. 2. ALL DISTURBED DITCHES SHALL BE STABILIZED WITH EXCELSIOR MATTING. 3. INSPECT DITCHES WITH STRAW WATTLES WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. REMOVE SEDIMENT ACCUMULATED BEHIND THE WATTLES AND RESECURE STAKES, AS NEEDED. STRAW WATTLE L c c Lf 12'-0" MIN. o0p°O ��a 50 2-3" WASHED STONE 6" THICK (MIN.) o-6 C9. OO°C9.° 00 00000 Oot 0 0 0o O�0 w 0 0 z U) X NOTE: u' INSPECT TEMPORARY CONSTRUCTION ENTRANCE PERIODICALLY FOR CONDITION OF SURFACE. TOP DRESS WITH NEW WASHED STONE AS NEEDED. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS TRACKED ONTO PUBLIC ROADWAYS. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE CONFORMS TO EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL DETAIL 6.06 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F O Z U_ J U Z I N 00 N Q z J 0 ry U _ ry O Z W r 0 J ry Q U w U g U) w Y_ U) 0 0 0 U Z U) ry W W z cD Z w U) J ►a 0 I 00 I u7 0 I 0 I 0 I �N CARS Q�oFEss SEAL 22992 —DocuSigned by: ra�0-&6� -- 4576ADA7F49D43D... 6/27/2018 1:27:40 PM EDT 12" WALI SLEEVE q 672.0 SLIDE GATE MOUNTING BRACKETS EMBEDDED e IN CONCRETE (TYP) s_1 P LAN TYP) ALL WALLS #5 @ 6" CTS (EACH DIRECTION) (EACH FACE) ND (TYP) r v Z' n" 1—n» Z' n" 1—n» 1'—(1" #5 ® 6" CTS (EACH DIRECTION) (TOP AND BOTTOM) NOTE: 1. ALL VERTICAL BARS IN WALLS SHALL EXTEND FULLY INTO BOTTOM SLAB. ri -"� SECTION s-1 ' THICK DNCRETE PAD Yxs TGs ENGINEERS IN CHARGE CAWjrDUTCHMAN'S CREEK WWTP RENOVATION 1984.015 ENGINEERS 804—C N. LAFAYETTE STREET 2' 0 2' 4' FINALDRAWING TOWN OF MOCKSVILLE —SHELBY, NORTH CAROLINA 28150 DESIGNED RDE SECTION s-1.DWG PHONE 704.476.0003 MADE AMAFOR REVIEW PURPOSES ONLY IVIS ENGINEERS S-1 NC LICENSE NO. C-0275 CHECKED GJw NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES HEADWORKS PLAN A D JUNE 2018 0 0 0 0 0 o e o 0 0 0 0 0 o e 0 0 0 0 0 0 o e 0 0 0 O 0 0 0 o e 0 0 0 0 0 0 o e 0 #5 ® 6" CTS°° 0 e e e e e (EACH DIRECTION) ° ° e 0 ° ° ' (TOP AND BOTTOM) 0 0 ° 0 0 e e 0 0 e 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 o 0 o e 0 #5 ® 6" CTS ° ° ° (EACH DIRECTION) o o e (TOP AND BOTTOM) e e e e e e e e e° 10 0 0 0 e 0 o e o x'\x 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ° ° ° 0 0 0 ° ° ° 0 0 0 0 0 ' #5 ® 6" CTS\_6 VERTICAL BARS (TYP) C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o e e e e e e e e e o 0 0 0 0 #5 ® 6" CTS (EACH DIRECTION) (TOP AND BOTTOM) NOTE: 1. ALL VERTICAL BARS IN WALLS SHALL EXTEND FULLY INTO BOTTOM SLAB. ri -"� SECTION s-1 ' THICK DNCRETE PAD Yxs TGs ENGINEERS IN CHARGE CAWjrDUTCHMAN'S CREEK WWTP RENOVATION 1984.015 ENGINEERS 804—C N. LAFAYETTE STREET 2' 0 2' 4' FINALDRAWING TOWN OF MOCKSVILLE —SHELBY, NORTH CAROLINA 28150 DESIGNED RDE SECTION s-1.DWG PHONE 704.476.0003 MADE AMAFOR REVIEW PURPOSES ONLY IVIS ENGINEERS S-1 NC LICENSE NO. C-0275 CHECKED GJw NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES HEADWORKS PLAN A D JUNE 2018 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F L� c L L. c L I r r c" a a L c a a c.. z a c L LL c a a z c.: LL cr a a V LL V c c r c L L V a LL LL L L L LL ►J ■ 6/27/2018 1:27:40 PM EDT m 0 I 9" BEND (TYP) #5 © 6" CTS (T #5 1 VI\ LV 1 II L- SPLITTER BOX PLAN 12' -8' CTS (TYP) 4 SECTION s-2 6" CTS (TYP) TGS ENGINEERS IN CHARGE CAWjr 4' o' 4' 8' IGS DUTCHMAN'S CREEK WWTP RENOVATION 1984.015 EN01NEER5 804-C N. LAFAYETTE STREET DESIGNED RDE HNAL DRAWING _ TOWN OF MOCKSVILLE -SHELBY, NORTH CAROLINA 28150 'II' ® ENGINEERS S-2.DWG PHONE 704.476.0003 MADE BY AMA 2' 0' 2' 4' FOR REVIEW PURPOSES 0 N LY S-2 NC LICENSE NO. C-0275 NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES CLARIFIER P LAN & SPLITTER B 0 X CHECKED GJ W JUNE 2018 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F O z U_ J U z I N 00 N Q z_ J O ry Q U ry O z Li r O J ry Q U W U g U) w Y_ U) O O r - O U z U) ry W W z cD z w U) J -a ALLOWANCE FOR GROUT LAYER - 2'-0" 6 a COORDINATE BOX—OUT AND PIPE WITH APPROVED SHOP DRAWINGS rte' I 0c 22992 —DocuSigned by: 0 Kau V. &w ' 6/27/2018 1:27:40 PM EDT 4'—rips #5 DOWEL (TYP) 3'-0" #5 BARS © 12" CTS 1'-3" BEND 3" C 2" CLR 16' -0" 18'-0" 3 SECTION s-2 #5 @ 12" CTS (EACH DIRECTION) WATERSTOP (TYP) ,r#5 RADIALS (TYP) #5 BARS ® 12" CTS (ALONG PERIMETER) MAX #5 © 12" CTS (EACH DIRECTION) ri_*� SECTION s-2 0 I 5 BARS ® 12" CTS #5 LOOPS (TYP) 2" CLR 3'-0" SPLICE , R=15-0" 3" CLR #5 @ 12" (RADIAL) (TOP AND BOTTOM) SEE TYP. REINFORCING AT OPENING DETAIL THIS SHEET 0 > I WALL SLEEVE FOR 20" PIPE 2 SECTION s-2 3" BAR SPACING (TYP) it ---"--1/2 INTERRUPTED BARS (EACH SIDE OPENING, EACH DIRECTION) / (SAME LENGTH AS INTERRUPTED BAR) 15" FOR #4 20" FOR #5 24" FOR #6 TYP. REINFORCING AT OPENING 1'-6" SEE TYP. REINFORCING AT OPENING DETAIL THIS SHEE WALL SLEEVE FOR 20" PIF #5 ® 6" CTS PERIMETER E) DIRECTION EA '-0" BEND (TYP) PLAN AT OUTLET BOX IGS TGs ENGINEERS IN CHARGE CAWjr 0' 1984.015 ENGINEERS 804—C N. LAFAYETTE STREET 2' 24FINALDRAWING TOWN OF MOCKSVILLE ' —SHELBY, NORTH CAROLINA 28150 DESIGNED RDE IVIS ENGINEERS PHONE 704.476.0003 FOR REVIEW PURPOSES ONLY s-3.DWG S-3 NC LICENSE NO. C-0275 MADE ED AMA WASTEWATER FACILITIES CLARIFIER SECTIONS CHECKED GJw NOT RELEASED FOR CONSTRUCTION JUNE 2018 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F O Z U_ J U Z I N 00 N Q z J O ry U _ ry O Z Li 0 J ry Q U W U g n 67 W Y_ U) O O O U Z U) ry W W z cD Z w U) J ►a 0 I 00 •••••��N•CARD''•••, Q FESS IANC j�SI SEAL �7q9� • DocuSigned by: �� �l • ft.Llb� • �., 4576ADA7F49D43D... Da E1 ':•' •��.��met' 0 6/27/2018 1:27:40 PM EDT 18'-0" P LAN 5 @ 6" CTS .ACH DIRECTION) 'OP AND BOTTOM) of 0) #5 ® 6" CTS (EACH DIRECTION) (TOP AND BOTTOM) 2'-0" BEND (TYP)-\ 9" BEND (TYP)-� n O W cV U J a_ N 0 0 0 0 0 0 0 0 �9" BEND (TYP) �#5 @ 6" CTS (TYP) (EACH DIRECTION) 18'-0" (TOP AND BOTTOM) ri-"� SECTION s-4 IGS TGs ENGINEERS IN CHARGE CAWjr 0 1984.015 ENGINEERS 804—C N. LAFAYETTE STREET 2' 24FINALDRAWING TOWN OF MOCKSVILLE ' —SHELBY, NORTH CAROLINA 28150 DESIGNED RDE IVIS ENGINEERS PHONE 704.476.0003 MADE BY AMA FOR REVIEW PURPOSES ONLY S LU DG E P U M P I N G s-4.DWG S-4 NC LICENSE NO. C-0275 NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES CHECKED GJ W P LA N A N D SECTIONS JUN E 2018 O O O O O O O O O O O O O O OO O O O O O O O O O O O O O O O O O O O O O O O O ® O O O O O O O O O O O O O 0 . c4 a '. 0 0 w O U a- O a 0 0 O O J o a O o CV a- N o 0 0 0 0 0 0 o O o 0 0 0 0 0 o a 0 ° O 0 0 a0 0 0 0 0 0 a0 0 0 0 0 0 O O 0 0 0 a ® ° #5 © 6" CTS (TYP) 0 0 ° #4 @ 6" CTS (TYP) 00 (EACH DIRECTION) ° ° o (EACH DIRECTION) (EACH FACE) O 0 (EACH FACE) o O o Oa O 0 ®a ®° O 0 ®a O O O 0 ®a O O O 0 0 O ®° o 0 0 O O O o 0 ® ®® o ° ®a ®° O 0 0 0 0 O 0 ® 0 o ° 0 0 0 0 0 O O 0 0 ® O o ° 0 O O O 0 ® ®® o ° ® a cc 12" WALL CASTING O 0 0 o 0, O o O O o o O 0 2'-3„ o ° ° o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 n O W cV U J a_ N 0 0 0 0 0 0 0 0 �9" BEND (TYP) �#5 @ 6" CTS (TYP) (EACH DIRECTION) 18'-0" (TOP AND BOTTOM) ri-"� SECTION s-4 IGS TGs ENGINEERS IN CHARGE CAWjr 0 1984.015 ENGINEERS 804—C N. LAFAYETTE STREET 2' 24FINALDRAWING TOWN OF MOCKSVILLE ' —SHELBY, NORTH CAROLINA 28150 DESIGNED RDE IVIS ENGINEERS PHONE 704.476.0003 MADE BY AMA FOR REVIEW PURPOSES ONLY S LU DG E P U M P I N G s-4.DWG S-4 NC LICENSE NO. C-0275 NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES CHECKED GJ W P LA N A N D SECTIONS JUN E 2018 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F 0 I LO m"A j, 679.45 1 SECTION s-5 (RADIAL) ,,•••'N'cARo''••.,, SECTION s-5 •• O�� FESS Ip C �q'•• SEAL = 22992 DIGESTER PLAN � DaeuSigned by: 4576ADA7F49D43D... it Z 6/27/2018 1:27:40 PM EDT Y UJ -Li :DYTGS ENGINEERS IN CHARGE CAWjr 2' 0 2' 4' z ENGINEERS 804-C N. LAFAYETTE STREET FINALDRAWING E TOWN OF MOCKSVILLE DUTCHMAN'S CREEK WWTP RENOVATION 1984.015 � -SHELBY, NORTH CAROLINA 28150 DESIGNED RDE IVIS ENGINEERS S-S.DWG �n rf4 PHONE 704.476.0003 4' 0 4' 8' FOR REVIEW PURPOSES ONLY S-5 NC LICENSE NO. C-0275 MADE BY AMA NOT RELEASED FOR CONSTRUCTION WASTEWATER FACILITIES DIGESTER P A AND SECTIONS CHECKED GJ W JUNE 2018 DocuSign Envelope ID: D6A7DDB9-OB10-43D8-9EF2-01CC2125781F O z U_ J U Z I N 00 N Q z J ry Q U _ ry O Z W r 0 ry Q U Lj U g n cn W Y_ cn 0 0 r- 0 U Z cn ry W W z cD Z W cn J J -a GENERAL CONCRETE NOTES: 1. CONCRETE PROTECTION FOR REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED ON THE DRAWINGS: A. CONCRETE DEPOSITED DIRECTLY AGAINST SOIL - 3" B. CONCRETE EXPOSED TO WEATHER (#5 OR SMALLER) - 1 1/2" CONCRETE EXPOSED TO WEATHER (#6 OR LARGER) - 2" C. SLABS AT SURFACES CONTACTING WATER OR SEWAGE - 2" D. BEAMS AND COLUMNS (TO MAIN REINFORCEMENT) - 2" BEAMS AND COLUMNS (TO COLUMN TIES OR STIRRUPS) - 1 1/2" E. WALLS 12" OR MORE - 2" WALLS LESS THAN 12" (#5 OR SMALLER) - 1 1/2" WALLS LESS THAN 12" (#6 OR LARGER) - 2" F. FOR SURFACES EXPOSED TO WATER OR SEWAGE IN BEAMS, COLUMNS AND WALLS ADD 1/2" TO ABOVE. 2. SPLICES SHALL BE CLASS "B" CONFORMING TO THE PROVISIONS OF ACI 318 UNLESS NOTED OTHERWISE. 3. ALL EMBEDDED ITEMS SHALL BE INSTALLED AND SECURED IN PLACE BEFORE CONCRETE PLACEMENT. CONSULT ELECTRICAL, MECHANICAL AND HVAC DRAWINGS FOR PIPING, EMBEDDED ITEMS AND OPENINGS. 4. ALL JOINTS IN WATER BEARING STRUCTURES SHALL HAVE A WATERSTOP. ALL JOINTS BELOW GRADE IN WALLS OR SLABS WHICH ENCLOSE AN ACCESSIBLE AREA SHALL HAVE WATERSTOPS. 5. CONSTRUCTION JOINTS NOT SHOWN SHALL BE SUBMITTED BY THE CONTRACTOR FOR THE APPROVAL OF THE ENGINEER PRIOR TO SUBMITTING REBAR SHOP DRAWINGS. 6. PROVIDE VERTICAL CONSTRUCTION JOINTS IN WALLS AND HORIZONTAL JOINTS IN SLABS NOT GREATER THAN 45'-0" ON CENTER. 7. NO BACKFILL SHALL BE PLACED AGAINST ANY SUBSTRUCTURE WALLS UNLESS ADJACENT FLOOR SLABS HAVE TAKEN THEIR FINAL SET, OR WALLS HAVE BEEN PROPERLY BRACED, AND IN ANY CASE NOT SOONER THAN 28 DAYS AFTER THE PLACING OF CONCRETE UNLESS APPROVED BY THE ENGINEER. 8. LOAD FACTOR DESIGN METHOD. 9. NO VEHICULAR LOADING TO STRUCTURES. 10. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI. 11. CONCRETE SHALL BE AIR ENTRAINED. 12. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. 13. REQUIRED FOUNDATION BEARING CAPACITY OF 2,000 PSF. 14. FOUNDATION SHALL BE TESTED BY A GEOTECHNICAL ENGINEER TO ASSURE REQUIRED BEARING CAPACITY HAS BEEN ACHIEVED. 15. ALL EXPOSED EDGES SHALL BE CHAMFERED 3/4". Q�FESS 1p,�,l SEAL 22992 Docu�Siigned byy:+. J� a • I-�4576ADA7F49D43D... 6/27/2018 1:27:40 PM EDT BASIC DEVELOPMENT LENGTH AND SPLICE LENGTH DEVELOPMENT LENGTH AND SPLICE FOR BARS IN COMPRESSION fy = 60,000 psi fc' = 3000 psi OR FOR BARS IN TENSION LENGTH BAR SIZE fy = 60,000 psi fc' = 3000 psi OR GREATER LENGTH, I dh CONFINEMENT 9" SPLICE LENGTH *** DEVELOPMENT LENGTH *** 12" 12" W, #3 Id g" #4 BAR 1.3 x Id 12" CLASS B #5 11" 1'-2" SIZE 1'-7" V-3" 1'-5" #7 1'-1" 1'-8" #6 1'-11" 1'-6" 1'-8" #9 **TOP *OTHER #7 2'-3" *OTHER **TOP *OTHER BASIC *OTHER 2'-7" BAR TOP BAR SIDE COVER NORMAL TO PLANE OF HOOK 1'-11" 2'-1 to BAR TOP BAR #9 20-1000 2'-2" 2'-4" #3 1'-5" 1'-11" 1'-7" 1'-5" 1'-5" 2'-6„ 1'-11" 1'-7" 2'-0" #4 1'-11" 2'-6" 2'-0" 1'-9" 1'-9" NOT LESS THAN 1/4 INCH DIAMETER AND NOT #4 TIES IN CONFORMANCE WITH ACI 318, INCHES ON CENTER, FACTOR 0.75 USED. 2'-4" 1'-11" #5 2'-4" 3'-1" 2'-6" 2'-1" 2'-1" 2'-9" 2'-3" #6 2'-9" 3'-7" 2'-11" 2'-5" 2'-5" 3'-2" 2'-7" #7 3'-2" 4'-2" 3'-4" 2'-11" 2'-9" 3'-10" 3'-1" #8 3'-10" 5'-0" 4'-0" 3'-8" 3'-1" 4'-10" 3'-11" #9 4'-10" 6'-4" 5'-1" 4'-8" 3'-9" 6'-1" 4'-11" #10 6'-1" 7'-11" 6'-4" 5'-9" 4'-8" 7'-6" 6'-0" #11 7'-6" 9'-9" 7'-10" * BARS WITH CLEAR SPACING NOT LESS THAN 5 TIMES THE BAR DIAMETER AND CLEAR COVER FROM FACE OF MEMBER AT LEAST 2.5 TIMES THE BAR DIAMETER, FACTOR 0.8 USED. ** TOP REINFORCEMENT IS HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT, FACTOR 1.3 USED. *** LENGTHS SHOWN IN CHART SHALL BE MODIFIED WHERE REQUIRED TO CONFORM TO THE PROVISIONS OF ACI 318, SECTION 12.2.3. 1-1/2" MIN. BEARING I I I� REINFORCE a CONCRETE a G 'd GRATING OR DECKING AS SPECIFIED CONTINUOUS ANGLE W/ 1/2" X 3" HD STUDS ® 24" OC. GRATING DETAIL BASIC DEVELOPMENT LENGTH AND SPLICE FOR BARS IN COMPRESSION fy = 60,000 psi fc' = 3000 psi OR LENGTH GREATER BASIC DEVELOPMENT LENGTH BAR SIZE SPLICE LENGTH BASIC CONFINEMENT * BASIC LENGTH, I dh CONFINEMENT 9" 8" #3 12" 12" W, #3 91, g" #4 1'-3" 12" 1'-2" #5 11" 1'-2" #5 1'-7" V-3" 1'-5" #7 1'-1" 1'-8" #6 1'-11" 1'-6" 1'-8" #9 1'-3" 2'-1" #7 2'-3" 1'-9" 1'-10" #11 1'-5" 2'-7" #8 2'-6" SIDE COVER NORMAL TO PLANE OF HOOK 1'-11" 2'-1 to 1'-7" #9 20-1000 2'-2" 2'-4" 1'-9" Idh #10 3'-3" 2'-6„ 2'-7" 2'-0" #11 3'-7" 2'-9" * BARS ENCLOSED WITHIN SPIRALS WITH MORE THAN 4 INCH PITCH OR WITHIN SECTION 7.10.5 AT NOT MORE THAN 4 NOT LESS THAN 1/4 INCH DIAMETER AND NOT #4 TIES IN CONFORMANCE WITH ACI 318, INCHES ON CENTER, FACTOR 0.75 USED. EXTERIOR FA CHAMF WHERE EXPOS RUBBER OR P\ TYPE WATERST( ASIDE OF ;TRUCTURE ;EALER 1/2's LL REINFORCING CONTRACTION JOINT OR CONSTRUCTION JOINT EXTERIOR F CHAM WHEF EXPO 1 " JOINT FILI RUBBER BULE TYPE WATERS - DEVELOPMENT LENGTH OF STANDARD HOOKS FOR BARS IN TENSION fy = 60,000 psi fc' = 3000 psi OR GREATER BAR DEVELOPMENT LENGTH, I dh SIZE BASIC W/ CONC. COVER #3 g" 7„ #4 11 " 8" #5 1'-2" 10" #6 l'-5" 12" #7 1'-8" 1'-2" #8 1'-10" 1'-4" #9 2'-1" 1'-6" #10 2'-4" 1'-8" #11 2'-7" * SIDE COVER NORMAL TO PLANE OF HOOK AT LEAST 2 1/2"; AND FOR 90' HOOK END COVER BEYOND OUTSIDE END OF HOOK AT LEAST 2'. E::: I :n Idh Idh ASIDE OF >TRUCTURE >EALER 1 /2" STEEL THRU JOINT EXPANSION JOINT TGS TGS ENGINEERS IN CHARGE CAWjr 1' 0' 1' 2' 1984.015 ENGINEERS 804-C N. LAFAYETTE STREET FINALDRAWING TOWN OF MOCKSVILLE DUTCHMAN'S CREEK WWTP RENOVATION -SHELBY, NORTH CAROLINA 28150 DESIGNED RDE IVIS ENGINEERS NC LICENSE N0. C-0275 PHONE 704.476.0003 FOR REVIEW PURPOSES ONLY s-6.DWG S-6 MADE BY AMA 0.5 0 0.5 1 WASTEWATER FACILITIES DETAILS CHECKED GJw NOT RELEASED FOR CONSTRUCTION JUNE 2018 ►i 00 N Q Z_ J ry U ry O z Li r_ O 1 ry Q U w U n cn Lu Y O O r - O U z cn ry Lu Lu z c� z Lu J J Q TO PARSHALL FLUME NO. 2 NEW 6" THICK CONCRETE PAD ROAD BOX (TYP.)� O O 12" MJ PLUG VALVE (TYP.) -<" STAIRS HANDRAIL MOUNTEDFRAME-MOUNTED M� z DUMPSTER M52 TO WALL OF STRUCTURE CONTROL PANEL PROVIDED BY OTHERS 14'- 0" Ee 3'-0" WIDE STAIRS 11 TREADS @ 11" 12 RISES @ 7.5"- 4'X3'-6" PLATFORM. GRATING NOT SHOWN FOR CLARITY.— 27 JUNE 2018 SEAL •�= 17710 ,RT H��,.��`'� RATING (TYP.) Io 0 0 0 o 0 0 0 0 0 100 00 00 DRAIL (TYP.) eI 6" FLOOR DRAIN (BELOW) M-2 SCREEN WASHER AND CONVEYOR 0 c b 4 M-2 MULTI -RAKE SCREEN IIVJV LFII LU ABOVE GROUND ENCLOSURE WITH 1" RPZ BACKFLOW PREVENTER PH 12" DIP (TYP.) TO PARSHALL- ----- __ FLUME NO. 1 -- 00 I in 12" FORCE MAIN 4 FROM INFLUENT M-2 n PUMP STATION - - - --i II YARD HYDRANT \Q/ WASHWATER FOR SCREENING WASHER. VERIFY SIZE WITH EQUIPMENT MANUFACTURER. EXPOSED WATER LINE SHALL BE HEAT TRACED AND INSULATED. --- 41K-�� TO EXISTING DRAIN EXISTING 10" DIP-\ 1-1 � II 1-4 12" X 10" MJ 90• REDUCING BEND w w — 2" WATER CONCRETE HEADWORKS STRUCTURE. SEE SHEET S-1. w 4'-0" I e n M-2 w I >T>>>Q L ------ w \IA-IrEr'D 1" TO PARSHALL FLUME NO. 3 �6" DRAIN I FROM 6" FLOOR DRAIN ABOVE w Lo I� YARD HYDRANT PLAN AT EL. 671.50 TO HYDRANTINSUTED WITHLA1 " R ZBOVE BACKFLOWN PREVENTOER ENCLRE O z (.3_ J U Z I N 00 N Q z J ry U ry O Li O 1 ry Q U Li U I U) w Y V) O O O U z ry w w z cD z w U) J J Q 27 JUNE 2018 �cgRO''% FF SS%ptil �— :Q l^ SEAL •�= 17710 o. A• ,RTH11,1111110 ��,.��`', MULTI -RAKE BAR SCREEN MANUAL BAR SCREEN (BEYOND) 3'-0" , ,2'-0» SEE WEIR PLATE DETAIL THIS SHEET SEE NOTE 3 12" MJ 90° BEND 1 SECTION M-1 ONTROL PANEL FRAME OF WELDED 4" SQUARE ALUMINUM TUBE GRATING SUPPORT (TYP.) SEE SHEET S-6. STAINLESS STEEL ANCHORS IN CONCRETE STRUCTURE 6" THICK CONCRETE PAD 1/4" THICK ALUMINUM WEIR PLATE WITH 2" X 1-1/8" SLOTTED OPENING WITH 1" DIA. S.S. BOLTS AND WASHERS 6� - N -id WEIR PLATE DETAIL MULTI -RAKE BAR SCREEN 675.00 673.00 RATING (TYP.) m 3' 3-8" I 666.25 I HANDRAIL SUPPORT. SEE SHEET S-6. SEE WEIR PLATE DETAIL THIS SHEET - - �12" DIP (TYP) *SEE NOTE 4 MULTI -RAKE BAR SCREEN r2__'� S ECT 0 NM -1 6" THICK CONCRETE PAD NOTES: SCREW SCREEN CONVEYOR 1. ALL GRATING AND HANDRAILS SHALL BE SUPPORTED AS SHOWN ONDISCHARGE HANDRAIL (TYP.) SHEET S-6. 4'-Osp 4'-OX 39-69' / CHUTE STAIR PLATFORM MANUAL SCREEN. 2. TOP OF MANUAL BAR SCREEN AND SLIDE GATE GUIDES SHALL NOT SHOWN FOR INTERFERE WITH GRATING SYSTEM. MANUAL BAR SCREEN IS SHOWN REFERENCE. AT A 45 DEGREE ANGLE OF INSTALLATION. SEE NOTE 2. 675.00 _ 675.00 SCREENINGS 3. CONTRACTOR TO MATCH DEPTH OF NEW 12" HEADWORKS EFFLUENT 00 WASHER AND PIPING WITH EXISTING 10" EFFLUENT PIPING. ' CONVEYOR DUMPSTER ss 4. CONTRACTOR TO VERIFY DEPTH OF EXISTING 8" DRAIN AND PROVIDE 672.00 (BY OTHERS)- , UNIFORM SLOPE OF NEW DRAIN. 671.00 rr CONCRETE PEDESTAL TO MOUNT I I 5. HARD PIPE OF SCREENINGS WASHER AND CONVEYOR TO CHANNEL. OVERFLOW 3' SCREENINGS WASHER AND CONVEYOR CONTRACTOR TO PROVIDE SLEEVE IN WALL. VERIFY SIZE OF DRAIN 668.75 SLIDE GATE AND LOCATION WITH EQUIPMENT MANUFACTURER.41 - II �6" THICK CONCRETE PEDESTAL TO 6" THICK �- CONCRETE PAD MOUNT SCREENINGS CONCRETE PAD 664.42 - WASHER AND CONVEYOR 6" FLOOR DRAIN SEE_ NOTE 4 DRAIN. SEE NOTE 5. �6" DRAIN 4 SECTION M-1 r5_'� SECTION M-1 0 :: N 00 N Q z J ry U ry O w O 1 ry Q U w U g n cn Lu Y_ O O O U z cn ry Lu Lu z cD z Lu J J Q HANDRAIL (TYP. 110'-0" SLUDGE PUMPING DETAILED ON SHEET M-5 0 2 I I M-4 O O CLARIFIER NO. 1 � I SLUDGE RAKE AND SKIMMER 12" 22.5° MJ BEND (TYP.) A� i / 12" CLARIFIER DRAIN TO SANITARY SEWER II NEW SIDEWALK (TYP.)— 0 o� �4" PRV (TYP.) CLARIFIER NO. 2 M44 I M44 I =_4 ------------------ \ I �8" SCUM (TYP.) SCUM BOX j 0 12" SLUDGE / / / 0 \ LINE (TYP.) II I //// 26• / / 3 WIDE ACCESS / BRIDGE WITH 1 HANDRAIL (TYP.) 0 1 I I gM-_4�M.3 \ / �/ 12„ DRAIN 1 1 I II II II i' I (TYP.) OUTLET BOX (TYP.) SEE SHEET M-4 12" PLUG YARD / II It 20' MJ /' / II I I VALVE (TYP.) �,P. HYDRANT 4—�20 MJ 22.5' I I I I 90•BEND I / / I (TYP.) I I BEND (TYP.) ------------------------- — -- --- --- --- — -- —---------------- ----------------.�---- ---------� ------------- ------------�---------_.i. i 27 JUNE 2018 �cgRO''% LVS1 % pal :Q l^o SEAL •�= 17710 o. ,lFs .,FYG I mF �\\�\.; A• ,RTH11,1111110 ��,.��`'� 1 II fir; �1 w w /ILII II w w w w w w w 2" WATER 4" WAS FORCE MAIN TO I I I I L I f THICKENER / DIGESTER GRATING SUPPORT 20" INFLUENT FROM 1 1 //'/' I GRATING (TYP)l (TYP.) SEE SHEET S- SPLITTER BOX (TYP.) 1 1 9 1 I M -s 1 II I � 2 M SPLITTER BOX. GRATING NOT SHOWN FOR CLARITY. II— II W M-3 20" INFLUENT FROM AERATION BASINS *665.00 - *662.50 - +660.50 *659.00 - 20" INFLUENT FROM AERATION BASINS PROVIDE LINK SEAL ON INSIDE FACE 1/4" THICK ALUMINUM WEIR PLATE WITH 2" X 1-1/8" SLOTTED OPENING WITH 1" DIA. S.S. BOLTS AND WASHERS "7\SII � 20 INFLUENT TO CLARIFIER NO. 2 ri_"� SECTION M-3 WEIR PLATE (TYP.)- *661.75 NOTES: 1. ALL PIPING SHALL BE DIP UNLESS OTHERWISE NOTED. 2. PROVIDE ONE SLIDE GATE CONSTRUCTED OF 1/4" THICK ALUMINUM PLATE. TOP OF SLIDE GATE SHALL EXTEND TO 6" BELOW TOP OF GRATING. PROVIDE HANDLE FOR SLIDE GATE. 3'-0" BRACKET FOR SLIDE GATE EMBEDDED IN CONCRETE (TYP.) 1 _ ____j 1 SEE NOTE 2. ru-1 rT II. .If �M�% 656.00 11 ,�1,�I 20" INFLUENT TO CLARIFIER (TYP) 2 SECTION M-3 O U_ J U z I N 00 N Q z J ry Q U ry O z Li r O 1 ry Q U W U g n U) Lu Y_ V) O O r - O U z ry w w z CD z Lu U) J J Q A lel r-tl f" f'1f11 f\nr %IIITI 1 11 A A111 fl A II 27 JUNE 2018 �� �CqRO''% ;F F SS % ptil :Q l° SEAL •�= 17710 ,RT H��,.,�`', 663.50_ GROUT VARIES 8" TO 2" AT OUTLET OL 647.25 I V UI/11VIC I CR IJCIV I CR D/1JC 1 SECTION M-3 HANDRAIL 3/4" CHAMFER rWEIR PLATE. SEE 71 DETAIL THIS SHEET. +�3» ' EL STATIC L.L. 661.50 2'-0" — `SCUM BAFFLE 1'-4" 60' DIAMETER GROUT VARIES 3" TO 0" AT CENTER BASE 2 SECTION M-4 +644.25 NOTES: 1. 12" SLUDGE LINE (NOT SHOWN) TO HAVE CENTERLINE ELEVATION OF 644.25. 2. CONTRACTOR TO CONFIRM REQUIRED ANGLES WITHIN CENTER BASE PRIOR TO CONSTRUCTION. WALL SLEE% WITH LINK ' WALL SI WITH LII 20" EFFLUENT PLAN AT OUTLET BOX 3 K'-3 SECTION M-3 M-4 _LE 50 STATIC L.L. 661.50 WEIR PLATE 90° ® II 1 N 0 "-,3" X 1 1/8" SLOTTED '-0" O.C. OPENING WITH 1 " DIA. S.S. BOLTS AND WASHERS CLARIFIER WEIR DETAIL SCUM BAFFLE WEIR EXTEND SCUM BAFFLE 4'16" BELOW LIQUID LEVEL AND 4' ON EACH SIDE OF SCUM BOX WALL SLEEVE WITH LINK SE 4 S ECTI 0 NM -3 3/4" CHAMFER 8" SCUM DRAIN O z U_ J U Z I N 00 N Q Z_ J O ry Q U ry O Z W r O J ry Q U W U g n U) Lu Y_ U) O O r - O U z ry w w z c� z Lu U) J J Q 27 JUNE 2018 CARO''% %04, :Q l^o SEAL •�= 17710 A• ,RTH1111111110 ��,.,�`', ELECTRICAL EQUIPMENT PAD VALVE VAULT 31-61$X4'-6" LE LEAF 3S DOOR 4'-0" 6" THICK CONCRETE PAD WITH 6X6/10:10 WWF 2'-10" X 3'-10" PRECAST VALVE VAULT WITH 2'X3'-6" SINGLE LEAF ACCESS DOOR— ELECTRICAL EQUIPMENT PAD PROVIDE ANGLE IRON FOR GRATING SUPPORT BETWEEN PRECAST WALL AND W SECTION - 2' -10" X 3'-10" PRECAST VALVE VAULT WITH 2'X3'-6" SINGLE LEAF ACCESS DOOR - 00 2'X2' N ACCE --- --77 VALVE onv ASPHALT DRIVE W8X28 HAND RAI L 3 M-7 GRATING 4'X4' PRECAST WET WELL O LJ PROVIDE 2" BLOCK OUT FOR W8X28 3'X3' PRECAST _ - VALVE VAULT WITH 2'X2' SINGLE LEAF ACCESS DOOR 10'-0"X11'-6" WET WELL WITH 5" WIDE DIVIDER WALL 6'X6' PRECAST VALVE VAULT WITH 31-61JX4'-6" DOUBLE LEAF ACCESS DOOR NOTES: 1. ALL ACCESS DOORS SHALL BE EQUIPPED WITH FALL PROTECTION. :: N 00 N Q z J ry U ry O w U g n V) W Y_ U) O O r - O U Z cn ry Lu Lu z c� z Lu J J Q 27 JUNE 2018 LV *.o , SEAL •�= W- 17710 o. ,lFs .,FYG I mF o** A• ,RTH1111111110 ��,.��`'� CLARIFIER NO. 1 N 8" SCUM DRAIN (TYP.) 19 \ �12" SLUDGE LINE (TYP.) ELECTRICAL I EQUIPMENT PAD SHOWN FOR REFERENCE. i L 7 12" CLARIFIER DRAIN ELECTRICAL EQUIPMENT PAD SHOWN FOR REFERENCE. r CLARIFIER NO. 2 II (o II 0) II s M2� SEE NOTE 3. 5 M-7 6 M-7 II II _— -- ---- O II ' 4 ' II > )1 1 6 - 0 ao 1 , 4 r' II IlO 00 ' II II 21 24 15 _ II � II 6 00' I1 SEE NOTE 3. 27'-p» M -s I I SEE NOTE 3.11o (D ————— — — — — —— ®-------- ------ ' I I /' 20 INFLUENT 11111 loll II II � II II 14 r --1r II II II II II II 4 M-7 mN 5o O� Zn Wm D K: N Z Z NN ' II 21 / / -------------- /�--------------- II / 6J BELOW GRADE K: cy) D Z� D O 1-1N N C7 N � --A -T1 m0 X;a Nn m PIPING SCHEDULE 01 4" RAS PUMP O2 4" FLG 90° ELBOW O3 4" FLG/PE DIP ® 4" FLG CHECK VALVE O5 4" FLG PLG VALVE © 4" FLG TEE O7 4" MJ 90° ELBOW ® 4" DIP O9 4" MJ TEE 10 4" PE/FLG DIP 11 4" FLOW METER 12 4" X 6" FLG ENLARGER 13 6" FLG PLUG VALVE 14 6" FLG/PE DIP 15 3" WAS PUMP 16 SCUM PUMP 17 3" X 4" FLG ENLARGER 18 4" RUBBER COUPLING 19 8" PE DIP 20 12" MJ 22.5° ELBOW 21 12" PE 12" DIP 22 12" MJ PLUG VALVE 23 12" WALL CASTING 24 12" FLG PLUG VALVE 25 24" PE DIP NOTES: 1. ALL PIPE PENETRATIONS IN PRECAST STRUCTURES SHALL HAVE LINK SEALS ON INSIDE WALL. 2. CONTRACTOR MAY UTILIZE COMPANION FLANGES AS NEEDED. 3. PROVIDE 1/4" NTP TAP WITH ISOLATION VALVE FOR FUTURE PRESSURE GAUGE (TYP. OF 3). O Z U_ J U z I N 00 N Q z J ry U ry O z Li r_ O 1 ry Q U Li U g n U) Lu Y_ U) O O r - O U z ry w w z cD z Lu U) J J Q 663.50 10"X1 V1 -61p WET WELL WITH 8" WIDE DIVIDER WALL - 644.25 Ir 642.50 641.00 C Ir 6'X6' PRECAST VALVE VAULT WITH 3'-6" X 4'-6" DOUBLE LEAF ACCESS DOOR 4" 90° ELBOW 3'-6"X4'-6" DOUBLE LEAF ACCESS DOOR - 4" 90° ELBOW 810 3'-6"X4'-6" DOUBLE LEAF ACCESS DOOR (TYP.) +663.00 6 4" FLG. DIP 4" RAS PUMP 4" DISCHARGE ELBOW. SEE NOTE 1. 1 1 S ECTI 0 NM -5 M-6 CONCRETE PAD (TYP 658.67 I II 67 27 JUNE 2018 CARO''% 104**, :Q l^ SEAL •2")= 17710 ,RT H�,.��`', 6'X6' PRECAST VALVE VAULT WITH 2'-6"X5' DOUBLE LEAF ACCESS DOOR - a• 4" FLOW -4" FLG. METER TEE ONCRETE BALLAST (TYP.) 4"X6" ENLARGE 4" FLG. PLUG VALVE 12" SLUDGE LINE (SHOWN OUT OF POSITION). 3'-6"X4'-6" DOUBLE LEAF ACCESS DOOR - 12" THICK WALL (TYP. 12" PLUG VALVE WITH EXTENDED STEM (SHOWN OUT OF POSITION) ,644.00 642.50 641.00 VALVE BOX (SHOWN OUT OF POSITION) 4" 90° ELBOW 3" WAS P U M 2'X2' SINGLE LEAF ACCESS DOOR 4" CHECK VALVE 4" PLUG VALVE 301X411 FLG ENLARGER 3" FLG DIP 2'-10"X3'-10" PRECAST VALVE VAULT WITH 2'X3'-6" SINGLE LEAF ACCESS DOOR 3" DISCHARGE ELBOW rT� 2 S ECTI 0 NM -5 M-6 663.00 6 658.67 8-1/2" 8' X 18' FOOTING 2'-10"X3'-10" 3'X3' PRECAST PRECAST VALVE VAULT VALVE VAULT WITH -VALVE WITH 2'X3'-6" SINGLE 2'X2' SINGLE LEAF BOX ASPHALT LEAF ACCESS DOOR ACCESS DOOR 50 663.00 663.00 659.75 0 0 _ _ 659.83 658 67 4" 90° 4" FLG. 4" FLOW 6" PLUG VALVE ELBOW TEE METER ADJUSTABLE PIPE SUPPORT (TYP.) r4'� 4 SECTION M-5 J-6 r5_'*'� 5 SECTION M-5 J-6 3" X 4" FLG ENLARGE HANDRAIL STAINLESS STEEL 6 63.50 ANGLE IRON WITH STAINLESS STEEL ANCHOR BOLTS (TYP.) W8 X 28-// OL 656.00 Ir 651.50 4'X4' PRECAST WET WELL WITH BASE EXTENTION- 4" FLG RUBBER COUPLING �4" FLG CHECK VALVE (m m f4" FLG 90° BEND 4" FLG PLUG VALVE II 0659.83 4" MJ 90° BEND " SCUM DRAIN FROM CLARIFIER (TYP.) SCUM PUMP 3 rT� S ECTI 0 NM -5 M-6 NOTES: 1. IF RAS PUMP IS 3" PUMP, PROVIDE 3" DISCHARGE ELBOW WITH 3" X 4" FLG ENLARGER. 2. PROVIDE LINK SEALS ON STRUCTURE INTERIOR FOR ALL WALL PENETRATIONS. 3. CONTRACTOR SHALL CONFIRM EXISTING RAS / WAS PIPING ELEVATION PRIOR TO CONNECTING NEW PIPING. 4. ALL ACCESS DOORS SHALL BE EQUIPPED WITH FALL PROTECTION. 5. PROVIDE SS LIFTING CHAIN FOR RAS AND WAS PUMPS. O z U_ J U z I N 00 N Q Z_ J O ry Q U ry O Z W r O J ry Q U W U g n cn Lu Y_ O O r - O U z cn ry Lu Lu z c� z Lu J J Q 27 JUNE 2018 CARO''% 104' Q l° : SEAL •�= 17710 o. %les - YG I mF o** A• ,RTH11,1111110 ��,.��`'� VALVE BOX (TYP) PIPING SCHEDULE O O1 6" FLG DIP O 6" FLG 90• BEND O O3 6" FLG 45• BEND EXISTING WAS DISCHARGE PIPING EXISTING E 6" THICK CONCRETE F WITH 6X6/10:10 WWF 24' X 30' PRECAST f'%l 111 x lkl^ NOTES: 1. ALL NEW POLYMER FEED SYSTEM PIPING TO BE SCHEDULE 80 PVC. COORDINATE PIPE AND FITTING SIZES WITH APPROVED EQUIPMENT. EACH CONNECTION TO THE NEW FEEDER TO BE PROVIDED WITH AN ISOLATION BALL VALVE AND UNION. ALL PIPING TO BE MOUNTED TO THE WALLS WITH STAINLESS STEEL BRACKETS. NEW DIGESTER :: ry O z w 0 1 ry Q U W U n U) W Y_ U) O O r - O U z cn ry Lu Lu z c� z Lu J J Q 27 JUNE 2018 �cgRO''% F F SS % ptil :Q l^o SEAL •�= 17710 o. A• ,RTH11,1111110 ��,.��`', PIPING SCHEDULE 0 6" MJ TEE 0 6" MJ PLUG VALVE O 6" PE DIP ® 6" MJ 90• BEND ® 8" MJ 90• BEND © 8" MJ DIP 07 8" MJ 45• BEND ® 8" MJ TEE 0 8" MJ 22.5• BEND 0 I N N 0 1 f'9 II II 18'-0" ' 1 a 22 12' (TYP.) 4-4 w II II II II II II II w II �2" WATER LINE II II II II II � II a Di 2'-0» a 0,0 EXISTING DIGESTER (TYP.) ====of YARD HYDRANT (TYP.) w w 52'-0" 0 0 I I I I I I I I I I I I I I I i© I I I I I I I I I I I I I I I I I I I I I I I I 24' X 30' PRECAST BUILDING. SHOWN FOR REFERENCE. col 4:: - - - - - - - - - -a-0 II II II II II c II 1 I ' --LL----------------7------- --r1---------------- � -- I I / / I/ I 07 I I I II I II II I II I II I II I II I II I II I II I 9 10 - w 77 w — 24'-0" _ APPROX. 10' (9��— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I 0 ❑O Q i i Q Q - - - - - - - - - - - - - - - - - - - - - -- - _ �IFif`-'-�-'I�------------------ --------------- F -------------- -------- - ----- - - - - - - - - - - - - - - - - - - - NOTES: 1. ITEMS SHOWN IN BOLD ARE NEW. 2. CONTRACTOR SHALL COORDINATE LOCATION OF FLOOR PENETRATIONS FOR THICKENER SYSTEM WITH APPROVED SHOP DRAWINGS. /-b O U_ J U Z I N 00 N Q z J O ry Q U _ ry O Z W r O ry Q U W U g n U) Lu Y_ U) O O r - O U z ry w w z 0 z Lu U) J J Q 6" THICK CONCRETE SIDEWALK WITH 6X6/10:10 WWF 27 JUNE 2018 CARO''% :Q l° SEAL •�= 17710 ,RT H�,.��`', YE POLYMER FEED LINE POLYMER SLUDGE MIXING TANK [THICKENER , r 8" FLG - 6" FLG - PE PIPE ---'PE PIPE * 665.00 " MJ 90° BEND 664.00 8" MJ 90° BEND THICKENER DISCHARGE CHUTE TO SLUDGE PUMP. DISCHARGE PIPE SHOWN OUT OF POSITION. "W�6" FLG - PE PIPE * 665.00 6" MJ 90° BEND 1 1 SECTION M-8 M-9 DOORWAY SHOWN FOR REFERENCE. - - POLYMER FEED LINE. SEE NOTE 2. POLYMER FEEDER - 12" CONCRETE SLAB WITH #5@12" EW T&B 2 2 S ECT 0 NM -8 M-9 PRECAST BUILDING NOTES: 1. ALL SLUDGE AND DRAIN PIPING SHALL BE DIP UNLESS OTHERWISE NOTED. 2. POLYMER FEED LINE SHOULD BE PLACED ALONG CEILING. PROVIDE PIPE SUPPORTS AS NEEDED. ROLL UP ,1K, SLUDGE THICKENING ISOMETRIC O z U_ J U Z I N 00 N Q Z_ J O ry Q U ry O Z W r- 0 J ry Q U W U g n U) Lu Y_ U) O O r - O U z ry w w z CD z Lu U) J J Q 27 JUNE 2018 CARO''% 104' Q l^ : SEAL •�= 17710 A• ,RTH1111111110 ��,.��`', AERATION BASIN NO. 3 d d dO d a a 4a d a a 25' O a Lo a O 1d a SLUDGE a THICKENING `NEW BLOWER SLAB. BUILDING SEE SHEET M-14. NOTES: 1. ALL ITEMS SHOWN IN BOLD ARE NEW. 2. CONTRACTOR SHALL PROVIDE NEW PLATFORM. DESIGN CALCULATIONS AND DRAWINGS FOR A COMPLETE SYSTEM, INCLUDING BUT NOT LIMITED TO THE PLATFORM, COLUMNS, GRADING, AND FOOTINGS, SHALL BE SUBMITTED FOR APPROVAL AS SHOP DRAWINGS. CALCULATIONS AND DRAWINGS SHALL BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA. :: N 00 N Q z J ry U ry O z Li r O 1 ry Q U Li U g n U) Lu Y_ U) O O r - O U z cn ry Lu Lu z c� z Lu J J Q FVLIT FIT F 8" MJ TEE ROTATED AS NEEDED SLUDGE DRAIN TO INFLUENT PUMP STATION 27 JUNE 2018 �cgRO''% p�c ESS % pal :Q l^o SEALo •�= °: 17710 ,lFs .,Fo. YG I mF o** A• ,RT H�,.��`'� i� N 8" MJ 90° BEND ROTATED AS NEEDED II II II I I II II II I I II ABANDONED 6" DECANT PIPING I I I I II 8" MJ COUPLING I II � 0 � II T II II SEE SHEET 10'-0" I I G-7 FOR CONNECTION II II DETAIL II II II II z O Q N n D a_ w c� 0 D N O rK LL 8" MJ 22.5• BEN NEW SLUDGE II II //i 8" MJ 45° BEND 1 1 8" AIR I I PIPING / II 11 //i II //- 8" - g II // II 8" MJ I I I I I I 8" X 6" MJ II II II REDUCER II II 6" AIR PIPING I 1 6" MJ TEE W W MIN. - - - - - - - - - - -------- l.., 1 II Ful II 0 II II ' NP' NEW PLATFORM COLUMN AND FOOTING (NP) �I ro XISTING II PLATFORM II II II / 8" MJ nn• nrKin 8" DECANT DRAIN A8" SLUDGE DRAIN CONCRETE PAD AT STAIR LANDING (TYP.) EW BLOWER LAB. SEE HEET M-14. NOTES: ALL ITEMS SHOWN IN BOLD ARE NEW. O z U_ J U z I N 00 N Q z J O ry Q U ry O z Li r O 1 ry Q U W U g n U) Lu Y_ U) O O r - O U z ry w w z c� z Lu U) J J Q 27 JUNE 2018 �cgRO''% FF SS%ptil �— :Q l^ SEAL •�= 17710 o. A• ,RTH1111111110 ��,.��`', U`. 1 1 SECTIONM-1 1 t-13) LADDER DETAIL vu�iu� U/'lJL DIGESTER NO. 2 SECTION AT AIR HEADER (DIGESTER N0. 1 SIMILAR) NOTES: 1. ALL ITEMS SHOWN IN BOLD ARE NEW. 2. SECTION VIEWS MAY CONTAIN ITEMS SHOWN OUT OF POSITION FOR CLARITY. 3. BOTTOM OF NEW PLATFORM SHALL BE AT LEAST 6" ABOVE THE TOP OF THE WALL. 4. THE NEW DIGESTER TOW ELEV. SHALL MATCH THE EXISTING TOW ELEV. OF THE EXISTING DIGESTER. 5. CENTER OF NEW AIR PIPING SHALL EXTEND 42" OVER THE TOW. 6. THE NEW SLUDGE DRAIN AND DECANT PIPING SHALL MATCH THE ELEVATION OF THE EXISTING SLUDGE DRAIN ON THE EXISTING AEROBIC DIGESTER. AS DISCHARGE. SHOWN - POSITION. SEE NOTE 13. 7. CONTRACTOR SHALL PROVIDE PIPE SUPPORTS AS NEEDED. 8. CONTRACTOR SHALL DEFLECT WAS AND AIR PIPING AS NEEDED TO AVOID CONFLICT WITH FOOTER OF STRUCTURES. 9. ALL PIPE SHALL BE DIP UNLESS OTHERWISE NOTED. 10. PVC PIPING SHALL BE SCH 80 PVC. SHED GRADE 11. PROVIDE ADJUSTABLE PIPE SUPPORTS WITH U -BOLT CLAMPS ON 6" AIR HEADER AND 3" AIR LATERALS, SPACED MAX. 5' ON CENTER. 12. COORDINATE WITH TELESCOPING VALVE MANUFACTURER TO ENSURE ADEQUATE SUPPORT AND BRACING FOR FLOOR STAND AND VALVE. 13. EXPOSED WAS DISCHARGE PIPING (NEW AND EXISTING) SHALL BE HEAT TRACED AND INSULATED. PIPING SCHEDULE TELESCOPING VALVE LADDER SECURED TO PLATFORM AS RECOMMENDED BY MANUFACTURER 1 0 6" MJ 90° BEND WITH FLOOR STAND (TYP.) SEE NOTE 12. PROVIDE SAFETY GATE O2 6" PE-FLG DIP AT HANDRAIL OPENING 6' WIDE PLATFORM WITH O 6" FLG 90° BEND 1-1/2" ALUMINUM HANDRAIL 4„ ® 6" FLG BUTTERFLY VALVE 0 6" FLG DIP 6" © 6" FLG 45° BEND MAX. L.L. MAX. L.L. ELEV. 677.45 - - ELEV. 677.45 O7 6" FLG-PE PVC 18 SUPPORT COLUMN SHOW 1811'8 FOR REFERENCE (TYP) O 6" PVC 90° BEND DIGESTER NO. 1 O 12 12 O DIGESTER NO. 2 O9 6" PVC PIPE MIN. L.L.MIN. LADDER L.L. 10 8" DIP ELEV. 672.45 - - ELEV. 672.45 FINISHED GRADE DIGESTER 11 8" MJ 90° BEND 13 13 12 8" TELESCOPING VALVE 13 8" FLG DIP CORE HOLE 8» AND PROVIDE 14 O 8" FLG-PE DIP LINKSEAL (TYP)-\ r.,ie�Ti►in ernrnin ninrrTrn U`. 1 1 SECTIONM-1 1 t-13) LADDER DETAIL vu�iu� U/'lJL DIGESTER NO. 2 SECTION AT AIR HEADER (DIGESTER N0. 1 SIMILAR) NOTES: 1. ALL ITEMS SHOWN IN BOLD ARE NEW. 2. SECTION VIEWS MAY CONTAIN ITEMS SHOWN OUT OF POSITION FOR CLARITY. 3. BOTTOM OF NEW PLATFORM SHALL BE AT LEAST 6" ABOVE THE TOP OF THE WALL. 4. THE NEW DIGESTER TOW ELEV. SHALL MATCH THE EXISTING TOW ELEV. OF THE EXISTING DIGESTER. 5. CENTER OF NEW AIR PIPING SHALL EXTEND 42" OVER THE TOW. 6. THE NEW SLUDGE DRAIN AND DECANT PIPING SHALL MATCH THE ELEVATION OF THE EXISTING SLUDGE DRAIN ON THE EXISTING AEROBIC DIGESTER. AS DISCHARGE. SHOWN - POSITION. SEE NOTE 13. 7. CONTRACTOR SHALL PROVIDE PIPE SUPPORTS AS NEEDED. 8. CONTRACTOR SHALL DEFLECT WAS AND AIR PIPING AS NEEDED TO AVOID CONFLICT WITH FOOTER OF STRUCTURES. 9. ALL PIPE SHALL BE DIP UNLESS OTHERWISE NOTED. 10. PVC PIPING SHALL BE SCH 80 PVC. SHED GRADE 11. PROVIDE ADJUSTABLE PIPE SUPPORTS WITH U -BOLT CLAMPS ON 6" AIR HEADER AND 3" AIR LATERALS, SPACED MAX. 5' ON CENTER. 12. COORDINATE WITH TELESCOPING VALVE MANUFACTURER TO ENSURE ADEQUATE SUPPORT AND BRACING FOR FLOOR STAND AND VALVE. 13. EXPOSED WAS DISCHARGE PIPING (NEW AND EXISTING) SHALL BE HEAT TRACED AND INSULATED. .: ry O z w r- 0 ry Q U W U g n U) w Y_ U) O O r - O U z cn ry Lu Lu z c� z Lu J J Q 6" THICK CONCF SIDEWALK WITH 6X6/10:10 WWF 27 JUNE 2018 CARO''% ESS % pal :Q l^ SEAL •�= °: 17710 TH��,.��`'� b � TO AEROBIC PLAN DIGESTERS 1 & 2 1 S ECTI 0 N t -2,4) LEGEND: O1 RELIEF VALVE WITH PRESSURE GAUGE O2 6" WAFER STYLE CHECK VALVE O3 6" WAFER STYLE BUTTERFLY VALVE ® 6" x 8" FLG. ENLARGER O5 8' 90° BEND © 8" FLG TEE O 8" FLG PIPE ® 8" MJ 90° BEND ONCRETE PAD O9 8" PE DIP )R BLOWERS 8" FLG-PE 10 8" MJ 45° BEND DISCHARGE CAST IN PLACE-\ CONCRETE SLAB CONCRETE PAD. VERIFY DIMENSIONS V BLOWER MANUFACTUR 2 SECTION M BLOWER mini ncci for FRAME CONCRETE PAD DETAIL EW 12" THICK ONCRETE SLAB WITH 5 @ 12" EW/TAB JCRETE PAD AND EXPDXY ANCHOR BOLTS INTO EXISTING CONCRETE PAD. EMBED MIN. 4". ANCHOR BOLT SIZE SHALL BE PER MANUFACTURER'S RECOMMENDATION (MIN. 5/8" SS). NOTES: 1. CONTRACTOR TO DETERMINE BLOWER DISCHARGE PIPING AND PAD ELEVATION BASED ON APPROVED BLOWER EQUIPMENT. 2. CONTRACTOR SHALL PROVIDE PIPE SUPPORTS AS NEEDED. 3. CONTRACTOR TO DETERMINE EXACT SLAB SIZE FROM SPATIAL INFORMATION PROVIDED. CONTRACTOR SHALL SUBMIT DIMENSIONAL DRAWING OF LAYOUT WITH BLOWER SHOP DRAWING SUBMITTAL. O 71 U_ J U Z N 00 N Q Z_ J O ry Q U H- D' O Lj r O J ry Q U Lv U g n U) Lv Y_ U7 O O r - O U Z cn O' Lu Lu Z cD Z Lu J J Q 27 JUNE 2018 CARO''% SEAL 9504 EXISTII OVERH OLD CHLORINE BUILDING TO BE REMOVED I — — — — — — — — — — — — — — — — — — —— I CHLORINE I SLUDGE DRYING BED TO BE REMOVED I L ---------- I IB 15 — — — — — — — — — — IN 2 F_ EXISTING \ CHLORINE L_ BUILDING REMOVE TO REMAIN i O REMOVE ACK-MOUNTED EXISTING ELECTRICAL SLUDGE PUMP PANEL _ CABINETS BUILDING 2 CLB2 0 i TO REMAIN CLARIFIER 1 PANEL EXISTING REMBE OVED TO BE\� SPB3 �� CLARIFIER 2 \ 10 1 BE ROEMOVED O o' ©---- --- ----�-----�-- -- -�-b---------- ----- --------------- II II 18 II I I I I I I I �I 171 �I -025 HP iii 025 HP I 1 li 1 I I AERATION BASIN 1 I AERATION BASIN 2 II I I I I I I I �I I O O— �I � I � I --025 HP -----025 HP 1 EXISTING IN—GROUND ® 1 BOXES TO REMAIN El ®O I I Ili � i❑ ❑ �I �O o U z ? II ND II m J W m I EXISTING LAB BUILDING 0 EXISTING SITE PLAN - ELECTRICAL 1"=30' CHLOINE CONT CT BASIN RS BLOWER EACH i i 5 HP CH I® 12 I i I 13 I II � I I � I I � I � I EXISTING PANEL O ii SPB3 SLUDGE PUMP BUILDING 3. O TO REMAIN II / CLARIFIER 3 \\ MCC3ING TO BE ii REMOVED I � II � II � 0 II d 5 omBE -�a� � � 025 HP AERATION BASIN 3 25 HP I ❑ �o 0❑ EXISTING AEROBIC DIGESTER ------------------- EXISTING CONTROL PANEL REMOVE EXISTING FEEDER TO BE R�MOVED OVERHEAD FEEDERS EXISTING CELL 1 FEEDER OVERHEAD. 3 #4/0 + 0❑ EXISTING AEROBIC DIGESTER ------------------- EXISTING CONTROL PANEL REMOVE EXISTING FEEDER TO BE R�MOVED OVERHEAD FEEDERS EXISTING CELL 1 FEEDER OVERHEAD. 3 #4/0 + #1 NEUT + #1 GND. ALL XHHW CU. O2 EXISTING CELL 2 FEEDER OVERHEAD. 3 350 KCMIL + #1 NEUT + #1 GND. ALL XHHW CU. O3 EXISTING CELL 3 FEEDER OVERHEAD. 3 350 KCMIL + #1 NEUT + #1 GND. ALL XHHW CU. GENERAL NOTES — ELECTRICAL DEMOLITION NOT ALL EXISTING ELECTRICAL WORK IS SHOWN ON THESE PLANS. EXISTING ELECTRICAL SYSTEMS SHALL BE PROTECTES AND MAINTAINED IN SERVICE UNLESS SPECIFICALLY INDICATED FOR REMOVAL. WHERE FEEDERS ARE TO BE REMOVED, ALL ABOVE -GROUND WORK SHALL BE ELIMINATED. UNDERGROUND CONDUIT MAY BE ABANDONED IN PLACE. EXISTING WOOD POLES AND OVERHEAD CONDUCTORS SHALL REMAIN IN PLACE UNLESS NOTED OTHERWISE. ROUTING OF EXISTING UNDERGROUND CONDUITS SHOWN ON THESE DRAWINGS IS APPROXIMATE AND NOT ALL-INCLUSIVE. CONTRACTOR SHALL LOCATE EXISTING UNDERGROUND WORK AND MAINTAIN IN SERVICE AS REQUIRED. DRAWING REFERENCE NOTES 0 EXISTING AERATOR CONTROL PANEL TO REMAIN. O2 OLD CHLORINE BUILDING TO BE REMOVED. REMOVE ELECTRICAL FEEDER, DISCONNECT SWITCH, AND CONNECTION TO OVERHEAD LINES. OLD CLARIFIER 1 AND RELATED EQUIPMENT TO BE REMOVED. REMOVE ASSOCIATED ELECTRICAL WORK, INCLUDING DISCONNECT AND CONNECTION TO OVERHEAD LINES. ® EXISTING SLUDGE PUMP BUILDING 2 TO REMAIN. BUILDING IS SERVED BY 100A SWITCH CONNECTED TO OVERHEAD LINES. 05 EXISTING SLUDGE PUMP BUILDING 3 TO REMAIN. BUILDING IS SERVED BY 200A SWITCH CONNECTED TO OVERHEAD LINES. © EXISTING 200A SWITCH, FUSED 150A, FEEDS CHLORINE BUILDING. MAINTAIN IN SERVICE. 0 EXISTING FUSED SWITCH NOW SERVING AEROBIC DIGESTER. 200A 3P 240V NEMA 4X. 150A FUSES. REMOVE EXISTING FEEDER TO AEROBIC DIGESTER. LEAVE SWITCH IN PLACE. ® EXISTING SYSTEM OF IN -GROUND PULL BOXES AND CONDUITS CONTAINS MISCELLANEOUS POWER CIRCUITS. PROTECT FROM DAMAGE DURING CONSTRUCTION AND MAINTAIN IN SERVICE AS REQUIRED. 0 EXISTING SYSTEM OF IN -GROUND PULL BOXES AND CONDUITS CONTAINS CONTROL AND COMMUNICATIONS WIRING. PROTECT FROM DAMAGE DURING CONSTRUCTION AND MAINTAIN IN SERVICE AS REQUIRED. 10 EXISTING IN -GROUND STRUCTURE WITH SLUDGE PUMPS FOR CLARIFIER 1 TO BE REMOVED. REMOVE ELECTRICAL FEEDER, DISCONNECT, AND CONNECTION TO OVERHEAD LINES. 11 EXISTING POLE -MOUNTED AREA LIGHTING FIXTURES TO REMAIN. 12 EXISTING BLOWERS TO REMAIN. TWO ® 5 HP. FED FROM PANEL CLB3 AT CHLORINE BUILDING. 13 EXISTING BLOWERS TO REMAIN. TWO ® 5 HP. FED FROM MCC3. HANDHOLE 0 STAINLESS STEEL ANCHOR BOLTS #6 BARE CU FROM GROUNDING LUG TO DRIVEN ELECTRODE OF COPPER—CLAD STEEL #3 BARS TIED ALL AROUND 12" ON CENTER 20" DIAMETER 0 I N to I 1 CONCRETE BASE TO EXTEND 18" ABOVE FINISHED GRADE. ALL SURFACES FINISHED SMOOTH. CHAMFER CORNERS. GRADE #6 BARS TIED TO ANCHOER BOLTS POST LIGHT TYPE P2 SCALE: 3/8" = 1'-0" 27 JUNE 2018 `,,,111111►,,,,, :Q l: SEAL 9504 '��►►1111111111` BASE OF 3000psi REINFORCED CONCRETE BOLT COVERS LED FLOODLIGHTS. CAST ALUMINUM CAST => HOUSING. ADJUSTABLE KNUCKLE BASEPLATE MOUNT. MINIMUM 11,000 LUMEN XHHW CU. OUTPUT. 120V. PHOTOCELL CONTROL. EXISTING CELL 2 FEEDER GRAY OR ALUMINUM FINISH. ESH-C2 HUBBELL FLL-42L-95-5K—M + #, GND. ALL XHHW CU. OR EQUAL BY ATLAS OR LITHONIA. BULLHORN FIXTURE 30 EXISTING BRACKET OVERHEAD. 3 350 KCMIL + 1" = 30' TENON MOUNTED. + #1 GND. ALL XHHW CU. NON—TAPERED ROUND ALUMINUM POLE. CHLORINE MINIMUM 4" DIAMETER AND .250" WALL THICKNESS. GRAY PAINT FINISH, CONTACT RATED FOR SUSTAINED 10OMPH ,,'' _",;j ,, WIND WITH GUST FACTOR OF 1.3 WITH BASIN 2 BASIN FIXTURES FURNISHED. HUBBELL RSA—S SERIES OR EQUAL. HANDHOLE 0 STAINLESS STEEL ANCHOR BOLTS #6 BARE CU FROM GROUNDING LUG TO DRIVEN ELECTRODE OF COPPER—CLAD STEEL #3 BARS TIED ALL AROUND 12" ON CENTER 20" DIAMETER 0 I N to I 1 CONCRETE BASE TO EXTEND 18" ABOVE FINISHED GRADE. ALL SURFACES FINISHED SMOOTH. CHAMFER CORNERS. GRADE #6 BARS TIED TO ANCHOER BOLTS POST LIGHT TYPE P2 SCALE: 3/8" = 1'-0" 27 JUNE 2018 `,,,111111►,,,,, :Q l: SEAL 9504 '��►►1111111111` BASE OF 3000psi REINFORCED CONCRETE STAINLESS STEEL BOLTS WITH LEVELING NUTS. #3 BARS TIED ALL AROUND 6" ON CENTER BOLT COVERS EXISTING CAST => ALUMINUM BASEPLATE STAINLESS STEEL BOLTS WITH LEVELING NUTS. #3 BARS TIED ALL AROUND 6" ON CENTER I ❑ / PC EL I I 2"C TO CABINET TCC IN -GROUNDS PULL BOXES III cE' I II 0' II © ------- FEEDER _ ___FEEDER TO III NEW PANEL II ili or, II I 25 HP III II 1 i II II II AERATION BASIN 1 I I II I I I I II i II II i II I I I I I I 25 HIP II ® 1 I I I I I I II II ❑ III I I III ' III_____________=-- VIII BE e GE II II I I I I I c� z i li z (n m J 57< m TRANSFORMER r�---------- GENERATOR -------- INFLUENT PUMPS 30 HP EACH 0 0 Fel JAI ` I EXISTING CHLORINE i BUILDING TO REMAIN' EXISTING PANEL SPB3 SLUDGE PUP EXISTING ° ` BUILDING 3 O i SLUDGE PUMP PANEL �'ll TO REMAIN� BUILDING 2 CLB2 o TO REMAIN i EXISTING EXISTING \ MCC3 i PANEL SPB2 I i 8 OII il0 i -- a — ',aE of o ----- -- -------------- ----- - --------------- i n 0 25 HP AERATION BASIN 3 25 HP ID NEW HEADWORKS SEE SHEET E-5 EQUIPMENT SHELTER NEW SLUDGE ESH-B THICKENING BUILDING j E:1:1r7 n, AERATION -J L -J Li- BLOWERS PANEL Pn DI ST 1 0 OVERHEAD FEEDERS u EQUIPMENT EXISTING CELL 1 FEEDER OVERHEAD. 3 #4/0 + I #1 NEUT SHELTER XHHW CU. O2 EXISTING CELL 2 FEEDER OVERHEAD. 3 350 KCMIL + ESH-C2 #, NEUT + #, GND. ALL XHHW CU. NEW SITE PLAN - ELECTRICAL 30 EXISTING CELL 3 FEEDER OVERHEAD. 3 350 KCMIL + 1" = 30' #1 NEUT + #1 GND. ALL XHHW CU. CHLORINE CHLORINE CONTACT CONTACT ,,'' _",;j ,, }_,_ BASIN 2 BASIN EQUIPMENT ;' SHELTER BLOWERS It— BLOWERS � HP EACH'I 5 HP EA H IESH-C1 ,;%� 115 12 � 13 I ❑ / PC EL I I 2"C TO CABINET TCC IN -GROUNDS PULL BOXES III cE' I II 0' II © ------- FEEDER _ ___FEEDER TO III NEW PANEL II ili or, II I 25 HP III II 1 i II II II AERATION BASIN 1 I I II I I I I II i II II i II I I I I I I 25 HIP II ® 1 I I I I I I II II ❑ III I I III ' III_____________=-- VIII BE e GE II II I I I I I c� z i li z (n m J 57< m TRANSFORMER r�---------- GENERATOR -------- INFLUENT PUMPS 30 HP EACH 0 0 Fel JAI ` I EXISTING CHLORINE i BUILDING TO REMAIN' EXISTING PANEL SPB3 SLUDGE PUP EXISTING ° ` BUILDING 3 O i SLUDGE PUMP PANEL �'ll TO REMAIN� BUILDING 2 CLB2 o TO REMAIN i EXISTING EXISTING \ MCC3 i PANEL SPB2 I i 8 OII il0 i -- a — ',aE of o ----- -- -------------- ----- - --------------- i n 0 25 HP AERATION BASIN 3 25 HP ID NEW HEADWORKS SEE SHEET E-5 EQUIPMENT SHELTER NEW SLUDGE ESH-B THICKENING BUILDING j E:1:1r7 n, AERATION -J L -J Li- BLOWERS PANEL Pn DI ST 1 0 OVERHEAD FEEDERS u 0 EXISTING CELL 1 FEEDER OVERHEAD. 3 #4/0 + #1 NEUT + #1 GND. ALL XHHW CU. O2 EXISTING CELL 2 FEEDER OVERHEAD. 3 350 KCMIL + #, NEUT + #, GND. ALL XHHW CU. NEW SITE PLAN - ELECTRICAL 30 EXISTING CELL 3 FEEDER OVERHEAD. 3 350 KCMIL + 1" = 30' #1 NEUT + #1 GND. ALL XHHW CU. LED FLOODLIGHTS. CAST ALUMINUM HOUSING. ADJUSTABLE KNUCKLE MOUNT. MINIMUM 4600 LUMEN OUTPUT. 95 LPW. 120V. PHOTOCELL CONTROL. GRAY OR ALUMINUM FINISH. HUBBELL FML -20L -52 -5K -RM OR EQUAL BY ATLAS OR LITHONIA. 3ULLHORN FIXTURE 3RACKET TENON MOUNTED. NON-TAPERED ROUND ALUMINUM POLE. MINIMUM 3" DIAMETER AND .250" WALL THICKNESS. NATURAL ALUMINUM ANODIZED FINISH. RATED FOR SUSTAINED 10OMPH WIND WITH GUST FACTOR OF 1.3 WITH FIXTURES FURNISHED. o 00 J�J� BOLT COVERS CAST ALUMINUM HANDHOLE 1/2" STEEL PLATE BASEPLATE WELDED TO TOP OF PLATFORM STRUCTURE. STAINLESS STEEL BOLTS WITH LEVELING NUTS. POST LIGHT TYPE P1 SCALE: 3/8" = 1'-0" HEAVY DUTY COVER. SET 1" ABOVE FINISHED GRADE. "CONTR( COMMUNICATIONS AND CONTROL STAINLESS STEEL TAMPERPROOF HEAVY DUTY COVER BOLTS COVER. SET 1 " ABOVE FINISHED GRADE. LABEL "ELECTRICAL" ONE-PIECE OR TWO -SECTION (STACKED) BOX OF POLYMER CONCRETE, FIBERGLASS i� ? REINFORCED.`14 M 0 QUAZITE PG STYLE OR EQUAL ALL JOINTS SEALED WATERTIGHT ) SOLID BOTTOM 8" LAYER PEA STONE WITITIImks aI11]1110V IN -GROUND PULL BOXES NOT TO SCALE ►i LL r C Q 7 c.. LL c Q a U LL U c.: L U a LL LL L L L LL 27 JUNE 2018 \�\ 1 CARO''% 'S rQ l^ SEAL 9504 ON L. �- ",11111 LIGHTING FIXTURE SCHEDULE 0 4ft LONG ENCLOSED AND GASKETED INDUSTRIAL LED FIXTURE. FIBERGLASS -REINFORCED POLYESTSER HOUSING. 6000 LUMEN MINIMUM OUTPUT. MAXIMUM 65W. SUSPEND VIA CHAIN HANGERS. METLUX 4VT2 LD4-6-L840 „V LED WALL PACK FIXTURE. CAST ALUMINUM HOUSING. 4 BOROSILICATE GLASS REFRACTOR. MINIMUM 3200 LUMENS. LABEL FOR WET LOCATION. HUBBELL WGH-81L-5K-S OR APPROVED EQUAL. (MAXIMUM INPUT 32W) 1r EMERGENCY LIGHTING UNIT WITH BATTERY RESERVE. 12V LONG -LIFE LEAD BATTERY - MINIMUM CAPACITY 2 HRS O 24W. STEEL HOUSING. WALL MOUNT. EMERGI-LITE 121LSEE36 OR EQUAL. A PHOTOCELL CONTROL PD -1 VIA PHOTOCELL CONTROL J H10 G n.. CONNECT 7 u u WIRE BRKR CK SIZE AMPS NO. UNSWITCHED�� EXTERIOR LIGHTING LOAD SERVED 20 1 .4 A ® A ® A 20 3 10 SPARE .2 20 5 FEEDER TO r�_- ; (G) 20 7 PANEL PDrf rF I PD -3 PANEL 1.1 iPD yQ----a�--}--j r� 1 � (G) 20 11 1.1 Y ---`i3 (G) 20 13 w SPARE (G) 20 15 LIGHTING PLAN NEW SLUDGE THICKENING BUILDING SCALE: 1/8" = 1'-0" KVA LOAD LOAD SERVED KVA LOAD WIRE BRKR CK SIZE AMPS NO. .4 EXTERIOR LIGHTING LOAD SERVED 20 1 .4 LIGHTING .2 20 3 10 SPARE .2 20 5 .4 RECEPT (G) 20 7 .4 RECEPT (G) 20 9 1.1 POLYMER PUMP (G) 20 11 1.1 POLYMER PUMP (G) 20 13 8 SPARE (G) 20 15 8 SPARE (G) 20 17 8 RECEPT DIGESTER 2 .4 22 20 11.1 ROTARY DRUM THICKENER 8 40 21 24 20 SPARE (GE) ❑ 26 20 BREAKER SPARE (GE) /113 10.0 UNIT HEATER HEAT TRACE (GE) 8 40 27 30 20 6 RECEPT HEADWORKS .4 SPACE ONLY 6 TREATMENT CELL #3 34 60 SPACE ONLY HEADWORKS 9.0 SPACE ONLY CONTROL PANEL BREAKER LA FRAME SQUARE D TYPE NQ SURFACE MOUNTED - NEMA 1 120/208V 3 PHASE 4 WIRE 225A BUSSES AND NEUTRAL 150A MAIN BREAKER ® BOTTOM PANEL SHALL BE RATED 22,000AIC ABC (G) = GFCI CIRCUIT BREAKER (5mA) (GE)= GFPE CIRCUIT BREAKER (3OmA) PANEL PD ;KT BRKR WIRE 40. AMPS SIZE LOAD SERVED KVA LOAD 2 20 7 SPARE LOAD SERVED 4 20 10 BLOWER CONTROL PANEL .2 6 20 10 RECEPT BLOWER PAD .2 8 20 SPARE SO 10 20 BREAKER LA FRAME SPARE SO 12 20 SPACE ONLY SPARE 14 20 3 SPARE DIGESTER AREA 16 20 8 RECEPT DIGESTER 1 .4 18 20 8 HEAT TRACE (GE) 1.0 20 20 8 RECEPT DIGESTER 2 .4 22 20 8 HEAT TRACE (GE) 1.0 24 20 SPARE (GE) ❑ 26 20 BREAKER SPARE (GE) /113 28 20 6 HEAT TRACE (GE) 1.0 30 20 6 RECEPT HEADWORKS .4 6 TREATMENT CELL #3 34 60 41 HEADWORKS 9.0 CONTROL PANEL BREAKER LA FRAME LOAD TABULATION CATEGORY GROSS USE NET LIGHTING .8 @ 125 % = 1.0 MOTORS (NON -HVAC) 22.3 © 100 % = 22.3 HVAC 10.0 © 100 % = 10.0 MISCELLANEOUS 5.4 © 50% = 2.7 TOTALS 38.5 36.0 NEW FEEDER UNDERGROUND TO PANEL PC I 2"C TO CABINET TCC '11 FOR CONTROLS AND 1 COMMUNICATIONS ' 1 X11 I X11 Ix /x I/x 1 /x 1/x x UTILITY PRIMARY 1 OVERHEAD LINE I ,.-----------�---- -11 UTILITY I X00 PRIMARY CABLE UNDERGROUND EXISTING 1600A UNDERGROUND I FEEDERS EXISTING UNDERGROUND I FEEDER TO INFLUENT PUMP STATION I ♦�10,I 400 KW GENERATOR I UTILITY PADMOUNTED TRANSFORMER 300 KVA -EXISTING FEEDERS FROM MDP TO POLES VIA WEATHERHEADS II I I -- - - - - - - - - - - - - - - - - -J❑ ---- L - - - - - - - - - - - - - - � I II -IIIi - - - - - - - - - - - - - - - - - - -- I II II 2"C FOR III TO NEW SLUDGE CONTROLSTHICKENING BUILDING ELECTRICAL PLAN - LAB BUILDING AREA SCALE: 1/8" = 1'-0" EXISTING SWITCHBOARD MDP SQUARE D TYPE QED POWERSTYLE SWITCHBOARD, 1600A MAIN BUSSES. 1 r1 ALL CIRCUIT BREAKERS LISTED BELOW ARE EXISTING, UNLESS 7 UNIT LOAD SERVED 350A DEVICE DESCRIPTION SO 8 1 TREATMENT CELL #2 70.0 2 350A SO 9 BREAKER LA FRAME SO 2 SPACE ONLY SO 3 /1 10 DIGESTER AREA 101.5 SO 300A 60A 4 BREAKER LA FRAME r111 BREAKER 4 SO 76.0 200A /112 NEW 5 rl 400A ❑ BREAKER 200A /113 GE aBE MOLDED CASE CIRCUIT 400A 200A 6 l 1 400A /114 250A II I I -- - - - - - - - - - - - - - - - - -J❑ ---- L - - - - - - - - - - - - - - � I II -IIIi - - - - - - - - - - - - - - - - - - -- I II II 2"C FOR III TO NEW SLUDGE CONTROLSTHICKENING BUILDING ELECTRICAL PLAN - LAB BUILDING AREA SCALE: 1/8" = 1'-0" EXISTING SWITCHBOARD MDP SQUARE D TYPE QED POWERSTYLE SWITCHBOARD, 1600A MAIN BUSSES. 120/208V 3 PHASE 4 WIRE. ALL CIRCUIT BREAKERS LISTED BELOW ARE EXISTING, UNLESS NOTED OTHERWISE. UNIT LOAD SERVED KVA DEVICE DESCRIPTION RATING NOTES 1 TREATMENT CELL #2 70.0 MOLDED CASE CIRCUIT 350A BREAKER LA FRAME 2 SPACE ONLY - 3 DIGESTER AREA 101.5 MOLDED CASE CIRCUIT 300A NEW BREAKER LA FRAME BREAKER 4 CLARIFIER AREA 76.0 MOLDED CASE CIRCUIT 300A NEW BREAKER LA FRAME BREAKER 5 INFLUENT PUMP 93.0 MOLDED CASE CIRCUIT 400A STATION BREAKER LA FRAME 6 TREATMENT CELL #3 68.0 MOLDED CASE CIRCUIT 400A BREAKER LA FRAME 7 SPACE ONLY - 8 SPACE ONLY - 9 SPACE ONLY - 10 TVSS MOLDED CASE CIRCUIT 60A BREAKER 11 - MOLDED CASE CIRCUIT 200A BREAKER 12 - MOLDED CASE CIRCUIT 200A BREAKER 13 PANEL L1 5.0 MOLDED CASE CIRCUIT 200A BREAKER JG FRAME 14 TREATMENT CELL #1 54.0 MOLDED CASE CIRCUIT 250A BREAKER JG FRAME V V I O Z U_ 1 U Z I N 00 N Q z J O ry U D' O w O 1 ry Q U w U g 11 cn Lu Y_ Ln O O r - O U z D' Lu Lu z c� z w J J CONTROL PANELS SHALL BE PROVIDED BY AN APPROVED PANEL FABRICATOR AND SHALL BEAR UL LABEL. PANEL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL. DOORS SHALL BE CONTINUOUS HINGE TYPE WITH LOCKING LEVER HANDLES. CIRCUIT BREAKER OPERATING HANDLES AND OPERATOR INTERFACES SHALL BE ON DEAD -FRONT PANELS CONCEALED BEHIND THE OUTER DOORS. ALL CIRCUIT BREAKERS SHALL BE NEMA MOLDED CASE TYPE. PILOT LIGHTS TO BE LED PUSH -TO -TEST NEMA 4X. EACH CONTROL PANEL SHALL INCLUDE ALL WIRING, DEVICES, HARDWARE, AND COMPONENTS REQUIRED FOR A COMPLETE AND PROPERLY FUNCTIONING SYSTEM. CONTROL PANELS SHALL INCLUDE FEATURES AND COMPONENTS AS FOLLOWS: CP -R RECYCLE PUMPS MOLDED CASE ELECTRONIC MOTOR CIRCUIT PROTECTOR DISCONNECT FOR EACH OF FOUR 7'/2HP RECYCLE PUMPS. SQUARE D MPC OR EQUAL. NEMA TYPE MAGNETIC CONTACTOR FOR EACH PUMP. ELECTRONIC OVERLOAD RELAY. REMOTE RESET WITH CONTROL ON DEAD -FRONT PANEL. HOA SWITCH FOR EACH PUMP. "RUN" AND "FAULT" PILOT LIGHTS ON OUTER DOOR FOR EACH PUMP TOGGLE SWITCH DISCONNECT FOR 120V CONTROL POWER. CP -W WASTE PUMPS MOLDED CASE ELECTRONIC MOTOR CIRCUIT PROTECTOR DISCONNECT FOR EACH OF TWO 3HP WASTE PUMPS. SQUARE D MPC OR EQUAL. NEMA TYPE MAGNETIC CONTACTOR FOR EACH PUMP. ELECTRONIC OVERLOAD RELAY. REMOTE RESET WITH CONTROL ON DEAD -FRONT PANEL. HOA SWITCH FOR EACH PUMP. "RUN" AND "FAULT" PILOT LIGHTS ON OUTER DOOR FOR EACH PUMP TOGGLE SWITCH DISCONNECT FOR 120V CONTROL POWER. CP -S SLUDGE PUMPS MAIN DISCONNECT CIRCUIT BREAKER. 100A. MOLDED CASE ELECTRONIC MOTOR CIRCUIT PROTECTOR DISCONNECT FOR EACH OF TWO 10HP SLUDGE PUMPS. SQUARE D MPC OR EQUAL. NEMA TYPE MAGNETIC CONTACTOR FOR EACH PUMP. ELECTRONIC OVERLOAD RELAY. REMOTE RESET WITH CONTROL ON DEAD -FRONT PANEL. HOA SWITCH FOR EACH PUMP. "RUN" AND "FAULT" PILOT LIGHTS ON OUTER DOOR FOR EACH PUMP TOGGLE SWITCH DISCONNECT FOR 120V CONTROL POWER. CP -B BLOWERS MAIN DISCONNECT CIRCUIT BREAKER. 250A MOLDED CASE ELECTRONIC MOTOR CIRCUIT PROTECTOR DISCONNECT FOR EACH BLOWER. SQUARE D MPC OR EQUAL. SOFT -START CONTROLLER WITH ELECTRONIC OVERLOAD PROTECTION FOR EACH BLOWER. CONTROLLER SHALL BE ALLEN -BRADLEY SMC -FLEX, RATED 85A MINIMUM. PILOT LIGHTS ON OUTER DOOR INDICATING RUN AND FAULT CONDITIONS FOR EACH BLOWER. ALTERNATOR CONTROL CONTROL INTERFACE FOR PRESSURE TRANSMITTER. TOGGLE SWITCH DISCONNECT FOR 120V CONTROL POWER. 27 JUNE 2018 CARO''% SS%ptil%�Ly' SEAL 9504.641 GIN KVA LOAD LOAD SERVED WIRE BRKR CK" SIZE AMPS N0. .4 RECEPT 12 20 1 .5 AREA LIGHTS 10 20 3 .4 RECEPT CLARIFIER 1 8 20 5 MISCELLANEOUS 1.2 @ 3.0 CLARIFIER 1 10 20 9 @ - % _ - 16 SPACE ONLY 15 10.0 CP -W WASTE PUMPS 6 60 21 2@ 3 HP 36.0 CP -R RECYCLE PUMPS 1 125 4@ 7.5 HP SQUARE D TYPE NQ SURFACE MOUNTED 120/208V 3 PHASE 4 WIRE 400A BUSSES AND NEUTRAL 300A MAIN BREAKER ® BOTTOM PANEL SHALL BE RATED 22,000AIC NEMA 3R ENCLOSURE PANEL PC I #3 LOAD SERVED I I I --------- -------- ------ SPARE I--- I 4 20 SPARE MOTORS (NON -HVAC) #3 BARS J EQUIPMENT PAD 12"O.C. 3500psi CONCRETE EACH WAY ABC ;KT BRKR WIRE 40. AMPS SIZE LOAD SERVED KVA LOAD 2 20 SPARE - 4 20 SPARE MOTORS (NON -HVAC) 6 20 8 RECEPT CLARIFIER 2 .4 MISCELLANEOUS 1.2 @ 10 20 10 CLARIFIER 2 3.0 @ - % _ - 16 SPACE ONLY 22 100 3 CP -S SLUDGE PUMPS 22.0 2@ 10 HP LOAD TABULATION CATEGORY GROSS GROUT USE NET LIGHTING - @ - % _ - MOTORS (NON -HVAC) 74.0 @ - % = - MISCELLANEOUS 1.2 @ - % = - TOTALS 75.2 @ - % _ - 36" MIN NON -SHRINK GROUT ALTERNATOR LEVELING 6" SS NUT AND ANCHOR BOLT SPACER WEATHER SHIELD OF .25" FINISHED ALUMINUM PLATE FRAME OF WELDED 4" SQ ALUMINUM TUBE 8" MINIMUM 3" ABOVE FINISHED GRADE 12" MINIMUM — MINIMUM_ - 6'-0' (OR AS SHOWN ON PLAN) DETAIL - TYPICAL EQUIPMENT SHELTER NOT TO SCALE FLOW METER TRANSMITTERS WITH DISPLAY SCREENS PHOTOCELL LIGHTING PANEL CONTROL PC SWITCH WP R GFI '�j" o 8"x8 x6 NEMA 4X TERMINAL CABINET TCC. 24"x 18"x6". NEMA 4X CP -R CP -W TCC HUBS 1 I TIGHT TO RECYCLE TO WASTE PUMPS PUMPS 2"C FROM TO FLOW 1 "C TO LAB BLDG METERS CP -S EQUIPMENT SHELTER ESH-C1 NOT TO SCALE AIR GAPS FOR CABLES FROM WET WELL WP R GFI �j 8"x8"x6" NEMA 4X FROM PANEL CONTROL PANEL CP -S - - - - - EQUIPMENT CLARIFIER 1,' /Y�- _ _ _ = SHELTER 1"C FOR L_ - ESH-C2 COMMUNICATIONS. _ FROM CP -S TO I i , � I �y TERMINAL CABINET TCC1. / CLARIFIER CONTROL PANEL WITH I-,2HP 11 [1OHPINTEGRAL 1 J 4, i I //DISCONNECTWP GFI % i / PC -1 SLUDGE PUMPS 1"C TO TCC W I T H FLOW — ,� METER CABLES / V,u SCH §G -PVC I // 1171 LJ CONDUITS_ _ SUPPORTED ON -1�/2„C11/2" UNDERSIDE OF WALKWAY STRUCTURE 3/4'C FROM CLARIFIER 3HP 3HP CONTROL PANEL TO / / / / CABINET TCC EQUIPMENT / / / WET WELL SHELTER 1/2HP 71/2HP ESH-C1 / / I 1/2HP 71/2HP II CONTROL PA II CP -W --------- II �____---- CONTROL �--------- TERMINAL PANEL CP -R CABINET I I � ♦ � � � 1 %.1 rmum TCC iv rUMPS PC -3 TCC 11/2"C FOR EACH PUMP — 3/47C TO TCC TYPE LI PANEL IN WET WELL. CABLE AREA LIGHT PC �/ J `- — PROVIDED BY PUMP 2 #8 (CKT PC -5) + 000 SUPPLIER. 3 #10 (CKT PC -9) + VERIFY SIZE AND / #8 GND - 1"C / ROUTING PRIOR TO 1"C TO TCC ANY INSTALLATION. WITH FLOW METER 2"C TO TCC CABLES EQUIPMENT SHELTER ESH-C2 NOT TO SCALE FROM LAB BUILDING / WP 0 GFI I I 8"x8"x6" NEMA 4X FROM PANEL P FEEDER FROM TO TO BLOWERS SLUDGE THICKENING PRESSURE BUILDING SENSOR ELECTRICAL PLAN - CLARIFIER AREA SCALE: 1/8" = V-0" EQUIPMENT SHELTER ESH-B NOT TO SCALE NA MA CIRCUIT i I III ❑ I M I BREAKER L JjL_JL-J L_ CONTROL POWER o DISCONNECT u _ _ _J / CLARIFIER 2 CLARIFIER ��- CONTROL n(�f _pANEL WITH hINTEGRAL NP - QISCONNECT I I� I I SCH 80 PVC CONDUITS SUPPORTED ON I UNDERSIDE OF WALKWAY STRUCTURE I I I I I I I I I I I I II I PC -3 I TYPE P2 3/4 C TO TCC — — AREA LIGHT 2 #8 (CKT PC -6) + 3 #10 (CKT PC -10) + #8 GND - 1"C MOTOR CIRCUIT PROTECTORS - PILOT ---w- LIGHTS I TERMINALS FOR INCOMING LINE AND MOTOR CIRCUITS STEEL MOUNTING BLOWER CONTROL PANEL CP -13 NOT TO SCALE SOFT -START CONTROLLERS ALTERNATOR 1 11x CONTROL L_� I L -J I L -J r -SII II I XI I I I I III II I II I NA MA CIRCUIT i I III ❑ I M I BREAKER L JjL_JL-J L_ CONTROL POWER o DISCONNECT u _ _ _J / CLARIFIER 2 CLARIFIER ��- CONTROL n(�f _pANEL WITH hINTEGRAL NP - QISCONNECT I I� I I SCH 80 PVC CONDUITS SUPPORTED ON I UNDERSIDE OF WALKWAY STRUCTURE I I I I I I I I I I I I II I PC -3 I TYPE P2 3/4 C TO TCC — — AREA LIGHT 2 #8 (CKT PC -6) + 3 #10 (CKT PC -10) + #8 GND - 1"C MOTOR CIRCUIT PROTECTORS - PILOT ---w- LIGHTS I TERMINALS FOR INCOMING LINE AND MOTOR CIRCUITS STEEL MOUNTING BLOWER CONTROL PANEL CP -13 NOT TO SCALE SOFT -START CONTROLLERS LL r C D' 4 7 c LL c 4 a U LL U L L U O' LL LL L c L LL N VLT I I I I I I I I I VL WP PD -21 3#8+ #8 GND 1"C PD -7 VLT r. - - -- - -- - -- ---- /z//X/ 2"C TO TCD T ` ---- 4'/ OUTLETS ////// POLYMER POUMPS. COORDINATE FOR // LOCATION. /// HT ////// PROVIDE CAST BOX // WITH SUITABLE HUBS FOR CONNECTION ❑ ///// TO HEAT TRACE. //// TYPICAL WP JUNCTION BOX. STAINLESS STEEL. // / 8"x8"x6" �I //WP / / Gn TYPE P1 FLOODLIGHT FIXTURE ° FEEDER TO 3 #4 (CKT PD -34) + PANEL PD 4 #6 (CKTS PD -28,30) + / \ #6 GND - 2"C �� \ IN -GROUND FEEDER aa PULL BOX O CONTROL SYSTEM 2"C FOR TERMINAL CABINET CONTROLS IN -GROUND I TCH. 12"x12"x6" CONTROL 1"C — — — — HEADWORKS SYSTEM — — — — — CONTROL PULL BOX PANEL 3#4+4#6+ #6 GND - 11/2"C 27 JUNE 2018 CARp �•,�0FESS%0*,*-. rQ l: SEAL =�• 9504 V ON 1j111111110\ PROVIDE CAST BOX WITH SUITABLE HUBS FOR CONNECTION TO HEAT TRACE. TYPICAL I I I I I I I I I I HT PD -30 NEW HEADWORKS SCREW CONVEYOR ROTARY DRUM THICKENER 3HP 0 225A CIRCUIT BREAKER PD -11,13 TV PD -16,18 PUMP 3HP PD -9 PD-: CONTROL PANEL CP -B / 1 PD -4,6 EQUIPMENT SHELTER ESH-B I/ I/ / 1"C TO BLOWER CONTROL PANEL FOR CONTROL PANEL RING PD Ir _-j Ir _71 Ir �I I I I I I I ---- I--� ---- I r r r T- I I PRESSURE SWITCH ELECTRICAL PLAN - DIGESTER AREA SCALE: 1/8" = 1'-0" :I c I LL C L L. c L I r r 0C CISQ L a a L 7 a L LL c a Q 7 c LL c Q a U LL U C C r C L L U a LL LL L L L LL 27 JUNE 2018 \�\ 1 CARO''% 'SF ESS%p�l��y rQ l° SEAL 9504 �liS J°°FNG I IJ�: �- '�/ON L. IN -GROUND PULL BOX EXISTING OVERHEAD FEEDER 1 EXISTING OVERHEAD FEEDER 2 EXISTING OVERHEAD FEEDER 3 ___ r__ _____dill._____111116._________________ �,_,_ _____ dh SLUDGE PUMP CHLORINE SLUDGE PUMP BUILDING 2 BUILDING I BUILDING 3 EXISTING AERATION I I I BLOWER CONTROL ON NELS POLES MOUNTED / I EXISTING TROUGH [PANEL PANEL I MOTOR CONTROL FPANELCENTER EXISTING SWITCH PB2 EXISTING SWITCH CL62 I \O EXISTING SWITCH MCC3 PB3 100A 3P EXISTING 200A 3P EXISTING�g 200A 3P EXISTING NEMA 4X. I NEMA 4X. I NEMA 4X. 100A FUSES 150A FUSES EXISTING TROUGH 2O0A FUSES EXISTING Ll L L L L-- L I I I 25HP 25HP I 25HP 25HP I 25HP 25HP AERATION BASIN 1 AERATION BASIN 2 AERATION BASIN 3 I I I I I I I I I L, _ _ _ _ _ _ _ _ _ _ _ _ _ J PROVIDE WIREWAY FOR FEEDER CONNECTION TO TOP OF SWITCHBOARD l EQUIPMENT SHELTER NEW HEADWORKS NEW SLUDGE THICKENING BUILDING ESH-B SWITCHBOARD TRANSFER SERwCE HEADWORKS SYSTEM BLOWER CONTROL PANEL MDP SWITCH DISCONNECT CONTROL PANEL EXISTING ATS MCB FPANEL 25' LENGTH EXISTING EXISTING 1 MAIN BREAKER DISCONNECTS AND PANEL #2 BARE CU GND MOTOR CIRCUIT EXISTING n n CONTROLLERS FOR 250A 3P 240V PD EMBEDDED IN 250A MAIN PROTECTOR TVSST - EXISTING SCREW CONVEYOR CIRCUIT BREAKER. CONCRETE FOOTING. BREAKER r1 1 r1 AND RAKE LIFT u NEMA 1 ENCLOSURE. � I BOND TO SOFT -START BLOWER 1 o N WP c REINFORCING WP JUNCTION BOX. CONTROLLER GFI STEEL. STAINLESS STEEL. 1600A WP JUNCTION BOX. GROUND BAR. STAINLESS STEEL. BOND TO ALL 4 #1/0 + 6"x6"x4" n r'1 E LB's 12"x12"x6" ENCLOSURES. JUNCTION BOX. #6 GND 20HP PULL BOX PROVIDE INSULATED I I GROUND BAR. WP RMC "C #4 CU BOND TO DISTRIBUTION BLOCKS GFI WEATHERPROOF 2 i REINFORCING STEEL FOR FEEDER PULL BOX OF HEADWORKS CONNECTIONS. I STAINLESS � RMC � BOND TO ALL STEEL I STRUCTURE ENCLOSURES. �•—•� FROM UTILITY STEEL I SCH 80 `J I TO BLOWER 2 1AOQA �Inln TRANSFORMER RMC 4 PVC II _ TO BLOWER 3 TO INFLUENT FROM 400 KW IN -GROUND PUMP STATION ,OOJ1 1000A GENERATOR PULL BOX 3 250 KCMIL + CONCRETE ENCASEMENT 3 #4 + #6 GND #1/0 NEUT + 3 #4 (CKT PD -16) + 3 #4/0 + REQUIRED FOR ALL 4 #10 + 11/2"C #1/0 GND - 3"C #3 GND UNDERGROUND CONDUITS #10 GND TO PRESSURE INDICATES NOMINAL EACH OF TWO PARALLELS 2 #6 (CKT PD -12) + 21/2"C3/4 C SWITCH. 3/4"C FEEDER RATING OF EXISTING #6 GND - 2"C #4BARE CU GND TO 10'-0" MIN DRIVEN ELECTRODES. 10'x3/4" COPPERCLAD STEEL EQUIPMENT EQUIPMENT 120V PHOTOCELL SHELTER ESH-C1 CLARIFIER AREA SHELTER ESH-C2 CONTROL. TORK OR EQUAL. -----mm-op F—cP-R CP -W WP ENCLOSURE PANEL CP -S WITH 3 -POSITION (ON -OFF -AUTO) PC , , , CABLES FROM CONTROL 100A MAINLIGHTING 7FLSWITCH FOR 1' k l� l� PANELS TO PUMPS TO BE PROVIDED BY PUMP SUPPLIER. BREAKER CIRCUIT �� ��� COORDINATE AND VERIFY UIT SIZES ED DINSTALLATION. IRTO LIQUIDTIGHT GWD 171 PRIOR ANY METAL FLEX G I WP JUNCTION BOX. 1 /2"C TO EACH 1 "C TO EACH 10HP STAINLESS STEEL. WATERTIGHT OF FOUR RECYCLE OF TWO WASTE 8"x8"x6" CABLE HUBS PUMPS. PUMPS. 71/2 HP EACH. 3 HP EACH. JUNCTION BOX NEMA 4X STAINLESS STEEL WET WELL STAINLESS #4 BARE CU GND TO STEEL CHANNEL DRIVEN ELECTRODES. SUPPORT 3 250 KCMIL + 10'x3/4" COPPERCLAD 3 #3 + 2 #10 + #1/0 NEUT + STEEL #6 NEUT + #10 GND #1 3" /0 GND - C 10'-0" MIN #%2"C D EACH OF TWO PARALLELS STEEL RMC SCH 80 PVC CKTCPC-1 1"C TO EACH OF TWO SLUDGE PUMPS TO TYPE P2 AREA LIGHTS - 27 JUNE 2018 \�\ 1 CARO''% 'SF ESS%p�l��y rQ l° SEAL 9504 �liS J°°FNG I IJ�: �- '�/ON L. IN -GROUND PULL BOX EXISTING OVERHEAD FEEDER 1 EXISTING OVERHEAD FEEDER 2 EXISTING OVERHEAD FEEDER 3 ___ r__ _____dill._____111116._________________ �,_,_ _____ dh SLUDGE PUMP CHLORINE SLUDGE PUMP BUILDING 2 BUILDING I BUILDING 3 EXISTING AERATION I I I BLOWER CONTROL ON NELS POLES MOUNTED / I EXISTING TROUGH [PANEL PANEL I MOTOR CONTROL FPANELCENTER EXISTING SWITCH PB2 EXISTING SWITCH CL62 I \O EXISTING SWITCH MCC3 PB3 100A 3P EXISTING 200A 3P EXISTING�g 200A 3P EXISTING NEMA 4X. I NEMA 4X. I NEMA 4X. 100A FUSES 150A FUSES EXISTING TROUGH 2O0A FUSES EXISTING Ll L L L L-- L I I I 25HP 25HP I 25HP 25HP I 25HP 25HP AERATION BASIN 1 AERATION BASIN 2 AERATION BASIN 3 I I I I I I I I I L, _ _ _ _ _ _ _ _ _ _ _ _ _ J PROVIDE WIREWAY FOR FEEDER CONNECTION TO TOP OF SWITCHBOARD l EQUIPMENT SHELTER NEW HEADWORKS NEW SLUDGE THICKENING BUILDING ESH-B SWITCHBOARD TRANSFER SERwCE HEADWORKS SYSTEM BLOWER CONTROL PANEL MDP SWITCH DISCONNECT CONTROL PANEL EXISTING ATS MCB FPANEL 25' LENGTH EXISTING EXISTING 1 MAIN BREAKER DISCONNECTS AND PANEL #2 BARE CU GND MOTOR CIRCUIT EXISTING n n CONTROLLERS FOR 250A 3P 240V PD EMBEDDED IN 250A MAIN PROTECTOR TVSST - EXISTING SCREW CONVEYOR CIRCUIT BREAKER. CONCRETE FOOTING. BREAKER r1 1 r1 AND RAKE LIFT u NEMA 1 ENCLOSURE. � I BOND TO SOFT -START BLOWER 1 o N WP c REINFORCING WP JUNCTION BOX. CONTROLLER GFI STEEL. STAINLESS STEEL. 1600A WP JUNCTION BOX. GROUND BAR. STAINLESS STEEL. BOND TO ALL 4 #1/0 + 6"x6"x4" n r'1 E LB's 12"x12"x6" ENCLOSURES. JUNCTION BOX. #6 GND 20HP PULL BOX PROVIDE INSULATED I I GROUND BAR. WP RMC "C #4 CU BOND TO DISTRIBUTION BLOCKS GFI WEATHERPROOF 2 i REINFORCING STEEL FOR FEEDER PULL BOX OF HEADWORKS CONNECTIONS. I STAINLESS � RMC � BOND TO ALL STEEL I STRUCTURE ENCLOSURES. �•—•� FROM UTILITY STEEL I SCH 80 `J I TO BLOWER 2 1AOQA �Inln TRANSFORMER RMC 4 PVC II _ TO BLOWER 3 TO INFLUENT FROM 400 KW IN -GROUND PUMP STATION ,OOJ1 1000A GENERATOR PULL BOX 3 250 KCMIL + CONCRETE ENCASEMENT 3 #4 + #6 GND #1/0 NEUT + 3 #4 (CKT PD -16) + 3 #4/0 + REQUIRED FOR ALL 4 #10 + 11/2"C #1/0 GND - 3"C #3 GND UNDERGROUND CONDUITS #10 GND TO PRESSURE INDICATES NOMINAL EACH OF TWO PARALLELS 2 #6 (CKT PD -12) + 21/2"C3/4 C SWITCH. 3/4"C FEEDER RATING OF EXISTING #6 GND - 2"C #4BARE CU GND TO 10'-0" MIN DRIVEN ELECTRODES. 10'x3/4" COPPERCLAD STEEL