HomeMy WebLinkAboutNC0004944_Determination_20180705Performance Fibers
NC0004944
Average Flow from 2008 - 2013: 0.39 MGD
The process wastewater flow at this facility is split between two 40 CFR 414 subparts, subparts C and D.
40 CFR 414.31 (Subpart C - All units are mg/L)
Daily Max I M!36
Av .
BODS 48
TSS 115
40 CFR 414.41 (Subpart D - All units are mg/L)
Daily Max Mf
.
BODS 64
TSS 130
Process Flow applicable to subpart C: 0.047 MGD
Process Flow applicable to subpart D: 0.215 MGD
Subpart C Allocation - lbs/day
Daily Max Mon. Av .
BODS 18.81504 7.05564
TSS 45.0777 14.11128
Subpart D Allocation - lbs/day
Dail Max Mon. Avg.
BODS 114.7584 43.0344
TSS 1 233.103 71.724
Domestic Allocation (Q = 41,000 gpd) - Assuming secondary limits - lbs/day
Daily Max M!n.Av
.BODS 15.3873 182TSS 15.3873 182
Total Allocation (Sum of C, D, and Domestic) - lbs/day
Daily Max I Mf60
.
BODS 149 TSS 294
Existing Allocation
Daily Max Mon. Avg.
BODS 187 75
TSS 369 120
Mark McIntire
8/12/2004