Loading...
HomeMy WebLinkAbout20180612 Ver 1_More Info Received_20180629Homewood, Sue From: Sent: To: Cc: Subject: Sue, Gregory Hoffman <ghoffman@cdcgo.com> Friday, June 29, 2018 4:09 PM Homewood, Sue Clement Riddle; Alea Tuttle; Patrick Bradshaw [External] DWR 20180612 Western Carolina University Master Plan Improvements Good afternoon. I received a copy of your comment letter for the WCU Campus Master Plan project and have submitted a Stormwater application to Chonticha McDaniel as requested. You can download a copy of the submittal at the link below. https://cdcwnc.sharefile.com/d-s654980af7O848518 Additionally, I'll send you a hard copy on Monday. Have a nice weekend, Thanks, Greg Gregory Hoffman, PE Civil Design Concepts, P.A. o. (828) 252-5388 c. (828) 707-1334 Office locations: 168 Patton Avenue Asheville, NC 28801 1 52 Walnut Street — Suite 9 Waynesville, NC 28786 Mailing address: P.O. Box 5432 Asheville, NC 28813 www.cdc og com R� Privileged and Confidential: The information contained in this email message and any attachments is confidential information intended only for the use of individuals or entities named above. If the reader of this message is not the intended recipient you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited If you have received this email in error, please notify us immediately by email at the originating address. WCU-CENT DEVELOPMENT DATA OWNER/DEVELOPER: WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CONTACT: CURTIS MONTEITH (828) 227-7442 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 CONTACT: GREG HOFFMAN, P.E. (828) 252-5388 W 000 00 (D LU 00 N L W LU r N F- V� W N N 04 0000 N N CD a Z N N co Z Z O J N N W W N N J 00 OD W J OV W ¢> W x a w Z PHASE 2 EROSION CONTROL AND GRADING PLAN 00 2 0 LL CD W O LL Q a Z Q a C702 3 C921 3 C931 N Ln F AL DRIVE PARKING � 3 CULLOWHEE, NORTH CAROLINA 3: m Dee C) J O 0 It 00 T N U W N Z W U J N J W m U Z J J Q J Q m m Z D m O U = m wCK- Of O Z p Q w m p � p EK� PREPARED FOR:0 0 1�,E� c, WESTERN CAROLINA UNIVERSITY Li.l 3476 OLD COLLOWHEE ROAD o o N 000 CULLOWHEE NORTH CAROLINA 28723 Nr-� d... = I CURTIS MONTEITH (828) 227-7442 INDEX OF SHEETS Sheet No. Title C000 COVER SHEET Z SURVEY (BY OTHERS) C101 EXISTING CONDITIONS AND DEMOLITION PLAN C201 SITE AND ZONING COMPLIANCE PLAN C301 PHASE 1 EROSION CONTROL PLAN C302 PHASE 2 EROSION CONTROL AND GRADING PLAN C401 FINE GRADING AND STORM DRAINAGE PLAN C701 SEWER EXTENSION PLAN C702 SEWER PROFILES C921 SITE DETAILS C931 GRADING DETAILS C932 EROSION CONTROL DETAILS C941 STREAM CROSSING DETAILS C942 STORM DRAINGE DETAILS C971 SEWER EXTENSION DETAILS ES100 ELECTRICAL SITE PLAN, NOTES, SCHEDULES, & MISC. DETAILS ES101 ELECTRICAL SITE PLAN, NOTES, SCHEDULES, & MISC. DETAILS ES102 ELECTRICAL SITE PLAN, NOTES, SCHEDULES, & MISC. DETAILS N us 107 cFti c OQ umi o CSE SP.4 r �� �\ o ti to SUBJECT PROPERTY 01 10 l c�UB OR . O cG�o VICINITY MAP (NOT TO SCALE) Know what's below. 0111 before you dig. \ �P�oo�yy�o,, ° o 0) Vit° s oW N M N "pia v� o ° o G�F'G 0 Z M� L.L a Q z WQ J 0 0 O Q z w J L,d 0 a J J � M I..L U i Z W `f OfW z UQ ' z J 0 W W 0 U O Ll m W > z W LLJ � U) 0 LLJ DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET C000 NOTES: 1. THIS SURVEY IS BASED ON DEED AND EXISTING MONUMENTATION AS SHOWN. 2. PARCEL MAY BE SUBJECT TO EASEMENTS, RIGHT-OF-WAYS, RESERVATIONS AND RESTRICTIONS WRITTEN AND UNWRITTEN; RECORDED AND UNRECORDED. 3. THE CERTIFICATION SHOWN HEREON IS NOT A CERTIFICATION OF TITLE, ZONING OR FREEDOM FROM ENCUMBRANCES. 4. THIS SURVEY WAS PREPARED WITHOUT BENEFIT OF ABSTRACT TITLE AND ALL MATTERS OF TITLE SHOULD BE REFERRED TO AN ATTORNEY-AT-LAW 5. ALL DISTANCES ARE HORIZONTAL UNLESS OTHERWISE NOTED. 6. COPYRIGHT ®, JOEL JOHNSON LAND SURVEYING. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, ADDITIONS OR DELETIONS TO THIS DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF THE LAND SURVEYOR IS PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, MARKED WITH AN ORIGINAL SIGNATURE AND SEAL OF THE SURVEYOR SHALL BE CONSIDERED TO BE VALID TRUE COPIES. 7. TRAVERSE ADJUSTED BY COMPASS METHOD TO 1: 18,136. 8. PROPERTY HAS NOT BEEN INSPECTED FOR WETLANDS OR FLOOD HAZARDS. 9. ALL ADJOINING PROPERTY INFORMATION WAS TAKEN FROM CURRENT LAND RECORDS INFORMATION AS OF DATE OF SURVEY BUT IT SHOULD BE NOTED THAT ALL PUBLIC LAND RECORDS INFORMATION MAY NOT BE CURRENT OR UP TO DATE. 10. ELEVATIONS ARE BASED ON NAVD 88 (GEOID 12B). 11. THE ORIENTATION OF THE SURVEY IS GRID NORTH AND THE COORDINATES ARE BASED ON THE NORTH CAROLINA STATE PLANE COORDINATE SYSTEM, NAD 83 (2011). 12. UNDERGROUND UTILITIES AND IMPROVEMENTS NOT READILY VISIBLE WERE NOT LOCATED. 13. THIS MAP WAS PREPARED FOR THE PURPOSE OF SHOWING A BOUNDARY SURVEY AND TOPOGRAPHIC CONDITIONS OF SIX EXISTING LOTS WHICH ARE SHOWN AS TWO TRACTS. 14. APPARENTLY THE MANHOLES DESIGNATED AS "5 E/P" WERE BURIED OR OBSCURED. THEIR LOCATIONS WERE CALCULATED FROM THE EASEMENT PLAT OF SURVEY SHOWN IN REFERENCE # 1. 15. INGRESS/EGRESS RIGHTS ALONG EXISTING SOIL ROAD MAY EXIST IN FAVOR OF WARD. CERTIFICATE OF APPROVAL FOR RECORDING I CERTIFY THAT THE PLAT SHOWN HEREON COMPLIES WITH THE SUBDIVISION AND MOUNTAIN AND HILLSIDE DEVELOPMENT ORDINANCE AND IS APPROVED FOR RECORDING IN THE REGISTER OF DEEDS OFFICE. - Planning Director or Designee - Date CERTIFICATE OF APPROVAL FOR RECORDING I CERTIFY THAT THE PLAT SHOWN HEREON COMPLIES WITH THE WATERSHED PROTECTION ORDINANCE AND IS APPROVED FOR RECORDING IN THE REGISTER OF DEEDS OFFICE. - WATERSHED ADMINISTRATOR - DATE NOTICE: THIS PROPERTY IS LOCATED WITHIN A PUBLIC WATER SUPPLY WATERSHED -DEVELOPMENT, RESTRICTIONS MAY APPLY. STATE OF NORTH CAROLINA COUNTY OF JACKSON FILED FOR REGISTRATION AT THE DAY OF_ RECORDED IN PLAT CAB. - REGISTER OF DEEDS - STATE OF NORTH CAROLINA COUNTY OF JACKSON O'CLOCK M THIS .2017 AND AT SLIDE I, REVIEW OFFICER OF JACKSON COUNTY, CERTIFY THAT THE MAP OR PLAT TO WHICH THIS CERTIFICATION IS AFFIXED MEETS ALL STATUTORY REQUIREMENTS FOR RECORDING. - REVIEW OFFICER - DATE REFERENCES: 1. Easement Plat of Survey for Tuckaseigee Water and Sewer Authority by Joel Johnson Land Surveying, Inc. dated November 16, 2005 and recorded in Plat Cabinet 14, Slides 646-647. 2. Deed of Easement between Davis, Mildenhall & Moses and Tuckaseigee Water and Sewer Authority dated January 23, 2006 and Recorded in Deed Book 1568, Page 127. 3. Right -of -Way Deed between Brown and Norton dated April 9, 1960 and recorded in Deed Book 238, Page 202. 4. Deed between Carrie S. Bryson and H. Carson Bryson dated March 8,1958. 5. Deed between Holmes Bryson etal and Carrie Bryson dated March 12, 1946 and recorded in Deed Book 168, Page 7. 6. Unrecorded Plat of Survey for Frank H. Brown by James R. Davenport and Associates, Inc. dated April 5, 1982, drawing # J-255. 7. Plat of Survey for Stone House Associates by John W. Jurss dated March 22, 1999 and recorded in Plat Cabinet 9, Slide 602. 8. Plat of Survey for the subdivision of the Bryson Land dated 1926 recorded in Plat Cabinet 2, Slide 42. 9. Plat of Survey for the State of North Carolina by Joel Johnson Land Surveying, Inc. dated April 29, 2015 and recorded in Plat Cabinet 21, Slide 447. 5/8" Rebar 1-17 ound with Ca 5/8" Reba d Ca l v = 2218.0 Central Drive NCSR 1169 R,'ght_of Way varies H 77-77274'CM7P - Western Carolina University - �\ PIN 7559-43-3182 Deed Book 712, Page 704 with Johnson Cap 5/8" Rebar Found d , N �c P ; O 514°301501E P P o rT / 10490 3d / Inv = 219. PE / :SSS ^' SMH 3 PE 1 a gl 1 L $'. 1 V) Tract A 4.52 Acres As Calculated by Coordinate Computations Deed Book 2053, Page 269 Deed Book 1968, Page 71 Deed Book 1437, Page 403 Deed Book 2177, Page 214 Deed Book 1437, Page 403 PIN 7559-42-1855 PIN 7559-42-3668 PIN 7559-42-4547 PIN 7559-42-4744 PIN 7559-42-4944 PIN 7559-43-4025 Nail Found azo J Asp a L - A A Calls around Tract A Course IPS - 1 Top = 222. d L2 5 57046'15" W 121.09' L3 Inv = 498.38' Central Drive N 81010'00" E 103.63' L5 N 81010'00" E 29.01' NCSR 1169 N 09050'05" E 7.26' L7 L8 N 18055'00" W 18.14' 60 Right of Way I L9 N 00013'15" E 11.94' L10 N 28033'50" W 35.76' L11 N 52011'05" W 5.41' L12 2" Open Top 15.58' A N 71036'00" E N 71036'00" E 132.57' 63.00' L14 Pipe Found A° A L16 5 21036'20" E 50.09' L17 Rad: 200.00' Tan: 53.68' Chd: 5 06034'50" E A: 104.89' CA: 30002'55" 103.69' L18 5 08027'05" W 211.47' L19 �S l� dTop - 2117 L20 5 09010'00" W 103.20' L21 N 80008'00" W Inv nt 221. L22 A 'A ,o- A - DI ove rate c�t installed A Gravel Road A Inv t = 14.48 Existing Fence Line -x x x 11' A A d� ld A A Existing Creek A - S.X w ow Overhead Wires ow 5/8" Rebar FoundTt --SS-----SS-- A ELI. Elev = 2211.42 Property Corner Found - Western Carolina University - �\ PIN 7559-43-3182 Deed Book 712, Page 704 with Johnson Cap 5/8" Rebar Found d , N �c P ; O 514°301501E P P o rT / 10490 3d / Inv = 219. PE / :SSS ^' SMH 3 PE 1 a gl 1 L $'. 1 V) Tract A 4.52 Acres As Calculated by Coordinate Computations Deed Book 2053, Page 269 Deed Book 1968, Page 71 Deed Book 1437, Page 403 Deed Book 2177, Page 214 Deed Book 1437, Page 403 PIN 7559-42-1855 PIN 7559-42-3668 PIN 7559-42-4547 PIN 7559-42-4744 PIN 7559-42-4944 PIN 7559-43-4025 Nail Found azo J Asp a L - A A Calls around Tract A Course Bearing Distance L1 5 85037'00" W 144.48' L2 5 57046'15" W 121.09' L3 N 11003'35" W 498.38' L4 N 81010'00" E 103.63' L5 N 81010'00" E 29.01' L6 N 09050'05" E 7.26' L7 L8 N 18055'00" W 18.14' N 41045'25" W 18.87' L9 N 00013'15" E 11.94' L10 N 28033'50" W 35.76' L11 N 52011'05" W 5.41' L12 N 24042'05" W 15.58' 1_13 N 71036'00" E N 71036'00" E 132.57' 63.00' L14 L15 N 71035'30" E 114.38' L16 5 21036'20" E 50.09' L17 Rad: 200.00' Tan: 53.68' Chd: 5 06034'50" E A: 104.89' CA: 30002'55" 103.69' L18 5 08027'05" W 211.47' L19 5 87051'25" E 24.81' L20 5 09010'00" W 103.20' L21 N 80008'00" W 25.10' L22 5 06051'35" W 174.93' Asphalt L A =L P4 - A A _ krass JX 1 d A 1 5/8" Rebar Set with Cap Grid Coordinates 1 A� � N = 592,555.34' E = 754,586.49' A A A Elevation = 2235.07' PE --SS c/o PE Gravel i �- 91 ras SS' PE - E PE 1 Story o 0 s Dwelling Sp in. Head o �- GP5 Control Point See Note 14J =B d T / ce Sid 59 Grid Coordinates e PIC SMH-6 - N = 593,671.94'5 8" Rebar Set d _SS --�- E = 754,278.16' PIC L9 with Cap 56 _ _SS --SS--- Elev = 219134 3d 3.97 ___S � P PE P d GPS Control Metadata (1) Class of survey: A (2) Positional accuracy: 0.037ft @ 95% Confidence (3) Vertical Accuracy: 0.066ft @ 95% Confidence (4) Type of GPS field procedure: OPUS Static (5) Dates of survey: May 4, 2017 (6) Datum/Epoch: NAD 83 (2011) (EPOCH: 2010.0000) (7) Published/Fixed-control use: FRKN, NCBC, P779 & HAYW (8) Geoid model: 12B (9) Average combined grid factors: 0.99977164 (10) Units: US Survey Feet I, R. JOEL JOHNSON, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (JACKSON CO. BK. 1437, PG. 403, BK. 1968, PG. 71 AND BK. 2053, PG. 269); THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED AS DRAWN FROM INFORMATION AS SHOWN ON PLAT; THAT THE RATIO OF PRECISION AS CALCULATED IS 1 : 12,673; THAT THE CONTOURS SHOWN AS BROKEN LINES MAY NOT MEET THE STATED STANDARD; AND ALL COORDINATES ARE BASED ON NAD 83 (2011) AND THE CONTOURS ARE ON NAVD 88 (GEOID 12B); THAT THE VERTICAL CLOSURE WAS 0.011' BEFORE ADJUSTMENTS. THAT THIS CERTIFICATION IS FOR THE TOPOGRAPHY AND EXISTING ABOVE GROUND SITE CONDITIONS AS SHOWN AND THAT THIS PLAT MEETS THE REQUIREMENTS FOR A CLASS C SURVEY; THAT THE SURVEY IS OF AN EXISTING PARCEL OR PARCELS OF LAND AND DOES NOT CREATE A NEW STREET OR CHANGE AN EXISTING STREET PER SECTION (f)(11)c1; THAT THIS PLAT WAS PREPARED IN ACCORDANCE WITH G.S. 47-30 AS AMENDED. WITNESS MY ORIGINAL SIGNATURE, REGISTRATION NUMBER AND SEAL THIS 11th DAY OF JULY, A.D., 2017. \��Illllllli�� \ �N CAR . \ �� FESS/0 --/2� SEAL r L-3882 0 ' PSUR0F� 'g� , J00....1o1s R. JOEL JOHNSON REGISTRATION NUMBER L - 3882 3 _ - 5/8" Rebar �.,�, `�f IC 3d 3d 55____ PE PE / P Grass I�a Found with Cap -� SS_____ SS -5 PE P Elev = 2190.84 12 SMH--4PE E 1 / Q� PE PE PE J 1 / Top Culvert = 2184.80 a a / i /Qras � Mob11e Nome /QAl /Q 3i U ow - d _ ee Note 14 °w / 20' (10' each side of centerline) \\e Nome o 3 Gravel Sewer Easement (Typical) Mob 5/8" Rebar Set 6 Tie with Cap 5 81010'00"W t State maintenance ends at 10.01' Ward's property line. L3Z / is P` ' O W See00te15 5/8" Rebar Set 50'1 Road sp -Ward- with Cap PIN 7559-43-1131 Inaccessible Point =_- Deed Book 545, Page 421If 5/8" Rebar%f� Found zx z �O V Shed rr----� _ice � F1 - 5F F S ' � E all � Railroad Spike Set Elev = 2221.61 -_ = �= - =_- =----- Due i - 'i ' � / j � � / •tom'- --__-- - ___ _ �� �\ d / Due to the extremely dense vegetation and ! / // �d o �d� Id ld0 ld Id adverse terrain in this area, a field survey _ / �d d Fence Fence Fence Fence could not beerformed. The DASHED Fence Fence Fence L28 P \ contours shown in this area were computed 5/8" Rebar Set L29 3/8" Rebar Found Post post Post Post Post Post Post using Bare Earth LiDAR data obtained with Cap Elev = 2263.57 from the Flood Risk Information System website. These contours may not meet \ - Brown - accuracy standards and should NOT be use for design or construction. These contours PIN 7559-32-8461 should be used for planning purposes only. - Western Carolina University - \ Deed Book 1176, Page 746 PIN 7559-23-1452 \ Deed Book 427, Page 399 \ Revised Oct 2, 2017 to show topographic information on filled area 40' 20' 0 40' 80' Scale In Feet Graphic Scale 1" = 40' °D Tie from Point on Property Line N 07°23'35"W 7.14' to Sewer Manhole o 3a 20' (10' each side of centerline) -SS--� Sewer Easement (Typical) --- - ----- Point B SMH-1 PE PE PE PE - PE 1 01 Hl - Clayton - w PIN 7559-42-4323 Deed Book 01E, Page 160 5/8" Rebar Found Elev = 2204.23 00 J� /J ?i 1 �UP r 5/8" Rebar Found illElev = 2226.56 / d UP _ SS- E Ed Norton Road NCSR 1168 --See Note 60' Right of Way Gravel 20' (10' each side of centerline) State maintenance ends at Sewer Easement (Typical) Ward's property line. Tract B Hwy. 107 To Sylvia 7. 77 Acres As Calculated by Coordinate Computations 26 Deed Book 2053, Page 269 L PIN 7559-42-1855 5/8" Rebar Set with Cap a N Fence 5/8" Rebar Set Post with Cap - Bryson - PIN 7559-42-1661 PIN 7559-42-1512 Deed Book 13E, Page 305 BEFORE YOU DIG STOP Distance CALL 1 800 632-4949 N.C. ONE -CALL CENTER www.NC811.ORG Plat Cab. , Slide Cullowhee 0/ o ��eeR Tuckasegee River a Project SI to 0 0 z N Q h N h z A on p0 P� Hwy. 107 To East LaPorte LOCA TION MAP NOT TO SCALE Calls around Tract B Course Bearing Distance L23 5 83000'00" W 10.03' L24 5 11003'35" E 282.55' L25 L26 5 71035'50" W 114.01' 5 17052'50" E 9.50' L27 5 75007'10" W 104.89' L28 N 00050'00" W 330.00' L29 L30 N 00050'00" W 70.71' N 43001'55" E 180.72' L31 L32 5 13050'00" E 22.05' 5 13050'00" E 165.67' Calls along existing sewerline Course Bearing Distance 51 N 01041'55" W 275.83' 52 N 15002'40" W 259.03' 53 N 80017'35" W 66.36' 54 5 56028'15" W 42.47' 55 5 05025'20" E 107.11' 56 5 05052'40" E 230.95' 57 1 5 80005'3511 W 74.89' 58 5 10018'20" E 157.63' 59 5 11024"2"' E 75.75' Sewer Manhole Table Sewer Manhole # Rim Elev Invert SMH-1 2211.19 2205.29 SMH-2 2203.87 2195.27 2188.61 SMH-3 2198.00 SMH-4 2190.72 2182.19 SMH-5 2193.35 2186.65 SMH-6 2204.41 2195.41 PL Property Line R/W Right of Way Adjoining Property Line PE -PE Easement -PE - • - • • - Tie Line - 2240 5 Foot Contour (Old) 1 Foot Contour (Old) 2240 5 Foot Contour (New) 1 Foot Contour (New) TB TB TB Top of Bank BB BE BB Bottom Of Bank Asphalt Road Gravel Road x Existing Fence Line -x x x Existing Creek - ow Overhead Wires ow --SS-----SS-- Existing Sewerline Property Corner Found 5/8" Rebar Set with Cap o PIC Point In Creek ® GPS Control Point B FFE Finished Floor Elevation 0' UP Utility Pole t LP Light Pole ® Power Transformer O TP Telephone Pedestal r9 WM Water Meter DQ WV Water Valve 4- Fire Hydrant QS Sewer Manhole E/P SMH from Easement Plat c/o Sewer Clean Out ® DI Drop Inlet 0 CB Catch Basin tV1 �1J • r� N � • rl U r� • rl O ctn `�/�.! O � ) -I v c� �--� ct O O a U �- O L ) L �Qt\• o c = E c Z a y H U L X ¢ _ 3 ro x O d L v' a o O L oU L t . Z N o ° NoQ ; sz •O > Z H o U ess c OL 3 3 %n t o O� _ d > > a vvv� o ^ao a -- u0 LL 000 +- N o C N c o t iv obi •oaos i' } 6 N in deco 0 t = _ a L O C oZ~ In s = O o s 6 'L � to c o ul U V C� C: �>- U > a M N 7 v C N } Oa L v O� O I_ o N �o > (\J 'n 'n I I L L a T . > h of a L a V) a Q a Z } z } Li 0- LO L in in t N o "o O m NI �I.- in N N N N s0000 h W o d yZ L o._- t Q co u- LL u vv a d } 610 a 3 L — Ward — \ Deed Book 545, Page 421 \ PIN 7559-43-1131 EXISTING OFFSITE MOBILE HOME (TYP) y \\ V� 1 o WETLAND TO I�I\III\\VAA I�II1� EXISTING PROPERTY LINE (TYP) _ V� I 1111 A11 V�1 \III 1V\VAA���wA EXISTING TROUT BUFFER (TYP) V II\111 II 1 1 Ill��� \\1 IIII I L\V\\ \v VA\ �A\\ OH - OH — Western Car lina Jnwersity — \\\\ ' ��VAA�\� AAVAV�\� IIII�I I � �� \ PROPOSED LIMITS OF DISTRUBANCE (TYP) Deed B 4 Pag ti9 \ \ \���� PIN v wyv� wvv y vtiv \ P� �\VA VA\\VA P\ 77-y �\ \ �,01 \y—IVA\V�V�VA I EXISTING SEWER LINE TO BE REMOVED AND REPLACED (TYP) _ �V\�A�� / } \�\\\ 11\mI\ ,� I \ 1 11111111``\ �jllllll 11 1111111 111 \r� I�IIn 1101 EXISTING SEWER EASEMENT TO BE ABANDONED (TYP) \ \ 1 / i \\ \ I \ III\I\`l \\I III �III�II I ca \\ \ \ �'' ���IlllA�Ijlllll lll�l IIII ll/ � \\ \ I) � I I 1\�VI111111 I SII IIIIIIIIIIIIIIIIIIIIIIIIIIII ✓� , _ I I / III 1 I11111�II11��1111�'', 'j11` \\\ �\\\ \ IIIII,�llllllllll 11 II 1111 IIIIIIIII / EXISTING WETLAND TO BE REMOVED \\ II I �\1I111111�11 / A11 I lllir ��jlll� I I 1 \� \ \\\\\\\I\\11111111 IIIIII I IIII r — / 11111 II IIIIII \ '\ \\\\\\\ \I\\\;111 I I\III 1111j1 I \\ 111 I / II Illllllllil �! NC DOT RIGHT OF WAY TO BE ABANDONED APPROXIMATE LOCATION OF PROPOSED PROPERTY LINE \ \(N V \ 0 \O \ \ diP Western Carolina University - Deed Book 712, Page 704 Pini 7559-11-3182 I ii`Cii/// \ / a I J ' I IIIIII111�11111111\I � I \ �' / I / V, 11 IIIIIIIIIII \v \ �V AV A A �IIII�IIIIII�I� IIII'111I1 vv \� 0 1 I �\ i I11111�111111111�'III�I v / ��v� ��' / yI111�1� �III�IIIIIIIII � I j ��� I� , �� �'� 1111111 1111 IIIIIIIII v � � � I I / ��� I 11111 11'I'll�lllllll�lllljl\ � \ � / I II III IIIIIII'I11111111111 \\ \\ i / / `_ 1 II 1111 11� I 1111 IIII � � � � � II I II� III IIIIIIIIIIID / 1� 1 b 0, 111I1'111II��II11I11 � / -- I ;IIIIII IIII IIII IIII I VIII I II IIIIII \' /I IIII l I I I I II I 1 I , /�� VIII II IIII IIII IIII IIII IIII IIII I / � � IIII; II��IIIIII,I,,II,II11111111111111 � �\ / � I I � � � i II IIJ 111111 IIII11jIIIIIOI / \ \ / � / � ; ; � I 1111111111!%1 jjlI�I�I�III�I1, �IIIII11111I11III II��II 11 11 A ��I���I IIS VA ` ��I�,✓��'✓ IIjIj��II IIII 111 I I �II11�1111�1111------I I I I I I/ \1 ♦ ���yy//��� \ //II I I IIIIIIIII — (�% 1 I' ��j III III /)11 JII 11 IIIIII IIII I\ _ I IIIIIIII I I i ✓i ';�� ;/ IIIIIIIIIIIII IIII III IIIIIIIIII IIIIIIIII I VIII// NOTES III II roo ,O/1. ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, II II \ \ \ STATE, AND NATIONAL REGULATORY STANDARDS AND ALL I/ //(( 'I 1 11 1 \\\\\ \ \ \ \\ ,✓0 ;✓� IIIIIIII \ ' 1 \ \ I I REQUIREMENTS IN THE PROJECT TECHNICAL SPECIFICATIONS. �II�111\W\\ \I \\V AA\ \�\�V1�'! V�1 ��V V II vvI1 \vvyy �� v v1 v \i A o ,✓ in v I I � ,tA � � \ o i r. � II \ \V A VAA 2. CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED IVAVAV� V A\ ����V� V 1 / I A N 1 ,i�GN/ IIIA IIA l I 1 ( \ GRADING LAND DISTURBANCE AND DRIVEWAY PERMITS HAVE BEEN \ \ \ \\ / / \✓,� III \ P, OBTAINED OBTAINED PRIOR TO BEGINNING CONSTRUCTION. 006 00 IIII I I I 3. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED �, �I/ v`„ VAA 0 IIII CONTRACTOR. �� // �A\VAA �► IIII '/i II v 77Acres � P t'1�11\\/�'r0 1.IIIIIIII / \/ 4. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE✓� EXACT LOCATION AND ELEVATION FOR ALL UTILITIES PRIOR TO I = A� \ 1 v 111\1\�1 '✓✓ CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY CONFLICTS OR \ �/ DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE00 NOT BEEN SHOWN ON THE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO 1 ` \ \\ \ \ )III\f/// // / II I CONSTRUCTION. 1 i� \\ 1 A I� �I iw 5. CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES CALLED 11 IIII II\ \ OUT TO REMAIN DURING CONSTRUCTION. ANY DAMAGE INCURREDDURING OR IS THE RESPONSIBILITY OF RESULTING FCONSTRUCTIONROM THECONTRACTORAND ACTIVITY BIEYREPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE 1 l \ \ I AGENCIES AT THE CONTRACTOR'S EXPENSE. 6. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE CONSTRUCTION ACTIVITY IS TO BEGIN. I THE CONTRACTOR SHALL NOTIFY ULOCO AT 1-800-632-4949 OR - Clayton - 811, 72 HOURS BEFORE CONSTRUCTION BEGINS. Deed Book 01E, Page 160 I PIN 7559-42-4323 7. EROSION CONTROL IS FIELD PERFORMANCE BASED AND CONTRACTOR SHALL INSTALL AND MAINTAIN ANY EROSION Pir. CONTROL MEASURES NECESSARY TO ASSURE MAXIMUM \ PROTECTION OF THE SITE DURING DEMOLITION AND CLEARING. 1 8. CONTRACTOR TO COORDINATE TIMING OF DEMOLITION AND CONSTRUCTION WITH OWNER TO ENSURE EXISTING FACILITIES REMAIN ACCESSIBLE. 9. ALL DEBRIS, STRUCTURES AND UTILITIES TO BE DEMOLISHED AND REMOVED FROM THE PROJECT SITE ARE NOT SHOWN ON THIS PLAN. ANY ADDITIONAL DEBRIS, STRUCTURES AND UTILITIES ENCOUNTERED DURING CONSTRUCTION, WHICH IN THE OPINION OF THE ENGINEER SHOULD BE DEMOLISHED AND REMOVED, SHALL BE DISPOSED OF OFF-SITE AT THE CONTRACTORS EXPENSE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY REQUIRED PERMITS. 1p ED Tract , 4.52 Acre: 0/_/ Deed Bo Page 26r 00 1437, Page 40 Deed Book 1437, Page 40 SS ed Book 2177, Page ee<Book 1968, Pag PIN 7559-42-454 PIN 7559-42-366 PIN 7559— PIN 7559 i EXISTING STORM WATER STRUCTURE TOP TO BE ADJUSTED TO BE FLUSH WITH PROPOSED PAVEMENT EXISTING STORM WATER PIPE AND STRUCTURE TO REMAIN (TYP) EXISTING 1 -STORY BLOCK STONE BUILDING TO BE REMOVED LOCATION OF EXISTING ONSITE TWSA SEWER LINE. TO BE REMOVED AND RELOCATED (CONTRACTOR TO FIELD VERIFY) (REFER TO C701 AND DETAILS) EXISTING DRIVEWAY CONNECTION TO BE REMOVED ALL EXISTING ASPHALT AND SITE FEATURES WITHIN EXISTING PROPERTY LINE TO BE REMOVED UNLESS OTHERWISE NOTED 50 N us 107 �o FypR/44 oq N a �q a SPv PNNPN R 0 SUBJECT PROPERTY O 06, VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA LU000—U) OWNER/DEVELOPER: WESTERN CAROLINA UNIVERSITY C14 C14 aNN Z 3476 OLD CULLOWHEE ROAD 0 J N N W CULLOWHEE, NORTH CAROLINA 28723 CONTACT: CURTIS MONTEITH W Z m LL (828) 227-7442 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. a 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 CONTACT: GREG HOFFMAN, P.E. (828) 252-5388 SURVEYOR. JOEL JOHNSON LAND SURVEYING, INC 701 SETTLEMENT ROAD SYLVA, NORTH CAROLINA 28779 CONTACT: R. JOEL JOHNSON, P.L.S. (828) 586-6488 PROJECT DATA PIN: 7559-42-4944, 7559-42-4744 PIN: 7559-42-4547, 7559-42-1855 ADDRESS: 128-227 ED NORTON RD 728 CENTRAL DRIVE DEED BOOK/PAGE: 2177/214,1437/403,1968/71,2053/269 SITE ACREAGE: 6.42 ACRES ZONING: COMMERCIAL PARKING CALCULATIONS: VEHICULAR SPACES: SPACES PROVIDED: 419 HANDICAPPED SPACES: SPACES REQUIRED: 9 SPACES PROVIDED: 9 IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.24 ACRES (4%) 6.18 ACRES (96%) POST -DEVELOPMENT: 3.37 ACRES (53%) 3.05 ACRES (47%) SOILS: BrC, CrD, EvE SOIL GROUP: B Know what's below. -MUE—ill 0111 before you dig. NORTH EXISTING CONDITIONS AND DEMOLITION PLAN GRAPHIC SCALE 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 200 WO Wc"o LU000—U) Z W L6 N W 04 F- W v L0 C14 C14 aNN Z N N (0 �V V `" 0 J N N W Z W N N W J S00 Q XQ J W W F_> W X W Z m LL co LL 00 0 m Cl) H O a Z Q a 33cli m U_j p J � U JJ Q ~ J m �_ m m m CO w ch o < m V) Ch Ch 0 0 N .. U. -Sm 0 U. a, 0 00 cfl 0 0 O O z J m z O J O w 0 0 z Q Cn z O 0 z O 0 U z X w C r6 00 T N U W N Z W U J N J W m U Z V z i Q z J O Q U O z w w O J J U I Cn w z Q z J O Q 0 z w W DRAWN BY:CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET C101 NOTES 1. ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL REGULATORY STANDARDS AND ALL REQUIREMENTS IN THE PROJECT TECHNICAL SPECIFICATIONS. 2. SINGLE-PHASE CONSTRUCTION. 3. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED CONTRACTOR. 4. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON THE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO CONSTRUCTION. 5. CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES (SHOWN TO REMAIN) AND NEWLY COMPLETED WORK DURING CONSTRUCTION. ANY DAMAGE INCURRED DURING OR RESULTING FROM CONSTRUCTION ACTIVITY IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE REPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT THE CONTRACTOR'S EXPENSE. 6. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY ULOCO AT 1-800-632-4949 OR 811, 72 HOURS BEFORE CONSTRUCTION BEGINS. 7. SIDEWALKS SHALL BE CONSTRUCTED IN ORDER TO PROVIDE POSITIVE DRAINAGE AWAY FROM ALL STRUCTURES. A MAXIMUM OF 5% SIDEWALK/CROSSWALK LONGITUDINAL SLOPE IS PERMITTED. A MAXIMUM OF 1/4" PER FOOT SIDEWALK/CROSSWALK CROSS SLOPE IS PERMITTED. ANY SIDEWALK/CROSSWALK INSTALLED WITH A STEEPER SLOPES SHALL BE REMOVED AND REPLACED AT CONTRACTORS EXPENSE. 8. ALL ROAD/PARKING LOT IMPROVEMENTS, STRIPING AND SIGNAGE SHALL BE IN ACCORDANCE WITH THE LATEST MANUAL ON UNIFORM TRAFFIC CONTROL DEVICE (MUTCD). CONTRACTOR MAY USE A PAINT SUITABLE FOR ASPHALT APPLICATION IN LIEU OF THERMOPLASTIC WITH PRIOR APPROVAL FROM THE ENGINEER. 9. CURB END TREATMENT TO BE APPLIED TO ALL CURB ENDS. REFER TO CURB END TREATMENT DETAIL. PROPOSED 9 - 8'x18' ADA PARKING SPACES (TYP) 1 - 8' WIDE VAN -ACCESSIBLE LOADING AISLE 4 - 5' WIDE LOADING AISLE 9 - PROPOSED HANDICAP PARKING SIGNS 9 - WHEEL STOPS 1 - STANDARD WHEELCHAIR RAMPS (TYP) (SEE DETAILS) NOTES: -HC SYMBOLS TO NOT BE STRIPED PROPOSED 2' WIDE CONCRETE FLUME EXISTING TROUT BUFFER (TYP) PROPOSED RETAINING WALL \ (DESIGN BY OTHERS) E JK -1-1, r�lyl - -9-43-1131 EXISTING PROPERTY LINE (TYP) PROPOSED CONCRETE SIDEWALK \ PRIG P i s� W DEPRESSED CURB AT EXISTING GRAVEL OH ROAD TO MATCH EXISTING GRADE I I I CONTRACTOR TO COORDINATE WITH UTILITY TO RELOCATE OVERHEAD WIRES AS REQUIRED DEPRESSED CURB AT EXISTING GRAVEL ROAD TO MATCH EXISTING GRADE I PROPOSED 2' WIDE , CONCRETE FLUME i II �° 24.0' W 00 000 (D LU W — N N Wz 00 N Nm Ln � F- 0000 V LO N CM 04 C4 0 a Z N N coZ 'T Z J W ONLU vO W J ONVD W w Z¢ Cn> W x 00 2 p LL W Q lL US Q0. mZ2 10 7 a z Q a F'1O _n �q! � R ryl aR m mo pR SPVPNNP� R O E ;UZ 0 V O N o Q �. �frC SUBJECT a v �\ PROPERTY . p c 0 11 0 P IV 210 ___ 'cn� PROPOSED SIDEWALK CONNECTION TO EXISTING �•> Gi O 3 EDGE OF PAVEMENT (CONTRACTOR TO MATCH 000 3 EXISTING ELEVATIONS) PIN 755° 1 O Deed Book b \ Deed Bor ----------------------- deed B, deed_B PIN - PIN X 0 )SED RETAINING WALL ;N BY OTHERS) PROPOSED BUS PULL OFF AND BUS STOP PROPOSED CONNECTION TO EXISTING ROAD (CONTRACTOR TO MATCH EXISTING ELEVATIONS) PROPOSED PARKING SPACE 9'X18' (TYP) PROPOSED 18" CURB AND GUTTER (TYP) PROPOSED 30" CURB AND GUTTER (TYP) PROPOSED ISLAND LANDSCAPING (TYP) PROPOSED CONNECTION TO EXISTING ROAD (CONTRACTOR TO MATCH EXISTING ELEVATIONS) PROPOSED STOP BARS (TYP) PROPOSED STOP SIGN (TYP) DEVELOPMENT DATA OWNER/DEVELOPER CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: PROJECT DATA VICINITY MAP (NOT TO SCALE) WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CURTIS MONTEITH (828) 227-7442 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 GREG HOFFMAN, P.E. (828) 252-5388 JOEL JOHNSON LAND SURVEYING, INC 701 SETTLEMENT ROAD SYLVA, NORTH CAROLINA 28779 R. JOEL JOHNSON, P.L.S. (828) 586-6488 PIN: 7559-42-4944, 7559-42-4744 PIN: 7559-42-4547, 7559-42-1855 ADDRESS: 128-227 ED NORTON RD 728 CENTRAL DRIVE DEED BOOK/PAGE: 2177/214,1437/403,1968/71,2053/269 SITE ACREAGE: 6.42 ACRES ZONING: COMMERCIAL DISTURBED AREA: 4.83 AC PARKING CALCULATIONS: VEHICULAR SPACES: SPACES PROVIDED: 419 HANDICAPPED SPACES: SPACES REQUIRED: 9 SPACES PROVIDED: 9 IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.24 ACRES (4%) 6.18 ACRES (96%) POST -DEVELOPMENT: 3.37 ACRES (53%) 3.05 ACRES (47%) SOILS: BrC, CrD, EvE SOIL GROUP: B Know what's below. 0111 before you dig. NORTH SITE PLAN GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 3: m 0- p J 0 0 J J H J m H m m Ofbi Uj 0 m � < Of o Of 0 o Cn 0 � 'If N o 00 c0 0 0 0 J 0)LLI LO boy °w � N Q o o �d � °GO 0111 II 0 z M� I..L 00 N i U W N Z W U_ J N J W m U Z z 0 0 Cn 0 a Q z J Wo' 0' 0 z w J 0 aJ M � I Zo' W w z UQ z J w 0 o Q z D 0 Q ♦ , z ElfLiU DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET T.TC% rT r 1. 2. 3. 4. PROPOS EXISTI� SEE GRADING, EROSION CONTROL, SHEETS FOR ALL GENERAL NOTES. FOR INCLUSION OF DETAILS SHEETS NO PORTION OF THIS PROJECT LIES FLOODPLAIN. SOIL TYPE B. RETAINING WALLS: ALL RETAINING WALL ELEVATIONS S TO FINISH GRADE ELEVATION. CONTI FOOTER/COVER OVER FOOTER. REFS FOOTER DESIGN. WALL DESIGN TO A PIPE PENETRATIONS PER PLANS. WALL DESIGN TO INCLUDE FOOTING 12" OF #57 WASHED STONE BEHIND WALL FROM BOTTOM TO TOP OF WALL. It ALL RETAINING WALLS PROVIDING A CHANGE OF GRADE OF 30" OR MORE SHALL BE PROTECTED WITH A GUARDRAIL. THE GUARDRAIL SHALL BE 42" MINIMUM IN HEIGHT, AND PREVENT THE PASSAGE OF A 21" SPHERE UNLESS ADJACENT TO A WALKING SURFACE. COORDINATE BARRIER STYLE AND COLOR WITH ARCHITECT AND ENGINEER. SEE SITE PLAN FOR APPROXIMATE LOCATION OF FENCING/BARRIERS. CONTRACTOR TO SUBMIT TO OWNER AND ENGINEER FOR REVIEW PRIOR TO ORDERING MATERIALS. CONTRACTOR TO COORDINATE WALL STYLE AND COLOR WITH ARCHITECT AND ENGINEER. CONTRACTOR RESPONSIBLE FOR OBTAINING BUILDING PERMIT FOR ALL RETAINING WALLS PRIOR TO ORDERING MATERIALS OR CONSTRUCTION. CONTRACTOR RESPONSIBLE FOR CONSTRUCTING RETAINING WALLS IN ACCORDANCE WITH ALL WALL MANUFACTURERS STANDARDS AND SPECIFICATIONS. ALL RETAINING WALLS 4' OR GREATER TO BE SUBMITTED TO JACKSON COUNTY BUILDING SAFETY DIVISION FOR REVIEW AND APPROVAL AND CERTIFIED BY THE WALL ENGINEER UPON COMPLETION. RETAINING WALLS SUBJECT TO ADDITIONAL LANDSCAPING DEPENDING ON HEIGHT AND MATERIAL. N us 107 �F ti Mpp�q< ; R OP o 0 � 5PN PNNPN R � � 2 o Q GCVO o . ............. . . . DEVELOPMENT DATA OWNER/DEVELOPER CONTACT: CIVIL ENGINEER: CONTACT: VICINITY MAP (NOT TO SCALE) WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CURTIS MONTEITH (828) 227-7442 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 GREG HOFFMAN, P.E. (828) 252-5388 SURVEYOR: JOEL JOHNSON LAND SURVEYING, INC 701 SETTLEMENT ROAD SYLVA, NORTH CAROLINA 28779 CONTACT: R. JOEL JOHNSON, P.L.S. (828) 586-6488 PROJECT DATA PIN: 7559-42-4944, 7559-42-4744 PIN: 7559-42-4547, 7559-42-1855 ADDRESS: 128-227 ED NORTON RD 728 CENTRAL DRIVE DEED BOOK/PAGE: 2177/214,1437/403,1968/71,2053/269 SITE ACREAGE: 6.42 ACRES ZONING: COMMERCIAL PARKING CALCULATIONS: VEHICULAR SPACES: SPACES PROVIDED: 419 HANDICAPPED SPACES: SPACES REQUIRED: 9 SPACES PROVIDED: 9 IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE—DEVELOPMENT: 0.24 ACRES (4%) 6.18 ACRES (96%) POST—DEVELOPMENT: 3.37 ACRES (53%) 3.05 ACRES (47%) SOILS: BrC, CrD, EvE SOIL GROUP: B T T'!'T'TTTI LIMITS OF DISTURBANCE STORM DRAINAGE PIPE SIL T FENCE EXISTING CONTOURS � m ■ m m m m m m SF W r 00 N z W O O O 0 Z 00 LU Ln Lo 00 7 0 a N N Z 1 Z W o0 oD00 Z Z a0 OJ W W LU LU W Jcc W W a w Z Q> w x co = O LL fn W O LL a M r a z a a� \o N LID 3: m a� p J 0 0 J J ~ J Q m m Cf) Of m w C Cn0 m o ry Cn 0 0 0 Of Of Cf) .. ..0 ... C) co c0 C 0 C11 a- c0 c0 0 0 0 P o0o Nb`y'%; _ _j 0) Q 0 U V) LL1 Lr) cn In N _ o� o ° d�d C�p� It 00 N i U LU U) z W U J J LU m U z R-1 z 0 w 0 0 w 0 GRAPHIC SCALE 50 0 25 50 100 200 ( IN FEET ) I inch = 50 ft. SHEET C301 100 00 A 0000 r ' 11 \o LU J 0 > U 1 W z w w \ J o v� *S /� \ �`� Q _j D j 0 o :is—�S— — Q J z Cn � o F LU w > � 03 0 U U z z / PROPOSED SILT FENCE z \ / (TYP) • © o 0 Li D Li U v V v z PROPOSED DIKE FOR STREAM BYPASS (TYP) cwn � Deed I Know what's below. \ Call before you dig. NORTH \ PROPOSED HEADWALL DRAWN BY: CLR (SEE DETAIL) CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 PHASE 1 EROSION CONTROL PLAN GRAPHIC SCALE 50 0 25 50 100 200 ( IN FEET ) I inch = 50 ft. SHEET C301 F'--_1 B - 11N 7559-43-3182 eel B-- 54\ Page PIN 75Sa-43-1131 / \ \\ \\\\ �V ^ 1 %t 3 I 1 1 \\ 617/ \\ \\\ \\\\1\\\\\\ � 1 1/ - V�\\\VA\\\�A�A\� \x \ I - �� a�l EXISTING PROPERTY LINE (TYP)— \ \ \WWoVIA\ V1 �� ��V A�v�VA11�V1 \\\ \\�\ oll v N � I / \\\\\ \ \ / / —�' NI 1 A\\V�11 wv v\ v �- �wV��AVA OH (I Carolina UniversityA ____2 I Deed Book 427, Page 399A�\\V�\� PIN 7559-23-1452 v � vv- �v ��\�\VA�lllllllll�llf v � 11 \ �1A V ■�\ 1 I IIII IIID \ � \IA11111 IIII IIII III � / I I 1VA\\ 111111 12��� ` II \ V \ \ I V I I �.�.- \�-� ��vv�vvvvvivviil�viiiv11'-- 11 Ih� 1 11 I vv v v `� v v vvvv ` �v v II � I il�, s I�pll�ll�l�lllj IIII Ijll IIIIIII� � I III IIII IIIA -- � I1V A \ V A � 1 v � � A I 1 II I IIII III 1 I�Illllllllljlllllllllllllllll/�� I IIIIIIIIIII1( \111\ \\\ \ \\ 11 \ � �\�� I I / III NII11 I1111111111I11 II , 1 111 1111 \\\\ \ \ ■ �\ I II NOTES 1. SEE GRADING, EROSION CONTROL, AND STORM DRAINAGE DETAIL SHEETS FOR ALL GENERAL NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL PLANS. 2. NO PORTION OF THIS PROJECT LIES WITHIN THE 100 -YR FEMA FLOODPLAIN. 3. SOIL TYPE B. 4. RETAINING WALLS: ALL RETAINING WALL ELEVATIONS SHOWN ARE FROM TOP OF WALL TO FINISH GRADE ELEVATION. CONTRACTOR TO ACCOUNT FOR FOOTER COVER OVER FOOTER. REFER TO WALL DESIGN FOR FOOTER DESIGN. WALL DESIGN TO ALSO ACCOMMODATE STORM PIPE PENETRATIONS PER PLANS. WALL DESIGN TO INCLUDE FOOTING DRAIN AND MINIMUM WIDTH OF 12" OF #57 WASHED STONE BEHIND WALL FROM BOTTOM TO TOP OF WALL. ALL RETAINING WALLS PROVIDING A CHANGE OF GRADE OF 30" OR MORE SHALL BE PROTECTED WITH A GUARDRAIL. THE GUARDRAIL SHALL BE 42" MINIMUM IN HEIGHT, AND PREVENT THE PASSAGE OF A 21" SPHERE UNLESS ADJACENT TO A WALKING SURFACE. COORDINATE BARRIER STYLE AND COLOR WITH ARCHITECT AND ENGINEER. SEE SITE PLAN FOR APPROXIMATE LOCATION OF FENCING/BARRIERS. CONTRACTOR TO SUBMIT TO OWNER AND ENGINEER FOR REVIEW PRIOR TO ORDERING MATERIALS. CONTRACTOR TO COORDINATE WALL STYLE AND COLOR WITH ARCHITECT AND ENGINEER. CONTRACTOR RESPONSIBLE FOR OBTAINING BUILDING PERMIT FOR ALL RETAINING WALLS PRIOR TO ORDERING MATERIALS OR CONSTRUCTION. CONTRACTOR RESPONSIBLE FOR CONSTRUCTING RETAINING WALLS IN ACCORDANCE WITH ALL WALL MANUFACTURERS STANDARDS AND SPECIFICATIONS. ALL RETAINING WALLS 4' OR GREATER TO BE SUBMITTED TO JACKSON COUNTY BUILDING SAFETY DIVISION FOR REVIEW AND APPROVAL AND CERTIFIED BY THE WALL ENGINEER UPON COMPLETION. RETAINING WALLS SUBJECT TO ADDITIONAL LANDSCAPING DEPENDING ON HEIGHT AND MATERIAL. \\\�A\VAA\��V AA\\\111111 IIII I 111111j1111 1I Q\\��\O�I1111�j�111�1111�111�1AII� � I ��I\Il�l�ll�ll�l�j � \\�0A\��A��Ill�lll�l�ll�lll��ljll� I I�IIII 11111 TD AVA\�� A A V 1 \ \ \ v■ / III / /I/� l IIII IIIII�III IIII IIII IIII IIII111111111111IIII I I �\VA\V A \ V A 1 A \ \ � 1111 // 11/� II IA i �O�L \\ 7,06-1 , ",.fin M�� —� I� • � �, W, 1\ o 1 SII I \ VAA\\\�vA\ V 1 I I I I II II Iv\vvv\`vvvvvvv� 1���' yi II yv 1 I �1� �I NII�II `� I 1 � 1 � � w � \\ � \ \\\ \VAA v v v `■\\ V I I III � I I I 223 ��/ ��� V A\\ v■ I I I I III Deed Baal.. PIN 23 I CIO 1 \1o i v � ao I B PIN 755 eed Book 13E, Page PIN 7559-42-1.-1 PIN 7559-42— PROPOSED TEMPORARY DITCH (TYP) / PROPOSED TEMPORARY SKIMMER BASIN 'A' Z 00 LO Lo DEPTH: 18" a N N LENGTH: 128' Z Z W o0 oD00 WIDTH: 64' OJ W W AREA: 8192 SF a w Z Q> VOLUME: 11451 CF ao=OLL 2:1 MAX. SIDE SLOPES (SEE DETAILS) a SKIMMER BASIN AND TEMPORARY DITCHES a SHALL MOVE AS GRADING PROGRESSES. CONTRACTOR SHALL MAINTAIN BASIN IN 1 LOW POINT OF PARKING LOT SURFACE. �\SKIMMER BASIN TO BE ABANDONED AND ,_T STORMWATER INFRASTRUCTURE IS INSTALLED \ WHEN DISTURBED SOIL COMPRISES LESS \ THAN ONE ACRE OF PARKING LOT SURFACE. _L 11 Q \ c • I Tract A 4.52 Acres �h Deed Book 2053, Page 269 Deed Book 1437, Page 403 Deed Book 1437, Page 403 SS ed Book 2177, Page 214 eedBook 1968, Page 71 PIN 7559-42-4547 PIN 7559-42-3668 PIN 7559-42-1855 PIN 7559-43-4025 PIN 7559-42-4944 PIN 7559-42-4744 0 0 x 0 IMITS OF DISTURBANCE (TYP) (TYP) EXISTING STORM DRAINAGE STRUCTURE EXISTING STORM DRAINAGE PIPE PROPOSED 60" CLASS V, RCP 50 N us 107 eFti Mpp7q< ; R o� V) O q P� PNNPN R 5 5 � 2 o Q GCVO OR ............. . DEVELOPMENT DATA OWNER/DEVELOPER CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: PROJECT DATA VICINITY MAP (NOT TO SCALE) WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CURTIS MONTEITH (828) 227-7442 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 GREG HOFFMAN, P.E. (828) 252-5388 JOEL JOHNSON LAND SURVEYING, INC 701 SETTLEMENT ROAD SYLVA, NORTH CAROLINA 28779 R. JOEL JOHNSON, P.L.S. (828) 586-6488 PIN: 7559-42-4944, 7559-42-4744 PIN: 7559-42-4547, 7559-42-1855 ADDRESS: 128-227 ED NORTON RD 728 CENTRAL DRIVE DEED BOOK/PAGE: 2177/214,1437/403,1968/71,2053/269 SITE ACREAGE: 6.42 ACRES ZONING: COMMERCIAL PARKING CALCULATIONS: VEHICULAR SPACES: SPACES PROVIDED: 419 HANDICAPPED SPACES: SPACES REQUIRED: 9 SPACES PROVIDED: 9 IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.24 ACRES (4%) 6.18 ACRES (96%) POST -DEVELOPMENT: 3.37 ACRES (53%) 3.05 ACRES (47%) SOILS: BrC, CrD, EvE SOIL GROUP: B LEGEND LIMITS OF DISTURBANCE STORM DRAINAGE PIPE SILT FENCE EXISTING CONTOURS PROPOSED CONTOURS ■■■■■N — SF SF — Know what's below. Call before you dig. NORTH PHASE 2 ROUGH GRADING & EROSION CONTROL PLAN GRAPHIC SCALE 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. W r 00 N z W O O OLr) Z 00 LO Lo W 7 Ln a N N Z Z W o0 oD00 Z� Z a0 OJ W W LU LU W Jcc W W a w Z Q> w x ao=OLL CO Z �WOLL a z r a a Q z 3� J 0Wo- N L0 00 T N U LU U) z W U J J W C0 U z J ~ m LLJ m � 0 J � m m D o J Q m Cf)O Q � O Z z o m w o Q 0 o o �INI�I I I ISI rj o� _j <0 - •- W U-) r4 N MN SHEET V Z Q a Q z J 0Wo- \ Q Ii O O w 11 Q z w z w J 0 J O 0 z U O z O z � Cn V) o 0� LU � Ld LL U z c� z < z J Q m O Ir Q c� v ♦ , z LL w cn v � � Q = cn w DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET NOTES 1. SEE GRADING, EROSION CONTROL, AND STORM DRAINAGE DETAIL SHEETS FOR ALL GENERAL NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL PLANS. 2. NO PORTION OF THIS PROJECT LIES WITHIN THE 100 -YR FEMA FLOODPLAIN. 3. SOIL TYPE B. 4. RETAINING WALLS: ALL RETAINING WALL ELEVATIONS SHOWN ARE FROM TOP OF WALL TO FINISH GRADE ELEVATION. CONTRACTOR TO ACCOUNT FOR FOOTER/COVER OVER FOOTER. REFER TO WALL DESIGN FOR FOOTER DESIGN. WALL DESIGN TO ALSO ACCOMMODATE STORM PIPE PENETRATIONS PER PLANS. WALL DESIGN TO INCLUDE FOOTING DRAIN AND MINIMUM WIDTH OF 12" OF #57 WASHED STONE BEHIND WALL FROM BOTTOM TO TOP OF WALL. ALL RETAINING WALLS PROVIDING A CHANGE OF GRADE OF 30" OR MORE SHALL BE PROTECTED WITH A GUARDRAIL. THE GUARDRAIL SHALL BE 42" MINIMUM IN HEIGHT, AND PREVENT THE PASSAGE OF A 21" SPHERE UNLESS ADJACENT TO A WALKING SURFACE. COORDINATE BARRIER STYLE AND COLOR WITH ARCHITECT AND ENGINEER. SEE SITE PLAN FOR APPROXIMATE LOCATION OF FENCING/BARRIERS. CONTRACTOR TO SUBMIT TO OWNER AND ENGINEER FOR REVIEW PRIOR TO ORDERING MATERIALS. CONTRACTOR TO COORDINATE WALL STYLE AND COLOR WITH ARCHITECT AND ENGINEER. CONTRACTOR RESPONSIBLE FOR OBTAINING BUILDING PERMIT FOR ALL RETAINING WALLS PRIOR TO ORDERING MATERIALS OR CONSTRUCTION. CONTRACTOR RESPONSIBLE FOR CONSTRUCTING RETAINING WALLS IN ACCORDANCE WITH ALL WALL MANUFACTURERS STANDARDS AND SPECIFICATIONS. ALL RETAINING WALLS 4' OR GREATER TO BE SUBMITTED TO JACKSON COUNTY BUILDING SAFETY DIVISION FOR REVIEW AND APPROVAL AND CERTIFIED BY THE WALL ENGINEER UPON COMPLETION. RETAINING WALLS SUBJECT TO ADDITIONAL LANDSCAPING DEPENDING ON HEIGHT AND MATERIAL. Know what's below. 0111 before you dig. PROPOSED 2' WIDE CONCRETE FLUME Western Carolina University - 2eed Book 712, Page 704 PROPOSED RIP RAP APRON 'B' - o� 1 � i i m I✓ EXISTING STORM DRAINAGE STRUCTURE TO BE ADJUSTED TO PROPOSED GRADES. GRATE TO BE REPLACED WITH MANHOLE LID LENGTH: 10' WIDTH AT FES: 30 WIDTH AT END: 12' I THICKNESS: 18"��r�� STONE CLASS: 2 (SEE DETAIL) ��� FG 18. D� FG 118,10'C 9.9 \ �V F 7.7 c 17.6 PROPOSED RIP RAP APRON A' y � LENGTH: 10' \ /17 3 /_, T WIDTH AT FES: 30 V ` \\ 2 2 G �FG7.8 B WIDTH AT END: 13' 6 1 1 Fc 7.1 Fc 17.4 PROPOSED STORMWATER PIPE (TYP) \\ - --- STONE - THICKNESS: 18" / � \ 1 � � Fc 7.0 �, STONE CLASS: 2 1 F 16.6 B2 B2 y o FG 16.9 PROPOSED STORMWATER STRUCTURE (SEE DETAIL) 1 0 '� : \ FC 1fY.8 = v (TYP) -� \ C1Bc 16 3s' 61 A 00 v� / PROPOSED STORM CROSSINGS A A C2 c 1 .5- v Is ALL 1, SIZE I I \ I I I I I � / l I I C 23. / C 22.8-- 2.8 - A2 -A3 ALL SLOPES GREATER THAN 4:1 (SEE PROFILES)(TYP) \ C 17.1��Y� X r K SHALL BE SEEDED WITH KENTUCKY \ S `\ \ \ C 16.6,,, 3 i 0 31. SLOPES 4:1 OR LESS SHALL BE N \ \ o A ' 1 B / / PROPOSED TROUT BUFFER TYP °DAW SEEDED WITH VELVA TURF (TYP) ( ) m \ Al v � / II � PROPOSED STORMFILTER � ` I A� '� ��' CARTRIDGE CHAMBER (TYP) D1 ll ofl,� V - - J -- I I °0 ��. ! II \\ ry�`� I \\ �. v , v/ - 15.5 2T-- _0 a� v \\\V A\ V � A � � � � �, �T�71 3 0 � � N T� 25 0 \\V�\ VA A V B 6 B W 10.9 �� - BC 24.5 - V A\\�` VAVA 00 �C C� � c �I� 1111 1II v j \ 1 -- - q BC 15 1 PERMANENT DIVERSION DITCH "B" BOTTOM WIDTH: 0' SIDE SLOPE: 2:1 ����\ III / �� \ �\ B5 - B4 \ DEPTH: 1' - A\VAvv III I //� / �_ �i� III 4.A l �IBWW14.7 SLOPE: 1% MIN CHANNEL LINER: SC250 11 IIII IIIIIIIIIIIIIIII I\ _ (SEE DETAIL) �� lel II I I\ 111 I 121 1 I1 \VA V V V / y\�I IIII o _ v a I N�NN I ljl�\� IIAI VI 1 n 1 A V �A3 I Illc�� \ S IV PERMANENT DIVERSION DITCH "A" A \ VA � 0' N BOTTOM WIDTH: L / / I I�IIII A �j111 III IIII II IIII N N 7, (7 N N I \ \ \ III III SIDE SLOPE: 2:1 IIIII11111\III�11�11111� IIIIIIIII I 111 1 .2 DEPTH: 1' l I i \ I IIII SLOPE: 1% MIN\\ �\ \V11I\1 I\11) 1111 / II 1 IIII V AA A CHANNEL LINER: SC250 \\\\\\\\ \\\\\\\\\\\\\Illlllllll I 11111j11j1 1 111111 I \\VA\��1�1111111111111111�1111� 11111111j1111 \11111 I I \ \ \ V 1 \ I /)\V / I I IIII III II v ��� (SEE DETAIL) III�II IIII I I IIII I V A 1 \ I 1 \ \ I l I I I I \ I I \ I �\\�OAlll\111 ,'1111AII�III�III� �J���! I II�IIII 11111 A\\\\\V�\ III 111 IIIIIIII IIII III VIII ALL 2:1 SLOPES AND GREATER TO BE IIIIIIIIjjPlllllllllllllllllllll I l I I IIIIIIIIIII \ _\\\ \ \ \\ \\ \ \ L�• / ///�l/ / / l l llllll 11111 ���� . / v.. STABILIZED WITH NORTH AMERICAN Illllliilllllllllllllll IIII 11111j1 I / 1 111111 1111 I \\ 11 \ \ \ \ \ 1 / ///// / 111 l/ lll�'ll ec 28 .' ' Ill/ III lil IIII IIII IIII I / TC 19. i II I I \ II 11 \ \ \ 1 ( / f l / / / // I / I Illlull \ , ( ) I GREEN S150 OR APPROVED EQUIVALENT IIII III \ li I III IIII (IIIIIIII BC 18.9 I 11111111111111111 I II / i � �Illllll11�11111�11111111'llllll l / / / 111 11111 I\\�\\ ped Book 1176, Page 746 IIII IIII 1 II�IIII�J II / r 2� III �11 11111 VA A PIN 7559-31-8461 �IIIII III Illi I II Illy � l I I B 2 %1\111 11 1 � VA It Ill/ II IIIIIIII IIII II IIIII�ll11� % IIA 1\ IIII \ \\ V A A \ A V �/ III i�TC 30.5 /%111111 IIII 11�I111lllll BC 30. ///IIIIIIIIIII 1111111 Illlllllllllj� 1111 �- I 'I \ � \\ \ \ I II l I I IIII IIII I I I ////JII III IIIIIIIIIII llllll` /1 1 1I 222 \ II (IIIIIIIIIII /// ////// / I I/1111/IIIIIIIl111 // 11111 \ 221 2� IIII I \ \ IIII \III \ \ III IIII IIII 1 \ \ IIII II II111\I\\\\\\ \\ \ 1 / �/ 1\\�\ \\\\I I\ I II� \\IIII 1111\\� vv\�� ��A�VA \ VAA\�\V1 1 \ Y ✓� \ I �vvvvv 1 \ \I (IIII II �ti V \ �1 V \V /V TC 4 A 1 Al VA IIII II II/ B 24.0 Tract B S _ $I ZZ�J 1.77 Acres \ TC 26.1 IIII 1 ,ea Book 2053, Pac- �\ V A� I BC 25.6 I IIII 1111 III \ t1 PROPOS2' WIDE II I gw3 1' �\ 1 \V.I v jy , 1 T \ \ CONCRETE FLUMEED �1\�. aw 2 G - -� r4.3 221_��. 5. A 221 ----- 9 NORTH PROPOSED SEWER CROSSING 2 0 (SEE PROFILES)(TYP) \ 1 \ - - ----- q1 i oo N i I ISI I ool N PROPOSED CONNECTION TO EXISTING CURB SYSTEM (CONTRACTOR TO MATCH EXISTING ELEVATIONS) PROPOSED CONNECTION TO CENTRAL DRIVE (CONTRACTOR TO MATCH EXISTING ELEVATIONS) PROPOSED "131" TIE-IN TO STORMWATER STORAGE PIPE (SEE DETAILS) PROPOSED 281 LF OF 96" STORMWATER STORAGE PIPE EXISTING STORMWATER STRUCTURE INV.: 2222.97' RIM TO BE ADJUSTED TO PROPOSED GRADE PROPOSED STORMFILTER OUTLET CHAMBER "A4" (SEE DETAIL) II • I b Ib - y PROPOSED CONNECTION TO CENTRAL DRIVE (CONTRACTOR TO MATCH EXISTING ELEVATIONS) ALL SLOPES GREATER THAN 3:1 BE HYDROSEEDED WITHIN 7 DAYS OF ESTABLISHED FINISH GRADE FOR STABILIZATION. PERMANENT VEGETATION SEED TO CONFORM WITH SEEDING REQUIREMENTS SHOWN ON DETAIL SHEET (APPROVED BY OWNER). \ PROPOSED PERMANENT 60' CULVERT WITH HEADWALL (REFER TO DETAILS) PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL Al -A2 30" 107' 13.2% HDPE A2 -A3 30" 15' 1.0% HDPE A3 -A4 30" 1' 1.0% HDPE 131-132 30" 3' Tract A HDPE 132-133 - 21' 4.52 Acres HDPE 133-134 24" Oy Deed Book 2053, Page 2, HDPE 134-135 24" 98' \Deed Book 1437, Page 403 Deed Book 1437, Page 403 HDPE 135-136 24" 87' lj�qed Book 2177, Page 214 HDPE 136-137 18" 29' ee�Book 1968, Page 7 HDPE C1-C2 24" 16' PIN 7559-42-4547 HDPE 1 60" 419' PIN 7559-42-3668 CLASS V RCP z PIN 7559-42-1855 J O 0 z B3 10+34 PIN 7559-43-4025 9.2'± 4' ROUND GRATE INLET Q m ♦ , PIN 7559-42-4944 0 w v w ~ z L, -559 PROPOSED CONNECTION TO CENTRAL DRIVE (CONTRACTOR TO MATCH EXISTING ELEVATIONS) ALL SLOPES GREATER THAN 3:1 BE HYDROSEEDED WITHIN 7 DAYS OF ESTABLISHED FINISH GRADE FOR STABILIZATION. PERMANENT VEGETATION SEED TO CONFORM WITH SEEDING REQUIREMENTS SHOWN ON DETAIL SHEET (APPROVED BY OWNER). \ PROPOSED PERMANENT 60' CULVERT WITH HEADWALL (REFER TO DETAILS) PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL Al -A2 30" 107' 13.2% HDPE A2 -A3 30" 15' 1.0% HDPE A3 -A4 30" 1' 1.0% HDPE 131-132 30" 3' 1.0% HDPE 132-133 30" 21' 1.0% HDPE 133-134 24" 127' 1.0% HDPE 134-135 24" 98' 1.0% HDPE 135-136 24" 87' 1.0% HDPE 136-137 18" 29' 1.0% HDPE C1-C2 24" 16' 7.7% HDPE 1 60" 419' 3.1% CLASS V RCP N us 107 pFti �O F,ypRiq� o� N a o E SPON PNNPN R r �p 0 SUBJECT PROPERTY O1 .............. DEVELOPMENT DATA OWNER/DEVELOPER CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: PROJECT DATA VICINITY MAP (NOT TO SCALE) WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CURTIS MONTEITH (828) 227-7442 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NORTH CAROLINA 28801 GREG HOFFMAN, P.E. (828) 252-5388 JOEL JOHNSON LAND SURVEYING, INC 701 SETTLEMENT ROAD SYLVA, NORTH CAROLINA 28779 I JOEL JOHNSON, P.L.S. (828) 586-6488 PIN: 7559-42-4944, 7559-42-4744 PIN: 7559-42-4547, 7559-42-1855 ADDRESS: 128-227 ED NORTON RD 728 CENTRAL DRIVE DEED BOOK/PAGE: 2177/214,1437/403,1968/71,2053/269 SITE ACREAGE: 6.42 ACRES ZONING: COMMERCIAL DISTURBED AREA: 4.83 AC PARKING CALCULATIONS: VEHICULAR SPACES: SPACES PROVIDED: 419 HANDICAPPED SPACES: SPACES REQUIRED: 9 SPACES PROVIDED: 9 IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.24 ACRES (4%) 6.18 ACRES (96%) POST -DEVELOPMENT: 3.37 ACRES (53%) 3.05 ACRES (47%) SOILS: BrC, CrD, EvE SOIL GROUP: B STRUCTURE TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DEPTH DESCRIPTION INV. IN 2186.8 (D1 -D2) HEADWALL RIM 2195.2 14+24 INV. OUT 2199.8 (D1 -D2) Al 10+00 INV. IN 2192.4 (A1 -A2) 3.7'± FLARED END SECTION Q z RIM 2219.2 J Df Df LO A2 11+10 INV. IN 2206.5 (A2 -A3) 12.6'± 4' ROUND JUNCTION BOX INV. OUT 2206.5 (A1 -A2) z Ow RIM 2219.9 w _ A3 11+29 INV. IN 2206.7 (A3 -A4) 13.2'± 4' ROUND JUNCTION BOX a_ w w INV. OUT 2206.7 (A2 -A3) 0 Q� � z RIM 2217.0 � Q Of B2 10+07 INV. IN 2206.7 (132-133) 10.2'± 6' ROUND JUNCTION BOX mz o UQ INV. OUT 2206.7 (131-132) U) z RIM 2216.2 J O 0 z B3 10+34 INV. IN 2207.4 (133-134) 9.2'± 4' ROUND GRATE INLET Q m ♦ , INV. OUT 2206.9 (132-133) 0 w v w ~ z L, RIM 2218.4 w 3�: DRAWN BY: B4 11+64 INV. IN 2208.7 (64-65) 9,7'± 4' ROUND JUNCTION BOX 17-17656-01 INV. OUT 2208.7 (133-134) RIM 2216.7 B5 12+65 INV. IN 2209.7 (65-136) 7.0'± CURB INLET INV. OUT 2209.7 (B4-135) RIM 2214.6 B6 13+55 INV. IN 2211.3 (136-137) 4.1'± 4' ROUND CURB INLET INV. OUT 2210.5 (135-136) RIM 2215.4 B7 13+88 INV. OUT 2211.6 (136-137) 3.8'± CURB INLET RIM 2205.5 C2 10+19 INV. IN 2197.9 (EX. PIPE 1) 7.6'± 4' ROUND JUNCTION BOX INV. OUT 2197.9 (C1-C2) INLET/OUTLET TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DESCRIPTION 1 10+00 INV. IN 2186.8 (D1 -D2) HEADWALL 1 14+24 INV. OUT 2199.8 (D1 -D2) HEADWALL FINE GRADING & STORM DRAINAGE PLAN GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. WO p00 00 LO 00 N O W- N a WLO� W N N a Z N N to 0 LO 7 Z 0 J N N W W N N J W W W W 00 J H> W x CL W Z ao=OLL (OQa W OLL Zaa a Q z W J Df Df LO E 0 U Q y a a Q C .. o N U CL i _0a 20 '> Z 4) 0 3 VOV 3 m m p J O 0 J J Q J Q m Q z mm m m Cn L af Q m Cn O O0 O 0 00 C0 0 0 0 I c� l r,6 co T N U W N z W U J m J W m U Z E z O m C) U) 0 i® SHEET 200 C401 V Z Me I..L Q a Q z W J Df Df Q O C_ 0 z Ow w _ j z Q_j_j O a_ w w U v 0 Q� � z � Q Of U) w o LU Ld mz o UQ U) z ' J O 0 z 0 0 Q m ♦ , z w 0 w v w ~ z L, w 3�: DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET 200 C401 SHALLOW TYPE (5 FEET OR LESS IN DEPTH) 6" MIN 6" MIN MIN. 6" WASHED STONE BEDDING NOTES: 36" SEE NOTE 'A' Ln p w w 26" X w 0 O0 z NOTE 'A' FOR CURB INLET: FOR GRATE INLET: FOR JUNCTION BOX: FOR CONVEX INLET: INTERMEDIATE TYPE (4'X4') (5 FEET TO 20 FEET IN DEPTH) STANDARD STANDARD REINFORCED STEPS 16" STEPS 16" ON CONCRETE SLAB ON CENTER CENTER 36" 6" MIN. 48" MIN. 6" WASHED STONE BEDDING MIN. 6" WASHED STONE BEDDING MIN. 6" W, STONE BE__-_ FRAME, GRATE & HOOD PER D.O.T. STD. 840.03E FRAME, GRATE & HOOD PER D.O.T. STD. 840.16 FRAME & COVER PER D.O.T. STD. 840.54 FRAME, GRATE & HOOD PER NEENAH CONVEX INLET GRATE R-2577 60" 1. CONCRETE SHALL BE 4000 PSI MIN. FOR ALL PRECAST CONCRETE CATCH BASINS. 2. PRECAST CONCRETE STRUCTURES MAY ONLY BE INSTALLED TO DEPTHS CERTIFIED AS ACCEPTABLE BY THE o MANUFACTURER. 36" 3. "WAFFLE" BOXES ARE ACCEPTABLE FOR SHALLOW TYPE CATCH BASINS. 4. PRECAST CONCRETE CATCH BASINS SHALL CONFORM TO `\j NCDOT STD. 840.02. SLAB DETAIL INCOMING PIPE FLARED END SECTION MATERIAL TO MATCH MATERIAL OF INCOMING PIPE C�7 6 SLAB THICKNESS AND REINFORCEMENT FOR SOIL AND TRAFFIC LOADING BY AN ENGINEER PRECAST CONCRETE CATCH BASIN DETAILS FOR GRATE INLETS, CURB INLETS, AND JUNCTION BOXES NOT TO SCALE 3'- 0" 6„ 2'- 0" 6„ TOOLED EDGE (TYP) FINISH GRADE FINISH GRADE 3" RADIUS (TYP) 4000 PSI III CONCRETE _ 6" ��111=6„ 01� b a 6" MIN. MIN. COMPACTED ABC COMPACTED SUBGRADE CONCRETE FLUME DETAIL PLAN ELEVATION NOTES: 1. THE DIMENSION OF THE THE FLARED END SECTION SHALL BE PER MANUFACTURER'S SPECIFICATIONS. 2. THE SKIRT SECTION OF THE FLARED END SECTION SHOULD BE JOINED TO THE INCOMING PIPE PER MANUFACTURER'S SPECIFICATIONS. NOT TO SCALE PIPE OUTLET TO FLAT AREA NO WELL-DEFINED CHANNEL PLAN CONSTRUCTION SEQUENCE: 1. NOTIFY NCDEQ ASHEVILLE REGIONAL OFFICE LAND QUALITY INSPECTOR PRIOR TO ANY LAND DISTURBANCE 2. INSTALL SITE CONSTRUCTION ENTRANCE, STONE STAGING, AND MOBILIZATION AREA. 3. INSTALL ALL EROSION CONTROL MEASURES AS REQUIRED BY NCDEQ -INSTALL SILT FENCE FIRST, THEN STREAM CROSSING -FOLLOWING INSTALLATION OF INDICATED STORM DRAINAGE STRUCTURES, INSTALLATION OF SEDIMENT TRAPS, BARRIERS AND DIVERSION DITCHES CAN COMMENCE AS NEEDED. 4. INSTALL STREAM CROSSING AND SEWER BYPASS. ALL WORK IN THE STREAM BED SHALL BE PERFORMED IN THE DRY. 5. PROCEED WITH GRADING, CLEARING AND GRUBBING. 6. CONSTRUCT REMAINDER OF PROPOSED PARKING LOT AND STORM DRAINAGE. 7. APPLY TEMPORARY AND PERMANENT SEEDING RIP RAP AND STABILIZATION MEASURES. 8. NOTIFY NCDEQ ASHEVILLE REGIONAL OFFICE LAND QUALITY INSPECTOR OF POST STABILIZATION AND PROVISIONS FOR THE REMOVAL OF ALL EROSION, SEDIMENT CONTROL DEVICES UPON APPROVAL FROM TH ASHEVILLE REGIONAL OFFICE LAND QUALITY INSPECTOR MAINTENANCE INSPECTIONS SHALL BE PERFORMED WEEKLY AND AFTER EACH RAINFALL. ALL REPAIRS NECESSARY SHOULD BE MADE IMMEDIATELY AND IN STRICT ACCORDANCE WITH NCDEQ STANDARDS AND NPDES PERMIT. NCDEQ EROSION CONTROL NOTES GENERAL: ALL EROSION CONTROL MEASURES ARE TO BE PERFORMED IN STRICT ACCORDANCE WITH REQUIREMENTS OF NCDENR. THE FOLLOWING CONSTRUCTION SEQUENCE SHALL BE COMPLIED WITH FOR ALL WORK. 1. OBTAIN PROVISIONAL PERMIT. 2. INSTALL ALL EROSION CONTROL MEASURES AS REQUIRED. 3. OBTAIN GRADING PERMIT THROUGH ON-SITE INSPECTION BY A REPRESENTATIVE OF NCDEQ. 4. PROCEED WITH GRADING, CLEARING, AND GRUBBING. 5. SEED AND MULCH DENUDED AREA WITHIN EITHER 7 CALENDAR DAYS (SLOPES GREATER THAN 3:1) OR 14 CALENDAR DAYS (3:1 OR FLATTER). AFTER FINISHED GRADE ARE ESTABLISHED, TEMPORARY SEEDING AND SOIL AMENDMENTS SHALL BE PLACED ON A PREPARED SEEDBED AT THE FOLLOWING RATES PER ACRE. LIME 2,000 LBS FERTILIZER (10-10-10) 1,000 LBS STRAW MULCH 4,000 LBS FOR LATE WINTER/EARLY SPRING SEEDING ADD TO THE ABOVE: RYE GRAIN 120 LBS ANNUAL LESPEDEZA 50 LBS (OMIT IF COVER IS NOT TO EXTEND BEYOND JUNE) FOR SUMMER SEEDING ADD: GERMAN MILLET 40 LBS FOR FALL ADD: RYE GRAIN 120 LBS IF HYDROSEEDING IS USED, WOOD CELLULOSE MAY BE SUBSTITUTED FOR STRAW MULCH AT THE RATE OF 1,000 LBS PER ACRE. 6. MAINTAIN SOIL EROSION CONTROL MEASURES UNTIL PERMANENT GROUND COVER IS ESTABLISHED. 7. REMOVE SOIL EROSION CONTROL MEASURES AND STABILIZE THESE AREA. 8. REQUEST FINAL APPROVAL BY NCDEQ. PIPE OUTLET TO WELL-DEFINED CHANNEL PLAN La La o 000�0000��01 FILTER BLANKET FILTER BLANKET SECTION AA SECTION AA NOTES: 1. La IS THE LENGTH OF THE RIP RAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (MINIMUM IS 24" DEEP IF STONE IS CLASS II) 3. IN A WELL-DEFINED CHANNEL, EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. 4. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIP RAP AND SOIL FOUNDATION. 5. COMPACT ANY REQUIRED FILL TO DENSITY OF SURROUNDING UNDISTURBED MATERIAL. 6. RIP RAP MAY BE FIELDSTONE OR ROUGH QUARRY STONE AND SHALL BE HARD. ANGULAR AND WELL -GRADED. 7. CONSTRUCT APRON AT ZERO GRADE. TOP OF RIP RAP SHALL BE LEVEL WITH THE RECEIVING CHANNEL OR SLIGHTLY LOWER. 8. ALIGN APRON WITH RECEIVING CHANNEL OR STREAM. ASSURE APRON IS STRAIGHT THROUGHOUT ITS LENGTH. 9. END WIDTH OF APRON TO BE EQUAL TO WIDTH OF RECEIVING CHANNEL. FLARED END SECTION WITH RIP -RAP APRON NOT TO SCALE NOTE: DITCH SLOPE TO BE AT A 1% MIN SLOPE FROM INLET TO OUTLET PERMANENT DRAINAGE DITCH NOT TO SCALE PERMANENT SEEDING MEASURES GENERAL CONSTRUCTION NOTES ALL PERMANENT MEASURES ARE TO BE PERFORMED IN STRICT ACCORDANCE WITH REQUIREMENTS OF NCDEQ. 1. ALL GRADING, STORM INSTALLATION, AND SOIL EROSION CONTROL MEASURES ON THIS SITE THE FOLLOWING APPLY TO AREAS WITHIN NCDENR PERMANENT SEEDING MIXTURE AREA #1M: TIME FRAME MUST BE AUTHORIZED BY PERMITS ISSUED BY NCDEQ. ALL SITEWORK SHALL BE IN PERIMETER DIKES, SWALES, 7 DAYS ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL REGULATORY STANDARDS AND ALL SEEDING MIXTURE: CONCRETE SHALL BE CLASS A OR B, 4000 PSI MINIMUM, MEETING THE REQUIREMENTS OF REQUIREMENTS IN THE PROJECT TECHNICAL SPECIFICATIONS. SPECIES RATE (LB/ACRE) 2. CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED GRADING, EROSION CONTROL, SLOPES GREATER THAN 3:1 7 DAYS STORM WATER, LAND DISTURBANCE, AND ASSOCIATED NON -GRADING PERMITS HAVE BEEN TALL FESCUE 100 3 OBTAINED PRIOR TO BEGINNING CONSTRUCTION. PANICUM VIRGATUM 10 AND/OR 834. NOT STEEPER THAN 2:1, REDTOP 5 3. ALL CONSTRUCTION SHALL BE UNDER THE INSPECTION OF THE ENGINEER, THE OWNER, KENTUCKY BLUEGRASS 5 14 DAYS NCDEQ. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 72 HOURS PRIOR TO BEGINNING TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED SOILS 0 WORK. ANY WORK COVERED PRIOR TO ENGINEER'S INSPECTION IS SUBJECT TO UNCOVERING NURSE PLANTS: 14 DAYS AND BACKFILLING AT THE CONTRACTOR'S EXPENSE. BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO 16. PERIMETERS AND MAY 1 OR AFTER AUG. 15, ADD 40 LB/ACRE RYE (GRAIN). IT MAY BE BENEFICIAL TO PLANT THE GRASSES IN 4. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED CONTRACTOR. LATE SUMMER. cn STORM DRAINS AND STREAMS UNLESS NO REASONABLE Li 5. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND SEEDING DATES: ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY BEST POSSIBLE CONCRETE MATERIALS MUST BE CONTROLLED TO AVOID CONTACT CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON THE PLANS BELOW 2500 FT: AUG. 15 - SEPT. 1 JULY 25 - SEPT 15 FOR PREPARATION OF FINAL RECORD DRAWINGS. AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO MAR. 1 - APR. 1 MAR. 1 - MAY 10 17. CONSTRUCTION. ABOVE 2500 FT: JULY 25 - AUG. 15 JULY 15 - AUG. 30 DISCHARGES ,TO FEDERALLY -LISTED WATERS MAR. 20 - APR. 20 MAR. 5 - MAY 15 6. PROTECT EXISTING SITE FEATURES (SHOWN TO REMAIN) AND NEWLY COMPLETED WORK 18. CONTRACTOR IS REQUIRED TO OBTAIN AND PROVIDE A COPY OF THE EROSION CONTROL DURING CONSTRUCTION. ANY DAMAGE INCURRED DURING OR RESULTING FROM COMPLETE SEEDING EARLIER IN FALL, AND START LATER IN SPRING ON NORTH- AND EAST -FACING CONSTRUCTION ACTIVITY IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE SLOPES. THE DIRECTOR OF DWQ DETERMINES THAT OTHER BMPS PROVIDE REPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES, AS PERMIT TO NCDEQ INSPECTOR PRIOR TO CONSTRUCTION. WELL AS THE PROJECT PLANS AND SPECIFICATIONS, AT THE CONTRACTOR'S EXPENSE. SOIL AMENDMENTS: APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL 7. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE LIMESTONE AND 1,000 LB/ACRE 5-10-10 FERTILIZER. CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY NC ONE CALL AT MUST BE SECURED FOR THE BORROW OR WASTE MATERIAL SITE PRIOR TO INITIATION OF 4) 811, 48 HOURS BEFORE CONSTRUCTION BEGINS. NOTIFY THE ENGINEER AT LEAST 72 MULCH: ANY LAND DISTURBING ACTIVITY HOURS BEFORE STARTING CONSTRUCTION ACTIVITIES. APPLY 4,000-5,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING 20. ALL FILL SLOPES SHALL BE COMPACTED FULL DEPTH TO NOT LESS THAN 95% MAXIMUM MATERIAL. ANCHOR MULCH BY TACKING WITH ASPHALT, ROVING, OR NETTING. NETTING IS THE PREFERRED 8 EROSION CONTROL IS A FIELD PERFORMANCE BASED ACTIVITY; AND ADDITIONAL SILTFENCES, ANCHORING METHOD ON STEEP SLOPES. • TEMPORARY SEDIMENT BASINS, AND ALL OTHER MEASURES MAY NEED TO BE AND DEBRIS, AND BE PROPERLY BENCHED AND DRAINED. ADDED IN ADDITION TO THE APPROVED PLAN AS NECESSARY. MEASURES SHOWN CAN AND MAINTENANCE: SHOULD BE ADJUSTED TO ASSURE MAXIMUM PROTECTION ON SITE. CONTRACTOR SHALL MOW NO MORE THAN ONCE A YEAR. REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. RECORDS MUST BE KEPT FOR 3 YEARS AND AVAILABLE ON-SITE ADD ADDITIONAL MEASURES AS NEEDED IN ENVIRONMENTALLY SENSITIVE AREAS. RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. DURING BUSINESS HOURS UNLESS A SITE-SPECIFIC EXEMPTION IS 9. CONTRACTOR IS RESPONSIBLE FOR INSTALLING, MAINTAINING, AND REMOVING ALL APPROVED. NECESSARY EROSION AND SEDIMENTATION CONTROL MEASURES. I) GROUND STABILIZATION 10. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ADJUSTMENT OF ALL UTILITY SURFACE ACCESSES WHETHER THE CONTRACTOR PERFORMS THE WORK OR A SITE AREA DESCRIPTION STABILIZATION STABILIZATION TIME CONCRETE AND MASONRY SHALL MEET THE REQUIREMENTS OF APPROPRIATE SECTION OF TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, 7 DAYS NONE DITCHES, AND SLOPES CONCRETE SHALL BE CLASS A OR B, 4000 PSI MINIMUM, MEETING THE REQUIREMENTS OF co W HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES GREATER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR THE REQUIREMENTS OF SECTION 940, CONSTRUCTED IN ACCORDANCE WITH SECTION 830 3 LESS IN LENGTH AND ARE N AND/OR 834. NOT STEEPER THAN 2:1, NO PAINT OR LIQUID IN STREAM OR STORM DRAINS. J J 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 -DAYS FOR SLOPES TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED SOILS 0 GREATER THAT 50' IN LENGTH ALL OTHER AREAS WITH 14 DAYS NONE (EXCEPT FOR SLOPES FLATTER THAN 4:1 16. PERIMETERS AND • EARTHEN -MATERIAL STOCKPILES MUST BE LOCATED 50' FROM HQW ZONES) UTILITY COMPANY PERFORMS THE WORK. 11. ALL AREAS WHERE THERE IS EXPOSED DIRT SHALL BE SEEDED, FERTILIZED AND MULCHED ACCORDING TO THE SPECIFICATIONS NOTES IN THE PLANS. SITE STABILIZATION IS A PERFORMANCE BASED REQUIREMENT, AND THE SITE WILL NOT BE ACCEPTED UNTIL PERMANENT VEGETATION IS ESTABLISHED TO THE SATISFACTION OF THE ENGINEER. 12. ALL HIGH DENSITY POLYETHYLENE (HDPE) CORRUGATED STORM SEWER DETENTION PIPE SHALL BE TYPE "S" HANCOR SURELOK ADSN12 OR APPROVED EQUIVALENT WITH WATER TIGHT JOINTS MEETING AASHTO M252, M294 OR MP7. ALL HDPE PIPE IS TO BE INSTALLED ACCORDINGLY TO MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH ASTM D2321 WITH THE EXCEPTION THAT MINIMUM COVER IN TRAFFIC LOAD AREA SHALL BE 24" FOR 4"-48" AND 18" FOR 60". PIPE MATERIAL SHALL MEET THE PRODUCT SPECIFICATIONS OF ASTM F667 AND SHALL HAVE A SMOOTH WALL INTERIOR. FOR ALL STORM SYSTEMS, WORK MUST BEGIN AT THE LOW POINT OF THE SYSTEMS. NOTIFY THE ENGINEER IMMEDIATELY OF ANY VARIANCES FROM EXPECTED CONDITIONS. 13. CURB INLET FRAME, GRATE AND HOOD SHALL CONFORM TO NCDOT 840.03E. DROP INLET FRAME AND GRATE SHALL CONFORM TO NCDOT 840.16. FIELD INLET COVER SHALL CONFORM TO NCDOT STANDARD DETAIL 840.03, OPENING FACING UPSTREAM. MANHOLE RING AND LID TO CONFORM TO NCDOT 840.54. OPEN THROAT INLETS TO CONFORM TO NCDOT 840.04 WITH A MANHOLE RING AND LID INSTALLED IN THE TOP FOR ACCESS TO THE STRUCTURE. SET ACCESS POINT ADJACENT TO A STRUCTURE WALL AS TO ALLOW ACCESS TO STEPS. *EXTENSIONS OF TIME MAY BE APPROVED BY THE PERM TTING AUTHORITY BASED ON 14. CONCRETE AND MASONRY SHALL MEET THE REQUIREMENTS OF APPROPRIATE SECTION OF WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT M KE COMPLIANCE IMPRACTICABLE. 0 J N N NCDOT STANDARD SPECIFICATIONS FOR ROAD AND STRUCTURES (LATEST EDITION). (SECTION II.B(2)(B)) W J W W F-> W x CONCRETE SHALL BE CLASS A OR B, 4000 PSI MINIMUM, MEETING THE REQUIREMENTS OF co W COm0U. m OLL SECTION 900, CONSTRUCTED IN ACCORDANCE WITH SECTION 825. MASONRY SHALL MEET 2) BUILDING WASTE HANDLING ¢3 THE REQUIREMENTS OF SECTION 940, CONSTRUCTED IN ACCORDANCE WITH SECTION 830 3 N AND/OR 834. • NO PAINT OR LIQUID IN STREAM OR STORM DRAINS. J J M L.L • DEDICATED AREAS FORR DEMOLITION, CONSTRUCTION AND OTHER 15. TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED SOILS 0 WASTES MUST BE LOCATED 50' FROM STORM DRAINS AND % LABORATORY UNDER ALL PAVED AREAS. Z STREAMS UNLESS NO REASONABLE ALTERNATIVES AVAILABLE. 16. CONTRACTOR RESPONSIBLE FOR KEEPING ACCURATE LOG OF SITE CONDITIONS IN • EARTHEN -MATERIAL STOCKPILES MUST BE LOCATED 50' FROM z w ACCORDANCE WITH NPDES PERMIT. MAINTENANCE INSPECTIONS SHALL BE PERFORMED cn STORM DRAINS AND STREAMS UNLESS NO REASONABLE Li WEEKLY AND AFTER EACH RAINFALL. ALL REPAIRS NECESSARY SHOULD BE MADE ALTERNATIVES AVAILABLE. IMMEDIATELY AND IN STRICT ACCORDANCE WITH NCDEQ STANDARDS AND NPDES PERMIT. • CONCRETE MATERIALS MUST BE CONTROLLED TO AVOID CONTACT CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS WITH SURFACE WATERS, WETLANDS, OR BUFFERS. FOR PREPARATION OF FINAL RECORD DRAWINGS. 17. ALL SLOPES STEEPER THAN 2:1 SLOPE AND OVER 5' IN HEIGHT SHALL BE CERTIFIED BY A 3 DISCHARGES ,TO FEDERALLY -LISTED WATERS LICENSED PROFESSIONAL. • REQUIREMENTS ARE THE SAME AS IN PREVIOUS PERMIT. 18. CONTRACTOR IS REQUIRED TO OBTAIN AND PROVIDE A COPY OF THE EROSION CONTROL • THE PERMIT ALLOWS REDUCTION FROM THE 20 ACRE MINIMUM IF PERMIT FOR ANY OFFSITE BORROW/ SPOIL AREA. CONTRACTOR MUST PROVIDE COPY OF THE DIRECTOR OF DWQ DETERMINES THAT OTHER BMPS PROVIDE PERMIT TO NCDEQ INSPECTOR PRIOR TO CONSTRUCTION. EQUIVALENT PROTECTION. 19. IF BORROWED OR WASTE FILL MATERIAL IS GENERATED, AN APPROVED GRADING PERMIT MUST BE SECURED FOR THE BORROW OR WASTE MATERIAL SITE PRIOR TO INITIATION OF 4) INSPECTIONS ANY LAND DISTURBING ACTIVITY • SAME WEEKLY INSPECTION REQUIREMENTS. 20. ALL FILL SLOPES SHALL BE COMPACTED FULL DEPTH TO NOT LESS THAN 95% MAXIMUM • SAME RAIN GAUGE & INSPECTIONS AFTER 0.5" RAIN EVENT. DENSITY (STANDARD PROCTOR), SHALL BE PLACED ON A SURFACE CLEARED OF GROWTH • INSPECTIONS ARE ONLY REQUIRED DURING "NORMAL BUSINESS AND DEBRIS, AND BE PROPERLY BENCHED AND DRAINED. HOURS." • RECORDS MUST BE KEPT FOR 3 YEARS AND AVAILABLE ON-SITE 21. COMPACTION REPORTS MUST BE PROVIDED TO THE OWNER AND ENGINEER INDICATING THAT DURING BUSINESS HOURS UNLESS A SITE-SPECIFIC EXEMPTION IS FILL HAS BEEN COMPACTED TO NOT LESS THAN 95% MAXIMUM DENSITY (STANDARD APPROVED. PROCTOR). • RECORDS MUST BE KEPT FOR 3 YEARS AND AVAILABLE UPON REQUEST. 22. ALL FILL MATERIAL, UNLESS A PERMIT FROM NCDEQ DIVISION OF WASTE MANAGEMENT TO • ELECTRON ICALLY-AVAILABE RECORDS MAY BE SUBSTITUTED UNDER OPERATE A LANDFILL IS ON FILE FOR THE OFFICAL SITE, SHALL BE FREE OF ORGANIC OR CERTAIN CONDITIONS. OTHER DEGRADABLE MATERIALS, MASONRY, CONCRETE AND BRICK SIZES EXCEEDING 12 INCHES, AND ANY MATERIALS WHICH COULD CAUSE THE SITE TO BE REGULATED AS A LANDFILL BY THE STATE OF NORTH CAROLINA. 5) IMPLEMENTATION OF NEW PERMIT CONDITIONS • PROJECTS PERMITTED UNDER THE PREVIOUS PERMIT CAN CONTINUE TO FOLLOW THE PREVIOUSLY -PERMITTED CONDITIONS. • COMPLETE APPLICATIONS RECEIVED PRIOR TO AUGUST 3, 2011 CAN FOLLOW CONDITIONS OF APPROVED APPLICATION. • APPLICATIONS RECEIVED AFTER AUGUST 2, 2011 MUST COMPLY WITH NEW PERMIT CONDITIONS. 6) CONDITIONS IN EROSION & SEDIMENTATION CONTROL PLANS • DESIGNATION ON THE PLANS WHERE 7 AND 14 -DAY GROUND STABILIZATION REQUIREMENTS ON THE NPDES PERMIT APPLY. • DESIGNATION ON THE PLANS WHERE BASINS THAT COMPLY WITH THE SURFACE -WITHDRAWAL REQUIREMENTS OF THE NPDES PERMIT ARE LOCATED. 7) SEDIMENT BASINS • OUTLET STRUCTURES MUST WITHDRAW FROM BASIN SURFACE UNLESS DRAINAGE AREA IS LESS THAN 1 ACRE. • USE ONLY DWQ-APPROVED FLOCCULANTS. STORM DRAINAGE DETAILS :) 00 o Lu 000 - U) Z W LO N W C4 F- W v 0 44 a NN Z 5 N co 0 V V 0 J N N .z W W N N r J W W W J W W F-> W x a w Z Q co W COm0U. m OLL Q a Z Q a ¢3 Q 3 N E 0 Qy a .. 0 N u ^ a� w m .5 �> 0 O 3 Ono 3 � m � p J � 0 0 J J It: J Q 07 Q m m z N m � m chbi� I- p D � p � D o 0 0 V) 0 00 cn o 0 0 00 N i U W N z W 0 J N J W m 0 z z 0 w 0 m w p V z M� I..L Q z Ww J \ / Q 0 0 0 Q z w Li_ J 0 J J M L.L � 0 I ~ o Ll Z 0 J W % Q w V Z p w � ' Q z J Q z Q o o Q 0 o' p V z w � m o cn Li DRAWN BY:CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET C941 ALL NON—FERROUS UNDERGROUND LINES OUTSIDE BUILDING FOOTPRINT SHALL BE REQUIRED TO HAVE A MAGNETIC—TYPE WARNING TAPE INSTALLED IN THE BACKFILL AT LEAST 6" BELOW GRADE. SPRINGLINE FINAL BACKFILL (SEE SPECIFICATION FOR COMPACTION REQUIREMENT) z Ch Ld LLI :2 U Q m => w J m Z X :2 w J U_ INITIAL BACKFILL (COMPACTED TO 98% OF STANDARD PROCTOR) HAUNCH (COMPACTED TO 98% OF STANDARD PROCTOR) BEDDING (COMPACTED TO 98% OF STANDARD PROCTOR) 0_a_ m m SUITABLE � Z FOUNDATION (V 49 I I MIN. TRENCH WIDTH o (SEE TABLE) MINIMUM TRENCH WIDTHS PIPE DIAMETER MIN. TRENCH WIDTH 12" 30" 15" 34" 18" 39" 24" 48" 30" 56" 36" 64" 42 72" 48 80" 54" 88" 60" 96" MAXIMUM COVER PIPE DIAMETER CLASS 1 CLASS II CLASS III 12" 43' 28' 20' 15" 43' 28' 20' 18" 43' 28' 20' 24" 34' 23' 17' 30" 34' 23' 17' 36" 34' 23' 16' 42" 34' 23' 16' 48" 31 21' 15' 54" 31' 21' 15' 60" 31' 21' 15' w *ASSUMED PIPE BACKFILL IS PLACED AND COMPACTED TO THE REQUIRED 98% OF THE STANDARD PROCTOR NOTES: 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH LATEST EDITION OF ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", AND THE PROJECT SPECIFICATIONS. 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II, OR, III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4"(100 mm) FOR 12"-24" (100 mm — 600 mm); 6"(150 mm) FOR 30"-60" (750 mm — 900 mm). 5. HAUNCHING/INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, 11, OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. 6. MINIMUM COVER: MINIMUM COVER, H, IN NON—TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT. HEAVY CONSTRUCTION LOADS MAY REQUIRE ADDITIONAL COVER TO PROTECT THE PIPE. CONTRACTOR TO VERIFY THAT CONSTRUCTION LOADS WILL NOT DAMAGE INSTALLED PIPES AND PROTECT INSTALLED PIPES IF REQUIRED. 7. MAXIMUM COVER: MAXIMUM COVER SHALL BE MEASURED FROM THE FINISHED SURFACE OF THE GROUND TO THE TOP OF THE PIPE, AND SHALL BE LESS THAN THE MAXIMUM VALUES SHOWN IN THE CHART WITHIN THIS DETAIL. HDPE TRENCH INSTALLATION DETAIL NOT TO SCALE Dewatering Device or dirt/sediment bag) Discharge Hose Dewatering Pump P (as needed) A A Flow Work Area Sandbag/Stone Barrier P Discharge Hose f Discharge Pump Into Velocity Work Area Dissipater Length Not To Exceed That Which Can Be Completed In One Day Sump—hole Or Pool 12 Min Depth Flow 2' Min Diameter Intake Hose Diversion Pump Sheeting Base Flow + 1 Foot Work Area (2 Foot Minimum) Cross Section Of Sandbag/Stone Diversion SECTION A -A PUMP AROUND / DEWATERING PLAN VIEW DETAIL NOT TO SCALE TOP VIEW F = SEWN IN NECK DIRTBAG 3 `2 OPENING ACCOMODATES UP TO 4' DISCHARGE LENGTH HOSE NOTES: 1) DIRTBAG TO BE PLACED ON AGGREGATE OR STRAW 2) SEAMS MUST BE HIGH STRENGTH DOUBLE STITCHED "J" SEAMS 3) SEAM MUST BE TESTED UNDER ASTM D-4884. ACF TEST RESULTS AVAILABLE UPON REQUEST 4) THIS WORK SHALL CONSIST OF FURNISHING, PLACING AND REMOVAL OF ASSOCIATED DEVICE 4) CONTRACTOR IS REQUIRED TO USE A DIRTBAG DB -55 OR APPROVED EQUIVELENT CROSS SECTION LL J R--4 oQU)x T T5 #4 2'- 6 36 60 DB55 FABRIC PROPERTIES PROPERTY TEST METHOD MARV TENSILE STRENGTH ASTM D-4632 205 LBS ELONGATION ASTM D-4632 50% CBR PUNCTURE ASTM D-6241 525 LBS UV RESISTANCE ASTM D-4355 70° AOS ASTM D-4751 80 US SIEVE PERMITTIVITY ASTM D-4491 1,4 SEC -1 FLOW RATE ASTM D-4491 90 GPM/SF CORPORATE OFFICE T4 2831 CARDWELL ROAD ACF DB55 DIRTBAG RICHMOND, VA 23234 PH 800-448-3636 FOR ADDITIONAL INFORMATION PLEASE CONTACT ACF ENVIRONMENTAL [FT'S GEi li OONF WWW.ACFENVIRONMENTALCOM PH: N0-448-3636 / WWW.ACFENVIRONMENTALCOM DEWATERING BAG NOT TO SCALE Q Q m H U <� F-4 z rQQx[n HZ� ]> O > y M W z _ [n D 0 0 • �] H :z --A 1 Cn 27 71m a M m M 2 z H 0 H 0 0 z r M 0 Cn o C7 z z p a 2 _Ux H 0 a M m o Do 'mz to H a = 0 A o rn a � r r SHEET 1 OF 2 838.27 T1 TOP & BOTTOM 2'_16,r 4'-6" T5 @ 6" TOP & BOTTOM 11%s" I 5 SPA. @ 11" Z" BARS IN TOP OF FOOTING Z1 v � I Z2 ek I - lSLr �,, � � 3-N1 s'' I T4 Z3 rp., 71/4,� I 3 - N2 2'-ii�is'r —5 SPA. @ 11" "N" BARS 9" 2, 7 r, IN BOTTOM OF FOOTING 3' PLAN 2-G1 _F B I 2-V1 @ 9" FILL FACE 1-V1 STR. FACE r 2-B2 ti as 3" DIA. DRAINS r 6d i 8" ABOVE FLOW LINE L? CONST. JT. 2-B1 2 N1 r B ELEVATION N+1 z z Z1 3'-9" 7 3112 �- �L - Z2 3'-3" ZN v ti Z3 21 B,r fir, N N H1 5'-5" H2 3'-5" 1'_1'=1 l— �HK. "H" BARS "N" BARS "Z" BARS "H", "N", & "Z" BAR DIMENSIONS ARE OUT TO OUT. 8" MIN CULVERT SHALL BE BURIED 1.0' MINIMUM BELOW STREAM BED ELEVATION 1o" 2-rrGrr "4 2 r orf V1 @ V -s" & WING WALL 6 - /—FILL FACE V1 La 9" @ WING WALL PIPE NOT SHOWN T5 @ 6" SECTION - BB 2'�� SECTION - AA STD. # 838.45 FOR GENERAL NOTES. z � ~ Q FILL FACE W 4 1 W a r --I a a J z 0 LL `2 REINF. STEEL 1 PIPE Q � � ' B1 #4 5'-6" 4 15 82 #4 4f-6" 4 12 G1 #7 8'-8" 2 35 H1 #4 fir -0" 10 40 Z � "V f, @ 1 1 " N2 #4 31- 5'I 6 14 r, V r, p 1 ' - 10 " LL J R--4 oQU)x T4 #4 5'-fi" 6 22Cn T5 #4 2'- 6 36 60 H,r V2 #4 5' -1 " 6 20 wQrr zLL= "fir, Z1 #5 4'-4" 4 18 Z3 #4 3'-2" 4 S 'I-4 N r jL T4 < _ LL J r T4 CC H O Q iia Z H - �y CV m CL J, r w 0 ATRFA7lrE*'l @ 11" FILL 2 SPA. @ 1'-101"-V2, 2-V3, 2-V4 FACE 2-H1, 1-H2 3 SPA. @ 1`-3" FILL H FACE 3 -Hi, 1-H2�FILLAFACEI-101-V2, 1-V3, 1-VV4 FH1 11 CV T4 3-N1 3-142 5 SPA. @ 11" WING ELEVATION 18" MIN SECTION SEE 4 - AA STD. # 838.45 FOR GENERAL NOTES. r LL a Z O ❑ � 00 Q �- C.3 LU J J Q 0 Z W LV W CC Z 0 0 W V U6 I= -I LV W 4 1 W a r --I a a J z 0 LL BILL OF MATERIAL FOR EHDWALL REINF. STEEL 1 PIPE BAR SIZE LENGTH NO r WEIGHT B1 #4 5'-6" 4 15 82 #4 4f-6" 4 12 G1 #7 8'-8" 2 35 H1 #4 fir -0" 10 40 H2 #4 4'-0" 4 11 N1 #5 3'-11" 10 41 N2 #4 31- 5'I 6 14 Z Q a 1.1 #4 12'-8" 6 51 T4 #4 5'-fi" 6 22Cn T5 #4 2'- 6 36 60 V1 #4 6'-3 6 25 V2 #4 5' -1 " 6 20 V3 #4 .3' - 11 " 6 16 V4 #4 2'-9" 6 11 Z1 #5 4'-4" 4 18 Z2 #4 3'-10" 4 10 Z3 #4 3'-2" 4 S CULVERT SHALL BE BACKFILLED WITH ENGINEERED FILLED. PLACED AND COMPACTED IN 6" LIFTS #57 STONE TO 0 0 0 0 0 o SPRINGLINE OF PIPE 12} MIN o 0 0 0 0 o BEDDING 0 0 0 0 0 0 (COMPACTED TO 98% OF STANDARD PROCTOR) #57 STONE WRAPPED IN MIRAFI 140 N OR EQUIVALENT MIN. TRENCH WIDTH CULVERT INSTALLATION DETAIL NOT TO SCALE REINF. STEEL LBS. 4 0 9 SHEET 1 OF 2 CQN.IR.C. CU. YDS 5.6 1838.27 STREAM CROSSING DETAILS W O00(DLU OD a' Of°-LL0 O fL6 LU � r, 1* Oo LL0N LO N LO `�"V C4LO C4 r Z V CO CO OLU J ONvO W Lu w J co �ONCO cc W= O U_ w OCO LL a CL Z Q a a� 3 N LO o ado Leo co 0 0 0 v ao T N LU z w U J J LU m U z IN z a z J O Q U 0 z Li w O J J U I Of w > z a z J O a U Z w w DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET C942 TEMPORARY COVER FOR CONSTRUCTION LOADS HEIGHT OF COVER FINISHED GRADE ACCESS CASTING TO BE PROVI DED AN D INSTALLED BY CONTRACTOR. 4 I Q.-_ra__ _Ir r r v�I•r 1_ CONSTRUCTION LOADS FOR TEMPORARY CONSTRUCTION VEH ICLE LOADS, AN EXTRA AMOUNT OF COM PACTED COVER MAY BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT -OF -COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. GASKET MATERIAL 0 CMP RISERJ SUFFICIENTTO PREVENT SLAB FROM BEARING ON RISER TO BE PROVIDED BY CONTRACTOR. 08 1,' TYP. C a -- �w ay THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED INCHES 18-50 1 50-76 1 75-110 1 110-150 GRADE COVER MINIMUMS FOR NORMAL H IGHWAY TRAFFIC. MINIMUM COVER `MINIMUM COVER MAYVARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM SCALE: N.T.S. C'O #4 DIAGONAL TRIM BAR (TYP. 4 PLACES), SEE NOTE 7. OPENING IN PROTECTION SLAB FOR CASTING SCOPE PIPE PIPE SPAN, AXLE LOADS (kips) INCHES 18-50 1 50-76 1 75-110 1 110-150 THE DESIGNED DETENTION SYSTEM DETAILED IN THE PROJECT PLANS. MINIMUM COVER (FT) ALUMINIZED TYPE 2: AASHTO M-36 OR ASTM A-760 2.0 2.5 3.0 3.0 12-42 48-72 3.0 3.0 3.5 4.0 78-120 3.0 3.5 4.0 4.0 126-144 3.5 4.0 4.5 4.5 `MINIMUM COVER MAYVARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM SCALE: N.T.S. C'O #4 DIAGONAL TRIM BAR (TYP. 4 PLACES), SEE NOTE 7. OPENING IN PROTECTION SLAB FOR CASTING SCOPE PIPE STANDARD STANDARD THIS SPECIFICATION COVERS THE MANUFACTURE AND INSTALLATION OF THE PIPE SHALL BE MANUFACTURED IN ACCORDANCE TO THE APPLICABLE "BEARING THE DESIGNED DETENTION SYSTEM DETAILED IN THE PROJECT PLANS. REQUIREMENTS LISTED BELOW: O B MATERIAL ALUMINIZED TYPE 2: AASHTO M-36 OR ASTM A-760 INTERRUPTED BAR THE MATERIAL SHALL CONFORM TO THE APPLICABLE REQUIREMENTS ALUMINUM: AASHTO M-196 OR ASTM B-745 REPLACEMENT, SEE NOTE 6. LISTED BELOW: GALVANIZED: AASHTO M-36 OR ASTM A-760 04' OA OB #4 DIAGONAL TRIM BAR (TYP.4 PLACES), - SEE NOTE 7. 2' COVER (TYP) CP jAl / OPENING IN PROTECTION SLAB FOR CASTING REINFORCING TABLE GEOMEMBRANE BARRIER STANDARD STANDARD • �- _ ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE "BEARING O CMP A O B REINFORCING PRESSURE RISER PROJECT NAME: WCU -Central Drive Parking Lot ALUMINUM: AASHTO M-196 OR ASTM B-745 Iu°aBb""•esrel.n:s°°s^"«a.m°w wube�nr"me mMrwW.ContechEs.com (PSF) 24' 04' 261, #5@12"OCEW 2,410 HANDLING AND ASSEMBLY 4'X4' 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 #5 @ 12" OCEW 1,780 30" 04'-6'#5@12"OCEW 32" PIPE ASSOCIATION) FOR ALUMINIZED TYPE 2, GALVANIZED OR POLYMER 2,120 REVISION DESCRIPTION BY 4'-6' X 4'-6' COATED STEEL. SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S #5 @ 12" OCEW 1,530 38' 0 5' �" #5 @ 10" OCEW 1,890 DOWNSTREAM END WITH THE OUTLET ALREADY CONSTRUCTED TO ALLOW 5'X 5' BARS A MINIMUM OF 12' BEYOND OPENING, BEND #5 @ 10" OCEW 1,350 42' 05'-6'#5@10"OCEW 44" SHALL BE IN ACCORDANCE WITH AASHTO STANDARD SPECIFICATIONS FOR 1,720 AGENTS WILL BE USED ON OR NEAR THE PROJECT SITE, AND USE HIS/HER BEST 5'-6' X 5'-6' HIGHWAY BRIDGES, SECTION 26, DIVISION II DIVISION II OR ASTM A-798 (FOR #5 @ 9" OCEW 1,210 48' 06'#5@9"OCEW 1. PROVIDED AN D INSTALLED BY CONTRACTOR. 1,600 B-788 (FOR ALUMINUM PIPE)AND IN CONFORMANCE WITH THE PROJECT 6X6, GEOMEMBRANE BARRIER FOR PROJECTS WHERE SALTING AGENTS ARE USED ONINLET #5@8"OCEW 1,100 "ASSUMED SOIL BEARINGCAPACITY CMP DETENTION INSTALLATION GUIDE GEOMEMBRANE BARRIER STANDARD STANDARD • �- _ ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE NEW, EN REINFORCING, REINFORCING, CMP DETENTION INSTALLATION GUIDE GEOMEMBRANE BARRIER STANDARD STANDARD • �- _ ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE POLYMER COATED: AASHTO M -2450R ASTM A-762 REINFORCING, REINFORCING, 0B INTERRUPTED BAR w REPLACEMENT, APPLICABLE REQUIREMENTS OF AASHTO M-274 OR ASTM A-92. �/�� ENGINEERED SOLUTIONS LLC SEETABLE SEE TABLE SEE NOTE 6. PROJECT NAME: WCU -Central Drive Parking Lot ALUMINUM: AASHTO M-196 OR ASTM B-745 Iu°aBb""•esrel.n:s°°s^"«a.m°w wube�nr"me mMrwW.ContechEs.com • ABOVE PIPE = 0 IN THE GALVANIZED STEEL COILS SHALL CONFORM TO THE CONTECH ROUND OPTION PLAN VIEW SQUARE OPTION PLAN VIEW APPLICABLE REQUIREMENTSOFAASHTOM-2180RASTMA-929. HANDLING AND ASSEMBLY SYSTEMS OFTEN REQUIRES SPECIAL CONSTRUCTION PRACTICES THAT 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 SHALL BE IN ACCORDANCE WITH NCSP'S (NATIONAL CORRUGATED STEEL TYPE 2 (ALT2) CAN RAPIDLY FILL THE EXCAVATION; POTENTIALLY CAU SIN G FLOATATION THE POLYMER COATED STEEL COILS SHALL CONFORM TO THE PIPE ASSOCIATION) FOR ALUMINIZED TYPE 2, GALVANIZED OR POLYMER NOTES: REVISION DESCRIPTION BY APPLICABLE REQUIREMENTS OF AASHTO M-246 OR ASTM A-742. COATED STEEL. SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S DRAWING EFFECTS THAT MAY RESULT FROM THE USE OF SUCH AGENTS INCLUDING ,� RECOMMENDATIONS FOR ALUMINUM PIPE. 1. DESIGN IN ACCORDANCE WITH AASHTO, 17th EDITION. 7. TRIM OPENING WITH DIAGONAL#4 BARS, EXTEND THE ALUMINUM COILS SHALL CONFORMTOTHE APPLICABLE DOWNSTREAM END WITH THE OUTLET ALREADY CONSTRUCTED TO ALLOW DETERMINE IF ADDTIONAL MEASURES, NOT COVERED IN THIS GUIDE, ARE BARS A MINIMUM OF 12' BEYOND OPENING, BEND REQUIREMENTS OF AASHTO M-197 OR ASTM B-744. INSTALLATION 2. DESIGN LOAD HS25. BARS AS REQUIRED TO MAINTAIN BAR COVER. IF AASHTOT99 PROCEDURESARE DETERMINED INFEASIBLE BYTHE SHALL BE IN ACCORDANCE WITH AASHTO STANDARD SPECIFICATIONS FOR AGENTS WILL BE USED ON OR NEAR THE PROJECT SITE, AND USE HIS/HER BEST CONSTRUCTION LOADS HIGHWAY BRIDGES, SECTION 26, DIVISION II DIVISION II OR ASTM A-798 (FOR 3. EARTH COVER = V MAX. 8. PROTECTION SLAB AND ALL MATERIALS TO BE CONSTRUCTION LOADS MAY BE HIGHER THAN FINAL LOADS. FOLLOW THE ALUMINIZED TYPE 2, GALVANIZED OR POLYMER COATED STEEL) OR ASTM FOUNDATION PROVIDED AN D INSTALLED BY CONTRACTOR. MANUFACTURER'S OR NCSPA W IDELINES. B-788 (FOR ALUMINUM PIPE)AND IN CONFORMANCE WITH THE PROJECT 4. CONCRETE STRENGTH =3,500 psi GEOMEMBRANE BARRIER FOR PROJECTS WHERE SALTING AGENTS ARE USED ONINLET UNDER THE COMPACTOR, OR UNDER FOOT, AN D THE GEOTECHN ICAL PLANSAND SPECIFICATIONS. IF THEREARE ANY INCONSISTENCIES OR CONSTRUCT A FOUN DATION THAT CAN SUPPORT THE DESIGN LOADING 9. DETAIL DESIGN BY DELTA ENGINEERING, BINGHAMTON, NY. CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE WITH THE 5. REINFORCING STEEL = ASTM A615, GRADE 60. ENGINEER OF RECORD (OR REPRESENTATIVE THEREOF) IS SATISFIED WITH SITE ENGINEER. MAINTAIN ITS INTEGRITY DURING CONSTRUCTION. =i.E . NOTE: 6. PROVIDE ADDITIONAL REIN FORCING AROUND MANHOLE CAP DETAIL THESE DRAWINGS ARE FOR CONCEPTUAL IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW OPENINGS EQUAL TO THE BARS INTERRUPTED, WATER ELEVATION Iry PURPOSES AND DO NOT REFLECT ANY LOCAL OSHA GUIDELINES FOR SAFE PRACTICES. HALF EACH SIDE. ADDITIONAL BARS TO BE IN SCALE: N.T.S. PREFERENCES OR REGULATIONS. PLEASE E E EVATION APPROPRIATE ELEVATION WITH A COMPETENT BACKFILL MATERIAL. THE OMPET THE SAME PLANE. REACHES OR DRAGLINES WITH STONE BUCKETS MAY BE USED TO PLACE CONTACT YOUR LOCAL CONTECH REP FOR MODIFICATIONS. STRUCTURAL FILL MATERIAL GRADATION SHOULD NOT ALLOWIHS CMP DETENTION INSTALLATION GUIDE GEOMEMBRANE BARRIER C= :NTECHm • �- _ PROPER INSTALLATION OF A FLEXIBLE UN DERGROUND DETENTION SYSTEM ---- - 7981-3-0 _. ...----- .._.. ___..._.. 1-6/25120118 0 &25/2018 1°m'm'pma"Aa","'esne xi°��". or • LENGTH PER BARREL = 131 FT �/�� ENGINEERED SOLUTIONS LLC \� rrr� CMP DETENTION SYSTEMS SALTING AGENTS ARE USED, SUCH AS ROAD SALTS FOR DEICING AGENTS. IF PROJECT NAME: WCU -Central Drive Parking Lot DESIGNED: DRAVM: DESIGNED Ins Iu°aBb""•esrel.n:s°°s^"«a.m°w wube�nr"me mMrwW.ContechEs.com • ABOVE PIPE = 0 IN WILL ENSURE LONG-TERM PERFORMANCE. THE CONFIGURATION OF THESE CONTECH • GAGE = 14 Cullowhee, NC cHEc1a:0: eamovEo. BECAUSE MOST SYSTEMS ARE CONSTRUCTED BELOW-GRADE, RAIN FAIL L SYSTEMS OFTEN REQUIRES SPECIAL CONSTRUCTION PRACTICES THAT 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 DYODS TYPE 2 (ALT2) CAN RAPIDLY FILL THE EXCAVATION; POTENTIALLY CAU SIN G FLOATATION DESCRIPTION: WQV sHEErNo.. o -MARK DATE REVISION DESCRIPTION BY 800J38-1122 513-645-7000 513E45-7993 FAX AND MOVEMENT OF THE PREVIOUSLY PLACED PIPES. TOHELP MITIGATE DRAWING EFFECTS THAT MAY RESULT FROM THE USE OF SUCH AGENTS INCLUDING ,� POTENTIAL PROBLEMS, IT IS BESTTO STARTTHE INSTALLATION AT THE D3 CMP DETENTION INSTALLATION GUIDE GEOMEMBRANE BARRIER TO 21 UFTS(APPROX, 6,MRE0 C:�NTECH• MrMr ENGINEERED SOLUTIONS LLC CCcntechES.com 9025 Centre Pointe Dr., SURE 400, West Chester, OH 45069 PROPER INSTALLATION OF A FLEXIBLE UN DERGROUND DETENTION SYSTEM ASTE'S RESISTNITY MAY CHANGE OVER TIME AMEN VARIOUS TYPES OF PIPE DETAILS BACKFILL DETAILS • LENGTH PER BARREL = 131 FT ADDITIONAL CONSIDERATIONS • DIAMETER = 96 IN SALTING AGENTS ARE USED, SUCH AS ROAD SALTS FOR DEICING AGENTS. IF \ • PIPE STORAGE = 11,340 CF W/ 24" FREEBOARD BABWKMEM • ABOVE PIPE = 0 IN WILL ENSURE LONG-TERM PERFORMANCE. THE CONFIGURATION OF THESE SALTING AGENTS ARE USED ON OR NEAR TH E PROJECT SITE, A GEOMEMBRANE • GAGE = 14 RMA PIPES PIPE AMD • APPROX. CMP FOOTAGE = 281 FT BECAUSE MOST SYSTEMS ARE CONSTRUCTED BELOW-GRADE, RAIN FAIL L SYSTEMS OFTEN REQUIRES SPECIAL CONSTRUCTION PRACTICES THAT BARRIER IS RECOMMENDED WITH THE SYSTEM. THE GEOMEMBRANE LINER IS R TYPE 2 (ALT2) CAN RAPIDLY FILL THE EXCAVATION; POTENTIALLY CAU SIN G FLOATATION DIFFER FROM CONVENTIONAL FLEXIBLE PIPE CONSTRUCTION. CONTECH INTENDED TOHELP PROTECT THE SYSTEM FROM THE POTENTIAL ADVERSE \ / o VLL AND MOVEMENT OF THE PREVIOUSLY PLACED PIPES. TOHELP MITIGATE ENGINEERED SOLUTIONS STRONGLY SUGGESTS SCHEDULINGA EFFECTS THAT MAY RESULT FROM THE USE OF SUCH AGENTS INCLUDING ,� POTENTIAL PROBLEMS, IT IS BESTTO STARTTHE INSTALLATION AT THE PRE -CONSTRUCTION MEETING WITH YOUR LOCAL SALES ENGINEER TOPREMATURE CORROSION AND REDUCEDACTUAL SERVICE LIFE. a Of DOWNSTREAM END WITH THE OUTLET ALREADY CONSTRUCTED TO ALLOW DETERMINE IF ADDTIONAL MEASURES, NOT COVERED IN THIS GUIDE, ARE 8'LOOSE LIFTS BEDDING A ROUTE FOR THE WATER TO ESCAPE. TEMPORARY DIVERSION MEASURES APPROPRIATE FOR YOUR SITE. THE PROJECTS ENGINEER OF RECORD IS TO EVALUATE WHETHER SALTING IF AASHTOT99 PROCEDURESARE DETERMINED INFEASIBLE BYTHE MAY BE REQUIRED FOR HIGH FLOWS DUETOTHE RESTRICTED NATURE OF AGENTS WILL BE USED ON OR NEAR THE PROJECT SITE, AND USE HIS/HER BEST GEOTECHNICAL ENGINEER OF RECORD, COMPACTION IS CONSIDERED THE OUTLET PIPE. JUDGEMENT TO DETERMINE IF ANYADDITIONAL PROTECTIVE MEASURES ARE FOUNDATION REQUIRED. BELOW IS ATYPICAL DETAIL SHOWING THE PLACEMENT OF A ADEQUATE WHEN NO FURTHER',ELDING OF THE MATERIAL IS OBSERVED CATCH BASIN GEOMEMBRANE BARRIER FOR PROJECTS WHERE SALTING AGENTS ARE USED ONINLET UNDER THE COMPACTOR, OR UNDER FOOT, AN D THE GEOTECHN ICAL -DPARNNGLOT CONSTRUCT A FOUN DATION THAT CAN SUPPORT THE DESIGN LOADING OR NEAR THE PROJECT SITE. wATIBT_,-'NATE APPLIED BYTHE PIPE AND ADJACENT BACKFILL WEIGHT AS WELL AS ENGINEER OF RECORD (OR REPRESENTATIVE THEREOF) IS SATISFIED WITH MAINTAIN ITS INTEGRITY DURING CONSTRUCTION. =i.E . THE LEVEL OF COMPACTION. r IF SOFT OR UNSUITABLE SOILS ARE ENCOUNTERED, REMOVE THE POOR % 4 ' ": t)'� �7, WATER ELEVATION Iry SOILS DOWN DEPTHAN D EN BUILDUP TO THE eer�cou FOR LARGE SYSTEMS, CONVEYOR SYSTEMS, BACKHOES WITH LONG DETENTION SYSTEM E E EVATION APPROPRIATE ELEVATION WITH A COMPETENT BACKFILL MATERIAL. THE OMPET - REACHES OR DRAGLINES WITH STONE BUCKETS MAY BE USED TO PLACE STRUCTURAL FILL MATERIAL GRADATION SHOULD NOT ALLOWIHS ONCE MINIMUM COVER FOR CONSTRUCTION LOADING ACROSS FINISHED FUNCTIONING SYSTEMBACKFILL. OUTLET CONTROL MIGRATION OF FINES, WHICH CAN CAUSE SETTLEMENT OF THE DETENTION THE ENTIRE WIDTH OF THE SYSTEM IS REACHED, ADVANCE THE EQUIPMENT SYSTEM OR PAVEMENT ABOVE. IF THE STRUCTURAL FILL MATERIAL IS NOT TO THE END OF THE RECENTLY PLACED FILL, AND BEGIN THE SEQUENCE CMP DETENTION SYSTEM INSPECTION AND COMPATIBLE WITH THE UNDERLYING SOILS AN ENGINEERING FABRIC IN-SITU TRENCH WALL AGAIN UNTILTHE SYSTEM IS COMPLETELY BACKFILLED. THISTYPE OF MAINTENANCE SHOULD BE USED ASA SEPARATOR. IN SOME CASES, USING ASTIFF IF EXCAVATION IS REQUIRED, THE TRENCH WALL NEEDS CAPABLE CONSTRUCTION SEQUENCE PROVIDES ROOM FOR STOCKPILED BACKFILL UNDERGROUND STORMWATER DETENTION AND INFILTRATION SYSTEMS MUST REINFORCING GEOGRID REDUCES OVER EXCAVATION AND REPLACEMENT DIRECTLY BEHIND THE BACKHOE, AS WELL AS THE MOVEMENT OF BE INSPECTED AND MAINTAINED AT REGULAR INTERVALS FOR PURPOSES OF FILL QUANTITIES. SBE LOAD THATTHE PIPE SHEDS D. SUPPORTINGT THE SYSTEM IS LOADED. IF CONSTRUCTION TRAFFIC. MATERIAL STOCKPILES ON TOP OF THE PERFORMANCE AND LONGEVITY. SOI C E DEFLECT. AR NOT CAPABLE OF SIMPLE SOIL PRESSURTING RE USINGS, TH E HE CAN A E CHECK GESPRING BACKFILLED DETENTION SYSTEM SHOULD BE LIMTEDTO 8 -TO 10 -FEET HIGH INSPECTION LOADEFLECT. DERFRMINETORM BEYOND MINE THE LIMITS OF EXCAVATION BEYOND THE SPRING LINE OF LIMITS OF EXCAVATION LI AND MUST PROVIDE BALANCED LOADING ACROSS ALL BARRELS. TO MOST THE OUTER MOST PIPES. THE OUTER DETERMINE THE PROPER COVER OVER THE PIPES TO ALLOW THE INSPECTION IS THE KEY TO EFFECTIVE MAINTENANCE OF CMP DETENTION BAcla=lu °OAR MOVEMENT OF CONSTRUCTION EQUIPMENT SEE TABLE 1, OR CONTACT SYSTEMS AND IS EASILY PERFORMED. CONTECH RECOMMENDS ONGOING, GEOGRIDUSEDTOREDUCE IN MOST CASES THE REQU IREMENTS FOR A SAFE WORK ENVIRONMENT AND YOUR LOCAL CONTECH SALES ENGINEER. QUARTERLY INSPECTIONS. THE RATE ATMICH THE SYSTEM COLLECTS THE AMOUNT OF UNDERCUT OEOGRID WASN'TUSED PROPER BACKFILL PLACEMENT AND COMPACTION TAKE CARE OF THIS CONCERN. POLLUTANTS WILL DEPEND MORE ON STE SPECIFIC ACTIVTIES RATHER THAN THE SIZE OR CONFIGURATION OF THE SYSTEM. enawlu.ENr ivMCAL MClffi LL SE W ENCS I BACKFILL MATERIAL - - - - _ INSPECTIONS SHOULD BE PERFORMED MORE OFTEN IN EQUIPMENT /EMBANKMENT WASHDOWN AREAS, IN CLIMATES WHERE SAN DING AND/OR SALTING TYPICALLY, THE BEST BACKFILL MATERIAL IS AN ANGULAR, WELL -GRADED, a '� T OPERATIONS TAKE PLACE, AND IN OTHER VARIOUS INSTANCES IN WHICH ONE GRANULAR FILL MEETING TH E REQUIREMENTS OF AASHTO A-11, A-2 OR \ '^ T WOULD EXPECT HIGHER ACCUMULATIONS OF SEDIMENT OR ABRASIVE/ A-3. IN SOME CASES, IT MAYBE DESIRABLE TO USE A UNIFORMLY GRADED _ - _ - _ CORROSIVE CON DTIONS. A RECORD OF EACH INSPECTION IS TO BE I GEOGRI UNDERCUTAND REPLACE TYPE MATERIAL FOR THE FIRST 18 -TO 24 -INCHES. THIS TE OF MATERIAL IS EASIER / MAINTAINED FOR THE LIFE OF THE SYSTEM = BED NO UNSUITABLE SOILS TO PLACE UNDER THE HAUNCHES OF THE PIPE AND REQUIRES LITTLE COMPACTNE EFFORT. DEPENDING ON THE BEDDING MATERIAL, A SEPARATION WHEN PLOWABLE FILL IS USED, YOU MUST PREVENT PIPE FLOATATION. GEOTEXTILE MIGHT BE REQUIRED ABOVE AND BELOW THESE INITIAL LIFTS. MAINTENANCE GRADE THE FOUNDATION SUBGRADE TO A UNIFORM OR SLIGHTLY SLOPING TYPICALLY, SMALL LIFTS ARE PLACED BETWEEN THE PIPES AND THEN CMP DETENTION SYSTEMS SHOULD BE CLEANED WHEN AN INSPECTION GRADE. IF THE SUBGRADE IS CLAYOR RELATIVELY NONPOROUS AND THEQ MCKA-WELLORADED }GRANULPRANDSMALLER ALLOWEDTO SET-UP PRIOR TOTHE PLACEMENTOF THE NEXT LIFT. THE ALLOWABLE THICKNESS OF TH E CLSM LIFT IS A FUNCTION OF A PROPER REVEALS ACCUMULATED SEDIMENT OR TRASH IS CLOGGING THE DISCHARGE CONSTRUCTION SEQUENCE WILL LAST FOR AN EXTENDED PERIOD OF TIME, T IS BEST TO SLOPE THE GRADE TO ONE EN D OF THE SYSTEM. TH IS WILL uoE LOAD f BALANCE BETWEEN TH E UPLIFT FORCE OF THE CLSM, THE OPPOSING ORIFICE. ALLOW EXCESS WATER TO DRAIN QUICKLY, PREVENTING SATURATION OF EMBANKMENT WEIGHT OF THE PIPE, AND THE EFFECT OF OTHER RESTRAINING MEASURES. ACCUMULATED SEDIMENT AND TRASH CAN TYPICALLY BE EVACUATED THE SUBGRADE. THE PIPE CAN CARRY LIMITED FLUID PRESSURE WITHOUT PIPE DISTORTION THROUGH THE MANHOLE OVER THE OUTLET ORIFICE. IF MAINTENANCE IS NOT - OR DISPLACEMENT, WHICH ALSO AFFECTS THE CLSM LIFT THICKNESS. YOUR PERFORMED AS RECOMMENDED, SEDIMENTAND TRASH MAYACCUMULATE IN BEDDING - GEOTIXTILE SEPARATION ABovE AND eEl_ow LOCAL CONTECH SALES ENGINEER CAN HELP DETERMINE THE PROPER LIFT FRONT OF THE OUTLET ORIFICE. MANHOLE COVERS SHOULD BE SECURELY BEDDING) `MIH UNIFORMLv THICKNESS. SEATED FOLLOWING CLEANING ACTIVITIES. CONTECH SUGGESTS THAT ALL A4 TO 6 -INCH THICK, WELL -GRADED, GRANULAR MATERIAL ISTHE GRADED BEDDING DYER. SYSTEMS BE DESIGNED WITH AN ACCESS/INSPECTION MANHOLE SITUATED AT ' PREFERRED PIPE BEDDING. IF CONSTRUCTION EQU IPMENT WILL OPERATE Be°DINc-WBUGRAr>ED STAGE POURS AS REQUIRED TO OR NEAR THE INLET AND THE OUTLET ORIFICE. SHOULD T BE NECESSARY TO FOR AN EXTENDED PERIOD OF TIME ON THE BEDDING, USE EITHER AN GLAR AND SMALLER CONTROL FLOATATION AND PIPE DISTORTIONMISPIACEMENT GET INSIDE TH E SYSTEM TO PERFORM MAINTENANCE ACTIVITIES, ALL I ENGINEERING FABRIC OR A STIFF GEOGRID TO ENSURE THE BASE OPEN -GRADED FILL IS TYPICALLY NOT USED BEYOND THE INITIAL 1 B -TO CLSM APPROPRIATE PRECAUTIONS REGARDING CONFINED SPACE ENTRY AND 3 MATERIAL MAINTAINS ITS INTEGRITY. 24 -INCHES BECAUSE THIS TYPE OF FILL OFTEN DOES NOT PROVIDE ADEQUATE EMBANKMENT OSHA REGULATIONS SHOULD BE FOLLOWED. I USING AN OPEN -GRADED BEDDING MATERIAL IS ACCEPTABLE; HOWEVER, CONFINING RESTRAINT TO THE PIPES. IF AUNIFORMLY GRADED MATERIAL SYSTEMS ARE TO BE RINSED, INCLUDING ABOVE THE SPRING LINE, ANNUALLY AN ENGINEERING FABRIC SEPARATOR IS REQUIRED BETWEEN THE BASE (PARTICLES ALL ONE SIZE) IS USED, INSTALL A GEOTEXTILE SEPARATION FABRIC SOON AFTER THE SPRING THAW, AND AFTER ANY ADDITIONAL USE OF SALTING AND THE SUBGRADE. TO PREVENT THE MIGRATION OF FINES INTO THE BACKFILL. AGENTS, AS PART OF THE MAINTENANCE PROGRAM FOR ALL SYSTEMS WHERE GRADE THE BASE TOA SMOOTH, UNIFORM GRADE TO ALLOW FOR THE BACKFILL USING CONTROLLED LOW -STRENGTH MATERIAL (CLSM OR 'PLOWABLE SALTING AGENTS MAYACCUMULATE INSIDE THE PIPE. PROPER PLACEMENT OF THE PIPE. FILL") AMEN THE SPACING BETWEEN THE PIPES WILL NOTALLOW FOR WEIGHTEDPIPE WITH MOBILE CONCRETE BARRIERS MAINTAINING AN UNDERGROUND DETENTION OR INFILTRATION SYSTEM IS PLACEMENT AND ADEQUATE COMPACTION OF THE BACKFILL. WORK CLOSELY (OROTHERREMDJABLE WEIGHTS) EASIEST WHEN THERE IS NO FLOW ENTERING THE SYSTEM. FOR THIS I- PER FOOT OF W TH TME LOCAL CONTECH SALES ENGINEER REGARDING THE SPECIAL REASON, IT IS A GOOD I DEA TO SCH EDU LE TH E CLEANOUT DU RING DRY j COVER OR4-MIN, INSTALLATION TECHNIQU ES REQUI RED W-1EN USING CLS M. CONSTRUCTION LOADING WEATHER. ' 8EODING-WEILGRPDED EMBA•QMBJT TYPICALLY, THE MINIMUM COVER SPECIFIED FOR A PROJECTASSUMES H-20 cIRANULAR AND SMMLER LIVE LOAD. BECAUSE CONSTRUCTION LOADS OFTEN EXCEED DESIGN LIVE THE FOREGOING INSPECTION AND MAINTENANCE EFFORTS HELP ENSURE INSITU BACKFILL PLACEMENT LOADS, INCREASED TEMPORARY MINIMUM COVER REQUIREMENTSARE UNDERGROUND PIPE SYSTEMS USED FOR STORMWATER STORAGE CONTINUE i TRENCMWML PLACE BACKFILL IN 8 -INCH LOOSE LIFTS AND COMPACT TO 90% AASHTO T99 NECESSARY. SINCE CONSTRUCTION EQUIPMENT VARIES FROM JOBTO JOB, TO FUNCTION AS INTENDED BY IDENTIFYING RECOMMENDED REGULAR INSPECTION AND MAINTENANCE PRACTICES. INSPECTION AND MAINTENANCE STANDARD PROCTOR DENSITY. MATERIAL SHALL BE WORKED INTOTHE PIPE T IS BEST TOADDRESS EQUIPMENT SPECIFIC MINIMUM COVER RELATEDTO THE STRUCTURAL INTEGRITYOF THE PIPE OR THE SOUNDNESS r r r r r r r HAUNCHES BY MEANS OF SHOVEL -SLICING, RODDING, AIR TAMPER, VIBRATORY REQUIREMENTS WITH YOUR LOCAL CONTECH SALES ENGINEER DURING OF PIPE JOINT CONNECTIONS IS BEYONDTHE SCOPE OF THIS GUIDE. i ROD, OR OTHER EFFECTIVE METHODS. YCUR PRE -CONSTRUCTION MEETING. I m N«m•Mn avmmweaewnerepAM "0°�.I�,•m LL<� �,aN �\�I/!c A�\1/(cVTCAIJ° --- - 7981-3-0 PROTECT NA.: SED. N. MTS'. 7981-3 0 8/25/2018 m A ����� 0 : NTECHm ��r• DESIGNED: DMNN'. mm'gyie'"Aaop same,mtmn^^o,^e «a�»rm•. rr N„«NM«M«r IA ENGINEERED SOLUTIONS LLC CMP DETENTIONSYSTEMS - PROJECT NAME: WCU Central Drive Parking Lot IS WWW.ContechES.com CONTECHc Cullowhee, NC °evla•"�ga.sla.o"a,°"°,'a y,`a, 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 DYODS 800338-1122 513-645-7000 513345-7993 FAX DRAWING DESCRIPTION: WQV SHEET NO.: D4 an«, ••mggm Mann:"Issnc'I,om«`»« MARK DATE REVISION DESCRIPTION BV 7.0' i -,.V w X./imi ICE (INVERT: 2206.7') OUTLET CONTROL STRUCTURE WEIR WALL "B21' NOT TO SCALE BULKHEAD WALL (SEE DETAILS BY CONTECH FOR STANDARD DETAILS) NOT TO SCALE NOTE: THESE DRAWINGS ARE FOR CONCEPTUAL PURPOSES AND DO NOT REFLECT ANY LOCAL PREFERENCES OR REGULATIONS. PLEASE CONTACT YOUR LOCAL CONTECH REP FOR MODIFICATIONS. NOTES IO- CONNECTION TO STRUCTURE 'B2' STRUCTURE "B2" • ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BYTHE ENGINEER OF RECORD PRIOR TO RELEASING FOR FABRICATION. • ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998. • ALL RISERS AND STUBS ARE 2W x y" CORRUGATION AND 16 GAGE UNLESS OTHERWISE NOTED. • RISERS TO BE FIELD TRIMMED TO GRADE. • QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR. • BAND TYPE TO BE DETERMINED UPON FINAL DESIGN. • THE PROJECT SUMMARY IS REFLECTIVE OF THE DYODS DESIGN, QUANTITIES ARE APPROX. AND SHOULD BE VERIFIED UPON FINAL DESIGN AND APPROVAL. FOR EXAMPLE, TOTAL EXCAVATION DOES NOT CONSIDER ALL VARIABLES SUCH AS SHORING AND ONLY ACCOUNTS FOR MATERIAL WITHIN THE ESTIMATED EXCAVATION FOOTPRINT. " u `I �a^o; Ielm , eniNnrH Po Ieiiirymr ^ so. aaiMi o: eon e. P «.»,"rorme"s"�aewan.,,.ml PROJECT SUMMARY # C:�NTECH• MrMr ENGINEERED SOLUTIONS LLC CCcntechES.com 9025 Centre Pointe Dr., SURE 400, West Chester, OH 45069 CALCULATION DETAILS STORAGE SUMMARY PIPE DETAILS BACKFILL DETAILS • LENGTH PER BARREL = 131 FT • STORAGE VOLUME REQUIRED 11,340 CF • DIAMETER = 96 IN • WIDTH AT ENDS = 24 IN • LENGTH PER HEADER = 19 FT • PIPE STORAGE = 11,340 CF W/ 24" FREEBOARD • CORRUGATION = 5" X 1" OR 3"X 1" • ABOVE PIPE = 0 IN • LOADING = H2O & H25 • STRUCTURAL BACKFILL STORAGE = 0 CF • GAGE = 14 • WIDTH AT SIDES = 24 IN • APPROX. CMP FOOTAGE = 281 FT • TOTAL STORAGE PROVIDED = 11,340 CF W/ 24" • COATING = ALUMINIZED STEEL • BELOW PIPE = 0 IN FREEBOARD TYPE 2 (ALT2) H Z `h IY • WALL TYPE = SOLID W o VLL z • BARREL SPACING = 36 IN a z_ O NOTES IO- CONNECTION TO STRUCTURE 'B2' STRUCTURE "B2" • ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BYTHE ENGINEER OF RECORD PRIOR TO RELEASING FOR FABRICATION. • ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998. • ALL RISERS AND STUBS ARE 2W x y" CORRUGATION AND 16 GAGE UNLESS OTHERWISE NOTED. • RISERS TO BE FIELD TRIMMED TO GRADE. • QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR. • BAND TYPE TO BE DETERMINED UPON FINAL DESIGN. • THE PROJECT SUMMARY IS REFLECTIVE OF THE DYODS DESIGN, QUANTITIES ARE APPROX. AND SHOULD BE VERIFIED UPON FINAL DESIGN AND APPROVAL. FOR EXAMPLE, TOTAL EXCAVATION DOES NOT CONSIDER ALL VARIABLES SUCH AS SHORING AND ONLY ACCOUNTS FOR MATERIAL WITHIN THE ESTIMATED EXCAVATION FOOTPRINT. " u `I �a^o; Ielm , eniNnrH Po Ieiiirymr ^ so. aaiMi o: eon e. P «.»,"rorme"s"�aewan.,,.ml # # # # C:�NTECH• MrMr ENGINEERED SOLUTIONS LLC CCcntechES.com 9025 Centre Pointe Dr., SURE 400, West Chester, OH 45069 -_ �� f�-�i► i �.Y� CMP DETENT N Y TEM DYODS DRnwmc ---- - 7981-3-0 PROJECT NAME: WCU - Central Drive Parkin 9 Lot Cullowhee, NC DESCRIPTION: WQV PROJECT No.: SED. No.: DATE: # # # # DESIGNED: DRAWN: # # # # # # # # CHECKED:CONTECH APPROVED: # # # # 800-338-1122 513-645-7000 513-645-7993 FAX :HEST NO, MARK DATE REVISION DESCRIPTION BY KEY 0 1. RIGID OR FLEXIBLE PAVEMENT 3 2. GRANULAR ROAD BASE 3. 12" MIN. FOR DIAMETERS THROUGH 96" 18" MIN. FOR DIAMETERS FROM 102' AND LARGER MEASURED TO TOP OF RIGID OR BOTTOM OF FLEXIBLE PAVEMENT. 4. SELECT GRANULAR FILL PER AASHTO M145 Al, A2 OR A3, OR APPROVED EQUAL. PLACED IN 8' LIFTS (COMPACTED TO MIN. 90% STANDARD DENSITY PER AASHTO T99.) 5. GRANULAR BEDDING, ROUGHLY SHAPED TO FT THE BOTTOM OF PIPE, 4 -TO 6' IN DEPTH FOUN DATIONBEDDING PREPARATION PRIOR TO PLACING THE BEDDING, TH E FOUNDATION MUST BE CONSTRUCTED TO A UNIFORM AND STABLE GRADE. IN THE EVENT THAT UNSUITABLE FOUN DATION MATERIALS ARE ENCOUNTERED DURING EXCAVATION, THEY SHALL BE REMOVED AND BROUGHT BACK TO THE GRADE WITH A FILL MATERIAL AS APPROVED BY THE ENGINEER. ONCE THE FOUNDATION PREPARATION IS COMPLETE, 4" - 6' OF A WELL -GRADED GRANULAR MATERIAL SHALL BE PLACED AS THE BEDDING. BACKFILL THE BACKFILL SHALL BEAN Al, A2 OR A3 GRANULAR FILL PER AASHTO M145 ORA WELL -GRADED GRANULAR FILL AS APPROVED BY THE SITE ENGINEER (SEE INSTALLATION GUIDELINES). THE MATERIAL SHALL BE PLACED IN 8' LOOSE LIFTS AN D COMPACTED TO 90% AASHTO T99 STANDARD PROCTOR DENSITY. WHEN PLACING THE FIRST LIFTS OF BACKFILL IT IS IMPORTANT TO MAKE SURE THAT THE BACKFILL IS PROPERLY COMPACTED UNDER AND AROUND THE PIPE HAUNCHES. BACKFILL SHALL BE PLACED SUCH THAT THERE IS NO MORE THAN A TWO LIFT (16') DIFFERENTIAL BETWEEN ANY OF THE PIPES AT ANY TIME DURING THE BACKFILL PROCESS. THE BACKFILL SHALL BE ADVANCED ALONG THE LENGTH OF THE DETENTION SYSTEM AT THE SAME RATE TO AVOID DIFFERENTIAL LOADING ON THE PIPE. OTHER ALTERNATE BACKFILL MATERIAL MAYBE ALLOWED DEPENDING ON SITE SPECIFIC CONDITIONS, AS APPROVED BY SITE ENGINEER. BACKFILL DETAIL NOTE I THE BE DRAWINGS ARE FOR CONCEPTUAL SCALE: N.T.S. PURPOSES AND DO NOT REFLECT ANY LOCAL i PREFERENCES OR REGULATIONS. PLEASE CONTACT YOUR LOCAL CONTECH REP FOR MODIFICATIONS. a t9 L FRONT NOTE: MANWAY DETAIL APPLICABLE FOR CMP SYSTEMS WITH DIAMETERS 48' AND PLAN LARGER. MANWAYS MAY BE REQUIRED ON SMALLER SYSTEMS DEPENDING ON TYPICAL MANWAY DETAIL ACTUAL STE SPECIFIC CONDTIONS. SCALE: N.T.S. RISER (TYP.) I'I SEE DETAIL �i I'I ii I i II ELEVATION END NOTE: TYPICAL RISER DETAIL LADDERS ARE OPTIONAL AND ARE NOT SCALE: N.T.S. REQUIRED FOR ALL SYSTEMS. 20 MIL PE IMPERMEABLE TYPICAL SECTION VIEW LINER OVER ROWS SCALE: N.T.S. NOTE: IF SALTING AGENTS FOR SNOW AND ICE REMOVAL ARE USED ON OR NEAR THE PROJECT, A GEOMEMBRAN E BARRIER IS RECOMMENDED WITH THE SYSTEM. THE GEOMEMBRANE LINER IS INTENDED TO HELP PROTECTTHE SYSTEM FROM THE POTENTIAL ADVERSE EFFECTS THAT MAY RESULT FROM A CHANGE IN THE SURROUNDING ENVIRONMENT OVER A PERIOD OF TIME. PLEASE REFER TO THE CORRUGATED METAL PIPE DETENTION DESIGN GUIDE FOR ADDITIONAL INFORMATION. TS OF )UIRED :KFILL •e�Nm " �p �\v C=:NTECHm /wte\a/�VTC�^ ,-- rte_ ---- -7981-3-0 7981-3 0 6/25n0,8 DESIGNED: DRANN'. Ins N'm'm'pm»�ao,•ea me,mew,"n�"e I/ ENGINEERED SOLUTIONS LLC _ CMP DETENTIONSYSTEMS PROJECT NAME: WCU - Central Drive Parking Lot Q z WWW.ContechES.com CIXJTECH Cullowhee, NC ' meaio-nwua»n c„nea.bn. co. 9C25Cent1e Pointe Dr.,Suite400, West Chester,OH45069 DYODS DESCRIPTION: WQV z w 800338-1122 513-645-7000 513F45-7993 FAX SHEEP NO.: 02 .,oumywm°,<Aes"o-,mlssry,r,o..paeo- mm...a»a"san"s. MARK DATE REVISION DESCRIPTION EY ORAYdNG CONTECH DETAILS W o000(D 0 LL0 LU 00- W co U to H CCOO a L� aZNN N `. zV V Z lyj 00 00 r Z OD OD J ONvO W O LU oi C4 W J 00 00 a Q z DO=OLL W OLL a a Z >. 0. 2 IY O Q z w J 04 Lf) J Q J ~ J m F- (10 ( m � =)n :2 (n m W w LLI� H Z IY O O - (n amCa7Ca". O O O 3 3 OD T N U W Z w U J cn J W m U Z IN V Z a Q z J 0W W' Q U 2 IY O Q z w J w 0 O a J J U I H Z `h IY W W o VLL z V) JJ Q a z_ O LU LU p < Q U z z � Lijo a Of V) bi DRAWN BY: CLR CDC PROJECT NO. 21731 SCO ID NO. 17-17656-01 SHEET C943 cCKConapts. PA Transmittal Date: June 27, 2018 Project Name: WCU — Central Drive Parking CDC Project: 21731 DWR ##: 20180612 To: Chonticha McDaniel NCDEQ — DWR 401 & Buffer Permitting 512 N. Salisbury Street 9th Floor Raleigh, NC 27604 Via: ® Mail ❑ Overnight ❑ Hand Delivered ❑ Pick up @ CDC Office ❑ Digital Copies -------------------- Date -------------------- Description --------------------------------------------------------------------------------------------- 1 -------------------- 06-27-2018 -------------------- Check in the amount of $505.00 --------------------------------------------------------------------------------------------- 2 -------------------- 06-27-2018 -------------------- Stormwater Management Permit Application Form (1 Original & 1 Copy) --------------------------------------------------------------------------------------------- 1 -------------------- 06-27-2018 -------------------- O&M Agreement --------------------------------------------------------------------------------------------- 1 06-27-2018 Set of Supporting Calculations 1 06-27-2018 ---------------------------- Copy of Deed 2 06-27-2018 ------------------- Sets of 2406 Stormwater Plans Remarks: C.L? ------------------------- ----------------------_-- -------- C. Landon Roberson cc: Curtis Monteith S:',ACAD'21731`docs'GR-EC-SD`21731-Transmittal-SW Submittal-2018-06-26.doex Mailing Address: P.O. Bog 5432, Asheville, NC 28813 168 Patton Avenue Asheville, NC 28801 52 Walnut Street — Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828452-4410 Fag: 828-456-5455 4643 DATE INVOICE NO COMMENT AMOUNT NETAMOUNT 06/27/2018 I it II I IIII IIII�� VIII iIIIIIU pll V SII �� I�IIIIII`II ILII II "'ll IV II 111111 21731 WCU Central Drive Parking Stormwater Permit ;; i 505.00 DATE06/27/18 VENDOR NCDEQ TOTAL 1 505.00 EVIL DESIGN CONCEPTS, PA 121 ALHM SANK ' - 168 PA'ITON AVENUE CORAL GABLES. Fi. 3373 t . ASHEVILLE, NC 28801 6341761670 828-252-5388 i F PAY Five Hundred Five and no/100 ` DAX l�fr� + IIII `; 111111,11I IoP p `L�I,n ` 9 06127ti. 8 } � - ..I d� �l: �,11i1 � I� ,, Imllllllll II I,61'111� � 1 . ,tlrvPl�u I �II�+��II •� � p SII I I � VI SII I ' E . ToTwI ��,1 liiltl��lla:- I�!�I'Ip it �V111��11;1�1�111�:u�11i� ORDER 2i 7 WE .it8111 i RALEIGH NO 2M3 � I IP6 'I�V JI ,�I�!�I I10.� ,III Illlil�'I�I III II E ull��l Ip�l�� `I II 11111 i,llli i'V�V'IlI"i °ilimlld __------ Vo Iff X6443 --I�Iltllllll;l Ul�lilll llll� pIlP;lpl ,,,IIID III II II Iii VIII. II pill II I;'111j1 "IIIIII r; IIPi II"'II VIII VIII II , a � III'IVI II1111,1111i,1 it II I IIII IIII�� VIII iIIIIIU pll V SII �� I�IIIIII`II ILII II "'ll IV II 111111 21731 WCU Central Drive Parking Stormwater Permit ;; i q il�lo III X1111 - DATE 06/27/18 VENDOR NCDEQ CHS.K CHeCK AMOUNT NIII;���'IPI � �PpIIIII�I�I Ijlllll l� _•'Vi'i dil;ll I Ili ��Ijlllj��ll�ll Ilpl I, � ,�,,II111iiilllillll lVil lll�` ._ IiPI l�llliillll;ll �j .. Ill lllllll,l !!lull' ��III'liilllnl liillillllll'I.III Ii I; iii; �Ipr.IIlQl111 ' . 1111 .Illllll II Il�lllvl _IIII II II iL � 1100046431r 1:06?0 L L?601:560.0 L68?6 L06[r 4643 DATE INVOICE NO. COMMENT AMOUNT NETAMOUNT 06/27/2018 21731 WCU Central Drive Parking Stormwater Permit 505.00 DATE 06/27/18 VENDOR NCDEQ TOTAL 505.00 [L1084P36GN] 1629255 CBZ�Pk June 27, 2018 North Carolina Dept. of Environmental Quality DWR-401 & Buffer Permitting 512 N. Salisbury Street 9' Floor Raleigh, NC 27604 Re: WCU -- Central Drive Parking CDC # 21731 DWR# 20180612 Ms. McDaniel, On behalf of Western Carolina University, we are pleased to submit a revised Stormwater Management Plan for your review and approval. Please find the responses (in red) to your "Request for Additional Information" letter dated June 6, 2018 below: 1. Please clarify whether the Division of Energy, Mineral and Land Resources will require riprap within any stream channels or wetlands as part of the Erosion & Sedimentation Control Plan approval. If riprap is required, please enumerate and clearly label the temporary and permanent impacts on the site plan and submit a channel restoration detail. Riprap must be located below the stream bed elevation. [I 5A NCAC 02H.0506(f) and (g)] We do not anticipate that riprap will be required within the stream. 2. All work must be done "in the dry". Therefore, dewatering methods will be necessary to temporarily dewater the stream channel during pipe installation. Please provide a construction sequence and dewatering detail plan to document the method of dewatering to be utilized at the site and the sequence of construction events to be followed to ensure compliance with this condition. In addition, please ensure that the locations of the temporary impacts are shown on the construction drawings and clearly indicated in the revised impact table. [I 5A NCAC 02H.0502(b)(3)] All work within the stream bed will be performed in the dry. Included with this submittal are the erosion control plans which show the required pump around system. In addition, details for the pump around system and a dewatering bag are provided. In addition, the construction sequence states that all work in the streambed will be performed in the dry. 3. A conceptual stormwater plan was provided with the application. Please provide a completed Stormwater Management Plan including all appropriate supplemental forms, O&M agreements, calculations, drawings, etc., that complies with the requirements of the State Stormwater Program. The Stormwater Design Manual and applicable forms may be found on the DEMLR's website at http://deg.nc.gov/about/divisions.'energy-mineral-land-resources/energy-mineral-land- ermit- idance/stormwater-bm -manual. Please also submit the application form SWU-101 (attached), however, the last two signature pages of this form may be omitted. The SMP package should be mailed to our 401 Stormwater Engineer, Chonticha McDaniel at the address listed Mailing Address: P.O. Boz 5432, Asheville, NC 28813 168 Patton Avenue, Asheville, NC 28801 52 Walnut Street — Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828456-5455 om� C4DCNPA below and if there are any questions regarding the SMP, please feel free to contact her directly at (919) 807-6379 or chonticha.mcdanielAncdenr.go. A completed Stormwater Management Plan including all supplemental documents and calculations are included with this submittal. We are proposing to use a proprietary system, Contech's StormFilter. DEMLR does not have a supplemental form and, based on a discussion with Ms. McDaniel, we are providing all of the design information for review. If you should have any questions or comments regarding this submittal, please do not hesitate to call. Grbg&y Hoffman, P.E. Civil Design Concepts, P.A. l c ( urt i. Mrn(ci Ili. N1( l'. '4-0 I }IJ ( uIIONN r Koad. ('u Ilya 1100 V ,-,?, ; ac;itl ' 1 %31 kit,. , er r. -ail = 1-3 1 -CM D I I L0111 ma10mc ICIM- N% ,uhmi((,il-2'111 Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue, Asheville, NC 28801 52 Walnut Street — Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-4524410 Fax: 828456-5455 DEMLR USE ONLY Date Received Fee Paid Permit Number Applicable Rules: ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ Mgmt Plan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): WCU-Central Drive Parkinv 2. Location of Project (street address): 728 Central Drive City:Cullowhee County Jackson 3. Directions to project (from nearest major intersection): Zip:28723 4. Latitude:35° 18'36" N Longitude: -830 10'48" W of the main entrance to the project. Il. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tRenewals with modifications also requires SWU-102 - Renewal Application Form b. If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known)_-------, and the status of construction: ❑Not Started []Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DEMUR requesting a state stormwater management permit appIication, list the stormwater project number, if assigned, 20180612 and the previous name of the project, if different than currently proposed, Western Carolina University Master Plan Improvements 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑LAMA Major ®Sedimentation/Erosion Control: 4.83 ac of Disturbed Area ❑NPDES Industrial Stormwater ®404/401 Permit: Proposed Impacts Stream Im act Analysis b. If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: 5. Is the project located within 5 miles of a public airport? ❑No NYes If yes, see S.L. 2012-200, Part VI: httpJlportal.ncdenr.org/web/lr/rules-and-regulations Form SWU-101 Version Oct. 31, 2013 Page 1 of 6 III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/Organization:Western Carolina University Signing Official & Title:Ioe Walker, Associate VC -Facilities Management b. Contact information for person listed in item 1a above: Street Address:3476 Old Cullowhee Road City:Cullowhee State:North Carolina Zip:28723 Mailing Address (if applicable): City: Phone: ( } Email: State: Zip: Fax: c. Please check the appropriate box. The applicant listed above is: ® The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/ Organization: Signing Official & Title: b. Contact information for person listed in item 2a above: Street Address: City:, Mailing Address (if applicable): City:_ Phone: Email: State: Zip: State: Zip: Fax: ( ) 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization:Curtis Monteith, Proiect Manager Signing Official & Title: b. Contact information for person listed in item 3a above: Mailing Address: City: Phone: Email: State: Zip: Fax: ( 4. Local jurisdiction for building permits: NCSCO Point of Contact: Phone #: Form SWU-101 Version Oct. 31, 2013 Page 2 of 6 rV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Stormwater will be captured via storm drainage pities and treated through a Contech storm filter system, and then discharged into an unnamed tributary of Cullowhee Creek. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD ❑ Valid Building Permit ❑ Other: Approval Date: Issued Date: Date: b. If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Little Tenessee River basin. 4. Total Property Area: 6.42 acres 5. Total Coastal Wetlands Area: acres 6. Total Surface Water Area: acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+:6.42 acres + Total project area shall be calculated to exclude the following: the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NHM line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (B UA). Non -coastal wetlands landward of the NHW (or MHK) Iine may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 55 % How many drainage areas does the project have?1 (For high density, count I for each proposed engineered stormwater BMP. For low density and other projects, use I for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area Drainage Area _ Drainage Area Drainage Area Receiving Stream Name UT-Cullowhee Creek Stream Class C;Tr Stream Index Number * N/A 145,033 Total Drainage Area (sf) 182,737 2,046 On-site Drains Area (sf) 176,475 Off-site Drainage Area (sf) 6,262 Proposed knpmlous Area** s 152,896 1,997 Impervious Area""total 1 87 Im rvious' Surface Area Drainage Area 1 Drainage Area _ Drainage Area Drainage Area _ On-site Buildings/ Lots (sf) On-site Streets (sf) On-site Parking (sf) 145,033 On-site Sidewalks (sf) 2,046 Other on-site (sf) Future (so Off-site (sf) 1,997 Existing BUA*** (sf) Total (sf): Stream Class and Index Number can be determined at: httV. portal.ncdenr.orgAoeb/wg/ps/csu/classifications Im ious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-101 Version Oct. 31, 2013 Page 3 of 6 *** Report only that amount of existing B UA that will remain after development. Do not report any existing B UA that is to be removed and which will be replaced by new BUA. 11. How was the off-site impervious area listed above determined? Provide documentation. Using AutoCAD software Protects in Union County: Contact DEMLR Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that may be subject to more stringent storm water requirements as per 15A NCAC 02B .05010. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded fromhgp://iRortal.ncdenr.org/web/3yg./ws/su/bMp-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from htW://portal.ncdenr.org/web/3yq/ws/s-u/statesw/forms docs. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map at hUp://portal.ncdenr.org/web/wq/ws/su/maps.) PIease indicate that the following re uired information have been grovided by initialin in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from htW://12ortal.ncdenr.oEg/web/wA/ws/su/statesw/forms docs. bels 1. Original and one copy of the Stormwater Management Permit Application Form. 6l 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants g /* Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed._ signed and dated) and O&M agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to hn://www.gaKheIR.org/Raggs/oriestoPEress.hbnl for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site Iocation. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1h mile of the site boundary, include the 1/z mile radius on the map. 7. Sealed, signed and dated calculations (one copy). 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: a. Development/ Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. Form SWU-101 Version Oct. 31, 2013 Page 4 of 6 m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off-site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"x11" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DEMLR to verify the SHVVT prior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: Page No: 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 21H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. hM://www.secrgW.state.nc.uaLCQERorations/CSearch.aspx VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from htW://portal.ncdenr.org web/lr/state-stormwater- forms docs. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional informa Consulting Engineer: fs r e4r o r ,, Consulting Mailing Ad City: . v i is 6i P44 S 1-tev df e__ Phone: g2 Email: �+ a r.kQ n �C�c ti, t y W M State: IV C— Zip: 2 Q 1 Fax. ( ) DC PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) 'certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item 1a) with (print or type name of organization Iisted in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. Form SWU-101 Version Oct. 31, 2013 Page 5 of 6 The BMP(s) on this project include (check all that apply & corresponding O&M tables will be added automatically): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:1 Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:Location(s): Quantity:0 Location(s): Present:No Location(s): Present:No Location(s): I,, a Notary Public for the State of County of , do hearby certify that personally appeared before me this day of and acknowledge the due execution of the Operations and Maintenance Agreement . Witness my hand and official seal, _____________________________________________. Maintenance records shall be kept on the following BMP(s). This maintenance record shall be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the BMP(s). Bioretention Cell Dry Detention Basin Cover Page Curtis Monteith Project Manager Facilities Management, WCU 3476 Old Cullowhee Road User Defined BMP Grassed Swale Infiltration Basin Infiltration Trench Green Roof Permeable Pavement Level Spreader/VFS I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each BMP above, and attached O&M tables. I agree to notify NCDENR of any problems with the system or prior to any changes to the system or responsible party. Phone number(s): Email: Signature: Street address: City, state, zip:Cullowhee, NC 28723 (828) 227-7442 Stormwater Wetland Wet Detention Basin Disconnected Impervious Area Proprietary System Rainwater Harvesting Sand Filter * Responsible Party: Title & Organization: Date: Operation & Maintenance Agreement Project Name: Project Location: WCU-Central Drive Parking Cullowhee, NC STORM-EZ Version 1.4 O&M Manual 6/27/2018 Page 1 of 3 Seal My commission expires STORM-EZ Version 1.4 O&M Manual 6/27/2018 Page 2 of 3 1 - - All other operation and maintenance activities should be in accordance with Contech’s StormFilter Inspection and Maintenance Procedures document. Any problems that are found shall be repaired immediately. The responsible party shall have received and understand Contech’s StormFilter Inspection and Maintenance Procedures document. Make any necessary repairs or replace if damage is too large for Outlet device Receiving water Erosion or other signs of damage have occurred at the outlet. Contact the 401 Oversight Unit at 919-733-1786. Clean out the outlet device. Dispose of the sediment offsite. The structure is damaged. Clogging has occurred. Sweep or vacuum the sediment as soon as possible. The outlet device is damaged Repair or replace the outlet device. Flow diversion structure Sediment is present on the pavement surface. The sedimentation chamber or forebay will be cleaned out whenever sediment depth exceeds six inches. The structure is clogged.Unclog the conveyance and dispose of any sediment offsite.StormFilter Cartridges BMP element: Remove the trash/debris. How many devices are Contech StormFilters? Adjacent pavement (if applicable) Potential problem:How to remediate the problem: Trash/debris is present. The drainage area will be carefully managed to reduce the sediment load to the StormFilter. Important operation and maintenance procedures: Proprietary System Maintenance Requirements Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. The StormFilter system will be inspected quarterly. Records of operation and maintenance will be kept in a known set location and will be available upon request. STORM-EZ Version 1.4 O&M Manual 6/27/2018 Page 3 of 3 11IIIIII IIIIII III Hill Illil Illll 11111 VIII VIII Il III 11111 Illll Illll IIIA IIl I III Doc ID: 005176330010 Type: WARRANT Fee RecoAmt: $996.002PageaI of 103:0'30 PM Revenue Tax: $970.00 Jackson County, NC Joe Hamilton Registerof Deeds BK21 ! ! TIG214-223 This instrument prepared by: The Law Firm of MICHELE D. SMITH Attorney at Law, P.A. Licensed North Carolina Attorneys 76 New Dawn Lane Sylva, North Carolina 28779 PREPARED WITHOUT TITLE EXAMINATION Delinquent Taxes, if any, to be paid Brief Description for the Index: by the closing attorney to the county 1.84 ac, and 0.12 ac, +l-, Cullowhee Township tax collector upon disbursement of PIN 7559-43-4025, and 7559-42-4944 the seller proceeds. Revenue $970.00 NORTH CAROLINA GENERAL WARRANTY DEED THIS DEED made this the day of December, 2016, by and between BARBARA B. DAVIS, UNMARRIED, BRADLEY C. MOSES, and wife, DANELL MOSES, GEOFF MILDENHALL, WIDOWER, ALEXANDER MILDENHALL, SINGLE, and AGATHA GUY, Ancillary Guardian of the Estate of the minor HARRISON MILDENHALL, UNMARRIED, hereinafter referred to as "Grantors", and STATE OF NORTH CAROLINA, c/o the State Property Office, 1321 Mail Service Center, Raleigh, North Carolina., 27699-1321, hereinafter referred to as "Grantee." WITNESSETH: WHEREAS, by virtue of the Last Will and Testament of Helen B. Ashe of record in Jackson County File No. 04 E 206, Grantor, Barbara B. Davis holds a 112 undivided interest in the property described in Exhibit A attached hereto, her son, Bradley C. Moses, holds a 1/4 undivided interest, and her daughter, Lisa C. Mildenhall, held a 1/4 undivided interest; and WHEREAS, Lisa C. Mildenhall passed away on February 9, 2011, in Olathe, Kansas, survived by her husband, Geoff Mildenhall, and two sons, Alexander Mildenhall and Harrison Mildenhall; and WHEREAS, a Decree of Descent issued by the Probate Court of The District Court of Johnson County, Kansas, File No. 15 PR 600, decreed that the following individuals are entitled to Lisa C. Mildenhall's 114 interest in the property conveyed herein, to wit: her husband, Geoff Mildenhall, a 112 interest of the Estate of Lisa Mildenhall (resulting in a 118 interest in the lands conveyed herein), and Alexander Mildenhall and Harrison Mildenhall, a 1/2 interest in the Estate of Lisa Mildenhall (resulting in a 1/16 interest to each of them in the lands conveyed herein); and, WHEREAS, at the time of this Decree, Harrison Mildenhall was a minor child (DOB January 24, 1999) and Petition for Appointment of Ancillary Guardian of the Estate of Harrison Mildenhall was filed in Jackson County, North Carolina, File No. 16-E-266. Attorney Agatha Guy was appointed Ancillary Guardian for the minor child, Harrison Mildenhall; and, WHEREAS, pursuant to that Order For The Sale of Real Property issued by the Honorable Ann Melton, Clerk of Superior Court, Jackson County, North Carolina, entered on October 5, 2016, and that Judge's Order of Confirmation of Private Sale issued by the Honorable Bradley B. Letts and entered November 2, 2016 in Jackson County File No. 16 -SP -46, the conveyance of the interest of the minor child, Harrison Mildenhall was approved. NOW THEREFORE, the Grantors, in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration paid by the Grantee, the receipt and sufficiency thereof is hereby acknowledged, have, and by these presents, do hereby grant, bargain, sell and convey unto the Grantee in fee simple, but subject to the exceptions, restrictions and reservations as hereinafter stated, if any, all that certain lot or parcel of land, together with road rights of way and water rights as hereinafter stated, if any, situated in Cullowhee Township, Jackson County, State of North Carolina, and more particularly described as follows: BEING AND COMPREHENDING a tract of land containing 1.84 acres, more or less, and a tract of land containing 0.12 acres, more or less being more particularly described on attached Exhibit A which is fully incorporated herein. AND BEING the same lands conveyed by deed recorded in Deed Book 498, Page 530, and being a part of the lands conveyed by deed recorded in Deed Book 234, Page 325, Jackson County Registry. All or a portion of the property herein conveyed includes, or !X does not include the primary residence of a Grantor. This conveyance is made subject to the lien for ad valorem taxes for the current year and all easements, restrictions and conditions of record and affecting said property. TO HAVE AND TO HOLD the aforesaid lot or parcel of land, together with road rights of way and water rights as hereinabove stated, if any, and all privileges and appurtenances thereto belonging to the Grantee in fee simple. AND the Grantors covenant with the Grantee that Grantors are seized of the premises in fee simple, have the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantors will warrant and defend the title against the lawful claims of all persons whomsoever, except for the water rights, exceptions, restrictions and reservations hereinabove stated, if any. [The remainder of this page intentionally left blank. Signatures and acknowledgements begin on the following page.] IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the day of December, 2016. (SEAL) BARBARA B. DAVIS by BRADLEY C. MOSES, AIF STATE OF Nert-i� C•vol'+n� COUNTY OF 7shse•• I, I,.W :1 l - -4V' Tush. r Murs..' , a Notary Public, do certify that before me personally appeared BRADLEY C. MOSES, attorney in fact for BARBARA B. DAVIS, the person(s) who signed the preceding or attached record, and being by me duly sworn, says that he executed the foregoing and annexed instrument for and in behalf of the said BARBARA B. DAVIS, and that his authority to execute and acknowledge said instrument is contained in an instrument duly executed, acknowledged, and recorded in the office of Register of Deeds in the County of Jackson, State of North Carolina, on the 15A'h day of December, 2016 in Book a I firl , Page alb , and that this instrument was executed under and by virtue of the authority given by said instrument granting him/her power of attorney. I do further certify that the said Bradley C. Moses acknowledged the due execution of the foregoing and annexed instrument for the purposes therein expressed for and on behalf of the said Barbara B. Davis. Witness my hand and official seal this 15"k day of December, 2016. WILLIAM JUSTIN MORGAN NOTARY PUBLIC NORTH CAROLINA Jackson COUNTY MY COMM. EXP. 0 1 -04-2()21 [NOTARIAL SEAL] [Must be fully legible] Notary Pub lc [Note: Notary Public must sign exactly as on notary seal] My Commission Expires: /-'f-2021 IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the 1 5* -day of December, 2016. (SEAL) BRADLEY C. MOSES STATEOF Nor -41\ Cc.Vrol:n& COUNTY OF 7&ckcor, I, , a Notary Public, do certify that before me personally appeared BRADLEY C. MOSES the person(s) who signed the preceding or attached record, and who acknowledged to me that he signed it voluntarily for its stated purpose. Witness my hand and official seal this 15�4 day of December, 2016. WILLIAM JUSTIN MORGAN NOTARY PUBLIC NORTH CAROLINA Jackson COUNTY MY CoMM, EXP. 01-04-2021 [NOTARIAL SEAL] [Must be fully legible] !c. Notary Public [Note: Notary Public must sign exactly as on notary seal] My Commission Expires: J- Lf-AO2 t IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the/!5�day of December, 2016. (SEAL) LL MOSES STATE OF Nnr+�, Corol�na COUNTY OF Nckson I, _ W;11:.w, TAO', (nor5-Y+ , a Notary Public, do certify that before me personally appeared DANELL MOSES the person(s) who signed the preceding or attached record, and who acknowledged to me that she signed it voluntarily for its stated purpose. Witness my hand and official seal this riSf"' day of December, 2016. ,_. WILLIAM JUSTIN MORGAN NOTARY PUBLIC NORTH CAROLINA Jackson COUNTY MY COMM. EXP. 01-04-202 (NOTARIAL SEAL] [Must be fully legible] Notary Public [Note: Notary Public must sign exactly as on notary seal] My Commission Expires: J- Y -,20A t IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the day of December, 2016. W&)�-C& _ -- (SEAL) GEOFF MILDENHALL STATE OF �1 n 5 COUNTY OF —,1� s �" I, v511N w4 Z , a Notary Public, do certify that before me personally appeared GEOFF MILDENHALL the person(s) who signed the preceding or attached record, and who acknowledged to me that he signed it voluntarily for its stated purpose. "'Y, Witness my hand and official seal this iq day of December, 2016. JUSTIN STAWARI Notary Public State of Kansas My Commission Expires 712 [NOTARIAL SEAL] [Must be fully legible] t N tart' Public [Note: Notary Public must sign exactly as on notary seal] My Commission Expires: z.y IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the of December, 2016. Aw..VZ*4,h&ff_(SEAL) ALEXANDER MILDENHALL STATE OF K of s c, S COUNTY OF -Au ti5 c✓) I, v 5:1"') a Notary Public, do certify that before me personally appeared ALEXANDER MILDENHALL the person(s) who signed the preceding or attached record, and who acknowledged to me that he signed it voluntarily for its stated purpose. Witness my hand and official seal this 19 day of December, 2016. l Notary Public JUSTIN STAWARI [Note: Notary Public must sign exactly as on notary scall Notary Public State of Kanat r Commission Expires - ' oZ My Commission Expires: /Z Z U 'Z u [NOTARIAL SEAL] [Must be fully legible] IN WITNESS WHEREOF, the Grantors have set their hands and seals on this the day of December, 2016. t�� (SEAL) A UY, ANCILL Y GUARDIAN of the Estate of the minor HARRISON MILDENHALL STATE OF J_4 (— COUNTY Ojjj I,�1 , a Notary Public, do certify that before me personally appeared AGATHA G , ANCILLARY GUARDIAN of The Estate of the Minor HARRISON NIILDENHALL, the person(s) who signed the preceding or attached record, and who acknowledged to me that he signed it voluntarily for its stated purpose. Witness my hand and official seal this 1��ay of December, 2016. FAMBER N. STEPHENS Notary Public North Carolina ____ Je.ckson County [NOTARIAL SEAL] [Must be fully legible] wn�?-Z� - �� V- vaus Notary Public [Note. Notary Public must sign exactly as on notary seal] { My Commission Expires: 14 0 CI) EXHIBIT A Being and comprehending Tract 1 containing 1.84 acres, more or less and Tract 2 containing 0.12 acre, more or less, both as being shown on plat entitled "Plat of Survey for State of North Carolina", dated April 2015 and recorded in Plat Cabinet 21 at Slide 447 of the Jackson County Public Registry. Subject to the terms and conditions of a Deed of Easement and Right of Way with Tuckaseigee Water & Sewer Authority, dated January 23, 2006 and recorded in Book 1568 at Page 127 of the Jackson County Public Registry. Rights of way further shown on plats recorded in Plat Cabinet 14 at Slides 646 and 647 of the Jackson County Public Registry. Right of way of North Carolina State Road 1169 (Central Drive) to its full legal width. Rights of way as shown on plat recorded in Plat Cabinet 21 at Slide 447 of the Jackson County Public Registry. Rights of way to Nantahaia Power and Light Company as recorded in Book 258 at Page 258 and Book 249 at Page 125, both of the Jackson County Public Registry. Utility easements further shown on the above referenced and recorded plat. Being the same lands and premises as described in Book 498 at Page 530 and Book 234 at Page 325, both of the Jackson County Public Registry. Reference is also made to the Estate of Helen B. Ashe as filed in 04 E 206 of the Office of the Clerk of Court for Jackson County. Roy Robert Ashe died in Jackson County on November 25, 1971. SCR'S „ k{received UC? 21 ZU14 1 _:.010 Revenue S 312.00 THIS INSTRUMENT PREPARED By R. S. Jones, Jr. a licensed North Carolina Attorney. Delinquent taxes, if any, to be paid by the closing attorney to the county tax collector upon disbursement of closing proceeds. This property is not the primary residence of seller. Please return recorded document to R. S. Jones, Jr., 61 East Main Street Franklin, NC 28734 Tax ID # 7559-42-3836; 7559-42-0794; 7559-42-0967 NORTH CAROLINA JACKSON COUNTY Doc ID: 004811940003 Type: GRP Recorded: 10/21/2014 at 04:10:40 Ph Fee Amt: $338.00 Page 1 of 3 Revenue Tax: $312.00 Jackson County, NC Joe Hamilton Register of Deeds BK2053PG269-271 WARRANTY DEED THIS DEED, Made this the 22nd day of August, 2014 by and between FRANCIS M. WEBSTER and wife JENABEL F. WEBSTER whose mailing address is 9150 E. Center Avenue, Apt 9C, Denver, CO 80247 parties of the first part to THE STATE OF NORTH CAROLINA whose mailing address is % State Property Office 1321 Mail Service Center, Raleigh, NC 27699-1321 party of the second part, whether one or more; the neuter gender shall be deemed to include the masculine and feminine and the singular number the plural, and vice versa; WITNESSETH, That the said parties of the first part in consideration of Ten Dollars and other valuable consideration, the receipt of which is hereby acknowledged, have bargained and sold and by these presents do bargain, sell and convey unto said party of the second part, and its successors and assigns, that certain tract or parcel of land being in Cullowhee Township, Jackson County, State ofNorth Carolina, being more particularly described as follows: First Tract: All of Parcel #7559-42-3836. That certain tractor parcel of land lying and being in Cullowhee Township, Jackson County, North Carolina, and being described by metes and bounds as follows: Being and comprehending all of Lot Number Five (5), all of Lot Number Six (6), all of Lot Number Seven (7), all of Lot Number Eight (8), and all of Lot Number Nine (9) of the Subdivision of the Bryson land near Cullowhee School, as will appear on map or plat of said Subdivision made by W. D. Wike, Surveyor, on the 29`s day ofMay,1926, which said plat or map is duly recorded in the office of the Register of Deeds for Jackson County, North Carolina, in Map Book 1, page 80, to which said map and record reference is hereby made for a more full and complete description of said lands. Second Tract: Being all of Parcel #7559-42-0794. That certain tract of parcel of land lying and being in Cullowhee Township, Jackson County, North Carolina, and being described as follows: Being and comprehending all of Lot Number Ten (10), all of Lot Number Eleven (11), all of Lot Twelve (12), all of Lot Thirteen (13), all of Lot Fourteen (14) and all of Lot Fifteen (15) of the Subdivision of the Bryson land near Cullowhee School, as will appear on map or plat of said Subdivision made by W. D. Wike, Surveyor, on the 29`° day of May, 1926, which said plat or map is duly recorded in the office of the Register of Deeds for Jackson County, North Carolina, in Map Boole 1, page 80, to which said reap and record reference is hereby made for a more full and complete description of said lands. Less and except the lands described in the deed from Logan Taylor, et ux, to Bertie Rogers dated September 3, 1948, recorded in Book 294 at page 593, Jackson County Public Records, and being described as follows: BEGINNING at a stake, a corner common to Lots 15 and 16 of the Bryson Subdivision, runs thence North 14 degrees West 10 feet to a point; thence South 80 degrees 30 minutes West 117 feet to a stake; thence South 14 degrees East 10 feet to a stake in the line of Lot 16; thence North 80 degrees 30 minutes East to the point of Beginning. Third Tract: All of Parcel #7559-42-0967. That certain tract or parcel of land lying and being in Cullowhee Township, Jackson County, North Carolina, and being described by metes and bounds as follows: BEGINNING at a stake on the bank of the road and in Henry Bryson's line and runs thence, S. 43 W. 150 feet to a stake in the line of the lands formerly owned by Henry Bryson, et al, thence S. 4 E 58 feet to a stake; thence N. 76 E. 165 feet to a stake on the bank of the road; thence N. 19W. 135 feet to the Beginning, containing one-half (% ) acre. TO HAVE AND TO HOLD the aforesaid tracts or parcels of land and all privileges and appurtenances thereunto belonging, or in anywise thereupon appertaining, unto the said party of the second part, its successors and assigns, to its only use and behoof, in fee simple forever, subject to those exceptions, reservations and limitations following the description hereinabove set forth. And the said parties of the first part covenant with said party of the second part, its successors and assigns, that they are seized of said premises in fee, and have the right to convey the same in fee simple; that the same free and clear from all liens and encumbrances and that they will warrant and defend the said title to the same against the lawful claims of all persons whatsoever, subject to those exceptions, reservations and limitations following the description hereinabove set forth. IN TESTIMONY WHEREOF, the said parties of the first pant have hereunto set their hands and seal, the day and year first above written. _(SEAL) Francis ebste (SEAL) na a F. ebster STATE OF o i d COUNTY OF ea ele �n I, J " 1 airi d A 'a zo\ a Notary Public of the aforesaid County and State hereby certify that Francis iVL Webster and wife Jenabel Webster, personally appeared before me this day and acknowledged the due execution of the foregoing instrument for the purposes therein expressed. WITNESS my hand and Notarial seal, this the aiji� day of a 2014. Notary Public I My Commission Expires: w_W (NOTARIAL SEAL) NAM L MEZA NOTARY PUBLIC 11TATE Of COLORADO NOMARY n 'at 34040 4s W OMMOMEWW:x,.r t.2V ti C"k1tOLINA .1 -)'+ COUNTY ... - ► 14TI i ,E) to ME CORREC'. �i)I f)f:I DS 11II11III�I�I llf Ilf f1IIIII IIIIIIIf f f IIIf I If f f f IIIII IIIIIIIIIIIIIIIIIIIIIIIIILII Doc 1D: 003046780003 Type: CRR Recorded: 01/23/2004 at 11:23:01 AM Fee Amt: $182.00 Page 1 of 3 Excise Tax: $162.00 Jackson County, NC Joe Hamilton Repister of Deeds BK1437 PG403-405 NORTH CAROLINA GENERAL WARRANTY DEED Mail after Recording to: T. Michael Jordan, 154 N, Main St., Suite 1, Waynesville, NC 28786 This instrument prepared by: T. Michael Jordan Excise Tax: $162.00 Parcel Identifier No. 7559-42-4744 3 ?n" THIS DEED made this 23rd day of July, 2004, by and between - GRANTOR JOHN R, ADAMS and wife, SHELBY J. ADAMS GRANTEE STATE OF NORTH CAROLINA c/o State Property Office 1321 Mail Service Center Raleigh, NC 27699-1321 The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and shall include singular, plural, masculine, feminine or neuter as required by context. WITNESSETH, that the Grantor, for a valuable consideration paid by the Grantee, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee in fee simple, all that certain lot or parcel of land situated in Cullowhee Township, Jackson County, North Carolina, and more particularly described as follows: SEE SCHEDULE A ATTACHED HERETO AND INCORPORATED HEREIN BY REFERENCE. The property hereinabove described was acquired by Grantor by instrument recorded in Book 614, Page 492. TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple. And the Grantor covenants with the Grantee, that Grantor is seized of the premises in fee simple, has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever except for the exceptions hereinafter stated. Title to the property hereinabove described is subject to the following exceptions. SEE SCHEDULE A ATTACHED HERETO AND INCORPORATED HEREIN BY REFERENCE. IN WITNESS WHEREOF, the Grantor has hereunto set his hand and seal the day and year first above written. (SEAL) AMS (SEAL) SHELB J. XDAMS STATE OF NORTH CAROLINA COUNTY OF HAYWOOD I, a Notary Public of the County and State aforesaid, certify that JOHN R. ADAMS and SHELBY J. ADAMS, Grantor, personally appeared before me this day and acknowledged the execution of the foregoing instrument. Witness my hand and official stamp or seal, this 23rd day of July, 2004. My commission expires: ���*� ct%ae� Joy. -O 01120!2008 :,� v� �.0 Notary Public #OTA# : 40 ,f,,o0 C11111��� ,,,,,, % SCHEDULE A According to a plat of survey by Joel Johnson Land Surveying, R. Joel Johnson, PLS, dated May 22, 2003, and from said plat of survey being more particularly described as follows: Beginning on a PK nail found in the centerline of N. C. S. R. 1169, being a corner of Ashe (Deed Book 238, page 475), said PK nail bearing S. 29 deg. 13 min. 45 sec. E. 2,048.06 feet from NGS "Breese" and also bearing S. 09 deg. 58 min. 25 see. W. 51.89 feet from a PK nail found in the centerline of said public road; thence continuing with the centerline of said public road runs S. 09 deg. 11 min. 45 sec. W. 103.25 feet to a PK nail found in the centerline of said public road, being a corner of Stonehouse Assoc. (Deed Book 1038, page 408); thence runs N. 80 deg. 03 min. 45 sec. W. 232.76 feet to a point in a creek; thence N. 06 deg. 10 min. 15 sec. E. 72.63 feet to a point in said creek; thence S. 87 deg. 28 min. 55 sec. E 238.19 feet to the point of Beginning, containing 0.47 acres, more or less. For source of title reference is hereby made to Book 614, page 492, Jackson County Registry. This conveyance is made subject to the right of way of North Carolina State Road 1169. ;u EC I; F Z2 Drafted by: MICHELE D. SMITH Attorney & Counselor at Law 76 New Dawn Lane P.O. Box 1905 Sylva, North Carolina 28779 111111111 I III IIIII IIIII I III I Iffll I IIII IIIII IIIII IIIII IIIII IIII IIII Doc ID: 004573050006 Tvpe: CRP Recorded: 12/21/2012 at 11:25:53 AM Fee Amt: $612.00 Page 1 of 6 Revenue Tax: $586.00 Jackson County, NC Joe Hamilton Register of Deeds BK 1968 PG! 1-1 6 �SESSOR_ \ �PReceived Oma, DEC 20 2 //n THIS INSTRUMENT PREPARED WITHOUT TITLE EXAMINATION Brief Description for index: Cullowhee Township PIN# 755942-3668 PIN # 7559-42-4547 Revenue S 586.00 NORTH CAROLINA GENERAL WARRANTY DEED THIS DEED made this the j I day of December, 2012, by and between, STONEHOUSE ASSOCIATES, LLC, a North Carolina Limited Liability Company, of P.O. Box 1002, Sylva, NC 28779; (hereinafter referred to as Grantor), and STATE OF NORTH CAROLINA, of c/o State Property Office, 1321 Mail Service Center, Raleigh, NC 27699-1321 (hereinafter referred to as Grantee). The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors and assigns, and shall include the singular, plural, masculine, feminine or neuter as required by context. WITNESSETH The Grantor, for good and valuable consideration paid by Grantee, the receipt of which is hereby acknowledged, has, and by these presents does grant, bargain, sell and convey unto Grantee in fee simple, all of that certain lot or parcel of land situated in Cullowhee Township, Jackson County, North Carolina, and more particularly described as follows: BEING AND COMPREHENDING two parcels of land and being more particularly described on attached Exhibit A which is fully incorporated herein. AND BEING the same lands conveyed unto Stonehouse Associates, a North Carolina General Partnership, by deeds recorded in Deed Book 1038, Page 408; and Deed Book 1112, Page 266, Jackson County Registry. All or a portion of the property herein conveyed includes, or X does not include the primary residence of a Grantor. This conveyance is made subject to the lien for ad valorem taxes for the current year and all easements, restrictions and conditions of record and affecting said property. TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple. And the Grantor covenants with the Grantee, that Grantor is seized of the premises in fee simple, has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever except for the exceptions noted herein. (the remainder of this page intentionally left blank and signatures begin on following page) IN WITNESS WHEREOF, the Grantor has hereunto set their hand and seal the day and year first written above. STONEHOUSE ASSOCIATES, LLC A North Carolina Limited Liability Company By://� 14,/4 6", 14 , (SEAL) THOMAS HART GOODSON, J ., Manager STATE OF NORTH CAROLINA COUNTY OF JACKSON 1, C t6ta Notary Public of the State and Coun a earing above, certify that befo e me personaby ap eared THOMAS HART GOODSON, JR. ersonally know me _, r who proved to me by satisfactory evidence { ) to be the persons) whose name is signed on the preceding or attached record, and acknowledged to me that he signed it voluntarily for its stated purpose, that he is Manager of Stonehouse Associates, LLC, a North Carolina limited liability company, and that by authority duly given and as the act of the limited liability company, he executed the foregoing instrument. Witness my hand and official seal this T S• � 4. ' �% .�pAY . # 42 Q t U3 10 ©� ' •.w � 0 [N `' ARIA. EA: „e.fully legibl of December, 2012. ublic [Note: Notary Public must sign exactly as on notary seal) ' My Commission Expires: IN WITNESS WHEREOF, the Grantor has hereunto set their hand and seal the day and year first written above. STONEHOUSE ASSOCIATES, LLC A North. Carolina Limited Liability Company By:6 LC l D (SEAL) ROBERT POTTS, Manager STATE OF NORTH CAROLINA COUNTY OF JACKSON I, Q U , n � � , a Notary Public of the Sr and County appearing above, certify that before me personally appefred ROBERT POTT ersonally known to me or who proved to me by satisfactory evidence ( ) to be ose name is signed on the preceding or attached record, and acknowledged to me that he signed it voluntarily for its stated purpose, that he is Manager of Stonehouse Associates, LLC, a North Carolina limited liability- company, and that by authority duly given and as the act of the limited liability company, he executed the foregoing instrument. Witness my hand and official seal this c� r #ay of December, 2012. d LY ►''�� A R Y� P U V F AR 1ESEAL] {Must be fully legible] Public [Note Notary Public must sign exactly as on notary seal] My Commission Expires: t�?2- Qe aC17 EXHIBIT A GENERAL WARRANTY DEED STONEHOUSE ASSOCIATES, LLC A NORTH CAROLINA LIMITED LIABILITY COMPANY TO STATE OF NORTH CAROLINA TRACT ONE: BEING AND COMPREHENDING all of Lot # Three (3), and all of Lot # Four (4), of the subdivision of the Bryson Land near Cullowhee School, as will appear on map or plat of said subdivision made by W.D. Wike, surveyor on the 29th day of May, 1926, which said plat or map is duly recorded in the Office of the Register of Deeds for Jackson County, North Carolina, in Map Book 1, Page 80, to which said map and record reference is hereby made for a more full and complete description of said lands. Being the same lands as conveyed and described by deed dated February 16, 2001 from Jeanne Buchanan Campbell and husband, Dean J. Campbell, to Stonehouse Associates, a General Partnership, recorded in Book 1112, Page 266, Jackson County Public Registry. This instrument is made and given SUBJECT TO a sewer easement conveyed to Tuckasegee Water and Sewer Authority, recorded in Book 1568, Page 119, Jackson County Public Registry. TRACT TWO: BEING AND COMPREHENDING all of Tract 1, containing 0.81 acres, and all of Tract 2, containing 0.29 of an acre, as shown on a map or plat prepared by John W. Jurss, RLS, dated March 22, 1999, entitled "StoneHouse Associates", and being Lots 1 & 2, and Lots 42 through 48 (incorrectly stated as Lots 42 through 47 on the plat) of the Bryson Subdivision, which said plat or map is duly recorded in the Office of the Register of Deeds for Jackson County in Plat Cabinet 9, Slide 602, to which said map and recorded reference is hereby made for a more full and complete description of said lands. Being the same lands as conveyed and described by deed dated March 25, 1999 from Conrad L. Hooper and wife, Anna Lee Hooper, to Stonehouse Associates, a North Carolina General Partnership, recorded in Book 1038, Page 408, Jackson County Public Registry. This instrument is made and given SUBJECT TO the right of way for NCSR #1168, Ed Norton Road; and for NCSR #1169, Dicks Gap Road, to their full legal widths. This instrument is made and given SUBJECT TO a water line easement conveyed to Dix Gap Water Improvement Project, recorded in Book 645, Page 25, Jackson County Public Registry. This instrument is made and given SUBJECT TO easements for water and sewer services as conveyed to Tuckasegee Water and Sewer Authority recorded in Book 1070, Page 88; Book 1568, Page 111; and Book 1568, Page 115, Jackson County Public Registry. WCU - CENTRAL DRIVE PARKING STORM DRAINAGE CALCULATIONS PREPARED FOR: WESTERN CAROLINA UNIVERSITY 3476 OLD CULLOWHEE ROAD CULLOWHEE, NORTH CAROLINA 28723 CURTIS MONTIETH (828) 227-7442 \ttt51111f1J1!l��� Y o 0 e SEAL _ a g '35093 g inpx i#Ap� mmvuA f!Olrlfll ftmwwqF pwmX CMN CDCc,,,,,,P, wnfrl+Iffa.R Me a xof�auf�euf�e aa+e+ .n.�.MNdwl�osn.�pr...s� �.�uci i. JOB NO. 21731 WCU-CENTRAL DRIVE PARKING CDC Project No.: 21731 Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue Asheville, NC 28801 52 Walnut Street – Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828-456-5455 TABLE OF CONTENTS 1. Stormwater Narrative 2. Impervious Calculations 3. Drainage Runoff Summary 4. Drainage Area Maps I. Pre-Development II. Post-Development III. Storm Structure 5. Water Quality Volume Worksheet 6. Contech Design Data 7. Stormwater Control Measures I. StormFilter HydroCAD Report 8. Pipe Network Calculations I. 25 Year Event 9. Culvert Calculations I. Stream Culvert – Line D 10. Pipe Outlet Protection I. Rip Rap Apron A 11. Permanent Ditch Calculations I. Permanent Ditch A II. Permanent Ditch B 12. NRCS Soil Report 13. Geotechnical Exploration Report 14. Figures I. USGS Topo Map II. FEMA FIRMette Map III. NOAA Precipitation Tables Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue, Asheville, NC 28801 52 Walnut Street – Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828-456-5455 Project Name: WCU - CENTRAL DRIVE PARKING Project Location: Western Carolina University, Central Drive CDC Project No. 21731 Date: June 27, 2018 PROJECT NARRATIVE General The proposed Central Drive Parking encompass approximately an area of 8.1 acres, 5.6 acres of which is disturbed. The project area currently consists of recently graded open area. The affected area is located on Central Drive, just south of Merlite Court. The proposed plan will involve the construction of a 419 space parking lot and 2 retaining walls. Storm Drainage Stormwater will be collected at storm drainage structures on site. These structures will route stormwater runoff to an underground StormFilter system. The stormwater will eventually be discharged in to an unnamed tributary of Cullowhee Creek. Landscaping is proposed which will provide shading to reduce runoff temperature. Runoff from the first inch of rainfall will be directed through and treated by the StormFilter system. The internal bulkhead will be set at 6’ to capture the first flush. Additional runoff will overtop the bulkhead, bypassing treatment. The outlet control structure is designed to maintain the existing conditions flow rate of the 25-year, 24-hour storm event. After reviewing and evaluating the downstream water course, we do not anticipate any negative downstream impacts due to the stormwater discharge from the site. WCU-CENTRAL DRIVE PARKING CDC Project No.: 21731 Pre-Development Post Development (SF)(SF) Grass, Woods 269,341 132,576 Total Pervious:269,341 132,576 Gravel 4,630 0 Asphalt/Parking 3,465 145,033 Sidewalks 0 2,046 Building 2,219 0 Total Impervious:10,314 147,079 % Impervious:3.7%52.6% Total Area:279,655 279,655 ONSITE PROPERTY Area Type IMPERVIOUS CALCULATIONS Issued 6/21/2018 WCU - Central Drive Parking CDC Project No.: 21731 25-year Pre-Development 17.60 Post-Development - Unrouted 28.81 Post Development - Routed 16.96 Requirements (Outfall < Pre)PASS Note: Information calculated using HydroCAD software. Drainage Runoff Summary Storm Event (CFS) StormFilter Runoff Condition Issued 6/27/2018 \ YET W�pq N In A f0 O N z '^+ m F amD V LLI N \ / z N j N N N z V V Z N W \ O J CO mo=o GD I.L. NW0 \ \ u oo a IL z z a a 3 \ \ \ U � r a a -ee e.� 34011- D ,elty - V eook 2, P., 704 Detl B PIN 559- 7143-3182 }!1 W a \ Dead 3— 545, Page 421 PIN 7559-43-1131 �Z O II)1111�—��� � lit III)1,11111It \vwwpvv 1 ,- VAIVAAA \\gVAAA�1� :k \ V I I �IIIAI�y�A v� Av\V I y- VA�AAA\V�AAA� J= VAVV\UI IA \ I I�1111 VAA V�VA` vvv� vv \� \ V A �1IIII1II IIII�IIIII �� n SJR V IAM I III \ VA V A V v i 1 � IAAI `VA�VA11 IAVA I1VIvvV 1� �_ - VA � \ \VAA\� V AI \V IIIIIII�jIIIlIll1� IIII Iv � v i � / � / \ AVAIII m I j�`VAA 1111I1I�\�A� VAA\V VA 111 I IA \vl \VAA\� A 1 I \ I IIII II IIIIIIIIIII I(I I\\II 1 IIIIIII I I 11 ��V 1 V 1 1 1 1 1! II III 11j111���1�� \\\ i \IO �\V e� do AI A VIVI IIVPI �wvV`�\1 A�-cA l l v-- O/ \VlVAIAI1�Avv�v\1llVAVi \ V n \v�Vv ��VAAVAA\�A bH 1 I V v O( / y ai z W VA P N 23 1452 \ \\\ \�\� \ \\\\ \n \\ ((( 7559 \ It I IIII IIIIII III \ I I I ` 4 q \\\\\�\\II�IIIIII \\ N II IIII„IIIbv I J W m P;�ww\`;vv\vv�v ` j IIIIIIC'�1II1'11�11°gull z I�w�,it V''0v\ �....I' f o� �I vVAAIIIII�IIIIIII `V -111 Ajj�\IN\VA 0vvv11111VA AVA`\ V��VVAAII I� �lllllll�llllll A vv �� v` v1111v,�vvv� ��v , / : �.1�5VAI00 ��I1A�VA` I }` , 3 v ;NII I VAv\0 VA�v�AA01 /I 7D VA I� 1 jV AAVAVA \� II1v N I I �lgUdJ �� v v vv A A A I p�c�tu V y 1tl 1ul v r 111 I lull�p,l � Ivvn�v vv vI vv �l 1111'11"II� / ua�e A �_ � \ (7) III � v vvv� ull I li 111 qV A\ v A vim, p III I v ' h )11 \ II 1111 111111IIIIII 111IIIIII \ / /y b \\\\\\\\`\\\\\I\I\ III III I(/ 1 1 II pI II1 '� IIII III \ \\ \ \ \ \ \ \ \ill1111 111 I 1 \ L / /V 1p,llha� \\ 1ij�1111i 4.52A— _ y Deetl Book 2053 Page 269 Deed Book 1437 Poge 493 �/�ee411 413 d Book 2177. Poge 214 AAAA\, / \\ \ I III IIII \'.. ,I I;I,,I� 111 0l�llll IIIIII \ \ 11\I III I 1 pull \ \ i De2d Book 1968, Page Ji PIN J119 42 '59_42-3.8 59 42 3668 PIN 7559-42-18555 II II IIIIIIII I l \ III I v v PRE—CONSTRUCTION �14v l u I�I�p�ll DRAINAGE AREA PIN755924025 PIN 7559 42 4944 PIN 7559-42-4744 uI�1111��II111111iiiil �l�ll1111 I I I IA`VA�V 1 °i �1ih ilii�Uil�Ihl�o4lg1�1j11 l v o I II I (I u 1 vIv v v 4.34 AC a lu ll, IIII IIII1111111111111j1 A /IIIIfl11l V�I �11VAVA� y�hll�Illl � IIII II /j111111�/A / I I �\��AVA. � � vv IIII 111111111 _�� e.ow� III IIVIIII�III> A III IIIIIIIIII A1/ II ///i I Iv A Deed Book 76. Page 74e 1111j11111jlllppllllll I J II 11 f 111 :,,�I I 111 \\\ \\\. I / I f11 Ij 11111 2 III I1 II \\III IN7559 32-8461 111 III II)I\\\I`II\I I�\\\ \\\\�\\ \\\ I1pI�II�IIII�011llllllllllll 111 II�I�IIIIII���IIIIII�III�IIII�� IIII�illi IIlit / /�VI\iI1�111� �1111111 \�\\\ \�1 v� I I 1111111j111ill I� v — I II v III A V s IIII h11 h v IIII II11�iiilN//IIII C_ _ )Illl)llllllllll- VIIII �V I{ III' IIII I1111IIj11hII�IIjI� v �, j� III III i�l\ II V A A AAVA v !!1!�lflrfllll(I`\\\ 11111 I III/111\\\\ \ \ IIIIII III 1111111111111111\ \ / �� gu ��, Z IIII III 1 /��1111II�11111IVAA\V� VAvv ` 1 11111V11(I , 1 , -� v�VAVA� A I II V�IVI 1 �1111�1111�1111�1i11II11 v� �� \\\\ I III J \ G 11 IIII111111111A\l v IVAA v I AAVA� �I I II I �}II hhG �\ IV 11 j1V1V�Avv��v \ VA AA i �v IIII 1 �V 1 \° A I a I I \ I j J J M \\ \\\\-,IIIII \� I`\ \ \ \ \ I VQ �VA�VAVAO� vvv ' , �1IA v BItI A v�vAV A vOvv v \,>////II v vA�A\ V A I �I"11111111 A Av 1, ��`�vvvv � //v�vvvvvv`vvv vv v v\vv IIv 111 1'1111 11111111;;1 vv -,�1, v 0] w _ 11 \ \\\\\\\M,\\\II IIIIIIIII1jIIIIIIIII \ 77 A.- I Jill I 11I11111111 111j111�III \ Z 1 \ \' \ \ \\\III IIII Deed BNaok Page 269 III111 X11 I \ / \ I I1I 1 W PI7559-42-1855 1 \ \ ` \ 111111 1 � / I II IIIIIII1l1_ I I I 1111111111\ \\`� �_�-� � � (7 Q 1111 �11� 111111 I 111 IIII`\� - �\ III III II \;= `\ \\ I \ \\ \\\\ \\ \\\� 1 , v v vIIIvv v v v v 111,1111 I vv �-, / v z Q 11 1 W a 1i � 111, 11 V IVI�vv� v v�v Z O � r v�j111v�A 1v� \ I bel\L` 1 Pwv C) Of 1 W C) 0 50 100 200 Of U W Deetl Bo011E, Poge '60 Brymn - PIN 7559-42-4323 Deetl Book 13E, Poge 305 N 7559-42-1512 ` z O Q PIN 7559-42-1661 \ \ 1 inch = 100 ft. � � Q \ YET W�pq N I n 01 2 O N Z '^+ m F mV LLI N�C� \ / a 2N N N V V V Z j N N W \ O J CO GD I.L. mo=o NW0 \ \ u oo a Y IL z a a 3 o U /^� r ee em c-1— UI, ny — 2, Pa 704 714}3182 N c Oe.d ook �� \ PINB 559- W a }!1 •_ e(L) „ —d P 545, Page 421 PIN 7559-43-1131 \ i!'/ - �_ \ ' Z O 3 O d U 3 �\\nIV� `8 0 -)CO CN \N\\11\\\1 O� ]2 N �_ y III( u I� I j\11A11A1 IIII �� \VA�AA1A111��A���� A �W — OII y LUU P N 7559-23-1452 �\ V 14 fin' -j J PERMANENT DITCH B—�` DRAINAGE AREA / 0.36 ACl�'1 `ti ° 111v/ V �v �1v ' i ° Ili1 u1� �t� ff li�` m z \ ch R mT N NNN l !, 4.52 aces269 Oo_ I I I 1 I \ \ . _ r 111111111 1111 11111( 21� l \�� \IIIIN111\ \ II / IIII 1 III \ • / r i VIII _ — T �},�, - - Ili �y _ \ D -d Book 2053 Page 403 DeeE Book 143J Page 403 O De2tl Q0 -f / II II \ t],� �" ■ �- 1\ I\1I 1 II111111111 II \\`11�\11111�II,lllll111 I III I \�\\ T ��� v 1 STORMFILTER i b Book2-8, P—27 PIN )559 42 -"" PIN 7559-42-3. PIN 7559-42-18585 PERMANENT DITCH A u11j1 I°IIII 111 y I IIIIIIIIIII IIII VIII IIIIII 1111 IIII\\\ --_ \ \ \ \ i `� \ V -- � IIII IIIIIIIIIIIIIIIIIIII IIIIIII � 1 ') 1 I II ��}l\ 1 \ \ \— �. � DRAINAGE AREA 1 Flu IIII IIII IIIIII v �ai IIi 4.20 AC 7227 5/ IIIIIII�llllllllllpll�llllll v (� 1 III \ \ � I I L�� II � II 111 �I \ SII IIIIII IIII Illlllll �1 � � 1 IV �pj11111h1 IIIIIIIiII \ i I 1 \ 1 (IIIIIII PIN 7559-43-4D25 PIN 7559-42-4944 PIN 7559-42-4744 _ DRAINAGE AREA P a Book 1176, Pae 746 -d 1111 IIIIIIIIIIIIIIIIIIII � A � IIII I IIV nI111111 v • IIII \ IIIIIIIIIII 111 11111111�1j11 li 111111/1 III\\\��\ 1V ■ � .i 6, �IIIIIhI1uI411IiylIIPIIuIlI11I` , ��p IY ` 2.22 AC _ `� ,, q 1v1 � I/1 I � /�1j11�111jII�I�l1Il11p�pII�Ij�I11111 3��� �I1A \ , I I � � I I IIII II 11 I �� Ir -�-� 1�Ild)I11�IIIIll1111 r�41 tl4�ll II Iqi� �" 5 Z nlrlrlilr111nlIIvvv __j �w��o°,11 IT '� 11I��� p LLJ 1 CAVA � � A = " I I IIS II� � it 1 l IIII k A53 I55 yA> 1A I y� �� Dead Paok 205}�uJ �' � F— PN75-42--ll. � � Z 2 ��' I ,v�21220 Q wQ 10 O r CwS4't I\\N I I XI 0 50 100 200 (n w l oePI a eke9-481,E, Peg 1 yeN _ N 7552-432.3 Deetl B.-21,31-4 Poge 305 N 7559-42-1512 0 O 0 U PIN 7559-42-1861 1 1inch = 100 ft. I- Q o N\eQ \ O o O z m N � m v W N N a 2 N N N Z V V a\ 0 j N J CO a�izw�~tow N W j N N GD W J 0`D IM N W pp20LL 0LL F zaa a3 3 V \� aPN'S..9e�3 � a \ a _ Wa5_ \ Deed Book 544 5, 421 \ \ +'' PIN 7559-0.3-11311131 y/ DoT /� I - C O N ii C n _^/N> Co C\j 22B2 N EX2 1\ V I�3 w u I i iI1p 83 0) B3 a o \I we��em cer9 - �I�VII� \... Deaf Bo427 Page 399 \ \ \ \ \\ ��� 1.42 C. _ , / PIN 7Z'9-21-1412 \ N \\ � �___ 86 v NI�i vvvvvliilllllll�� B7 I` I � ■,� yy v/ �- 5,� \ F �✓ / / ■ B4 / v B5 0 � A3 v' ti ■ III ��LU _ �.� � u* N LU �� 01 na,J � ■ y �[�V A2 rah z I"„h LU IM v \\II\I II I NN NN IIII NNNN ��IIIIItl ■ F � 7rae1 A Z ��VI�II�����IIIIIII� Q Q f 41I VIVhJu dypp a�I I IF �\\\\`\\�\�11I,���\��1�1III / � 11�� � L�\ ■ / 1, I � � I � p IIII `II111I r / ` I B7 Al O I I II I I �2 ■ � N �� N VI v��� ���iii 1.03 AC. I�1I IIII�IIII 4 / _ ry 452 Acres g_ oeatl Book 2053 Page 269 Boak 1440 Deed Boak 1437 Poge 214 37 Po �y - \ Ooeed Book ztn Page 214 /gyp ed 1 C P Baok 1960 4547 7 z a J559 4 4 P N J559 42 3668 42 1e55 - PIN 00 III �I1 IIIIII ; 759 025 11 N'S59 42-4944 ':N -4 42 4744 _ �III����I�I�II III���� I�II�I�IIII IIID1 I 1 Jill il�4li jlulll MVI \ I I �pph�ipgllliuillilil \ i 10InI �/9 / ■ B5 b a IV a `° p II -Brea °����II�I�I��IIp�pI�IIII�>i, p �, I � IIIIII D-d Book 1176. Pa9a 746 „ PIN 7659 32-8461 IIIIIII I I1 I11 ` III I � I1I''\ ��, B6 / 0.90 AC. I III,IIII VIII 2_ 0.88 AC. r, fr Pg X21 „�%�l„ / ■ �� lTl ��I�III��, �Ivv�v��vI p v�v vvvvv�vv��Avv�� '�. �� 1 ts� / y t r t �� II�� J ,req B I o of 1.77 o, � m Deed PIN 712'19"42`4' oS 2z ■ 'I f w J A 1 223Y ---- 2 I m 3 v 1 2\_N v w Q \\ w � 1 W a I I I��am 69 3 w P 55942 1512 \ PIN J359-42-1661 ' L 0 50 100 200 U � U C) \ (n � O C_ 0_ 1 inch = 100 ft. o Q ou WCU-CENTRAL DRIVE PARKING CDC Project No.: 21731 3.65 acres 1,850 sf 3.51 acres Rv = 0.05 + 0.9(IA) 1 inches 12130 cu ft DV = 3630 * RD * RV * A Pipes 0 ft (including header rows) 0 ft 0 ft 2 139 ft 50.27 sq ft 13975 cu ft 8385 cu ft [(L * W * H *) - PV] * 40% + PV 13069 cu ft From HydroCAD Report Notes: One acre = 43,560 square feet WATER QUALITY CALCULATIONS BASIN INFORMATION WATER QUALITY VOLUME Drainage Area (A) 96.2% 0.92 StormFilterSCM ID Impervious Area Percent Impervious (IA) Run-off coefficent (RV) UNDERGROUND DETENTION Gravel Bed Width (W) Pipe Cross Section Area Design Storm Depth (RD) Design Volume Required (DV) Underground detention system consists of: Volume provided (V) Pipe Length Gravel Bed Length (L) Pipe Volume (PV) SCM CONFIGURATION Gravel Bed Height (H) Total Calculated Volume Pipe Rows Issued 6/27/2018 Date:6/25/18 Project Name:WCU - Central Drive Parking Lot City / County:Cullowhee State:NC Designed By:Rahn Sutton Company:Contech =Adjustable Input Cells Telephone:(919) 889-0878 Out-to-out length (ft):139.0 Backfill Porosity (%):0% System Diameter (in):96 Out-to-out width (ft):19.0 Depth Above Pipe (in):0.0 Pipe Spacing (in):36 Number of Manifolds (ea):1.0 Depth Below Pipe (in):0.0 Incremental Analysis (in):2 Number of Barrels (ea):2.0 Width At Ends (ft):2.0 System Invert (Elevation):0 Width At Sides (ft):2.0 Depth (ft)Elevation (ft)Incremental Storage (cf) Cumulative Storage (cf) Incremental Storage (cf) Cumulative Storage (cf) Incremental Storage (cf) Cumulative Storage (cf) Percent Open Storage (%) Ave. Surface Area (sf) 0.00 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0%0.0 0.17 0.16 71.7 71.7 0.0 0.0 71.7 71.7 100.0%642.1 0.33 0.33 129.7 201.4 0.0 0.0 129.7 201.4 100.0%898.4 0.50 0.50 166.2 367.6 0.0 0.0 166.2 367.6 100.0%1,088.3 0.67 0.66 194.6 562.2 0.0 0.0 194.6 562.2 100.0%1,242.6 0.83 0.83 218.3 780.5 0.0 0.0 218.3 780.5 100.0%1,373.4 1.00 1.00 238.6 1,019.0 0.0 0.0 238.6 1,019.0 100.0%1,486.9 1.17 1.16 256.3 1,275.4 0.0 0.0 256.3 1,275.4 100.0%1,586.8 1.33 1.33 272.0 1,547.4 0.0 0.0 272.0 1,547.4 100.0%1,675.6 1.50 1.50 286.0 1,833.4 0.0 0.0 286.0 1,833.4 100.0%1,754.8 1.67 1.66 298.5 2,131.9 0.0 0.0 298.5 2,131.9 100.0%1,825.9 1.83 1.83 309.7 2,441.6 0.0 0.0 309.7 2,441.6 100.0%1,889.7 2.00 2.00 319.8 2,761.4 0.0 0.0 319.8 2,761.4 100.0%1,946.8 2.17 2.16 328.8 3,090.2 0.0 0.0 328.8 3,090.2 100.0%1,998.0 2.33 2.33 336.9 3,427.1 0.0 0.0 336.9 3,427.1 100.0%2,043.6 2.50 2.50 344.0 3,771.1 0.0 0.0 344.0 3,771.1 100.0%2,084.0 2.67 2.66 350.3 4,121.4 0.0 0.0 350.3 4,121.4 100.0%2,119.4 2.83 2.83 355.9 4,477.3 0.0 0.0 355.9 4,477.3 100.0%2,150.3 3.00 3.00 360.6 4,837.9 0.0 0.0 360.6 4,837.9 100.0%2,176.6 3.17 3.16 364.7 5,202.6 0.0 0.0 364.7 5,202.6 100.0%2,198.7 3.33 3.33 368.0 5,570.6 0.0 0.0 368.0 5,570.6 100.0%2,216.6 3.50 3.50 370.6 5,941.2 0.0 0.0 370.6 5,941.2 100.0%2,230.4 3.67 3.66 372.6 6,313.8 0.0 0.0 372.6 6,313.8 100.0%2,240.2 3.83 3.83 373.9 6,687.7 0.0 0.0 373.9 6,687.7 100.0%2,246.0 4.00 4.00 374.6 7,062.3 0.0 0.0 374.6 7,062.3 100.0%2,248.0 4.17 4.16 374.6 7,436.9 0.0 0.0 374.6 7,436.9 100.0%2,246.0 4.33 4.33 373.9 7,810.8 0.0 0.0 373.9 7,810.8 100.0%2,240.2 4.50 4.50 372.6 8,183.4 0.0 0.0 372.6 8,183.4 100.0%2,230.4 4.67 4.66 370.6 8,554.0 0.0 0.0 370.6 8,554.0 100.0%2,216.6 4.83 4.83 368.0 8,922.0 0.0 0.0 368.0 8,922.0 100.0%2,198.7 5.00 5.00 364.7 9,286.7 0.0 0.0 364.7 9,286.7 100.0%2,176.6 5.17 5.16 360.6 9,647.3 0.0 0.0 360.6 9,647.3 100.0%2,150.3 5.33 5.33 355.9 10,003.2 0.0 0.0 355.9 10,003.2 100.0%2,119.4 5.50 5.50 350.3 10,353.5 0.0 0.0 350.3 10,353.5 100.0%2,084.0 5.67 5.66 344.0 10,697.5 0.0 0.0 344.0 10,697.5 100.0%2,043.6 5.83 5.83 336.9 11,034.4 0.0 0.0 336.9 11,034.4 100.0%1,998.0 6.00 6.00 328.8 11,363.2 0.0 0.0 328.8 11,363.2 100.0%1,946.8 6.17 6.16 319.8 11,683.0 0.0 0.0 319.8 11,683.0 100.0%1,889.7 Pipe Stone Total SystemSystem Storage Volume Estimation Miscellaneous Contech Engineered Solutions, LLC is pleased to offer the following estimate of storage volume for the above named project. The results are submitted as an estimate only, without liability on the part of Contech Engineered Solutions, LLC for accuracy or suitability to any particular applicaton and are subject to verification of the Engineer of Record. This tool is only applicable for rectangular shaped systems. CMP: Underground Detention System Storage Volume Estimation Summary of Inputs Pipe & Analysis InformationSystem Information Backfill Information These results are submitted to you as a guideline only, without liability on the part of CONTECH Engineered Solutions, LLC for accuracy or suitability to any particular application, and are subject to your verification. 6.33 6.33 309.7 11,992.7 0.0 0.0 309.7 11,992.7 100.0%1,825.9 6.50 6.50 298.5 12,291.2 0.0 0.0 298.5 12,291.2 100.0%1,754.8 6.67 6.66 286.0 12,577.2 0.0 0.0 286.0 12,577.2 100.0%1,675.6 6.83 6.83 272.0 12,849.2 0.0 0.0 272.0 12,849.2 100.0%1,586.8 7.00 7.00 256.3 13,105.6 0.0 0.0 256.3 13,105.6 100.0%1,486.9 7.17 7.16 238.6 13,344.1 0.0 0.0 238.6 13,344.1 100.0%1,373.4 7.33 7.33 218.3 13,562.4 0.0 0.0 218.3 13,562.4 100.0%1,242.6 7.50 7.50 194.6 13,757.0 0.0 0.0 194.6 13,757.0 100.0%1,088.3 7.67 7.66 166.2 13,923.2 0.0 0.0 166.2 13,923.2 100.0%898.4 7.83 7.83 129.7 14,052.9 0.0 0.0 129.7 14,052.9 100.0%642.1 8.00 8.00 71.7 14,124.6 0.0 0.0 71.7 14,124.6 100.0%0.0 These results are submitted to you as a guideline only, without liability on the part of CONTECH Engineered Solutions, LLC for accuracy or suitability to any particular application, and are subject to your verification. 1S Proposed Conditions 3S Bypass 5S PRE DEV 2P Underground Storage 4L Combined Proposed Routing Diagram for 21731 - Contech - rev Prepared by {enter your company name here}, Printed 6/21/2018 HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Subcat Reach Pond Link 21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 2HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Area Listing (all nodes) Area (sq-ft) CN Description (subcatchment-numbers) 189,050 68 1 acre lots, 20% imp, HSG B (5S) 30,056 69 50-75% Grass cover, Fair, HSG B (3S) 6,098 61 >75% Grass cover, Good, HSG B (1S) 152,896 98 Paved parking, HSG B (1S) 378,101 80 TOTAL AREA 21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 3HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Soil Listing (all nodes) Area (sq-ft) Soil Group Subcatchment Numbers 0 HSG A 378,101 HSG B 1S, 3S, 5S 0 HSG C 0 HSG D 0 Other 378,101 TOTAL AREA 21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 4HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Ground Covers (all nodes) HSG-A (sq-ft) HSG-B (sq-ft) HSG-C (sq-ft) HSG-D (sq-ft) Other (sq-ft) Total (sq-ft) Ground Cover Sub Num 0 189,050000189,050 1 acre lots, 20% imp 0 30,056 0 0 0 30,056 50-75% Grass cover, Fair 0 6,098 0 0 0 6,098 >75% Grass cover, Good 0 152,896000152,896 Paved parking 0 378,101 0 0 0 378,101 TOTAL AREA Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 5HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Time span=1.00-24.00 hrs, dt=0.05 hrs, 461 points Runoff by SCS TR-20 method, UH=SCS, Weighted-CN Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=3.650 ac Runoff Depth>5.15"Subcatchment 1S: Proposed Conditions Flow Length=1,554' Tc=5.0 min CN=97 Runoff=28.81 cfs 68,265 cf Runoff Area=0.690 ac Runoff Depth>2.33"Subcatchment 3S: Bypass Tc=5.0 min CN=69 Runoff=2.91 cfs 5,844 cf Runoff Area=4.340 ac Runoff Depth>2.25"Subcatchment 5S: PRE DEV Tc=5.0 min CN=68 Runoff=17.60 cfs 35,420 cf Peak Elev=6.91' Storage=10,952 cf Inflow=28.81 cfs 68,265 cfPond 2P: Underground Storage Outflow=14.82 cfs 68,256 cf Inflow=16.96 cfs 74,101 cfLink 4L: Combined Proposed Primary=16.96 cfs 74,101 cf Total Runoff Area = 378,101 sf Runoff Volume = 109,530 cf Average Runoff Depth = 3.48" Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 6HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Subcatchment 1S: Proposed Conditions Runoff = 28.81 cfs @ 11.95 hrs, Volume= 68,265 cf, Depth> 5.15" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs Type II 24-hr 25-year Rainfall=5.51" Area (ac) CN Description 3.510 98 Paved parking, HSG B 0.140 61 >75% Grass cover, Good, HSG B 3.650 97 Weighted Average Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 1,554 5.18 Direct Entry, Subcatchment 1S: Proposed Conditions Runoff Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Type II 24-hr 25-year Rainfall=5.51" Runoff Area=3.650 ac Runoff Volume=68,265 cf Runoff Depth>5.15" Flow Length=1,554' Tc=5.0 min CN=97 28.81 cfs Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 7HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Subcatchment 3S: Bypass Runoff = 2.91 cfs @ 11.96 hrs, Volume= 5,844 cf, Depth> 2.33" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs Type II 24-hr 25-year Rainfall=5.51" Area (ac) CN Description 0.690 69 50-75% Grass cover, Fair, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 3S: Bypass Runoff Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)3 2 1 0 Type II 24-hr 25-year Rainfall=5.51" Runoff Area=0.690 ac Runoff Volume=5,844 cf Runoff Depth>2.33" Tc=5.0 min CN=69 2.91 cfs Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 8HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Subcatchment 5S: PRE DEV Runoff = 17.60 cfs @ 11.96 hrs, Volume= 35,420 cf, Depth> 2.25" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs Type II 24-hr 25-year Rainfall=5.51" Area (ac) CN Description 4.340 68 1 acre lots, 20% imp, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 5S: PRE DEV Runoff Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Type II 24-hr 25-year Rainfall=5.51" Runoff Area=4.340 ac Runoff Volume=35,420 cf Runoff Depth>2.25" Tc=5.0 min CN=68 17.60 cfs Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 9HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Pond 2P: Underground Storage Inflow Area = 158,994 sf, Inflow Depth > 5.15" for 25-year event Inflow = 28.81 cfs @ 11.95 hrs, Volume= 68,265 cf Outflow = 14.82 cfs @ 12.05 hrs, Volume= 68,256 cf, Atten= 49%, Lag= 5.8 min Primary = 14.82 cfs @ 12.05 hrs, Volume= 68,256 cf Routing by Stor-Ind method, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs / 3 Peak Elev= 6.91' @ 12.05 hrs Surf.Area= 1,698 sf Storage= 10,952 cf Plug-Flow detention time= 4.1 min calculated for 68,108 cf (100% of inflow) Center-of-Mass det. time= 4.0 min ( 752.5 - 748.5 ) Volume Invert Avail.Storage Storage Description #1 0.00' 13,069 cf 96.0" Round CMP_Round 96" L= 260.0' S= 0.0050 '/' Device Routing Invert Outlet Devices #1 Primary 0.00'15.0" Vert. Orifice/Grate C= 0.600 #2 Primary 7.00'8.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=14.78 cfs @ 12.05 hrs HW=6.88' (Free Discharge) 1=Orifice/Grate (Orifice Controls 14.78 cfs @ 12.04 fps) 2=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs) Pond 2P: Underground Storage Inflow Primary Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Inflow Area=158,994 sf Peak Elev=6.91' Storage=10,952 cf 28.81 cfs 14.82 cfs Type II 24-hr 25-year Rainfall=5.51"21731 - Contech - rev Printed 6/21/2018Prepared by {enter your company name here} Page 10HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Link 4L: Combined Proposed Inflow Area = 189,050 sf, Inflow Depth > 4.70" for 25-year event Inflow = 16.96 cfs @ 12.01 hrs, Volume= 74,101 cf Primary = 16.96 cfs @ 12.01 hrs, Volume= 74,101 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs Link 4L: Combined Proposed Inflow Primary Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Inflow Area=189,050 sf 16.96 cfs16.96 cfs Hydraflow Storm Sewers Extension for Autodesk® AutoCAD® Civil 3D® Plan Project File: 2018-06-21 Storm Drainage.stm tfall10 Number of lines: 9 1 Date: 6/21/2018 Storm Sewers 02.00 CDCStorm Page 1 Line Line Invert Invert Line Line Line n-val Inlet Gnd/Rim Hw Drng Inlet Runoff i Incr Flow Vel Capac No. ID Up Dn Size Length Slope Pipe ID EI Up Area Time Coeff Inlet Q Rate Dn Full (ft) (ft) (in) (ft) M (ft) (ft) (ac) (min) (C) (in/hr) (cfs) (cfs) (ft/s) (cfs) 1 131-62 2206.71 2206.68 30 3.344 0.90 0.012 B2 2216.95 3.14 0.01 5.0 0.92 7.65 0.07 28.32 9.20 42.10 2 B2 -B3 2206.92 2206.71 30 21.483 1.00 0.012 B3 2216.17 3.41 1.42 5.0 0.89 7.65 9.64 28.25 5.76 44.41 3 B3 -B4 2208.69 2207.42 24 126.722 1.00 0.012 B4 2218.36 2.42 0.01 5.0 0.92 7.65 0.07 18.61 5.92 24.53 4 B4 -B5 2209.68 2208.69 24 98.469 1.00 0.012 B5 2216.68 2.40 0.90 5.0 0.89 7.65 6.11 18.54 5.90 24.50 5 B5 -B6 2210.55 2209.68 24 87.295 1.00 0.012 B6 2215.12 2.00 0.88 5.0 0.89 7.65 5.95 12.43 3.96 24.50 6 136-137 2211.60 2211.30 15 30.096 1.00 0.012 B7 2215.64 1.78 1.03 5.0 0.82 7.65 6.48 6.48 5.28 7.00 7 Al -A2 2206.54 2192.40 30 108.399 13.05 0.012 A2 2219.17 1.99 0.00 5.0 0.00 0.00 0.00 14.82 20.40 160.47 8 A2 -A3 2206.69 2206.54 30 14.500 1.00 0.012 A3 2219.91 1.99 0.00 5.0 0.00 0.00 0.00 14.82 3.53 44.43 9 A3 -A4 2206.70 2206.69 30 1.365 0.73 0.012 A4 2219.81 1.99 0.00 5.0 0.00 0.00 14.82 14.82 3.54 38.04 Project File: 2018-06-21 Storm Drainage.stm Number of lines: 9 Date: 6/21/2018 NOTES: Intensity = 61.63 / (Inlet time + 11.30) " 0.75 -- Return period = 25 Yrs. ; i Inlet control; ** Critical depth Storm Sewers 5S Stream Culvert Routing Diagram for 21731 - HydroCAD - Stream Culvert-Line D Prepared by {enter your company name here}, Printed 6/21/2018 HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Subcat Reach Pond Link 21731 - HydroCAD - Stream Culvert-Line D Printed 6/21/2018Prepared by {enter your company name here} Page 2HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Area Listing (all nodes) Area (sq-ft) CN Description (subcatchment-numbers) 257,309 68 1 acre lots, 20% imp, HSG B (5S) 653,400 60 Woods, Fair, HSG B (5S) 620,686 76 Woods/grass comb., Fair, HSG C (5S) 1,531,395 68 TOTAL AREA 21731 - HydroCAD - Stream Culvert-Line D Printed 6/21/2018Prepared by {enter your company name here} Page 3HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Soil Listing (all nodes) Area (sq-ft) Soil Group Subcatchment Numbers 0 HSG A 910,709 HSG B 5S 620,686 HSG C 5S 0 HSG D 0 Other 1,531,395 TOTAL AREA 21731 - HydroCAD - Stream Culvert-Line D Printed 6/21/2018Prepared by {enter your company name here} Page 4HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Ground Covers (all nodes) HSG-A (sq-ft) HSG-B (sq-ft) HSG-C (sq-ft) HSG-D (sq-ft) Other (sq-ft) Total (sq-ft) Ground Cover Subc Num 0 257,309000257,309 1 acre lots, 20% imp 0 653,400000653,400 Woods, Fair 0 0 620,686 0 0 620,686 Woods/grass comb., Fair 0 910,709 620,686 0 0 1,531,395 TOTAL AREA Type II 24-hr 25-year Rainfall=5.51"21731 - HydroCAD - Stream Culvert-Line D Printed 6/21/2018Prepared by {enter your company name here} Page 5HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Time span=1.00-24.00 hrs, dt=0.05 hrs, 461 points Runoff by SCS TR-20 method, UH=SCS, Weighted-CN Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=35.156 ac Runoff Depth>2.24"Subcatchment 5S: Stream Culvert Flow Length=1,553' Tc=22.3 min CN=68 Runoff=80.69 cfs 285,369 cf Total Runoff Area = 1,531,395 sf Runoff Volume = 285,369 cf Average Runoff Depth = 2.24" Type II 24-hr 25-year Rainfall=5.51"21731 - HydroCAD - Stream Culvert-Line D Printed 6/21/2018Prepared by {enter your company name here} Page 6HydroCAD® 10.00-12 s/n 04679 © 2014 HydroCAD Software Solutions LLC Summary for Subcatchment 5S: Stream Culvert Runoff = 80.69 cfs @ 12.16 hrs, Volume= 285,369 cf, Depth> 2.24" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 1.00-24.00 hrs, dt= 0.05 hrs Type II 24-hr 25-year Rainfall=5.51" Area (ac) CN Description 15.000 60 Woods, Fair, HSG B 14.249 76 Woods/grass comb., Fair, HSG C 5.907 68 1 acre lots, 20% imp, HSG B 35.156 68 Weighted Average Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 14.8 100 0.2000 0.11 Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.22" 5.5 873 0.2790 2.64 Shallow Concentrated Flow, Woodland Kv= 5.0 fps 2.0 580 0.1017 4.78 Shallow Concentrated Flow, Grassed Waterway Kv= 15.0 fps 22.3 1,553 Total Subcatchment 5S: Stream Culvert Runoff Hydrograph Time (hours) 242322212019181716151413121110987654321Flow (cfs)90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Type II 24-hr 25-year Rainfall=5.51" Runoff Area=35.156 ac Runoff Volume=285,369 cf Runoff Depth>2.24" Flow Length=1,553' Tc=22.3 min CN=68 80.69 cfs Culvert Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Thursday, Jun 21 2018 Stream Culvert - Line D Invert Elev Dn (ft) = 2188.00 Pipe Length (ft) = 442.00 Slope (%) = 3.85 Invert Elev Up (ft) = 2205.00 Rise (in) = 48.0 Shape = Circular Span (in) = 48.0 No. Barrels = 1 n-Value = 0.013 Culvert Type = Circular Culvert Culvert Entrance = Smooth tapered inlet throat Coeff. K,M,c,Y,k = 0.534, 0.555, 0.0196, 0.9, 0.2 Embankment Top Elevation (ft) = 2210.00 Top Width (ft) = 0.00 Crest Width (ft) = 1.00 Calculations Qmin (cfs) = 80.69 Qmax (cfs) = 80.69 Tailwater Elev (ft) = (dc+D)/2 Highlighted Qtotal (cfs) = 80.69 Qpipe (cfs) = 80.69 Qovertop (cfs) = 0.00 Veloc Dn (ft/s) = 7.16 Veloc Up (ft/s) = 8.87 HGL Dn (ft) = 2191.36 HGL Up (ft) = 2207.72 Hw Elev (ft) = 2209.08 Hw/D (ft) = 1.02 Flow Regime = Inlet Control 0.0 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 550.0 600.0 650.0 Elev (ft)Hw Depth (ft)Profile 2184.00 -21.00 2188.00 -17.00 2192.00 -13.00 2196.00 -9.00 2200.00 -5.00 2204.00 -1.00 2208.00 3.00 2212.00 7.00 Reach (ft) Embankment 442.00 Lf of 48(in) @ 3.85 % Hw HGL Appendices Rev. 12/93 8.06.3 Hydrology Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Thursday, Jun 21 2018 Permanent Ditch A Hydrograph type = Rational Peak discharge (cfs) = 6.286 Storm frequency (yrs) = 25 Time interval (min) = 1 Drainage area (ac) = 2.220 Runoff coeff. (C) = 0.37 Rainfall Inten (in/hr) = 7.653 Tc by User (min) = 5 IDF Curve = WCU.IDF Rec limb factor = 1.00 Hydrograph Volume = 1,886 (cuft); 0.043 (acft) 0 5 10 Q (cfs) 0.00 0.00 1.00 1.00 2.00 2.00 3.00 3.00 4.00 4.00 5.00 5.00 6.00 6.00 7.00 7.00 Q (cfs) Time (min) Runoff Hydrograph 25-yr frequency Runoff Hyd - Qp = 6.29 (cfs) Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Thursday, Jun 21 2018 Permanent Ditch A Triangular Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 1.00 Invert Elev (ft) = 2232.00 Slope (%) = 6.60 N-Value = 0.030 Calculations Compute by: Known Q Known Q (cfs) = 6.29 Highlighted Depth (ft) = 0.73 Q (cfs) = 6.290 Area (sqft) = 1.07 Velocity (ft/s) = 5.90 Wetted Perim (ft) = 3.26 Crit Depth, Yc (ft) = 0.91 Top Width (ft) = 2.92 EGL (ft) = 1.27 0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 Elev (ft)Depth (ft)Section 2231.50 -0.50 2232.00 0.00 2232.50 0.50 2233.00 1.00 2233.50 1.50 2234.00 2.00 Reach (ft) North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v6.0 CHANNEL ANALYSIS > > > Permanent Ditch A Name Permanent Ditch A Discharge 6.29 Peak Flow Period 24 Channel Slope 0.066 Channel Bottom Width 0 Left Side Slope 2 Right Side Slope 2 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Bunch Type Vegetation Density Good 75-95% Soil Type None SC250 - Class C - Bunch Type - Good 75-95% SC250 Unvegetated Straight 6.29 cfs 5.36 ft/s 0.77 ft 0.035 2.5 lbs/ft2 3.15 lbs/ft2 0.79 UNSTABLE E SC250 Reinforced Vegetation Straight 6.29 cfs 3.1 ft/s 1.01 ft 0.072 8 lbs/ft2 4.15 lbs/ft2 1.93 STABLE E Underlying Substrate Straight 6.29 cfs 3.1 ft/s 1.01 ft -- 0.8 lbs/ft2 0.36 lbs/ft2 2.22 STABLE -- Phase Reach Discharge Velocity Normal Depth Mannings N Permissable Shear Stress Calculated Shear Stress Safety Factor Remarks Staple Pattern ECMDS 6.0 https://ecmds.com/project/136679/channel-analysis/144601/show 1 of 1 6/21/2018, 8:40 AM Hydrology Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Thursday, Jun 21 2018 Permanent Ditch B Hydrograph type = Rational Peak discharge (cfs) = 1.019 Storm frequency (yrs) = 25 Time interval (min) = 1 Drainage area (ac) = 0.360 Runoff coeff. (C) = 0.37 Rainfall Inten (in/hr) = 7.653 Tc by User (min) = 5 IDF Curve = WCU.IDF Rec limb factor = 1.00 Hydrograph Volume = 306 (cuft); 0.007 (acft) 0 5 10 Q (cfs) 0.00 0.00 1.00 1.00 2.00 2.00 Q (cfs) Time (min) Runoff Hydrograph 25-yr frequency Runoff Hyd - Qp = 1.02 (cfs) Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Thursday, Jun 21 2018 Permanent Ditch B Triangular Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 1.00 Invert Elev (ft) = 2240.00 Slope (%) = 10.20 N-Value = 0.030 Calculations Compute by: Known Q Known Q (cfs) = 1.02 Highlighted Depth (ft) = 0.34 Q (cfs) = 1.020 Area (sqft) = 0.23 Velocity (ft/s) = 4.41 Wetted Perim (ft) = 1.52 Crit Depth, Yc (ft) = 0.44 Top Width (ft) = 1.36 EGL (ft) = 0.64 0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 Elev (ft)Depth (ft)Section 2239.50 -0.50 2240.00 0.00 2240.50 0.50 2241.00 1.00 2241.50 1.50 2242.00 2.00 Reach (ft) North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v6.0 CHANNEL ANALYSIS > > > Permanent Ditch B Name Permanent Ditch B Discharge 1.02 Peak Flow Period 24 Channel Slope 0.102 Channel Bottom Width 0 Left Side Slope 2 Right Side Slope 2 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Bunch Type Vegetation Density Good 75-95% Soil Type None SC250 - Class C - Bunch Type - Good 75-95% SC250 Unvegetated Straight 1.02 cfs 3.61 ft/s 0.38 ft 0.04 2.5 lbs/ft2 2.39 lbs/ft2 1.05 STABLE E SC250 Reinforced Vegetation Straight 1.02 cfs 1.48 ft/s 0.59 ft 0.132 8 lbs/ft2 3.74 lbs/ft2 2.14 STABLE E Underlying Substrate Straight 1.02 cfs 1.48 ft/s 0.59 ft -- 0.8 lbs/ft2 0.16 lbs/ft2 5.08 STABLE -- Phase Reach Discharge Velocity Normal Depth Mannings N Permissable Shear Stress Calculated Shear Stress Safety Factor Remarks Staple Pattern ECMDS 6.0 https://ecmds.com/project/136679/channel-analysis/144602/show 1 of 1 6/21/2018, 8:42 AM United States Department of Agriculture A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for Jackson County, North CarolinaNatural Resources Conservation Service June 6, 2018 Preface Soil surveys contain information that affects land use planning in survey areas. They highlight soil limitations that affect various land uses and provide information about the properties of the soils in the survey areas. Soil surveys are designed for many different users, including farmers, ranchers, foresters, agronomists, urban planners, community officials, engineers, developers, builders, and home buyers. Also, conservationists, teachers, students, and specialists in recreation, waste disposal, and pollution control can use the surveys to help them understand, protect, or enhance the environment. Various land use regulations of Federal, State, and local governments may impose special restrictions on land use or land treatment. Soil surveys identify soil properties that are used in making various land use or land treatment decisions. The information is intended to help the land users identify and reduce the effects of soil limitations on various land uses. The landowner or user is responsible for identifying and complying with existing laws and regulations. Although soil survey information can be used for general farm, local, and wider area planning, onsite investigation is needed to supplement this information in some cases. Examples include soil quality assessments (http://www.nrcs.usda.gov/wps/ portal/nrcs/main/soils/health/) and certain conservation and engineering applications. For more detailed information, contact your local USDA Service Center (https://offices.sc.egov.usda.gov/locator/app?agency=nrcs) or your NRCS State Soil Scientist (http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/contactus/? cid=nrcs142p2_053951). Great differences in soil properties can occur within short distances. Some soils are seasonally wet or subject to flooding. Some are too unstable to be used as a foundation for buildings or roads. Clayey or wet soils are poorly suited to use as septic tank absorption fields. A high water table makes a soil poorly suited to basements or underground installations. The National Cooperative Soil Survey is a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local agencies. The Natural Resources Conservation Service (NRCS) has leadership for the Federal part of the National Cooperative Soil Survey. Information about soils is updated periodically. Updated information is available through the NRCS Web Soil Survey, the site for official soil survey information. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or a part of an individual's income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require 2 alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA's TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write to USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410 or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer. 3 Contents Preface....................................................................................................................2 How Soil Surveys Are Made..................................................................................5 Soil Map..................................................................................................................8 Soil Map................................................................................................................9 Legend................................................................................................................10 Map Unit Legend................................................................................................11 Map Unit Descriptions.........................................................................................11 Jackson County, North Carolina.....................................................................13 BrC—Braddock-Urban land complex, 2 to 15 percent slopes,....................13 CrD—Cowee-Evard-Urban land complex, 15 to 30 percent slopes............15 EvE—Evard-Cowee complex, 30 to 50 percent slopes...............................16 References............................................................................................................20 4 How Soil Surveys Are Made Soil surveys are made to provide information about the soils and miscellaneous areas in a specific area. They include a description of the soils and miscellaneous areas and their location on the landscape and tables that show soil properties and limitations affecting various uses. Soil scientists observed the steepness, length, and shape of the slopes; the general pattern of drainage; the kinds of crops and native plants; and the kinds of bedrock. They observed and described many soil profiles. A soil profile is the sequence of natural layers, or horizons, in a soil. The profile extends from the surface down into the unconsolidated material in which the soil formed or from the surface down to bedrock. The unconsolidated material is devoid of roots and other living organisms and has not been changed by other biological activity. Currently, soils are mapped according to the boundaries of major land resource areas (MLRAs). MLRAs are geographically associated land resource units that share common characteristics related to physiography, geology, climate, water resources, soils, biological resources, and land uses (USDA, 2006). Soil survey areas typically consist of parts of one or more MLRA. The soils and miscellaneous areas in a survey area occur in an orderly pattern that is related to the geology, landforms, relief, climate, and natural vegetation of the area. Each kind of soil and miscellaneous area is associated with a particular kind of landform or with a segment of the landform. By observing the soils and miscellaneous areas in the survey area and relating their position to specific segments of the landform, a soil scientist develops a concept, or model, of how they were formed. Thus, during mapping, this model enables the soil scientist to predict with a considerable degree of accuracy the kind of soil or miscellaneous area at a specific location on the landscape. Commonly, individual soils on the landscape merge into one another as their characteristics gradually change. To construct an accurate soil map, however, soil scientists must determine the boundaries between the soils. They can observe only a limited number of soil profiles. Nevertheless, these observations, supplemented by an understanding of the soil-vegetation-landscape relationship, are sufficient to verify predictions of the kinds of soil in an area and to determine the boundaries. Soil scientists recorded the characteristics of the soil profiles that they studied. They noted soil color, texture, size and shape of soil aggregates, kind and amount of rock fragments, distribution of plant roots, reaction, and other features that enable them to identify soils. After describing the soils in the survey area and determining their properties, the soil scientists assigned the soils to taxonomic classes (units). Taxonomic classes are concepts. Each taxonomic class has a set of soil characteristics with precisely defined limits. The classes are used as a basis for comparison to classify soils systematically. Soil taxonomy, the system of taxonomic classification used in the United States, is based mainly on the kind and character of soil properties and the arrangement of horizons within the profile. After the soil 5 scientists classified and named the soils in the survey area, they compared the individual soils with similar soils in the same taxonomic class in other areas so that they could confirm data and assemble additional data based on experience and research. The objective of soil mapping is not to delineate pure map unit components; the objective is to separate the landscape into landforms or landform segments that have similar use and management requirements. Each map unit is defined by a unique combination of soil components and/or miscellaneous areas in predictable proportions. Some components may be highly contrasting to the other components of the map unit. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The delineation of such landforms and landform segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, onsite investigation is needed to define and locate the soils and miscellaneous areas. Soil scientists make many field observations in the process of producing a soil map. The frequency of observation is dependent upon several factors, including scale of mapping, intensity of mapping, design of map units, complexity of the landscape, and experience of the soil scientist. Observations are made to test and refine the soil-landscape model and predictions and to verify the classification of the soils at specific locations. Once the soil-landscape model is refined, a significantly smaller number of measurements of individual soil properties are made and recorded. These measurements may include field measurements, such as those for color, depth to bedrock, and texture, and laboratory measurements, such as those for content of sand, silt, clay, salt, and other components. Properties of each soil typically vary from one point to another across the landscape. Observations for map unit components are aggregated to develop ranges of characteristics for the components. The aggregated values are presented. Direct measurements do not exist for every property presented for every map unit component. Values for some properties are estimated from combinations of other properties. While a soil survey is in progress, samples of some of the soils in the area generally are collected for laboratory analyses and for engineering tests. Soil scientists interpret the data from these analyses and tests as well as the field-observed characteristics and the soil properties to determine the expected behavior of the soils under different uses. Interpretations for all of the soils are field tested through observation of the soils in different uses and under different levels of management. Some interpretations are modified to fit local conditions, and some new interpretations are developed to meet local needs. Data are assembled from other sources, such as research information, production records, and field experience of specialists. For example, data on crop yields under defined levels of management are assembled from farm records and from field or plot experiments on the same kinds of soil. Predictions about soil behavior are based not only on soil properties but also on such variables as climate and biological activity. Soil conditions are predictable over long periods of time, but they are not predictable from year to year. For example, soil scientists can predict with a fairly high degree of accuracy that a given soil will have a high water table within certain depths in most years, but they cannot predict that a high water table will always be at a specific level in the soil on a specific date. After soil scientists located and identified the significant natural bodies of soil in the survey area, they drew the boundaries of these bodies on aerial photographs and Custom Soil Resource Report 6 identified each as a specific map unit. Aerial photographs show trees, buildings, fields, roads, and rivers, all of which help in locating boundaries accurately. Custom Soil Resource Report 7 Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 8 9 Custom Soil Resource Report Soil Map 3909140390918039092203909260390930039093403909380390914039091803909220390926039093003909340301900 301940 301980 302020 302060 302100 302140 302180 302220 302260 301900 301940 301980 302020 302060 302100 302140 302180 302220 302260 35° 18' 28'' N 83° 10' 44'' W35° 18' 28'' N83° 10' 29'' W35° 18' 20'' N 83° 10' 44'' W35° 18' 20'' N 83° 10' 29'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,760 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:12,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Jackson County, North Carolina Survey Area Data: Version 13, Sep 26, 2017 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Feb 6, 2016—Oct 26, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Custom Soil Resource Report 10 Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI BrC Braddock-Urban land complex, 2 to 15 percent slopes, 1.2 16.6% CrD Cowee-Evard-Urban land complex, 15 to 30 percent slopes 4.8 66.2% EvE Evard-Cowee complex, 30 to 50 percent slopes 1.2 17.2% Totals for Area of Interest 7.2 100.0% Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or Custom Soil Resource Report 11 landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, onsite investigation is needed to define and locate the soils and miscellaneous areas. An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha-Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha-Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. Custom Soil Resource Report 12 Jackson County, North Carolina BrC—Braddock-Urban land complex, 2 to 15 percent slopes, Map Unit Setting National map unit symbol: lc72 Elevation: 1,730 to 2,250 feet Mean annual precipitation: 50 to 58 inches Mean annual air temperature: 46 to 57 degrees F Frost-free period: 116 to 170 days Farmland classification: Not prime farmland Map Unit Composition Braddock, moderately eroded, and similar soils: 50 percent Urban land: 30 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Braddock, Moderately Eroded Setting Landform: Stream terraces Landform position (three-dimensional): Mountainbase, tread Down-slope shape: Linear Across-slope shape: Linear Parent material: Old alluvium Typical profile Ap - 0 to 11 inches: clay loam Bt - 11 to 57 inches: clay BC - 57 to 80 inches: loam Properties and qualities Slope: 2 to 15 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: Medium Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water storage in profile: High (about 9.0 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3e Hydrologic Soil Group: B Hydric soil rating: No Description of Urban Land Setting Parent material: Streets, parking lots, buildings, and other structures Custom Soil Resource Report 13 Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 8s Hydric soil rating: No Minor Components Udorthents Percent of map unit: 9 percent Landform: Stream terraces Landform position (three-dimensional): Mountainbase, tread Down-slope shape: Linear, convex Across-slope shape: Linear, convex Hydric soil rating: No Thurmont Percent of map unit: 4 percent Landform: Drainageways on stream terraces Landform position (three-dimensional): Mountainbase, base slope Down-slope shape: Concave, linear Across-slope shape: Linear Hydric soil rating: No Dillard, rarely flooded Percent of map unit: 3 percent Landform: Drainageways on stream terraces Landform position (three-dimensional): Mountainbase, base slope Down-slope shape: Concave, linear Across-slope shape: Linear Hydric soil rating: No Hemphill, undrained Percent of map unit: 2 percent Landform: Swales on stream terraces Landform position (three-dimensional): Mountainbase, base slope Down-slope shape: Concave, linear Across-slope shape: Concave, linear Hydric soil rating: Yes Reddies, occasionally flooded Percent of map unit: 2 percent Landform: Flood plains Landform position (three-dimensional): Mountainbase Down-slope shape: Linear Across-slope shape: Linear Hydric soil rating: No Custom Soil Resource Report 14 CrD—Cowee-Evard-Urban land complex, 15 to 30 percent slopes Map Unit Setting National map unit symbol: lc7t Elevation: 1,400 to 4,000 feet Mean annual precipitation: 40 to 80 inches Mean annual air temperature: 46 to 57 degrees F Frost-free period: 130 to 180 days Farmland classification: Not prime farmland Map Unit Composition Cowee and similar soils: 40 percent Evard and similar soils: 25 percent Urban land: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Cowee Setting Landform: Ridges, mountain slopes Landform position (two-dimensional): Summit, backslope Landform position (three-dimensional): Upper third of mountainflank, side slope Down-slope shape: Convex Across-slope shape: Linear Parent material: Residuum weathered from igneous and metamorphic rock Typical profile A - 0 to 10 inches: sandy loam Bt - 10 to 38 inches: clay loam Cr - 38 to 80 inches: weathered bedrock Properties and qualities Slope: 15 to 30 percent Depth to restrictive feature: 20 to 40 inches to paralithic bedrock Natural drainage class: Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Very low to high (0.00 to 1.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water storage in profile: Low (about 5.8 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4e Hydrologic Soil Group: C Hydric soil rating: No Custom Soil Resource Report 15 Description of Evard Setting Landform: Ridges, mountain slopes Landform position (two-dimensional): Summit, backslope Landform position (three-dimensional): Upper third of mountainflank, side slope Down-slope shape: Convex Across-slope shape: Linear Parent material: Residuum weathered from igneous and metamorphic rock Typical profile Ap - 0 to 5 inches: clay loam Bt - 5 to 29 inches: sandy clay loam BC - 29 to 37 inches: sandy loam C - 37 to 80 inches: sandy loam Properties and qualities Slope: 15 to 30 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water storage in profile: Moderate (about 8.3 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4e Hydrologic Soil Group: B Hydric soil rating: No Description of Urban Land Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 8 Hydric soil rating: No EvE—Evard-Cowee complex, 30 to 50 percent slopes Map Unit Setting National map unit symbol: 2vx26 Elevation: 1,680 to 4,880 feet Mean annual precipitation: 37 to 82 inches Mean annual air temperature: 46 to 57 degrees F Frost-free period: 140 to 203 days Custom Soil Resource Report 16 Farmland classification: Not prime farmland Map Unit Composition Evard and similar soils: 50 percent Cowee and similar soils: 26 percent Minor components: 24 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Evard Setting Landform: Ridges, mountain slopes Landform position (two-dimensional): Summit, backslope Landform position (three-dimensional): Mountaintop, mountainflank, crest, side slope Down-slope shape: Linear, convex Across-slope shape: Convex, linear Parent material: Residuum weathered from biotite gneiss and/or amphibolite that is affected by soil creep in the upper solum Typical profile A - 0 to 5 inches: gravelly loam Bt - 5 to 29 inches: sandy clay loam BC - 29 to 37 inches: sandy loam C - 37 to 80 inches: sandy loam Properties and qualities Slope: 30 to 50 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water storage in profile: Moderate (about 8.5 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 6e Hydrologic Soil Group: B Hydric soil rating: No Description of Cowee Setting Landform: Ridges, mountain slopes Landform position (two-dimensional): Summit, backslope Landform position (three-dimensional): Mountainflank, crest, side slope Down-slope shape: Convex Across-slope shape: Linear Parent material: Residuum weathered from biotite gneiss and/or amphibolite that is affected by soil creep in the upper solum Typical profile A - 0 to 5 inches: loam Custom Soil Resource Report 17 Bt - 5 to 27 inches: clay loam Cr - 27 to 80 inches: bedrock Properties and qualities Slope: 30 to 50 percent Depth to restrictive feature: 20 to 40 inches to paralithic bedrock Natural drainage class: Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Very low to high (0.00 to 1.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water storage in profile: Low (about 3.7 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 6s Hydrologic Soil Group: C Hydric soil rating: No Minor Components Edneyville, stony Percent of map unit: 10 percent Landform: Mountain slopes, ridges Landform position (two-dimensional): Backslope, summit Landform position (three-dimensional): Mountainflank, mountaintop, side slope, crest Down-slope shape: Convex, linear Across-slope shape: Convex Hydric soil rating: No Saunook, stony Percent of map unit: 6 percent Landform: Toes on drainageways Landform position (two-dimensional): Footslope Landform position (three-dimensional): Mountainbase, upper third of mountainflank, base slope, head slope Down-slope shape: Linear, concave Across-slope shape: Concave Hydric soil rating: No Trimont, stony Percent of map unit: 4 percent Landform: Mountain slopes, hillslopes Landform position (two-dimensional): Backslope Landform position (three-dimensional): Mountainflank, side slope, head slope Down-slope shape: Concave, linear Across-slope shape: Linear Hydric soil rating: No Chestnut, stony Percent of map unit: 4 percent Landform: Ridges, mountain slopes Landform position (two-dimensional): Summit, backslope Custom Soil Resource Report 18 Landform position (three-dimensional): Mountaintop, mountainflank, crest, side slope Down-slope shape: Linear, convex Across-slope shape: Convex Hydric soil rating: No Custom Soil Resource Report 19 References American Association of State Highway and Transportation Officials (AASHTO). 2004. Standard specifications for transportation materials and methods of sampling and testing. 24th edition. American Society for Testing and Materials (ASTM). 2005. Standard classification of soils for engineering purposes. ASTM Standard D2487-00. Cowardin, L.M., V. Carter, F.C. Golet, and E.T. LaRoe. 1979. Classification of wetlands and deep-water habitats of the United States. U.S. Fish and Wildlife Service FWS/OBS-79/31. Federal Register. July 13, 1994. Changes in hydric soils of the United States. Federal Register. September 18, 2002. Hydric soils of the United States. Hurt, G.W., and L.M. Vasilas, editors. Version 6.0, 2006. Field indicators of hydric soils in the United States. National Research Council. 1995. Wetlands: Characteristics and boundaries. Soil Survey Division Staff. 1993. Soil survey manual. Soil Conservation Service. U.S. Department of Agriculture Handbook 18. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/national/soils/?cid=nrcs142p2_054262 Soil Survey Staff. 1999. Soil taxonomy: A basic system of soil classification for making and interpreting soil surveys. 2nd edition. Natural Resources Conservation Service, U.S. Department of Agriculture Handbook 436. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053577 Soil Survey Staff. 2010. Keys to soil taxonomy. 11th edition. U.S. Department of Agriculture, Natural Resources Conservation Service. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053580 Tiner, R.W., Jr. 1985. Wetlands of Delaware. U.S. Fish and Wildlife Service and Delaware Department of Natural Resources and Environmental Control, Wetlands Section. United States Army Corps of Engineers, Environmental Laboratory. 1987. Corps of Engineers wetlands delineation manual. Waterways Experiment Station Technical Report Y-87-1. United States Department of Agriculture, Natural Resources Conservation Service. National forestry manual. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/ home/?cid=nrcs142p2_053374 United States Department of Agriculture, Natural Resources Conservation Service. National range and pasture handbook. http://www.nrcs.usda.gov/wps/portal/nrcs/ detail/national/landuse/rangepasture/?cid=stelprdb1043084 20 United States Department of Agriculture, Natural Resources Conservation Service. National soil survey handbook, title 430-VI. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/soils/scientists/?cid=nrcs142p2_054242 United States Department of Agriculture, Natural Resources Conservation Service. 2006. Land resource regions and major land resource areas of the United States, the Caribbean, and the Pacific Basin. U.S. Department of Agriculture Handbook 296. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/? cid=nrcs142p2_053624 United States Department of Agriculture, Soil Conservation Service. 1961. Land capability classification. U.S. Department of Agriculture Handbook 210. http:// www.nrcs.usda.gov/Internet/FSE_DOCUMENTS/nrcs142p2_052290.pdf Custom Soil Resource Report 21 11LEINC. BUNNELL-LAMMONS ENGINEERING, INC. GEOTEMOCM, ENVIRONMENTAL ANO CONSTRUCTION MATF RIALS CONSULTANTS May 4, 2018 Mr. Patrick Bradshaw, P.E. Civil Design Concepts, P.A. 168 Patton Avenue Asheville, North Carolina 28801 Subject: GEOTECHNICAL EXPLORATION REPORT Proposed Central Drive Parking Area / Option C Western Carolina University Cullowhee, North Carolina BLE Project No. J18-12232-01 Dear Mr. Bradshaw: Bunnell-Lammons Engineering, Inc. (BLE) is pleased to present this report of subsurface investigation for the subject project. Our services were provided in general accordance with our Proposal P18-1061 dated December 1, 2017. The purpose of this exploration was to develop information about the site and subsurface conditions that could be used to facilitate the design of the project. Project information was obtained from conversations with Mr. Patrick Bradshaw, P.E. with Civil Design Concepts along with a Concept Site Plan (option C) dated January 2018 developed by Civil Design Concepts. Additional project information was obtained from a site visit by Mr. Sam Interlicchia of BLE and a review of publicly available current and historical aerial photography. PROJECT INFORMATION Western Carolina University is currently planning the construction of a new parking facility west of Central Drive and south Merlite Court on the Western Carolina University Campus. The new parking lot layout is approximately 15,980 square feet in size and will provide 441 parking spaces. Two entrance and exit drives are proposed to be located on the eastern portion of the parking lot connecting to Central Drive. The conceptual site plan indicates that cuts up to 25 feet and fills up to 30 feet may be required to establish proposed site grades. Construction of two site retaining walls is also proposed. The type of retaining wall construction is not known yet; however, we understand that Wall A is proposed to be located on the south side of the proposed parking area and is anticipated to have a maximum height of approximate 18 feet. The second wall, (Wall B) is proposed to be located on the north side of the parking area and is anticipated to have a maximum height of 10 feet. The project will also include the relocation of approximately 900 linear feet of sanitary sewer and the piping of approximately 440 linear feet of an un -named creek running through the site. The pipe will be installed from the south end of the site beneath the fill and parking area and will terminate roughly 100 feet from Merlite Court. The creek will be routed through a 60 -inch diameter concrete pipe. 130 OVAL ROAD, SUITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828) 277-0110 L E nic. Geotechnical Exploration Report May 4, 2018 Proposed Central Drive Parking Area /Option C BLE Project No. J18-12232-01 Field Exploration The exploration consisted of performing a total of eight soil test borings to depths ranging from 10 feet to 35 feet below existing grade along with five test pit excavations to depths of ranging from 6 feet to 10 feet below existing grade. The approximate boring and test pit locations are shown on the Boring and Test Pit Location Plan, Figure 1. The soil test borings were performed using a truck -mounted drill rig using hollow -stem augers. Soil samples were obtained in accordance with ASTM D 1586 by driving a 1-3/8 inch I.D. split -spoon sampler with a 140 -pound safety hammer. The test pits were excavated by a rubber tire back -hoe. In each of the test pits, dynamic cone penetrometer (DCP) testing was performed to quantify the consistency of the soils. The testing was only performed in the upper four feet of the test pit due to the size and depth of the excavation. The locations for the borings and test pits were established in the field by our Mr. Sam Interlicchia by referencing the provided drawing and using existing site features such as existing sewer manholes and roadways as reference points. The ground surface elevations at the boring locations were interpolated from the elevations contours shown on the provided drawing. As such, the boring and test pit locations and elevations referenced in this report and shown on the figures and field records should be considered approximate. The Soil Test Boring logs and Test Pit Records and a description of our field procedures are attached to this report. Site and Subsurface Conditions Area Geoloo The project site is located in the Blue Ridge Physiographic Province. The bedrock in this region is a complex crystalline formation that has been faulted and contorted by past tectonic movements. The rock has weathered to residual soils which form the mantle for the hillsides and hilltops. The typical residual soil profile in areas not disturbed by erosion or human activities consists of clayey soils near the surface where weathering is more advanced, underlain by sandy silts and silty sands. The boundary between soil and rock is not sharply defined, and there often is a transitional zone, termed "partially weathered rock," overlying the parent bedrock. Partially weathered rock is defined, for engineering purposes, as residual material with standard penetration resistances in excess of 100 blows per foot (bpf). Weathering is facilitated by fractures, joints, and the presence of less resistant rock types. Consequently, the profile of the partially weathered rock and hard rock is quite irregular and erratic, even over short horizontal distances. Also, it is not unusual to find lenses and boulders of hard rock and/or zones of partially weathered rock within the soil mantle, well above the general bedrock level. The upper soils along drainage features and in flood plain areas are typically water -deposited (alluvial) materials that have been eroded and washed down from adjacent higher ground. These alluvial soils are usually soft and compressible, having never been consolidated by pressures in excess of their present overburden. RLISwc. Geotechnical Exploration Report May 4, 2018 Proposed Central Drive Parking Area /Option C BLE Project No. J18-12232-01 Site Conditions Site conditions were observed by Mr. Sam C. Interlicchia during our site reconnaissance. The subject site is located to the west of Central Drive and to the south of Merlite Court. Generally speaking, the western portion of the site slopes down from the west toward an un -named creek that bisects the site. The ground cover consists of scattered mature trees and thick underbrush on the western most portion of the site and a grassy area between Ed Norton Road and the creek. Ed Norton Road is a gravel and soil single lane roadway that traverses generally in a north to south direction along the west edge of the site. The eastern portion of the site has been previously graded; (Figure 3); however, based on our previous experience on the campus and a review of publicly available aerial photography, the eastern portion of the site originally sloped down to the west towards the creek. We understand that the eastern portion of the site was raised by approximately 18 to 24 feet of fill soils brought to the site during various other campus projects. No information regarding the past grading work has been provided to BLE at the time this report was prepared. However, based on our correspondence with Western Carolina. University personnel, we understand the soil fill was generally compacted in lifts as the soil fill was brought to the site. Due to the thick underbrush along the creek banks, a majority of the creek was not observed; however, where observed the creek appeared to be approximately 16 to 24 inches in width and incised approximately 2 to 3 feet below the adjacent ground surface. Based on our site observations and review of historical aerial photographs, it appears that there may have been several structures located on the subject site, which have since been razed (Figure 2). Some remnants (i.e. masonry block) were observed along the east side of Ed Norton Road. There were no visible rock outcroppings or groundwater springs observed during our site visit with the exception of the unnamed creek. We note that this is a large site and we did not observe all surface conditions. Conditions differing from the above-described are plausible. Subsurface Conditions The descriptions below provide a general summary of the subsurface conditions encountered. The Boring Logs and Test Pit Records included in the appendix contain detailed information recorded at each test location. The Boring Logs and Test Pit Records represent our interpretation of the field logs based on engineering examination of the field samples. The lines designating the interfaces between various strata represent approximate boundaries and the transition between strata may be gradual. It should be noted that the soil conditions will vary between test locations. Soil Test Borings Beneath a soil surface at soil test borings B-1 through B-7 and an approximate 2 -inch thick layer of organic -laden topsoil at soil test boring B-8, fill soils comprised of damp very loose and firm silty sand, was encountered to depths of between 8%i and 23%z feet below the existing ground surface. No information regarding the past grading work has been provided to BLE at the time of reporting. However, as previously mentioned, we understand that the eastern portion of the site was raised to its current grade by fill soil brought to the property during another campus project. No compaction test data or field records of fill placement were available for our review at the time this report was prepared. IRLEW. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Based on the standard penetration resistance (blow counts, N values) that ranged from 4 to 16 blows per foot, the existing fill generally appears to have received some compactive effort during original placement. Most of the fill was generally free of organic$ and deleterious materials; however, the fill soil in soil test boring B-4 was noted to have organic matter and roots in the soil matrix at a depth of 3 %z to 6 feet below the existing grade. Asphalt fragments were also encountered in the soil matrix at a depth of 12%i to 15 feet below the existing grade. It should be noted that the content and quality of man-made fills can vary significantly. Residual soil typical of the Blue Ridge Physiographic Province were encountered below the previously described fill soils at all eight soil test borings. The residual soils predominantly consisted of very loose to firm damp to wet silty sands. Standard penetration resistance (blow counts, N values) ranged from 3 to 17 blows per foot, typically becoming firmer with depth. Partially weathered rock (residual material that is transitional between soil and rock with standard penetration resistance of 100 blows per foot or more) was encountered underlying the residual soil in soil test boring B-1 at a depth of 29 feet below the existing ground surface. The PWR sampled as silty fine to medium sand. All eight soil test borings were terminated in residual soil or partially weathered rock. Groundwater was encountered in soil test borings B-5 and B-6 at depths of 5 feet and 11 feet, respectfully below the existing ground surface approximately 24 hours after being drilled. Borings B-1, B-2, B-3, B-4, B-7 and B-8 caved at depths varying from 9 feet to 23 feet below the existing ground surface approximately 24 hours after being drilled. Borehole cave-in depth can be an indication that groundwater is in the vicinity. On completion of checking for the presence of water the bore holes a hole plug was inserted and the bore hole backfilled with auger cuttings. Groundwater levels may fluctuate several feet with seasonal and rainfall variations and with changes in the water level in adjacent un -named creek. Normally, the highest ground -water levels occur in late winter and spring and the lowest levels occur in late summer and fall. Ground water levels may also fluctuate due to construction activity. Test Pit Excavations Five shallow test pit excavations were excavated on the western portion of the site. The excavation was performed by a rubber -tired back hoe. The test pits were excavated to depths of between 6 and 10 feet below the existing ground surface. Dynamic cone penetrometer (DCP) testing was performed in the test pit excavations to quantify the consistency of the soils. The testing was only performed in the upper four feet of the test pit, due to the size and depth of the excavation. The locations were generally selected based on accessibility, but were spaced out across the subject areas with the intent of exploring a representative range of subgrade conditions. In the areas explored by test pits, the surface composition typically consists of weeds and/or grass underlain by approximately 3 to 5 inch thick topsoil/root layer. Beneath a grass/soil surface, fill soil consisting of loose and firm silty sand was encountered in all five test pit excavation locations to depths of between 1 and 8 feet below the existing grade. Beneath the existing fill soils, residual soils were encountered. The residual soils typically consisted loose to firm silty sand. The subgrade soils were also noted to be damp at the time the fieldwork was performed. Upon completion of the testing, the excavations were backfilled with the soil spoils. 2 ,RLIBINC. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Ground water was not encountered during or at completion of the test pit operations. Groundwater levels may fluctuate several feet with seasonal and rainfall variations and with changes in the water level in adjacent un -named creek. Normally, the highest ground -water levels occur in late winter and spring and the lowest levels occur in late summer and fall. Ground water levels may also fluctuate due to construction activity. Laboratory Test Results Soil samples processed for laboratory testing were obtained from test pit excavations TP -1 and TP -2. Samples were collected from soil spoils brought to the surface by the back -hoe bucket. The laboratory testing performed on the selected soil samples is described below, the results of which are summarized in Table 1 below. • Natural moisture content: The moisture content of the soil is the ratio, expressed as a percentage, of the weight of water in a given mass of soil to the weight of the soil particles and was determined in accordance with ASTM D 2216. • A moisture -density relationship test (standard Proctor) was performed on bulk samples from test pit excavations TP -1 and TP -2 to determine compaction characteristics, including the maximum dry density and optimum moisture content. The results are presented on the attached Moisture Density Relationship Test report in the Appendix. The soil samples collected were generally classified as silty sands with low plasticity (SM), and were found to have natural moisture contents above the laboratory determined optimum moisture content (see Table 1 below). It should be noted that moisture contents on a large grading project will be dictated to some degree by the prevailing weather at the time of construction. Tahle 1 - Lnhoratory Test Recultc General Assessment The Central Drive parking lot site has had significant development occur over the years. There are several generations of fill that have been placed on the subject site; the east side of the site has had significantly thick fill placed over it. Generally speaking, these fill soils appear to have had some compactive effort applied during grading; however, the upper several feet of fill soil have been exposed to the elements and have softened. We anticipate that in prevailing warm dry weather this softer soil could be improved by scarifying, drying and reworking the soil. In contrast, Boring B4 indicates the extreme north end of the fill did not receive the same level of compaction and contains organics and asphalt fragments. As such, we recommend that test pit excavations be considered to further evaluate the encountered condition. The test pit excavations could be performed prior to site grading or in conjunction with site grading operations. 5 Optimum Sample Test Pit Sample Natural Maximum Dry Moisture ID. No. Depth (feet) Moisture (%) Density (pcf) Content (%) 105.7 18.8 101.1 21.8 S-1 TP -1 4 to 6 24.3 S-2 TP -2 6 to 8 30.2 General Assessment The Central Drive parking lot site has had significant development occur over the years. There are several generations of fill that have been placed on the subject site; the east side of the site has had significantly thick fill placed over it. Generally speaking, these fill soils appear to have had some compactive effort applied during grading; however, the upper several feet of fill soil have been exposed to the elements and have softened. We anticipate that in prevailing warm dry weather this softer soil could be improved by scarifying, drying and reworking the soil. In contrast, Boring B4 indicates the extreme north end of the fill did not receive the same level of compaction and contains organics and asphalt fragments. As such, we recommend that test pit excavations be considered to further evaluate the encountered condition. The test pit excavations could be performed prior to site grading or in conjunction with site grading operations. 5 EL IENC. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 The soils at the toe of the existing fill slope are marginal and may require some subgrade stabilization before commencing of any overlying fill. We also anticipate that poor to marginal soil conditions when developing the bedding for the concrete pipe, as well as the wet areas adjacent to the creek. Subgrade stabilization will be required, particularly in areas beneath the retaining walls, and can generally be achieved by undercutting portions of the unsuitable soils (the depth of undercutting should be determined in the field by BLE at the time of construction) and backfilled with crushed stone (i.e. #57 stone). A heavy woven geotextile or biaxial geogrid may also be required. As previously mentioned, groundwater was encountered about 5 to 11 feet below the existing ground surface. Based on our review of the provide drawing, the current groundwater elevation is not within the expected construction depths. However, excavation for deeper utilities may extend below the encountered groundwater level. The test pit excavations located on the proposed borrow area were extended to a depth of 8 feet with little excavation difficulty. Based on these test pits, this material should be excavatable using conventional earthmoving equipment. Based on the test pit data, the borrow soil is suitable for use as structural fill material; however, the laboratory data indicates that the soils are wet of their optimum moisture and will require drying prior to be used. Based upon our review of the provided drawing, several site retaining walls, and fill embankments are planned for the project. Site retaining walls should be designed by a /North Carolina registered professional engineer, and should include an evaluation of global stability, as this will control grid lengths for the wall. It is possible that the borings and test pit excavations may not fully represent the conditions across the entire site. Since the site was previously developed, unexpected conditions, such as buried debris, loose/soft fill soils and/or abandoned utilities can be present between the field test locations and as such, some selective undercutting may be required at some locations. Additional soil test borings, test pit exploration, laboratory testing and analysis maybe needed as the project advances. Assuming subsurface conditions encountered at the boring locations are representative of subsurface conditions elsewhere on the site the following preliminary conclusions and recommendations should generally be applicable for this site. Concrete Pipe Based on our review of the provided drawing, we understand that site grading will include the piping of approximately 440 linear feet of the un -named creek. We anticipate that soils in the creek bed and around the creek banks will be soft/loose and will not be suitable for direct support of the proposed culvert and overlying fill soil. As such, we recommend that an allowance be budgeted to undercut some of the existing soils. It is recommended that at least 12 inches of #57 stone be placed beneath the pipe for bedding, and that the stone be brought up to the springline of the pipe. A heavy woven geotextile or biaxial geogrid may also be required along with the use of crushed rock to provide a suitable subgrade. We recommend that the undercutting and installation/construction of the culvert be monitored by BLE full time. Ground water control is anticipated to be required during excavation and construction of the culvert. This control can be accomplished by means of diversion berms and pumping from gravel lined, cased sumps or well points located outside of the excavation. A cutoff drain may also be required to control lateral seepage into the excavation. 6 13E INC. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Lateral Earth Pressure Retaining walls must be capable of resisting the lateral earth pressures that will be imposed on them. Based on previously developed correlations for similar soils, the following soil properties and earth pressures coefficients provided in Table 2 are recommended for use. Table 2 Recommended Soil Properties and Earth Pressure Coefficients Effective Stress Properties Earth Pressure Coefficients Material Total Unit Cohesion Angle of Internal Description Weight (psf) Friction (degrees) fro K,) Kp* compacted fill 120 0 30 0.50 0.33 3.0 silty sand+ clean washed 100 0 40 0.36 0.22 --- stone 957) Note: Ko = At -Rest earth pressure coefficient Ka = Active earth pressure coefficient Kp = Passive earth pressure coefficient IL * We recommend a factor of safety of 2 be used with the passive earth pressure coefficients. + Subject to revision pending identitication of till source used for backfill * We recommend a factor of safety of 2 be used with the passive earth pressure coefficients. Walls which will be prevented from rotating such as below grade walls braced against the upper floor level should be designed to resist the "at -rest" lateral earth pressure. Walls such as exterior retaining walls which are permitted to rotate at the top may be designed to resist "active" lateral earth pressure. Typically, a top rotation of about 1 inch per 10 feet height of wall is sufficient to develop active pressure conditions in soils similar to those encountered at the site. Less deflection would be required to develop active conditions if crushed stone is used as backfill. The total unit weight of the backfill soil should be used with the above earth pressure coefficients to calculate lateral earth pressures. Lateral pressure arising from surcharge loading, earthquake loading, and ground water, should be added to the above soil earth pressures to determine the total lateral pressures which the walls must resist. A positive drainage system should be incorporated behind below grade walls. The drainage system should have sufficient capacity to prevent the buildup of excess hydrostatic head behind the wall. The drainage system should incorporate appropriately graded sand and aggregate material or geotextile fabric to prevent the loss of fines which could be transported into the drainage system. Drain cleanouts should be provided. In addition, transient loads imposed on the walls by construction equipment during backfilling should be taken into consideration during design and construction. Excessively heavy grading equipment (that could impose temporary excessive pressures or long-term excessive residual pressures against the constructed walls) should not be allowed within about 5 feet (horizontally) of the walls. A coefficient of 0.35 could be reasonably assumed for evaluating ultimate frictional resistance to sliding at the soil to foundation contact. We recommend the passive earth pressure be divided by a safety factor of at least 2 to limit the amount of lateral deformation required to mobilize the passive resistance. 7 E E .C. Geotechnical Exploration Report May 4, 2018 Proposed Central Drive Parking Area 10ptlon C BLE Project No. J18-12232-01 GENERAL GRADING RECOMMENDATIONS Site Preparation Site preparation should include the removal of all unsuitable surface materials (asphalt, concrete, surface debris, surface vegetation, topsoil, and root systems) and disposed of offsite. Topsoil and organic soils may be stockpiled for later use in areas to be landscaped. Site preparation should also include the removal of all existing grade slabs and shallow foundations (if present) from the previously razed structures. All existing abandoned utilities should be removed and replaced with engineered fill or plugged prior to construction. If pipes are not removed or plugged, they may serve as conduits for subsurface erosion resulting in settlements or sinkholes. The surface should be kept smooth and sloped to provide positive drainage and surface water runoff should be routed to ditches adjacent to the work area. ProofrollinL- After the removal of all unsuitable surface materials and before any grading commences, we recommend that areas to provide support for the pavement area be carefully inspected for soft surficial soils and proofrolled with a 20 to 25 -ton, four -wheeled, rubber -tired roller or similar approved equipment. The proofroller should make at least four passes over each location, with the last two passes perpendicular to the first two. Any areas which wave, rut, or deflect excessively and continue to do so after several passes of the proofroller should be excavated to firmer soils. The excavated areas should be backfilled in thin lifts with engineered fill as recommended in this report. Proofrolling and excavating operations should be monitored by an experienced engineering technician working under the direction of the BLE geotechnical engineer. Proofrolling should not be performed during or immediately after periods of precipitation or when the ground is frozen. In areas where the subgrade is found to be unstable under the proofroll, remedial activities may be necessary. Such remedial activities may include partial undercutting and replacement, or stabilization with geo-synthetics and crushed stone, or a combination of these methods. Appropriate recommendations may be provided at the time of construction by BLE, if unsatisfactory proofrolling conditions are encountered. Stabilization measures will vary with location, and will also be dependent on the weather conditions during construction. Engineered Fill All fill used for raising site grade or for replacement of material that is undercut should be uniformly compacted in thin lifts to at least 95 percent of the standard Proctor maximum dry density (ASTM D 698). Beneath parking areas and roadways, the compaction requirement should be raised to 98 percent in the upper 12 inches. The soils to be used in the engineered fill should contain no more than 3 percent organic matter by weight and should be free of roots, limbs, other deleterious material and rocks larger than 6 -inches in diameter. In addition, the moisture content of the compacted soil fill should be maintained within plus or minus 3 percent of the optimum moisture content as determined from the standard proctor compaction test during placement and compaction. This provision may require the contractor to dry soils during periods of wet weather or to wet soils during dry periods. The fill soils should have a Plasticity Index (PI) of less than 30, and a maximum dry density of no less than 90 pounds per cubic foot (pco. Q 1«IGINC. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Fill material should be constructed in horizontal stages starting at the base of the existing slopes. Prior to each stage of fill placement, the sloped area should be benched into the existing soils with a level pad. The level pad will allow for better compaction of the fill materials. The resulting series of level benches will also serve to break the potential slip plane between the compacted fill layers. All fill placed in embankments should be compacted to a similar requirement as discussed above. Because it is difficult to compact soil at the face of embankments, it may be necessary to construct the slopes outside their design limits, and then cut them back, leaving the exposed face well -compacted. The soils at this site will vary from slightly too highly erodible from rainwater runoff. We recommend that the face of slopes and embankments be protected by establishing vegetation as soon as practical after grading. Suitability of On -Site Borrow Based on our limited examination of the soils from the borings, the soil samples collected were generally classified as silty sands with low plasticity (SM) and were found to be damp to wet at the time of our exploration. The laboratory data indicates that the soils will require drying prior to be used. However, it should be noted that moisture contents on a large grading project will be dictated to some degree by the prevailing weather at the time of construction. Evaluation of Off -Site Borrow If off-site borrow is proposed for use, representative samples of each proposed fill material should be collected and evaluated against the above-described criteria prior to the beginning of placement. In -Place Field Density Testing Once compaction begins, a sufficient number of density tests should be performed by an experienced engineering technician working under the direction of the geotechnical engineer to measure the degree of compaction being obtained. Settlement Monitoring Portions of the site will be raised by as much as about 25 to 30 feet with new fill. The mass weight of this fill will cause the underlying soils to undergo consolidation settlement. We expect that most all of the settlement will take place during grading operations. However, good design and construction practice requires that this settlement be monitored and verified prior to construction. To achieve this, we suggest that a number of settlement monitors be established after the placement of fill and their movement monitored by precise surveying techniques. Measurements should be made about every 5 days. This information should be furnished to the BLE Geotechnical Engineer for review. We suggest that a minimum 3 to 4 week delay period be programmed into the construction schedule between the time grading is complete and the time the pavement is paved. Excavation and Groundwater Control Excavation may extend below the encountered groundwater level for deep utilities. Excavations could also encounter perched groundwater within the existing soils above the general ground water level. Contractors will need to be prepared to control groundwater during construction by underdrains and pumping from filtered sumps. ,RL INC. Geotechnical Exploration Report Proposed Central Drive Parlang Area /Option C May 4, 2018 BLE Project No. J18-12232-01 If perched or high ground water levels are encountered, installation of french drains may help lower the ground water within the site and capture perched water that may be above the general groundwater level. A french drain can be constructed by e?ccavating a trench, lining the trench with filter fabric (Mirafi 140N or equal), backfilling the trench with about 6 inches of washed, crushed No. 57 stone, placing a perforated pipe in the stone, filling over top of the pipe with an additional 12 inches of stone, wrapping the fabric over the top of the crushed stone, and then covering the drain with properly compacted soil fill. The drains should be sloped toward an outlet on the low side of the site or tie into the storm drain system, if approved by the civil engineer. BLE should be consulted, if higher than anticipated groundwater levels are encountered. Grading on the western portion of the site will require excavation of predominantly moderate consistency residual soils. Based on the field testing and our experience, this material should be excavatable using conventional earthmoving equipment. Although we do not expect there will be extensive excavation difficulty, dense residual soil and/or zones of partially weathered rock may exist between the field test locations within the soil mantle. It should be noted these materials can vary erratically across the site in regard to depth, consistency and bedding All excavations should be sloped or shored in accordance with local, state, and federal regulations, including OSHA (29 CFR Part 1926) excavation trench safety standards. The contractor is solely responsible for site safety. Cut and Fill SloRes Fill slopes should initially be constructed beyond the design slope edge due to the difficulty of compacting the edge of slopes. The fill could then be cut back leaving the exposed face well compacted. Fill slopes should be adequately compacted in accordance with the recommendations of this report. Fill embankment slopes have been designed to have an inclination of 2H:1 V (horizontal to vertical). Typically, we suggest that fill slopes be constructed at 2.5:1, (horizontal to vertical) or flatter. As such, these steeper slopes will be more susceptible to erosion and shallow sloughing than those built at a flatter inclination. Cut and fill slope surfaces should be protected from erosion by grassing or other means. Any disturbed soils located on the existing slope faces should be removed. Once removed and prior to fill placement, the exposed subgrade should be inspected for soft soils. Fill material should be constructed in horizontal stages starting at the base of the existing slope. Prior to each stage of fill placement, the sloped area should be benched into the existing soils with a level pad. The level pad will allow for better compaction of the fill materials. The resulting series of level benches will also serve to break the potential slip plane between the compacted fill layers. All fill placed in embankments should be compacted to a similar requirement as discussed above. Because it is difficult to compact soil at the face of embankments, it may be necessary to construct the slopes outside their design limits, and then cut them back, leaving the exposed face well - compacted. The soils at this site will vary from slightly too highly erodible from rainwater runoff. We recommend that the face of slopes and embankments be protected by establishing vegetation as soon as practical after grading. 10 BLEW. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Pavement Subgrades We have not been provided with specific traffic loading and frequency information for a formal pavement design and have not performed laboratory or field CBR tests. However, a pavement section consisting of 2 inches of asphalt underlain by 8 -inches of aggregate base course is typical for areas subject to only automobile traffic loads. In driveways and areas that will be traversed by the Catamount on -campus transportation system, or other similar type of vehicles, we suggest an increased pavement section of 3 -inches of asphalt to prolong pavement life. These pavement sections have demonstrated acceptable performance with subsurface conditions similar to this site. The asphalt surface course should conform to the North Carolina Department of Transportation (NCDOT) Standard Specification, Section 610, for Type S-9.513 Superpave mixture. The base course material should be Aggregate Base Course conforming to NCDOT Standard Specification, Section 520, for Type B aggregate. The base course should be compacted to 100 percent of the modified Proctor (ASTM D-1.557) maximum dry density. The pavement subgrades should be prepared as recommended in this report. If the subgrades proofroll successfully, then the suggested pavement sections can be placed. In areas where the subgrade is found to be unstable under the proofroll, remedial activities may be necessary. Such remedial activities may include partial undercutting and replacement, or stabilization with geosynthetics and crushed stone, or a combination of these. Appropriate recommendations may be provided at the time of construction by BLE, if unsatisfactory proofrolling conditions are encountered. Basis of Recommendations Our evaluation has been based on our understanding of the project information and data obtained in our exploration as well as our experience on similar projects. The general subsurface conditions utilized in our evaluation have been based on interpolation of the subsurface data between the borings. Subsurface conditions between the borings may differ. If the project information is incorrect or the structure location (horizontal or vertical) and/or dimensions are changed, please contact us so that our recommendations can be reviewed. The discovery of any site or subsurface conditions during construction which deviate from the data obtained in this exploration should be reported to us for our evaluation. The assessment of site environmental conditions for presence of pollutants in the soil, rock and groundwater of the site was beyond the scope of this exploration. It is recommended that Bunnell-Lammons Engineering be provided the opportunity to make a general review of the earthwork plans and specifications prepared from the recommendations presented in this report. We would then suggest any modifications so that our recommendations are properly interpreted and implemented. I I,A IEINC.. Geotechnical Exploration Report Proposed Central Drive Parking Area /Option C May 4, 2018 BLE Project No. J18-12232-01 Closing We appreciate the opportunity to provide our professional- geotechnical services on this project. If you have any questions regarding this report please to not hesitate to call us. We also offer construction materials and technician field testing services. We hope that you will give BLE consideration to provide testing services as this project enters the construction phase. Sincerely, BUNNELL-LANIMONS ENGINEERING, INC. \`\`\\\ C II///,// / 111/// /F \��o�� �._,� y9 Sam C. Int ischia SWilileezBr , '.E. 0309 t8 Project Manager Manager Registered, North Carolinaiv� SNE . •� \�� 1J A'r_ �\ 12 Attachments: Boring Location Plan (Figure 1) Aerial Photographs (Figure 2 & 3) Soil Test Boring Records Test Pit Excavation Records Key to Soil Symbols and Classifications Laboratory Soil Data Field Exploration Procedures -.-�. �. � rte'.• !EZ7 �.�. Li:�-,r 7C t, T •x + 4 f y}¢ f erw a�w.ru. _ 5 r L 5 ® Approximate Soil Test Boring Location Approximate Test Pit Excavation Location nat aua t Soil Test Boring & Test Pit Location Plan Date: 11 L 16 Proposed Central Drive Parking Area / Option C May 2018 Western Carolina University Figure No. BUNNELL-LAMMONS ENGINEERING BLE Project No. J18-12232-01 BUNNELL-LAMMONS ENGINEERING Google Earth Pro Aerial Photograph Dated March 2013 Western Carolina University BLE Project No. J18-12232-01 N Date: May 2018 Figure No. 2 N MO C. BUN NELL4.A)RA10110 ENGNEERNG, Will Qn=cww-ALAwENvvwmwm%%L COMWLTAM" ELEVATIOW DEPTH (FT) BORING NO. B-1 PROJECT: WCU Central Drive Parking Lot CLIENT: Civil Design Concepts LOCATION: Cullowhee, NC DRILLER: Jordan Environmental, LLC, Adam Hart DRILLING METHOD: D-50, 21/4" Hollow Stem Auger DEPTH TO - WATER> INITIAL: �z AFTER 24 HOURS: 1 SOIL DESCRIPTION SOIL TYPE Very loose and firm, damp, red brown, clayey, silty fine to medium SAND (SM) - (fill) 2 1 2220 t t 0 .., ,.: .. 4 3 4 2215t15 r ' T KpFirm, damp, dark red, slightly micaceous, silty fine to medium SAND (SM)- T,,-. -'N 9 5 - (residuum) 2210 20 2205125 I 40 Partially Weathered Rock which sampled as dark brown, micaceous, silty W62200 30 fine to medium sand Boring terminated at 30 feet. No groundwater encountered at time of boring. Boring caved at 18.5 feet at time of drilling. 0 3 2195-35 L 7 V PROJECT NO.: J18-12232-01 START: 03/05/18 END: 03/15/18 ELEVATION: 2230 LOGGED BY: S. Intedicchla CAVING>= 18.5 STANDARD PENETRATION RESULTS BLOWS/FOOT 2 5 10 20 30 40 50 TO 90 ............_................................ ......................... ' cors BORING NO. B•1 Sheet 1 of 1 9 2 2225--5 4 4 4 r 2220 t t 0 .., ,.: .. 4 3 4 2215t15 r ' T KpFirm, damp, dark red, slightly micaceous, silty fine to medium SAND (SM)- T,,-. -'N 9 5 - (residuum) 2210 20 2205125 I 40 Partially Weathered Rock which sampled as dark brown, micaceous, silty W62200 30 fine to medium sand Boring terminated at 30 feet. No groundwater encountered at time of boring. Boring caved at 18.5 feet at time of drilling. 0 3 2195-35 L 7 V PROJECT NO.: J18-12232-01 START: 03/05/18 END: 03/15/18 ELEVATION: 2230 LOGGED BY: S. Intedicchla CAVING>= 18.5 STANDARD PENETRATION RESULTS BLOWS/FOOT 2 5 10 20 30 40 50 TO 90 ............_................................ ......................... ' cors BORING NO. B•1 Sheet 1 of 1 111 A MING. BORING NO. B-2 PROJECT: WCU Central Drive Parking Lot BUNNELL-LAMMONS CLIENT: Civil Design Concept ENGINEEMG, ING LOCATION: Cullowhee, NC OEOTEcwcALANDENVRONMENTAL DRILLER: Jordan Environmental, LLC, Adam Hart CONSULTAMTS DRILLING METHOD: D-50, 2114" Hollow Stem Auger DEPTH TO - WATER> INITIAL: �z AFTER 24 HOURS: 1 ELEVATION/ DEPTH (FT) 2225 2220 f 10 2215+15 2210 -1- 20 2205 + 25 2200-30 2195 135 SOIL DESCRIPTION Very loose and firm, damp, red brown, clayey, silty fine to medium (SM) with scattered rock fragments - (fill) Loose, damp, dark red, slightly micaceous, silty fine to medium SAND (SM) - (resdiuum) Firm, damp, pale red, micaceous, slimy fine to medium SAND (SM} Boring terminated at 30 feet. No groundwater encountered at time of boring. Boring caved at 20.5 feet at time of drilling. PROJECT NO.: J18-12232-01 START: 03/05118 END: 03/15118 ELEVATION: 2230 LOGGED BY: S. Interlicchia CAVING>3W 20.5 SOIL STANDARD PENETRATION RESULTS TYPE BLOWS/FOOT 2 5 10 20 30 40 50 TO 90 1 BORING NO. B-2 Sheet 1 of 1 d . ,y 4 . • 4 +t -: s BORING NO. B-2 Sheet 1 of 1 BORING NO. B-3 PROJECT: WCU Central Drive Parking Lot BUNNELL-LAMMONS CLIENT: Civil Design Concepts ENGINEERNG, INC. LOCATION: Cullowhee, NC GE0TECHNcALAmEw4vmmENmkL DRILLER: Jordan Environmental, LLC, Adam Hart CONSULTANTS DRILLING METHOD: D -W, 21/4" Hollow Stem Auer_ DEPTH TO - WATER> INITIAL: AFTER 24 HOURS: 1 PROJECT NO.: J18-12232-01 START: 03/05/18 END: 03/15/18 ELEVATION: 2225 LOGGED BY: S. Interlicchia CAVING>M7 23 ELEVATION/ SOIL DESCRIPTION SOIL STANDARD PENETRATION RESULTS DEPTH (FT) TYPE BLOWS/FOOT 2 5 10 20 30 40 50 70 90 Very loose and firm, red brown, clayey, silty fine to medium SAND (SM) with scattered rock fragments -(fill)=- - 2 .............•..•..•••..• •••. + . 3 2220 5 :Y # :;. " 4 2215 10 .`; 5 2210 115 10 :...:....:..� 5 " B 2205-20 Firm, damp, pale red, micaceous, silty fine to medium SAND (SM) - (residuum) ; ->' :...:.......:..:....:... 2200 25 $ .. 2195-30 $ e 21K--35 - Boring terminated at 35 feet. ..... :...:....:................ ........ :..:..: No groundwater encountered at time of boring. iBoring caved at 23 feet at time of boring. BORING NO. B-3 Sheet 1 of 1 11LENC BORING NO. B-4 PROJECT: WCU Central Drive Parking Lot PROJECT NO.: J18-12232-01 BUNNELUAMMONS CLIENT: Civil Design Concepts START: 03/05118 END: 03/15118 EI IMEEROIS, INC. LOCATION: Cullowhee, NC._ ELEVATION: 2220 GEoTECHmcALAwENVRo1a1Bm DRILLER: Jordan Environmental, LLC, Adam Hart LOGGED BY: S. Interlicchia CONsuLTAM M DRILLING METHOD: D-50, 21/4" Hollow Stem Auger DEPTH TO - WATER> INITIAL. S-Z. AFTER 24 HOURS:1 CAVING>3M 21 ELEVATION/ SOIL DESCRIPTION SOIL STANDARD PENETRATION RESULTS DEPTH (FT) TYPE 2 BLOWSMOOT 2 5 10 20 30 40 50 70 90 Loose and firm, damp, dark red to brown, slightly clayey, silty fine to medium SAND (SM) with asphalt pieces from 12.5' to 15' and organic 3 matter and roots from 3.5'- 6'. - (fill) 4 s • 3 13 4 • 2215 5 6 6 • 5 4 2210-10 10 7 6 • 2205-15 i 3 3 3 • 2200-20 Very loose to firm, damp, pale red, micaceous, silty fine to medium 2 SAND (SM) - (residuum) • 2195-25 3 5 a • 2190 30 Boring terminated at 30 feet. No groundwater encountered at time of boring. Boring caved at 21 feet at time of boring. 2185-35 a c? 0 N N N J J W 3 0 BORING NO. B-4 Uj Sheet 1 of 1 ELEw. I BORING NO. B-5 PROJECT: WCU Central Drive Parking Lot PROJECT NO.: J18-12232-01 BIINELL-CANNONS CLIENT: Civil Design Concepts START: 03/05/18 END: 03/15/18 EMNEERNG, M. LOCATION: Cullowhee, NC ELEVATION: 2205 GEoTEcmcnLAwENvwo L DRILLER: Jordan Environmental, LLC, Adam Hart LOGGED BY: S. Interlicchia CONSULTANTS DRILLING METHOD: D,50,2 1/4" Hollow Stem A_ uger DEPTH TO - WATER> INITIAL: 11 AFTER 24 HOURS: 1 5 CAVING>M ELEVATIOW DEPTH (FT) SOIL DESCRIPTION Very loose, wet, dark brown to tan, very silty fine to (fill) 2200--$ Firm, wet, pale brown, very 2195 10 2190 15 21"T 185 20 2180 25 i 2175 30 2170-35 to medium Loose, damp, dark brown, slightly micaceous, silty fine to medium SAND (SM) Boring terminated at 15 feet. Groundwater encountered at 11 feet at time of drilling. Groundwater measured at 5 feet 24 hours after drilling. SOIL 11 STANDARD PENETRATION RESULTS TYPE BLOWS/FOOT 2 2 �. 2 1 3 14 y; 3 BORING NO. B-5 Sheet 1 of 1 I LENC, BORING NO. B-6 PROJECT: WCU Central Drive Parking Lot PROJECT NO.: J18-12232-01 BUNNELL-LAMMONS CLIENT: Civil Design Concepts START: 03/05118 END: 03/15/18 ENGNEERN% INC. LOCATION: Cullowhee, NC ELEVATION: 2205. GEoTECHWcALALwEwxwm IBnxL DRILLER: Jordan Environmental, LLC, Adam Hart LOGGED BY: - S. Interlicchia CONSIXTAIM DRILLING METHOD: D-50,2 114" Hollow Stem Auger DEPTH TO - WATER> INITIAL: Q 15 AFTER 24 HOURS: t 11 CAVING>= ELEVATION/ SOIL DESCRIPTION SOIL STANDARD PENETRATION RESULTS DEPTH (FT) TYPE BLOWS/FOOT 2 5 10 20 30 40 50 70 90 Very loose and firm, damp, dark brown, silty fine to medium SAND (SM) with scattered gravel and asphalt pieces - (fill) 2 • 5 2 2 • 2200-5 4 4 7 • Loose, wet, yellowish tan, very silty, fine to medium SAND (SM) - (residuum) 5 � 2195-10 Very loose to loose, damp, dark brownish red, micaceous, silty fine to t medium SAND (SM) :: • 2190 15 2 z • 2185-20 4 Boring terminated at 20 feet. Groundwater encountered at 15 feet at time of drilling. Groundwater measured at 11 feet 24 hours after drilling. 12180+25 1 2175+30 I 2170+ 35 i tl BORING NO. B-6 Sheet 1 of 1 J LMINc BORING NO. B-7 PROJECT: WCU Central Drive Parking Lot PROJECT NO.: J18-1.2232-01 BIIINELL-LAMMONS CLIENT: Civil Design Concepts START: 03/05/18 END: 03/15/18 ENGINEERNG, INC. LOCATION: Cullowhee, NC ELEVATION: 2208 (kvmc Hw.ALAwDENvRowwwmL DRILLER: Jordan Environmental, LLC, Adam Hart LOGGED BY: S. Interlicchla CONWLTAKM DRILLING METHOD: D5_0, 21/4" Hollow Stem Aupor DEPTH TO - WATER> INITIAL: �_z AFTER 24 HOURS: 1 CAVING>77 10.5 ELEVATION/ DEPTH (FT) 2205 6 2200 —10 2195 I X15 SOIL DESCRIPTION loose and firm, damp, grayish brown, silty fine to medium with scattered rock fragments - (fill) )ose to loose, dar (SM) - (residuum) Boring terminated at 15 feet. No groundwater encountered at time of boring. T Boring caved at 10.5 feet at time of drilling. 2190-- 20 1 2185-- 2180-- 2175- -35 18521802175-35 L _ 7 n 2170 — SOIL TYPE 5I STANDARD PEONETRATION RESULTS 2 5 10 20 30 40 50 70 90 1 �..............:. 7 i :...:....:..:..:....:...:................:.. 2 3 �. 2 ........... 2 9 BORING NO. B-7 Sheet 1 of 1 13LENC. BUNNELL-LAMMONS ENGINEERNG, INC. OEoTEcHMcALAw ENvM0M ENTAL CONSULTANTS ELEVATION] DEPTH (FT) 2195--15 2190 f 20 ;1155-1-25 2180-1-30 0 2175 35 L V 3emI1«>;Lem PROJECT: WCU Central Drive Parking Lot PROJECT NO.: J18-12232-01 CLIENT: Civil Design. Concepts START: 03/05/18 END: 03/15/18 LOCATION: Cullowhee, NC ELEVATION: 2210 DRILLER: Jordan Environmental, LLC, Adam Hart LOGGED BY: S. Interlicchia DRILLING METHOD: D.50, 21/4" Hollow Stem Auger DEPTH TO - WATER> INITIAL: Q AFTER 24 HOURS: 1 CAVING>= 10 SOIL DESCRIPTION Very loose, wet, tan brown, very silty fine to medium SAND (SM) - (MI) Firm and loose, wet, dark brown and black, very medium SAND (SM) - (residuum) SOIL TYPE gI STANDARD PENETRATION RESULTSBLOWSI 2 5 10 20 30 40 50 70 90 2 2 t 4 :...:....:..................:.. .:..:..:..:.. T: 3 BORING NO. B-8 Sheet 1 of 1 L EINC. BUNNELL-LAMMONS ENGINEERING, INC. GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS TEST PIT LOG Job Name: WCU / Central Drive Parking Test Pit Number: TP -1 Job Number: J18-12232-01 Date Logged: March 5, 2018 Approximate Surface Elevation: Logged By: Sam Interlicchia Depth Dynamic Cone Stratum Description Penetrometer From To blows/increment st - 2nd - 3rd 0 6" leaf litter/topsoil/roots --- 4-4-5 6" 81 Fill - Reddish brown moist 5-6-5 slightly clayey silty sand 5-5-6 6-6-7 Residual — Light red, 81 10, damp, micaceous silty fine - medium Sand Test Pit terminated @ 10 feet Remarks and Notes: Groundwater not observed at time of excavation. Bulk sample obtained between 4 and 6 feet Test Pit backfilled with excavated soil. 130 OVAL ROAD, SUITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828) 277-0110 NLMINC. BUNNELL-LAMMONS ENGINEERING, INC. GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS TEST PIT LOG Job Name: WCU / Central Drive Parking Job Number: J18-12232-01 Approximate Surface Elevation: 2248± Depth From To Test Pit Number: TP -2 Date Logged: March 5, 2018 Logged By: Sam Interlicchia Dynamic Cone Stratum Description Penetrometer blows/increment f 1 st _ 2nd - 3rd � 0 6' leaf litter/topsoil/roots --- 3-4-4 6" 4, Fill - Reddish brown moist 6-6-5 slightly clayey silty sand 5-5-5 6-8-8 Residual — Purplish red, i 4' 10' damp, micaceous silty fine- medium Sand Test Pit terminated @ 10 feet Remarks and Notes: Groundwater not observed at time of excavation. Bulk sample obtained between 6 and 8 feet Test Pit backfilled with excavated soil. 130 OvAL ROAD, SUITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828) 277-0110 1 ,A INC BUNNELL-LAMMONS ENGINEERING, INC. GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS TEST PIT LOG Job Name: WCU / Central Drive Parking Job Number: J18-12232-01 Approximate Surface Elevation: 2192± Depth From CI 4" 12" 11. L7. Test Pit Number: TP -3 Date Logged: March 5, 2018 Logged By: Sam Interlicchia Dynamic Cone Stratum Description Penetrometer blows/increment 1st - 2nd - 3rd 4" grass/topsoil/roots 12" Fill — Light red moist slightly clayey silty sand Residual — Tannish yellow, 6' damp, micaceous silty fine - medium Sand Test Pit terminated @ 6 feet Remarks and Notes: Groundwater not observed at time of excavation. Test Pit backfilled with excavated soil. 3-4-4 4-5-5 5-5-6 6-7-7 130 OVAL ROAD, SITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828) 277-0110 1 L E INC. BUNNELL-LAMMONS ENGINEERING, INC. GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS TEST PIT LOG Job Name: WCU / Central Drive Parking Job Number: J18-12232-01 Approximate Surface Elevation: 2200± Depth From 0 3" 12" ' To Test Pit Number: TP -4 Date Logged: March 5, 2018 Logged By: Sam Interlicchia Dynamic Cone Stratum Description Penetrometer blows/increment st - 2nd -3 rd T. grass/topsoil/roots --� 12" Fill — Light red moist slightly clayey silty sand Residual — Tannish yellow, 6' damp, micaceous silty fine - medium Sand Residual — Light tan, 8' damp, micaceous silty fine - medium Sand Test Pit terminated @ 8 feet Remarks and Notes: Groundwater not observed at time of excavation. Test Pit backfilled with excavated soil. 3-3-5 4-5-5 5-5-7 5-7-7 130 OVAL ROAD, SUITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828)277-0110 1EINC. BUNNELL-LAMMONS ENGINEERING, INC. GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS TEST PIT LOG Job Name: WCU / Central Drive Parking Job Number: J18-12232-01 Approximate Surface Elevation: 2200± Depth From 6" 8' To 1.1 3 Test Pit Number: TP -5 Date Logged: March 5, 2018 Logged By: Sam Interlicchia Dynamic Cone Stratum Description Penetrometer blows/increment Ils" _ 2nd - 3rd leaf litter/Topsoil/roots Fill - Reddish brown moist slightly clayey silty sand Residual — Light red, 10' damp, micaceous silty fine -medium Sand Test Pit terminated @ 10 feet Remarks and Notes: Groundwater not observed at time of excavation. Test Pit backfilled with excavated soil. 4-4-5 5-6-5 5-5-6 6-6-7 130 OVAL ROAD, SUITE 200 PHONE (828) 277-0100 ARDEN, NORTH CAROLINA 28704 FAX (828) 277-0110 KEY TO SOIL CLASSIFICATIONS AND CONSISTENCY DESCRIPTIONS BUNNELL-LAMMONS ENGINEERING, INC. ASHEVILLE, NORTH CAROLINA Penetration Resistance* Relative Sandy Silt Blows per Foot Density Particle Size Identification SANDS BEDROCK Boulder: Greater than 300 mm Cobble: 75 to 300 mm 0 to 4 Very Loose Gravel: 5 to 10 Loose Coarse - 19 to 75 mm 11 to 20 Firm Fine - 4.75 to 19 mm 21 to 30 Very Firm Sand: 31 to 50 Dense Coarse - 2 to 4.75 mm over 50 Very Dense Medium - 0.425 to 2 mm Fine - 0.075 to 0.425 mm Silt &Clay: Less than 0.075 mm Penetration Resistance* Consistency Blows per Foot SIL IS and CLAYS 0 to 2 3to4 5to8 9 to 15 16 to 30 31 to 50 over 50 'ASTM D 1586 ® Grab Sample ® Split Spoon Sample Undistrurbed Sample Well -graded Gravel GW a o cCT p �Q Poorly -graded Gravel o GP Very Soft Soft Firm Stiff Very Stiff Hard Very Hard KEY TO DRILLING SYMBOLS 12 Number of blows in first 6 -inches 15 Number of blows in second 6 -inches 16 Number of blows in third 6 -inches Groundwater Table at Time of Drilling Groundwater Table 24 Hours after Completion of Drilling KEY TO SOIL CLASSIFICATIONS Low Plasticity Clay CIL ////////// Partially Weathered Rock Silty Clay BLDRCBBL CHh Plasticity Clay Silt ML amClayey SiltSilty Sand MH SM L-rr Clayey Sand Concrete SC A5 . r- Sandy Silt "f 4'+• "-- Topsoil MLS L -11-1—r _ TOPSOIL L-rr Clayey Sand Concrete SC A5 . Sand El Bedrock SW BEDROCK L-rr Clayey Sand Concrete SC A5 . MOISTURE DENSITY RELATIONSHIP TEST REPORT 120 115 I -• 110 -. -4 ---1-4-- U Q I w ' i ---�--- I � 105- I 4 ; 100 ._ .._;. ZAV for Sp.G. _ 2.70 95 10 15 20 25 30 35 40 Water content, % Test specification: ASTM D 698-00a Method A Standard Elev/ Classification Nat. Sp.G. LL RI % > % < Depth USCS AASHTO Moist. #4 No.200 4-o SM 24.3 TEST RESULTS MATERIAL DESCRIPTION Nlaximtnn dry density = 105.7 pef Red brown, slightly clayey, silty fine to medium SAND (SM) Optimum moisture = 18.8 % Project No. J18-12232- Client: Civil Design Concepts Remarks: Project: WCU Central Avenue Parking Source of Sample: 'fest Pit #1 Sample Number: S-1 BUNNELL-LAMMONS ENGINEERING, INC. Asheville, North Carolina Plate Tested By: BKJ _,__ _ __ Checked By: SCI 110 105 100 U a MOISTURE DENSITY RELATIONSHIP TEST REPORT .9 ZAV for Sp.G. _ 85 2.70 10 15 20 25 30 35 40 Water content, % Test specification: ASTM D 698-00a Method A Standard Elev/ Classification Nat. LL PI % > % < Depth USCS AASHTO Moist. Sp.G. #4 No.200 6-8 SM 302 TEST RESULTS MATERIAL DESCRIPTION Purplish red, very silty fine to medium Maximum dry density = I Ol .l pcf SAND (SM) Optimum moisture = 21.8 % Project No. J 18-12232- Client: Civil Design Concepts Remarks: Project: WCU Central Avenue Parking :> Source of Sample: Test Pit . 2 Sample Number: S-2 BUNNELL-LAMMONS ENGINEERING, INC. Asheville, North Carolina Plate Tested By: BKJ Checked By: SCI Field Exploration Procedures SOIL TEST BORINGS The borings were made by mechanically twisting a continuous flight steel auger into the soil. Soil sampling and penetration testing were performed in accordance with ASTM D- 1586. At assigned intervals, soil samples were obtained with a standard 1.4 -inch I.D., 2 -inch O.D., split -tube sampler. The sampler was first seated 6 inches to penetrate any loose cuttings, and then driven an additional 12 inches with blows of a 140 -pound hammer falling 30 inches. The number of hammer blows required to drive the sampler the final 12 inches was recorded and is designated the "standard penetration resistance." The penetration resistance, once properly evaluated, is an index to the strength of the soil and foundation supporting capability. Representative portions of the soil samples, thus obtained, were placed in glass jars and transported to the laboratory. In the laboratory, the samples were examined by a geotechnical engineer to verify the field classifications made by the driller. Soil Test Boring Records are attached showing the soil descriptions and penetration resistances. TEST PITS The test pits were excavated by a rubber -tired trackhoe operated by others. The trackhoe had a maximum reach of about 10 feet. The soils encountered were identified in the field from spoils brought to the surface by the backhoe bucket. Soil descriptions are tabulated on the attached Test Pit Logs. Imagery................................................NAIP, January 2010Roads..............................................©2006-2010 Tele AtlasNames...............................................................GNIS, 2010Hydrography.................National Hydrography Dataset, 2010Contours............................National Elevation Dataset, 2010 ―│―│―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│―│―│―│ ―│ ―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│―│―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│―│ ―│―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│ ―│ ―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│―│ ―│ ―│ ―│―│ ―│―│ ―│―│ ―│ ―│ ―│ ▄▄OP ▄▄OP #!" #!" #!" ▄▄OP #!" #!" #!" ▄▄OP #!" #!" ¥^ █n █n █n █n █n F F F 36002000 240 02000 2400340024 0 0 2600 3000 28002800 2200 24 0 0 2400 2 2 0 0 2200260026002 6 0 0 2200 2800 2600 22003200 2400240024003200340026003600360 0 24002200240030002400 2200300044 0 0 2600 40002400200026004200 280022002600 360020003200 320026002400 300034 0 0 320 0 2800 24 0 0 36002600 34003200240026002400 22 0 0 320028003000 22 0 0 260030003 6 0 03200 360032003200 340022 0 0 22002800 2200 340034002400 2400220034002400 34 0 0 2400 34002200 2400220034002200 320032003000 300022002200 3800300 02200 24002200 280022 0 0 30 0 0 2600 2200220 0260030002600 2400 3000 240 0 2200 36002400 40003000380028002600 3400 28003200 26003400 3400220032002 4 0 03000 220 032003400 2200 36002 2 0 0 42003200 2 0 0 0 36 0 0 20003000 2800 30002400280 0 22 0 0 320026003000 2800 30002 2 0 0 240 0 32002200280022002200 24002200280024 0 0 2600300034002400 3000 3600 3 2 0 0 28003400 2400 3200 26003000 2200 3000 340022002600 4000300034002600 3800 40003600220022002 4 0 0 240030002 2 0 0 2200 380022002200 3400 3000 22002600 22002600 260026002400 260030002200 2800 24002 8 0 0 2200 3000 360032 0 0 2600 3000 34 0 0 28003400 320030 0 0 3600340036 0 0 2600300038002600 3400 340024002200340038 0 0 2600 2400 22002200 2200 400038002 6 0 0 40003600320 0 3 6 0 0 3000320038003400280026 0 0 2600280022002 4 0 0 2800 28 0 0 2200 2400 240 0 22002400 2800220034003 4 0 0 2 2 0 0 32004000 3400 36003 0 0 0 380026 0 0 32003200 260036002400340 0 2200 240042 0 0 3 6 0 0 44002800 260030003 2 0 0 3600 3000 280026003600 2200 2200220 0 2400 2200240024003800 220 0 320030003000 2800340 0 3600 3600240040003800 260046002400 2800 2800 38002200 4000280022002400 38002200240030 0 0 240026002200240 0 220 0 2600300032002800 26003 0 0 0 2 6 0 0 2400 340028 0 03600 220 0 280024002800 3400 3800 4000 340036 0 0 JacksonCountyAirport 7202 7202 7202B 7202B 7202A 7202 4650A 4650 £¤Bus23 £¤2374 £¤Bus23 £¤2374 ¬«107 ¬«107 ¬«107 ¬«107 ¬«107 ¬«116 ¬«107 ¬«116 ¬«107 P U M P K I N T O W N PUMPKINTOW N WAYEHUTTASHEEP KNOBL A N D S GAP SHEEP KNOBTATHAM CREEKFLAT BRANCH MILL ST W MAIN ST NANTAHALA NATIONAL FOREST HodgeLake FradyCoveLake B l a k e Br Parker Br Bryson Br Cane CrWayehutta CrL ittle S a v a n n a h C r Bumgarner BrCullowhee CrLocust CrCaney ForkWayehutta CrE Fork S a v a n n a h C r Cope Cr Webster CrYellow Bird Br Mill CrCullowhee CrCox BrL o n g B r M in e B r Moses CrDeets CrSavanna h CrE Fork Savannah Cr Savannah Cr Tilley CrCope C r Wayehutta CrRocky Fac e B r M ill CrA s h B r P r e s s l e y C r Cope CrCherry G ap B rC u l l owhee CrTuckasegee RiverTuckasege e R i v e rTuckasegee RiverT u c k a s egee RiverTuckasegee River McGuireLake SouthwesternCommunityColl WesternCarolinaUniv LoveChapelCem ParrisCem Ash Cem Wyke Cem StillwellCem Cox Cem RogersCem CULLOWHEE Sylva Sylva Webster Tuckasegee RubyCity LoveField ForestHills Fallcliff Speedwell EastLaport Ba r t C o v e Monteith Cove C o x C o v e WolfKnob ParkerKnob SheepKnob JennyKnob PineyKnob WebsterKnob BuckKnob HooperKnob Ebb Knob BeckKnob RobertsonMtn CherryKnob BlackMtn AlumKnob BuckKnob PantherKnob RockyFace KingsMtn LittlePanther Knob BerryMtn SheltonMtn SavannahRidge HensonRidge SugarloafRidge MilksickRidge SugarloafRidge CarverRidge RockyFaceRidge MidRidge CullowheeMtn GreatBalsamMountains GribbleGap DicksGap Flat Gap ChestnutGap SoapstoneGap CherryGap CedarCliffs Dicks GapBridge 16 580 30" 39 000 39 N 2 2 2 12' 3 35° 06 17' 39 13 15' 30"22' 20' 39 10 12 13 000m 97 30" 3 LV 3 3 3 3 05 3 3 E 30" 09 39 000m 15' 39 0639 39 96 KV 01 3 10' 3 000 FEET 08 35° 000m 39 15' 2 KV 00 01 3 83°07' 39 39 39 10 39 39 16 30" 22' N 35° 35° FEET 17' 08 09 39 39 96 12'30"3 10' 03 05 06 39 14 FEET 07 39 E 2 FEET 299 04 3 83° 04 39 04 05 30" 39 14 39 97 000 LV 02 04 06 000m 07' 05 11 1539 30" 000 83° 83° 11 39 15 15' 98 740 00 02 770 03 0739 39 39 20' 610 NORTHCAROLINA QUADRANGLE LOCATION SYLVA SOUTH QUADRANGLENORTH CAROLINA-JACKSON CO.7.5-MINUTE SERIES SYLVA SOUTH, NC 2016 Expressway Local Connector ROAD CLASSIFICATION Ramp 4WD Secondary Hwy Local Road Interstate Route State RouteUS RouteWX./H SYLVA SOUTH, NC 2016 ROAD CLASSIFICATION Check with local Forest Service unitfor current travel conditions and restrictions. FS Primary Route FS High Clearance RouteFS PassengerRouteª«­▬Interstate Route State RouteUS RouteWX./H Expressway Local Connector Ramp 4WD Secondary Hwy Local Road U.S. DEPARTMENT OF THE INTERIOR U.S. GEOLOGICAL SURVEY 1 Whittier 8 Big Ridge 2 Sylva North3 Hazelwood4 Greens Creek5 Tuckasegee6 Corbin Knob7 Glenville ADJOINING QUADRANGLES 1 2 3 4 5 6 7 8 This map was produced to conform with the National Geospatial Program US Topo Product Standard, 2011.A metadata file associated with this product is draft version 0.6.19 CONTOUR INTERVAL 40 FEETNORTH AMERICAN VERTICAL DATUM OF 1988 SCALE 1:24 000 1000 500 0 METERS 1000 2000 21KILOMETERS00.51 1 0.5 0 MILES 1 1000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 FEET Imagery<IMG_LEADER><IMG_CITATION>Roads<TRANS_LEADER> U.S. Census Bureau, 2015 - 2016Names<GNIS_LEADER>GNIS, 2016Hydrography<HYDRO_LEADER>National Hydrography Dataset, <HYDRO_DATE>Contours<HYPSO_LEADER><HYPSO_CITATION>Boundaries............Multiple sources; see metadata file 1972 - 2016<OPTIONAL_CITATIONS>Wetlands.........FWS National Wetlands Inventory 1977 - 2014 North American Datum of 1983 (NAD83)World Geodetic System of 1984 (WGS84). Projection and1 000-meter grid: Universal Transverse Mercator, Zone 17S Produced by the United States Geological Survey 10 000-foot ticks: North Carolina Coordinate System of 1983 This map is not a legal document. Boundaries may begeneralized for this map scale. Private lands within governmentreservations may not be shown. Obtain permission beforeentering private lands. North American Datum of 1983 (NAD83)World Geodetic System of 1984 (WGS84). Projection and1 000-meter grid: Universal Transverse Mercator, Zone 17S Produced by the United States Geological Survey 10 000-foot ticks: North Carolina Coordinate System of 1983 This map is not a legal document. Boundaries may begeneralized for this map scale. Private lands within governmentreservations may not be shown. Obtain permission beforeentering private lands. Imagery.............................................NAIP, October 2014Roads................................ U.S. Census Bureau, 2015 - 2016Roads within US Forest Service Lands.............FSTopo Data with limited Forest Service updates, 2012 - 2016Names...............................................................GNIS, 2016Hydrography....................National Hydrography Dataset, 2014Contours............................National Elevation Dataset, 2008Boundaries............Multiple sources; see metadata file 1972 - 2016 Wetlands.........FWS National Wetlands Inventory 1977 - 2014 U.S. National Grid 100,000-m Square ID Grid Zone Designation KV LV 3 00 17S ^ ØMN GN UTM GRID AND 2016 MAGNETIC NORTHDECLINATION AT CENTER OF SHEET 1° 16´22 MILS 6° 3´108 MILS *7643016379276*NSN.7643016379276NGA REF NO.USGSX24K71777 Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/AirbusDS, U SDA, USGS, AeroGRID, IGN, and the GIS User Community National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250Feet Ü83°10'54.28"W 35°18'42.29"N 83°10'16.82"W 35°18'12.93"N SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOODHAZARD AR EAS Without Base Flood Elevation (BFE)Zone A, V, A99With BFE or Depth Zone AE, AO, AH, VE, ARRegulatory Floodway 0.2% Annual Chance Flood Hazard, Areasof 1% annual chance flood with averagedepth less than one foot or with drainageareas of less than one square mile Zone X Future Conditions 1% AnnualChance Flood Hazard Zone XArea with Reduced Flood Risk due toLevee. See Notes.Zone X Area with Flood Risk due to Levee Zone D NO SCREE N Area of Minimal Flood Hazard Zone X Area of Undetermined Flood Hazard Zone D Channel, Culver t, or Storm SewerLevee, Dike, or Floodwall Cross Sections with 1% Annual Chance17.5 Water Surface ElevationCoastal Transect Coastal Transect BaselineProfile BaselineHydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of StudyJurisdiction Boundar y Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The base map shown complies with FEMA's base map accuracy standards The flood hazard information is derived directly from theauthoritative NFHL web services provided by FEMA. This mapwas exported on 6/19/2018 at 2:49:22 PM and does notreflect changes or amendments subsequent to this date andtime. The NFHL and effective information may change orbecome superseded by new data over time. This map image is void if the one or more of the following mapelements do not appear: base map imagery, flood zone labels,legend, scale bar, map creation date, community identifiers,FIRM panel number, and FIRM effective date. Map images forunmapped and unmodernized areas cannot be used forregulatory purposes. Legend OTHER AREAS OFFLOOD HAZARD OTHER AREAS GENERALSTRUCTURES OTHERFEATURES MAP PANELS 8 1:6,000 B 20.2 NOAA Atlas 14, Volume 2, Version 3 Location name: Sylva, North Carolina, USA* Latitude: 35.3256°, Longitude: -83.1911° Elevation: 2045.5 ft** * source: ESRI Maps ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF_tabular | PF_graphical | Maps_&_aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches/hour)1 Duration Average recurrence interval (years) 1 2 5 10 25 50 100 200 500 1000 5-min 4.22 (3.80‑4.69) 4.92 (4.44‑5.46) 5.78 (5.21‑6.42) 6.65 (5.98‑7.38) 7.62 (6.80‑8.45) 8.45 (7.50‑9.37) 9.24 (8.15‑10.3) 10.0 (8.75‑11.2) 11.0 (9.48‑12.4) 11.9 (10.1‑13.5) 10-min 3.37 (3.04‑3.74) 3.94 (3.55‑4.37) 4.63 (4.17‑5.15) 5.32 (4.78‑5.90) 6.07 (5.42‑6.73) 6.73 (5.97‑7.46) 7.34 (6.47‑8.17) 7.94 (6.94‑8.88) 8.68 (7.49‑9.78) 9.34 (7.96‑10.6) 15-min 2.81 (2.53‑3.12) 3.30 (2.97‑3.66) 3.91 (3.52‑4.34) 4.48 (4.03‑4.98) 5.13 (4.58‑5.68) 5.68 (5.04‑6.30) 6.18 (5.45‑6.88) 6.68 (5.84‑7.47) 7.29 (6.29‑8.21) 7.82 (6.66‑8.88) 30-min 1.92 (1.74‑2.14) 2.28 (2.05‑2.53) 2.78 (2.50‑3.08) 3.25 (2.92‑3.60) 3.80 (3.39‑4.21) 4.27 (3.79‑4.74) 4.73 (4.17‑5.27) 5.20 (4.54‑5.81) 5.80 (5.00‑6.53) 6.33 (5.39‑7.19) 60-min 1.20 (1.08‑1.33) 1.43 (1.29‑1.59) 1.78 (1.60‑1.98) 2.12 (1.90‑2.35) 2.53 (2.26‑2.80) 2.90 (2.57‑3.21) 3.26 (2.88‑3.63) 3.65 (3.19‑4.08) 4.16 (3.59‑4.68) 4.62 (3.94‑5.25) 2-hr 0.708 (0.642‑0.786) 0.842 (0.762‑0.934) 1.04 (0.942‑1.15) 1.24 (1.11‑1.37) 1.48 (1.33‑1.64) 1.70 (1.51‑1.88) 1.92 (1.69‑2.13) 2.15 (1.87‑2.39) 2.45 (2.11‑2.76) 2.73 (2.31‑3.10) 3-hr 0.509 (0.464‑0.564) 0.601 (0.546‑0.665) 0.738 (0.671‑0.817) 0.875 (0.793‑0.965) 1.05 (0.947‑1.16) 1.22 (1.08‑1.34) 1.38 (1.22‑1.53) 1.56 (1.36‑1.73) 1.80 (1.55‑2.02) 2.02 (1.71‑2.29) 6-hr 0.322 (0.295‑0.355) 0.376 (0.345‑0.414) 0.453 (0.415‑0.499) 0.534 (0.487‑0.586) 0.640 (0.580‑0.702) 0.737 (0.662‑0.808) 0.838 (0.744‑0.921) 0.946 (0.830‑1.05) 1.10 (0.945‑1.22) 1.23 (1.04‑1.39) 12-hr 0.205 (0.189‑0.224) 0.240 (0.221‑0.262) 0.287 (0.264‑0.313) 0.334 (0.307‑0.364) 0.394 (0.360‑0.428) 0.446 (0.405‑0.485) 0.497 (0.448‑0.542) 0.550 (0.492‑0.601) 0.618 (0.547‑0.681) 0.676 (0.592‑0.752) 24-hr 0.116 (0.110‑0.123) 0.139 (0.131‑0.148) 0.170 (0.160‑0.181) 0.195 (0.184‑0.207) 0.230 (0.216‑0.244) 0.258 (0.241‑0.273) 0.286 (0.266‑0.304) 0.315 (0.292‑0.335) 0.355 (0.325‑0.377) 0.385 (0.351‑0.410) 2-day 0.070 (0.065‑0.074) 0.083 (0.078‑0.088) 0.101 (0.095‑0.107) 0.115 (0.108‑0.122) 0.134 (0.126‑0.143) 0.150 (0.140‑0.159) 0.165 (0.154‑0.176) 0.182 (0.168‑0.194) 0.203 (0.187‑0.217) 0.220 (0.201‑0.235) 3-day 0.050 (0.047‑0.053) 0.059 (0.056‑0.063) 0.072 (0.068‑0.076) 0.081 (0.077‑0.086) 0.094 (0.089‑0.100) 0.105 (0.098‑0.111) 0.115 (0.108‑0.122) 0.126 (0.117‑0.134) 0.139 (0.129‑0.148) 0.150 (0.138‑0.160) 4-day 0.040 (0.038‑0.043) 0.048 (0.045‑0.051) 0.057 (0.054‑0.061) 0.065 (0.061‑0.069) 0.074 (0.070‑0.079) 0.082 (0.078‑0.087) 0.090 (0.084‑0.095) 0.098 (0.091‑0.104) 0.107 (0.100‑0.114) 0.115 (0.106‑0.122) 7-day 0.028 (0.026‑0.030) 0.033 (0.031‑0.035) 0.039 (0.037‑0.042) 0.044 (0.042‑0.047) 0.051 (0.048‑0.055) 0.057 (0.053‑0.060) 0.062 (0.058‑0.066) 0.068 (0.063‑0.072) 0.075 (0.070‑0.080) 0.081 (0.075‑0.087) 10-day 0.022 (0.021‑0.024) 0.026 (0.025‑0.028) 0.031 (0.030‑0.033) 0.035 (0.033‑0.037) 0.040 (0.038‑0.043) 0.045 (0.042‑0.047) 0.049 (0.046‑0.052) 0.053 (0.049‑0.056) 0.058 (0.054‑0.062) 0.062 (0.058‑0.067) 20-day 0.015 (0.015‑0.016) 0.018 (0.017‑0.019) 0.021 (0.020‑0.022) 0.023 (0.022‑0.024) 0.026 (0.025‑0.028) 0.028 (0.027‑0.030) 0.031 (0.029‑0.032) 0.033 (0.031‑0.034) 0.035 (0.033‑0.037) 0.037 (0.035‑0.039) 30-day 0.013 (0.012‑0.013) 0.015 (0.014‑0.015) 0.017 (0.016‑0.018) 0.018 (0.018‑0.019) 0.020 (0.020‑0.021) 0.022 (0.021‑0.023) 0.023 (0.022‑0.024) 0.025 (0.023‑0.026) 0.026 (0.025‑0.028) 0.027 (0.026‑0.029) 45-day 0.011 (0.010‑0.011) 0.013 (0.012‑0.013) 0.014 (0.014‑0.015) 0.015 (0.015‑0.016) 0.017 (0.016‑0.017) 0.018 (0.017‑0.018) 0.018 (0.018‑0.019) 0.019 (0.018‑0.020) 0.020 (0.019‑0.021) 0.021 (0.020‑0.022) 60-day 0.010 (0.009‑0.010) 0.011 (0.011‑0.012) 0.013 (0.012‑0.013) 0.014 (0.013‑0.014) 0.015 (0.014‑0.015) 0.016 (0.015‑0.016) 0.016 (0.016‑0.017) 0.017 (0.016‑0.018) 0.017 (0.017‑0.018) 0.018 (0.017‑0.019) 1 Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. Back to Top PF graphical Precipitation Frequency Data Server https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.3256&... 1 of 4 5/30/2018, 11:52 AM NOAA Atlas 14, Volume 2, Version 3 CULLOWHEE Station ID: 31-2200 Location name: Sylva, North Carolina, USA* Latitude: 35.3256°, Longitude: -83.1911° Elevation: Elevation (station metadata): 2192 ft** * source: ESRI Maps ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF_tabular | PF_graphical | Maps_&_aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Duration Average recurrence interval (years) 1 2 5 10 25 50 100 200 500 1000 5-min 0.352 (0.317‑0.391) 0.410 (0.370‑0.455) 0.482 (0.434‑0.535) 0.554 (0.498‑0.615) 0.635 (0.567‑0.704) 0.704 (0.625‑0.781) 0.770 (0.679‑0.857) 0.835 (0.729‑0.934) 0.915 (0.790‑1.03) 0.989 (0.842‑1.12) 10-min 0.562 (0.506‑0.624) 0.656 (0.591‑0.728) 0.772 (0.695‑0.858) 0.886 (0.796‑0.983) 1.01 (0.903‑1.12) 1.12 (0.995‑1.24) 1.22 (1.08‑1.36) 1.32 (1.16‑1.48) 1.45 (1.25‑1.63) 1.56 (1.33‑1.77) 15-min 0.702 (0.633‑0.780) 0.825 (0.743‑0.916) 0.977 (0.879‑1.09) 1.12 (1.01‑1.24) 1.28 (1.14‑1.42) 1.42 (1.26‑1.58) 1.55 (1.36‑1.72) 1.67 (1.46‑1.87) 1.82 (1.57‑2.05) 1.96 (1.67‑2.22) 30-min 0.962 (0.868‑1.07) 1.14 (1.03‑1.26) 1.39 (1.25‑1.54) 1.62 (1.46‑1.80) 1.90 (1.70‑2.11) 2.14 (1.90‑2.37) 2.37 (2.09‑2.64) 2.60 (2.27‑2.91) 2.90 (2.50‑3.27) 3.17 (2.70‑3.60) 60-min 1.20 (1.08‑1.33) 1.43 (1.29‑1.59) 1.78 (1.60‑1.98) 2.12 (1.90‑2.35) 2.53 (2.26‑2.80) 2.90 (2.57‑3.21) 3.26 (2.88‑3.63) 3.65 (3.19‑4.08) 4.16 (3.59‑4.68) 4.62 (3.94‑5.25) 2-hr 1.42 (1.29‑1.57) 1.68 (1.53‑1.87) 2.09 (1.88‑2.31) 2.47 (2.23‑2.74) 2.96 (2.65‑3.28) 3.40 (3.02‑3.76) 3.83 (3.38‑4.26) 4.29 (3.75‑4.79) 4.90 (4.22‑5.51) 5.45 (4.63‑6.19) 3-hr 1.53 (1.39‑1.69) 1.80 (1.64‑2.00) 2.22 (2.01‑2.45) 2.63 (2.38‑2.90) 3.16 (2.84‑3.49) 3.65 (3.25‑4.03) 4.14 (3.66‑4.59) 4.67 (4.08‑5.20) 5.40 (4.64‑6.06) 6.06 (5.12‑6.87) 6-hr 1.93 (1.77‑2.12) 2.25 (2.06‑2.48) 2.72 (2.49‑2.99) 3.20 (2.91‑3.51) 3.83 (3.47‑4.20) 4.42 (3.96‑4.84) 5.01 (4.46‑5.52) 5.66 (4.97‑6.26) 6.57 (5.66‑7.31) 7.37 (6.25‑8.30) 12-hr 2.47 (2.28‑2.70) 2.89 (2.66‑3.15) 3.46 (3.18‑3.77) 4.03 (3.70‑4.38) 4.74 (4.34‑5.15) 5.37 (4.88‑5.84) 5.99 (5.40‑6.53) 6.62 (5.93‑7.24) 7.44 (6.59‑8.20) 8.14 (7.14‑9.06) 24-hr 2.78 (2.63‑2.96) 3.33 (3.14‑3.54) 4.08 (3.85‑4.34) 4.68 (4.41‑4.98) 5.51 (5.17‑5.86) 6.18 (5.78‑6.56) 6.87 (6.39‑7.29) 7.57 (7.00‑8.03) 8.51 (7.81‑9.05) 9.24 (8.42‑9.85) 2-day 3.34 (3.14‑3.56) 3.97 (3.74‑4.24) 4.83 (4.54‑5.15) 5.51 (5.18‑5.88) 6.44 (6.04‑6.87) 7.19 (6.71‑7.65) 7.94 (7.39‑8.47) 8.72 (8.08‑9.30) 9.75 (8.97‑10.4) 10.5 (9.64‑11.3) 3-day 3.60 (3.40‑3.83) 4.28 (4.04‑4.56) 5.16 (4.87‑5.49) 5.85 (5.52‑6.23) 6.80 (6.39‑7.23) 7.54 (7.07‑8.01) 8.28 (7.75‑8.81) 9.04 (8.42‑9.62) 10.0 (9.28‑10.7) 10.8 (9.93‑11.5) 4-day 3.87 (3.66‑4.11) 4.59 (4.34‑4.88) 5.49 (5.20‑5.83) 6.20 (5.87‑6.58) 7.15 (6.75‑7.58) 7.89 (7.44‑8.36) 8.63 (8.10‑9.15) 9.36 (8.76‑9.94) 10.3 (9.59‑11.0) 11.0 (10.2‑11.7) 7-day 4.67 (4.41‑4.96) 5.54 (5.22‑5.88) 6.61 (6.24‑7.03) 7.47 (7.04‑7.94) 8.64 (8.12‑9.17) 9.57 (8.96‑10.2) 10.5 (9.80‑11.1) 11.4 (10.6‑12.2) 12.7 (11.7‑13.5) 13.6 (12.5‑14.5) 10-day 5.38 (5.09‑5.72) 6.36 (6.01‑6.75) 7.52 (7.11‑7.98) 8.45 (7.98‑8.96) 9.72 (9.14‑10.3) 10.7 (10.0‑11.4) 11.7 (10.9‑12.4) 12.7 (11.8‑13.5) 14.0 (13.0‑14.9) 15.0 (13.8‑16.0) 20-day 7.41 (7.08‑7.80) 8.71 (8.31‑9.16) 10.1 (9.64‑10.6) 11.2 (10.7‑11.7) 12.6 (12.0‑13.2) 13.6 (13.0‑14.3) 14.6 (13.9‑15.4) 15.6 (14.8‑16.5) 16.9 (15.9‑17.8) 17.8 (16.6‑18.8) 30-day 9.09 (8.71‑9.50) 10.6 (10.2‑11.1) 12.2 (11.6‑12.7) 13.3 (12.7‑13.9) 14.8 (14.1‑15.4) 15.8 (15.1‑16.5) 16.8 (16.0‑17.6) 17.7 (16.9‑18.6) 18.9 (17.9‑19.8) 19.7 (18.6‑20.7) 45-day 11.6 (11.2‑12.1) 13.6 (13.1‑14.1) 15.3 (14.7‑15.9) 16.5 (15.9‑17.2) 18.0 (17.3‑18.7) 19.0 (18.3‑19.8) 20.0 (19.2‑20.8) 20.8 (19.9‑21.7) 21.8 (20.8‑22.8) 22.4 (21.4‑23.4) 60-day 14.0 (13.5‑14.6) 16.3 (15.7‑17.0) 18.2 (17.6‑19.0) 19.6 (18.9‑20.4) 21.2 (20.4‑22.1) 22.3 (21.5‑23.2) 23.3 (22.4‑24.3) 24.2 (23.2‑25.2) 25.2 (24.1‑26.3) 25.8 (24.7‑27.0) 1 Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. Back to Top PF graphical Precipitation Frequency Data Server https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?st=nc&sta=31... 1 of 4 5/30/2018, 11:51 AM