HomeMy WebLinkAboutNC0086291_More Information Received_20180427NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Mail the complete application to:
N. C. Department of Environment and Natural Resources
Division of Water Quality / NPDES Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
NPDES Permit Number INCO086291
If you are completing this form in computer use the TAB key or the up - down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type.
1. Contact Information:
Owner Name
Facility Name
Mailing Address
City
State / Zip Code
Telephone Number
Fax Number
e-mail Address
Town of Edenton
Beaver Hill WTP
P.O. Box 300
Edenton
NC / 27932
(252)482-7352
(252)482-7377
anne-marie.knighton@ncmail.net
2. Location of facility producing discharge:
Check here if same as above ❑
Street Address or State Road
City
State / Zip Code
County
Dr. Martin Luther King Jr. Avenue
Edenton
NC / 27932
Chowan
3. Operator Information:
Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the
Operator in Responsible Charge or ORC)
Name Town of Edenton
Mailing Address P.O. Box 300
City Edenton
State / Zip Code NC / 27932
Telephone Number (252)482-7352
Fax Number (252)5482-7377
4. Ownership Status:
Federal ❑ State ❑ Private ❑ Public
Page 1 of 4 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
5. Type of treatment plant:
❑ Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by
filtration and disinfection)
® Ion Exchange (Sodium Cycle Cationic ion exchange)
❑ Green Sand Filter (No sodium recharge)
❑ Membrane Technology (RO, nanofiltration)
Check here if the treatment process also uses a water softener ❑
6. Description of source water(s) (i.e. groundwater, surface water)
Groundwater
7. Describe the treatment process(es) for the raw water:
Raw water is aerated and treated using ion exchange. Once aerated water is softened and then
filtered (anion exchange) for removal of bromide and TOC. The piping is designed to bypass 25%
of the raw water and blend with softened water. The blend water flows to the anion exchange
vessels. Effluent is disinfected by gas chlorine prior to distribution system.
8. Describe the wastewater and the treatment process(es) for wastewater generated by the
facility:
Wastewater consists of a mixture of sodium chloride (brine) and treated water. No treatment
occurs prior to discharge.
9. Number of separate discharge points: I
Outfall Identification number(s) 002
10. Frequency of discharge: Continuous ❑ Intermittent
If intermittent:
Days per week discharge occurs: -7 Duration: 99 minutes per train
11. Plant design potable flowrate 0.542 MGD
Backwash or reject flow 0.035 MGD
12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including
latitude and longitude):
Filbert Creek
13. Please list all water treatment additives, including cleaning chemicals or disinfection
treatments, that have the potential to be discharged.
Alum / aluminum sulfate Yes No X
Page 2 of 4 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Iron sulfate / ferrous sulfate Yes No X
Fluoride Yes No X
Ammonia nitrogen / Chloramines Yes No X
Zinc -orthophosphate or sweetwater CP1236 Yes No X
List anv other additives below:
Sodium Chloride (brine)
14. Is this facility located on Indian country? (check one)
Yes ❑ No
15. Additional Information:
Provide a schematic of flow through the facility, include flow volumes at all points in
the water treatment process. The plan should show the point[s] of addition for
chemicals and all discharges routed to an outfall [including stormwater].
Solids Handling Plan
16. NEW Applicants
Information needed in addition to items 1-I5:
v New applicants are highly encouraged to contact a permit coordinator with the
NCDENR Customer Service Center.
Was the Customer Service Center contacted? ❑ Yes ❑ No
Analyses of source water collected
Engineering Alternative Analysis
Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a
water quality model.
17. Applicant Certification
I certify that I am familiar with the information contained in the application and that to the
best of my knowledge and belief such information is true, complete, and accurate.
Anne -Mane Knighton Town Mana;_er _
Print name of
Person Signing Title
Signature of Applicant Date
North Carolina Generali Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or cerl"fication in any application,
record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that
Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21
or regulations of the Environmental Management Commission implementing that Articie, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by
imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5
years, or both, for a similar offense.)
Page 3 of 4 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
L
ji
-1A P.7,yo
)io_)
Al
k
.4� CL
"0
Af
r- uj
0
Him
yv
E
(U
Ld
0
E
CL-
CY
CL C)
>
W -
M
Page 4 of 4 Version 5/2012
BEAVER HILL WTP
ION EXCHANGE
PROCESS SCHEMATIC
BEAVER
HILL WELL
0.288
MGD
0.576
0.288
MGD
MGD
AERATOR
BOSWELL
WELL
RETENTION
BASIN o
ti o
L 2- HIGH
SERVICE PUMPS
0
co m C) co
(1
N � N 71
O O
N
N
Q
CL
N
O O 0
NC�
N 0
0 O
C)O]
crO
ui
a
ION ION
CC) EXCHANGE EXCHANGE
CC)
0
3
0 SOFTENER SOFTENER
0
0
a
0
x
ppe ppb
O•�pp O• �O
BRINE
TANK
v
m p v
rno
�o
0
0 0
0.035
M o �
N 0
FILBERT'S
O o�
CREEK MGD
ION ION
EXCHANGE EXCHANGE
Opo Opo
O'�p0 O' X00
0.018
MGD
0.271 0.271
MGD MGD
0.542
DISTRIBUTION
MGD
SYSTEM
CL2