Loading...
HomeMy WebLinkAbout20061331 Ver 1_Emails_20061104DWQ 06-1331 Bucklin S/D Subject: DWQ 06-1331 Bucklin S/D From: Cynthia F Van Der Wiele <cynthia.vanderwiele@ncmail.net> Date: Sat, 04 Nov 2006 16:03:28 -0500 To: Ian McMillan <Ian.McMillan@ncmail.net> Ian: 1. The worksheet notes "medium ground cover". The specifications for level spreader lengths are 13' per cfs for thick ground cover and 100' per cfs for forested. They've gone with the 13'/cfs. I believe this is inadequate We don't have a middle ground on the old guidance. The new design guidance lowers the length for wider buffers... 2. Atypical detail (construction detail) of the level spreader was not included in the submittal. 3. *** What is the impervious cover of this development? The lots look small and I have concerns that they may be close to 30%. Was a break down sheet included in the PCN package?*** cynthia 1 of 1 11/6/2006 8:45 AM