Loading...
HomeMy WebLinkAboutNC0020354_More Information Received_19971222PO Box 3096 Cary, NC 27519 919-467-1239 December 19, 1997 Mr. Dave Goodrich, P.E. Supervisor, NPDES Unit Point Source Branch NCDENR-DWQ P.O. Box 29535 Raleigh, NC 27626-0535 )NNELL & ASSOCIATES, P.C. Re: Town of Pittsboro. North Carolina NGOo Zo 3s� WWTP-Influent Pump Station Flood Proofing MacConnell & nssociates, F.C. Project No.: 15401.00 Dear Mr. Goodrich: 1602 Sunrise Road Cary, NC 27513 Fax 919-319-6510 We are writing this letter to you regarding the above referenced project at the request of your colleague, Mr. Mark McIntire. In conjunction with the Town of Pittsboro, we are finalizing Contract Documents for a repair project involving the Town's wastewater treatment plant. During Hurricane Fran in 1996, several electrical and control components of the influent pump station were damaged from flood and lightning damage. In order to restore the influent pump station to pre -disaster condition and mitigate future hazards, this project was initiated. Examples of work to be completed during this project include: replacing a damaged variable frequency drive for the influent pumps, replacing .a damaged autodialer, moving and integrating all operator instrumentation and control interface above grade, providing heat tracing of piping in the dry pit, replacing an inoperable dry pit exhaust fan with a positive pressure ventilation fan, installing a fixed gas detection system, and replacing an inoperable bubbler with an ultrasonic level controller in the wet well. No change in the plant's permitted flow capacity or treatment process is proposed. In discussing the project scope with Mr. McIntire, he believed that an "Authorization to Construct (ATC)" permit would not be required from your office to proceed with implementing the project work. However, we do want to notify you that these repairs will be scheduled to bid during the first quarter of 1998. We hope that you concur with our and Mr. McIntire's assessment of the project; however, please notify us as soon as possible, if you do determine that an ATC permit is required for this project. Please do not hesitate to call either me or Ms. Shannon Mohr Thornburg at (919) 467-1239, if you should have questions and/or comments about this project. Thank you very much in advance for your assistance. Sincerely, ®(NTp - � � 9 ��.. Gary S. MacConnell, P.E.; / President L6 GZ rC`fJT SOUF)(,E- f3F ,NC cc: Mr. Walter Harris, Town of Pittsboro H Mr. John Poteat, Town of Pittsboro Mr. Mark McIntire, P.E., NCDENR-DWQ: Point Source Branch (NPDES Unit) Ms. Shannon Mohr Thornburg, MacConnell & Associates, P.C.