November 10, 2005
Mr. David Hughes
Town Manager
Town of Pittsboro
P.O. Box 759
Pittsboro, NC 27312
Subject: Compliance Evaluation Inspection
Town of Pittsboro WWTP
NPDES Permit No. N00020354
Chatham County
Dear Mr. Hughes:
On November 10, 2005 Mr. Christopher Wu of the Raleigh Regional Office conducted a
compliance evaluation inspection of the Town of Pittsboro's WWTP with the assistance of Mr.
Perry Dunn, back-up ORC of the facility, and Mr. Bill Davis, another operator of the facility.
Their help was appreciated as it facilitated the inspection process.
The following observations were made:
The Town of Pittsboro's WWTP is permitted to discharge at a rate of 0.75 MGD and
consists of a mechanical bar screen, 2 circular aeration basins that encompass two
circular secondary clarifiers, 3 tertiary filters, UV disinfection, effluent flow meter in a
parshall flume, a drum sludge thickener, and 2 aerobic digesters. The facility's permit is
due for its cyclical renewal. The application for renewal has already been submitted to
the Division.
2. The Pittsboro WWTP was issued an Authorization to Construct (AtoC) to begin a project
that would divert approximately 200,000 gpd to the 3M Company. This project would
include the addition of a 500,000 gallon EQ basin, 2 new 40 foot clarifiers, 2 new tertiary
filter cells, new UV facilities, and an effluent pump station with dual 350 gpm pumps for
reuse water transmission. Due to an underestimation of price, however, the Town of
Pittsboro is approximately $1 million short of meeting the financial requirements of the
project. Currently, the facility is awaiting the decision from Chatham County officials as
to whether or not the additional funding will be provided.
3. One of the aeration basins was experiencing a filamentous growth problem. Polymer has
been slowly added to it causing excessive foaming on the surface. Mr. Dunn expects the
foam to dissipate soon, as the other basin had a similar problem that was already
remedied.
One
NCarolina
North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service
Internet, h2o.enr.state.nc.us 3800 Barrett Drive Raleigh, NC 27699-1628 FAX (919) 571-4718 1-877-623-6748
An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper
Mr. David Hughes
Town of Pittsboro — NCO020354
4. There was a slight discrepancy in the August 2005 DMR submitted to the state. It
appears that data from August 3 was erroneously entered on August 1. Mr. Dunn stated
that he would amend the DMR and resubmit it to Central Files.
5. The influent storage sampler had a temperature of 5°C which is slightly outside the
mandated temperature range of 0°C — 4°C. Mild adjustments should be made to keep a
constant temperature.
6. The facility has a contract to have its sludge pumped, hauled, and land applied by
Synagro under permit WQ0011834. The Town lime stabilizes the sludge.
7. Environment 1 has been contracted to conduct the laboratory analyses for the facility.
8. The paperwork was well organized and easily accessible. Such order eased the
inspection process.
The overall conditions of the Town of Pittsboro WWTP are compliant with Division standards.
If you have any questions regarding the attached report or any of our findings, please contact
Christopher Wu at: (919) 791-4200 (or email: chris.wu@ncmail.net).
Cc: John Poteat, Town of Pittsboro
Perry Dunn, Town of Pittsboro
Bill Davis, Town of Pittsboro
Christopher Wu, RRO
Central Files
Sincerely,
Christop r Wu
Environmental Specialist
s0 91 AON
Permit: NC0020354 Owner - Facility: Pittsboro WWTP
Inspection Date: 11/10/2005 Inspection Type: Compliance Evaluation
Permit
Yes
No
NA
NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application?
■
❑
Q
❑
Is the facility as described in the permit?
■
Q
❑
❑
Are there any special conditions for the permit?
Q
■
❑
❑
Is access to the plant site restricted to the general public?
■
Q
❑
Q
Is the inspector granted access to all areas for inspection?
■
Q
❑
0
Comment. There are no special conditions for this permit.
Q
■
❑
Q
Operations & Maintenance
Yes
No
NA
NE
Is the plant generally clean with acceptable housekeeping?
■
0
❑
Q
Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable Solids, pH, DO, Sludge
V..
1,1„
KLA
K1=
Judge, and other that are applicable?
■
❑
Cl
Q
Comment:
Pump Station - Influent
Yes
No
NA
NE
Is the pump wet well free of bypass lines or structures?
■
Q
❑
❑
Is the wet well free of excessive grease?
■
❑
❑
Q
Are all pumps present?
■QQQ
❑
❑
❑
Are all pumps operable?
■
Q
❑
❑
Are float controls operable?
Q
❑
Q
■
Is SCADA telemetry available and operational?
Q
■
❑
Q
Is audible and visual alarm available and operational?
0
❑
❑
■
Comment: SCADA telemetry is not available.
❑
❑
Q
Is the site free of excessive buildup of solids in center well of circular clarifier?
Bar Screens
V..
1,1„
KLA
K1=
Type of bar screen
a Manual
❑
b.Mechanical
■
Are the bars adequately screening debris?
■
000
Is the screen free of excessive debris?
■
❑
❑
❑
Is disposal of screening in compliance?
■
❑
❑
❑
Is the unit in good condition?
■
❑
Q
❑
Comment:
Secondary Clarifier
Yes
No
NA NE
Is the clarifier free of black and odorous wastewater?
■
❑
❑
Q
Is the site free of excessive buildup of solids in center well of circular clarifier?
■
❑
Q
❑
Are weirs level?
■
❑
Q
Q
Is the site free of weir blockage?
■
❑
0
Q
Is the site free of evidence of short-circuiting?
■
Q
Q
❑
Is scum removal adequate?
■❑❑❑
Is the site free of excessive floating sludge?
■
Q
❑
❑
Is the drive unit operational?
■
❑
❑
Q
Is the return rate acceptable (low turbulence)?
■
Q
❑
❑
Is the overflow clear of excessive solids/pin floc?
■
Q
Q
❑
Is the sludge blanket level acceptable? (Approximately 114 of the sidewall depth)
■
Q
Q
Q
Comment:
Permit: NCO020354 Owner - Facility: Pittsboro WWTP
Inspection Date: 11/10/2005 Inspection Type: Compliance Evaluation
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1 0 to 3 0 mg/1)
Comment The DO level at the time of inspection was 5.03 mg/L
Filtration (High Rate Tertiary)
Type of operation
Is the filter media present?
Is the filter surface free of clogging?
Is the filter free of growth?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids and filter media?
Comment.
Disinfection - UV
Are extra UV bulbs available on site?
Are UV bulbs clean?
Is UV intensity adequate?
Is transmittance at or above designed level?
Is there a backup system on site?
Is effluent clear and free of solids?
Comment There is no back-up system on-site.
Laboratory
Are Feld parameters performed by certified personnel or laboratory?
Are all other parameters (excluding field parameters) performed by a certified lab?
Is the facility using a contract lab?
Is proper temperature set for sample storage (kept at 1 0 to 4.4 degrees Celsius)?
Incubator (Fecal Coliform) set to 44 5 degrees Celsius+/- 0 2 degrees?
Incubator (BOD) set to 20 0 degrees Celsius +/- 10 degrees?
Comment: Environment 1 is responsible for the laboratory analyses.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
X/. AI.- AIA -
■00❑
❑❑■❑
■000
■000
■00❑
0■00
❑■❑❑
Yes No NA NE
Cross flow
■❑0❑
■❑❑0
■❑00
■❑❑❑
■0❑0
■000
Yes No NA NE
■ ❑ ❑ ❑
0❑❑0
■0❑❑
0000
❑ ■ ❑ ❑
■ ❑ ❑ 0
Yes No NA NE
■ 0 ❑ ❑
■ ❑ ❑ ❑
■ ❑ 0 ❑
❑❑■❑
❑ ❑ ■ ❑
0❑■❑
Vo AI.. AIA AIC
■❑00
0000
■❑❑❑
0000
■000
■
Permit: NC0020354
Inspection Date: 11/10/2005
Record Keeping
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete do they include all permit parameters'?
Owner - Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment: There was one slight error on the DMR: results from August 3 were accidentally entered on August 1 Mr
Dunn stated that he would ammend the DMR and resubmit it
Influent Sampling
Is composite sampling flow proportional?
Is sample collected above side streams'?
Is proper volume collected?
Is the tubing clean?
Is proper temperature set for sample storage (kept at 1 0 to 4 4 degrees Celsius)?
Is sampling performed according to the permit?
Comment. Sampling is timed. The influent sample storage was at 5°C during the inspection
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
Is proper temperature set for sample storage (kept at 1 0 to 4.4 degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type representative)?
Comment:
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
Is the odor acceptable?
Is tankage available for properly waste sludge?
Comment.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
V. Ll.. AIA AIC
V.... LL. LIA LIr
V. Al.. LIA K-
V..n LI.. AIA K-
\/..w LL. LIA LITS
- - ■
❑
❑-
❑
■❑❑❑
■
0
❑
0
Permit: NC0020354
Inspection Date: 11/10/2005
Owner - Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
Solids Handling Equipment
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Comment:
90 91 fiON
Yes No NA NE
■nnn
nn■❑
❑n■0
■❑n❑