HomeMy WebLinkAboutNCG551085_Compliance Evaluation Inspection_20180614 "4,5,` ROY COOPER
(J „O{
MICHAEL S. REGAN
Secrctcrn
4 LINDA CULPEPPER
Water Resources h i erlin Dnectut
Enviionmental Quality.
June 14, 2018
Mr.Wade C.Davis RECEIVEPI®ENRJDWR
2525 Holly Lane 201
Durham,NC 27712 J U N O
Water Resources
on
Subject: Compliance Evaluation Inspection
PeP�lln9
Single Family Wastewater Treatment System
Permit No.NCG551085
Durham County
Dear Permittee:
On June 6,2018, Jeremiah Dow from the Raleigh Regional Office visited your single-family residence
(SFR)wastewater treatment system to evaluate compliance with the above permit to discharge
wastewater. The checked boxes below show what conditions were noted at your facility:
❑ In compliance: You are reminded to regularly maintain the chlorine disinfection and
dechlorination systems,have the effluent sampled once a year, and have the septic tank pumped
out every 3 to 5 years. Your good record of operation and meeting the permit requirements is
highly commended.
❑ Your home is improperly plumbed: Some of the wastewater discharges are going directly to
the environment without first passing through the treatment system. This must be corrected
immediately. Please submit a schedule to this office within 20 days of receipt of this letter that
states your plan for correcting this deficiency. The work is to be completed within the next 3
months.
❑ Disinfection: Your system is lacking disinfection, either chlorine tablets or a UV light system.
New rules put into place on August 1, 2007 require all SFR systems to have a means of
disinfection(and dechlorination when chlorine tablets are used to disinfect,if the system was
installed since that date). Since your system had no disinfection,the installation is to include a
chlorine tablet dispenser, a contact chamber capable of providing a minimum 30 minute contact
time, and another tablet dispenser that will hold dechlorination tablets. Please submit a schedule
to this office within 20 calendar days of receipt of this letter that states your plan for correcting
this deficiency.
Treatment tablets missing or are wrong kind: You are responsible for always having
chlorine tablets and dechlorination tablets (if a required part of your system) in place. They must
be the kind for wastewater treatment and not for swimming pools.
❑ Dechlorination: Your system was installed after August 1,2007, so must have a means of
dechlorination located downstream of the chlorinator and its contact chamber. See Disinfection
---- , .itlhin Compares`. ...
State of North Carolina I Environmental Quality I Water Resources I Raleigh Regional Office
1628 Mail service Center I Raleigh,North Carolina 27699-1628
919 791-4200
1.FTC.>w.
� a� ` ' �6 ' b; � 7-r ,7�a„ " ; 41•4451.70%
?Z, "^ ` 1.' d ` 7; ,4y; H ,
paragraph above. Please submit a schedule to this office within 20 calendar days of receipt of this
letter stating your plan for correcting this deficiency.
Ft Pumping the septic tank: The septic tank should be pumped out every 3 to 5 years. A
pumping company can check the status periodically and determine when pumping is required.
EL Failure to analyze the effluent: The effluent that is discharged from your system must be
analyzed once each year. See Part I(A) of your permit about his requirement. Make arrangements
for sampling to be carried out within the next-3 months, and submit resulis to this office within 3
weeks after the sampling has been done.
(l Locations of treatment units are unknown: Determine this and report to this office within
30 days of receipt of this letter with a sketch or map.
Other:
If you have questions or comments about this inspection or the requirements to take corrective action,
please contact Jeremiah Dow at 919-791-4200. Licensed plumbers should be used to make plumbing
changes within your home. Contractors for installing disinfection or other equipment may be found in the
Yellow Pages under Environmental Consultants.
yrely e
c.
' 4
S. Daniel Smith, Supervisor
Water Quality Regional Supervisor
Raleigh Regional Office
Attachments: Inspection Reports
cc: RRO/SWP Files
Charles Weaver,NPDES Permitting Unit
�
4Y=;="`otk Nm fso-��..�a4`ts°9T'i� �a�t^Pt�'t�a;�` � %.".731;7M-55 aj,.,.