HomeMy WebLinkAboutNC0046728_Issuance of Permit_20180613 - 4re ti ra ' June 13`h,2018 Mr. Mark Knight, EVP BestCo,Inc. 288 Mazeppa Road RECEIVED/DENR/DWR Mooresville,NC 28115 Subject: Zinc Permit Extension and CONSENT ORDER JUN.g 5 2018 BestCo, Inc. Water Resources Pretreatment Permit#0006 Permitting Section Dear Mr. Knight: Following our meeting today—and per your request for a 6-month permit extension on zinc in order to give BestCo time to get this parameter back into compliance—the following will be required: With temporary limits for Zinc 2.5 Lbs/day max. and 1.33 lbs/6 month avg. 1) An independent engineering study must be conducted within 60 days of this dated letter 2) Submission of the SOP for 1st rinse capture procedure to the Town of Mooresville. SOP should include how the 1' rinse is captured,as well as where and how the captured rinse is disposed of. Please submit manifest of hauled zinc waste(30 days) 3) A weekly production report for the Zycam products to ensure regular sample dates are representative 4) If zinc limits cannot be achieved by best management practice,other alternatives will be required via other actions(e.g. ion exchange, capturing and hauling,pretreatment, etc.) Any questions concerning these matters, please contact me at(704) 662-3051. Sincerely, Eric Brackett Environmental Compliance Town of Mooresville cc. Jamie Levis, WWTP Plant Manager Jeff Campbell, Environmental Compliance Supervisor ADMINISTRATIVE ORDER BY CONSENT BestCo BY:Mark Knight—6/13/201 Sign: /�� r/" Date: el/V(rc Town of Mooresville BY: Jeff Campbell —6/13/2018 Sign: tL9S Date: Is - t�� OF MOO40 s 41.1,.0 ej.4.---- ‘‘ co 'y4i - 00,,,,„„,-.o A E s v i t.tA.' July 1,2018 Mr. Mark Knight,EVP BestCo,Inc. PO Box 329 Mooresville, NC 28115 Subject: Transmittal Letter for Industrial User Pretreatment Permit(IUP 0006) Dear Mr.Knight: The Permit modification being issued to BestCo,Inc. (IUP# 0006) is enclosed. These permit modifications are being issued due to changed conditions and will be effective 7-1-2018.Any changes are issued pursuant to the requirements of North Carolina General Statute 143-215.1 and local Sewer Use Ordinance and the Pretreatment Program. Please read these permit modifications carefully. If any parts,measurement frequencies, or sampling requirements contained in this permit are unacceptable to you,you have the right to an adjudicatory hearing upon written request within (30)days following receipt of this letter.Unless such demand is made,this decision shall be final -- --- ----- —----- --- - ----- - -- ----- ----- --- --- ----and binding.All changes will be in the History Section and highlighted in yellow Sincerely, Ze......-L i 3,/t4-1-145----- Eric Brackett Environmental Compliance (Local Pretreatment Control Authority) cc. Jeff Campbell,Environmental Compliance Supervisor Jamie Levis,WWTP Plant Manager enclosure: IUP#0006 Town of Mooresville, RRWWTP Control Authority and/or Municipality PERMIT Industrial User Pretreatment Permit(IUP) To Discharge Wastewater Under the Industrial Pretreatment Program 0006 N/A IUP Number 40 CFR Category(if Applicable) In compliance with the provisions of North Carolina General Statute 143-215.1, any applicable federal categorical pretreatment regulations, all other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Control Authority and/or Municipality Sewer Use Ordinance. The following Industry, hereafter referred to by name or as the permittee: Industry name,permittee BestCo, Inc. Facility Located at Street Address 288 Mazeppa Road, PO Box 329 City Mooresville State,Zip North Carolina, 28115 is hereby authorized to discharge wastewater from the facility located at the above listed address into the sanitary sewer collection system and the wastewater treatment facility of the Control Authority and/or Municipality listed below: IUP Control Authority and/or Municipality WWTP name Rocky River Wastewater Treatment Plant NPDES Number NC0046728 WWTP Address 369 Johnson Dairy Road City,State,Zip Mooresville,North Carolina, 28115 in accordance with effluent limitations, monitoring requirements and all other conditions set forth in Parts I, II, and III of this Industrial User Pretreatment Permit(IUP). Effective date, this permit and the authorization to discharge shall become effective at midnight on this date July 1, 2018 Expiration date,this permit and the authorization to discharge shall expire at midnight on this date December 31 th, 2018 Date signed Envtr enta ompliance Supervisor-Jeff 0 /or ��Campbell Date signed Environmental Compliance Officer-Eric Brackett Industrial User Pretreatment Permit (IUP) PART I Specific Conditions IUP, PART I, OUTLINE: A.) IUP Basic Information B.) IUP Modification History C.) Authorization Statement D.) Description of Discharges E.) Schematic and Monitoring Locations F.) Effluent Limits &Monitoring Requirements G.) Definitions and Limit Page(s) notes A. IUP Basic Information: Receiving Control Authority&WWTP name POTW NPDES# Rocky River Wastewater Treatment Plant NC0046728 IUP Name IUP Number. BestCo, Inc. 0006 IUP Effective date Pipe Numbers list all regulated pipes. July 1, 2018 001 IUP Expiration date. IUP 40 CFR#(if applicable),or N/A December 31, 201S N/A B. IUP History. A Complete Permit History is required): Effective Renewal or Description of changes over previous HIP. Date Modification August 286, 1995 Modification Beacon has requested a look at surcharge to possibly help them with BOD problems.The town is looking into a surcharge system.The interim limits will build a data base to prepare the way to a limit for those charges and protect Beacon from possible fines. May 31, 1997 Modification Placed Beacon Sweets on pound-based limits for BOD&TSS.Also at this time Changed all permit pages to State format. November 30, 1998 Renewal Issued new permit.Higher BOD limits were the main issue. Surcharge is coming for at least BOD,TSS and possibly Oil&Grease. May 23,2000 Modification Revised pH monitoring and reporting requirements;pH limits max to 10 5 units and Description of IUP Discharge page October 16,2000 Modification Revised zinc levels to help Beacon with noncompliance.No over allocation with this modification.6-month average raised from.130mg/1 to.600mg/1. December 21,2000 Modification . Revised monitoring frequencies on BOD,TSS,Oil&Grease Composite samples to be collected daily,7 days/week March 22,2004 Modification Raised the daily max limit on Oil&Grease to 300 mg/1 from 150 mg/1 to help with non-compliance.Average remains the same at 100 mg/1.Raised the daily max limit on pH to 12.0 units. 2 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions May 23,2005 Modification The addition of an overflow sump and 2 additional pumps at the influent of the treatment facility to help with the incoming flow.Page 6 reflects the addition in the drawings.Low limit on pH from 6.0 to 6.5 August 19,2005 Modification Special conditions section dealing with certified operators. January 2,2006 Modification Changed flow from.300mgd to.250mgd and 6-month average from NJ .250mgd to.200mgd.This changes pounds allocation to 3648.75 DM and 2502 6-month average. May 10,2006 Modification Several changes have been implemented: NJ 1. Changed pH allowable limits from 6.5-12.0 to 6.0 to 12.5 per BestSweet,Inc.request. 2. Sample collection and storage increased to maintaining composite samples for 14 days in a refrigerator[NC DENR recommends that the pretreatment staff have access to industrial samples if violations should occur at the POTW] See section III. Special Conditions. 3. Changed cyanide detection limit from 0.002mg/1 to 0.005mg/1, since WWTP no longer has a cyanide limit on permit. 4. Changed reporting authority from Rickie Stutts to Pretreatment Staff.Rickie retired from the Town of Mooresville 12/31/05. 5. Fixed grammatical errors throughout permit. July 1,2007 Renewal Permit renewal with new streamlining changes. EB 1. Changed SIU sampling frequency to 1/quarter 2. Changed POTW sampling frequency to 1/six months 3. Dropped the 14-day sample collection&storage 4. Changed report due date from the 15th to the 20th February 1,2008 Modification 1. Changed required detection limit to recommended. EB 2. Changed Oil&Grease sampling to monthly. 3. Changed cyanide daily max.limits from 0.007 mg/1 to 0.015 mg/1 4. Changed cyanide monthly avg.limits from 0.005 mg/1 to 0.01 mg/1 January l st,2010 Modification 1. Added pH excursions from 6.0-12.0(see limits page)and# 14 in EB special conditions.Also,added pH excursion report sheet. 2. Removed ADMI Color sampling no longer on NPDES permit. 3 Changed zinc limits from mg/1 to lbs/day 4. Increased daily max.flow from 0.250 to 0.275 mgd July 1,2012 Renewal 1. Changed upper pH limit from 12.0 to 11.0 with pH excursions to EB 12.0. 2. Changed pH excursions to 3 thirty minutes in 24 hours 3. Changed zinc from mass based to mg/1 0.8 daily max&0.4 6/month average. 4. Added Pollutants of Concern for Long Term Monitoring Program 1/6 months. Name Change1. BestSweet changed name to BestCo.Nothing changed but the November 21,2013 name. EB 2. Removed Pollutants of Concern for LTMP from Permit. 3 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions August 15,2015 Modification Raised cyanide limit to 0.03 mg/1 daily max.from 0.015 and 6-month EB average to 0.02 from 0 01 to eliminate interference. July 1,2016 Modification Raised TSS limit to 507 lbs/day from 417 lbs/day and TSS 6/mo.average EB to 300 lbs.from 250 lbs. November 1,2016 Modification Gave temporary TSS limits due to higher production of calcium chews EB Temporary effective November 1,2016(900 lbs Daily Max&500 lbs 6/mo.Average) through January 1,2017 until we can evaluate new permit limits. January 1,2017 Modification Raised TSS limits due to higher production of calcium chews effective EB January 1,2017(900 lbs Daily Max&500 lbs 6/mo.Average). July 1,2017 Permit Renewal Permit renewed on current limits from last modification.Approved EB 12/15/2016 Also added COD Weekly(monitor only). May 1,2018 Modification Gave immediate temporary limits for Zinc due to new product(Zycam) EB massed based to 2.O lbs/day from May 1,2018 to June 30,2018.After evaluation new limits will be set and permit modified again. July 1,2018 Modification After evaluation of the previous modification the new limits for Zinc will be 2.5 lbs/day daily max.and 1.33 lbs/day for 6/month average.Zycam is a EB seasonal product and weekly sampling results should average below the six-month average limits.This will be from 7/1/18 thru 12/31/18.In December we will determine permanent Zinc limits,rog C Lb am o led Mme, 4 IUP Part 1 Section F: Receiving POTW name=> Mooresville IU name=> BestCo,Inc. Receiving POTW NPDES#_> NC0046728 IUP#_> 0006 Effluent Limits and Monitoring Requirements Effective date for these Limits=> 7/1/2018 Pipe#_> 001 Expiration date for these Limits=> 12/31/2018 40 CFR#_> N/A The Permittee may discharge from this specific if not applicable put N/A Pipe number according to these specific dates, THE LIMITS ON THIS PAGE ARE,(Check one below): LIMITS for ENTIRE permit period=> effluent limits, and monitoring requirements INTERIM Limits for period# 1 => INTERIM Limits for period#2=> FINAL Limits Page=> X Concentration Limits Mass Limits Monitoring Frequency Sample Recommended Collection Laboratory 6/Month 6 Month Method Detection Daily Max Average Units Daily Max Average Units By Industry By POTW (C or G) Level 1 Flow 0.275 0.200 MGD Continuous Record 2 BOD mg/1 3650 2500 lbs./day 1 /WEEK 1/6 months C 2 3 TSS mg/1 900 500 lbs./day 1 /WEEK 1/6 months C 5 4 Temperature Deg. C Deg.C 5 pH* 6.0— 11.0 Std.Units Std.Units Continuous 1/6 months 1 G OTHER PARAMETERS;Please List Alphabetically 6 Cadmium 0.005 0.003 mg/1 _ lbs./day 1/quarter _ 1/6 months C 0.001 7 Chromium 0.075 0.050 mg/1 lbs./day 1/quarter 1/6 months C0.01 8 Copper 0.500 0.200 mg/1 lbs./day 1/quarter 1/6 months C 0.01 9 Cyanide 0.03 0.02 mg/1 lbs./day 1/quarter 1/6 months G 0.01 10 Lead 0.048 0.032 mg/1 lbs./day 1/quarter 1/6 months C 0.005 11 Oil&Grease 300 200 mg/1 lbs./day 1/month 1/6 months G 5 12 Phosphorus monitor only mg/I lbs./day 1/quarter 1/6 months C 5 13 Nickel 0.075 0.050 mg/I lbs./day 1/quarter 1/6 months C _ 0.005 14 Nitrogen, 10 7.5 mg/1 lbs./day 1/quarter 1/6 months C 0.1 ammonia 15 Zinc mg/1 hg's _ LA lbs./day S0 k IB1EI. 1/6 months C 0.005 16 COD monitor only mg/1 lbs./day 1 /WEEK 1/6 months G 17 COD same sample as BOD 18 19 20 21 *pH—(3) 30 min. excursions from permitted limits allowed within a 24-hr. period; (Any spike below 5.0 or above 12 5, no matter how brief a time, is considered a violation) 7 IUP Synopsis A. IUP Basic Information Receiving POTW name POTW NPDES# Rocky River Wastewater Treatment Plant NC0046728 RIP name: IUP Number. BestCo, INC. 0006 IUP Effective date: Pipe Numbers list all regulated pipes. July 1st,2018 001 IUP expiration date. IUP 40 CFR#,if applicable December 31,2018 N/A B. IUP Survey&Application form Attach a completed copy of the Industrial User Wastewater Survey& Application Form(see appendix 6-A) C. IU Inspection form Attach a copy of an Industrial User Inspection Form(see chapter 7) completed by the Control Authority within the past 12 months. D. RATIONALE FOR LIMITATIONS: As listed on the IUP Limits Page(s), PART I, Section F of the IUP. RATIONALE#1: Review of IU Monitoring Data, with no Over Allocation situation: The following pollutants were assigned numerical limits in this IUP based on a review of monitoring data for the permittee to determine what ranges of concentrations are currently being discharged. To account for sample variability a factor was applied to the monitoring data to determine the permit limit. Permit limits assigned by the Local IUP Control Authority can not result in an Over Allocation situation for any pollutants. Changed Zinc limits due to change in production. They have', 'added Zycam Effective 7/1/2018 to 12/31/2018. New limits will be determined before December 31, 2018 1 Workbook Name : 2013AllocationTable rev 6 -7-1-2018 History, Worksheet Name: Atrinted:6/14/2018, 10:03 AM Page 1 of 4 Allocation Table Spreadsheet Instructions Headworks last approved 01/14/14 1)Applicable Values should be entered in the Heavy Bordered cells Rest of worksheet is protected,password is Allocation Table updated 07/01/18 2)Formulas are discussed in the Comprehensive Guidance,Chapter 6,Section C Permits last modified 07/01/18 3)HWA and AT worksheets in this workbook are linked Pollutant Names,MAHLs,Basis,and Uncontrollable load in this AT worksheet are automatically entered from the HWA spreadsheet This includes pollutant names in columns AT through BK , Pores=,Rocky River WWTP NPDES#=> NC0046728 FLOW BOD TSS Industry Type Renewal Modification Date Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe of Effective Effective Permit Conc Load Conc Load Count (please Itst alphabeucly) number number Industry Date Date Expires MGD gal/day mg/1 lbs/day t, L/ lbs/day 1 Bestco,Inc. 0006/01 0001 Candy 07/01/17 07/01/18 06/30/22 0.2000 200,000 1500 00 2502.00 540 00 900 72 2 Carolina Beverage Group,LLC 0017/01 0001 Energy D 01/01/14 07/01/18 12/31/18 0.7000 700,000 1071 00 5225.00 107 625 25 3 Niagra Bottling LLC 0018/01 0001 Water 01/01/17 10/15/15 12/31/21 0 3000 300,000 250 625 50 4 5 6 7 8 9 10 , 1 Column Totals=> 1 20001 1,200,000 t 83531 1 15261 Basis=> NPDES Design Design MAHL from HWA(lbs/day)=> NPDES Permitted Flow=> 7 5000 20204 21455 Uncontrollable Loading(lbs/day)=> 2 9811 6738 9348 Total Allowable for Industry(MAIL)(lbs/day)_> 4 5189 13466 12106 Total Permitted to Industry(lbs/day)=> 1.2000 8353 1526 MAIL left(lbs/day)_> 3.3189 5113 10580 Percent Allow Ind (MAIL)still available(%)=> 73 4% 38 0% 87 4% Percent MARL still available(%)=> 44 3% 25 3% 49.3% 5 Percent MARL(lbs/day)=> 0 3750 1010 1073 HWA AT Revised•November 2005 Workbook Name : 2013AllocationTable rev 6 - 7-1-2018 History, Worksheet Name: Afrinted 6/14/2018, 10.03 AM Page 2 of 4 Allocation Table Headworks last approved. 01/14/14 Allocation Table updated 07/01/18 Permits last modified: 07/01/18 POTw=>Rocky River WWTP NPOES4 > NC0046728 Ammonia Arsenic Cadmium Chromium Copper Cyanide Industry Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc Load Cone Load Conc Load Conc Load Conc. Load Conc. Load Count (please hst alphabet cly) number number mg/1 lbs/day mg/l lbs/day mg/I lbs/day mg/1 lbs/day mg/I lbs/da m• lbs/day 1 Bestco,Inc 0006/01 0001 7 50 12 51 0 0030 0 0050 0.0500 0.0834 0 2000 0 3336 0.0300 0 0500 2 Carolina Bevera:e Grim's,LLC 0017/01 0001 7 50 43 79- 1 0030 0 0175 0.0500 0 2919 1 2000 1 1676 0 0100 0 0584 3 iagra Bottling LLC 0018/01 0001 4 --- 5 --- 6 7 8 --- -' 9 --- 10 Column Totals=> 56 0 0000 0 0225 0.3753 1 0 1084 Sludge Sludge Basis=> Design Ceiling Stream Std Stream Std Ceiling NPDES MAHL from HWA(lbs/day)=> 1438 65 0 1066 0 1796 8.2311 3 2128 0 4345 Uncontrollable Loading(lbs/day)_> 673.77 0 0671 0 0746 0.0870 0 9075 0 0646 Total Allowable for Industry(MAIL)(lbs/day)_> 764 88 0 0394 0 1050 8 1441 2 3054 0 3698 Total Permitted to Industry(lbs/day)=> 56 30 0 0000 0 0225 0 3753 1 5012 0 1084 MAIL left(lbs/day)_> 708 58 0 0394 0 0825 7 7688 0 8042 0.2614 Percent Allow.Ind (MAIL)still available(%)_> 92 6% 100.0% 78 6% 95 4% 34.9% 70 7% Percent MARL still available(%)=> 49 3% 37 0% 45 9% 94 4% 25 0% 60 2% 5 Percent MAHL(lbs/day)_> 71 93 0 0053 . 0 0090 0 4116 0 1606 0.0217 HWA AT Revised November 2005 Workbook Name : 2013AllocationTable rev 6 - 7-1-2018 History, Worksheet Name: A'f rinted 6/14/2018, 10 03 AM Page 3 of 4 Allocation Table Headworks last approved 01/14/14 Allocation Table updated 07/01/18 Permits last modified. 07/01/18 Poriv=>Rocky River WWTP NPDES#I=> NC0046728 Lead Mercury Molybdenum Nickel Selenium Silver Industry Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc Load Conc Load Conc Load Conc Load Cone Load Conc Load Count (please hstalphabehcly) number number mg/I lbs/day mg/I lbs/day mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day 1 Bestco,Inc 0006/01 0001 0 0320 0 0534 0.0500 0.0834 2 Carolina Beverage Group,LLC 0017/01 0001 0 0320 0 1868 0 0500 0 2919 _ 3 Niagra Bottling LLC 0018/01 0001 4 11 11 115 6 7 8 _ 9 10 Column Totals=> 0 2402 i 0.000000n 0 0000 0 3753 0 0000 0 0000 Sludge Sludge Ceiling Sludge AS/Nit/TF Basis=> Ceiling NPDES HASL Ceiling Stream Std inhibition MARL from HWA(lbs/day)=> 0 8805 0 017510 0 9428 0.6394 0 2963 6 7346 Uncontrollable Loading(lbs/day)=> 0 0646 0 004227 0 1566 0 0920 0 1343 0.0671 Total Allowable for Industry(MAIL)(lbs/day)_> 0 8159 0 013283 0 7862 0 5474 0 1621 6 6674 Total Permitted to Industry(lbs/day)=> 0 2402 0 000000 0.0000 0 3753 0 0000 0 0000 MAIL left(lbs/day)=> 0 5757 0 013283 0.7862 0 1721 0 1621 6 6674 Percent Allow Ind (MAIL)still available(%)=> 70 6% 100 0% 100 0% 31 4% 100 0% 100 0% Percent MAHL still available(%)_> 65 4% 75 9% 83.4% 26.9% 54 7% 99 0% 5 Percent MAHL(lbs/day)=> 0 0440 0 000875 0 0471 0 0320 0.0148 0 3367 HWA AT Revlsed:November 2005 Workbook Name : 2013AllocationTable rev 6 - 7-1-2018 History, Worksheet Name: Atrinted 6/14/2018, 10:03 AM Page 4 of 4 Allocation Table Headworks last approved 01/14/14 Allocation Table updated 07/01/18 Permits last modified 07/01/18 Pam.,Rocky River WWTP NPDES#k> NC0046728 Zinc Total Nitrogen Total Phos. Industry Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc. Load Conc Load Conc. Load Count (please list alphabebcly) number number mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day 1 Bestco,Inc 0006/01 0001 0 8000 1 3344 2 Carolina Beverage Group,LLC 0017/01 0001 0 2000 1 1676 3 Niagra Bottling LLC 0018/01 0001 4 5 6 8 9 10 Column Totals=> I 2 5020 0 00 0 00 Sludge Basis=> Ceiling Design MAHL from HWA(lbs/day)=> 8 2956 347 15 Uncontrollable Loading(lbs/day)=> 3 5479 45 56 Total Allowable for Industry(MAIL)(lbs/day)_> 4 7478 301 60 Total Permitted to Industry(lbs/day)=> 2 5020 0 00 0 00 MAIL left(lbs/day)_> 2 2458 301.60 Percent Allow.Ind (MAIL)still available(%)=> 47.3% ####### 100 0% Percent MAHL still available(%)_> 27.1 % ####### 86 9% 5 Percent MAHL(lbs/day)=> 0 4148 17 3576 HWA AT Revised•November 2005 e F of MOoq4. O / `o 'wt., 'c I. 5S `` " 'o `y 767$."+• G 0 4esvio-6. May 9,2018 BestCo Inc. Mr.Rickie Stutts Pretreatment Operator Mr. Stutts, Thank you,Mr., Stutts for assisting us while we performed our 2018 Inspection. During our inspection we noted that all deficiencies from our previous inspection have been completed.Listed below are our matters of concern? 1 —Record effluent temperature when taking samples. 2—Clean or change pick-up tubing twice a month. 3—Permit has been modified and approved by DWQ for temporary limit for zinc to avoid violations until June 30th. New limits will be established and will go into effect July 1St, 2018. Lane,Jeff and I were very impressed on the strides you make at your facility and the preventative measures you have made to help eliminate any impact to our wastewater treatment plant. Any questions concerning these matters,please contact me at(704)662-3051. Sincerely, Eric Brackett Environmental Compliance Officer Town of Mooresville cc. Jeff Campbell, Environmental Compliance Supervisor Lane Cory,Environmental Compliance SIU INSPECTION FORM PART H-Plant Tour Section B-PRETREATMENT SYSTEM Ask the operator to describe pretreatment system. 1. Does operator seem knowledgeable about the system? YES/NO Comments: 2. Are all units operational? YES/NO(2 pumps in silo's 1 primary 1 secondary) 3. How often does operator/maintenance person check system? Daily 4. Is there an operator for each shift? YES/NO 5. How and when is sludge disposed of? N/A 6. Is there a schedule for preventative maintenance? YES/NO Comments: Maintenance checks PT system on off shifts as well as alarms with any failure to system. PART II-Plant Tour Section C-SAMPLING POINT(S)AND FLOW MEASUREMENT (Collect a sample if desired.) 1. Does an outside lab complete sampling? YES/NO If yes,name of lab. Statesville Analytical/Pace 2. If industry completes sampling,ask the industry representative to describe sampling procedures. Comments: N/A • 3. Is flow measurement equipment operational? YES/NO Comments: Copy of results with monthly report. 4. Is there a calibration log for the flow meter? YES /NO Comments: Quarterly Calibration ISI in Mathews,NC Comments: pH weekly by operator and quarterly by contract(ISI) PART III-EXIT INTERVIEW Review monitoring records and other SIU records required by IUP. 1. Are files well organized? YES/NO Comments: 2. Are sample collection/chain-of-custody forms filled out properly? YES/NO Comments: 3. Does results in files agree with reports sent to POTW? YES/NO Comments: 4. Who has authority to shut down production should a spill or slug discharge occur? Engineering,V.P. Operator 5. How does SIU inform employees of whom to call at POTW in case of spill/slug? Call&email POTW. e-mail Pretreatment Coordinator and call during normal business hours. If slug/spill plan is already required by POTW,review procedures. 6. Is SIU implementing slug/spill plan? YES/NO Comments: Updated every permit cycle unless change in personnel Comments: (5)POTW e-mail wwtpalerts@ci.mooresville.nc.us (980-722-6256) INSPECTION RESULTS Slug/Spill Control Plan Needed? YES/NO Comments, Required or Recommended Actions: Updated with last permit cycle(2017) BestCo is very conscious of the PT system and pays for a certified operator. Signature of Inspector(s) ft Date: 5/9/2018 EB ' % Date: 5/9/2018 LC 6. °t"441°1 -() m441°1 () Date: 3/16/2017 JC Title SIU Inspection Form File name: COMP INSP App 7-D Revision data: August 1, 1994 Page 2 SIU INSPECTION FORM Name of Industry: BestCo,Inc. IUP#0006 Address Of Industry: 288 Mazeppa Road IUP Expiration Date: P.O.Box 329 June 30th,2022 Mooresville,NC 28115 Industry Representatives: Title Rickie Stutts Pretreatment Operator POTW Representatives: Title Eric Brackett Environmental Compliance Lane Cory Environmental Compliance Jeff Campbell Environmental Compliance Date of Inspection: 5/9/2018 Time Of Inspection: 8:30 am n/pm Purpose of Inspection: Annual X Other(Describe) POTW to which IU discharges Rocky River WWTP NPDES# NC0046728 Is SIU currently in SNC? No If yes,for what? PART I-INITIAL INTERVIEW Has anything changed since the last inspection or IUP application in the following: COMMENTS Product YES /NO Gummy Bear Line Running and Added Zycam Raw materials used YES/NO Added powdered sugar Manufacturing processes YES/NO No Change Categorical, if applicable YES/NO N/A Production rate YES/NO Upgraded Line 7 and line 8 is now in production. Number of employees YES/NO 430 Total 268 Full Time less(17)same as last year Number of shifts YES/NO 3 Comments: 24/7 except for slow months in the winter. PART II-PLANT TOUR-Visit all areas where wastewater is generated or where there are drains to the POTW. Plant Tour Section A-PRODUCTION AND STORAGE AREAS 1. Are there floor drains in the production area? YES/NO Where do they go? Pretreatment Area 2. Are production areas diked,contained,or otherwise constructed in such a way as to prevent harm to the WWTP,especially from spills or slugs? YES/NO Comments: curbed area to sump pump to totes 3. Are there floor drains in the storage area? YES/NO Where do they go? N/A 4. Are storage tanks and areas diked,contained,or otherwise constructed in such a way as to prevent harm to the WWTP,especially from spills or slugs? YES/NO Comments: 5. Are process and storage tanks and pipes labeled? YES/NO 6. How are off-spec raw materials,and products disposed of? Farmers,Landfill,Recycle,Composting Hauled by CTW to Wallace Farm for Composting,Solid to landfill by Republic(Manifest on site) 7. When is the production area cleaned? Continuous(captured and hauled off in totes to reduce BOD) 8. Is the wastewater from cleaning the production area discharged to the POTW? YES/NO 9. What non-process wastewaters are discharged to POTW? Sewer,Bathrooms Comments:(8)—1-all wastewater from cleaning equipment goes thru pretreatment system. 2-All floor cleaning liquid is collected in a tote and hauled off site. Title. SIU Inspection Form File name: COMP.!NSP App 7-D Revision data• August 1,1994 Page I