Loading...
HomeMy WebLinkAboutNCG030694_NOI Application_20180614Environmental Quality Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCG030000 FOR AGENCY USE ONLY Date Received Year Dlonth Day Certifcateofcovera e N Check a Amount Penrtit Assigned to NOTICE OF INTENT I^ G- 0 20 / National Pollutant Discharge Elimination System application for coverage under General Permit NCG030000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) 335 Rolling, Drawing, and Extruding of Nonferrous Metals SIC 3398 Metal Heat Treating ECEI RECEIVED SIC 34 Fabricated Metal Products ' `C �/ED SIC 35 Industrial and Commercial Machinery JUN O 6 SIC 36 Electronic and Other Electrical Equipment 2018 SIC 37 Transportation Equipment DENR-LAND QUALITY SIC 38 Measuring, Analyzing, and Controlling Instruments STORMWATER PERMITTING 1 For questions, please contact the DEMLR Regional Office for your area. See page 4. (Please print or type) 1) Mailing address of owner(perator address to which all permit correspondence will be mailed): Name LLFlex, LLC Street Address City Telephone No. 1225 West Burnett Avenue Louisville 502 636-8471 2) Location of facility producing discharge: Facility Name Facility Contact Street Address City County Telephone No. Email State Kir ZIP Code 40210 Fax: N/A Oracle Flexible Packaging, Inc. (Former) Cunningham Plant Bill Whalen 1300 Cunningham Avenue Winston-Salem State NC ZIP Code 27107 Forsyth 248 214-2222 Fax: N/A BillWhalen@oraclepkg.com 3) Physical Location Information: go.aa 97� Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). when travel north on US -52, Take exit towards S Research Parkway, Keep right at fork to merge onto S Research parkway, continue take first right onto Bruce street then immediate right onto Diggs Blvd, Diggs turns into Vargrave Street, then turn left onto Cunningham Street which leads to facility. (A copy of a county map or USGS quad sheet with the facility clearly located must be submitted with this application.) 4) Latitude 36° 04'33" N Longitude 80° 13'38'W (deg, min, sec) 5) This NPDES Permit Application applies to which of the following: E] New or Proposed Facility Date operation is to begin 0✓ Existing Page 1 of 4 SWU-218-071408 Last revised 72114 NCG030000 N.O.I 6) Standard Industrial Classification: Provide the 4 -digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility. SIC Code: 3 3 5 3 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: The facility is currently inactive, The facility formerly manufactured aluminum foil of various gauges from aluminum ingots. The foil was used for packaging tobacco, food, and pharmaceutical products. 8) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? -5 - What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater discharaes and uo in? An unnamed tributary to Salem Creak Receiving water classification: Gass c Is this a 303(d) listed stream? Yes Hasa TMDL been approved for this watershed? Yes, updated In 2018 the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). city ofwinston-salemMunicipal Storm Sewers List discharge points (outfalls) that convey discharge from the site (both on-site and off-site) and location coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan. Stormwater Outfall No. loom Latitude (degrees/minutes/seconds): wo4,4w N Longitude (degrees/minutes/seconds): SW 13'42- W Stormwater Outfall No. s000tl¢ Latitude (degrees/minutes/seconds): wo4'38* N Longitude (degrees/minutes/seconds): 80' _13'36" W Stormwater Outfall No. soo.00s Latitude (degrees/minutes/seconds): as° 04'31" N Longitude (degrees/minutes/seconds): so• 13* 33" W Stormwater Outfall No. soon Latitude (degrees/minutes/seconds): 30.04.31" N Longitude (degrees/minutes/seconds): 80.13' 33" W Stormwater Outfall No. 200405 Latitude (degrees/minutes/seconds): 30.04' 2g" N Longitude (degrees/minutes/seconds): 80.13' 34" W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude (degrees/minutes/seconds): W 9) Does this facility have any other NPDES permits? 9 No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: Page 2of4 SWU-218-071408 Last revised 7/2114 NCG030000 N.O.I. 10) Does this facility have any Non -Discharge permits (ex: recycle permit)? ❑ No 19 Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: Permit WOOOOO965 11) Does this facility employ any best management practices for stormwater control? ❑ No 4 Yes (Show any structural BMPs on the site diagram.) If yes, please briefly describe: The site is being cleaned up and is vacant. Other stormwater practices include monitoring, spill controls for bulk oil areas, SPCC in place, use of a SWPPP, routine inspections 12) Does this facility have a Stormwater Pollution Prevention Plan? ❑ No 11 Yes If yes, when was it implemented? November2014 13) Are vehicle maintenance activities occurring at this facility? S No ❑ Yes 14) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? 9 No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? 4 No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? d No ❑ Yes d) Is hazardous waste stored in the 100 -year flood plain? IR No ❑ Yes If yes, include information to demonstrate protection from flooding. e) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 15) Certification: North Carolina General Statute 143-215.66 (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact In a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders Inaccurate any recording or monitoring device or method required to be Page 3 of 4 SWU-218-071408 Last revised 7014 NCG030000 N.O.I. operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a rine not to exceed ten thousand dollars ($10,000). 1 hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bill Whalen Title: Chief Financial Officer 6ho ave - (Signature of Applicant) (Date Signed) This Notice of Intent must be accompanied by a check or money order for $100.00, made payable to: NCDEQ Page 4 of 4 SWU-218-071408 Last revised 712/14 NCG030000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: Check for $100 made payable to NCDEQ. O This completed application and all supporting documents. A site diagram showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater management structures, (c) location of stormwater outfalls corresponding to the drainage areas, (d) runoff conveyance features, (e) areas where materials are stored, (f) impervious areas, (g) site property lines. 91 Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map. Mail the entire package to: DEMLR - Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee coverage under the General Permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 5 SWU-218-071408 Last revised 7!2114 hart '� hickman Via U. S. Mail SMARTER ENVIRONMENTAL SOLUTIONS June 1, 2018 NC DEMLR Stormwater Program Department of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Re: Notice of Intent — NCG030000 Oracle Flexible Packaging, Inc. (Former) Cunningham Plant 1300 Cunningham Avenue Winston-Salem, Forsyth County H&H Project No. ORA -015 Dear Madam/Sir: On behalf of LL Flex, LLC, Hart & Hickman, P.C. (H&H) is submitting the enclosed Notice of Intent (NOI) for industrial stormwater permit coverage under General Permit NCG030000 for the former Oracle Flexible Packing, Inc. (Oracle) Cummingham Plant. The property is not owned by LL Flex, LLC or Oracle. The site was previously utilized for manufacturing of aluminum foil of various gauges from aluminum ingots. The facility has been inactive since 2016 when the Alpha Aluminum (Alpha) vacated the site suddenly due to financial problems. Alpha was responsible for the prior stormwater permit (NCG030239). However, because Alpha was subleasing from Oracle, the responsibility to maintain a stormwater permit may rest with Oracle. In addition, the site does not appear to currently qualify for a No Exposure Certification. Therefore, Oracle is submitting this NOI for a new industrial stormwater permit. Oracle does not plan to use the facility. Should you have any questions or need any additional information, please feel free to contact me. Sincerely, Hart & Hickman, PC 11101e4jX611_ Matt Bramblett, PE Principal Enclosure - including $100 check cc: Viktoriya Khvorostovska, Oracle (via email) Tom Griffin, Parker Poe (via email) RECEIVED JUN 06 2098 DENR-LAND QUALITY STORMWATER PERMITTING 2923 South Tryon Street, Suite 100 3921 Sunset Ridge Rd, Suite 301 Charlotte, NC 28203 Raleigh, NC 27607 www.harthickman.com 704.586.0007 main 919.847.4241 main SD'OSS -0Ol ♦� `�\ 'moi DISCRIPTION 1 AST TANK FARM 2 DRUMS / TOTES STORAGE AREA BUILDING 16 3 OIL CELLAR (BASEMENT OF BUILDING 16) 4 �t .li 5 f( t` 6 DRUMS / TOTES / OIL CATCH TRAY BUILDING 17 i� IF «s. ' v ID0 002 DRAINS TOWARD DA = 113,263 sf 7 �y of �1l�l�lt*I if IMP = 93% _ — o D.1 = 205,526 sf I11P = 81 1 4 . `'^j` 4 : i_ - " • Outfalls SDO-006 and SDO-007 are I i ��— Non -Industrial Outfalls as their drainage ares is limited to Employee Parking. a DA = 188,334 sf _ • IMP =100% L '.. :•l \ SUO-1103 `' *00 4— T'_L — — '— — _ ---- �' I �DA=30,766sf "+ SUO-003 �. ' ° I 111' 100% �=34f . •"T'^ • p� IMP = 58°/„ O—f–__•. -��' _ ._y{� � �. y �+ —• FORMER SOLVEN i TANK FA M tMER PROPANE TANK AREA LEGEND SITE PROPERTY BOUNDARY T; ; rrrrrr RAILROAD TRACKS CHAINLINK FENCE SANITARY SEWER LINE — — — — DRAINAGE AREA BOUNDARY SANITARY SEWER MANHOLE ® STORMWATER CATCH BASIN STORMWATER DRAIN LINE ail i OIL STORAGE AREA & ID DRAINAGE DIRECTION SITE ID DISCRIPTION 1 AST TANK FARM 2 DRUMS / TOTES STORAGE AREA BUILDING 16 3 OIL CELLAR (BASEMENT OF BUILDING 16) 4 LUBRICATION DISPENSERS STATION 1 AND GRINDERS BUILDING 16 5 TRANSFORMER STATION 6 DRUMS / TOTES / OIL CATCH TRAY BUILDING 17 7 MISC. PAINTS BUILDING 17 8 OIL CELLAR (BASEMENT OF BUILDING 22) 9 MISC. DRUMS AND BUCKETS OF OIL / LUBRICANTS 10 OIL FILTERING TANKS BUILDING 30 / ROLLING MILL 19 11 FINISHED GOODS/ RAW MATERIALS BUILDING 27 12 LUBRICATION DISPENSERS STATION 2 AND DRUM STORAGE BUILDING 27 13 FILER ROOM DRUM /TOTE AREA 14 CONTRACTOR AREA DRUMS 15 DROSS STORAGE AREA 16 ROLL OFF STORAGE AREA (PALLETS / METALS) 17 MISC. PALLETS/ EQUIPMENT AREA a APPROXIMATE 0 150 300 SCALE IN FEET SITE LAYOUT oE. FORMER ORACLE FLEXIBLE PACKAGING 1300 CUNNINGHAM AVENUE WINSTON—SALEM, NORTH CAROLINA • hart h i c k m a n 2923 South Tryon Street -Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(1) SMARTER ENVIRONMENTAL SOLUTIONS Incense # C-1269 / #C-245 Geology DATE: 6-1-18 JOB NO. ORA -015 REVISION NO. 0 FIGURE NO. 2