HomeMy WebLinkAboutNC0085359_Compliance Evaluation Inspection_20180525N -Z
Water Resources
Eh ViAQNMEHTAL QVALiTV
May 25, 2018
Mr. Edward Goscicki, PE
Union County Department of Public Works
500 North Main Street, Suite 400
Monroe, NC 28112
SUBJECT: Compliance Evaluation Inspection
12 Mile Creek WWTP
NPDES Permit #NC0085359
Union County, NC
Dear Mr. Goscicki:
ROY C OOPE1R
Gayff var
A ICHNEL S_ REGAN
Secrelan.
LLVDA CLTLPEPPER
MRF1M D&gCfVr
On April 9, 2018, Roberto Scheller of this Office conducted an inspection at the subject facility. This inspection was
conducted as a Compliance Evaluation Inspection (CEI) to insure compliance with permit requirements and
conditions. During the subject inspection it was noted that a large raft of debris had acclimated at the inlet of
oxidation ditches #1 and #2. The raft is causing an odor nuisance and vector attraction and should be removed.
Other than this the facility appeared to be well operated and maintained. We wish to thank you and the operating
staff for assistance regarding this inspection.
The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to
contact Roberto Scheller, of the Mooresville Regional Office, at 704-663-1699 or roberto.scheller@ncdenr.gov.
Sincerely,
DocuSigned by:
A14CC681AF27425...
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Mooresville Regional Office
Enclosure: Inspection Report
cc: ORC - jothanjordan@unionconc.gov
State of North Carolina I Environmental Quality I Water Resources
610 East Center Avenue, Suite 301, Mooresville, NC 28115
704-663-1699
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 15 I 3 I NCO085359 111 12 I 18/05/10 I17 18 I S i 19 LG] i 201 I
211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
67 70I�_71 I 72 Lr] 73I i74 751 I I I 1 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
09:49AM 18/05/10
15/01/01
Twelve Mile Creek WWTP
8299 Kensington Dr
Exit Time/Date
Permit Expiration Date
Waxhaw NC 28173
01:52PM 18/05/10
19/12/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Jonathan Brian Jordan/ORC/704-562-4542/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Edward Goscicki,500 N Main St -Ste 500 Monroe NC 281124730/Executive
Director/704-296-4212/7042964232 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
DocuSigned by:
Roberto Scheller MRO WQ//252-946-6481/ 5/23/2018
E 43E_
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger MRO WQ//704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
IA14CC681AF27425...
5/29/2018
Page#
NPDES yr/mo/day Inspection Type
NCO085359 111 121 18/05/10 1 17 18 JCJ
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit: NCO085359
Owner - Facility: Twelve Mile Creek WWTP
Are records kept and maintained as required by the permit?
0
❑
Inspection Date: 05/10/2018
Inspection Type: Compliance Evaluation
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the
permittee submitted a new ❑
❑
0
❑
application?
0
❑
❑
❑
Is the facility as described in the permit?
❑
0
❑
❑
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: Current permit expires on December 31,
2019. Construction for plant upgrades was
on-going at time of inspectioin. Construction is done under Authorization to Construct
44nococnnn-7
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
❑
❑
❑
Is a copy of the current NPDES permit available on site?
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
Comment: The A to C increases permitted capacity from 6.0 MGD to 7.5 MGD.
Laboratory Yes No NA NE
Page# 3
Permit: NCO085359 Owner - Facility: Twelve Mile Creek WWTP
Inspection Date: 05/10/2018 Inspection Type: Compliance Evaluation
Yes No NA NE
Type of bar screen
0
Laboratory
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is disposal of screening in compliance?
0
❑
❑
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
❑
0
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
❑
0
Comment: Labatory analysis is performed by Charlotte Labs (Certification #192) and field prameters
performed under Field Certification #5658.
Bar Screens
Yes No NA NE
Type of bar screen
0
❑
❑
❑
a.Manual
❑
❑
❑
0
b.Mechanical
0
❑
❑
❑
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Debris is removed for disposal at county landfill.
Pump Station - Influent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
0
❑
❑
❑
Is the wet well free of excessive grease?
❑
❑
❑
0
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
0
❑
❑
❑
Are float controls operable?
❑
❑
❑
0
Is SCADA telemetry available and operational?
0
❑
❑
❑
Is audible and visual alarm available and operational?
0
❑
❑
❑
Comment: Influent is pumped from bottom of hill to headworks of plant.
Grit Removal
Yes No NA NE
Type of grit removal
a.Manual
❑
b.Mechanical
0
Page# 4
Permit: NCO085359
Inspection Date: 05/10/2018
Grit Removal
Is the grit free of excessive organic matter?
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Owner - Facility: Twelve Mile Creek WWTP
Inspection Type: Compliance Evaluation
Comment: Grit is removed for disposal at landfill. New mechanical qrit removal is
Influent Sampling
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is sampling performed according to the permit?
Comment: At time of inspection influent sampler was recorded at 5 degrees Celsius.
Oxidation Ditches
Are the aerators operational?
Are the aerators free of excessive solids build up?
# Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Are settleometer results acceptable (> 30 minutes)?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes)
Yes No NA NE
■
❑
❑
❑
E
❑
❑
❑
■
❑
❑
❑
constructed.
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
S ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
Comment: This facility has 2 dual train oxidation ditches. Ditches #1 and #2 are being operated as
oxidation ditch. Ditches #5 was under construction to change to diffused air. Ditch #6 had
been converted to diffused air and was operational at time of inspection.
Nutrient Removal
Yes No NA NE
# Is total nitrogen removal required?
0 ❑
❑
❑
# Is total phosphorous removal required?
0 ❑
❑
❑
Type
Chemical
# Is chemical feed required to sustain process?
0 ❑
❑
❑
Is nutrient removal process operating properly?
0 ❑
❑
❑
Page# 5
Permit: NC0085359
Inspection Date: 05/10/2018
Nutrient Removal
Owner - Facility: Twelve Mile Creek WWTP
Inspection Type: Compliance Evaluation
Comment: Sodium Aluminate is added to help with phosphorous removal.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
Yes No NA NE
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
Comment: Three of the four clarifiers were in Operation. Effluent from #5 and #6 clarifiers was clear with
few solids going over weirs. Effluent from #1 clarifier was clear with no notable suspended
solids.
Pumps -RAS -WAS
Yes No NA NE
Are pumps in place?
0 ❑
❑
❑
Are pumps operational?
0 ❑
❑
❑
Are there adequate spare parts and supplies on site?
0 ❑
❑
❑
Comment: It was noted that waste sludge is sent to belt thickner and then to aerobic digester.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Comment: Belt thickner was in operation at time of inspection.
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
❑
❑
❑
Page# 6
Permit: NCO085359
Inspection Date: 05/10/2018
Owner - Facility: Twelve Mile Creek WWTP
Inspection Type: Compliance Evaluation
Type of operation:
Cross flow
❑
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
0
❑
❑
❑
Is the site free of excessive foaming in the tank?
0
❑
❑
❑
# Is the odor acceptable?
S
❑
❑
❑
# Is tankage available for properly waste sludge?
0
❑
❑
❑
Comment: Sludge was being removed by truck for disposal at time of inspection. The 2017 annual
report for land apppication was reviewed with permitted application fields in South Carolina
#ND0089044. Slludge is removed and land applied by Bio-Nomic Services.
Filtration (High Rate Tertiary)
Yes No NA NE
Type of operation:
Cross flow
❑
❑
Is the filter media present?
❑
❑
❑
Is the filter surface free of clogging?
❑
❑
❑
Is the filter free of growth?
❑
❑
❑
Is the air scour operational?
❑ ❑
❑
❑
Is the scouring acceptable?
❑
❑
❑
Is the clear well free of excessive solids and filter media?
❑ ❑
0
❑
Comment: Facility has changed over from sand filters to fabric covered drum filters. At time of
inspection effluent was clear with no visible suspended solids.
Disinfection - UV
Yes No NA NE
Are extra UV bulbs available on site?
❑
❑
❑
0
Are UV bulbs clean?
0
❑
❑
❑
Is UV intensity adequate?
❑
❑
❑
0
Is transmittance at or above designed level?
❑
❑
❑
0
Is there a backup system on site?
❑
❑
❑
❑
Is effluent clear and free of solids?
0
❑
❑
❑
Comment: UV system is to be replaced a part of plant upgrade.
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
❑
0
Page# 7
Permit: NCO085359 Owner - Facility: Twelve Mile Creek WWTP
Inspection Date: 05/10/2018 Inspection Type: Compliance Evaluation
Flow Measurement - Effluent Yes No NA NE
Comment: Flow meter and flow meter channel is to be replaced as part of plant upgrade.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: Plant appeared to be well operated and maintained. It was noted at time of inspection
construction was on-going. Effluent was clear with no visible suspended solids. No foam or
floating solids were noted down stream of discharge pipe.
Page# 8