Loading...
HomeMy WebLinkAboutNCG110133_Renewal Application Information_20180531Winston-Salem • Forsyth County 4 City/County Utilities Water - Sewer - Solid Waste Disposal Muddy Creek Wastewater Treatment Plant City of Winston-Salem 4561 Cooper Road Winston-Salem, NC 27127 CityLink 311 (336.727.8000) Fax 336.650.7667 witw..CJ13'O m.org Call 311 or 336-727-8000 citylink@cityofws.org April 26, 2018 SW Individual Permit Coverage Renewal Stormwater Permitting Program 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Here is a summary for the following questions on the Supplemental Information Required for Renewal of Individual NPDES Stormwater Permit document. • Question #3 o Outfalls are monitored (visual) once per quarter, 2 times during a rain events, 2 times during dry weather. Please look at Table 2 — Industrial Outfalls for Outfall # 010 - #019 • Question #4 o Outfalls are monitored for erosion and any debris buildup, spill kits are located throughout plant for spill control. • Question #5 Plant is currently under 3 major construction projects which are o Project 1 - New Headworks/Transfer Station with two 2.0 MG equalization day tanks and two 2.3 MG storm equalization basin o Project 2 - Combine Heating and Power Jenbacher Generator with a new methane gas treatment system o Project 3 — Digester Rehab, Blower & Aeration Basin Improvements, and Thickener Clarifier & Building Rehab Please call me at (336) 784-4701 if you have any questions concerning this renewal. Sincerely: 0��r Ozie Keith Jones Senior Utility Plant Supervisor. RECEIVED MAY 0 8 2018 DENR-LAND QUALITY STORMOIATER PERMITTIV, City Council: Mayor Allen Joines; Vivian H. Burke, Mayor Pro Tempore, Northeast Ward; Denise D. Adams, North Ward; Dan Besse, Southwest Ward; Robert C. Clark, West Ward; John C. Larson, South Ward; Jeff Maclntosh, Northwest Ward; Derwin L. Montgomery, East Ward; James Taylor, Jr., Southeast Ward; City Manager Lee D. Garrity County Commissioners: David R. Plyler, Chairman; Don Martin, Vice Chair, Fleming EI -Amin; Ted Kaplan; Richard V. Linville; Gloria D. Whisenhunt; Everette Witherspoon; County Manager: Dudley Watts, Jr. City/County Utility Commission: Randall S. Tuttle ,Chairman; Wesley Curtis, Jr., Vice -Chair; Harold E. Day; Tom Griffin; Yvonne H. Hines; Duane Long; Paul S. McGill; David Neill; Chris Parker; Jim Ruffin; Donald R. Stewart SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT Two copies of each of the following shall accompany this submittal in order for the application to be considered complete: (Do not submit the site Stormwater Pollution Prevention Plan) Initials 1. A current Site Map from the Stormwater Pollution Prevention Plan. The location of industrial activities (including storage of materials, disposal areas, process areas and loading and unloading areas), drainage structures, drainage areas for each outfall, building locations and impervious surfaces should be clearly noted. N/A 2. A summary of Analytical Monitoring results during the term of the existing permit (if your permit required analytical sampling). Do not submit individual lab reports. The summary can consist of a table including such items as outfall number, parameters sampled, lab results, date sampled, and storm event data. See Attachment 3. A summary of the Visual Monitoring results. Do not submit individual monitoring reports. The summary can consist of a table including such items as outfall number, parameters surveyed, observations, and date monitoring conducted. See Attachment 4. A summary of the Best Management Practices utilized at the permitted facility. Summary should consist of a short narrative description of each BMP's in place at the facility. If the implementation of any BMP's is planned, please include information on these BMP's. See Attachment 5. A short narrative describing any significant changes in industrial activities at the permitted facility. Significant changes could include the addition or deletion of work processes, changes in material handling practices, changes in material storage practices, and/or changes in the raw materials used by the facility. 6. Certification of the development and implementation of a Stormwater Pollution Prevention Plan for the permitted facility (Sign and return attached form). If the final year analytical monitoring of the existing permit term has not been completed prior to filing the renewal submittal, then the last years monitoring results should be submitted within 30 days of receipt of the laboratory reports. (i.e. do not withhold renewal submittal waiting on lab results) Permit Coverage W16-110133 ANNPDRenewal Application Form ES Permit Number NR National Pollutant Discharge Elimination System NCS110133 Stormwater Individual Permit F Please provide your permit number in box in the upper right hand corner, complete the information in the space provided below and return the completed renewal form along with the required supplemental information to the address indicated. Owner I nformation " Address to which permit correspondence will be malted Owner / Organization Name: City of Winston-Salem Muddy Creek WWTP Owner Contact: J Frank Crump Mailing Address: 2799 Griffith Road Winston-Salem NC 27103 � Phone Number: (336) 397-7625^ Fax Number: (336) 659-4320 E-mail address: FrankCa,c*tofws org Facilitv I nformation Facility Name: Muddy Creek Wastewater Treatment Plant Facility Physical Address: 4561 Cooper Road NC 27127 1. Facility Contact: Winston-Salem. Ozie Keith Jones Mailing Address: 4561 Cooper Road Winston-Salem NC 27127 Phone Number: (336) 397-7679 Fax Number: (336) 397-7667 E-mail address: KeithJ aacityofws org Permit Information Permit Contact: J. Frank Crump Mailing Address: 2799 Griffith Road Winston-Salem NC 27103 Phone Number: (336) 397-7625 Fax Number: (336)659-4320 E-mail address Discharge Information Receiving Stream: Muddy Creek Stream Class: 303d Stream Basin: Yadkin River Basin Sib -Basin: Number of Outfalls: 9 Facility/ Activity Changes Please describe below any changes to your facility or activities since issuance of your permit. Attached a separate sheet if necessary. Currently under construction for the following - new Headworks/Transfer Station two 1.0 MG equalization tanks two 3.9 MG storm basin new Combined Heating Power Jenbacher Generator, methane gas treatment system, Digester Rehab Project Blower & Aeration Project Thickener Clarifier/Building Rehab CERTI FI CATI ON I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, co pie a and accurate. Signature Date 4/26/2018 Ozie Keith Jones Senior Utility Plant Supervisor / ORO Print or type name of person signing above Title SW Individual Permit Coverage Renewal Please return this completed application form Stormwater Permitting Program and requested supplemental information to: 1612 Mail Service Center Raleigh, North Carolina 27699-1612 STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION North Carolina Division of Energy, Mineral, and Land Resources - Stormwater Permitting Facility Name: Muddy Creek Wastewater Treatment Plant Permit Number: NCG110133 Location Address: 4561 Cooper Road Winston-Salem, NC 27127 County: Forsyth County & Davidson County "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate and complete." And "I certify that the SPPP has been developed, signed and retained at the named facility location, and the SPPP has been fully implemented at this facility location in accordance with the terms and conditions of the stormwater discharge permit." And "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations." Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND STORMWATER POLLUTION PREVENTION PLAN WITH THIS CERTIFICATION. Signature _ C),- �� 1--� Ozie Keith Jones Print or type name of person signing above Date 4/26/2018 Senior Utility Plant Supervisor / ORC Title RECEIVED MAY 0 g 2019 DENR-LAND QUALITY STORMWATER PERMIT -1 ON SPPP Certification 10/13 CERTIFICATION OF NON-STORMWATER DISCHARGES I certify, under penalty of law, that the stormwater outfalls covered by this Permit have been tested or evaluated for the presence of non-stormwater discharges under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of those persons, to the best of my knowledge and belief, no non -permitted discharges of non-stormwater enter the stormwater outfalls covered by this Permit because of activities occurring at this facility [as specified in Part II, Section A, Paragraph I (e) of the Permit]. Print Name and Official Title: Ozie Keith Jones Senior Utility Plant Operator Sinature: Date Signed: 2/19/2018 Representing: Muddy Creek WWTP 4561 Cooper Road Winston-Salem, North Carolina 27127 Methods of Evaluation Used: H Review of building and site plans. • Visual inspection of stone drainage system components (e.g., catch basins, manholes). • Observation of outfalls on a dry day that was preceded by at least 72 hours of dry weather. H Interview with facility personnel. ❑ Flow tests using water, tracers, dyes, or smoke. The Permittee is aware of the upset or bypass notification procedures as specified in the facility's NPDES General Permit and will act accordingly (See P I Sections C and E of the Permit). `DEEIVED MAY O 8 2018 DENR-LAND QUALITY STORMWATER PFRMITT:rgr. Muddy Creek WWTP Stormwater Pollution Prevention Plan NPDES General Permit No. NCG110133 Page 14 TrailY Park` i. `' Ai: 303d Streiin M ��, � � j"�� � ate_ '�~t %•.,, r � r' ''-'"�� � •��`� ��l� `f,�\ C„1 J ./"' tit.- r. . ` ii � • J / � i`�✓�i� - -.� �' - '� ..._� Afuddv Creek '4I�4'TP. 1403 til i •r> i • �. .� - i __ Wk WELCOME, NC (1991) QUADRANGLE RECEIVED 7.5 MINUTE SERIES, 1:24000 MAY 0 g 2016 MAP 1 - SITE LOCATION Al" DENR-LAND QUALITY STORMWATER PERMITTING Muddy Creek WWTP Stormwater Pollution Prevention Plan NPDES General Permit No. NCGI10133 Page 3 W T-, -T- Ic IL M Legend 101, Outfalls (with SDO Number) 4 Streams N Forsyth County Boundary Figure I - Aerial View of Plant Muddy Creek WVVTP Parcels Muddy Creek WWTP A Industrial Activity Area (Refer to Table 3) Stormwater Created by: KMPollution Prevention Plan L Checked by: CDJ 3 EWELL Note 2005 Aerial obtained fn- Forsyth County website. 4, Scale 1 inch = 80 lee, Date July 2008 ED 18 Legend SLUDGE LAGOONS0 Catch Basins SLUDGE A outfous iIE LAGOONS Aboveground Storage Tanks (ASTs) ............ % Dry Ditch % %. Overland Surface Flow % ...... Storm Drain . % Tree Ones Edge of Pavement Edge Unpaved Surface .Drainage Area WWTP Features Buildings SULIDdIr-' Concrete Pad BLENDING % TANKSC3 Forsyth County Boundary AIndustrial Activity Area (Refer to Table 3 Sour— Forsyth County PI—t— HDR and OHewn & Sawyer Sde Pins BLENDED 6LUDGE" PUMPING STATION Map 2 -Area I Northern Section of Site STORAGE Muddy Creek WWTP Stormwater Pollution Prevention Plan Created by KML tI Checked by: C -i 'JEWELL ** ..4p Scale: 1 inch - 80 feet % I Date: July 008 DRY DITCH < DRY DITCH CB#10.1 C8#10.3 CB#10.6 CB#10.7 C8#12.4 e1q CB#1 0.2 10.4 CB#CB#10.5 CB#10.8 12.3 VZ) �0_ #12.1 ---A )MINISTRATI BUILDING DIGESTER CB#�2 DIGESTER SDO-012 NO- 1 NO. 4 DA = 0.49 ac Imp = 100% H 70 AST -7 FUER Q 'CAUSTIC GEPRESS ' AN �, \ Bt ...... ST 10 FEEDISTORA DIGESTER CONTROL UILDING AFACiunES ------ — :11 ................................ ........... ..... . it' ST 12 :CB#19.. ........... .... .............. AST -1 SDO-013 CB#19.1 DIGESTER DIGESTER CB#1 NO. 2 NO. 3 DA = 1.82 ac •Imp z: 98% CB#19.2 80 Feet CB#19.5 C 13 80 40 0 SOUTH FORK AST -6 CB#13.5: B#13.6 4? INTERCEPTOR FLU • 3 CB#13.3: j'1.. ....... ........... MAST -2 ................. : . .......... ........... MATCH LINE - See Map 3 - 2AT H LI ... ................ ---------------------------- ---- ........................... *Asu ........ . ...... 65% C�hSOUTH FORK 13.6 INTERCEPTOR FLU AST 6E CB#13.5: G7 J ........................ —...r,i ........ WAST-2 ...... ....... I ................. .3 MATCH LINE _ _ _4 ....................... ........ .......... BLOWER Shad BUILDING PRIMARY CLARIFIERS K AERATION BASINS AST-11 TRETMEN P"Euml"ARYN B#14 SDO-014 BUILDINGAT DA =1.80 ac rt .Imp 79% .B#14.3...... ..... .............................. CBN18.1 ................................ 1. CB#14, . q K .... B#18.2 CB#14.2 SDO-018 OCB#14.4 DA = 0.95 ac B#1 8.3 .... .. Imp 60% B .5: 41 AST M SECONDARY CLARIFIER 1 CLARIFIER 4 SECONDARY D THICKENED WA OUSE GpJN SLU Pump, THICKENER t B#11 5.5 STATION % % CE415.6 FSR oN .... ........J�pS.... Legend • ......... ... -RETURN E Catch Basins SLUDGE PUMP CB#15.4 A Outfalls CHEMICAL,' @ STATION Aboveground Storage Tanks (ASTs) STORAGE AST-9 Dry Ditch L'TIF, 1(1........... CB#1 5.1; Overland Surface Flow S• •...... Storm Drain A Tres Ones S 4 SECONDARY CLIATION SECONDARY CLARIFIER 3 Edge of Pavement B#1 .3 BUILD GNPW PUMP STATION Edge Unpaved Surface B#17.4 •Drainage Area % ........... VWVTP Features Buildings C8#17.2. 8#16. B#16.3 •CB#15.2y'/ B#17.1 — Concrete Pad #16.1 CB#15.' Forsyth County Boundary nn SDO-016 Alndustrial Activity Area (Refer to Table 3 Sources: Forsyth County PlanimaUx3, HDR and SDO-017 Fl. C DA =1.39 ac SDO-01 5 N Hf1w AS W Sft PWS DA = 0.95 ac Irnp= 44% —' K,�� DA = 0.97 ac Imp = 64% Imp = 66% Map 3 -Area 2 Southern Section of Site Muddy Creek WWTP 80 40 0 80 Feet Stormwater Pollutign Prevention Plan Created by: KML Checked by, CDJ UEWELL Scale, 1 inch 90feet Date: July 2009 CoN5U�,�T%_ There is no runoff from other industrial properties onto this Permittee's facility, nor does off-site industrial runoff enter any of this Permittee's stormwater drainage outfalls. Offsite stormwater drainage systems are not mapped as part ofthis SWPPP. The industrial drainage outfalls are identified in Table 2. The approximate location of these outfalls (defined here as point source discharges ofstormwater to "waters of the State") are shown in the table. TABLE 2 - INDUSTRIAL OUTFALLS SDO TYPE AREA LATITUDE LONGWODE MONErOR)NG 010 Pipe N 350'59.807' W 800 20.085' visual 011 Pipe Up&w&ent of SDO-010 012 Pipe N35"59.810' W 80" 19.877' visual 013 Pipe N 350 59.760' W 800 19.877' visual 014 Pipe N 350 59.737' W 800 19.877' visual 015 Pipe N 350 59.664' W 800 19.879' VIsoal 016 Pipe N 350 59.655' W 80° 19.951' v>saal 017 Pipe N 350 59.658' W 80° 20.024' visual 018 pipe N 350 59.728' W 800 20.042' visual 019 Pipe N 350 59.772' W 800 20.049' visual Sto=water discharge monitoring as shown in Table 2 will be performed at the designated outfall points as located on the facility area maps. Visual monitoring will be conducted at all outfalls as described in Appendix B. Other discretionary points within the facility that may be useful to isolate potential pollutant sources can be identified and observed by the Permittee. Muddy Creek WKF StormwaterPollt on Prevention Plan NPDES General Permit No. NCG110133 Page 6 TABLE 3 - MUSTRIAL ACTIVITY AREAS AREA ACTIVITIES POLLUTANTS IMPLEMENTED BMPs A Bulk Chemical Storage Sodium Hypochlorite ASTs are within secondary Bulk Chemical Deliveries containment. Chemicals are delivered via DOT -approved tankers. Trained personnel perform & observe deliveries. B Liquid Caustic Storage 25% Sodium ASTs are within secondary Liquid Caustic Deliveries Hydroxide containment. Spills would be diluted with water, then discharged into the WWTP. Chemicals are delivered via DOT -approved tankers. Trained personnel perform & observe deliveries. C Sludge Thickening Liquid Caustic, ASTs are within secondary Chemical Deliveries Polymer containment. Chemicals are delivered via DOT -approved tankers. Trained personnel perform & observe deliveries. D Fuel Oil Storage Diesel Fuel AST is within secondary Fuel Oil Deliveries containment. Re -fueling Fuel is delivered via DOT- OTapproved approvedtankers. Trained personnel perform & observe deliveries. E Fuel Oil Storage #2 Fuel Oil AST has integral secondary Fuel Oil Deliveries containment. Fuel is delivered via DOT- OTapproved approvedtankers. Trained personnel perform & observe deliveries. F Sludge Handling Sludge Sludge is blended in concrete pits. Trained personnel observe pumping into tanker trucks for off-site drying. G Ammonium Nitrate Storage 30% Liquid Nitrogen AST is within secondary Ammonium Nitrate Deliveries containment. Trained personnel perform & observe deliveries. Spills will be discharged thru the WWiTP. H Corrosive Storage 47% Ferric Chloride or AST is within secondary Corrosive Deliveries 28% Ferrous Chloride containment. (labeled FST -1) Trained personnel perform & observe deliveries. Muddy Creek WWTP StornmWer Pollution Prevention Plan NPDES General Permit No. NCG110133 Page 9 AREA ACTIVITIES POLLUTANTS IMPLEMENTED BMPs Chemical Storage Ferric Chloride Totes & bags are stored inside Chemical Deliveries Polymers the building. Dispersants Trained personnel perform & observe deliveries. J South Fork Odor Scrubber Chem Carton Pellets AST is within secondary Storage containment. Chemical Deliveries Condensate drains to headworks. Trained personnel perform & observe deliveries. K Misc. Chemical Storage Hydrogen Peroxide Drums are stored inside Misc. Chemical Deliveries various Motor Oils warehouse. Ethylene Glycol Trained personnel perform & observe deliveries. L Vehicle/ Equipment Wash Area Detergents Drain is connected to Dirty wash water headworks. M Abandoned Equipment Storage Aluminum Chloride Exposed equipment will be Chemical Storage solution removed or stored under cover. Polymers Totes and bags are stored Dispersants inside warehouse. N Bar Screen Debris Accumulation Trash Roll -off Container is under shed roof. Gravity sump is connected to headworks. Debris is landfilled 3x perweek. O Lime Silo and Feeding System Hyadrated Lime This system is in place to help maintain pH and alkalinity for process control P Q Anaerobic Digester Pump Oil Bldg drains are pumped to Maintenance Wastewater headworks. R Truck Shed: Equipment Storage Oil Equipment is parked under a & Maintenance Gasoline shed roof. Muddy Creek WWTP StormwaterPoUution Prevention Plan NPDES General Permit No. NCGI10133 Page 10