Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0024911_Industrial User_20180523
Q\\,CPN SEWE94Q ° ��� Metropolitan Sewerage District z OF BUNCOMBE COUNTY, NORTH CAROLINA '1jeF GP C'°LINTY NOPZN May 23, 2018 Deborah Gore PERCS Unit Supervisor 1617 Mail Services Center RECEIVED/p Raleigh, NC 27699-1617 ENR/D1NR MAY 25 2018 Re: NOV-2018-PC-0161 Water Resources Permitting Section Dear Ms. Gore: Although I have yet to receive a hardcopy of your letter of Notice of Violation issued to MSD Pretreatment Program dated May 16, 2018, I am responding to the one received via email on Monday, May 215T. Needless to say, MSD's management was stunned to learn of the omission of required documents and is pursuing immediate action to correct this. Our intentions are to send all documents by the June 15th deadline. I am enclosing with this letter thirteen signed copies of SIU permits, permit rationale and applications. In all, of the 20 permitted SIUs only six permits remain outstanding. We take this matter very seriously and will conduct a thorough investigation on how this normal administrative process could have been overlooked. And rest assured that follow up measures will be taken to make sure this will not happen again. In the meantime, please direct all future correspondence to my direct attention. As we continue to work to get the requested information together should you have any questions, you may contact me on my direct line (828) 225-8225. Resp tfu,y, Monty °tyne Field Operations Manager, MSD Metropolitan Sewerage District, BC 2028 Riverside Dr. Asheville, NC 28804 CC: Thomas E. Hartye, P. E., MSD Peter C. Weed, MSD Roger Edwards, MSD Vivien Zhong, PERCS Unit Linda Wiggs,ARO -Protecting Our Natural Resources 2028 RIVERSIDE DRIVE, ASHEVILLE,NORTH CAROLINA 28804 TELEPHONE:(828)254-9646 FAX:(828)254-3299 WEBSITE:www.msdbc.org 1 THE METROPOLITAN SEWERAGE DISTRICT OF - BUNCOMBE COUNTY,NORTH CAROLINA ok QoNS\ save s Q 9 : : 4��' - - COUNTY.Nppt' PERMIT TO DISCHARGE INDUSTRIAL WASTE FOR SIGNIFICANT INDUSTRIAL USER Permit No: S-036-17 40 CFR Category: N/A In accordance with all terms and conditions of the Sewer.Use Ordinance (SUO) of the District Board of the Metropolitan Sewerage District of Buncombe County, North Carolina (MSD), NPDES Permit No: NC0024911 for .the operation of the Metropolitan Wastewater • Treatment Plant by MSD, North Carolina General Statute 143-215.1, and other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission and the District Board of the Metropolitan Sewerage District of Buncombe County, North Carolina: PERMISSION IS HEREBY GRANTED TO: Milkco,Inc. 220 Deaverview Road Asheville,North Carolina 28806 FOR THE discharge of wastewater from sanitary fadlities and process facilities classified by Standard Industrial Classification (SIC) Code Nos. 2026, 2037 and 3085 into the District Sewerage System of the.Metropolitan Sewerage System at 220 Deaverview Road,Asheville,North Carolina'28806. The discharge shall.be in accordance with effluent limitations, monitoring requirements and other conditions set forth in this.Permit to;Discharge Industrial Waste (the"Permit"). Effective this 1st day of January,2017 This Permit expires the 31st day of December,2021: METROPOLITAN SEWERAGE DISTRICT OF BUNCOMBE COUNTY,NORTH CAROLINA p L/ I' Thomas E' „ e,P.E. Date arty Gener anager 1 Permit No. S-036-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS A. Description of Discharge(s) Pipe No. Description 01 Process Wastewater, Boiler and Cooling Tower Blow Down 02 Domestic Wastewater 03 Truck Trailer Rinse Water Monitoring Point Description. MP01 Process Wastewater Flume Site Layout _.., _._ � DW�R EAVERVIED..• .,,Y. , _ '' , ,..-„,,-,,........._ ... _....1111 ' r...____.: ..., ,,,,,, t lAnrir k -. . ii;ii.i 1 —. 1 - ' c ..1 , , F t i- ''. 4 ' Allt i i , V' 11. 18° . 1 isErft 4 a# e . t.., ., F tog f -- 1.717 - ,....•,P7.. .., „ , „ i :tit IR 4. .1. '• . 0� Nr11.F ,; I 10 fk...26 4ill I Pipe 01 i� �'-""�'ra rP `. . ,.r. P 26947 ' • 269488 4�4 r t M "AN no I i , -, 26949 +'' ) �, 7097 :12 , 1 Ilfr.,, " L' + _ ; i _x , . _ Pipe 024.,.. - ,V11111111h imillhos- . .� \ I t s" ! r 4 4 Pipe 03 9 \ -.= i ► t ‘*'''.. . 29 26945 *Discharge at Pipes 02'and 03 may be monitored periodically and unannounced by MSD to assess compliance. Prior to any discharge of,process wastewaters into these pipes, a Permit Application must be submitted to the MSD and a new Permit issued. Permit No. S-036-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS Monitoring Point 01 • . I ti ,i+ �y j Entrance to MP 01 4 a a ''�. ; : gj mow. t°;'.- _i' 41' I'c 4'1 � 'V, 1. ' . - is ., li dit Flow 1 _ Meter .fit V,,,, MP 01 is in flume IP" r• 1 - s• behind wall , ' rU 1 kr • ,4 j . 4 , Permit No. S-036-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS B. Effluent Limitations Effective immediately and lasting until the expiration of the Permit, the Industrial User is authorized to discharge process waste to Pipe No. 01. The discharge shall be limited and monitored at MP 01 as specified below:. EFFLUENT LIMITATIONS Limited Daily Sample Monitoring Frequency Parameter Maximum Units Type MSD Industry Flow 0.200 MGD Continuous Once/Year Daily pH 6.0 to 10.5 Std:Units Grab Once/Year Daily BOD 4500 mg/1 Composite Once/Year Twice/Month TSS 2000 mg/1 Composite Once/Year. Twice/Month C. Effluent Monitoring Conditions • 1. . The scheduled monitoring frequencies are minimum requirements and may be adjusted by MSD. 2. Flow is in million gallons per day (MGD): The permitted flow is monitored at the flume. The flow meter is to be calibrated on an annual bases. A copy of the calibration report is to be submitted to MSD with the Subsequent Monthly Monitoring Report. 3. The pH shall be not less than 6.0 or greater than 10:5 standard units.. Deviations from these limits shall be handled in accordance with.MSD'Pretreatment Program Guidance Policy. 4. Where continuous pH recording equipment is utili7ed,the lowest and highest reading shall betaken from,a 24 hour chart. The reading closest to the pH range limits,is the reading to report on the Monthly Monitoring Report. 5. Discharge of Parameters not specifically limited in this Part•is:limited to Domestic Sewage Levels as established by the District's Sewer Use Ordinance, 6. No dilution, such as unregulated,process wastewater or domestic shall be introduced into Pipe 01 as identified in the Site Layout on Page 3 of the Permit. 7. Continuous and composite samples shall be at least twelve (12) portions collected during a twenty-four (24) hour period or the total duration of waste discharge if less than twenty-four(24)hours. Alternate sampling requirements may be established in a User's.Permit to Discharge Industrial Waste or by the General Manager. 5 Permit No. S-036-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS C. Effluent Monitoring Conditions (continued) 8. A "grab" sample, for monitoring requirements, is defined as a single "dip and take" sample collected at a representative point in the discharge stream. 9. An instantaneous measurement, for monitoring requirements, is defined as a single reading,observation,or me surement. D. Monitoring and Reporting 1. Representative Sampling a. Samples andmeasurements taken as required herein shall be representative of the volume and nature of e monitored discharge. All samples shall be taken from Pipe numbers specfie in the Permit and, unless otherwise, specified, before the effluent joins or is dilut d by any other wastestrearn,body of water, or substance. Pipe numbers shall not e changed without notification to and approval by MSD. b. Samples must be collected and composite (a minimum of twelve portions) over an entire operating day. ere weekly samples are required,a progressive schedule will be used,Monday one week,Tuesday the next,etc. c: Test procedures for the analysis of pollutants shall beperformed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto unless specified otherwise in the monitoring conditions of the Permit. d. All records of analysis.= d measurement performed by the Industrial User must be retained by the Ind •trial Userfor three(3)years. 2. Reporting a: : Monitoring results ob . edby.the Industrial Usershall be reported on the Self- Monitoring Monthly eport Forms on MSD's website with signed hardcopies of the Forms and suppo ting lab analyses postmarked no later than the twentieth day of the month follo wing the month in which the samples were taken. If no discharge occurs d g the reporting period, "no discharge" shall be indicated on the Forms. -Copie. of these and contract laboratory reports 'shall be faxed, emailed or submitted io the MSD at the following address: Attentio : Industrial Pretreatment Coordinator Metropo tan Sewerage District 2028 Riverside Drive Asheville,North Carolina 28804 - 6. Permit No. 5-036-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS D. Monitoring and Reporting(continued) b. In the event of an accidental discharge,slug loading or self-monitoring indicating non-compliance with the SUO or the Permit,the Industrial User shall notify MSD within 24 hours of becoming aware ofthe violation by using the Report Forms on MSD's Self-Monitoring Monthly Report Form website. c. If the accidental discharge, slug loading, orself-monitoring is suspected of severely impacting the MSD-sewer system, endangering public safety or the safety of MSD employees, the Industrial User shall immediately notify MSD by telephone of the non-compliant event. The telephone numbers to contact are: Time and Days Contact Telephone Number 830 am to 430 pm,Monday-Friday Industrial Pretreatment Coordinator (828)254-9646 after 430 pm,weekends,and holidays Operator on duty (828)225-8228 d: Within five (5) days of the accidental discharge, slug loading or other non- compliant oncompliant discharge, a written report by the authorized representative of the Industrial User shall be submitted to the General-Manager of the MSD. The report must include as a minimum: (i) The date, time and duration of the accidental discharge, slug loading or discharge not in compliance with conditions and requirements of the SUO or the.Permit; (ii) The quantity and waste characteristics of the.discharge; (iii) The corrective action taken to prevent future accidental discharges, slug loadings or discharges not incompliance with the SUO or the Permit. e. If self-monitoring by an Industrial User indicates a violation,the Industrial User shall repeat the self-monitoring and analysis and,submit the results of the repeat analysis to MSD within thirty (30) days after becoming aware of the violation. The requirements of this paragraph are in-addition to the requirements set forth in subparagraphs b:,c.,and d.of this Part. • 1- Permit No. S-036-17 PART III GENERAL CONDITIONS AND REQUIREMENTS A. Duty to Comply The Industrial User must comply with all conditions of the Permit. Any non-compliance with the Permit constitutes a violation of the SUO and may be grounds for possible, enforcement action. The .MSD may levy fines of up to twenty-five thousand dollars ($25,000.00) per day per violatiop. The Industrial User may be subject to criminal penalties levied by the State of North Carolina or the United States of America. B. Duty to.Mitigate-Prevention of Adverse Impact The Industrial User shall take all reasonable steps to minimize or prevent any discharge in violation of the Permit which has a reasonable likelihood of adversely affecting human health,the MSD Treatment Plant,the French Broad River,or the environment. C. General Prohibitive Standards In addition to the requirements of the Permit,the Industrial User shall comply with the general prohibitive discharge standards in 40 CFR 403.5(a) and (b) of the Federal pretreatment regulations. D. Facilities Operation The Industrial User shall at all times maintain ingood working order and operate as efficiently as possible, all control facilities or systems installed or used by the Industrial User to achieve compliance withlthe terms and conditions of the Permit and the SUO. E. Bypass 1. Bypass of treatment facilities is prohibited. MSD may take enforcement action against the Industrial User for bypass unless MSD approves when such bypass is in compliance with.40 CFR 403.17. Such conditions are: a. Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; b. There were no feasible alternatives to the bypass. This condition is not satisfied if adequate back-up equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventative maintenance;and c. The Industrial User knows in advance of the need for the bypass, submits prior notice of the bypass to MSD.. • 8 Permit No. S-036-17 PART III. • GENERAL CONDITIONS AND REQUIREMENTS 2. If the Industrial user does not know of the bypass in advance, it must submit verbal notice to MSD as soon as the Industrial User becomes aware of the bypass. The verbal notice shall be followed with a written submission. The written submission shall ' describe the bypass and its.cause; state how long the bypass occurred including exact dates and times, and if the bypass has not been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate and prevent reoccurrence of the bypass. F. ' Flow Measurement. 1: Flow measuring and recording facilities shall be maintained to provide an accurate measurement of the volume discharged. If it is the determination of the MSD that when,in the opinion of the MSD or Industrial User,the flow measuring and recording facilities are not sufficiently measuring the flow, the MSD may require recalibration or change-out at theexpense of Industrial User. 2. Any malfunction of flow monitoring and recordingequipment shall be reported by the Industrial.User immediately to MSD by phone followed by a written report submitted to the General-Manager of MSD within five (5) days, of the malfunction. Any• malfunction must be corrected within seven (7) days. Certification of accuracy must be provided to MSD within fifteen(15) days of the date of repair. G. Reports of Changed Conditions 1. The Industrial User shall give notice to the General Manager ofany planned significant changes to the operations or system which might alter the nature,quality, or volume of its wastewater at least 180 days before the change. The Industrial User shall not begin the changes until receiving written approval from MSD. Significant changes may include but are not limited to the following: • a. increases or decreases to production; b: increases in discharge of previously reported pollutants; c. discharge of pollutants notpreviously reported; d. new or changed product lines; e. new or changed manufacturing processes. 2. Discharge of wastewater with changes as indicated above shall not begin until a Permit to Discharge Industrial Waste has been issued by MSD for the proposed discharge or until MSD amends an existing Permit. Permit No. S-036-17 PART III GENERAL CONDITIONS AND REQUIREMENTS H. Removed Substances Solids, sludge, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in a manner such as to prevent any pollutants from such materials from entering the sewer system. The Industrial User is responsible for assuring its compliance with 'any requirements regarding the generation, treatment, storage, or disposal of "Hazardous Waste" as defined under the Federal Resource Conservation and Recovery Act. - L Upset Conditions An "Upset" of Pretreatment Facilities means an exceptional incident in which there is an unintentional and temporary noncompliance with the effluent limitations of the Permit because of factors beyond the reasonable control of the Industrial User. An Upset does not include noncompliance to the extent caused by operational error, improperly,designed or inadequate treatment facilities, lack of preventative maintenance, or careless or improper operations. An.Upset may constitute an affirmative defense for action brought for the noncompliance. The Industrial User has the burden of proof to provide evidence and demonstrate that none of the factors listed in the preceding paragraph were responsible for the noncompliance. J. Toxic Pollutants If a toxic effluent standard or prohibition(including any schedule of compliance specified in such effluent standard or prohibition) is established under Section 307(a) of the Federal Clean Water Act or North Carolina General Statutes 143-2151 for a Toxic.Pollutant which is present in the discharge and such standard or prohibition is more stringent than any limitation for such pollutant ' the Permit, the Permit may be revised or modifiedin accordance with the toxic effluerit standard or prohibition. K. Accidental Dischar:es and Slu•Loads The _Industrial User shall pro 'de protection from accidental and slug discharges of prohibited materials or other su.stances regulated by the Permit 1. Such protection shall indu e, but is not limited to the construction of containment dikes,the rerouting of all flo r drains in the manufacturing area to a'holdirig area,and the plugging of,floor dr . Modifications to o the measures shall be approved by MSD prior to installation or ' plementation. 2. A written contingency pl shall be submitted to MSD, which outlines the procedures to be taken by the Industrial.User in the event that an accidental spill or leak of a prohibited substance occurs. The plan shall also include notification procedures outlined in Part II,Section D.3.b.,c.,and d.of this Permit. 10 Permit No. S-036-17 PART III GENERAL CONDITIONS AND REQUIREMENTS a. The Industrial User shall review and revise, as needed,the written contingency plan every three(3)years. Description of Plan Submittal Date Submit revised version of"Spill.Prevention December,2016 Control and Countermeasures" 3. A Notice shall be permanently posted at a prominent place in the facility for which the Permit has,been issued advising employees whom to call in the event of an Accidental Discharge. Users shall insure that all employees who observe or who may cause or suffer such an Accidental Discharge to occur are advised of the emergency notification procedure. The notification procedure'outlined,in Part II,Section D.3.b., c., and d. of this Permit shall be followed. L. Need to Halt or Reduce not a Defense It shall riot be a defense for an Industrial User in an enforcement action that it would have been necessary to halt or reduce the permitted activity to maintain compliance withthe. conditions of the Permit. M. Dilution The Industrial User shall not increase the use of potable or process water or in any other way attempt to dilute the discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in the Permit. N. Right of-Entry • The Industrial User shall allow the staff of the Metropolitan Sewerage District, the,North Carolina Department of Environmental Quality, the Environmental Protection Agency and/or their authorized representatives,upon the presentation of credentials: 1. To enter upon the Industrial User's premises where a real or potential discharge.is . . locatedor in which records are required to be kept under the terms and conditions of the Permit;and 2. At reasonable times to have access to andcopy records required to be kept under the. terms and conditions of the Permit;to inspect any-monitoring equipment or monitoring method requiredrin the Permit;and to sample any discharge of pollutants. - O. Monitoring Access MSD,.the Approval Authority and EPA shall have the right to set up on the Industrial User's Property such devices as are necessary to conduct sampling,inspection,compliance monitoring and flow metering operations. 11 Permit No. S-036-17 PART III GENERAL CONDITIONS AND REQUIREMENTS P. Availability of Records and Reports The Industrial User shall retain records of all monitoring information, including all calibration and maintenance records as well as copies of reports and information used to complete the application for the Permit for at least three(3)years. All records pertaining to any enforcement action shall.b,' retained and preserved by the Industrial User until all enforcement activities have concluded and all periods of limitation with respect to any and all appeals have expired. Except for data determined to be confidential under the Sewer Use Ordinance, all reports prepared in accordance with terms of the Permit shallbe available for public inspection at the Metropolitan Sewerage District. Effluent data shall not be considered confidential.. Q. Duty to Provide Information The Industrial User shall furnish to the General Manger or his designees, within a reasonable time, any information MSD, or its designee,or the North Carolina Department of Environmental Quality may request to determine whether cause exists for modifying, revoking and reissuing, or terminating the Permit or to determinecompliance with the Permit. The Industrial User shall also furnish, upon request, copies of records required to be kept by the Permit. R. Penalties for Falsification of Reports The Metropolitan Sewerage District SUO provides that any person who knowingly makes any false statements or, representation in any application or report or other document submitted or required to be maintained pursuant to the SUO or the Permit,`or who knowingly renders inaccurate any monitoring device or method required under this ordinance, shall upon conviction be punished by a fine of not more than$25,000 for each violation. NCGS 143-215.6B provides that similar offenses may be punished by a fine of up to$10,000 per violation. S. Signatory Requirements All reports or information submitted pursuant to the requirements of the Permit must be signed and certified by the Authcrized Representative of the Industrial User as specified in the Application for Permit to Discharge Industrial Waste. _. If the designation of the Authorized Representative is no longer accurate,.a new authorization satisfying the requirements of this section mu t be submitted to General Manager prior to or together with any reports to be signed by the new Authorized Representative. 12 Permit No. S-036-17 PART III GENERAL CONDITIONS AND REQUIREMENTS T. Civil and Criminal Liability Nothing in the Permit shall be construed to relieve the Industrial User from civil or criminal penalties for noncompliance with provisions of the Permit. U. Federal and State Laws , Nothing in this permit shall be construed to preclude the institution of anylegal action or relieve the permittee from any responsibilities,liabilities, or penalties established pursuant to any applicable Federal and State law or regulation. V. Property Rights The Permit does not convey any property rights m either real or personal property,or any executive privileges,nor does it authorize any injury to private property or any invasion of personal rights,nor any infringement of Federal,State or local laws or.regulations. W. Severability The provisions of the Permit are severable and, if any provision of the Permit or the application of any provisionof the Permit to any circumstance is held invalid, the application of such provision to other circumstances and theremainder of the Permit shall not be affected thereby. X. Re-opener Provision The Permit shall be modified, or alternatively, revoked and reissued, to comply with any applicable effluent standard or limitation issued or approved,under Sections 302(b)(2)(C) and(D),304(b)(2)and 307(a)(2)of the Clean Water Act,if the effluent standard or limitation so issued or approved: 1. Contains different conditions or is otherwise more stringent than any effluent limitation in the Permit;or ' 2. Controls any pollutant not limited in the Permit. The Permit as modified or reissued under this paragraph shall alsocontain any other requirements of the Clean Water Act then applicable.. 13 Permit No. 5-036-17 PART III GENERAL CONDITIONS AND•REQUIREMENTS Y. Permit Modification,Revocation,Termination The Permit may be modified,revoked and reissued or terminated in accordance with the requirements of the SUO, North Carolina General Statute 143-215.1 and regulations promulgated thereunder. The Permit shall be modified, alternatively or revoked and reissued, to comply with any applicable effluent standard or limitation'for the control of any pollutant shown to contribute to the toxicity of the MSD Wastewater Treatment Plant effluent or any pollutant that is otherwise limited by the MSD Discharge Permit. The Permit as modified or reissued under this paragraph may also contain any other requirements of State or Federal pretreatment regulations then applicable. Z. Application for Permit Renewal The Industrial User is responsible for filing application for re-issuance of the Permit within one hundred and eighty(180)days of its expiration.date. AA. Transferability The Permit shall not be reassigned ortransferred or sold to a new owner, new Industrial User, different premises or a new or changed operation without the written approval of MSD. Any succeeding owner or Industrial User shall also agree in writing to comply with the terms and conditions of the Permit and shall be provided a copy of the Permit. BB. Construction No construction of pretxeatmen facilities or additions thereto shall commence until Final Plans and Specifications have een submitted to MSD and, written approval and an Authorization to Construct(A to C)have been issued. 14 Permit No.S-036-17 THE METROPOLITAN SEWERAGE DISTRICT OF ' BUNCOMBE COUNTY,NORTH CAROLINA ��o�cAN SEWfq� /�9 O • may Kms. / g `� o - COMB IV41 LLIIV�' SPP ''COUNTY,N3? • PERMIT RATIONALE FOR Permit No. S-036-17 Effective Date: January 1,2017 Expiration Date: December 31,2021 A. Basic Information 1. Name and Address of User. - Milkc°,Inc. 220 Deaverview Road • Asheville,North Carolina 28806 2. Description of User's Operation • i) SIC Code Nos.2026,2037 and 3085: Manufacturer of milk processing with secondary process lines of bottled water, fruit flavored drinks and orange juice and a secondary process of plastic injection mold. • ii) 40 CFR Category:N/A 3. Name of WWTP Receiving Wastewater Metropolitan Sewerage District of Buncombe County,NC • French Broad River Water Reclamation Facility NPDES Permit No. NC 0024911 1 Permit No.S-036-17 B. Rationale For Limitations and Effluent Limits The following pollutants were assigned numerical limits in this Industrial User Permit for Monitoring Point 01 based on the MSD Sewer Use Ordinance (SUO) or Best Professional Judgment(BPJ). Daily Pollutant? Maximum Units BOD 4500 mg/1 TSS 2000 mg/1 These limits do not result in over allocation the Maximum Allowable Industrial Loading determined with the HeadWorks Analysis among all Users. The Metropolitan Sewerage Treatment Plant is experiencing no difficulty treating the industrial waste it is receiving at this time. Permit limits are based on the current Headworks Analysis, which considers most recent available industrial monitoring and analytical characterization of the MSD Wastewater System. Limits established in Permits to Discharge Industrial Waste were utilized in the Headworks Analysis to • determine the capability of the Wastewater Treatment,Plant'to operate within design and Permit Limits, pass-through and receiving stream Water Quality Criteria, and without. chemical inhibition. 2 • SIGNIFICANT INDUSTRIAL USER APPLICATION o>�"" '" '�F FOR Q°e- % PERMIT TO DISCHARGEIVISD z AND WASTEWATER SURVEY 5° MSD USE ONLY Metropolitan Sewerage District of Buncombe County,North Carolina Industrial&Commercial Waste Division 2028 Riverside Drive ISSUED: 20 Asheville,North Carolina 28804 Telephone(828)254-9646 RECEIVED: 20 Telecopier(828)232-5546 REVIEWED: 20 RETURNED FOR COMMENT: 20 Pursuant to the Sewer Use Ordinance of the Metropolitan Sewerage District of Buncombe County,North Carolina(MSD),all persons who are users or may become users of the sewerage systems are subject to regulation. Some of the objectives of our Ordinance and this wastewater survey/and application are: To prevent the introduction of pollutants into the Sewerage System which will interfere with the operation of the Sewerage System or contaminate the resulting sludge generated; To prevent the introduction of pollutants into the Sewerage System which will pass through the system,inadequately treated, into any waters of the State or otherwise be incompatible with the Sewerage System; To promote reuse and recycling of industrial wastewater and sludges from the Sewerage System;and To provide for the regulation of direct and indirect contributors to the Sewerage System,through the issuance of permits to certain nondomestic Users and through enforcement of general requirements for the other Users;authorizes monitoring and enforcement activities,requires User reporting and provides for the setting of fees for the equitable distribution of costs. 1. COMPANY BUSINESS NAME: Milkco,Inc. Site Location: 220 Deaverview Road Phone: (828)254-9560 City: Asheville State: NC Zip: 28806 Mailing Address: P.O.Box 16160 City: Asheville State: NC Zip: 28816 2. CHIEF EXECUTIVE OFFICER Name: Keith Collins Title: President Mailing Address: P.O.Box 16160 Phone: (828)254-9560 City: Asheville State: NC Zip: 28816 3. PERSON ON SITE (Authorized to Represent this Firm in Official Dealings with the MSD) Name: Rhett Flanders Title: Operations Manager 4. TYPE OF APPLICATION&WASTEWATER SURVEY ®Renewal for existing facility ❑Revision for change in discharge or facilities modification ❑New facility (Anticipated date of discharge commencement: ) ❑Change in ownership 1 5. GENERALINITRECTIONS a. All terms used herein are as defined in the Sewer Use Ordinance of MSD. b. All persons receiving an Application form are to answer Ouestions 1 through 12.. 13.. 15, and 16. c. If water is used in such manner as to produce possible industrial or commercial wastes as indicated by positive answers to any of the Ouestions 10. Al 4.. throueh 10. M 8., you are required to furnish additional information by answering Ouestions 12.And 14. d. Where industrial or commercial wastes are discharged,a Permit to Discharge Waste will be issued to the User(or rejected)subject to the requirements of the Sewer Use Ordinance of MSD and any special requirements as contained in the Permit to Discharge Waste. e. The User may, if so desired, assert a business confidentiality claim covering all or part of the information in this Application in accordance with provisions of Section 12 of the Sewer Use Ordinance of MSD. To file such a claim,contact the General-Manager of MSD for further details. f. Submit the completed Application/Survey and attachments to: General Manager • Metropolitan Sewerage District of Buncombe County 2018 Riverside Drive Asheville,North Carolina 28804 6. GENERAL PERMIT CONDITIONS a. A Permit issued in response to this Application/Survey is subject to all applicable provisions of the Sewer Use Ordinance of MSD, NPDES No. NC0024911 for the operation of the Metropolitan Wastewater Treatment Plant by MSD and all applicable State and Federal Regulations. b. A Permit issued in response to this Application/Survey is required for construction and operation of any industrial or commercial wastewater pretreatment facilities and/or continued operation of existing wastewater pretreatment facilities. c. This Application/Survey,a Permit issued in response to this Application/Survey and all reports or information submitted pursuant to l the requirements of such Permit must be signed and certified by an authorized representative of the User. d. The provisions of a Permit issued in response to this Application/Survey are severable and, if any provision of such Permit or the Application/Survey of any provision of such Permit to any circumstances is held invalid,the Application/Survey of such provision to other circumstances and the remainder of such Permit shall not be affected thereby. e. It is the responsibility of each In trial or Commercial User to insure that all sludges generated by the User of a Permit issued in response to this Application/Survey, are managed under applicable sludge management equirements specified in all applicable State and Federal regulations. f. Notice is hereby given that any and all significant violations of provisions of the Sewer Use Ordinance of MSD by the User o a Permit issued in response to this Application/Survey or any other Users of the MSD Sewerag System and a list of resulting enforcement actions taken by MSD will be published each yea# in the local newspaper. For the purpose of this Section, a "significant violation" shall be as defined in Subsection 1.03.68 of the Sewer Use Ordinance of MSD. 2 7. 01DUSTRIAL CATEGORY If your facility employs processes in any of the industrial categories or business activities listed below, place a check beside the category or business activity. (Check all that apply.) a. Industrial Categories (1) ❑Aluminum Forming (27) ❑Metal Finishing (2) ❑Asphalt Manufacturing (28) ❑Metal Molding and Casting (3) El Battery Manufacturing (29) El Mineral and Ore Processing (4) X❑Beverage Bottling (30) El Nonferrous Metal,Form&Powders (5) ❑Canning Foods (31) ❑Nonferrous Metals Manufacturing (6) ❑Carbon Black Manufacturing (32) ❑OCPSF,Organic Chemicals,Plastics,& (7) ❑Cement Manufacturing Synthetic Fiber Mfg. (8) ❑Coil Coating (33) ❑Oil&Gas Extraction (9) ❑Copper Forming (34) ❑Paint Formulating (10) ©Dairy Products Processing (35) ❑Roofing Materials Manufacturing (11) El Electronic Components Mfg. (36) ['Pesticide Manufacturing (12) ❑Electroplating (37) ❑Petroleum Refining (13) ❑Explosives Manufacturing (38) El Pharmaceutical Manufacturing (14) El Feedlots (39) El Phosphate Manufacturing (15) ❑Ferro Alloy Manufacturing (40) ❑Photographic Developing (16) El Fertilizer Manufacturing (41) ❑Plastic Injection Molding and Forming (17) ❑Foundries:Metal Mold&Casting (42) ❑Porcelain Enameling (18) El Glass Manufacturing (43) ❑Printing and Publishing (19) El Grain Mills (44) El Rendering (20) ❑Gum&Wood Chemicals Mfg. (45) El Rubber Manufacturing (21) El Ink Formulating (46) ❑Soap&Detergent Manufacturing (22) El Inorganic Chemical Manufacturing (47) El Textile Mills (23) El Laundry (48) El Timber products processing (24) El Leather Tanning&Finishing (49) El Service (25) ❑Meat Processing (50) ❑X Other—Plastic Blow Molding (26) El Medical Care Operations c. Provide a brief narrative description of the manufacturing,production or service activities your firm performs. Number Description of Activities 4 Receive,process,package,and ship water,juice,and fruit drinks 10 Receive,process,package,and ship fluid milk products 50 Manufacture blow molded plastic bottles 3 7. INDUSTRIAL CATEGORY(Continued) a. Indicate Standard Industrial Classification Number(s)[SIC Code(s)]or North American Industry Classification System(s)[NAICS Code(s)]for all processes(if more than one applies,list in descending order of importance. 2026 2037 3085 b. List chemicals and other materials(both liquid and solid)which are used or stored in containers equal to or greater than 50 gallons. Please include the Safety Data Sheets for each of the chemicals,except for oils. (Attach additional sheets if needed.) Size of #of Containers Size of #of Containers Chemical/Material Container on Hand Chemical/Material Container on Hand See Attached Information 8) SOURCES OF WATER a) Source of Incoming Water Gallons Per Day (GPD) Metered 1) City 179,000 GPD ❑X 2) Well or Spring 1,200 GPD ❑X 3) Surface Water GPD 4) Other GPD ❑ Specify: b) Name of Water Agency: City df Asheville c) Name on Water Bill Account: Milkco,Inc. d) Water Bill Account Number: 1010138 1495248 Meter Number Meter Size inches) 70264057 4" 70149383 6" • 70089388 2" 12729641 5/8" 4 9. DISPOSITION OF WATER a) How Water Leaves the facility(Gallons Per Day,GPD) Type of Spring or Surface Disposition City Well Water Other Metered Estimated 1) Sewer 144,000 ❑X ❑ 2) Storm Drain I I ❑ 3) Ground I I ❑ 4) Incorporated in Product 10,000 1,200 X ❑ 5) Waste Hauler ❑ 6) Septic Tank _ ❑ 7) Evaporation 25,000 n ❑X 8) Total(1)through(7) 179,000 1,200 10. SPECIFIC USES OF WATER IN THE FACILITY a) Identify the Uses of Incoming Water (Gallons Per Day,GPD) Use Amount(GPD) Metered Estimated 1. Domestic (Restrooms) 4,643 X 2. Boiler make-up 2,000 x 3. Cooling Water,Non-contact 20,000 X 4. Cooling Water,Contact I I 5. Processing Product 11,200 I I X 6. Washdown of Plant and/or Equipment 141,157 I _X 7. Air Pollution Control Unit I I I I 8. Other (specify) I I I I 9. Total(1)through(8) 179,000 11. BUSINESS HOURS AND NUMBER OF EMPLOYEES a. Days per week that the facility is open for operations: 7 b. Number of Employees: 260 1" Shift 2 Shift 3'Shift Number of Hours 8 8 8 Average#of Employees 135 74 51 Start Time 5:00am 1:30pm 9:00pm 5 12. INDUSTRIAL WATER USES If any water is used for purposes JO.Al 4.Through 10.Al 8.,please complete Section 12. a) A daily average flow limit based on a 30-day period and a maximum 24-hour flow limit will be issued in the permit to Discharge Industrial Waste based on the information submitted below. b) A daily average concentration limit based on a 30-day period and a maximum 24-hour concentration limit for Biochemical Oxygen Demand(BOD)and for Total Suspended Solids(TSS)will not to be exceeded during the period of the Permit. 1) Total discharges including sanitary wastes for which a Permit to Discharge Industrial Waste is requested: Currently During the Period of Upcoming Permit Daily Average Maximum Based Daily Average Maximum Based Based on 30- on 24-Hour Based on 30-Day on 24-Hour Period Day Period Period Period Flow (GPD) .144 .200 .175 .200 BOD (mg/1) * 2374 4500 2400 4500 TSS (mg/1)* 543 2000 550 2000 Oil and Grease(mg/1)* N/A N/A N/A N/A (*If known) 2) Are any process changes or expansions planned during the next 5 years,which would alter wastewater volumes or characteristics? ®Yes ❑No 3) If yes,briefly describe these changes and their effects on the wastewater volume and characteristics: (Attach additional sheets if needed) We project approximately 1% growth per year over the next 5 years which will result in increased wastewater flow. 6 13. PROCESS WASTES a. Are any liquid wastes,by-products,material residues or sludges from this facility disposed of by a means other than discharging to the MSD sewer lines? ®Yes (If"yes",complete items 13.b.,c.,d. and e.) ❑No(If"no",skip remainder of Section 14.) b. These wastes may best be described as: Estimated Gallons or Generated Pounds Per Year Wastes Description Generated Acids Alkalies Heavy Metal Sludges Inks/Dyes Oil and/or Grease Waste Oil <2,000 Gallons Organic Compounds Paints Pesticides Settleable Residues Solvents Other Hazardous Wastes By-Products Other Wastes c. For the above checked wastes,does your company practice? ,Storage pisnosal nOn-site ❑ Off-site X❑Off-site d. Has an Accidental Discharge Control and Countermeasure Plan been prepared for the facility? ®Yes ❑No 7 14. PROCESS WASTES(Continued) d. Briefly describe the method(s)of storage or disposal checked above. Indicate whether landfill, incineration,resource recovery,contract hauling or RCRA regulated practices. Identify contract parties or facilities involved. Waste oil is collected in 500 Gallon tanks and hauled off site by an authorized oil disposal company. Holston Environmental is the company. r � e. Do any of your substances require Resource Conservation and Recovery Act permits? ❑Yes (If"yes",please specify below.) ® No 8 15. PRETREATMENT Is any water utilized at the facility pretreated before it is discharged to the MSD sewer lines? (Possible water uses requiring pretreatment are: contaminated cooling water, water used for processing product, equipment facility washdown,air pollution control unit) ❑Yes (If"Yes",please complete this section,Section 15.) ❑X No (If"No",skip this section,Section 15.) a) Indicate all pretreatment devices or processes used for treating wastewater or sludge. (Check all that are utilized.) ❑ Activated carbon ❑Ion Exchange ❑ Air stripping ❑Microfiltration ❑Centrifuge/Cyclone Separation ❑Nanofiltration ❑Chemical Precipitation ❑Ozonation ❑Chlorination ❑pH Neutralization ❑Cyanide Destruction ❑Reverse Osmosis ❑Dissolved Air Floatation ❑ Screening ❑Filtration ❑ Septic Tank Silver ❑ Flocculation ❑Recovery Solvent ❑Flow Equalization ❑ Separation Biological ❑ Grease or Oil Separation(Petroleum) p Treatment ❑ Grease Trap(Animal/Vegetable) ❑Ultrafiltration ❑Grit Sedimentation ❑Other* *specify: a) Are major pretreatment operations ❑batch or ❑continuous? b) If the major pretreatment operations are batch,indicate the average number of batches per 24-hour day. c) Is any new or modified pretreatment planned for this facility within the next 5 years? ❑Yes (If"Yes",attach detailed plans and operational descriptions.) ®No d) List raw materials that come in contact with process water. 1) 5) 9) 2) 6) 10) 3) 7) 11) 4) 8) 12) 9 16. OPERATIONS EFFECTING PRETREATMENT c. Is operation subject to seasonal variation? LI Yes ® No d. If"Yes",indicate: (1) Seasonal maximum waste flow I allons per day(GPD)during the months of (2) Seasonal minimum waste flow gallons per day(GPD)during the months of e. Does operation shut down for vacation,maintenance,or other reasons? ❑Yes ❑X No f. If"Yes"indicate period when shutdown occurs: g. List any water recycling processes in use. Type of process Describe h. If a new waste discharge is proposed,describe fully,all materials that will come in contact with water and anticipated volume and characteristics of wastewater and any by-products,materials residues or sludges. 10 17. MONITORING a. Sewer connection and discharge information: (1) Provide a simple 8 V2"x 11"drawing or sketch of the total plant area showing a flow diagram of the sewer lines indicating pipe sizes,type of discharge they are carrying manufacturing processes. Also show streets,alleys,streams,manholes,and sewer sampling points. Label each sewer outlet from building as Pipe 1,Pipe 2,etc.and the monitoring point at MP 1,MP 2,ect. (2) Is there an existing sump(s)or manhole(s)on the premises where wastes(industrial waste other than sanitary waste)can be sampled and flow measured? ❑X Yes ❑No (3) Describe the physical properties of the wastewater to be discharged. Characteristic Description Temperature 60-90 Degrees Color Clear to Brownish Clarity Slight Turbid Visible Particulates Miniscule b. Permits and Wastewater Analyses (1) List all environmental permits. (i.e.:NPDES,air,storm runoff) Type of Permit Permit Number Expiration Date NC Stormwater Discharge NCG 060000 10/31/17 WNC Regional Air Quality Control Agency 11-587-15 01/31/23 (2) Have your wastes been sampled by MSD or the North Carolina Department of Environment,Health,and Natural Resources? ❑X Yes ❑No (3) If"Yes",then when was the last date? 03/25/16 c. If any chemical wastewater analyses have been performed on the wastewater discharge(s)from your facility,attach a copy of the most recent data to this application.Be sure to include the date of the analysis,name of laboratory performing the analysis,and location(s)from which sample(s)were taken (attach sketches,plans,etc.,as necessary). 11 18. WASTE CHARACTERIZATION a. Priority Pollutant Information:Please indicate by placing an" "in the appropriate box by each listed chemical that is in your manufacturing or service activity or_generated as a by-product. Concentration EPA Check if Check if Check if Check if in Discharge Chemical Name STORET Present Absent Present in Absent in if Known Code at Facility at Facility Discharge Discharge (mg/1) Acid Extractable Organics 2-Chlorophenol 34586 ❑ 0 ❑ ❑X 2,4-Dichlorophenol 34601 ❑ 0 ❑ 0 2,4-Dimethyphenol 34606 ❑ 0 ❑ ❑X 2,4-Dinitrophenol 34616 ❑ 0 ❑ 0 2-Methyl-4,6-dinitrophenol 34657 ❑ ❑X ❑ 0 4-chloro-3-methylphenol 34452 ❑ ❑X ❑ 0 2-Nitrophenol 34591 ❑ 0 ❑ 0 4-Nitrophenol 34646 ❑ 0 ❑ ❑X Pentachlorophenol 39032 ❑ 0 ❑ 0 Phenol 34694 ❑ ❑X ❑ 0 2,4,6,-Trichlorophenol 34621 ❑ 0 ❑ 0 Base Neutral Organics 1,2,4-Trichlorobenzene 34551 ❑ © ❑ ❑X 1,2-Dichlorobenzene 34536 ❑ 0 ❑ 1,2-Diphenylhydrazine 34346 ❑ ❑X ❑ ❑X 1,3-Dichlorobenzene 34566 ❑ [] ❑ 0 1,4-Dichlorobenzene 34571 ❑ [] ❑ El 2,4-Dinitrotoluene 34611 ❑ ❑X ❑ 2,6-Dinitrotoluene 34626 ❑ ❑X ❑ 2-Chloronaphthalene 34581 ❑ © ❑ 3,3-Dichlorobenzidine 34631 0 X❑ ❑ HI 4-Bromophenyl phenyl ether 34636 ❑ 0 ❑ X❑ 4-Chlorophenyl phenyl ether 34641 Cl ® ❑ Acenaphthene 03405 ❑ ❑X ❑ X❑ Acenaphthylene 34200 ❑ IM r ❑ Anthracene 34220 ❑ ❑X ❑ X❑ Benzidine 39120 ❑ ❑ X❑ Benzo(a)anthracene 34526 ❑ X❑ ❑ X❑ Benzo(a)pyrene 34247 ❑ X❑ ❑ 0 Benzo(b)fluoranthene 34230 ❑ ® ❑ Benzo(ghi)perylene 34521 ❑ ® ❑ 12 18. WASTE CHARACTERIZATIONS (Continued) Concentration Chemical Name EPA Check if Check if Check if Check if in Discharge STORET Present Absent Present in Absent in if Known Code at Facility at Facility Discharge Discharge (mg/1) Base Neutral Organics (continued) Benzo(k)fluoranthene 34242 ❑ ❑X ❑ 0 Bis(2-chloroethoxy)methane 34278 ❑ M ❑ 0 Bis(2-chloroethyl)ether 34273 ❑ ❑X I I X❑ Bis(2-chloroisopropyl)ether 34283 ❑ 0 ❑ Bis(2-ethylehexyl)phthalate 39100 n ❑X Li 0 Butyl benzyl phthalate 34292 ❑ ❑X ❑ 0 Chrysene 34320 ❑ 0 ❑ 0 Di-n-butyl phthalate 39110 ❑ 0 ❑ 0 Di-n-octyl phthalate 34596 ❑ 0 ❑ 0 Dibenzo(a,h)anthracene 34556 n n ❑ X❑ Diethyl phthalate 34336 ❑ n ❑ 0 Dimethyl phthalate 34341 ❑ n ❑ 0 Fluoranthene 34376 ❑ 0 ❑ 0 Fluorene 34381 ❑ 0 ❑ X❑ Hexachlorobenzene 39700 ❑ X ❑ 0 Hexachlorobutadiene 34391 ❑ 0 ❑ X❑ Hexachlorocyclopentadiene 34386 ❑ 0 ❑ X❑ Hexachloroethane 34396 ❑ 0 ❑ 0 Indeno(1,2,3-cd)pyrene 34403 ❑ 0 ❑ ❑X Isophorone 34408 ❑ 0 ❑ 0 N-nitroso-di-n-propylamine 34428 ❑ ❑X ❑ 0 N-nitrosodimethylamine 34438 ❑ X❑ ❑ 0 N-nitrosodiphenylamine 34433 ❑ 0 ❑ 0 Naphthalene 34696 ❑ 0 ❑ X Nitrobenzene 34447 ❑ X❑ I I 0 Phenanthrene 34461 ❑ , 0 ❑ 0 Pyrene 34469 ❑ 0 ❑ 0 Metals Aluminum 01104 ❑ ❑X ❑ 0 Antimony 01097 ❑ l ❑ 0 Arsenic 01002 ❑ ❑X ❑ 0 Beryllium 01012 ❑ [I ❑ 0 Cadmium 01027 ❑ 0 ❑ 0 13 Chromium 01034 ❑ 0 I ❑ 0 18. WASTE CHARACTERIZATIONS (Continued) Concentration Chemical Name EPA Check if Check if Check if Check if in Discharge STORET Present Absent Present in Absent in if Known Code at Facility at Facility Discharge Discharge (mg/I) Metals (continued) Copper 01042 N n N N Lead 01051 N N El N Mercury 71900 El N El N Molybdenum 01062 N N ❑ N Nickel 01067 ❑ N N N Selenium 01147 ❑ N El N Silver 01077 ❑ N ❑ N Thalium 00982 ❑ N ❑ N Zinc 01092 ❑ N ❑ N Inorganics Barium 01007 ❑ 0 N X❑ _ Chloride 00940 N N ❑ N - Cyanide 00720 ❑ NX El XN Fluoride 00951 ❑ N ❑ X❑ Purgeable Volatile Organics 1,1,1-Trichloroethane 34506 ❑ 0 ❑ 0 1,1,2,2-Tetrachloroethane 34516 El 0 El N 1,1,2-Trichloroethane 34511 El 0 El N 1,1-Dichloroethane 34496 N 0 ❑ X❑ 1,1-Dichloroethylene 34501 El 0 El N 1,2-Dichloroethane 34531 ❑ 0 El N 1,2-Dichloropropape 34541 ❑ 0 ❑ 0 2-Chloroethyl vinyl ether 34576 El 0 ❑ 0 Acrolein 34210 _ El M 0 Acrylonitrile 34215 N 0 ❑ 0 Benzene 34030 El 0 ❑ 0 Bromodichloromethane 32101 ❑ 0 N 0 Bromoform 32104 El 0 N 0 Bromomethane 34413 ❑ 0 ❑ 0 Carbon tetrachloride 32102 N 0 ❑ 0 Chlorobenzene 34301 ❑ 0 ❑ N Chloroethane 34311 N 0 ❑ 0 Chloroform 32106 N 0 ❑ 0 Chloromethane 34418 El 0 El N cis 1,3-Dichloropropene 34704 El 0 ❑ N Dibromochloromethane 32105 ❑ 0 ❑ N Ethylbenzene 34371 ❑ ❑X N 0 Methylene chloride 34423 El NX N 0 14 Tetrachloroethylene 1 34475 I ❑ I ® I ❑ I ® I 18. WASTE CHARACTERIZATIONS (Continued) Concentration Chemical Name EPA Check if Check if Check if Check if in Discharge STORET Present Absent Present in Absent in if Known Code at Facility at Facility Discharge Discharge (mg/1) Purgeable Volatile Organics (continued) Toluene 34010 ❑ ❑X ❑• _ M trans 1,3-Dichloropropene 34699 ❑ N ❑ _ M trans-1,2-Dichloroethylene 34546 ❑ ❑X ❑ ❑X - Trichloroethylene 39180 C] ❑X ❑ ❑X - Trichlorofluoromethane 34488 ❑ © ❑ NI _ Vinyle chloride 39175 ❑ © ❑ CI Others Xylene I 81551 I ❑ I ® I ❑ I ® I 19. EXECUTION OF APPLICATION I, Rhett Flanders (print name), Operations Manager (print title), certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information submitted is,to the best of my knowledge and belief,accurate and complete. I am an authorized representative of the user and am authorized to execute this certification on behalf of the user. I am aware that there are significant penalties for submitting false information in violation of this certification,including the possibility of fines and/or imprisonment. I also certify that I have completed the necessary notification as required by the POTW to document my qualification as an Authorized Representative as set forth in 40 CFR Part 403.12(1)and the Metropolitan Sewerage District's Sewer Use Ordinance Section 1.03.04. Xii-ai/4-1.—. 6130 Authorized Signature: * ate *Authorized signature must correspond to Item 2 or 3 from Page 1 of this Application. 15 Chemical List Requiring SDS's for MSD Permit 2016 Size of # Of Containers Chemical Name Container On Hand AC-103 1,500 Gallons 1 50 Gallons 2 Anhydrous Ammonia 38,200 Pounds - Closed System 1 Conden-SAF 2800 55 Gallons 1 DOWFROST Heat Transfer Fluid 1,300 Gallons - Closed System 1 55 Gallons 8 Dryexx 55 Gallons 3 Enforce LP 55 Gallons 5 Envirocid Plus 55 Gallons 5 Exelerate 320 55 Gallons 6 Foam Shine 55 Gallons 2 General Purpose Degreaser 55 Gallons 2 Mandate Plus 55 Gallons 2 Oxonia Active 1,000 Gallons 1 300 Gallons 3 50 Gallons 8 Petrothene LM600700 100,000 Pounds 2 Principal 2,500 Gallons 1 55 Gallons 3 Soil Off II 55 Gallons 2 Ster-bac Quat 55 Gallons 7 Ultrasil'63 55 Gallons 2 Ultrasil 75 55 Gallons 2 Ultrasil 110 55 Gallons 2 Ultrasil MP 55 Gallons 2 Vektor'100 55 Gallons 3 XY12 55 Gallons 6 Chemical List Not Requiring SDS's for MSD Permit 2016 Citgo A/W Hydraulic Oil 32 55 Gallons 1 Citgo No. 2 Diesel Fuel Oil, Low Sulfui• 10, 000 Gallons 1 2,500 Gallons 1 500 Gallons 1 Frick Oil 3 55 Gallons 1 Mobil DTE Oil BB 55 Gallons 3 Mobil SHC 636 55 Gallons 2 Unleaded Gasoline 500 Gallons 1 DEAVERVIEW ROAD N. MILKCO, INC. B E A R R PIPE 01 • SANDFILTER B„ MANHOLE E -• E K R SANDFILTER 0 • MANHOLE A WEIR D I PIPE 01 MONITORING POI! SANITARY SEWAGE MANE