Loading...
HomeMy WebLinkAboutNC0024911_Industrial User_20180525 (4) \S" PN SEW fg4QF Metropolitan Sewerage District • ,-- • OF BUNCOMBE COUNTY,NORTH CAROLINA e 4jBF VP ° 'JNTY NOAH May 23, 2018 Deborah Gore PERCS Unit Supervisor 1617 Mail Services Center RECEIVED/DEN Raleigh, NC 27699-1617 R/CvR MAY 2 5 2018 Re: NOV-2018-PC-0161 Water Resources Permitting Section Dear Ms. Gore: Although I have yet to receive a hardcopy of your letter of Notice of Violation issued to MSD Pretreatment Program dated May 16, 2018, I am responding to the one received via email on Monday, May 21St. Needless to say, MSD's management was stunned to learn of the omission of required documents and is pursuing immediate action to correct this. Our intentions are to send all documents by the June 15th deadline. I am enclosing with this letter thirteen signed copies of SIU permits, permit rationale and applications. In all, of the 20 permitted SIUs only six permits remain outstanding. We take this matter very seriously and will conduct a thorough investigation on how this normal administrative process could have been overlooked. And rest assured that follow up measures will be taken to make sure this will not happen again. In the meantime, please direct all future correspondence to my direct attention. As we continue to work to get the requested information together should you have any questions,you may contact me on my direct line (828) 225-8225. ctfu,Y, Monty lyne Field Operations Manager, MSD Metropolitan Sewerage District, BC 2028 Riverside Dr. Asheville, NC 28804 CC: Thomas E. Hartye, P. E., MSD Peter C. Weed, MSD Roger Edwards, MSD Vivien Zhong, PERCS Unit Linda Wiggs, ARO Protecting Our Natural Resources- 2028 RIVERSIDE DRIVE, ASHEVILLE,NORTH CAROLINA 28804 TELEPHONE:(828)254-9646 FAX:(828)254-3299 WEBSITE:www.msdbc.org Qo�\�OA SEWEps� 0 Metro olitan Sewerage' District _¢ OF BUNCOMBECOUNTY,-NORTH CAROLINA * - `/ Qo BOUNTY.t4 '" - ' • December 5,2016 • Mr.Isao Yoshida,President Mr..Carroll Morgan,Pickling Engineer. • ' Blue Ridge Metals Corporation, Post Office Box 189 Fletcher,North Carolina 28732. RECENED/DE IRIDWR. MAY 252018 Re:•Renewal-Permit to Discharge Industrial Wastewater Permit Number S-060-17 Water Resources • Permitting Section Dear Gentlemen: Pursuant to the Application for of Permit to Discharge Industrial Wastewater dated September 15, • 2011,we are enclosing herewith your Permit to Discharge Industrial',Wastewater. Please note that effective date of this Permit will be January 1,'2017., If you have any comments concerning this.Permit, please • 'advise in writing no tater than thirty(30)days following receipt of this letter.. , •:. - . . :The conditions and requirements included'in the Permit,the Permit Application and MSD Sewer ' Use•Ordinance(SIIO)are integral parts of this Permit ": - . This permit is valid until December 31,2021.•If there isa significant change in,your wastewater • . discharge as defined in Sections'4.03 of the MSD Sewer•Use Ordinance; or your facilities are reassigned,' • transferred,or solato a new user,a new permit application mi st.b`e sub mitted to MSI)at least one hundred _ - .. and eighty(180)'days prior to any the above events: . . - Sincerer, . s- . , 4,,„,.--j2;,, • '' ?„, ' ,,'fihomas E•.Hartye;P:E:. . . General' Manager - • , -Protecting Our Natural.Resources- ' • 2028 RIVERSIDE DRIVE, ASHEVILLE,NORTH CAROLINA 28804 TELEPHONE:(828)254=9646 :PAX:(828)254-3299 WEBSITE:www.msdbc:org , THE METROPOLITAN SEWERAGE DISTRICT • OF BUNCOMBE COUNTY,NORTH CAROLINA QoJ�PN SEW594Qe • Q � '00„„„,,,00°NNNiY,NORM' PERMIT TO DISCHARGE INDUSTRIAL WASTE FOR SIGNIFICANT INDUSTRIAL USER Permit No. S-060-17 , 40 CFR Category:420,96 and 420.126 In accordance with all terms and conditions of the Sewer Use Ordinance (SUO) of the District Board of the Metropolitan Sewerage District of Buncombe County, North Carolina (MSD), NPDES Permit No. NC0024911 for the operation of the Metropolitan Wastewater Treatment Plant by MSD,North Carolina General Statute 143-215.1, and other lawfulstandards and regulations promulgated and adopted by the North Carolina Environmental Management Commission and the District Board of the Metropolitan Sewerage District of Buncombe County, North Carolina: • PERMISSION IS HEREBY GRANTED TO: Blue Ridge Metals Corporation • 180 Mills Gap Road Fletcher,North Carolina.•28732 . . FOR THE _ operation of industrial wastewater pretreatment facilities as specified in this Permit and the discharge of wastewater from sanitary facilities and process facilities classified by Standard Industrial-Classification(SIC) Code Nos.3452 and 3315 into the District Sewerage Systemof the Metropolitan Sewerage System at 180 Mills Gap Road, Fletcher, North Carolina 28732. The discharge shall be in accordance with effluent limitations, monitoring requirements and other conditions set forth in this Permit to Discharge industrial Waste(the"Permit"). • Effective this 1st day of January,2017 This Permit expires the 31st day of.December,2021. - METROPOLITAN SEWERAGE DISTRICT OF • BUNCOMBE COUNTY,NORTH CAROLINA ! �-- /7.442 0 Thomas Fakiftye;P.E. Date General Manager . . 1 • • • Permit No. S-060-17 PART I .OPERATION AND CONSTRUCTION OF FACILITIES FOR THE PRETREATMENT OF INDUSTRIAL.WASTEWATER • A. Continued operation of the industrial wastewater pretreatment facilities below is hereby approved subject to the conditions and requirements contained in the Permit and the MSD Sewer Use Ordinance. • 1. Flow Equalization 2. Chemical Precipitation 3. Flocculation 4. Clarifier 5. Thickener 6. Filter Press 7. Neutralization,pH Correction B. Construction and operation of the additional industrial pretreatment facilities set forth below is • hereby approved. Not Applicable C. Permit Modification History July 1,1989 Permit to Discharge issued. February 28,1991 Renewed Permit March 1,1994 Renewed Permit . August 26,1995 Amended Permit to reflect an allocation of additional flow from 0.045 MGD to 0.055 MCD (Monthly Average). . • December 19,1996 Extended Permit to Discharge from March 1,1997.to March 1,1999 March 1,1999 . Renewed Permit. No. S-060-91 as S-060-99 to Blue Ridge Metals Corporation. . July 1,2001 Removed the BOD and TSS limitations and monitoring requirements. In addition, reduced MSD's,monitoring frequency to ' one(1) time per six(6)months January 1,2002 Renewed Permit, S-060-99 . as S-009-02 to Blue Ridge Metals Corporation. • January 1,2007 Renewed Permit S-060-02 as S-060-07 to Blue Ridge Metals Corporation - May 1,2008 Amended aerial photograph and description of pipes. January 1,2012 Renewed Permit January 1,2017 Renewed Permit • • • 2 Permit No. S-060-17 1 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS A. Description of Discharge(s) Pipe No. Description 01 Pretreated Wastewater from Pickling,Air Scrubbers and Plant Wash-Down 02 Domestic Wastewater 03 • ' Total Facility. Discharge • Monitoring Point Description MP01 Effluent discharge from pretreatment facility Site Layout 23588 - --- -_ ------23587 -___- Ena---- --__ Pipe 0 ,, f'' . __ „ii . .. ,. .. ., ‘ , r Pip- 0'2. :P ' 1 , r . t • J 'T � Pipe 01 Nc, r 4'4 "\ / .? S. t + ° ,i I _ . a }�,: ._. ` ,G l -- ar 4 MP Ol ' ,i - t �. 1 M I ' 4I . ... • 'Discharge at Pipes 02 & 03 may be monitored periodically and unannounced by MSD to assess compliance. Prior to any discharge of process wastewaters into these pipes, a Permit Application must be submitted to the MSD and a new Permit issued. 3 Permit No. S-060-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS Monitoring Point 01 r ---' 1 i - --.I. ' .:... _ _6......• - , f2fr ini . . . i _ e NIP 01 tE . i-• -; , I: ---"I 3 . r ill I V --.--, •' [e i.,., A ' • ! 1 . 1r ••_, . , __ ..„..,....,..- • -_. i„. ,; „'„,-vg i .,, it. . , ? 7.14,•-•.es — _ 4, •--- 444„..,__ , . ,•-,, tfl„.....,,......v,„,...? .---•- .4 ,,..• __. , a... . . , •.. . "- - *. '&.._...,_ --` -ii---4ii, k i . - . '... , . . _ •A ,h , _ _ ,. • . 0$ . ., .. - . • • , % I ..,,.. . , , -,* , , . 4 • li.„4 . . .. ., ... . .. lir*, .' '.i*k i I t, • 4%,' : ' \''4'.‘ . r - , .• ,r ' \ . ..,. ..„ ,.... . .. ,,,,,,,, . , . . , . , . . . . - . . , . . . 4 Permit No. S-060-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS S. Effluent Limitations Effective immediately and lasting until the expiration of the Permit, the Industrial User is authorized to discharge process waste to Pipe No. 01. The pretreatment facility is a continuous operation and the discharge shall be limited and monitored at MP 01, based on Production Rates*,as specified below: EFFLUENT LIMITATIONS Limited Daily Monthly Sample Monitoring Frequency Parameter Maximum Average • Units. Type MSD Industry Flow ' 0.100 0.075: • MGD Continuous Once/Year Daily pH 6.0 to 10.5 6.0 to 10.5 Std.Units . Grab Once/Year Daily Lead • 0:529 • 0.176 •lbs/day Composite Once/Year Once/Week** • Zinc 0:703 0235 " lbs/day Composite Once/Year Once/Week * Production Rates:See Part II,Section D.3: *',Monitoring Relief:See Part II,Section C.10. • • C.` Effhtent'Monitoring Conditions • 1. The scheduled monitoring frequencies are minimum requirements and may be adjusted by.MSD. 2. Flow is in million gallons per day (MGD). The permitted flow is monitored at the end :of the pretreatment system and the flow meter is to be calibrated or changed out on an annual bases. A copy of the calibration report is to be submitted to MSD with the subsequent Monthly Monitoring Report. 3. The pH shall be not less than 6.0 or greater.than'10.5 standard units. Deviations from these limits shall be handled in accordance with MSD Pretreatment Program Guidance Policy, . 4. Where continuous pH recording equipment is utilised,the lowest and highest reading shall be taken from a 24 hour chart. The reading closest to the pH range limits,is the reading to report on the Monthly.Monitoring Report. 5. - Discharge•of Parameters not specifically limited in this Part is limited to Domestic Sewage Levels as established by the District's Sewer Use Ordinance. • 5 Permit No. 5-060-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS 6. No .dilution, such as unregulated process wastewater, domestic or non-process wastewater shall be introduced into Pipe 01 as identified in the Site Layout on Page 3 of the Permit. 7. Continuous and composite samples shall be at least twelve (12).portions collected • during a twenty-four (24) hour period or the total duration of waste discharge if less than twenty-four(24)hours. Alternate sampling requirements may be established in a User's.Permit to Discharge Industrial Waste or by the General Manager. 8. A "grab" sample, for monitoring requirements, is defined as a single "dip and take" sample collected at a representative point in the discharge stream. 9. An instantaneous measurement, for monitoringrequirements, is defined.as a single reading,observation,or measurement. 10. The first self-monitoring report•during each Semiannual Reporting Period(i.e.January and July of each year) shall be analyzed for all limited parameters except TTO. If the following conditions are met: • a. Parameter is not used in process operations and b. The analysis show the concentration to be below 0.01 ppm no further monitoring during that six months will be. required unless process operations ,change which could indicate the possible introduction of the limited parameters not previously discharged.. In addition each subsequent Monthly Monitoring Report, for the remainder of the Semiannual Reporting Period, shall be supplemented with the_following statement: . • "The heavy metal .) listed below and not found in the process waste discharge during he last prior analyseshave not been subsequently introduced into p ' t process operations." • . 6 Permit No. S-060-17 PART II • EFFLUENT LIMITS AND MONITORING REQUIREMENTS D. Monitoring and Reporting ' 1. Representative Sampling • a. Samples and measurements taken as required herein shall be representative of the • volume and nature of the monitored discharge. All samples shall be taken from Pipe numbers specified in the Permit and, unless otherwise specified, before the effluent joins or is diluted-by any other wastestream,body of water, or substance. Pipe numbers shall not be changed without notification to and approval by MSD. b. Samples must be collected and composite (a minimum of twelve portions) over an entire operating day. Where weekly samples are required;a progressive schedule • will be used,Monday one week,Tuesday the next,etc. - c. Test procedures for the analysis of pollutants shall be performed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto unless . specified otherwise in the monitoring conditions of the Permit. • d.' All records of analysis and measurement performed by the Industrial User must be retained by the Industrial User for three(3)years. • • 2. Reporting • -a: Monitoring.results obtained by the Industrial User shall be reported on the Self- . Monitoring Monthly Report Forms on MSD's website with signed hardcopies of the Forms and supporting lab.analyses postmarked no later than the twentieth day.of the month following the month in which the samples were taken. If no discharge occurs during the reporting period, "no discharge" shall be indicated on the.Forms. Copies of these and contract laboratory reports.shall be faxed, emailed otsubmitted to the'MSD at the following address: • • Attention: Industrial Pretreatment Coordinator Metropolitan.Sewerage District . • 2028 Riverside Drive • Asheville,North Carolina 28804 . • • b. . In the event of an accidental discharge,slug loading or self-monitoring indicating non-compliance with the SUO or the Permit,the Industrial User shall notify MSD , within 24 hours of becoming aware of the violation by using the Report Forms on • MSD's Self-Monitoring Monthly Report Form website. • • • • 7 • Permit No. S-060-17 PART II EFFLUENT LIMITS AND MONITORING REQUIREMENTS D. Monitoring and Reporting(continued) c. If the accidental discharge, slug loading, or self-monitoring is suspected of severely impacting the MSD sewer system endangering public safety or the safety of MSD employees, the Industrial User shall immediately notify MSD by telephone of the non-compliant event. The telephone numbers to contact are: • Tillie and Days. Contact Telephone Number 8:30 am to 4:30 pm,Monday-Friday Industrial Pretreatment Coordinator (828)254-9646 after 4:30 pm,weekends,and holidays Operator on duty (828)225-8228 d. Within five (5) days of the accidental discharge, slug loading or other non- compliant oncompliant discharge, a written report by the authorized representative of.the Industrial User, shall be submitted to the General-Manager of the MSD. The report must include as a minimum: (i) The date, time and duration of the accidental discharge, slug loading or discharge not in compliance with conditions and requirements of the SUO or the Permit; (ii) The quantity and waste characteristics of the discharge; (iii) The corrective action taken to prevent future accidental discharges, slug loadings or discharges not in compliance with the SUO or the Permit. e. If self-monitoring by an Industrial User indicates a violation, the Industrial User shall repeat the self-monitoring and analysis and submit the results of the repeat analysis to MSD within thirty (30) days after becoming aware of the violation. The requirements of this paragraph are in addition to the requirements set forth in subparagraphs b.,c.,and,d.of this Part. . 3. Production Rates • The term Production Rates shall mean the tons of Wire and Metal Parts processed whichcontribute wastewater treated at the facility. This information shall be used for. the purpose of determining pollutant Effluent Limits.:Monthly production rates from the previous year shall be maintained and reported to MSD.on an annual basis. The report is to be submitted with the January's Self-Monitoring Report. • 8 Permit No. S-060-17 PART III GENERAL CONDITIONS AND REQUIREMENTS A. Duty to Comply The Industrial User must comply with all conditions of the Permit. Any non-compliance. with the Permit constitutes a violation of the SUO and may be grounds for possible enforcement action. The MSD may levy fines of up to twenty-five thousand dollars ($25,000.00)per day per violation. The Industrial User may be subject to criminal penalties levied by the State of North Carolina or the United States of America. B. Duty to Mitigate-Prevention of Adverse Impact The Industrial User shall take all reasonable steps to minimize or prevent any discharge in violation of the Permit which has a reasonable likelihood of adversely affecting human health,the MSD Treatment Plant,the French Broad River,or the environment. C. General Prohibitive Standards In addition to the requirements of the Permit,,the Industrial User shall comply with the • general prohibitive discharge standards in 40 CFR 403.5(a) and (b) of the Federal • pretreatment regulations: D. :Facilities Operation The Industrial User shall at all times maintain in good working order and operate as efficiently as possible, all control facilities or systems installed or used by the Industrial • User to achieve compliance with the terms and conditions of.the Permit and the SUO. E. Bypass 1. Bypass of treatment facilities is prohibited. MSD may take enforcement action against 'the Industrial User for bypass unless MSD, approves when. such bypass is in compliance with 40 CFR 403.17: Such conditions are: a. Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; • b. .There were no feasible alternatives to the bypass. This condition is not satisfied if adequate back-up equipment `should have been installed in the 'exercise of reasonable engineering judgment to prevent a bypass which occurred during ' normal periods of equipment downtime or preventative maintenance;and c: The Industrial User knows in advance of the need for the bypass; submits prior notice of the bypass to MSD. 9 • Permit No. S-060-17 PART III GENERAL CO DITIONS AND REQUIREMENTS • 2. If the Industrial user does not know of the bypass in advance, it must submit verbal notice to MSD as soon-as e Industrial User becomes aware of the bypass. The verbal notice shall be followedfrith a written submission. The written submission shall describe the bypass and its cause; state how long the bypass occurred'including exact • • dates and times, and if tl-e bypass has not-been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate and prevent reoccurrence of the bypass. F. Flow Measurement . . 1. Flow measuring and recording facilities shall be maintained to provide an accurate • measurement,of the volume discharged. If it is the determination of the MSD that when,in the opinion of the MSD Or Industrial User,the flow measuring and recording facilities are not sufficiently measuring the flow,the MSD may require recalibration or change-out at the expense of Industrial User. - 2. Any malfunction of flow monitoring and recording equipment shall be reported by the Industrial User.immediately to MSD.by phone-followed by a written"report submitted • to the General-Manager of MSD within five (5) days of the malfunction. Any malfunction must be corrected within seven(7) days. Certification of accuracy must be . , provided to MSD within fifteen(15) days of the date of repair.. . G. Reports of Changed Conditions 1. The Industrial Usershall give notice to the' General Manager of any planned significant changes to the operations or system which might alter the nature,quality, • or volume of its wastewater at least 180 days before the change. The Industrial User. shall not begin the changes until receiving written approval from MSD. Significant changes may include but are not limited to the following: . a. increases or decreases to production; • b. increases in discharge of previously reported pollutants; c. discharge of pollutants not previously reported; • d. new or changed product lines; e. new or changed . ufacturing processes.. ' 2. Discharge of wastewater 'th changes as indicated above shall not begin until a Permit to Discharge Industrial Waste has been,issued by MSD for the proposed discharge or until MSD amends an exis: g Permit. V . • • • 10 V Permit No. S-060-17 PART III GENERAL CONDITIONS AND REQUIREMENTS H. Removed Substances Solids, sludge, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in a manner such as to prevent any pollutants from such materials from entering the sewer system. The Industrial User is responsible for assuringits compliance with ;any requirements regarding the• generation, treatment, storage, or disposal of "Hazardous Waste" as defined under the Federal Resource Conservation and Recovery Act. . Upset Conditions . An "Upset" of Pretreatment Facilities means an exceptional incident in which there is an unintentional and temporary noncompliance with the effluent limitations of the.Permit because of factors beyond the reasonable control of the Industrial User. An Upset does not include noncompliance to the extent caused by operational error, improperly designed or • inadequate treatment facilities, lack of preventative maintenance, or careless or improper operations. , An Upset may.constitute an affirmative defense for action brought for the noncompliance. The Industrial User has the burden of proof to provide evidence and demonstrate that none of the factors listed in the preceding paragraph were responsible for the noncompliance.. J. Toxic Pollutants If a toxic effluent standard or prohibition (including any schedule of'compliance specified in such effluent standard or prohibition) is established.under Section 307(a) of the Federal Clean Water Act or North Carolina General Statutes 143-215.1 fora Toxic Pollutant which is present in the discharge and such standard or prohibition is more stringent'than any limitation for such pollutant in the Permit, the Permit may be revised or modified in accordance with the toxic effluent standard or prohibition. K. Accidental Discharges and Slug Loads . The Industrial User shall provide protection,from accidental and slug discharges of prohibited materials or other substances regulated by the Permit. 1. Such protection shall include, but is not limited to; the construction of containment dikes,the rerouting of all floor drains in the manufacturing area to a holding area,and the plugging of floor drains. Modifications to the measures shall be approved by MSD prior to installation or implementation. 2. A written contingency plan shall be submitted to 'MSD, which outlines the procedures to be taken by the Industrial User in the event that an accidental spill or leak of a prohibited substance occurs, The plan shall also include notification procedures outlined in Part II,Section D.3.b.,c.,and d. of this Permit. 11 Permit No. S-060-17 PART III GENERAL CONDITIONS AND REQUIREMENTS a. The Industrial User shall review and revise, as needed,the written contingency plan every three (3)years. Description of Plan Submittal Date - Submit revised version of"Spill August,2018 Prevention&Containment Plan for MSD" 3. A Notice shall be permanently posted at a prominent place in the facility for which the Permit has been issued advising employees whom to call in the event of an Accidental Discharge. Users shall insure that all employees who observe or whomay cause or suffer such an Accidental Discharge to occur are advised of the emergency notification procedure. The notification procedure outlined in Part II, Section D.3.b., c., and d. of this Permit shall be followed. . L. Need to Halt or Reduce not a Defense • It shall not be a defense for an Industrial User in an enforcement action that it would have been necessary to halt or reduce the permitted activity to maintain compliance with the conditions of the Permit. • M. Dilution The Industrial User shall not increase the use of potable or process water or in any other way attempt to dilute the discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in the Permit. • N. . Right of Entry The Industrial User shall allow the staff of the Metropolitan Sewerage District, the North Carolina Department .of Environmental and Natural Resources, the Environmental Protection Agency and/or their authorized representatives, upon the presentation, of credentials: 1. Toenter upon the Indusial User's premises where a real or potential discharge is located or in which records'are required to be kept under the terms and conditions of the Permit;and 2. At reasonable times to have access to and copy records required to be kept under the terms and conditions of the Permit;to inspect any monitoring equipment or monitoring method required in the Permit;and to sample any discharge'of pollutants. O. Monitoring Access • MSD, the Approval Authority and, EPA shall have the right to set up on the Industrial User's Property such devices as are necessary to conduct sampling,inspection,compliance monitoring and flow metering operations. 12 Permit No. S-060-17 PART III GENERAL CONDITIONS.AND REQUIREMENTS P. Availability of Records and Reports • The -Industrial User shall retain records of all monitoring information, including all • calibration and maintenance records as well,as copies of reports and information used to complete the application for the Permit for at least three (3)years. All records pertaining to any enforcementaction shall be retained and preserved by the Industrial User until all enforcement activities have concluded and all periods of limitation with respect to any and all appeals have expired. Except for data determined to be confidential under the Sewer Use Ordinance, all reports prepared in accordance with terms of the Permit shall be available for public inspection at the Metropolitan Sewerage District. Effluent data shall not be considered confidential. Q. ..Duty to Provide Information The Industrial User shall furnish to the General Manger or his designees, within a reasonable time, any information MSD, or its designee, or the North Carolina Department of Environment'and Natural Resources may request to determine whether,cause exists for modifying, revoking and reissuing, or terminating the Permit or to determine compliance with the Permit. The Industrial User shall also furnish, upon request; copies of records required to be kept by the Permit. . , R. Penalties for Falsification of Reports The Metropolitan Sewerage District SUO provides that any person who knowingly makes any false statements or representation in any application or report or other. document submitted or required to be maintained pursuant to the SUO or the Permit, or who knowingly renders inaccurate any monitoring device or•. method required under this ordinance, shall upon conviction be punished by a_fine of not more than $25,000 for each violation.' NCCS 143-215.6B provides that similar offenses may be punished by a fine of up to$10,000 per violation. S. Signatory Requirements All reports or information submitted pursuant to the requirements of the Permit must be signed and certified by the Authorized Representative of the Industrial User as specified in the Application for Permit to Discharge Industrial Waste. If the designation of the Authorized Representative is no longer accurate, a new authorization satisfying the requirements of this,section must be Submitted to General Manager prior to or together . . with any reports'to.be signed by the new Authorized Representative. 13 • Permit No. S-060-17 PART III GENERAL CONDITIONS AND REQUIREMENTS T. Civil and Criminal Liability • Nothing in the Permit shall be construed to relieve the:Industrial User from civil or criminal penalties for noncompliance with provisions of the Permit. U. Federal and State Laws Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities,liabilities, or penalties established pursuant to any applicable Federal and State law or regulation. . V. Property Rights The Permit does not convey any property rights'in either real or personal property, or any executive privileges,nor does it authorize any injury to private property or any invasion of personal rights,nor any infringement of Federal,State or local laws or regulations. W. Severability . The provisions of_the Permit are severable and, if any provision of the Permit or the application of any provision of the Permit'to any circumstance is held.invalid, the application of such provision to other circumstances and the remainder of the Permit shall not be affected thereby. X. Re-opener Provision The Permit shall be modified, or alternatively, revoked and reissued, to comply with any applicable effluent standard or limitation issued or approved under Sections 302(b)(2)(C) and(D),304(b)(2) and 307(a)(2) of the Clean Water Act,if the effluent standard or limitation so issued or approved: • 1. Contains different conditions or is otherwise more stringent than any effluent limitation in the Permit;or 2. Controls any pollut t not limited in the Permit. The Permit as modified or r issued under this paragraph shall also contain any other requirements of the Clean Wa,er Act then applicable. 14 • • Permit No. 8-060-17 PART III GENERAL CONDITIONS AND REQUIREMENTS Y. Permit Modification,'Revocation,Termination The Permit may be modified, revoked and reissuedor terminated in accordance with the requirements of the SUO, North Carolina General Statute 143-215.1 and regulations promulgated thereunder. The Permit shall be modified, alternatively or revoked and reissued, to comply with any applicable effluent standard or limitation for the control of any pollutant shown to contribute to the toxicity of the MSD Wastewater Treatment Plant effluent or any pollutant that is otherwise limited by the MSD Discharge Permit The Permit as modified or reissued under this paragraph may also contain any other requirements of State or Federal pretreatment regulations then applicable. Z. Application for Permit Renewal The Industrial User is responsible for filing application for re-issuance of the Permit within one hundred and eighty(180) days of its expiration date. • • AA. Transferability The Permit shall not be reassigned or transferred or sold to a new owner, new Industrial User, different premises or a new or changed operation without the written approval of MSD. Any succeeding owner or Industrial User shall also agree in writing to comply with the terms and conditions of the Permit and shall be provided a copy of the Permit. • BB. Construction • - No construction of pretreatment facilities or additions thereto shall commence until Final Plans and Specifications have been submitted to MSD' and written approval and an Authorization to Construct(A to C)have been issued. • • • • • 15 Permit No. S-060-17 THE METROPOLITAN SEWERAGE DISTRICT OF BUNCOMBE COUNTY,NORTH CAROLINA SEWf 4 TONNTY,NON" PERMIT RATIONALE FOR Permit No. S-060-17 Effective Date: January 1,2017 Expiration Date: December 31, 2021 A. Basic Information 1. Name and Address of User Blue Ridge Metals Corporation 180 Mills Gap Road Fletcher,North Carolina 28732 2. Description of User's Operation i) SIC Code Nos. 3452 and 3315: Drawing and Cold Forming of steel wire to produce automotive industry. ii) 40 CFR Category: 420.96(a)(1) and(5) and 420.126(b)(1) and(c) 3. Name of WWTP Receiving Wastewater Metropolitan Sewerage District of Buncombe County,NC French Broad River Water Reclamation Facility NPDES Permit No.NC 0024911 1 Permit No. S-060-17 B. Rationale For Limitations and Effluent Limits The following pollutants were assigned numerical limits in this Industrial User Permit for Monitoring Point 01 based on the categorical regulations. These limits do not result in over allocation the Maximum Allowable Industrial Loading determined with the Headworks Analysis among all Users. Daily Monthly Pollutants Maximum Average Units Lead 0.529 0.176 lbs/day Zinc 1.040 0.235 lbs/day The Metropolitan Sewerage Treatment Plant is experiencing no difficulty treating the industrial waste it is receiving at this time. Permit limits are based on the current Headworks Analysis, which considers most recent available industrial monitoring and analytical characterization of the MSD Wastewater System. Limits established in Permits to Discharge Industrial Waste were utilized in the Headworks Analysis to determine the capability of the Wastewater Treatment Plant to operate within design and Permit Limits, pass-through and receiving stream Water Quality Criteria, and without chemical inhibition. C. Rationale For Other Pollutants 1. MSD had sampled the effluent from Blue Ridge Metals during the period for Permit S-060-07. The following pollutants, which were detected in the discharge at Monitoring Point 01, were not assigned numerical limits in this Industrial User Peimit. Their concentrations were at or below domestic concentrations. Pollutants Chromium Copper Nickel Tin 2. The following pollutant, which was detected in an analysis of the acid waste, has not been detected in the discharge at Monitoring Point 01. Pollutants Cadmium 2 Permit No. S-060-17 3. The following pollutant is a Priority Pollutant known to be used in the manufacturing process but does not come in contact with process waste water. Pollutants Toluene • 3