Loading...
HomeMy WebLinkAboutWQ0039608_Issuance of Permit_20180521 Central Files APS _ SWP 5/21/2018 Permit Number WQ0039608 Permit Tracking Slip Program Category Status Project Type Non-discharge In review Major modification Permit Type Version Permit Classification Gravity Sewer Extension,Pump Stations,&Pressure Sewer Extensions B Individual Primary Reviewer Permit Contact Affiliation ted Cashion RECEIVE®/DENRI®WR Coastal SWRule MAY 2 5 2018 Permitted Flow 0 Water Resources Permitting Section Facility Facility Name Major/Minor Region Briar Chapel SD East Lift Station Minor Raleigh Location Address County Chatham Facility Contact Affiliation Owner Owner Name Owner Type Old North State Water Company LLC Non-Government Owner Affiliation Michael J Myers 4700 Homewood Ct Dates/Events Raleigh NC 27609 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 12/8/2017 4/25/2018 5/24/2018 5/24/2018 Regulated Activities Requested/Received Events Food preparation,other Additional information requested Hotel/Motel Additional information received Nursing Home Office Restaurant Retail Wastewater collection Outfall Waterbody Name Streamlndex Number Current Class Subbasin ROY COOPER Covet not r. t` MICHAEL S. REGAN ~ F Secretary t�Fr •.4 .,�.� � s�.�s> LINDA CULPEPPER Intel on Do color Water Resources ENVIRONMENTAL QUALITY May 24, 2018 Michael J. Myers, President Old North State Water Company, LLC 4700 Homewood Court, Suite 108 Raleigh, NC 27609 - Subject: Permit No. WQ0039608 Modification Old North State Water Company, LLC Briar Chapel SD East Lift Station Wastewater Collection System Extension Permit Chatham County Dear Mr. Myers: - In accordance with your application received April 25, 2018, we are forwarding herewith Permit No. WQ0039608 Modification dated May 24, 2018, to the Old North State Water Company, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void permit Number WQ0039608 issued December 8, 2017, and shall be subject to the conditions and limitations as specified therein.This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. This modification increases the capacity of the pump station from 400 gpm to 1100 gpm, deletes 3,850 linear feet of 8-inch force main, allows for the construction of 13,830 linear feet of 12-inch force main and 16,400 linear feet of 14-inch force, and allows wastewater to be pumped directly to the wastewater treatment plant. Please pay particular attention to the following conditions contained within this permit: Condition 1.1: Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Condition 11.1: This permit shall not be automatically transferable; a permit modification request for a name change must first be approved by this office. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system-wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as-constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Division of Water Resources,Raleigh Regional Office,Watei Quality Operations Section www.ncwaterquality org 1628 Mail Service Center,Raleigh,NC 27699-1628 Phone (919)791-4200 T,ncation. 1800 Rarrett Drive Raleigh NC 77609 Fax (01 01 7RR-71 cQ Old North State Water Company, LLC Permit No.WQ0039608 Modification •b Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable,you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and-filed with the Office of Administrative Hearings, 6714 Mail-Service Center,—RaleighTNC—� 27699-6714. Unless such demands are made,this permit shall be final and binding. If you need additional information concerning this matter, please contact Ted Cashion at (919) 791-4254 or via e-mail at ted.cashion@ncdenr.gov. Sincerely, for Linda Culpepper Interim Director, Division of Water Resources • by S. Daniel Smith, Regional Supervisor • Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ • cc: Mark P.Ashness, P.E., CE Group (via email: mark@cegroupinc.com) Chatham County Health Department Raleigh Regional Office Files Water Resources Central Files Page 2 of 8 .. North Carolina Department of Environmental Quality STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Old North State Water Company, LLC Chatham County for the construction and operation of approximately 47 linear feet of 8-inch gravity sewer,an 1,100—gallon per minute pump station with duplex pumps,on-site audible and visual high water alarms,telemetry, and a permanent generator with automatic transfer switch, as well as approximately 13,830 linear feet of 12- inch force main and approximately 16,400 linear feet of 14-inch force main to serve future development consisting of restaurants, offices, retail, hotel and nursing home facilities as part of the Briar Chapel SD East Lift Station project, and the discharge of no additional gallons per day (flow will permitted in subsequent permits) of collected wastewater into the Old North State Water Company, LLC's existing sewerage system pursuant to the application received April 25, 2018 and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated in March 2008, as applicable;the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from th- ..te of issn� ce until rescinded and shall be subject to the specified conditions and'l mitations con .'•ed herei. 4.-21 ..--- \ Linda Culpepper T Interim Director, Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0039608 Modification Permit Issued: May 24, 2018 Page 3 of 8 SUPPLEMENT TO PERT COVER SHEET -� Old North State Water Company, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Briar Chapel Wastewater Treatment Facility in accordance with Permit Number WQ0028552. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable; and the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as-constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS 1. Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. [15A NCAC 02T .0305(h)(2)] II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T.0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system-wide collection system permit for the Page 4 of 8 Y operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required,the following performance criteria shall be met: [15A NCAC 02T.0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day(i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High-priority sewer lines shall be inspected at least once per every six-months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. _ g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease-related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs(a)through (i)of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Raleigh Regional Office, telephone number (919) 791-4200, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure,due to known or unknown reasons,that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume,that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement,then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines&force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing,velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided. Page 6 of 8 • y, c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case-by-case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After-construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T.0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case-by-case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T.0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T;the Division's Gravity Sewer Design Criteria adopted February 12, 1996 and updated March 2008, as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Station and-For-ce-tv1ains adopted June 1, 2000 and updated March 2008 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina Genera! Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-licensed Professional Engineer to the licensing board. [15A NCAC 02T.0104; 15A NCAC 02T.0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions,the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T.0110, 15A NCAC 02T.0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules,regulations,or ordinances that may be imposed by the Division any other Federal,State,or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Old North State Water Company, LLC PERMIT#: WQ0039608 Modification PROJECT: Briar Chapel SD East Lift Station ISSUE DATE: May 24, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation -- — —the-Regional Super-visor,Water-Quality-Regional-OperationsSection_at theaddress_at the_bottom.__ Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I,the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name,Title Signature Date ENGINEER'S CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (I I periodically, I I weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that,to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division)Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: n Final Partial (include description) • Certification Comments/Qualifiers (attach if necessary): Division of Water Resources,Raleigh Regional Office,Water Quality Operations Section www.ncwaterquality.org 1628 Mail Service Center,Raleigh,NC 27699-1628 Phone.(919)791-4200 T,,,:,tin 12011 Ro,•rPtt Tlr.,P n.,iP,rri, 1.1r')'7r r1Q Ft-,v• 10101 7RR_'7i sa _ • State of North Carolina Department of Environmental Quality Division of Water Resources DWR • =" 15A NCAC 02T.0300—FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16&SUPPORTING DOCUMENTATION �03g1/0� "Ao� Application Number: �� (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Old North State Water Company,LLC(company,municipality,HOA,utility,etc.) 2. Applicant type: El Individual ❑ Corporation ❑General Partnership ®Privately-Owned Public Utility ❑Federal ❑ State/County ❑Municipal ❑Other 3. Signature authority's name:Michael J.Myers per 15A NCAC 02T.0106(b) Title:President 4. Applicant's mailing address:4700 Homewood Court, Suite 108 NC Dept of Environmental Quality City:Raleigh State:NC Zip:27609- 5. Applicant's contact information: APR 2 5 2018 Phone number: (252)235-4900 Email Address:mmyers@envirolinkinc.com Raleigh Regional Office II. PROJECT INFORMATION: 1. Project name:Briar Chapel SD East Lift Station 2. Application/Project status: ❑Proposed(New Permit) ®Existing Permit/Project If a modification,provide the existing permit number:WQ0039608 and issued date: 12/8/17 If new construction but part of a master plan,provide the existing permit number:WQ00 3. County where project is located: Chatham 4. Approximate Coordinates(Decimal Degrees): Latitude: 35.809°Longitude: -79.090° 5. Parcel ID(if applicable): 18911 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer:Mark P Ashness License Number: 18.894 Firm: CE Group Mailing address:301 Glenwood Avenue,Suite 220 City:Raleigh State:NC Zip:27603- Phone number: (919)367-8790 Email Address:mark n,cegroupinc.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name:Briar Chapel WWTP Permit Number:WQ0028552 Owner Name: Old North State Water Company,LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION(if different than WWTF): 1. Permit Number(s):WQ N/A Downstream(Receiving)Sewer Size: N/A inch System Wide Collection System Permit Number(s)(if applicable):WQCSWQCS00372 Owner Name(s): Old North State Water Company,LLC FORM:FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? ®Yes ❑No EN/A 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM:DEV)been attached? ❑Yes ❑No ❑N/A 3. If the Applicant is a Home/Property Owners'Association,has an Operational Agreement(FORM:HOA)been attached? ❑Yes ❑No ❑N/A 4. Origin of wastewater: (check all that apply): ❑Residential Owned ®Retail(stores,centers,malls) ❑ Car Wash ❑Residential Leased /I Retail with food preparation/service ®Hotel and/or Motels ❑ School/preschool/day care ❑Medical/dental/veterinary facilities ❑ Swimming Pool/Clubhouse Food and drink facilities ❑Church ❑ Swimming Pool/Filter Backwash ®Businesses/offices/factories /1 Nursing Home ❑ Other(Explain in Attachment) 5. Nature of wastewater: 100%Domestic/Commercial %Commercial 0%Industrial(See 15A NCAC 02T.0103(20)) >Is there a Pretreatment Program in effect? ❑Yes LI No 6. Has a flow reduction been approved under 15A NCAC 02T.0114(f)? ❑Yes 0 No D If yes,provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(f)) Daily Design Flow a'b No.of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and(e)(2)for caveats to wastewater design flow rates(i.e.,minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.0114] shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 0 GPD(per 15A NCAC 02T.0114) Do not include future flows or previously permitted allocations If permitted flow is zero,indicate why: ®Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑Flow has already been allocated in Permit Number: ❑Rehabilitation or replacement of existing sewer with no new flow expected ❑Other(Explain): FORM:FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305&MDC(Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8 47 PVC > Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305&MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: SD East LS 2. Approximate Coordinates(Decimal Degrees):Latitude: 35.809° Longitude:-79.090° 3. Design flow of the pump station: 1.5 millions gallons per day(firm capacity) 4. Operational point(s)of the pump(s): 1100 gallons per minute at 215 feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material 12 13,830 DIP 14 16,400 DIP 6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ® Standby power source or pump with automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T.0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant(draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump,including travel timeframes,shall be provided in the case of a multiple station power outage. FORM:FTA 04-16 Page 3 of 5 IX. SETBACKS&SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(0): , 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f)&(g) ®Yes ❑No > 15A NCAC 02T.0305(f)contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 24 inches Water mains(vertical-water over sewer including in benched trenches) 18 inches Water mains(horizontal) 10 feet Reclaimed water lines(vertical-reclaimed over sewer) 18 inches Reclaimed water lines(horizontal-.reclaimed over sewer) 2 feet **Any private or public water supply source,including any wells,WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V),B,SA,ORW,HOW,or SB from normal high water(or tide elevation)and wetlands(see item IX.2) 50 feet **Any other stream,lake,impoundment,or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches > 15A NCAC 02T.0305(g)contains alternatives where separations in 02T.0305(f)cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage > If noncompliance with 02T.0305(f)or(g),see Section X of this application 2. Does the project comply with separation requirements for wetlands?(50 feet of separation) ®Yes ❑No ❑N/A > See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑Yes ❑No ®N/A > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑Yes ®No individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 &Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ®Yes ❑No Per 15A NCAC 021.0105(c)(6), directly related environmental permits or certification applications are being prepared,have been applied for,or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans,stormwater management plans,etc.). 6. Does this project include any sewer collection lines that are deemed"high-priority?" Per 15A NCAC 02T.0402,"high-priority sewer"means"any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑Yes ®No ❑N/A > If yes,include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permitee's individual System-Wide Collection permit. FORM:FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T,the Minimum Design Criteria for the Permitting of Pwnn Stations and Force Mains(latest version),and the Gravity Sewer Minimum Design Criteria(latest version)as applicable? ®Yes ❑No If No,complete and submit the Variance/Alternative Design Request application(VADC 10-14)and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: attest that this application for (Professional Engi eer's name from Application Item I11.1.) has been reviewed by me and is accurate,complete and consistent with the information supplied in the plans,specifications, engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers(latest version),and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains(latest version). Although other professionals may have developed certain portions of this submittal package,inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE— In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,representation,or certification in any application package shall be guilty of a Class 2 misdemeanor,which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation. ---‘""---4...r*i i-4.20,--- 4SO y _...„ North Carolina Professional Engineer's seal,signature,and date: �o .C goo .p® [L • So ' 1 ,.1'.awN.,y. ® ,= ©4 SSIQ,. eado SEAL = 18894 1 sow F t c ............ Cfro'p�7a$a�®�'} "c�R,Yr.:_u 3. Applicant's Certification per 15A NCAC 02T.0106(b): °g' I, Michael J.Myers, President attest that this application for (Signature Authority's name&title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included,this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non- discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE— In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,representation,or certification in any application package shall be guilty of a Class 2 misdemeanor,which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. Signature: 141 Date: 62102_11g FORM:FTA 04-16 Page 5 of5 CE GROUP W. 301 GLENWOOD AVENUE,SUITE 220 NC Dept of Environmental Qua]ity RALEIGH,NC 27603 Phone:(919)367-8790 E-Mail:mark@cegroupinc.com APR 2 5 2018 Raleigh Regional Office Project Summary: SD East Lift Station Modification WQ 0039608 issued Dec 8, 2017 The SD East Lift Station is a regional pump station designed to accommodate future development along 15-501 corridor for the Briar Chapel project. With this submission; zero flow is assigned to this lift station permit. Flow will be established as individual projects are submitted for permitting. The station has been re-sized to accommodate future development with a pumpimg rate of 1100 GPM. The proposed forcemain route has been changed to pump directly to the WWTP and not affect existing forcemains and other lift stations within the project. Attached are plans reflecting the location of existing constructed casings that span Pokeberry Creek wetlands and floodplain. We will be utilizing the existing casings at this crossing. No impacts to wetlands will occur associated with this construction. PROVIDING CIVIL/SITE&INFRASTRUCTURE CONSULTING SERVICES'SINCE 1998 • w 1 GEAIER/LNOTES: T ���� a\ 11TH ---:-..±-'--1':_'-'2.--'74.7„,>,9,.;,„,-. 04,14,,,•7 f / 1. CONTRACTOR SHALL NOTIFY-NORTH CAR j i OUNA ONE CALL' 1-800-832-4949)AT LEAST 48 HOURS PRIOR TO _ _ / \qi1 _..z. '^'ASFlig ! BEGINNING CONSTRUCTOR OR EXCAVATOR TO HAVE EXISTING MUTES LOCATED. CONTRACTOR TO CONTACT ANY L _ `�- / I I / ` / 71 // LOCAL UTUTES THAT PROVIDE THEIR OWN LOCATOR SERVICE INDEPENDENT OF"NORTH CAROLINA ONE CALL'. /<4 ! ` ' _ I� / 2 AU.EXISTING UNDERGROUND UTILITIES ARE APPROXIMATELY LOCATED. ACTUAL LOCATION AND DEPTH SHALL BE Q "`� .. �' (f _ BWNMRf CONFIRMED IN THE FIELD PRIOR TO CONSTRUCTOR. Q 7 BIER / rat, I i I -W EXTEND 8 SANITARYSERER WE C 11 { STING PROPER Y 3. BEFORE STARTING ANY CONSTRUCTION OF IMPROVEMENTS WHIN ANY N C D O.T STREET OR HIGHWAY RIGHT-OF-WAY, U .`� :/ 1*I: a MAIN TO TIE INTO GRABBY SEWER i 1 fi - 7D 1 MANHOLE IN FRONT OF PUMP SANITMY SEWER /11 CONTACT NCOOT DISTRICT OFFICE AND OBTAIN AU.PERMITS AND ENCROACHMENTS KEEP COPIES ON CONSTRUCTION -;0 IT WNGA STATION•A•(N.F.V.) PLRRd STATION•A• j) -- _ OFFICE 24 HOURS IN ADVANCE BEFORE PLACING CURB AND GUTTER AT(rr Y. T _ ,' / STE ALSO CONTACT N.C.D.O.T.DISTRICTaO� O . Lo MAIN(NF.V.)^ I. I I Ifi .a (PHASE 3) ,-, -_ 338-828-1421 • y Li O PERENNIALS I a T - / �A)Z U'3 I 1 1 _ BEAVER DAM --z !/ -_ / 4. THERE ARE WETLANDS WITHIN THIS SITE. IT IS THE OWNER'S RESPONSIBILITY TO OBTAIN AND PROVIDE PERMITS FOR W 1�1 y 1 1I LsT ) !t / �/� _ WETLANDS JURISDICTION AND DISTURBANCE PRIOR TO ANY GRADING ACTIVITY a. -......5,\ I :1 II / • /�/' % ��� 0.' �O I. }J I ' _ 5 CONSTRUCTION. DIMENSIONS AND GRADES SHOWN CR THE PLANS SHALL BE GELD VERIFIED BY THE CONTRACTOR PRIOR TO K�4 ^ y n _ •\•.,yy� `• I AV I' :�I a. % 1 // CONSTRUCTION TO ALLOWCONTRACTORFOR SHALL NOTIFY THE OWNER IF MY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH y DL A'I �3z'1 � ///./___ (A/' F 1' { j / FOR NECESSARY PLAN OR GRADING CHANGES. NO EXTRA COMPENSATOR SHALL BE PND TO W/C-1 N IL' 1s7L •\ • • 'mh--......,_,_,,_ VL F / ' - I I / THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF O �' °i 1 I i I I/ ' ,// / SUCH NOTIFlCATON HAS NOT BEEN GIVEN. I.:' (� N / \ \ ` I ( i I / \ PRUJMINARV 100 YR / / MEANS AS TO EXACT LOCATOR AND/OR ELEVATION.INFORMATION SHOWN IS BASED ON FL "26. 00 m -__ -- '\\ Apr 3 % /; FLOODPWN j/ / / 6. 'N PREVIOUS OESGNNDRAWINGS YMICH HAVE BEEN RELEASED FOR CONSTRUCTOR O O C • I/ ) 1 j / - /// ' 7. STREAM AND WETLAND LOCATIONS ARE BASED ON DEUREATONS PROVIDED BY SOIL AND ENVIRONMENTAL CONSULTANTS r q FOS•:O _� �'/ 1 � I II, /+ ; _ _ + / /) . -i J /////. / (11010 RAVEN RIDGE ROAD,RALEIGH,NORTH CARCLNA 27814,PHONE:919-848-5900.CONTACT:SEAN CLARK).• EI V 0.1 V x / ' 1 f: ci 1 ,-/ / ' / • / 6 EXISTING MFRASIRUCIURE AS SHOWN IS CURRENTLY UNDER CONSTROCTICRI AND SHALL BE FIELD VERIFIED BY 1. LI. 3lI >1 r' j �• / % gg / / CONTRACTOR.REFER TO THE FOLLOWING JCNN R.MCADMS CO.,INC.CONSTRUCTION PLANS.AND ALL SUBSEOUENT Z 'm / CV 4 W / / CONSTRUCTION BULLETINS FOR INFORMATION ON E%ISTNG INFRASTRUCTURE• �rII y O \ I ` F i// �F'f_.70 14,,, l ` _ / / V _ Y / / / - BRIAR CHAPEL-PHASE 3 CONSTRUCTION PLANS SEALED DECEMBER 4.2006. / BRIAR CHAPEL-PHASE 4 CONSTRUCTOR PLANS SEALED JANUARY 15.2007, ' /�.L' `/ _ �'L. / TE TO EXISTING / • / MBAR CHAPEL-PACKAGE•A•-PHASE 1-SPRAY IRRIGATION ER090N CONTROL PLANS,SEALED MAY 18,2007. I 4 \ ' J 12•IRRIGATION //// \IIT I`V _ / '- ( ) / 9. TRENCH FOR WATER IRRIGATION AND M FORCE RAMC SHALL BE LINED NTH A LL BE 10 A MINIMUM OF 6.OVER ? E _ 1__ I I MAIN NF.V. / T / THE PIPE TO CONTAIN THE BACKFILL MATERIAL SELECT BACKFILL MATERIAL SHALL BE USED UNLESS NAIVE EXCAVATED / /"/- - -� / //// //• / MATERIAL IS APPROVED BY THE GEOTECHNICAL ENGINEER. • SEA • //' 40 _ _- // / // SANITARY SEWER NOTES: _ e 15391 41 i Thy` `�^� `. , / 1. RECLAMATION IRRIGATIONMAINS HAV£BEEN DESIGNED BY CE CROUP.REFER TO PLANS TITIfD•BRIAR CHAPEL- %�l�1\ lu ,,? � • � --1 V W 1 ��, _ / / Tar CHATHAM ' REUSE SYSTEM.PACKAGE•A•,SEALED MARCH ti,2005.AND ALL SUBSEOUFNT ISSUE DATE$FOR INFORMATION. ''y�A4 1 C�71'STREAM ' RD J 0..4, 1 V k .1 - /n // -- 2 IRRIGATOR MAINS SHALL BE C900.CL 200 PVC PIPE,OR AS DIRECTED BY THE CE GROUP,(PURPLE PANTEC 522). "•"" 1 . I / ./ / ' i / . _ �----1 USE MECHANICAL JOINT FITTINGS FOR PORTON UNDER POKEBERRY CREEK. `Y 1� ,rJalS��t/% � i f / / /l 3. SANITARY SEWER FORCE MAIN SHALL BE C900 Cl..150 PVC PIPE.USE MECHANICAL JOINT FITTINGS FOR PORTION BEES 400" ; 1 "/P 1/ UNDER POKEBERRY CREEK. Anger�.L-' VI ( I/ 1 WATER NOTES: / ' / / / / //U 1. WATER MAIN TO BE INSTALLED AT A DEPTH WITH CH A MINIMUM COVER OF 38 INDIES,WITH MINIMUM 18 INCHES L • � _-- / // L _ .- / VERTICAL CLEARANCE OR 10 FEET HORIZONTAL CLEARANCE FROM SANITARY SEWER GRAVITY MANS AND/OR FORCE \ V +AW • /I j \ \ I Il / MAINS.AND OR IRRIGATION MAINS ` DOSING DIRT VL // ( / 1. ALL WATER MAINS WITHINCPRIVATE AND RIGHTS-OF-WAY TO BE OWNED,OPERATED AND MAINTAINED BY CHATHAM ,`\ ROAD °-__.......",_"// / //•/ -\ I / /1 / COUNTY,AND'MU_BE CONTAINED WITHIN A 20'WIDE PUBLIC WATER UNE EASEMENT CENTERED ON THE PROPOSED / // / WATER UNE. \ i ``\•\ '-',A-•••• '%/ L-j"1i `...- I 3. ALL WATER SYSTEM CONSTRUCTOR SHALL BE IN ACCORDANCE WM CHATHAM COUNTY STANDARDS AND Z ``\ /, v�� T I I I I SPECIFICATIONS O FLOODPLAIR BIETIr \ / / ___�\ ;/J I CG% 4 j, / \ - // 1 1 A PORTION OF THIS PROPERTY IS LOCATED W SPECIAL ROOD HAZARD AREA CG AS SHOWN ON FEMA F.I.R.M.MAP/ \ \ 4\ �- I 37109775004 AND 37109785005 WITH AN EFFECTIVE DATE OF FEBRUARY 2,2007.THERE IS ALSO A CONDITIONAL / \\ ✓ / 1 / V` I I LETTER OF MAP REVISION IN REVIEW BATH FEMA AS OF 4-9-2007 FOR POKEBERRY CREEK,CASE/07-04-31988. �// / /j \ rs T A \ :/ (I // / ? UTILITY LEGEND .j�'N \ ,// i /' / 1 _ it i / h ` ' 1 SEWER GLEAN-OUT a N ,`�\\ / �/ 1 '7.-.°,*.� .} FIRE HYDRANT ASSEMBLYORE ROW ORECTONO' •\ `` `•_/ / 100 FFM FLOOOPIAN / ��/ ! / / \ / // FIRE DEPARTMENT CONNECTION(FDC) > ARROWO/, ; J / / UNE BREAKSYMBOL 1A�U// •/ r r. � x "" ' / ! / O WA ER METERti STORMNTUTY/PORD EASEMEN S (�3 F`\ �' /' / /•// K { d h�'. ' / - ) /�. N WATER VALVE 4.0'SD PRIVAEMENTUTY EASEMENTz/ // FSf( /.. _/ ® VALVE IN MANHOLE WATERLINE {Ny'j55 FORCE-MAIN / /// � _ __._I / '-i /III •�•- l- ri METER&VAULT WATER SERVICE UNE4 w � / / J/: :-'sem i l j...-� � r i/ / �„ REDUCER unuTY SLEEVE cti I vOi c / /R _ •/I \...� / / / / PLUG SANITARY SEVER'b / /' / // / ! APPROXIMATE WATER LINE OF %/ / 100 FFM FURMAN -.-----. u /• / / �/I IX.BEAVER PONDS / f // . ,' �'• SEWER SERVICE LINE O � BLOW-OFF ASSEMBLY • j' )jJ1 i,, / / 41/ / ��, -FM-FM- SEWER FORCE MAN i /, / ///:// i' _- /i / j • SANITARY SEVER MANHOLE Cg / /, PROPOSED 12• \ j / % IRRIGATION MAN �A Tar CHATHAM ( e / / j' DDaRU PER US WE- ' / f/1 CONTYsmeAM 1 l % /� INDMDWL PERMIT z BUFFEB I; / �` J / j" - _ Q I 11 ✓ SOS •/ i / // / `\ 1 '11 ( _.'.' • � / / f //// , FUTURE L5'SETBACK(MIND a O 1' / / ! / / 7 I CONSTRUCTION r41/1 T.� ��f \ I i / / I 0'STOCKPILE a c900 Cl.150 SS FM ASIDE,z - �3 / % // AREA(MIN.) /_ wSPIoEHSTEEL• / / c ./...-" \ 1 !1 i I / / , \ 2 1 CLEARANCE B DC ON 12 D9W a zao O I '1 i l / // l RRIGWN MAIN U z 1 1/ , FM FM - 88 ,`\ 11 ill -// ,%' , � / / IPROPOSED RRIGATION AN 91d , � IIBF et-IX RR--IRR 688- .'7' 4 g t 3 a. S \ \\ I i,, ' �' / d / -1 FORa/FTBERR One NI-r AND e PVC SCH 40 ff 1, IS/ / / UE UE UE UE UE UE -' 1 111 \\� / -w W W W �w W W w- 118 U ' % / PROPOSED WALKWAY(B!OTHERS) -10'CLEARANCE(194.) 4•PVC SCM W ELECTRICAL CONDUIT FR i g �, ' \ \\LR : . / ----_-- 3b CLEARANCE IN DIP WATER WIN INSIDE 16•STEL s R \ \ \ \\` �\ / ! / / / INCASEMENT WITH SPIDER BLOCKING iL W FUTURE ` , .1 \ •\L . i 1 -2C HMA7E/PUBUC U 1 / EXTEND 55 FORCE-MAIN OUTSIDE OF %/ �� {><i$} CONSTRUCTION 00 YEAR ROODP AN,PWC AND SET - \ \\; / J / / / MARKER POLL lT1lJIY F/SEMENT 5'SLT80.CK(MIN.) V 1 \ ; i- I I ;f?y'1tlp ltt 111 I /' / (kW�] I ' I \ \\4 l'' / /.. II:111'1 I EXTENo ALL UTERI LINES AND CONDUITS To / TYPICu POKERERRY I1TI7 SF m UNDER M V Ib : \ \�` 7 i' TYF UTKmES SECTION / / i A MINIMUM LENGTH of 5 OUTSIDE of THECr') SFJ`TiiS S 100-YEAR FLOODPLAIN,BOTH SIDES.PLUG ...... / / I% f'- • (- ) AND SET MARKER POLES AT BOTH END$ g /i e'GTE VALVE w 1 _ _ / / '1 \ '/1 / J 1 o / /'" WITH MARKEl SS FORCE R POST / / / \ -- A- -„_ ' Y - VJ darn 4" - - - Q li ir -.-. _ ._3- - ,- ■ -- Jj - 6 ___ _•_••� rnwea 6a NEW-05002 \\\\\ / c- I _.�� - 7 T i / ' +: , a .�M:NEw9soo2 u2a.9 .\ / .}------ j= / ,- ; ��_ /- spew �` 6Wna6m m: / / RJD 112•GTE VALVE IN ! //, 20'PRAATE/PUBLIC / \ IIAl Rpi WITH i UTILITIES EASEMENT j / �i 12•GTE VALVE N / 2\11////A VVVT 1.:::,, m 1 O. • \ 40 TFLAF'(1RARY LAIRS OF / MARKER ST WfTH ,,\ /• /, I MARKER PCST MARKER POST / 1 \/ 1 1 1 D�"omouAL PERIBT ` / =� y CRY GRAPHIC SCALE xo. 2007-11-16 _L i BY ,00 • `,\ \ i t A. / / V1 1 inch 60 fl rim McADAMS FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION d