HomeMy WebLinkAbout20180705 Ver 1_Full Set May9_20180522MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Cover Sheet, Vicinity Map, & Sheet Index 1.0 SHEET INDEX SHEET DESCRIPTION 1.0 COVER SHEET, VICINITY MAP, AND SHEET INDEX EXISTING CONDITIONS DEMOLITION PLAN EROSION & SEDIMENT CONTROL PLAN EROSION & SEDIMENT CONTROL PLAN - DETAILS PRIMARY RISER & OUTLET REPAIR 1.1 NOTES, ABBREVIATIONS, AND LEGEND HEADCUT / ERODED CHANNEL REPAIR EMERGENCY SPILLWAY DESIGN DAM EMBANKMENT REPAIR DAM EMBANKMENT - CROSS SECTIONS 2.0-2.4 3.0 4.0 4.1 5.0 7.0 8.0 9.0 9.1-9.2 6.0 EXISTING CONCRETE SPILLWAY REPAIR DETAILS10.0 1.2 SITE LAYOUT ROADWAY SIGN FLOW VALVE PHONE PED. LIGHT POLE TREE LINE POWER POLE GW GUY WIRE FENCE AS NOTED GUARD RAIL EXISTING CONTOUR WITH ELEVATION EDGE OF PAVEMENT EDGE OF CONCRETE CONCRETE GUM TREE PINE TREE LP T PPCPCONTROL POINT BUILDING OUTLINE OAK TREE CEDAR TREE MISC. TREE WOOD FENCE RIP RAP BOUNDARY LINE BOUNDARY CORNER FOUND AS NOTED TEMPORARY CONSTRUCTION EASEMENT TEMPORARY SILT FENCE LIMITS OF DISTURBANCE TEMPORARY PROTECTION FENCE LEGEND PROPOSED CONTOUR WITH ELEVATION170 MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Notes, Abbreviations, & Legend 1.1 STANDARD SITE ABBREVIATIONS DEFINITION OF TERMS: CONTACT PHONE NUMBERS: BEFORE YOU DIG! CONTACT ONE-CALL CENTER 1-800-632-4949 OR 811 GW GW GW GW GW GW GW GW X T T TT LP LP LP LP LP LP PP PP PP PP PP PP PP PPBOUNDARY LINEAPPARENT BOUNDARY OVERLAPPP PP PP GW MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Site Layout 1.2 PPPP PP GW GW GW GW GW GW GW X T T TT LP LP LP LP LP LP PP PP PP PP GW TERRY SANFORD DRIVE MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Demolition Plan 3.0 X OUTLET STRUCTURE TOP TRASH RACK GRATE=168.30' TOP EXISTING WOOD BOARD=165.17' TOP OF CONCRETE=164.17' IE=155.55' (4)(60" RCP) BOTTOM=154.62' INSIDE DIMENSION 7' x14' INSIDE DIMENSION 7' x14' 60" RCP 60" RCP 60" RCP 60" RCP PRIMARY OUTLET STRUCTURE DETAIL SLIDE GATE DETAIL TRASH RACK DETAIL ANCHOR BOLTS DETAIL PRIMARY OUTLET ACB REPAIRA 5.0SECTION MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Primary Riser & Outlet Repair 5.0 NOTES: 1.DIVERT FLOW TO ONE SIDE OF THE TWO-CHAMBER RISER STRUCTURE TO REPLACE TWO OF THE GATES AND TRASH RACKS IN THE DRY. DIVERT FLOW TO OTHER SIDE OF STRUCTURE TO REPLACE REMAINING TWO GATES AND TRASH RACKS IN THE DRY. 2.BARREL PIPES SHALL BE INSPECTED WHILE FLOW IS DIVERTED FOR GATE REPLACEMENT. CONTRACTOR SHALL COORDINATE WITH ENGINEER TO ALLOW FOR SUCH INSPECTION. 3.ELEVATIONS OF THE GABIONS AND ARTICULATED CONCRETE BLOCK SHALL BE FIELD LOCATED TO BLEND THE NEW BLOCK WITH THE EXISTING BLOCK, WHERE ADJACENT TO BLOCK, AND EXISTING GROUND ELEVATION, WHERE ADJACENT NATURAL GROUND, WITH MINIMAL GRADING OUTSIDE OF PROPOSED STRUCTURES. EXISTING CONCRETE SPILLWAYSECTION D 6.0 9' x 1' x 9' MATTRESS 9' x 1' x 12' MATTRESS 9' x 1' x 12' MATTRESS 9' x 1' x 12' MATTRESS 3'x1.5'x3' 3 ' x 3 ' x 6 ' 3' x 3' x 9' 3'x1.5'x6' GABION (TYP) SECTION E 6.0 3'x1.5'x3' CONCRETE SPILLWAY REPAIR 6' x 1.5' x 3' 9' x 1' x 12' RENO MATTRESS CONCRETE SPILLWAY MATERIAL UNKNOWN 3' x 1.5' x 6' EXPANDED SECTION D/6.0 THROUGH GABION REPAIR GABION GABION 1.5'2'SPILLWAY GROUTING REPAIR DETAIL1 6.0 6' x 1.5' x 3' 9' x 1' x 12' RENO MATTRESS CONCRETE SPILLWAY 3' x 1.5' x 6' GABION GABION 1.5'VARIES ALTERNATIVE GABION REPAIR2 6.0 MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Existing Concrete Spillway Repair 6.0 TEMPORARY CONSTRUCTI ON EASE MENT SECTION A 7.0 STATION HC/EC 0+27.85 PROFILE - HEADCUT / ERODED CHANNEL SECTION B 7.0 STATION HC/EC 0+77.68 SECTION C 7.0 STATION HC/EC 1+08.97 MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Headcut / Eroded Channel Repair 7.0 PLAN: EMERGENCY SPILLWAY EMERGENCY SPILLWAY SECTION A 8.0 EMERGENCY SPILLWAY AND LAKE DRAIN SECTION B 8.0 EMERGENCY SPILLWAY DOWNSTREAM FACE C 8.0 EMERGENCY SPILLWAY DOWNSTREAM CHANNEL D 8.0 MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Emergency Spillway and Lake Drain 8.0 EMERGENCY SPILLWAY LAKE DRAIN DETAIL2 8.1 ACB TYPICAL CHANNEL SCHEMATIC1 8.1 2' MIN2' MIN 125' 3 1 3 1 1' MIN1' MIN LOW FLOW AREA AT LAKE DRAIN3 8.1 SECTION E 8.1 LAKE DRAIN PIPE NOT TO SCALE MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Emergency Spillway and Lake Drain 8.1 Pipe Inlet Strainer/Trash Guard Detail Pipe Outlet Varmint Guard Detail TYPICAL DAM CROSS SECTION MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Dam Embankment Repair 9.0 NOTES: 1.FINAL CREST ELEVATION SHALL BE 169.5 ACROSS THE ENTIRE LENGTH OF THE EMBANKMENT, WITH THE EXCEPTION OF THE PROPOSED EMERGENCY SPILLWAY AND AREAS WHERE EXISTING ELEVATION IS GREATER THAN 169.5. 2.RAISING THE CREST ELEVATION WILL EXTEND THE SLOPED FACE ON THE DOWNSTREAM SIDE OF THE EMBANKMENT FROM STATION 0+00 TO 36+00 AND ON THE UPSTREAM SIDE OF THE EMBANKMENT FROM STATION 36+00 TO 60+80. SEE CROSS SECTIONS ON SHEETS 9.1 AND 9.2. 3.EXTENDED SLOPES ON THE DOWNSTREAM FACE SHALL BE CONSTRUCTED AT 3:1 SLOPE. EXTENDED SLOPES ON THE UPSTREAM FACE SHALL BE CONSTRUCTED AT 3:1 SLOPE ABOVE THE NORMAL POOL ELEVATION OF 165 AND AT 2:1 SLOPE BELOW ELEVATION 165. 4.FILL MATERIAL FOR THE EMBANKMENT REPAIR WILL BE EXCAVATED FROM BORROW AREAS ON SITE. BORROW AREAS ARE SHOWN ON THE SITE LAYOUT ON SHEET 1.2. 5.FILL MATERIAL USED TO RAISE THE CREST OF THE DAM SHALL CONTAIN 20% OR MORE FINES PASSING THE #200 SIEVE WITH SOME PLASTICITY. CLEANER SANDS AS WELL AS CLAYEY SANDS CAN BE USED ON THE EMBANKMENT FACE. CONTRACTOR SHALL COORDINATE WITH THE GEOTECHNICAL ENGINEER FOR FILL MATERIAL SELECTION. 6.ALL NEW FILL PLACED ON THE EMBANKMENT SHALL BE COMPACETED TO NOT LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY AT MOISTURE CONTENTS OF OPTIMUM MOISTURE TO 3% WET OF OPTIMUM. GW PPPPPPPPPPPPMAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Dam Embankment Repair - Cross Sections 9.1 GW GW GW GW GWT TLPLPLPPPPPPPPPPPGW MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Dam Embankment Repair - Cross Sections 9.2 PUBLIC STREET EXISTING GROUND 50' MIN.18' MIN.6" MIN.TYPE II FILTER FABRIC UNDER 2"-3" COURSE AGGREGATE 50' MIN.PUBLIC STREETNOTES: 1.A STABILIZED ENTRANCE PAD OF 2"-3" COURSE AGGREGATE SHALL BE LOCATED WHERE TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET OR EXISTING GRAVEL/PAVED SURFACE. 2.FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHALL BE USED AS A BASE FOR THE CONSTRUCTION ENTRANCE. 3.THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4.ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. 5.WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHALL BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN SEE STD. NO. 30.11B. 6.NCDOT MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY (STD. 10.24 & 10.25) TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS ON A THOROUGHFARE. CONSTRUCTION ENTRANCE FILL SL O P E FLOW TEMPORARY SILT FENCE NOTES: 1.FILTER FABRIC FENCE SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. 2.WOVEN FILTER FABRIC TO BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 3.STEEL POSTS SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF-FASTENER ANGLE STEEL TYPE. 4.TURN SILT FENCE UP SLOPE AT ENDS. 5.DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 6.SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 7.DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. 8.INSTALL POSTS WITH THE NIPPLES FACING AWAY FROM THE SILT FENCE. 9.ATTACH THE FABRIC TO EACH POST WITH THREE TIES WITH THE TOP TIE WITHIN 8” OF THE TOP OF THE FABRIC. 10.WRAP APPROXIMATELY 6 INCHES OF FABRIC AROUND THE END POSTS AND SECURE WITH 3 TIES. 11.CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. TEMPORARY SILT FENCE MAINTENANCE NOTES: 1.INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2.SHOULD THE FABRIC OF THE SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3.REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4.REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. WOVEN FILTER FABRIC STEEL POST 8' MAX 2'-0"STEEL POST WOVEN FILTER FABRIC 30" MIN24" FILTER FABRICANCHOR SKIRT 8" MINIMUM TEMPORARY SILT FENCE 4'-10" FINISHED GRADE WIRE OR ZIP TIES TO SECURE SAFETY FENCE TO POST STAKES: 66" T-POST DRIVEN 18" BELOW GRADE 48" HIGH DENSITY ORANGE POLYETHYLENE SAFETY FENCE STAKE SPACING 12' ON CENTER TEMPORARY PROTECTION FENCE NOTES: 1.HAVE ALL NECESSARY MATERIALS AND EQUIPMENT ON-SITE BEFORE WORK BEGINS. 2.CLEARING IN THE WETLAND IS PROHIBITED. 3.INSTALL RAMP ACCESS OUTSIDE OF WETLAND AREA. LINE ACCESS RAMP AREA WITH NON-WOVEN FILTER FABRIC AND CONSTRUCT RAMP WITH CLASS B RIP RAP. 4.INSTALL MUD MATS IN LOCATIONS SPECIFIED IN THE PLAN VIEW. 5.MAINTAIN CROSSING SO THAT RUNOFF FROM THE CONSTRUCTION ROAD DOES NOT ENTER WETLAND. 6.THE WOOD MAT SHALL BE OF SUFFICIENT SIZE AND WIDTH TO SUPPORT THE LARGEST VEHICLE CROSSING THE WETLAND. 7.CONTRACTOR SHALL DETERMINE AN APPROPRIATE RAMP ANGLE ACCORDING TO EQUIPMENT UTILIZED, RECOMMENDED MAXIMUM 5:1 SLOPE. 8.AFTER CONSTRUCTION IS COMPLETE, REMOVE MUDMATS, ACCESS RAMPS AND SEED WETLAND ACCORDING TO THE PLANTING PLAN. TEMPORARY WETLAND CROSSING - MUDMAT 6" MIN WIDTH FOR 2" TREES OR SMALLER DEAD TREES AND SCRUB OR UNDER GROWTH SHALL BE CUT FLUSH WITH ADJACENT GRADE. NO GRUBBING ALLOWED UNDER DRIP LINE. 2x4" STANDARDS + 1x4" RAILS OR ORANGE SAFETY FENCING MAY BE USED. SEE DETAIL 3/10.0. PLAN VIEW OF ROOT ZONE FOR PRUNING SEE NATIONAL ARBORIST ASSOCIATION SPECS. TREE LIMB REMOVAL 1. REMOVE ALL BARRIERS UPON COMPLETION OF PROJECT. 2. SEE PLANS FOR LOCATION OF ALL TREE PROTECTION FENCES. NOTES TREE PRUNING 3'-0" 3'-0" 6" BARK MULCH, PLACE BARK MULCH AT AREAS NOT PROTECTED BY BARRIER TREE PROTECTION INSTALLATION 1.LIFTING STRAPS SHALL BE PLACED UNDER THE FILTER BAG TO FACILITATE REMOVAL AFTER USE. 2.PLACE FILTER BAG ON A LEVEL STABILIZED AREA OVER GRAVEL. 3.INSERT DISCHARGE HOSE FROM PUMP INTO FILTER BAG A MINIMUM OF SIX INCHES (6") AND TIGHTLY SECURE WITH STRAP TO PREVENT WATER FROM FLOWING OUT OF THE BAG WITHOUT BEING FILTERED. 4.REPLACE THE UNIT WHEN ONE HALF (1 2) FULL OF SEDIMENT OR WHEN SEDIMENT HAS REDUCED THE FLOW RATE OF THE PUMP DISCHARGE TO AN IMPRACTICAL RATE. 5.MATERIAL REMOVED FROM SILT BAGS CAN BE SPREAD ON SITE AS LANDSCAPE MATERIAL AS LONG AS IT HAS BEEN ADEQUATELY DEWATERED SUCH THAT IT WILL NOT MIGRATE DOWNSLOPE WHEN PLACED. SILT BAG MATERIAL SHALL NOT BE USED AS BACKFILL OR PLACED WHERE STRUCTURAL MATERIAL IS REQUIRED. DEWATERING WITH FILTER BAG DETAIL MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Details 10.0 ARMORTEC'TQUKQP%QPVTQN5QNWVKQPU #%106'%*%1/2#0; %'064'21+06'&457+6' 9'56%*'56'41*+1 2*  Ä(#:  Ä ARTICULATED BLOCK - OPEN CELL MAT ARTICULATED BLOCK - STANDARD DIMENSIONS ARMORTEC'TQUKQP%QPVTQN5QNWVKQPU #%106'%*%1/2#0; %'064'21+06'&457+6' 9'56%*'56'41*+1 2*  Ä(#:  Ä MAY 3, 2018 Lumbee Tribe of NC - Cultural Center Lake Dam Repairs PO BOX 2294 LIC # C1842 KERNERSVILLE, NC 27284 OFFICE: (336) 996-9974 jewellengineering.pro SHEET NO. 17-233-014 PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION Details 10.1 BEDDING FOR ACB DETAIL