Loading...
HomeMy WebLinkAbout20180670 Ver 1_Riparian Buffer Authorization_20180515Bobbitt Design -Build, Inc 600 Germantown Road Raleigh North Carolina 27607 2 0 l 8 G 6 7 0 Letter of Transmittal (919) 851-1980 Date: 15 -May -18 Job Number: 1953-0072 Fax (919) 851-1982 Reason: Triangle Pond Mangement bobbitt.com 3717 Overlook Road, Raleigh 27616 Buffer Authorization To: INC DWR-Buffer Permitting Attention: I Karen Higgins 512 N. Salisbury Street Raleigh, NC 27604 We are sending you the following items: Shop drawings x Plans Copy of letter Samples Prints Specifications Change order Copies Date No. Description 3 Buffer Authorization Form 3 USGS Maps 3 Soil Maps 3 Aerial Images 3 Sand Filter Supplement Form 3 LS-VFS Supplement Form 3 Operation and Maintenance Agreement 3 Peak Flow Modeling 3 Nutrient Loading Calculations 2 Full Size Plans 1 11x17 Size Plans Remarks: These are transmitted: FOR BIDS DUE (Date) x For approval x For your use As requested For review & comment Approved as submitted Returned for corrections Resubmit_ copies for approval Submit ' copies for approval Return corrected prints r ICaAQ ball 11 Yuu I Iavu ally 4uvauul 1J Thanks Copy to: File From: Blair Pittman bpittman(cD-bobbitt.com DWR State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02B.0233 (8)(b), .0243 (8)(b), .0250 (11)(b), .0259 (8)(b), .0267 (11)(c),.0607 (e)(2) - Buffer Authorization FORM: BA 10-2013 Riparian Buffer Authorization Form A. Applicant Information 1. Project Information 1a. Name of project: Triangle Pond Management 1b. County: Wake 1c. Nearest municipality: Raleigh 1d. Subdivision name: Not Applicable 1e. Is the project located in any of North Carolina's twenty coastal counties? If yes, answer 1f below. ❑ Yes ® No 1f. Is the project located within a NC Division of Coastal Management Area of Environmental Concern (AEC)? ❑ Yes ® No 2. Owner Information 2a. Name on Recorded Deed: SAL Real Estate LLC 2b. Deed Book and Page No. BKO15779 PGO1893 2c. Map Book and Page No. (include a copy of the recorded map that indicates when the lot was created): BM2017 PG02543 2d. Responsible Party for Corporations): Samuel L Williams 2e. Street address: 100 Oak Grove Church Road 2f. City, state, zip: Youngsville, NC 27596-7560 2g. Telephone no.: (919) 398-3221 2h. Fax no.: 2i. Email address: office@trianglepond.com 3. Applicant Information (if different from owner) 3a. Applicant is: ® Agent ❑ Other, specify: 3b. Name: Blair Pittman 3c. Business name if applicable): Bobbitt Design Build, Inc. 3d. Street address: 600 Germantown Road 3e. City, state, zip: Raleigh, NC 27607 3f. Telephone no.: (919) 851-1980 3g. Fax no.: (919) 851-1982 3h. Email address: bpittman@bobbitt.com 4. Agent/Consultant Information (if applicable) 4a. Name: 4b. Business name if applicable): 4c. Street address: 4d. City, state, zip: 4e. Telephone no.: 4f. Fax no.: 4g. Email address: FORM: BA 10-2013 Page 1 of 4 B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): 1727-55-3505 1b. Site coordinates (in decimal degrees): Latitude: 35.8800 Longitude: -78.5769 1 c. Property size: 0.72 acres 2. Surface Waters 2a. Name of nearest body of water to proposed project: Gresham Lake (Perry Creek) 2b. Water Quality Classification of nearest receiving water: B, NSW 2c. River basin: Neuse 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The site is currently vacant with poor herbaceous growth. The general land use in the vicinity of the project is industrial. 3b. Attach an 8'/ x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site 3c. Attach an 8'/ x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site 3d. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 0 LF 3e. Explain the purpose of the proposed project: New flex -use building and associated truck yard, parking, and utilities. 3f. Describe the overall project in detail, including the type of equipment to be used: This project will construct a 5,000 sf flex -use building, truck yard, and parking lot. The property is located between two similar light industrial uses on a currently vacant lot. The site is constrained by an existing City of Raleigh Sanitary Sewer Easement on the south side of the property. Standard construction equipment will be used with the exception of a crane for underground sand filter installation. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property/ project(including all priorphases) in thepast? ❑ Yes ® No ❑ Unknown Comments: 4b. If yes, who delineated the jurisdictional areas? Name (if known): Agency/ Consultant Company: Other: 4c. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. 5. Project History 5a. Have permits or certifications been requested or obtained for this project(including all priorphases) in thepast? El Yes ® No ❑ Unknown 5b. If yes, explain and detail according to "help file" instructions. 6. Future Project Plans 6a. Is this a phased project? ❑ Yes ® No 6b. If yes, explain. FORM: BA 10-2013 Page 2 of 4 C. Proposed Impacts Inventory 1. Buffer Impacts 1a. Project is in which protected basin? ® Neuse ❑ Tar -Pamlico ❑ Catawba ❑ Randleman ❑ Jordan ❑ Goose Creek 1b. Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. Buffer impact number — Permanent (P) or Temporary T Reason for impact Type of impact (exempt, allowable, allowable w/ mitigation) Stream name Buffer mitigation required? Zone 1 impact (sq ft) Zone 2 impact (sq ft) B1 ® P ❑ T Stormwater Outfall w/ SCM Allowable Gresham Lake (Perry Creek) El Yes ®No 0 455 sf B2 ❑P n El Yes ❑No B3 ❑ P ❑ T ❑ Yes ❑ No B4 ❑ P ❑ T ❑ Yes ❑ No B5 ❑ P ❑ T ❑ Yes ❑ No B6 P ❑ T ❑ Yes ❑ No Total buffer impacts 455 sf 1 c. Comments: A sand filter is proposed upstream of the stormwater outfall to control nitrogen and attenuate flow D. Impact Justification and Mitigation 1. Avoidance and Minimization 1 a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. Based on the existing topography on site, there is no feasible means to collect/treat Stormwater and discharge without impacting the stream buffer. The impact was minimized by using an underground sand filter and also by using a minimal slope (0.5%) on the outlet pipe leaving the underground sand filter. This isolates the impact to the buffer to zone 2 only. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Silt fence will be installed downslope from disturbance. Site access from higher ground. 2. Buffer Mitigation 2a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? ❑ Yes ® No 2b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation and calculate the amount of mitigation required in the table below. Zone Reason for impact Total impact Multiplier Required mitigation (square feet (square feet Zone 1 3 (2 for Catawba) Zone 2 1.5 Total buffer mitigation required: 2c. If buffer mitigation is required, is payment to a mitigation bank or NC DMS ❑ Yes ❑ No proposed? 2d. If yes, attach the acceptance letter from the mitigation bank or NC DMS. 2e. If no, then discuss what type of mitigation is proposed. 2f. Comments: FORM: BA 10-2013 Page 3 of 4 E. Diffuse Flow Plan All buffer impacts and high ground impacts require diffuse flow or other form of ® Diffuse flow stormwater treatment. Include a plan that fully documents how diffuse flow will be ❑ Other BMP maintained. If a Level Spreader is proposed, attach a Level Spreader Supplement Form. 1 b. If you answered "yes" to the above, does the project require preparation of an If due to site constraints, a BMP other than a level spreader is proposed, please provide a environmental document pursuant to the requirements of the National or State (North plan for stormwater treatment as outlined in Chapter 8 of the NC Stormwater BMP Carolina) Environmental Policy Act NEPA/SEPA ? Manual and attach a BMP Supplement Form. 1 c. If you answered "yes" to the above, has the document been finalized by the State F. Supplementary Information 1. Environmental Documentation 1 a. Does the project involve an expenditure of public (federal/state/local) funds or the ❑ Yes ® No use of public federal/state land? 1 b. If you answered "yes" to the above, does the project require preparation of an ❑ Yes ❑ No environmental document pursuant to the requirements of the National or State (North Carolina) Environmental Policy Act NEPA/SEPA ? 1 c. If you answered "yes" to the above, has the document been finalized by the State ❑ Yes ❑ No Clearing House? (If so, attach a copy of the NEPA or SEPA final approval letter.) Comments: 2. Violations 2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated ❑ Yes ® No Wetland Rules (15A NCAC 02H .1300), DWR Surface Water or Wetland Standards, or Riparian Buffer Rules 15A NCAC 02B .0200)? 2b. Is this an after -the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): f, TT -M I iw✓ !0411 b If I Applicant/Agent's Printed Name Applicant/Agent's Signature Date (Agent's signature is valid only if an authorization letter from the applicant is provided.) Send 3 complete sets of this form and accompanying documents to the following: For government transportation projects sent by First Class Mail via the US Postal Service: NC DWR, Transportation Permitting Unit 1617 Mail Service Center Raleigh, NC 27699 - 1617 For all other projects sent by First Class Mail via the US Postal Service For government transportation projects sent by delivery service (UPS, FedEx, etc.): OR NC DWR, Transportation Permitting Unit 512 N. Salisbury Street Raleigh, NC 27604 For all other projects sent by delivery service (UPS, FedEx, etc.): Karen Higgins Karen Higgins NCDWR — 401 & Buffer Permitting Branch OR NCDWR — 401 & Buffer Permitting Branch 1617 Mail Service Center 512 N. Salisbury Street Raleigh, NC 27699 - 1617 Raleigh, NC 27604 FORM: BA 10-2013 Page 4 of 4 W DR ent 2014 2016 2016 2014 2008 -2016 2014 e OAK gORO DR PP FALLS i<1JaOAi, _ a, F4RM/NGTON �'� ae +� 9' 16" 165 MILS N V 26" 25 MILS UTM GRID AND 2016 MAGNETIC NORTH DECLINATION AT CENTER OF SHEET U.S. National Grid 100,000•m Square D Qv GrW ZoneDesignation 175 35' -m+. -W- -aY- -ay 719 720 ': SCALE 1:24 000 1 0.5 0 KILOMETERS 1 1000 500 0 METERS 1000 1 0.5 0 MILES 1000 0 1000 2000 3000 4000 5000 6000 7000 FEET CONTOUR INTERVAL 10 FEET NORTH AMERICAN VERTICAL DATUM OF 1988 This map was produced to conform with the National Geospatial Program US Topo Product Standard, 2011. A metadata file associated with this product is draft version 0.6.19 30 CeB2 (loins sheer 2)) W, Y ApC2 Ap82 WAKE COUNTY, NORTH CA N HeC2 �? r CrC,EnC r �T CeB2 .+ s@ vs (, Wnf J, o h r l 1' . � B; ;t' 6 WME 1 / Ap82 ApB2 MW! W APB EnD2 d.. Ce( ✓ r ° 1 AIik2 '7 Cerz y 3 1 � ` 4na ty o :'t -"eD` AfA f ' Ly,2 1 POR 62 Ap0 2 �D�: • .. Crn ' ♦ APB2 Loi3 y_. ,i' i � 3 r 4.1 CeD APi.'. �. Ar:e n IN CsB2 ?! 1rAoC,2,`. t AIA, ApB2 t 'r ,►YOB bPB CeC LOC L08 AP87� r` En82 AD B y AfA o APB2 9� s `r •. / CeC2 / / ; E APB2 , AEtC •, pC2 w.. ApBz R S i Ma SI%'� CeB? a A C-.,1'{jAfA01 Wy ' C14 Ofty a' , em CeB2 APr A _ y En82 • HeD N P w Ma w •.6 at VYkE ApD N w H APC • _.\ a 'S / Ln Au ) Ap82 ApC2 o A HeB2 Ln!Hee Lv �, ake Gresham ` �u f 2 S�ti Dv8 I AP82^, Wo Gu C (n m / ) t 1MkE 74tgrr'`�,,,,�Api:2 \ r GCn Y l Cvu j\ if t u _ Wo Go f Ny 1 �Y LO R { V 1 AaB2 ; \ ! N j IcE APAP82y APC' r g C ApC2 sE;* O * APH� e ; i LoDLa a •� . WMC2 WmC CeC7 2. Cs62 -- ..s a V�kE !°+ LOCAPBZ, o d C Cef3z , Cre22 ~ 1 t.eC LobR m ApBB2 {� Cn I AOC2 1 N{. APG WkE N APB2 ! Wm �P wMCi o \ Lot Wm62 v AP02 F , t\ Lo mB2 eCz Cn 1 m62 AD82 m / AP \ e8 LOC k4flC AfA eB2 Ap ! APC p WMC2 t i i WEE LOS WMB WmD2 o pC2 k LoD G Mal Y LOU LoC ,2 a Lo8 ) wMC LOC WkE '.. � WkE � . w .P APB2 LoC Lo1) A APC2 LOC Gu X00 Wmw Lac / m L*C (loins sheet 40) kE LOU WkE UNDERGROUND SAND FILTER LEVEL SPREADER 0 30 60 120 0+1 1"=60' 8.5X11 4 TRIANGLE POND MANAGEMENT 3717 OVERLOOK ROAD RALEIGH, NORTH CAROLINA BOBBITT DESIGN BUILD. INC. V1 BOBerrr �WRI`�"N°�, ".w_ F1L 101 W t-1Wt IW EdBO0BaBITT COM w . 4 COPYRIGHT C 2013 BOBB(TT OE810N BUILD, INC. ALL RMM RESERVED. Permit Number: (to be provided by DWQ) p�'�� h NCDEHR ° STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM SAND FILTER SUPPLEMENT This form must be filled out on line, printed and submitted with all of the required information. Make sure to also fill out and submit the Required Items Checklist (Section 111) and the I&M Agreement (Section IV) I. PROJECT INFORMATION Project name Triangle Pond Management Contact name Blair Pittman Phone number Date Drainage area number (919) 851-1980 May 15, 2018 30202010704 II. DESIGN INFORMATION 1.00 Site Characteristics 1 -yr, 24 -hr intensity Drainage area (AD) 17,424.00 ft2 OK Impervious area 16,030.00 ft % Impervious (IA) 92.0% % Design rainfall depth (RD) 1.00 in Peak Flow Calculations 1 -yr, 24 -hr runoff depth 1.00 in 1 -yr, 24 -hr intensity 4.48 in/hr Pre -development 1 -yr, 24 -hr runoff 0.71 ft3/sec Post -development 1 -yr, 24 -hr runoff 0.01 ft3/sec Pre/Post 1 -yr, 24 -hr peak control -0.70 ft3/sec Storage Volume Design volume (WQV) 1,278.00 ft3 Adjusted water quality volume (WQVAd) 958.50 ft3 Volume contained in the sedimentation basin and on top of the sand filter 1,000.00 ft3 Top of sand filter/grate elevation 253.5 ft amsl Weir elevation (between chambers) 253.5 ft amsl Maximum head on the sedimentation basin and sand filter (hm.Fifter) 5.50 ft Average head on the sedimentation basin and sand filter (hA) 2.75 ft Runoff Coefficient (Rv) 0.88 (unitless) Type of Sand Filter Open sand filter? N Y or N SHWT elevation ft amsl Bottom of the sand filter elevation ft amsl Clearance (dSHWT) Closed/pre-cast sand filter? Y Y or N SHWT elevation NA ft amsl Bottom of the sand filter elevation 251.50 ft amsl Clearance (dSHWT) >1 ft If this is a closed, underground closed sand filter: The clearance between the surface of the sand filter and the bottom of the roof of the underground 1.00 ft structure (dsp e) *0 OK OK Form SW401-Sand Filter-Rev.5 2009Sept17 Parts I and II. Project Design Summary, Page 1 of 2 Sedimentation Basin Surface area of sedimentation basin (As) Sedimentation basin/chamber depth Sand Filter Surface area of sand filter (Ar) Top of sand media filter bed elevation Bottom of sand media filter bed/drain elevation Depth of the sand media filter bed (dr) Coefficient of permeability for the sand filter (k) Outlet diameter Outlet discharge/flowrate Time to drain the sand filter (t) Time to drain the sand filter (t) Additional Information Does volume in excess of the design volume bypass the sand filter? Is an off-line flow -splitting device used? If draining to SA waters: Does volume in excess of the design volume flow evenly distributed through a vegetated filter? What is the length of the vegetated filter? Does the design use a level spreader to evenly distribute flow? Is the BMP located at least 30ft from surface waters (50ft if SA waters)? If not a closed bottom, is BMP located at least 1 00f from water supply wells? Are the vegetated side slopes equal to or less than 3:1 Is the BMP located in a recorded drainage easement with a recorded access easement to a public Right of Way (ROW)? What is the width of the sedimentation chamber/forebay (Ww)? What is the depth of sand over the outlet pipe (dpipe)? 100.00 ft, 5.50 ft 100.00 ft 253.50 It amsl 251.50 ft amsl 2.00 It 4.00 (ft/day) 10.00 in 0.01 ft3/sec 30.50 hours 1.27 days Permit Number: (to be provided by DWQ) Ur\. IVICCLJ 11111 11111U111, UUL IIIay IICCU LU UC IIILJCGJCU LU IIR.ICGJC DUIIaL.0 aICa. 1 111z VVIII a1DU MUCQJC UIC ......1..-1- _L:I:L. 1.. ...... {..:.. 1L_ .J:....1..J .....{... _ -1:4. OK. Submit drainage calculations. Y Y or N OK Y YorN OK YorN Y YorN OK 10.00 ft OK 1.50 It OK Form SW401-Sand Filter-Rev.5 2009Sept17 Parts I and 11. Project Design Summary, Page 2 of 2 NA ft Y YorN OK Y YorN OK Y YorN OK Y YorN OK Y YorN OK 10.00 ft OK 1.50 It OK Form SW401-Sand Filter-Rev.5 2009Sept17 Parts I and 11. Project Design Summary, Page 2 of 2 If Stormwater Enters the LS-VFS from a BMP o`'o� wAT Fq�c HCDENR > y Peak discharge from the BMP during the design storm STORMWATER MANAGEMENT PERMIT APPLICATION FORM Peak discharge from the BMP during the 10 -year storm 401 CERTIFICATION APPLICATION FORM LEVEL SPREADER - VEGETATED FILTER STRIP (LS-VFS) SUPPLEMENT This form must be completely filled out, printed, initialed, and submitted. I. PROJECT INFORMATION 1.12 cfs Project name Triangle Pond Management Contact name Blair Pittman Phone number (919) 851-1980 Date May 10, 2018 Drainage area number 30202010704 II. DESIGN INFORMATION The purpose of the LS-VFS Buffer Rule: Diffuse Flow Stormwater enters LS-VFS from A BMP Type of VFS Other: Explained below Explanation of any "Other" responses above LS discharges into Zone 1 of a Neuse stream buffer. Existing zone 1 slope is >5% If Stormwater Enters the LS-VFS from the Drainage Area Drainage area ftp Do not complete this section of the form Impervious surface area fe Do not complete this section of the form Percent impervious % Do not complete this section of the form. Rational C coefficient Do not complete this section of the form. Peak flow from the 1 in/hr storm cis Do not complete this section of the form Time of concentration min Do not complete this section of the form Rainfall intensity, 10 -yr storm in/hr Do not complete this section of the form Peak flow from the 10 -yr storm cis Do not complete this section of the form Design storm Pick one: Maximum amount of flow directed to the LS-VFS cis Do not complete this section of the form Is a flow bypass system going to be used? (Y or N) Do not complete this section of the form Explanation of any "Other" responses above If Stormwater Enters the LS-VFS from a BMP Type of BMP Other: Explained below Peak discharge from the BMP during the design storm 0.007 cis Peak discharge from the BMP during the 10 -year storm 0.008 cis Maximum capacity of a 100 -foot long LS-VFS cfs Peak flow directed to the LS-VFS 1.12 cfs Is a flow bypass system going to be used? N (Y or N) Explanation of any "Other" responses above Stormwater enters from an underground sand filter Form SW401 - LS-VFS - 29June2012 - Rev. 10 page 1 of 3 LS-VFS Design Forebay surface area Depth of forebay at stormwater entry point Depth of forebay at stormwater exit point Feet of level lip needed per cls Computed minimum length of the level lip needed Length of level lip provided Width of VFS Elevation at downslope base of level lip Elevation at the end of the VFS that is farthest from the LS Slope (from level lip to the end of the VFS) Are any draws present in the VFS? Is there a collector swale at the end of the VFS? Bypass System Design (if applicable) Is a bypass system provided? Is there an engineered flow splitting device? Dimensions of the channel (see diagram below): M B W y (flow depth for 10 -year storm) freeboard (during the 10 -year storm) Peak velocity in the channel during the 10 -yr storm Channel lining material Does the bypass discharge through a wetland? Does the channel enter the stream at an angle? Explanation of any "Other' responses above 38 sq ft No forebay is required 13 in 6 in Depth is appropriate fUcfs ft 10 ft Level spreader is too short to handle the flow 30 ft 250.50 fmsl 243.00 fmsl 25.00 % VFS is too steep N (Y or N) OK N (Y or N) N (Y or N) N (Y or N) NA ft NA ft NA ft NA ft NA ft NA fUsec Pick one: W N (Y or N) Y (Y or N) B Form SW401 - LS-VFS - 29June2012 - Rev. 10 page 2 of 3 III. REQUIRED ITEMS CHECKLIST EDIT Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate the following design requirements have been met. If the applicant has designated an agent, the agent may initial below. If a requirement has not been met, attach justification. Requried Item: 1. Plans (1" - 50' or larger) of the entire site showing: - Design at ultimate build -out, Off-site drainage (if applicable), Delineated drainage basins (include Rational C coefficient per basin), Forebay (if applicable), High flow bypass system, Maintenance access, Proposed drainage easement and public right of way (ROW), and Boundaries of drainage easement. 2. Plan details (1" = 30' or larger) for the level spreader showing: - Forebay (if applicable), High flow bypass system, One foot topo lines between the level lip and top of stream bank, Proposed drainage easement, and Design at ultimate build -out. 3. Section view of the level spreader (1" = 20' or larger) showing: - Underdrain system (if applicable), Level lip, Upslope channel, and Downslope filter fabric. 4. Plan details of the flow splitting device and supporting calculations (if applicable). 5. A construction sequence that shows how the level spreader will be protected from sediment until the entire drainage area is stabilized. 6. If a non -engineered VFS is being used, then provide a photograph of the VFS showing that no draws are present. 7. The supporting calculations. 8. A copy of the signed and notarized operation and maintenance (08M) agreement. Initials Page or plan sheet number and any notes: BA2.0 BA2.0 I BA3.0 1.0 Form SW401 - LS-VFS - 29June2012 - Rev. 10 page 3 of 3 Operation & Maintenance Agreement Project Name: Project Location: on Triangle Pond Management Raleigh, NC nce a loa in a known set Any deficient BMP elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the BMP(s). The BMP(s) on this project include (check all that apply & cc Bioretention Cell Quantity: Dry Detention Basin Grassed Swale Green Roof Infiltration Basin Infiltration Trench Level SpreaderNFS Permeable Pavement Proprietary System Rainwater Harvesting Sand Filter Stormwater Wetland Wet Detention Basin Disconnected Impervious Area User Defined BMP Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Present: Present: ing O&M tables wil Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each BMP above, and attached O&M tables. I agree to notify NCDENR of any problems with the system or prior to any changes to the system or responsible party. * Responsible Party: Title & Organization: Street address: City, state, zip: Phone number(s): Email: Signature: County of personally appeared before me this , a Notary Public for the State of , do hearby certify that day of acknowledge the due execution of the Operations and Maintenance Agreement. Witness my hand and official seal, Seal ;TORM-EZ /ersion 1.4 My commission expires O&M Manual Date: and 5/15/2018 Page 1 of 1 Important maintenance procedures: Immediately after the filter strip is established, any newly planted vegetation will be watered twice weekly if needed until the plants become established (commonly six weeks). - Once a year, the filter strip will be reseeded to maintain a dense growth of vegetation - Stable groundcover will be maintained in the drainage area to reduce the sediment load to the vegetation. Two to three times a year, grass filter strips will be mowed and the clippings harvested to promote the growth of thick vegetation with optimum pollutant removal efficiency. Turf grass should not be cut shorter than 3 to 5 inches and may be allowed to grow as tall as 12 inches depending on aesthetic requirements (NIPC, 1993). Forested filter strips do not require this type of maintenance. - Once a year, the soil will be aerated if necessary. - Once a year, soil pH will be tested and lime will be added if necessary. After the filter strip is established, it will be inspected quarterly and within 24 hours after every storm event greater than 1.0 inch (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potentialproblem: How to remediate theproblem: The entire BMP Trash/debris is present. Remove the trash/debris. The perimeter of the BMP Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then plant a erosive gullies have formed. ground cover and water until it is established. Provide lime and a one- time fertilizer application. Vegetation is too short or too Maintain vegetation at a height of approximately six inches. long. The flow splitter device (if The flow splitter device is Unclog the conveyance and dispose of any sediment off-site. applicable) clogged. The flow splitter device is Make any necessary repairs or replace if damage is too large for damaged. repair. The inlet device The pipe is clogged. Unclog the pipe. Dispose of the sediment off-site. The pipe is cracked or Replace the pipe. otherwise damaged. Erosion is occurring in the Regrade the swale if necessary to smooth it over and provide erosion swale. control devices such as reinforced turf matting or riprap to avoid future problems with erosion. Stone verge is clogged or Remove sediment and replace with clean stone. covered in sediment (if applicable). STORM -EZ 5/15/2018 /ersion 1.4 O&M Manual Page 1 of 2 771 The Swale and the level lip The swale is clogged with Remove the sediment and dispose of it off-site. sediment. The level lip is cracked, Repair or replace lip. settled, undercut, eroded or otherwise damaged. There is erosion around the Regrade the soil to create a berm that is higher than the level lip, and end of the level spreader that then plant a ground cover and water until it is established. Provide shows stormwater has lime and a one-time fertilizer application. bypassed it. Trees or shrubs have begun Remove them. to grow on the swale or just downslope of the level lip. The bypass channel Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then reestablish erosive gullies have formed. proper erosion control. Turf reinforcement is Study the site to see if a larger bypass channel is needed (enlarge if damaged or ripap is rolling necessary). After this, reestablish the erosion control material. downhill. The filter strip Grass is too short or too long Maintain grass at a height of approximately three to six inches. (if applicable). Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then plant a erosive gullies have formed. ground cover and water until it is established. Provide lime and a one- time fertilizer application. Sediment is building up on the Remove the sediment and restabilize the soil with vegetation if filter strip. necessary. Provide lime and a one-time fertilizer application. Plants are desiccated. Provide additional irrigation and fertilizer as needed. Plants are dead, diseased or Determine the source of the problem: soils, hydrology, disease, etc. dying. Remedy the problem and replace plants. Provide a one-time fertilizer application. Nuisance vegetation is Remove vegetation by hand if possible. If pesticide is used, do not choking out desirable species. allow it to get into the receiving water. The receiving water Erosion or other signs of Contact the NCDENR local Regional Office, or the 401 Oversight Unit damage have occurred at the at 919-733-1786. outlet. ;TORM-EZ 5/15/2018 fersion 1.4 O&M Manual Page 2 of 2 Important maintenance procedures: - The drainage area will be carefully managed to reduce the sediment load to the sand filter. - The sedimentation chamber or forebay will be cleaned out whenever sediment depth exceeds six inches. - Once a year, sand media will be skimmed. - The sand filter media will be replaced whenever it fails to function properly after maintenance. The sand filter shall be inspected quarterly and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potential problem: How to remediate the problem: Entire BMP Trash/debris is present. Remove the trash/debris. Adjacent pavement (if Sediment is present on the Sweep or vacuum the sediment as soon as possible. applicable) pavement surface. Perimeter of sand filter Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then plant a erosive gullies have formed. ground cover and water until it is established. Provide lime and a one- time fertilizer application. Vegetation is too short or too Maintain vegetation at an appropriate height. long. Flow diversion structure The structure is clogged. Unclog the conveyance and dispose of any sediment offsite. The structure is damaged. Make any necessary repairs or replace if damage is too large for repair. The inlet device The pipe is clogged. Unclog the pipe. Dispose of the sediment off-site. The pipe is cracked or Replace the pipe. otherwise damaged. Erosion is occurring in the Regrade the swale if necessary to smooth it over and provide erosion swale. control devices such as reinforced turf matting or riprap to avoid future problems with erosion. Stone verge is clogged or Remove sediment and replace with clean stone. covered in sediment (if applicable). Forebay or pretreatment Sediment has accumulated to Search for the source of the sediment and remedy the problem if area a depth of greater than six possible. Remove the sediment and stabilize or dispose of it in a inches. location where it will not cause impacts to streams or the BMP. Erosion has occurred. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If a pesticide is used, wipe it on the plants rather than spraying. Filter bed and underdrain Water is ponding on the Check to see if the collector system is clogged and flush if necessary. collection system surface for more than 24 If water still ponds, remove the top few inches of filter bed media and hours after a storm. replace. If water still ponds, then consult an expert. The outlet device Clogging has occurred. Clean out the outlet device. Dispose of the sediment off-site. The outlet device is damaged Repair or replace the outlet device. The receiving water Erosion or other signs of Contact the local NC Department of Environment and Natural damage have occurred at the Resources Regional Office. outlet. 'TORM-EZ 5/15/2018 /ersion 1.4 O&M Manual Page 1 of 1 Watershed Model Schematic Hydraflow Hydrographs Extension for AutoCADV Civil 3D®2018 by Autodesk, Inc. v12 Hyd rog ra p h Summary Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hydrograph Summary Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cult) Inflow hyd(s) Maximum elevation (ft) Total strge used (cult) Hydrograph Description 1 Rational 0.911 1 5 273 --- ---- --- Pre -development 2 Rational 2.071 1 5 621 --- ---- --- Post -development - To SF 3 Reservoir 0.007 1 10 619 2 256.59 618 Sand Filter 4 Rational 0.725 1 5 217 Post -development - By-pass SF 5 Combine 0.731 1 5 836 3,4 ----- ------ Post Development - Total 6 Combine 2.796 1 5 839 2, 4, --- ------ Post -development - No Control FAJOB\P-T\Triangle Pond Management- 19 13R'lfiffMt9F66 ager\Tri_Pon _,TJn d W4Wi66d126I1 VCDENR.gpw Hydrograph Summary Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D@ 2018 by Autodesk, Inc. v1 2 Hydrograph Summary Report Hydraflow Hydrographs Extension for AutoCAD®Civil 3D® 2018 by Autodesk, Inc. v12 Nitrogen Loading Calculations TrianWe Pond Manazement 3717 Overlook Road, Raleirh, North Carolina At time of development, 3717 Overlook Road is a vacant property. The site has been previously cleared and graded. The parcel is near the top of the sub -drainage basin and has limited off-site runoff flowing through the property. Runoff from the site is currently sheet flowing onto adjacent properties or collecting in a road -side swale. See Exhibit NL1 for pre -development loading map. An underground sandfilter is proposed for stormwater quantity and quality control. It has been sized for extended detention, and 35% nutrient reduction is being taken for area routed to the sandfilter. In the post -development condition, the sandfilter will serve a significant portion of the proposed project impervious area. See Exhibit NL2 for post -development loading map. Total Acres: 0.70 ac Post -development TN export > 10.0 lbs/ac/yr -Use Sandfilter to reduce Total Nitrogen Export Per NCDEMLR "Stormwater Design Manual" TN removal through Sandfilter -35% Proiect area nutrient loadinz (Post -development) Impervious - 0.45 ac (0.45 X 21.2) Open Space - 0.25 ac (0.25 X 1.20) Undisturbed - 0.00 ac (0.00 X 0.6) Total TN Unit Nitrogen Loading (0.70 ac) Reduction for Sandfdter: Impervious - 0.38ac (0.38 X 21.2 X 35%) Open Space - 0.02 ac (0.02 X 1.20 X 35%) Undisturbed - 0.00 ac (0.00 X 0.6 X 35%) Total TN Reduction for Pond Exported TN (9.84 lb/yr - 2.83 lb/yr) Total Loading AFTER BMPs (0.70 ac) = 9.54 (lb/yr) = 0.30 (lb/yr) = 0.00 (lb/yr) = 9.84 (lb/yr) = 14.1 Ib/ac/yr = 2.82 (lb/yr) = 0.01 (lb/yr) = 0.00 (lb/yr) = 2.83 (lb/yr) = 7.01 (lb/yr) = 10.0 lb/ac/yr Post -development TN export 10.0 lbs/ac/yr (< 10.0 lbs/ac/yr - OK) Nutrient Load Buvdown 10.0 lbs/ac/yr - 3.6 lb/ac/yr = 6.4 lbs/ac/yr (6.41bs/ac/yr) X (0.70 ac) = 4.481b/yr Total Nitrogen Load to by purchased (4.48 lb/yr X 30 yr) = 134.4 lbs 60' EX. R/W \ \ \ r 15 M/F UL OB MAIM 901 BM INN PO 50.7 Pw 1727.11-66-1679 / ` \ WE P / EX. 1 -STORY METAL / \ CNSTRUCIION LIMITS \\` (TIP) TEMPORARY f CONSTRUCTION \ENTRANCE 25'.50' * PROPOSED BUILDING 35.000 SF FFE 3261.4 ---- --. -- --261 TEMPORARY SILT FENCE 12' SLOPE EASEMENT TEMPORARY SILT FENCE oLTLEr (TVP) - ` x-261 - F rye IBP / / / SAL /M Do 15770. PC M 1982. 5931 PIN/ 1727.11-63-40.71 - / t / EC GRAVEL aOCN AND GRAVEL / WHET PROTECTION (TVP) EX. GRAVEL / / Ek 1 -STORY / FETA FEE 260.7 / I / EL GRAVEL �/ I FENCE OUTLET ELT _ FENCE ET /\ / •-' --_ _-_23„ 1 / SC LEDFR CHANCE FLOODPLAIN / / // / /yL� i SC/LED FROM WAKE COUNTY GIs'FLDODWAr FROM PANEL 37 MAY 2. 001. / / / / - _"1 \', \ EIP EFFECTIVE GATE WY 2, 2006 - � . _y L( EI. EDGE OF00PERRY GREEK ;� 7 M / TEPORIIRY SILT FENCE \\\ TIP\ CURVE TABLE O1RVE Mc LENGTH RADIUS arnD LENGTH aoaD TEAI9Hc C-1 _ 38.64 362-33 W-03 5 ]432 47 E cc -2 16.69 362.33 76.74 N ND215 W M RNq CLIMB, 11C D99 8005. PQ 104 1997. TIM 1997. -C ,965 3 PIM/ 1rn.,o46-11x GENERAL NOTES: EROSION CONTROL 1. BOUNDARY. SURVEY AND TOPOGR~ INFORMATION PROVIDED BY CAW HORNE MOSS AND PANCIERN, PC LAND SURVEYORS, PO BOX 1253. WAKE FOREST. NG PH 919.555.3140. DATED 3/29/2017. 2. FAILURE TO FOLLOW THESE APPROVED PIANS AND THE REGULATIONS, AND ORDINANCES OF CRY OF RALEIGH SEDIMENT AND EROSION CONTROL MAY RESULT N PENALTIES AND MMES. 3. CONTRACTOR SHALL AT ALL TIMES MAINTAIN AOFOUATE SAFETY MEASURES, ACTIVITIES. MID WRM10ES FOR THE PROTECTION OF ALL PERSONS ON OR ABOUT TIE LOCATION OF THE SITE 4. ALL PERMITS (INCLUDING MPDES PERMIT). APPROVALS, CERTIFICATES REPORTS AND MOTES, CERTIFICATES.AID SEED TAGS FROM ALL SEEDING O'EMTXNS SHALL BE RACED N THE ISPECrON BOX INSTALLED ON SITE. 5. ALL DENUDED AREAS 70 BE PERMANENTLY SEEDED PER ATTACHED SEEDING SCHEDULE. 6. ALL MEAS MOT COVERED WITH PAVING. GRAVEL, BINDING OR PLANTING BEDS SHALL BE SEEDED AS 94M N LE LANDSCAPE SEEDBED PREP. AND SEEDING SCHEDULE NOTES. (SEE THE PIAN FOR SPECIFIC LAWN AREAS). 7. INSPECT ALL SME MEASURES AT LEAST WEEKLY AND AFTER EACH M' RAINFALL IMMEDIATELY REPAIR ANY SEDIMENTATION AND EROSION CONTROL MEASURE THAT HAS FAILED, 8. SHOULD THE CITY OF RA MON SINE DEPARTMENT DETERMINE E EXCESSIVE SEDIMENT MAY BE LEAVING THE SITE, ADDRONAL SEDIMENTATION AND EROSION CONTROL MEASLA43 MAY BE REQUIRED, INCLUONG A REVISED SEDIMENTATION AND EROSION CONTROL PLAN. 9. A RE -INSPECTION FEE RLL BE ASSESSED SHOULD A RE-NSPECTIO/ BE NECESSARY DUE TO INCORRECT INSTALLATION. 10. TOPSOIL STOPPED FROM THE SITE IS TO BE STOCKRLED AND USED FOR BACKFLLNG AL LANDSCAPE ISLANDS, BEDS AND LAWN AREAS. TOPSOIL IS TO BE SPREAD TO A DEPTH OF AT LEAST C AS SOL 15 AVAILABLE. MOUND LANDSCAPE ISLANDS TO V ABOVE THE CURB AT THE CENTER OF THE ISLAND. 11. STOCKPILES SMALL HAVE A DOUBLE ROW OF sLT FENCE 10 FEET APART AT THE LIMITS OF THE APPROVED STOCKPILE AREA. TREES AND GROUNDCWER MAY BE REMOVED ONLY AS NECESSARY FOR THIS STOCKPILE. 12. UNTIL THE CRY HAS ACCEPTED THE COMPLETED CONSTRUCTION PHASE, THE CONTRACTOR RETAINS THE RESPONSIBILITY FOR MAINTAINING THE SAE DEVICES. ADDITIONALLY. THE CONTRACTOR RETAINS RESPONSIBILITY FOR ENSURING SAE INSPECTIONS ARE COMPLETED AT LEAST WEEKLY AND AFTER EACH %' RAINFALL FOR THESE DEVICES. 13. SITE STABILIZATION IS REQUIRED PRIOR TO FINAL APPROVAL AND ISSUANCE OF CERTIFICATE OF OCCUPANCY. GRASS UTILIZED AS PERMANENT GROUND COVER MUST BE AT A MOWABIE HEIGHT THAT GENERALLY PROVIDES AT LEAST 60% COVERAGE THROUGHOUT THE SITE. WITH NO LARGE BARE PATCHES OR EVIDENCE OF EROSION. CONSTRUCTION SEQUENCE FOR RALEIGH 1. SUBMIT DOOIIMEMATION REQUIRED UNDER RHE SITE WOES STORMWATER PERMIT FOR CONSTRLC710H ACTIVITY (NCWHIOODO) TO SFORMWATER INSPECTIONS THROUGHOUT THE PROJECT. 2. PRIOR TO BEGINNING CONSTRUCTION. CALL THE STORNWATER INSPECTIONS REGIONAL COORDINATOR AT (919) 279-13M TO SCHEDULE AN ON-SITE PRE -CONSTRUCTION MEETING. 3. INSTAL ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES. LIMIT CLEARING AND LAND DISTURB N0 ACTIVITY TO ONLY THE AREA NECESSARY TO INSTAL THE PERMITTED MEASURES, 4. CALL THE RAPID RESPONSE HUMBER (919) 957-4412 TO SCHEDULE A STOHMWATER SITE ISPECTION. 5. UPON APPROVAL OF THE STORYNATER SITE INSPECTION. COMMENCE PERYIRED LAND DISTURBING ACTIVITY. 6. ALL EROSION CONTROL MEASURES "'ALL BE INSPECTED AND MAINTAINED. IF NEEDED. AT LEAST ONCE PER WEEK AND AFTER EVERY RAINFALL EVER (R . 7. GROUND COVER SIAL BE PROVIDED AS FOLLOWS: FOR ALL MEAS OF MODERATE ARD/OR STEEP sLopEs PROVIDE TEMPORARY GROUND COVER F THE SLOPE HAS HOT BEEN DISTURBED FOR A PERIOD OF IDURIEEN (14) DAYS. D. PROVIDE GROUND COVER SUFFICIEO TO RESTRAIN EROSION ON ANY PORTION OF THE SITE UPON WIN FURTER LAND-DISWMNG ACTMTY IS NOT BEING UNDERTAKEN WITHIN FOURTEEN (14) CALENDAR DAYS OF TEYPORARL.Y OR PERhw*HTLY SUSPENDING LAND 00TURI NG ACTIVITY. c STABILIZATION Is REOUfED WITHIN 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING OR INACTIVITY ON PROJECT SRTE 9.BEEN ROUGH GRADE SITE 10. BEGIN INSTALLATION OF STORM PIPE SYSTEM AND SAEDFLTER STRUCTURE. CO NOT INSTALL SAND UNTIL AFTER SffE IS STABILIZED. 11. INSTALL TEMPORARY INLET PROTECTION AT STRUCTURES AS THEY ARE COMPLETED. 12. MAINTAIN ALL EROS04 AND SEDIMENT CONTROL MEASURES N GOOD WORKING ORDER. SILT FENCE, INLET PROTECTION AND OTHER SNLAR MEASURES MUST BE CLEANED OUT BEFORE THEY ME HALF FULL CLOGGED STONE FILTERS MIST BE REFRESHED/REPLACED. SILT FENCE CANNOT HAVE HOFS OR TEARS. 13. STABIUZATION S REWIRED WITHIN 14 CAFMOAR DAYS OF COMPLETION OF ANY PHASE OF GRADING OR IN4CTA71Y ON PROJECT SITE. 14. AS SITE S BROUGHT UP TO FINAL GRADE. BEGIN BUILDING CONSTRUCTION AND STABILIZE DISTURBED AREAS WITH PAVING OR VEGETATION, AS SHOWN. 15. WHEN CONSTRUCTIONS COMPLETE AND ALL REAS ARE STAINUZED COMPLETELY. CALL FOR INSPECTION BY STORYWATER INSPECTOR, 919-279-1309 WESTERN REGION. 19. F APPROVED. REMgE SEDMIETf FROM SAID FILTER SIRIICNRE AND INSTALL SVD. ALL UPSTREAM REAS MUST BE SAINUZED PRIOR TO FINISHING SAIDFILTER INSTALLATION. SEE SHEETS C3.0 AND C7.2 FOR sANDFLTER DESIGN AND DETAILS. 17. WHEN 51ADTLTER NSTALLATION S MPI COLETE, CALL FOR INSPECTION BY SIDRYWATER INSPECTOR 919-279-1309, WESTERN REGION. IS. F SITE S APPROVED. REMOVE ANY REMAINING TEMPORARY DEVICIS, TREE PROTECTION/SILT FENCE AND SEED OMIT OR PAVE ANY RESULTING FARE MFRS. 19. SITE SIABILIZATXN IS REOURED PRIOR TO FINAL APPROVAL O GRADING PERMIT AND ISSUANCE OF CERTIFICATE OF OCCUPANCY. GRASS UAL® AS PERMANENT GROIMD COVER MUST BE AT A MO'WANZ HEIGHT THAT GENERALLY PROVIDES AT LEAST 903 COVERAGE THROUGHOUT THE SITE. WIN ND LARGE BARE PATCHES OR EVIDENCE OF EROSION. 20. AT A MINIMUM OF SEVEN (7) CALENDAR DAYS PRIOR TO SO4EDULIIG THE STORMWATER FINAL INSPECTION. 'SUBMIT A CRM Y OF RALEIGH FORM 511 D APPROVABLE BM MP AS -BUILT PLAN D ENWNMM CERTIFICATION TO CRY OF RALEIGH STAFF FOR REVIEW AND WRITTEN ACCEPTANCE THE CERTWICAT10NS MUST BE ACCEPTED PRIOR TO A CERTIFICATE O OCCUPANCY BEING ISSUED. 21. IF APPLICABLE, IMPERVIOUS SURVEY SUBMITTAL, RENEW AND ACCEPTANCE 15 REQUIRED PRIOR TO APPROVAL OF FNAL WATERSHED PERMIT INSPECTION CA . 22- LL THE RAPID RESPONSE NUMBER (919) 957-4412 TO SCHEDULE A sTORMNATER FINAL INSPECTION. 23. ONCE THE 5TORMMTER FINAL INSPECTION IS APPROVED. CLOSE THE GRADING PERMIT AND OBTAIN A CERTIFICATE OF COMPLETION DISTURBED AREA 0.71 ACRE CONTROL LEGEND O ONSIIWLC00N EIR 1 * - 'i Fx - - - - CONSTRUCTION LIMITS w \ ® INLET PROTECTION 20 d _ TEMPORARY SILT FENCE 12' SLOPE EASEMENT TEMPORARY SILT FENCE oLTLEr (TVP) - ` x-261 - F rye IBP / / / SAL /M Do 15770. PC M 1982. 5931 PIN/ 1727.11-63-40.71 - / t / EC GRAVEL aOCN AND GRAVEL / WHET PROTECTION (TVP) EX. GRAVEL / / Ek 1 -STORY / FETA FEE 260.7 / I / EL GRAVEL �/ I FENCE OUTLET ELT _ FENCE ET /\ / •-' --_ _-_23„ 1 / SC LEDFR CHANCE FLOODPLAIN / / // / /yL� i SC/LED FROM WAKE COUNTY GIs'FLDODWAr FROM PANEL 37 MAY 2. 001. / / / / - _"1 \', \ EIP EFFECTIVE GATE WY 2, 2006 - � . _y L( EI. EDGE OF00PERRY GREEK ;� 7 M / TEPORIIRY SILT FENCE \\\ TIP\ CURVE TABLE O1RVE Mc LENGTH RADIUS arnD LENGTH aoaD TEAI9Hc C-1 _ 38.64 362-33 W-03 5 ]432 47 E cc -2 16.69 362.33 76.74 N ND215 W M RNq CLIMB, 11C D99 8005. PQ 104 1997. TIM 1997. -C ,965 3 PIM/ 1rn.,o46-11x GENERAL NOTES: EROSION CONTROL 1. BOUNDARY. SURVEY AND TOPOGR~ INFORMATION PROVIDED BY CAW HORNE MOSS AND PANCIERN, PC LAND SURVEYORS, PO BOX 1253. WAKE FOREST. NG PH 919.555.3140. DATED 3/29/2017. 2. FAILURE TO FOLLOW THESE APPROVED PIANS AND THE REGULATIONS, AND ORDINANCES OF CRY OF RALEIGH SEDIMENT AND EROSION CONTROL MAY RESULT N PENALTIES AND MMES. 3. CONTRACTOR SHALL AT ALL TIMES MAINTAIN AOFOUATE SAFETY MEASURES, ACTIVITIES. MID WRM10ES FOR THE PROTECTION OF ALL PERSONS ON OR ABOUT TIE LOCATION OF THE SITE 4. ALL PERMITS (INCLUDING MPDES PERMIT). APPROVALS, CERTIFICATES REPORTS AND MOTES, CERTIFICATES.AID SEED TAGS FROM ALL SEEDING O'EMTXNS SHALL BE RACED N THE ISPECrON BOX INSTALLED ON SITE. 5. ALL DENUDED AREAS 70 BE PERMANENTLY SEEDED PER ATTACHED SEEDING SCHEDULE. 6. ALL MEAS MOT COVERED WITH PAVING. GRAVEL, BINDING OR PLANTING BEDS SHALL BE SEEDED AS 94M N LE LANDSCAPE SEEDBED PREP. AND SEEDING SCHEDULE NOTES. (SEE THE PIAN FOR SPECIFIC LAWN AREAS). 7. INSPECT ALL SME MEASURES AT LEAST WEEKLY AND AFTER EACH M' RAINFALL IMMEDIATELY REPAIR ANY SEDIMENTATION AND EROSION CONTROL MEASURE THAT HAS FAILED, 8. SHOULD THE CITY OF RA MON SINE DEPARTMENT DETERMINE E EXCESSIVE SEDIMENT MAY BE LEAVING THE SITE, ADDRONAL SEDIMENTATION AND EROSION CONTROL MEASLA43 MAY BE REQUIRED, INCLUONG A REVISED SEDIMENTATION AND EROSION CONTROL PLAN. 9. A RE -INSPECTION FEE RLL BE ASSESSED SHOULD A RE-NSPECTIO/ BE NECESSARY DUE TO INCORRECT INSTALLATION. 10. TOPSOIL STOPPED FROM THE SITE IS TO BE STOCKRLED AND USED FOR BACKFLLNG AL LANDSCAPE ISLANDS, BEDS AND LAWN AREAS. TOPSOIL IS TO BE SPREAD TO A DEPTH OF AT LEAST C AS SOL 15 AVAILABLE. MOUND LANDSCAPE ISLANDS TO V ABOVE THE CURB AT THE CENTER OF THE ISLAND. 11. STOCKPILES SMALL HAVE A DOUBLE ROW OF sLT FENCE 10 FEET APART AT THE LIMITS OF THE APPROVED STOCKPILE AREA. TREES AND GROUNDCWER MAY BE REMOVED ONLY AS NECESSARY FOR THIS STOCKPILE. 12. UNTIL THE CRY HAS ACCEPTED THE COMPLETED CONSTRUCTION PHASE, THE CONTRACTOR RETAINS THE RESPONSIBILITY FOR MAINTAINING THE SAE DEVICES. ADDITIONALLY. THE CONTRACTOR RETAINS RESPONSIBILITY FOR ENSURING SAE INSPECTIONS ARE COMPLETED AT LEAST WEEKLY AND AFTER EACH %' RAINFALL FOR THESE DEVICES. 13. SITE STABILIZATION IS REQUIRED PRIOR TO FINAL APPROVAL AND ISSUANCE OF CERTIFICATE OF OCCUPANCY. GRASS UTILIZED AS PERMANENT GROUND COVER MUST BE AT A MOWABIE HEIGHT THAT GENERALLY PROVIDES AT LEAST 60% COVERAGE THROUGHOUT THE SITE. WITH NO LARGE BARE PATCHES OR EVIDENCE OF EROSION. CONSTRUCTION SEQUENCE FOR RALEIGH 1. SUBMIT DOOIIMEMATION REQUIRED UNDER RHE SITE WOES STORMWATER PERMIT FOR CONSTRLC710H ACTIVITY (NCWHIOODO) TO SFORMWATER INSPECTIONS THROUGHOUT THE PROJECT. 2. PRIOR TO BEGINNING CONSTRUCTION. CALL THE STORNWATER INSPECTIONS REGIONAL COORDINATOR AT (919) 279-13M TO SCHEDULE AN ON-SITE PRE -CONSTRUCTION MEETING. 3. INSTAL ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES. LIMIT CLEARING AND LAND DISTURB N0 ACTIVITY TO ONLY THE AREA NECESSARY TO INSTAL THE PERMITTED MEASURES, 4. CALL THE RAPID RESPONSE HUMBER (919) 957-4412 TO SCHEDULE A STOHMWATER SITE ISPECTION. 5. UPON APPROVAL OF THE STORYNATER SITE INSPECTION. COMMENCE PERYIRED LAND DISTURBING ACTIVITY. 6. ALL EROSION CONTROL MEASURES "'ALL BE INSPECTED AND MAINTAINED. IF NEEDED. AT LEAST ONCE PER WEEK AND AFTER EVERY RAINFALL EVER (R . 7. GROUND COVER SIAL BE PROVIDED AS FOLLOWS: FOR ALL MEAS OF MODERATE ARD/OR STEEP sLopEs PROVIDE TEMPORARY GROUND COVER F THE SLOPE HAS HOT BEEN DISTURBED FOR A PERIOD OF IDURIEEN (14) DAYS. D. PROVIDE GROUND COVER SUFFICIEO TO RESTRAIN EROSION ON ANY PORTION OF THE SITE UPON WIN FURTER LAND-DISWMNG ACTMTY IS NOT BEING UNDERTAKEN WITHIN FOURTEEN (14) CALENDAR DAYS OF TEYPORARL.Y OR PERhw*HTLY SUSPENDING LAND 00TURI NG ACTIVITY. c STABILIZATION Is REOUfED WITHIN 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING OR INACTIVITY ON PROJECT SRTE 9.BEEN ROUGH GRADE SITE 10. BEGIN INSTALLATION OF STORM PIPE SYSTEM AND SAEDFLTER STRUCTURE. CO NOT INSTALL SAND UNTIL AFTER SffE IS STABILIZED. 11. INSTALL TEMPORARY INLET PROTECTION AT STRUCTURES AS THEY ARE COMPLETED. 12. MAINTAIN ALL EROS04 AND SEDIMENT CONTROL MEASURES N GOOD WORKING ORDER. SILT FENCE, INLET PROTECTION AND OTHER SNLAR MEASURES MUST BE CLEANED OUT BEFORE THEY ME HALF FULL CLOGGED STONE FILTERS MIST BE REFRESHED/REPLACED. SILT FENCE CANNOT HAVE HOFS OR TEARS. 13. STABIUZATION S REWIRED WITHIN 14 CAFMOAR DAYS OF COMPLETION OF ANY PHASE OF GRADING OR IN4CTA71Y ON PROJECT SITE. 14. AS SITE S BROUGHT UP TO FINAL GRADE. BEGIN BUILDING CONSTRUCTION AND STABILIZE DISTURBED AREAS WITH PAVING OR VEGETATION, AS SHOWN. 15. WHEN CONSTRUCTIONS COMPLETE AND ALL REAS ARE STAINUZED COMPLETELY. CALL FOR INSPECTION BY STORYWATER INSPECTOR, 919-279-1309 WESTERN REGION. 19. F APPROVED. REMgE SEDMIETf FROM SAID FILTER SIRIICNRE AND INSTALL SVD. ALL UPSTREAM REAS MUST BE SAINUZED PRIOR TO FINISHING SAIDFILTER INSTALLATION. SEE SHEETS C3.0 AND C7.2 FOR sANDFLTER DESIGN AND DETAILS. 17. WHEN 51ADTLTER NSTALLATION S MPI COLETE, CALL FOR INSPECTION BY SIDRYWATER INSPECTOR 919-279-1309, WESTERN REGION. IS. F SITE S APPROVED. REMOVE ANY REMAINING TEMPORARY DEVICIS, TREE PROTECTION/SILT FENCE AND SEED OMIT OR PAVE ANY RESULTING FARE MFRS. 19. SITE SIABILIZATXN IS REOURED PRIOR TO FINAL APPROVAL O GRADING PERMIT AND ISSUANCE OF CERTIFICATE OF OCCUPANCY. GRASS UAL® AS PERMANENT GROIMD COVER MUST BE AT A MO'WANZ HEIGHT THAT GENERALLY PROVIDES AT LEAST 903 COVERAGE THROUGHOUT THE SITE. WIN ND LARGE BARE PATCHES OR EVIDENCE OF EROSION. 20. AT A MINIMUM OF SEVEN (7) CALENDAR DAYS PRIOR TO SO4EDULIIG THE STORMWATER FINAL INSPECTION. 'SUBMIT A CRM Y OF RALEIGH FORM 511 D APPROVABLE BM MP AS -BUILT PLAN D ENWNMM CERTIFICATION TO CRY OF RALEIGH STAFF FOR REVIEW AND WRITTEN ACCEPTANCE THE CERTWICAT10NS MUST BE ACCEPTED PRIOR TO A CERTIFICATE O OCCUPANCY BEING ISSUED. 21. IF APPLICABLE, IMPERVIOUS SURVEY SUBMITTAL, RENEW AND ACCEPTANCE 15 REQUIRED PRIOR TO APPROVAL OF FNAL WATERSHED PERMIT INSPECTION CA . 22- LL THE RAPID RESPONSE NUMBER (919) 957-4412 TO SCHEDULE A sTORMNATER FINAL INSPECTION. 23. ONCE THE 5TORMMTER FINAL INSPECTION IS APPROVED. CLOSE THE GRADING PERMIT AND OBTAIN A CERTIFICATE OF COMPLETION DISTURBED AREA 0.71 ACRE CONTROL LEGEND !jERR�OSS(J�KK/j L_1_l-L_l N�r1 ��------ ONSIIWLC00N EIR 1 * - SILT FENCE - - - - CONSTRUCTION LIMITS w SLY FENCE OUTLET ® INLET PROTECTION APPROVED FOR PERMITTING NOT FOR CONSTRUCTION CALL BEFORE YOU DIGI NORTH LIN CAROA LAW REOURES NOTFO ICATN OF THElINOERDROUND FACILITY DINNER HOT LEM THW Two R) BUT NO MORE THAN TEN Tq WORKNO DAYS PRIOR TO EXCAVATION OR DEMOLITDN RTH CARO 11 www.nc8ll.org 1-800-632-4949 North Carolina OnaCall *rltar. Inc. REVISIONS NO. DATE I DESCRIPTION REV. BY KqH 11111 „ •�A36 '� jEF EO N3pi aif oil! COORDIalrtNATORlan: Blair P DR)r BY: HK BY: BPP Z 5W W Z 5� M Z J ❑ wO O fro LU P J ow C.7 wi °z Z�= O W ~ J 24X36 1'20' 10 MAY 2018 1953-0072 EROSION CONTROL PLAN v PAVEMENT DESIGN FOR DRIVEWAY IN PUBLIC ROW \ \ 3' S9.5A ON 8- CABC \ ` ` V fist•]�flf!1[1fi�s�s���w�l�������GI!m�F7F'_r7 E�T��nri`,-�ssnrttr>s%a�csaElFc�T:c�[T-1_[Tr�>•Txti_Es<'ai'x�>_cz�.��xs..t•��� �� TSI�r.TrFaTD1r.-.ts (LAID N TWO LIFTS) � 19a�� �� �� It•�����F7'r1O51 :, :: a iw .Iw r.To:,•�TT:T:�cay.�';cly�� riT3E:�«a., cr•,L Z��T3LT• F1•tlf:f.':�SSFIL'.'LiIIPT�I♦iFY7n4L�Li�[Ll•[If�DkYiElf•�['7Gl�C?P<.L�i>:'11sia�l��:. ��TSri��9[�=�5��������T���%%�r�r)���Fi-)♦.I .::a: Jaw ., .Iw ..�.l .. r H ..`. Y..+..n e:..R c��i�f5rissnrr: inc:�sFsasR.%a�r�ET-�oT>.TiE��crt�Eir.>_r�r�' acecl���Ill9� :, :: ' iw Iw \ _ 19,Y FP/E1' ` FRE -N -LIEU OF CONSTRUCTION FOR a A 48' B/B ROM WITH 6' RIO' IX R/W W �r- ` � CRETE SI ALK FRONTAGE 3- S9. 110 LF 3" 59.58 ON B' ABC ROAD SECTION •7FFiRF���� u :: a� _•ea1� .:.Lw iaTf�l:l]1�SSF7� B�yll_>.�SS�T.���T����T��T�t1sT���fr,^.-:[^:�:�Z7E3:•:�]lr: 12' SLOPE FAglE7R �2- _ EDGE OF ASPHALT PAVEMENT (TYP) ASPHALT PATCH MEDIUM DRY ASPHALT PAVING' ON INV. OUT: (� _ f .34 _ 3"-S9.58 SURFACE COURSE B" ABC (TYP) _ `. `` ' - _ - DUTY ASPHALT PAVING 2 ' S B' ABC t\� \S \ J -U2' NV. GUY: 1-6,DN t6 (PYP MATCH) O HAT - \ 5)f.88' SO®Vg'S. ITC SIDEWALK 10 BE RUSH WITH ADJACENT PAVEMENT -- - �' / ` 6 ) � S - 259 �' / 259.23�- PG 901 TIM /4982. PG 593 5' CONCRETE SIDEWALK OWJ t\ t` -F` Ry5 •R� /'INV. OUT: - PH/ 1727.11-55-1579 / x • C-1 ( 1 C `b h / -1 -260_ I EIP M�R cON57RUC110N L91ns IX`�/ 260. 6 I ( / wFwl9Tl I / 1 / HANDICAPARKP ING AND LOOPING ARRA MAX 2% ` �• \ ,./ 6 SLOPE - ANT DWECTION 7 Y/ - 1.2 e. NEN EDGE OF ASPHUT PAVING TO BE FLUSH N/F WITH EXISTING ADJACENT SAL REAS ESTAIF LLD / WAC PAD .26i.2 , - , / GRAVEL PARKING pB1WT51 9M PO 503 P 6i 35 / � PN/ 1727.11 -SS -4631 / 10' CONCRETE / / MUTCD R7-8 R R7 -81D 61. SIDEWALK / EX GRAVEL HANDICAP SIGNS WITH VAN GENERAL NOTES: GRADING PLAN 1. BOUNDARY. SURVEY AND TOPOGRAPHIC INFORMATION PRONGED BY CAWDRIRNE. MOSS AND PANCIERIA, PC LAND SURVEYORS. PO BOX 1253. MAKE FOREST. NC. PN 919.556.3146. DATED 3/29/2017, 2. SAID FILTER TO RETAIN STORMWATER RT -Q" To PRE-DEVFLOPMIXT CONDITIONS FOR THE 1 YEAR. 2 YEAR. 6 10 YEAR STORM EVENTS. DRY DETENTION TO PROVIDE NITROGEN REMOVAL, BASED ON CRY OF RALEIGH STANDARDS. PER STORMWATER MANUAL. AND THE MOST CURRENT VERSION OF THE NCDENR BMP MANUAL ORIGINALLY DATED 2007. 3. THE REFERENCED BMPS SHOWN AND LOCAL ORDINANCES IMPOSE CERTAIN OOMINUING INSPECTION. MAINTENANCE REPAIR AND OBER REQUIREMENTS UPON THE OWNER, LATER INITIAL CERTIFICATION OR CERTIFICATE OF OCCUPANCY. THESE PAINS DO NOT INCLUDE ANY RESPONSIBILITY ON THE PART OF THE CONTRACTOR TO COMPLY WITH TIDY REQUIREMENTS ON THE OWNER'S BEHALF. 4. CONTRACTOR SHRILL SECURE ALL NECESSARY PERMITS FOR CONSTRUCTION 910WN ON THEY PLANS. 5. CONTRACTOR SHALL AT ALL TIMES MAINTAIN ADEQUATE SAFETY MEASURES, ACTIVITIES. AND BARRICADES FOR THE PROTECTION OF ALL PERSONS ON OR ABOUT THE LOCATION OF THE SITE S. CONTRACTOR SHALL PERRY EXISTING CONDITIONS PRIOR TO BEGN ONG CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES - 7. GRADING MORE THAN ONE ACRE OF AN APPROVED EROSION CONTROL PIAN IS A VIOLATION AND IS SUBJECT TO A FINE 8. TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY LAND DISTURBANCE AND SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH. AS FOLLOWS. -NO TRESPASSIMG/TREE PROTECTION AREA/PROHIBIDO ENTRAR/ZONA PROTECTORA PMA LDS ARBOLES.- 9. ~NG BEYOND THE DENUDED LINTS INDICATED ON CONSTRUCTION DOCUMENTS IS A VIOLATION AND IS SUBJECT TO A FINE 10. ALL EXISTING UTILITIES AND STORM STRUCTURES ARE 94OW N PER SURVEY DATA AND ME APPROXIMATE CONTRACTOR IS FULLY RESPONSIBLE TO FIELD VERIFY ACTUAL LOCATION AND DEPTH OF EXISTING UTILITIES PRIOR TO THE STMT OF CONSTRUCTION AND 5lWL CALL UTILITY LOCATOR 10 VERIFY LOCATION OF ALL EXISTING UTILITIES. 11. AL SIOEWAUM STOOPS, TERRACES AND OTHER PAVED AREAS SHALE SLOPE AWAY FROM BUILDING(S) AT 2X(MIN). 12. THE CONTRACTOR SHALL MAINTAIN EACH DITCH IN AN UNOBSTRUCTED CONDITION AND SHALL REMOVE FROM THESE MEAS ALL DEBRIS, LOGS. TIMBER. TRASH. JUNK AID OBER ACCUMULATIONS. 13. TOPSOIL STRIPPED FROM THE SITE IS TO BE STOCKPILED AND USED FOR BACKFILLING ALL LANDSCAPE SANDS SEDS AND LAWN AREAS. TOPSOIL IS To BE SPREAD TO A DEPTH OF AT LEAST 6' AS SOIL IS AVAILABLE 14. ALL MFRS NOT COVERED WITH PAVING. GRAVEI. BUILDING OR PLANING BEDS SHALL BE SEEDED AS SNOWN IN THE SEEDBED PREP. AND SEEDING SCHEDULE NOTES. (SEE THE LANDSCAPE PLCO FOR SPMFIC LAWN MEAS) 15. ALL CONSTRUCTION TO BE PERFORMED TO THE CITY OF RALEIGH DESIGN AND CONSTRUCTION STANDARDS. / ACSIGN ATTACHED TO WILDING / 20' PRIVATE DRAINAGE / EASEMENT AFROM BMP TO R/W (FO / (FOR ACCESS TO BMP) J 1h/ 281. 80.0 NYOPLASf IEAW WISE BASIN AND / EX. 1 -STORY h / 2Y GRATE (N20) METAL PROPOSED / TYP OF 4 �Y 500BUILDING 261. / / }E±2 1. - ROOF DRAIN LEADER / IX GRAVEL 6' HDPE O t% MIN SLOPE FIFE }261A Y / 5' WIDE CONCRETE SIDEWAX J PROPOSED - - - - - - - - - - - - 2b1 / \ \ / / / CRANE / 5' THICKNESS 3261.]622 SI.P (PYP ALONG ORNE-N DOOR SIDE / 281. / .5 / / OF BUILDING) \l60\ }261.50 t6l'7.5' 8 2% S. 28th P GRAVEL AREA C IW 2' 11' as 6' DEPTH ABC w (lYP OF MATCHED AREA)\ `\� 61.2 281. / W w ` ­Ry w I 5 3 Iw FEE - 260.7' / m g METAL 261 y 261 50.5 5'u" CONCRETE INLETS COLLAR S TYP OF OF n LOCATED IN GRAVEL AREA TYPICAL ROAD SECTION scuE v: 1' - 5 O / 1WRTUE 2 -RANT UI9mID H: 1' � 10' 250 _ X60.7a7D �7Flp •® EX. GRAVEL cmou - PP ` • "ACE •, DESIGN STORM FEOUENCY - 10 YR. C - AS NOTED 0.012'(RCPJ ARCP• REINFORCED CONCRETE PIPE C.B. CATCH BION F.S. - FLOW SPLITTER SEPARATION STORM SYSTEM - 0.010 (NOPE) HDPE- F9GH DENSITY POLYEMEENE SMOOTH CORE DOUBLE MULLED PPE D.I. - DROP INLET 6 _-AND EXISTING SANITARY SEWER 6r S _ ` GREATER THAN 20 FE / \ d' / h / PEAK hOW FOR THE 1 -YEAR \\ •P� d 20• p�.� / STORM S 0.008 CFS AND 2.48 CFS / FOR ME 10 -TRIC STDRM. RIP -FRP PROTECTION PROVIDED FOR SLOPE I PROTECTION / T EP -_----- o / /\ / i _ � X255_--__ � -__ j_ -fir •`` _/sol] - / 16• HDPE ROOF DRAIN - MPROX 190 LF AREA RESERVED FOR POTENTN i - - FUTURE ACQUISITION BY THE CITY /// / / / / - - - _ - - - - _ - - - FOR GRESWfAY ACCESS. // ��/i ��/ -245- - - - A_-7 - CALL BEFORE YOU DIGI IN EFFECT FOR ONE YEAR FROM / // / / // j - �� ' - - _ -3? -- - -� ' - ' - NORTH CAROLINA LAW REQUIRES NOTIFICATION OF CAPE OF SRIF PLM APPROVAL // /�/ -- - _ - - - - - - _ a ��� I� . - 2 l� �_ `- 250 �_' _ THE UNDERGROUND FACILITY OWNER NOT LESS ANNUAL CHANCE FLOODPLAIN j/ //� j� - __ - - - J -- y� S \ ` `-- IX _ THAN TM (2) BUT NO MORE THAN TEN (10) SCALED FROM WAKE COUNTY GS / / "Al / OO i ",Qj 2 �b _ \ - -- _ - KING DAYS PRIOR TO EXCAVATION OR FROM PANEL 37201727001. - / ///� / - _ - _ __. - - - _ _ DEMOLITION EFFECTIVE DATE MAY 2. 2006 J /�/ / _ / _ \R `\EIP -� \�� = zs__ RTH CARO E - / EDGE OF WATER ���, ��, •�S00 \ 1 •� WWW.nC811.0� ���\ 1-80032 4949 v�DTrCHAXIMD SWALE mac'' CREEK 'Or FOP -PAP- \\� � � A �R'6g1 w \ + North Carolina On*Call Gerlier Inc. 10 If CONCRETE LEVELSPREADIER RAUEIGIL 5H9 CLIMB, LED APPROVED FOR CURVE TABLE LIB IM7.awsC 194 CURVE MC LENGTH RADIUS CHORD LENGTH CHORD BEADING BM 1�' - 1911 PERMITTING C-1 36.84 1 762.33 36.63 S 7432'4 _ E P91j 1727.10-4!H7184 I C� /6.89' 362.33 76.]4'_.1. N_B4O715- NOT FOR CONSTRUCTION REVISIONS No. DATE DESCRIPTION REV. BY 0 0 r�YCF o�ys_IO r, '4y�ArR P ��d SS 8d� p� COORDINATOR: Blair PInTTBn DRAM BY: HK BY:BPP Z W m W Z 5� c Zp0 O < X a- 00 W 0 ISE 00 V /1/ L LU /= 0> W �~ J M< 24X36 10 MAY 2018 1953-0072 GRADING PLAN BA2.0 - • , r 4a' D• •' V fist•]�flf!1[1fi�s�s���w�l�������GI!m�F7F'_r7 E�T��nri`,-�ssnrttr>s%a�csaElFc�T:c�[T-1_[Tr�>•Txti_Es<'ai'x�>_cz�.��xs..t•��� �� TSI�r.TrFaTD1r.-.ts � s � 19a�� �� �� It•�����F7'r1O51 :, :: a iw .Iw r.To:,•�TT:T:�cay.�';cly�� riT3E:�«a., cr•,L Z��T3LT• F1•tlf:f.':�SSFIL'.'LiIIPT�I♦iFY7n4L�Li�[Ll•[If�DkYiElf•�['7Gl�C?P<.L�i>:'11sia�l��:. ��TSri��9[�=�5��������T���%%�r�r)���Fi-)♦.I .::a: Jaw ., .Iw ..�.l .. r H ..`. Y..+..n e:..R c��i�f5rissnrr: inc:�sFsasR.%a�r�ET-�oT>.TiE��crt�Eir.>_r�r�' acecl���Ill9� :, :: ' iw Iw F�i7♦I:f':�SSIT7IFICSI•i7GY7i><'�fi�[Fif16�C7C['C1D7♦C�1(''iT•:•iFT��x1♦�Il� ;, -: a: J •. L_a f•.T.•7SSS�s�GS�[Tl•QG����Fzi1F •7FFiRF���� u :: a� _•ea1� .:.Lw iaTf�l:l]1�SSF7� B�yll_>.�SS�T.���T����T��T�t1sT���fr,^.-:[^:�:�Z7E3:•:�]lr: �7[1ES�Tr1�7TF7Ti.1��TfF��I♦��T�iE-�i-7FFS1Fif�tl� �2- / 16• HDPE ROOF DRAIN - MPROX 190 LF AREA RESERVED FOR POTENTN i - - FUTURE ACQUISITION BY THE CITY /// / / / / - - - _ - - - - _ - - - FOR GRESWfAY ACCESS. // ��/i ��/ -245- - - - A_-7 - CALL BEFORE YOU DIGI IN EFFECT FOR ONE YEAR FROM / // / / // j - �� ' - - _ -3? -- - -� ' - ' - NORTH CAROLINA LAW REQUIRES NOTIFICATION OF CAPE OF SRIF PLM APPROVAL // /�/ -- - _ - - - - - - _ a ��� I� . - 2 l� �_ `- 250 �_' _ THE UNDERGROUND FACILITY OWNER NOT LESS ANNUAL CHANCE FLOODPLAIN j/ //� j� - __ - - - J -- y� S \ ` `-- IX _ THAN TM (2) BUT NO MORE THAN TEN (10) SCALED FROM WAKE COUNTY GS / / "Al / OO i ",Qj 2 �b _ \ - -- _ - KING DAYS PRIOR TO EXCAVATION OR FROM PANEL 37201727001. - / ///� / - _ - _ __. - - - _ _ DEMOLITION EFFECTIVE DATE MAY 2. 2006 J /�/ / _ / _ \R `\EIP -� \�� = zs__ RTH CARO E - / EDGE OF WATER ���, ��, •�S00 \ 1 •� WWW.nC811.0� ���\ 1-80032 4949 v�DTrCHAXIMD SWALE mac'' CREEK 'Or FOP -PAP- \\� � � A �R'6g1 w \ + North Carolina On*Call Gerlier Inc. 10 If CONCRETE LEVELSPREADIER RAUEIGIL 5H9 CLIMB, LED APPROVED FOR CURVE TABLE LIB IM7.awsC 194 CURVE MC LENGTH RADIUS CHORD LENGTH CHORD BEADING BM 1�' - 1911 PERMITTING C-1 36.84 1 762.33 36.63 S 7432'4 _ E P91j 1727.10-4!H7184 I C� /6.89' 362.33 76.]4'_.1. N_B4O715- NOT FOR CONSTRUCTION REVISIONS No. DATE DESCRIPTION REV. BY 0 0 r�YCF o�ys_IO r, '4y�ArR P ��d SS 8d� p� COORDINATOR: Blair PInTTBn DRAM BY: HK BY:BPP Z W m W Z 5� c Zp0 O < X a- 00 W 0 ISE 00 V /1/ L LU /= 0> W �~ J M< 24X36 10 MAY 2018 1953-0072 GRADING PLAN BA2.0 OF r —10'� 0 1'X4' OPENING VIER 1 T_ WIER 2 0 2.5 5 10 15 SCALE 1"=5' WIER SECTIONS >� MANNOIE COWER 15' HOPE INLET FROM STRUCTURE 3 15' HDPE OUTLET WEIR TO SANDFILTER 10' HDPE OUTLET TO FES (STRUCTURE 1) 266.86 SECTION 15' HOPE INLET FROM STRUCTURE 3 15' HOPE OUTLET TO SANDFILTER WEIR /8' HOPE OUTLET PLAN TO FES (STRICTURE 1) FLOW SPLITTER N.T.S. V SON 40 OR SOR 35 SMOOTH WALL PERFORATED P,C DROWN PIPF. MINIMUM 4 ROWS AROUND DIAMETER OE PIPE, e' O.C. WITHIN EACH ROW FOR ENTIRE LENGTH OF PIPE, PEFFORAT10N5 SHALL BE r' DIAMETER. OTHER POPE CAN BE USED AS LONG AS OPENINGS ARE MIN 0.664 INA/FT (TMP OF 3) UNDERORNN PIPES SHALL HANE A MINIMUM OF 3' WASHED 057 STONE ABOVE AND ON EACH SIDE OF THE PIPE (NOT BELOW) WITH 2' OF CHOKING STONE BETWEEN 057 STONE AND THE SAND S NOFILIEA - CLEAN-OUT AT END OF EA91 UINDE DROWN WEIR 2 SAND FILTER - PLAN WER I WEIR 2 PROVIDE CIFANOUT. AT THE END OF THE UNDE 644 SEK WITH A WATERTIGHT CAP PRECASTREINFORCED CONCRETE SAM Fl TER BY STORMIRAP OR EQUAL 10'I PVC COLLECTION RPE WITH OUTLET TH ROUGTH BOX. PROVIDE WATER -VERDE RUBBER BOOT AT CONNECTION THROUGH BOX. 6'I PERFORATED PVC DROWN PIPE WRAPPED WITH FILTER FABRIC (TYP OF 3) SAND FILTER - SECTION A -A 10' 2' 007 / 08 04WMG STONE - WASHED 3' 057 STONE - WASHED PERFORATED PIPE SAND MEDIA BOTTOM OF SANDFILTER PRECAST REINFORCED CONCRETE SAND FILTER BY STGRMIRAY OR EQUAL PIPE FROM INLET 2 INV: 255.25 SEDIME I HASIN WEIR I -114 36' OPENING FOR ACCESS (TYP OF 3) 5 15 SCALE: 1--g 36' OPENING FOR ACCESS (TTP OF 2) FINISH GRADE VARICS SEE GRADING PLAN cau SEDIMENT BASIN OUTLET FROM STRUCTURE 2 S ebb EOLNEM BASIN PERMANENT 10' POOL - EL 253.50 70' RUBBER BOOT PLANT SIDE WALL OF SEDIMENT 2 -MEM, 10 -MFM. AND BASIN 6' FROM BOAR" FOR IOD -YEAR STORY VOLUMES SEpWENT RED PLANT DEATH INDICATOR. USE BY-PASS THE SANDFILTER SANDFKTER - 24' OEPRI SANDFILTER NOTES: SAND FILTER MEDIA SHALL BE CLEANED, 1. ALL SLOPES DRAINING TO SAID FILTER SHALL BE WASHED, COARSE MASONRY SAND (SUCH STABLT7LTI PER THE NORM CAROLINA STATE EROSION AS ASTMC33) WAIN PARTICLES LE55 THIN AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL 2mm AVERAGE 2mm AYLHM:E DIAMETER. MINIMUM 2' DIA BEFORE SAND IS PLACED IN SAND BED. CUTE 2. PRIOR TO ROUTINE INSPECTION AND MAINTENANCE OF THE SANDFILTER, THESEDIMENT BASIN 5 TO BE DAWN MANHOLE TO FLASH GRADE NG DOWN USIA PUMP TO A DEWATERING BAC.. SEE OPERATIONS MANMORE DETAIL UAL FOR . 0 2.5 5 ID 15 SCALE: 1'=S UNDERDRAIN DETAIL NTS WALL OF SANDFILTER RUBBER BOOT PIPE FROM 10' PVC OUTLET PIPE 10' PVC COLLECTION PIPE TO DAYUGNT -SEE (iRApNG PLAN BOTTOM OF SANDFTLTER WEIR 1 PIPE CONNECTION DETAIL NTS I. aEMM MO GEERS 9—D ? RTMEA D � BW;IDB Tp MA141Y IXSPECf ME PROM BEHBO INE IETEL Ill• IMI FHUM INS,A WEQMNNO NOTA PW XO TO THE. fYNSRORIXN OF 6 WOE LEVEL aPREAOFA ME aVEAOX SMUCMF ON M AMNIA BILA THE LEWD. SPREADER, THE RECEIVING NKA SJgND IOUNc SYMIE/V-ORM MID NTEN ALL SIOWN9 CPEAIEA THW ME HAVE —ARE IOPDWMIY TO PREVOT JAIME U NED III. aA69 'B' WP -MIP 2 -MEM STORY. PION CQCDOMl10H BETaE ENTWXG A SIIHE 15' RCP APE 1. HIE LETEL YRGOEA AILD Ba'fFA SMODU) IM1ERLbIIOZ NOT OE9BY FOQXFFA OF ANY 60.5 BE 01E0(EO POR 90X5 OF EROSAIN NTER ALL WINLiINS 1101E0. NO p131II✓SAII¢ b N10MED IM Nfl19E 01fTP WIIIOUi NFDRO APPROVAL .9 ET41115 E W, to aN IAX4ER Twn THE 2- SF 05' STEM TEM SIOIM. Al# VF ST— TIMI CIRONIE N 2 A LEVEL 5 INOOMB WA BE NSTAUEO 9 6 /5T STORE ME SECTION W /aT STORE 9NOIRB BE O N THE wM NO P TO IA RTW = 4Dn0E 10' PIC oR 6 REYOVEn 1}N 1K SPpEADER to ro CNAIRE MA== IAsWNWELUIN EL W THE DDERwsE .AEA a LLVEV SPiF/ODI w 3. ANT Fa1WA{AN a GULIES. .N EiE NF SOURCE OF COLON ME amucTlAF ALIO aCOAIE A IST ATONE —R,O sHOU.OPF .` ,ssEO 90NE4 OF EROSON. 1' WOE COAL. RAi IS U61T JKL Slquul BE I40RESSID UUO`A S1FiOFR MRO R M IPRIGIIDN a EROSpN NAMIPOL 3. OF POs t1CT if MI T S OX XD51IOF ELLWTIPI 2585 Wl OR PE�RADiNL P XECESSARf. Sat F P0PI— OR COMPACT NFA TO L, O< PLAN srANDN+o PRonoP rEsr uN¢HHGM IE�EL 9#IDErt IACAnON. A. CGNS,RUCT FORMS USNG PLYNOoo A10 STARES. I C14R AM PE-CIECR TIME THE TOP OF THE IOIW6 AIF JF R 6 CAIIGa THAT THE LEVEL SIVFAOEP 6 IML. OURLT EIATM BLEND sWME / V-OIOI � lfLYl sWFADaR FpYa aHaan BE LDGIFD SAIpXHER LIYm WIM QAR 'W TAH X/P HIE OONIF9DPE ENO OE THE dGM1FD MFA 9PRFAOER ID ). IOP OF FpNVi' SCUD BE APPRaMAID,Y SMGKIN THIN THE NXIOININp 51.69 9AFAlf TOFII6LOPE ro Aunw aNF1lsE iLNw ro Otl.YR Aro THE MNTTA. I 1.18 Lem uTOtQf/a7SWINEn USBW CONCRETE, pFATE A sYODTH �(ETIEEXIBE uNOER A'. SONE-IUWN DJITN AT EOXn 91RFACE. tlf-NAgY otow — SECTION LEVELSPREADER CALL BEFORE YOU 0101 NORTH CAROLANA LAW REQUIRES NOTIFICATION OF THE UNDERGROUND FACILITY DIMMER NOT LESS THAN TWO (2) CVT NO MORE THAN TEN HOl RgNO DAYS PRIOR TO EXCAVATION OR RDewLrtaN TH CARO I 11 www.nc811.org 14800-632-4949 NoM Caroikm One4all Confor, Inc. REVISIONS No. DATE DESCRIPTION REV. BY APPROVED FOR PERMITTING NOT FOR CONSTRUCTION I► . h m �g p� i $e COORDINATOR: DRABG BY7-1: HK BY: BPP Z W 2 W 0 Z S� Z ZQJ COQ itU LLJ Y JOit ('-1O ZOfz QOw v Rr Z 24X36 10 MAY 2018 7963.0072 DETAILS FA3.0 PIPE FROM STRUCTURE 2 WEIR 1 MANHOLE TO FLASH GRADE MANHOLE TO FINISH OWE STEPS AT MANHOLE PIPE FROM ROOF DROWN NV- 11i1.00 T ID. fE :fi 1 ._ • SEDIMENT BASIN WEIR 2 SANDFILTER STEPS AT MANHOLE CUTLET PPE SAND FILTER N.T.S. I. aEMM MO GEERS 9—D ? RTMEA D � BW;IDB Tp MA141Y IXSPECf ME PROM BEHBO INE IETEL Ill• IMI FHUM INS,A WEQMNNO NOTA PW XO TO THE. fYNSRORIXN OF 6 WOE LEVEL aPREAOFA ME aVEAOX SMUCMF ON M AMNIA BILA THE LEWD. SPREADER, THE RECEIVING NKA SJgND IOUNc SYMIE/V-ORM MID NTEN ALL SIOWN9 CPEAIEA THW ME HAVE —ARE IOPDWMIY TO PREVOT JAIME U NED III. aA69 'B' WP -MIP 2 -MEM STORY. PION CQCDOMl10H BETaE ENTWXG A SIIHE 15' RCP APE 1. HIE LETEL YRGOEA AILD Ba'fFA SMODU) IM1ERLbIIOZ NOT OE9BY FOQXFFA OF ANY 60.5 BE 01E0(EO POR 90X5 OF EROSAIN NTER ALL WINLiINS 1101E0. NO p131II✓SAII¢ b N10MED IM Nfl19E 01fTP WIIIOUi NFDRO APPROVAL .9 ET41115 E W, to aN IAX4ER Twn THE 2- SF 05' STEM TEM SIOIM. Al# VF ST— TIMI CIRONIE N 2 A LEVEL 5 INOOMB WA BE NSTAUEO 9 6 /5T STORE ME SECTION W /aT STORE 9NOIRB BE O N THE wM NO P TO IA RTW = 4Dn0E 10' PIC oR 6 REYOVEn 1}N 1K SPpEADER to ro CNAIRE MA== IAsWNWELUIN EL W THE DDERwsE .AEA a LLVEV SPiF/ODI w 3. ANT Fa1WA{AN a GULIES. .N EiE NF SOURCE OF COLON ME amucTlAF ALIO aCOAIE A IST ATONE —R,O sHOU.OPF .` ,ssEO 90NE4 OF EROSON. 1' WOE COAL. RAi IS U61T JKL Slquul BE I40RESSID UUO`A S1FiOFR MRO R M IPRIGIIDN a EROSpN NAMIPOL 3. OF POs t1CT if MI T S OX XD51IOF ELLWTIPI 2585 Wl OR PE�RADiNL P XECESSARf. Sat F P0PI— OR COMPACT NFA TO L, O< PLAN srANDN+o PRonoP rEsr uN¢HHGM IE�EL 9#IDErt IACAnON. A. CGNS,RUCT FORMS USNG PLYNOoo A10 STARES. I C14R AM PE-CIECR TIME THE TOP OF THE IOIW6 AIF JF R 6 CAIIGa THAT THE LEVEL SIVFAOEP 6 IML. OURLT EIATM BLEND sWME / V-OIOI � lfLYl sWFADaR FpYa aHaan BE LDGIFD SAIpXHER LIYm WIM QAR 'W TAH X/P HIE OONIF9DPE ENO OE THE dGM1FD MFA 9PRFAOER ID ). IOP OF FpNVi' SCUD BE APPRaMAID,Y SMGKIN THIN THE NXIOININp 51.69 9AFAlf TOFII6LOPE ro Aunw aNF1lsE iLNw ro Otl.YR Aro THE MNTTA. I 1.18 Lem uTOtQf/a7SWINEn USBW CONCRETE, pFATE A sYODTH �(ETIEEXIBE uNOER A'. SONE-IUWN DJITN AT EOXn 91RFACE. tlf-NAgY otow — SECTION LEVELSPREADER CALL BEFORE YOU 0101 NORTH CAROLANA LAW REQUIRES NOTIFICATION OF THE UNDERGROUND FACILITY DIMMER NOT LESS THAN TWO (2) CVT NO MORE THAN TEN HOl RgNO DAYS PRIOR TO EXCAVATION OR RDewLrtaN TH CARO I 11 www.nc811.org 14800-632-4949 NoM Caroikm One4all Confor, Inc. REVISIONS No. DATE DESCRIPTION REV. BY APPROVED FOR PERMITTING NOT FOR CONSTRUCTION I► . h m �g p� i $e COORDINATOR: DRABG BY7-1: HK BY: BPP Z W 2 W 0 Z S� Z ZQJ COQ itU LLJ Y JOit ('-1O ZOfz QOw v Rr Z 24X36 10 MAY 2018 7963.0072 DETAILS FA3.0 1, MICHAEL A. MOSS, CERTIFY THAT THIS PLAT NOTARY PUBLIC WAS DRAWN UNDER MY SUPERVISION FROM AN MY COMMISSION EXPIRES: ACTUAL SURVEY MADE UNDER MY SUPERVISION; MAKE COUNTY.2 THAT THE SOURCE OF INFORMATION FOR THE SURVEY IS SHOWN HEREON; THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED; THAT THE �p.E.. w������� X10 CAR, �Rp RATIO OF PRECISION IS GREATER THAN 1:10.000; THAT THIS PLAT WAS PREPARED IN ACCORDANCE Q'(N ,y{g���yp} E,$$%�-.4y '�` 0 WITH G.S. 47-30 AS AMENDED: AND THAT THIS MAP+ .9 'fQ MEETS THE REQUIREMENTS OF THE STANDARDS OF l SEAL i PRACTICE FOR LAND SURVEYING IN NORTH CAROLINA = L-3794 J - NCAC (21 56. 1600). WITNESS MY ORIGINAL SIGNATURE, •.(� Q•: REGISTRATION NUMBER AND SEAL ��j'-,'Lb �P �z THIS •3� DAY .2017. su ���jCojj"'- PROFESSIONAL LAND SURVEYOR (L-3794) THIS CERTIFIES AND WARRANTS THAT THE UNDERSIGNED IS (ARE) THE SOLE OWNER(S) OF THE PROPERTY SHOWN ON THE MAP OR PLAT AND ANY ACCOMPANYING SHEETS HAVING ACQUIRED THE PROPERTY IN FEE SIMPLE BY DEED(S) RECORDED IN THE COUNTY REGISTER OF DEEDS OFFICE WHERE THE PROPERTY IS LOCATED AND AS SUCH HAS (HAVE) THE RIGHT TO CONVEY THE PROPERTY IN FEE SIMPLE. BOOK NO.: 15779 PAGE NO.: 1891 SIGNATURES) & TITLE/POSITION OF PROPERTY OWNER(S): �I IPt.I ftf.-k'�t c � s�� L li✓..G [.99..�jN�� STATE OF NORTH CAROLINA COUNTY OF WAKE I CERTIFY THAT THE FOLLOWING PERSON(S) PERSONALLY APPEARED BEFORE ME THIS DAY, EACH ACKNOWLEDGING TO ME THAT HE OR SHE VOLUNTARILY SIGNED THE FOREGOING DOCUMENT FOR THE PURPOSE STgTED THEREIN AND IN THE CAPACITY INDICATED: �' BMJGG L 6tlitt7i411 s DATE: Qef0,0A4 i - S'y . 2017 r r f l I I r 1 � � r 1 y{ / r r 7— mr MAP \ ! ! z v \ � r IS N DEED BOON 14196. PPAG 9 50 BOON OF MAPS 1982. PICS 593 PM/ 1727.11 -SS -1879 DOSTING 1 -STORY max. I _ I I I � / i J Is ANNUOL CHANCE FL000PUN- Srt'Mm FROM WNQ C"m Go FROM PANEL 372D1727041, EFFECT1vE DATE MAY 2, 2008 / PALEIGH CURL LLC DEm L7001( 8005, PAGE 194 BOOK aF IMPS RIVE, PAGE 1953 EFFR F TNM/1727,10-45-1154 ri4, •.w .\ X77 TT t WELLMO1ISE FO VAULT O EP -2 MTEL. I It / 17 •nT3 � `- '\ a s 34=7sq�ft. / PIP0.786 AC. g 57.4' 3 GRAVEL t oads ) r 10 \ l y pp 31,2!11 `"L 0.718 (1 AM AO.) NELLIIOIISE NEW LOT UNE / 40' CRY 01 RALi / SANITARY SEW E45DOU &M. 198& PAGE 149 r 4e r\ A \-_ r --- _� / LINE TABLE UNE . BEARING DISTANCE L -t S 71'48 32' E 4.23 ZONE AE 7� FROM GIS 727000, 2. 2005 FORIER LOT UK l / IERFBY REmovw camING METAL / GRAVEL / ORAVEL / . `15.6' Plattedp MUSE *PER RIPARIAN DUFFER L\ r `EGm,. _ �tV PERRY CIEFX/LREDW LAKE CURVE TABLE CURVE I ARC LENGTH I RADIUS I CHORD LENGTH 1 CHORD BEARING C-1 1 38.84 362.33 38.83 S 7,r52-47- E C-2 76.89' 1 382.33 76.74 N W 02 15 W CAWTHORNE, MOSS & PANCIERA, M IMEIGH SO CLIA, LLC 0® 800K 8005• PAGE 194 B00N W MAPS 1997, PARE 1983 Mq 1727.10-45-1154 I, MICHAEL A. MOSS, PROFESSIONAL LAND SURVEYOR 140. L-3794, CERTIFY THAT THIS PLAT 15 OF A SURVEY OF ANOTHER CATEGORY, SUCH AS THE RECOMBINATION OF EXISTING PARCELS, A COURT ORDERED SURVEY, OR OTHERS EXC EPTI ON TO THE DEFINITION OF SUBDIVISION. MICHAEL A. MOSS, PROFESSIONAL LAND SURVEYOR NO. L-3794 P.C. PROFESSIONAL LAND SURVEYORS, C-1525. 333 S. N W1LBlON CW& LLA 0BDA( BOOS, PACE 194 80011R OF MMS 1997, PACE 1953 P9y 1727.10-45-1754 or map I not a subdivision, but a recombirlation of previously roP". 9M mep V fftutmy RquImrr*m fm recoramg _ THIS PLAT IS NOT 40, BE RECORDED DAY OF ONE (1) COPY TO BE RETAINED FOR THE CITY. THIS PLAT IS _JN ITT OF THE CITY MATS. A-1 /h FLOOD �P� WN ORDINANCE 4 f [ rmM PANEL 3 7 111 17 2200-1 ] OTHER ITROL coNER. APPROVED BY: N LL3 121!3/!7 r75381A0 172542&90 AREAS IDENTIFIED AS MEUSE RIVER RIPARIAN BUFFER SHALL BE MAINTAINED IN PERPETUITY IN THEIR NATURAL OR MITIGATED CONDITION. NO PERSON OR ENTITY SHALL FILL. GRADE, EXCAVATE, OR PERFORM ANY OTHER LAND -DISTURBING ACTIVITIES; NOR CUT, REMOVE, OR HARM ANY VEGETATION; NOR CONSTRUCT ANY STRUCTURES NOR ADD ANY ADDITIONAL IMPERMUOS SURFACE, NOR ALLOW ANIMAL GRAZING OR WATERING OR ANY OTHER AGRICULTURAL USE ON SUCH PROTECTED AREAS WITHOUT WRITTEN AUTHORIZATION OF VICINITY MAP AREA COMPUTED BY COORPKAIE IETpD. TETE B No MOW MOMIIIE rr MANN Z00O w TNS PROPERTY. - TNS PROPEMTY MAY BE SIAHIDCT 10 IEUY N%V RPARIAN BLWM HUES. CALL N.C. DIWSI0N OF WATER CLMUTY TO YEREY (919-7N-4200). THIS SITE IS PARTWAY WITHIN A FLOOD HAZARD AREA PER FLOOD INSURANCE RATE MAP NUMBER 3720172700 J, EFFECTIVE DATE MAY 2. 2006. LEGEND: EIP - EXISTING IRON PIPE LPK - EXISTING PK NAIL NIP - NEW IRON PIPE SET R/W - RIGHT OF WAY CAN - CABLE TV BOX EB - ELECTRIC BOX TEL - TELEPHONE PEDESTAL PP - POWER POLE OHL - OVERHEAD UNE LP - LIGHT POLE WM - WATER METER WV - WATER VALVE CO - SEWER CLEAN-OUT UNE TYPE LEGEND PROPERTY LINE - LRE SURVEYED — NWT -W -WAY — AD.OEaNO L17E - UE NOT RAMPED —_ . -- - OEEINIEIID LIRE — — — E IDWNTLDING GN — — eL91EM /�ARYAZg�rEM RECOMBINATION SURVEY FOR LOTS 16 & 17 RALEIGH INDUSTRIAL PARK OWNER: SAL REAL ESTATE, LLC REF: D.B. 15779, PG. 1891 REF: B.M. 1982, PG. 593 NEUSE TOWNSHIP CITY OF RALEIGH WAKE COUNTY, NORTH CAROLINA 40 20 0 40 80 SCALE 1"=40' THE DIVISION OF WATER QUALITY (DWQ) OR NOVEMBER 10, 2017 COMPLIANCE WITH THE RIPARIAN BUFFER In PROTECTION RULES (15A NCAC 28 .0233 OR ZONED: n SHOD 2 .0259). THIS COVENANT IS TO RUN NTH THE PIN # 1727.11-55-3524 LAND, AND SHALL BE BINDING ON THE OWNER, AND ALL PARTIES CLAIMING UNDER IT. PIN # 1727.11-55-4531 CASE# R-147-2017 RA006'�t6 TRANSACTION: 535840 WHITE STREET, P.O. BOX 1253. WAKE FOREST N.C.. 27586. (919) 556-3148 NOTARY PUBLIC PRINTED NAME: 1 MY COMMISSION EXPIRES: .3, OW MAKE COUNTY.2 0 EiL) CHARLES P.GILLIAN ........ REGISTER OF DEEDS r•t PRESENTED & RECORDED ON 12115/2417 13:1S:37 mfr: ®06� :*E DOOK:3N2017 PAGE:/2543 ���jCojj"'- r r f l I I r 1 � � r 1 y{ / r r 7— mr MAP \ ! ! z v \ � r IS N DEED BOON 14196. PPAG 9 50 BOON OF MAPS 1982. PICS 593 PM/ 1727.11 -SS -1879 DOSTING 1 -STORY max. I _ I I I � / i J Is ANNUOL CHANCE FL000PUN- Srt'Mm FROM WNQ C"m Go FROM PANEL 372D1727041, EFFECT1vE DATE MAY 2, 2008 / PALEIGH CURL LLC DEm L7001( 8005, PAGE 194 BOOK aF IMPS RIVE, PAGE 1953 EFFR F TNM/1727,10-45-1154 ri4, •.w .\ X77 TT t WELLMO1ISE FO VAULT O EP -2 MTEL. I It / 17 •nT3 � `- '\ a s 34=7sq�ft. / PIP0.786 AC. g 57.4' 3 GRAVEL t oads ) r 10 \ l y pp 31,2!11 `"L 0.718 (1 AM AO.) NELLIIOIISE NEW LOT UNE / 40' CRY 01 RALi / SANITARY SEW E45DOU &M. 198& PAGE 149 r 4e r\ A \-_ r --- _� / LINE TABLE UNE . BEARING DISTANCE L -t S 71'48 32' E 4.23 ZONE AE 7� FROM GIS 727000, 2. 2005 FORIER LOT UK l / IERFBY REmovw camING METAL / GRAVEL / ORAVEL / . `15.6' Plattedp MUSE *PER RIPARIAN DUFFER L\ r `EGm,. _ �tV PERRY CIEFX/LREDW LAKE CURVE TABLE CURVE I ARC LENGTH I RADIUS I CHORD LENGTH 1 CHORD BEARING C-1 1 38.84 362.33 38.83 S 7,r52-47- E C-2 76.89' 1 382.33 76.74 N W 02 15 W CAWTHORNE, MOSS & PANCIERA, M IMEIGH SO CLIA, LLC 0® 800K 8005• PAGE 194 B00N W MAPS 1997, PARE 1983 Mq 1727.10-45-1154 I, MICHAEL A. MOSS, PROFESSIONAL LAND SURVEYOR 140. L-3794, CERTIFY THAT THIS PLAT 15 OF A SURVEY OF ANOTHER CATEGORY, SUCH AS THE RECOMBINATION OF EXISTING PARCELS, A COURT ORDERED SURVEY, OR OTHERS EXC EPTI ON TO THE DEFINITION OF SUBDIVISION. MICHAEL A. MOSS, PROFESSIONAL LAND SURVEYOR NO. L-3794 P.C. PROFESSIONAL LAND SURVEYORS, C-1525. 333 S. N W1LBlON CW& LLA 0BDA( BOOS, PACE 194 80011R OF MMS 1997, PACE 1953 P9y 1727.10-45-1754 or map I not a subdivision, but a recombirlation of previously roP". 9M mep V fftutmy RquImrr*m fm recoramg _ THIS PLAT IS NOT 40, BE RECORDED DAY OF ONE (1) COPY TO BE RETAINED FOR THE CITY. THIS PLAT IS _JN ITT OF THE CITY MATS. A-1 /h FLOOD �P� WN ORDINANCE 4 f [ rmM PANEL 3 7 111 17 2200-1 ] OTHER ITROL coNER. APPROVED BY: N LL3 121!3/!7 r75381A0 172542&90 AREAS IDENTIFIED AS MEUSE RIVER RIPARIAN BUFFER SHALL BE MAINTAINED IN PERPETUITY IN THEIR NATURAL OR MITIGATED CONDITION. NO PERSON OR ENTITY SHALL FILL. GRADE, EXCAVATE, OR PERFORM ANY OTHER LAND -DISTURBING ACTIVITIES; NOR CUT, REMOVE, OR HARM ANY VEGETATION; NOR CONSTRUCT ANY STRUCTURES NOR ADD ANY ADDITIONAL IMPERMUOS SURFACE, NOR ALLOW ANIMAL GRAZING OR WATERING OR ANY OTHER AGRICULTURAL USE ON SUCH PROTECTED AREAS WITHOUT WRITTEN AUTHORIZATION OF VICINITY MAP AREA COMPUTED BY COORPKAIE IETpD. TETE B No MOW MOMIIIE rr MANN Z00O w TNS PROPERTY. - TNS PROPEMTY MAY BE SIAHIDCT 10 IEUY N%V RPARIAN BLWM HUES. CALL N.C. DIWSI0N OF WATER CLMUTY TO YEREY (919-7N-4200). THIS SITE IS PARTWAY WITHIN A FLOOD HAZARD AREA PER FLOOD INSURANCE RATE MAP NUMBER 3720172700 J, EFFECTIVE DATE MAY 2. 2006. LEGEND: EIP - EXISTING IRON PIPE LPK - EXISTING PK NAIL NIP - NEW IRON PIPE SET R/W - RIGHT OF WAY CAN - CABLE TV BOX EB - ELECTRIC BOX TEL - TELEPHONE PEDESTAL PP - POWER POLE OHL - OVERHEAD UNE LP - LIGHT POLE WM - WATER METER WV - WATER VALVE CO - SEWER CLEAN-OUT UNE TYPE LEGEND PROPERTY LINE - LRE SURVEYED — NWT -W -WAY — AD.OEaNO L17E - UE NOT RAMPED —_ . -- - OEEINIEIID LIRE — — — E IDWNTLDING GN — — eL91EM /�ARYAZg�rEM RECOMBINATION SURVEY FOR LOTS 16 & 17 RALEIGH INDUSTRIAL PARK OWNER: SAL REAL ESTATE, LLC REF: D.B. 15779, PG. 1891 REF: B.M. 1982, PG. 593 NEUSE TOWNSHIP CITY OF RALEIGH WAKE COUNTY, NORTH CAROLINA 40 20 0 40 80 SCALE 1"=40' THE DIVISION OF WATER QUALITY (DWQ) OR NOVEMBER 10, 2017 COMPLIANCE WITH THE RIPARIAN BUFFER In PROTECTION RULES (15A NCAC 28 .0233 OR ZONED: n SHOD 2 .0259). THIS COVENANT IS TO RUN NTH THE PIN # 1727.11-55-3524 LAND, AND SHALL BE BINDING ON THE OWNER, AND ALL PARTIES CLAIMING UNDER IT. PIN # 1727.11-55-4531 CASE# R-147-2017 RA006'�t6 TRANSACTION: 535840 WHITE STREET, P.O. BOX 1253. WAKE FOREST N.C.. 27586. (919) 556-3148