Loading...
HomeMy WebLinkAboutNC0066362_Inspection_20180521EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0066362 18/05/09 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Benson Apartments 161 Brookside Camp Rd Hendersonville NC 28792 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 18/05/09 16/03/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 11:00AM 18/05/09 20/12/31 Name, Address of Responsible Official/Title/Phone and Fax Number Nathan D Benson,PO Box 1090 Mountain Home NC 287581090//828-693-5493/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date G. Landon Davidson ARO WQ//828-296-4500/ Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 342AF6FC-2AC0-4108-97AB-A6DC713B77A7 5/21/2018 5/21/2018 NPDES yr/mo/day 18/05/09 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 5/9/2018, Landon Davidson and I met with Nathan Benson (owner), Colleen, Mark Jones (ORC), and Daniel Jones for a compliance evaluation inspection at the Benson Apartments WWTP. This is a class II activated sludge wastewater facility. The facility has a history of noncompliance with permit limits and $12,000 in enforcements in the past 10 years. Mark Jones has very recently taken responsibility for operation of the facility (May 1, 2018). Here are the conditions of the facility according to Mark on his first visit of the facility: 1. One of the two aeration basin diffusers was not in operation. 2. The D.O. in the aeration basin was <1 mg/L. 3. One of the two blowers did not have any pulleys or belts on it. 4. The pretreatment septic tank contained 70% solids. Mark said it had never been pumped. Mr. Benson said the previous ORC was not aware that the septic tank existed. 5. The aeration basin contained 90% settleable solids. 6. Rusted gratings and structure. One pipe was leaking between the clarifier trough and the chlorinator. 7. Broken timer on the one operating blower. Already Mark has taken the following actions: 1. Pumped solids out of the aeration basin. It is now at 35% settleable solids in one hour. 2. Pumped out the septic tank. 3. Repaired the timer on the blower. 4. Repaired the diffuser that was not operating. Measured D.O. is now 2.4 mg/L. 5. Added pulleys to the blower not in operation in case of need for immediate use. I took effluent samples for TSS, BOD, and fecal coliform. Results are as follows: Fecal- 30 col/100ml, BOD- 12mg/L, TSS- 150 mg/L. TSS was the only parameter that exceeded permit limits. Please continue making improvements to the facility and operations to get this parameter into compliance. NC0066362 17 (Cont.) Page#2 DocuSign Envelope ID: 342AF6FC-2AC0-4108-97AB-A6DC713B77A7 Permit:NC0066362 Inspection Date:05/09/2018 Owner - Facility: Inspection Type: Benson Apartments Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? We could not find the outfall.Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) Foam covered probably 40% of the surface. I expect this to reduce from the improved plant operation. Comment: Page#3 DocuSign Envelope ID: 342AF6FC-2AC0-4108-97AB-A6DC713B77A7 Permit:NC0066362 Inspection Date:05/09/2018 Owner - Facility: Inspection Type: Benson Apartments Compliance Evaluation Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?1 Comment: Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? There was some sludge in the clarifier. Less than a foot according to Mark.Comment: Page#4 DocuSign Envelope ID: 342AF6FC-2AC0-4108-97AB-A6DC713B77A7 Permit:NC0066362 Inspection Date:05/09/2018 Owner - Facility: Inspection Type: Benson Apartments Compliance Evaluation Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?1 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? There was some sludge in the contact chamber.Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Page#5 DocuSign Envelope ID: 342AF6FC-2AC0-4108-97AB-A6DC713B77A7