Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0023086_Site Plans_20180316
U) w m 0 a z 0 U) a M 0 N 0 0 w m co 0 0 3 U w 0 co co 0 0 0 N (n 3 Q LIGHTING MOUNTING AS NOTED SYMBOL DESCRIPTION ® CEILING MOUNTED FLUORESCENT FIXTURE; LETTER INSIDE OR BESIDE DENOTES FIXTURE TYPE ® CEILING MOUNTED FLUORESCENT LIGHTING FIXTURE, WIRED FOR NORMAL/STANDBY POWER OPERATION; LETTER INSIDE OR BESIDE FIXTURE DENOTES FIXTURE TYPE WALL MOUNTED FLUORESCENT FIXTURE O CEILING MOUNTED INCANDESCENT OR H.I.D. FIXTURE 1-0 WALL MOUNTED INCANDESCENT OR H.I.D. FIXTURE 0-p FQ POLE STANDARD LIGHT FIXTURE UNIT - SINGLE ARM 0-Q ❑f❑ 0-0-0 POLE STANDARD LIGHT FIXTURE UNIT -DOUBLE ARM �d ® POLE LANTERN TYPE LIGHT FIXTURE UNIT ® EXIT SIGN Z EXIT SIGN (DOUBLE FACE) EXIT SIGN WITH DIRECTIONAL ARROW EMERGENCY BATTERY PACK UNIT Ali I REMOTE HEAD FOR EMERGENCY BATTERY PACK UNIT SWITCHING SYMBOL MOUNTING DESCRIPTION S 48"AFF SWITCH, SINGLE POLE S2 48"AFF SWITCH, DOUBLE POLE $3 48"AFF SWITCH, 3 -WAY $4 48"AFF SWITCH, 4 -WAY S 48"AFF SWITCH, DIMMER $r 48"AFF SWITCH WITH PILOT LIGHT $ 48"AFF SWITCH, MANUAL MOTOR STARTER, RATING AND THERMAL ,; EXPLOSION OVERLOADS TO MATCH MOTOR NAME PLATE DATA S, 48' AFF SWITCH, MANUAL MOTOR STARTER WITH IVORY, INTRUSION ALARM ILLUMINATED HANDLE $ 48"AFF SWITCH, MANUAL MOTOR STARTER WITH ALARM CONTROL PANEL PILOT LIGHT $ 48"AFF MANUAL MOTOR STARTER SWITCH FRACTIONAL DUPLEX RECEPTACLE- FLOOR BOX -FLUSH - SPD HORSEPOWER O AS NOTED PHOTOELECTRIC CONTROL COMBINATION DUPLEX RECEPTACLE (SPD)/VOICE OUTLET 48"AFF LIGHTING CONTACTOR R1 DESIGNATION FOU- - - - UNDERGROUND FIBER OPTIC BOX -FLUSH LIGHTING CONTACTOR REMOTE PUSH-BUTTON LC -1 COMBINATION DISCONNECT SWITCH/MOTOR STARTER "ON-OFF" CONTROL PROCESS REPRESENTS LIGHTING CONTACTOR BEING CONTROLLED DS AS NOTED DOOR SWITCH MC AS NOTED MOTION CONTROL OCEILING JUNCTION BOX MOTION SENSOR OS CEILING OCCUPATION SENSOR INTRUSION ALARM SYSTEM SYMBOL MOUNTING DESCRIPTION DJ AS NOTED INTRUSION ALARM MAGNETIC DOOR CONTACTS K❑ 48"AFF INTRUSION ALARM KEY PAD M❑ AS NOTED INTRUSION ALARM MOTION DETECTOR DJ AS NOTED INTRUSION ALARM MAGNETIC DOOR CONTACTS, EXP DUPLEX RECEPTACLE -FLUSH -WITH GROUND FAULT CIRCUIT EXPLOSION PROOF INTERRUPTER LJ AS NOTED INTRUSION ALARM BELL IACP 48"AFF INTRUSION ALARM CONTROL PANEL TELECOMMUNICATION SYMBOL MOUNTING DESCRIPTION AD AS NOTED AUTO DIALER # 36"AFF PHONE PORT (# = NUMBER OF VOICE PORTS) �Y # \ �: DENOTES MOUNTED �L 36"AFF DATA PORT (# = NUMBER OF DATA PORTS) # # 36"AFF COMBINATION DATA/PHONE PORT SPECIAL PURPOSE OUTLET (SIZE INDICATED ON PLANS) T (# = NUMBER OF DATA PORTS/VOICE PORTS) ❑v # FLOOR PHONE PORT- FLOOR BOX -FLUSH DUPLEX RECEPTACLE -FLUSH -WITH GROUND FAULT CIRCUIT FO (# = NUMBER OF DATA PORTS/VOICE PORTS) HVAC SYMBOL MOUNTING DESCRIPTION MM AS NOTED AS NOTED OT 48"AFF MOTOR OPERATED DAMPER UNIT HEATER THERMOSTAT PANELBOARDS SYMBOL MOUNTING DESCRIPTION TOP BREAKER 6'-0"AFF = TOP BREAKER 6'-0' AFF O --- --- NEW PANELBOARD - SURFACE MOUNTED NEW PANELBOARD - FLUSH MOUNTED EXISTING PANELBOARD - SURFACE MOUNTED EXISTING PANELBOARD - FLUSH MOUNTED POWER SYMBOL MOUNTING DESCRIPTION „ CDUPLEX RECEPTACLE, 20A RATED WP 36 AFF E FAA FOOTNOTE DELINEATES SPECIFIC DEVICE \ �: DENOTES MOUNTED 6" ABOVE COUNTERTOP PE REQUIREMENT - SEE ABBREVIATIONS If 36"AFF SPECIAL PURPOSE OUTLET (SIZE INDICATED ON PLANS) T 36"AFF SINGLE RECEPTACLE, 20A RATED OVERHEAD TELEPHONE SERVICE 36"AFF DUPLEX RECEPTACLE -FLUSH -WITH GROUND FAULT CIRCUIT FO OVERHEAD FIBER OPTIC INTERRUPTER FIRE ALARM AUDIBLE ALARM, EXPLOSION PROOF WALL MOUNTED AT 36"AFF DOUBLE DUPLEX RECEPTACLE, 20A RATED - - - - 18"AFF DUPLEX RECEPTACLE -FLUSH - SURGE -PROTECTIVE ]i - - - - DEVICE (SPD) - - - FLOOR DUPLEX RECEPTACLE- FLOOR BOX -FLUSH Llsfl FLOOR DUPLEX RECEPTACLE- FLOOR BOX -FLUSH - SPD SEU - SURGE -PROTECTIVE DEVICE (SPD) ® FLOOR COMBINATION DUPLEX RECEPTACLE (SPD)/VOICE OUTLET SPD UNDERGROUND TELEPHONE SERVICE PORT- (# DESIGNATES NUMBER OF VOICE PORTS) - FLOOR FOU- - - - UNDERGROUND FIBER OPTIC BOX -FLUSH `® 48"AFF COMBINATION DISCONNECT SWITCH/MOTOR STARTER MSE PROCESS CONDUIT - IN WALL, CEILING OR EXPOSED XX EXISTING TO REMAIN DESIGNATION CONDUIT WITH IDENTIFIER AS NOTED MOTOR (HORSEPOWER INDICATED ON PLANS) pJ AS NOTED JUNCTION BOX FT FU TRANSFORMER T-1 FIBERGLASS REINFORCED EPDXY DESIGNATION CM AS NOTED CIRCUIT MONITOR VR 2 AS NOTED VOLTAGE REGULATOR SPD AS NOTED SURGE -PROTECTIVE DEVICE MINIMUM 48"AFF EMERGENCY POWER SHUT-OFF SWITCH ❑H 48"AFF LOCKABLE ON -OFF -AUTO SELECTOR SWITCH W/RED MOTOR OPERATED DAMPER IN-LINE HOME RUN INDICATOR LIGHT EIJ 48"AFF DISCONNECT SWITCH DSA UT N/A CIRCUIT NUMBER UV DESIGNATION NORMALLY CLOSED 480V NEMA 5480V 0KVAR TRANSFORMER NID SIZE VS 120V NORMALLY OPEN W NO. VOLTAGES WP RADIATION SHIELDED ISOLATION TYPE TRANSFORMER © EQUIPMENT CONNECTION COMBINATION MOTOR CONTROLLER TYPICAL ANNOTATION ODRAWING KEYNOTE a DEMOLITION KEYNOTE Q REVISION TAG DREVISION CLOUD AAA INSTRUMENTATION TAG CGMDP-701 PROCESS EQUIPMENT TAG SF HVAC EQUIPMENT TAG HW1 4X AREA NEMA DESIGNATION TAG PROCESS & INSTRUMENTATION LEGEND CIRCUIT TAG DESCRIPTIONS: PANEL � CIRCUIT NUMBER IN PANEL SBRCP300-15: 8 (4) #14 3/4 CONDUIT SIZE SIZE OF CONDUCTORS # OF SPARE CONDUCTORS # OF ACTIVE CONDUCTORS ADD FOR TOTAL # OF CONDUCTORS (EX. 8 + 4 = 12 TOTAL CONDUCTORS) SAFETY SWITCH DESIGNATOR 240/30/3/15 D.E./1 VOLTAGE AMPERAGE #POLES FUSE SIZE AND TYPE NF -NON-FUSED NEMA RATING SAFETY SWITCH C:Ij NOTES: 1. INSTALL ALL FUSES SO THAT LABELS ARE RIGHT -SIDE UP AND FACING OUTWARD. 2. INSTALL OXIDATION INHIBITING COMPOUND SUCH AS PENETROX IN ALL FUSE CLIPS OF SAFETY SWITCHES LOCATED OUTDOORS OR IN WET ENVIRONMENTS. CONDUIT FEEDERS AND BRANCH CIRCUITS SYMBOL MOUNTING DESCRIPTION U.O.N. FACP DESCRIPTION E FAA E OVERHEAD ELECTRIC SERVICE PE AS NOTED PE OVERHEAD PRIMARY ELECTRIC SERVICE SE A.F.F. OR 6" BELOW CEILING; WHICHEVER IS LOWER SE OVERHEAD SECONDARY ELECTRIC SERVICE T O T OVERHEAD TELEPHONE SERVICE FO CEILING FO OVERHEAD FIBER OPTIC — CTV FIRE ALARM AUDIBLE ALARM, EXPLOSION PROOF WALL MOUNTED AT CTV — OVERHEAD TELEVISION SERVICE - - - - - - - - - CONDUIT - EMBEDDED IN FLOOR OR EARTH - - - - EU- - - - UNDERGROUND ELECTRIC SERVICE - - - - PEU - - - - UNDERGROUND PRIMARY ELECTRIC SERVICE - - - - SEU - - - - UNDERGROUND SECONDARY ELECTRIC SERVICE ----TU---- TAGGING DPDT UNDERGROUND TELEPHONE SERVICE - - - - FOU- - - - UNDERGROUND FIBER OPTIC - - - - CTVU - - - - UNDERGROUND TELEVISION SERVICE 48"AFF FIRE SUPPRESSION SYSTEM PRESSURE SWITCH PROCESS CONDUIT - IN WALL, CEILING OR EXPOSED XX EXISTING TO REMAIN XX CONDUIT WITH IDENTIFIER G EACH WAY G GROUND GRID EXH EXHAUST FAN FU CONDUIT TURNED UP FRE FIBERGLASS REINFORCED EPDXY G.C. CONDUIT TURNED DOWN GEN GENERATOR MOTOR CONTROL CENTER CONDUIT CAPPED MFR MANUFACTURER UE BRANCH CIRCUIT WIRING MINIMUM UH Now CIRCUIT HOME RUN UL M.O.D. MOTOR OPERATED DAMPER IN-LINE HOME RUN MS 1 UE MTD. MOUNTED UT N/A CIRCUIT NUMBER E E EMERGENCY ONLY CIRCUIT NE NE NORMAL EMERGENCY CIRCUIT DEVICES ON SAME CIRCUIT, SEPARATELY CONTROLLED G>--c)ELECTRIC FEEDER LEGEND INDICATION FIRE ALARM SYSTEM SYMBOL MOUNTING DESCRIPTION U.O.N. FACP 48"AFF FIRE ALARM CONTROL PANEL FAA AS NOTED FIRE ALARM ANNUNCIATOR A❑ AS NOTED FIRE ALARM AUDIBLE/VISIBLE SIGNAL WALL MOUNTED AT 6'-8" MIXER B A.F.F. OR 6" BELOW CEILING; WHICHEVER IS LOWER F❑ 48"AFF FIRE ALARM MANUAL PULL STATION O CEILING FIRE ALARM SMOKE DETECTOR O CEILING FIRE ALARM HEAT DETECTOR, FIXED TYPE SAMPLER AS NOTED FIRE ALARM AUDIBLE ALARM, EXPLOSION PROOF WALL MOUNTED AT EXP SCREEN 6'-8" A.F.F. OR 6" BELOW CEILING; WHICHEVER IS LOWER DRIVER AS NOTED FIRE ALARM VISIBLE ALARM, EXPLOSION PROOF, WALL MOUNTED AT EXP DEFINITE PURPOSE CONTACTOR T 6'-8" A.F.F. OR 6" BELOW CEILING; WHICHEVER IS LOWER E 48"AFF FIRE ALARM MANUAL PULL STATION, EXPLOSION PROOF EXP EX EXPELLER O CEILING FIRE ALARM HEAT DETECTOR, FIXED TYPE, EXPLOSION PROOF EXP TAGGING DPDT TS 48"AFF FIRE SUPPRESSION SYSTEM TAMPER SWITCH FS FS 48"AFF FIRE SUPPRESSION SYSTEM FLOW SWITCH PS 48"AFF FIRE SUPPRESSION SYSTEM PRESSURE SWITCH PROCESS EQUIPMENT TAGGING PROCESS SUB AREA DEVICE NUMBER SUB -DEVICE NUMBER PROCESS MAIN AREA EQUIPMENT EQUIPMENT: A AUGER G GRINDER AC AIR COMPRESSOR ICS INDENTED CYLINDER SEPARATOR ASC AIR SCREEN CLEANER MX MIXER B BLOWER P PUMP C CONVEYOR PR PRESS CFD CHEMICAL FEEDER S SAMPLER CP CONTROL PANEL SC SCREEN D DRIVER SV SOLENOID VALVE DPC DEFINITE PURPOSE CONTACTOR T TANK E ELEVATOR V VALVE EX EXPELLER ZS POSITION SWITCH INSTRUMENT & FUNCTION TAGGING LLL = FUNCTIONAL INSTRUMENT IDENTIFICATION LETTERS FROM INSTRUMENT IDENTIFICATION TABLE. LLL NNNa a LETTER SUFFIX TO DISTINGUISH BETWEEN INSTRUMENTS IN LOOP WITH SAME FUNCTIONAL IDENTIFICATION. (USED AS REQ'D.) NNN = LOOP NUMBER DUCTBANK SYMBOL KEY NEW CONDUIT, TYP. O ® 7 O EXISTING CONDUIT, TYP. NOTE: REFER TO DUCTBANK SCHEDULE & PLANS FOR EXACT NUMBER & SIZE OF CONDUITS. A OR AMP AMPERE A.C. ALTERNATING CURRENT AF FRAME AMPERE A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE A.I.C. AMPERE INTERRUPTING CURRENT AS AMMETER SELECTOR SWITCH AT TRIP AMPERE A.T.S. AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AWG AMERICAN WIRE GAUGE B.F.G. BELOW FINISHED GRADE BLDG. BUILDING C COUNTERTOP RECEPTACLE C OR COND. CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CP CONTROL PANEL CPT CONTROL PANEL TRANSFORMER CR CONTROL RELAY DESIG DESIGNATION DIA. DIAMETER DIV. DIVISION DPDT DOUBLE POLE, DOUBLE THROW DS DISCONNECT SWITCH E.C. ELECTRICAL CONTRACTOR EHH ELECTRIC HANDHOLE EMH ELECTRIC MANHOLE EP EXPLOSION PROOF E.T.R. EXISTING TO REMAIN EUH ELECTRIC UNIT HEATER E.W. EACH WAY EX EXAMPLE EXH EXHAUST FAN FU FUSE FRE FIBERGLASS REINFORCED EPDXY G.C. GENERAL CONTRACTOR GEN GENERATOR ABBREVIATIONS GFCI GROUND FAULT CIRCUIT INTERRUPTER NPT GND. OR GRD. GROUND OE H.I.D. HIGH INTENSITY DISCHARGE P HP HORSEPOWER PH OR 0 H.P.S. HIGH PRESSURE PUMP STATION PM HSPS HIGH SERVICE PUMP STATION PMT HVAC HEAT -VENT -AIR CONDITIONING PNL I.G. ISOLATED GROUND PSI I.D. INNER DIAMETER PT IMC INTERMEDIATE METAL CONDUIT PVC IND. INDUSTRIAL QTY. JB JUNCTION BOX RGS J.I.C. JOINT INDUSTRIAL COUNCIL RVSS KA KILOAMPERE SC KCMIL 1000 CIRCULAR MILS SCC KV KILOVOLT SER KVA KILOVOLT AMPERE SM KW KILOWATT SP LA LIGHTNING ARRESTOR SPD LC LIGHTING CONTACTOR S.S. LTG LIGHTING SWBD MAX MAXIMUM TBA MCB MAIN CIRCUIT BREAKER TBR mA MILI-AMP TCC MC MANUFACTURER'S CABLE TDC MCC MOTOR CONTROL CENTER TYP. MFR MANUFACTURER UE MIN. MINIMUM UH M.L.O. MAIN LUG ONLY UL M.O.D. MOTOR OPERATED DAMPER U.O.N. MS MOTOR STARTER UE MTD. MOUNTED UT N/A NOT APPLICABLE UV N.C. NORMALLY CLOSED V NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION VAC NID NETWORK INTERFACE DEVICE (4 POSITION) VS N.O. NORMALLY OPEN W NO. NUMBER WP RADIATION XFMR GENERAL NOTES: NOMINAL PIPE THREADS OVERHEAD ELECTRIC # OF POLES IN CIRCUIT BREAKER PHASE POWER MONITOR PAD MOUNTED TRANSFORMER PANEL POUNDS PER SQUARE INCH POTENTIAL TRANSFORMER POLYVINYL CHLORIDE QUANTITY RIGID GALVANIZED STEEL REDUCED VOLTAGE SOLID STATE SURGE CAPACITOR SYSTEM CONTROL CENTER SERVICE ENTRANCE RATED SUB -METER SPARE SURGE -PROTECTIVE DEVICE STAINLESS STEEL SWITCHBOARD TO BE ABANDONED TO BE REMOVED TELECOMMUNICATIONS CLOSET TELECOMMUNICATIONS DISTRIBUTION CLOSET TYPICAL UNDERGROUND ELECTRIC UNIT HEATER �wc7l a SUCCEEDING LETTERS W UNDERWRITERS LABORATORY Uv 0 READOUT OR PASSIVE FUNCTION \\��\\I\IIIIIIIII/�����i V\\�P •••,,,,,•• ��.�'/4��� UNLESS OTHERWISE NOTED A ANALYSIS (2) J p �: •P� •. y w Q� B BURNER, COMBUSTION w UNDERGROUND TELEPHONE CLOSE, STOP, DECREASE (1) Z U V)� =U:N o Z:J= ULTRAVIOLET co CONTROL CLOSE �. y'"p �� k?' � w !, N �dj•� ... •••O?�� VOLTS ALTERNATING CIRCUIT VOLTAGE o Lo Q� N Uz°° FLOW, FLOW RATE N Q �Q FAIL (1) G (1) p GLASS, GAUGE, VIEWING DEVICE Qaz U O � a o I CURRENT (ELECTRICAL) INDICATE U v1Z� POWER SCAN K TIME, TIME SCHEDULE TIME RATE OF CHANGE CONTROL STATION w LEVEL w F - LOW (CLOSED) M w MOTOR (1) MIDDLE, INTERMEDIATE N Q (1) O ON OR OPERATE (1) 0(1) w UNIT HEATER FIRST LETTERS a SUCCEEDING LETTERS W UNDERWRITERS LABORATORY MEASURED OR INITIATING VARIABLE VARIABLE MODIFIER READOUT OR PASSIVE FUNCTION \\��\\I\IIIIIIIII/�����i V\\�P •••,,,,,•• ��.�'/4��� UNLESS OTHERWISE NOTED A ANALYSIS (2) J p �: •P� •. y UNDERGROUND ELECTRIC Q� B BURNER, COMBUSTION UNDERGROUND TELEPHONE CLOSE, STOP, DECREASE (1) c O V)� =U:N o Z:J= ULTRAVIOLET co CONTROL CLOSE �. y'"p �� k?' VOLT DIFFERENCE, DIFFERENTIAL !, N �dj•� ... •••O?�� VOLTS ALTERNATING CIRCUIT VOLTAGE - Lo Q� VOLTMETER SELECTOR SWITCH F FLOW, FLOW RATE RATIO Q �Q FAIL (1) G (1) p WIRE WEATHERPROOF TRANSFORMER A. DRAWINGS ARE DIAGRAMMATIC IN NATURE, CONTRACTOR SHALL VERIFY DIMENSIONS PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER DIVISION TRADES TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. LOCATE FIXTURES, DEVICES, ETC. IN ORDER TO AVOID INTERFERENCES. B. ALL WORK SHALL BE PERFORMED AS REQUIRED BY APPLICABLE SECTION OF THE NATIONAL ELECTRICAL CODE, LATEST EDITION, AND ALL GOVERNING LOCAL CODES, LAWS, AND/OR REGULATIONS. C. SYSTEM AND EQUIPMENT GROUNDING CONTINUITY SHALL BE ASSURED AS REQUIRED BY APPLICABLE SECTIONS OF THE NATIONAL ELECTRICAL CODE. D. ALL WIRING SHALL BE TYPE "THHN-THWN" U.O.N.; MINIMUM WIRING SHALL BE #12 (POWER WIRE). ALL WIRE SHALL BE COPPER. MINIMUM CONDUIT SIZE FOR METALLIC CONDUIT TO BE 3/4" AND 1" FOR PVC. E. ALL CIRCUIT PROTECTIVE DEVICES SHALL HAVE THE REQUIRED RATING INTERRUPTING CAPACITY EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT AT ITS SUPPLY TERMINAL; MINIMUM INTERRUPTING CAPACITY. SHALL BE 10,000 AMPS, SYMMETRICAL A.I.C. FOR 120/208V SYSTEMS AND 14,000 AMPS, SYMMETRICAL A.I.C. FOR 277/480V SYSTEMS. REFER TO PANEL SCHEDULES FOR A.I.C. RATINGS. F. ALL OUTDOOR EXPOSED CONDUIT TO BE RIGID GALVANIZED STEEL. TRANSITION FROM UNDERGROUND TO EXPOSED SHALL BE RIGID GALVANIZED STEEL. G. ALL UNDERGROUND CONDUITS TO BE SCHEDULE 40 PVC UNLESS OTHERWISE INDICATED. ALL CONDUITS SHALL INCLUDE A NYLON PULL CORD. INSTRUMENT IDENTIFICATION TABLE ANSI/ISA-5.1-2009 (1) USER'S CHOICE (2) WHEN USED, SYMBOL OR SIGNAL LINE IS INDICATED. NOTE: -1NAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTIOl' wtv REVISION DESCRIPTION FIRST LETTERS a SUCCEEDING LETTERS W LETTER MEASURED OR INITIATING VARIABLE VARIABLE MODIFIER READOUT OR PASSIVE FUNCTION OUTPUT/ACTIVE FUNCTION FUNCTION MODIFIER A ANALYSIS (2) J p ALARM z Q� B BURNER, COMBUSTION (1) CLOSE, STOP, DECREASE (1) OFF (1) C (1) �°z co CONTROL CLOSE D(1) o DIFFERENCE, DIFFERENTIAL OPEN, START, INCREASE (1) 0� E VOLTAGE z (D SENSOR, PRIMARY ELEMENT Q� ENABLED (1) F FLOW, FLOW RATE RATIO Q �Q FAIL (1) G (1) p GLASS, GAUGE, VIEWING DEVICE Qaz U H HAND HIGH (OPENED) I CURRENT (ELECTRICAL) INDICATE J POWER SCAN K TIME, TIME SCHEDULE TIME RATE OF CHANGE CONTROL STATION L LEVEL LIGHT LOW (CLOSED) M MOTOR, MOTION (1) MOTOR (1) MIDDLE, INTERMEDIATE N (1) (1) (1) ON OR OPERATE (1) 0(1) ORIFICE, RESTRICTION OPEN P PRESSURE, VACUUM POINT (TEST CONNECTION) PUMP (1) Q QUANTITY (2) INTEGRATE, TOTALIZE INTEGRATE, TOTALIZE R RADIATION RECORD RUN S SPEED, FREQUENCY SAFETY OR SOLENOID SWITCH STOP T TEMPERATURE TRANSMIT U MULTIVARIABLE (2) MULTIFUNCTION (2) MULTIFUNCTION (2) V VIBRATION, MECHANICAL ANALYSIS VALVE, DAMPER, LOUVER W WEIGHT, FORCE WELL, PROBE X UNCLASSIFIED, (2) X-AXIS ACCESSORY DEVICES, UNCLASSIFIED (2) UNCLASSIFIED (2) UNCLASSIFIED (2) Y EVENT, STATE, PRESENCE Y-AXIS AUXILIARY DEVICES Z POSITION, DIMENSION Z-AXIS, SAFETY INSTRUMENTED SYSTEM DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT (1) USER'S CHOICE (2) WHEN USED, SYMBOL OR SIGNAL LINE IS INDICATED. NOTE: -1NAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTIOl' wtv REVISION DESCRIPTION ti a Z W z Zoo w �Q I— W co 00 J p Q z Q� � CD w <w uj UJ I- �°z co w } w o w o o 0� 0� U zz w z (D U. Q� z co p Q w Q �Q Z 0 o p p U Qaz U LL 0 ti V) Z W z 0 N v I— W co 00 J p Q J W � CD w <w w I- m co w } w o w Lu o 0� 0� U zz w z (D m pCD z (D z co p Q w Q 0 w Z 0 ui CD � C6 p p U p U LL C) V) Z W z WHO v I— W Q J W 111 U_ U) o0 Uj m W U I__ p W0Z J W ` SHEET E-001 EXISTING LAB/BLOWER BUILDING (REFER TO SHEET E-202) STANDBY GENERATOR / SERVICE POLE WITH TRANSFORMER BANK \\ A- AuLr \\ X\0 O 10 \ \ \ \ -r TOP \ DIPS 1300N'f\ REFER TO SHEET E-201 12 / P / / LSH f"'CP —ONE ,3NK 123'� 4TODIP / r' AN4EL: 1300.15' / TOP EL� DIGESTER SLUDGE PUMP : 4 \ STATION WETWELL \ \'A/ DIGESTER SLUDGE PUMP CONTROL PANEL 1 2 DSPCP-500 NOTE: FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION DRAWING NOTES: O1 MOUNT CONTROL PANEL PER DISCONNECT MOUNTING DETAIL ON SHEET E-501. O2 EXACT LOCATION OF DSPCP-500 WILL BE DETERMINED DURING CONSTRUCTION. ��.�eMfflv 10 0 1 20 40 GRAPHIC SCALE I INCH = 20 FEET REVISION DESCRIPTION Ductbank Conduit Schedule Conduit Conduit Tag o. From To Conduit/Wiring Legend No. Conduit Size Remarks 1 SERVICE POLE MCB 4-350 KCMIL 3" 2 EG -1 ATS -1 4-350 KCMIL, #4 GND 6(4)#14 3° 3/4" 3 4 L-25 PANEL L L-27 ill 1" 5 6 PANEL L CHEMICAL BUILDINGS L-1,3 1" 7 CHEMICAL BUILDINGS DISCONNECT SWITCH CHLORINATION BUILDING 3#10, #10GND 3/4" 8 DECHLORINATION BUILDING 3#10, #10GND 3/4" 9 PANEL P CCP -301 P-19,21,23 1 10 CSPCP-350 P-25,27,29 1" 11 SPCP-310 P-26,28,30 ill 12 CSPCP-350 LSH CSPCP350-5 3/4" 13 PANEL P DSPCP-500 P-20,22,24 1„ 14 DSPCP-500 DIGESTER SLUDGE PUMP NO 1 DSPCP500-1 1" 15 DIGESTER SLUDGE PUMP NO 2 DSPCP500-2 1" 16 EG -1 REMOTE ANNUNCIATOR PANEL MANUFACTURER CABLE 1" 17 EXISTING SAMPLER DECHLORINATION BUILDING #16 TSP 3/4" 18 DECHLORINATION BUILDING CHLORINATION BUILDING #16 TSP 3/4" 19 O aG \\ A- AuLr \\ X\0 O 10 \ \ \ \ -r TOP \ DIPS 1300N'f\ REFER TO SHEET E-201 12 / P / / LSH f"'CP —ONE ,3NK 123'� 4TODIP / r' AN4EL: 1300.15' / TOP EL� DIGESTER SLUDGE PUMP : 4 \ STATION WETWELL \ \'A/ DIGESTER SLUDGE PUMP CONTROL PANEL 1 2 DSPCP-500 NOTE: FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION DRAWING NOTES: O1 MOUNT CONTROL PANEL PER DISCONNECT MOUNTING DETAIL ON SHEET E-501. O2 EXACT LOCATION OF DSPCP-500 WILL BE DETERMINED DURING CONSTRUCTION. ��.�eMfflv 10 0 1 20 40 GRAPHIC SCALE I INCH = 20 FEET REVISION DESCRIPTION oLo Uv 0 0 N vo > �Z44- q00 Z•J- w = U •� w - o w r rl � U � C) WW W w F-- /nlnlll 0 � � o L N N Oz w z ( m 0 z (D w z p Q w Q w 0 0 Imo) O V U N Ll r� U W w E- W w I—I � V Q AFilw O aG r� w L oLo .E� 0 N vo > q00 Z•J- = U •� w - o = C) WW W :Lm -�5 F-- /nlnlll 0 > � > LL] H Z (J) W [-- 2 2 Z H W W 2i� W W d Q � LU Z H Q (n J Q 0- 27 27 Q 0 Q z FMQ z 0 LL LL O Z O FM Q Z J 0 ry U 0 Z Z 0 CU G Q 2 N� I..L 0 ti 0 N W Cl) 00 J 0 C) WW W F-- m U) > � > LL] w L } Oz w z ( m 0 z (D w z p Q w Q w 0 0 0 0 D U w SHEET E-1 01 DRAWING NOTE: W o Uv 1 REFER TO DISCONNECT MOUNTING DETAIL ON SHEET E-501. W Z w V� 2 CONNECT TO EXISTING FLOW METER SIGNAL LOOP IN EXISTING • Q� w SAMPLER AND ROUTE FLOW SIGNAL TO NEW CHEMICAL FEED Z U SYSTEMS. � w O c� LrL N F+I � V Ll N U w w E- W I—I � `.J Q O aG CHLORINATION BUILDING DECHLORINATION BUILDING (REFER TO E-203) (REFER TO E-203) Orn �: •�P d : i� _ N r O -Q:cn QW 00 Z:c Lo J- LM � q 75— tea: SPCP-310 >, Q �y ••• Lp i i� m crj eNF1 F_-_- � � CLARIFIER SCREEN PUMP EF I � z 2 O I J L �LuZ DISCONNECT e . SWITCH ON RACK o LU F. L H T:e���— —------- — ----- CLARIFIER NO. 1 CLARIFIER NO. 2 I > O I O Z z L�0> O 17 I Lim Z O O O I Q - I �Lim o REFER TO I Lu 1 � 1 z O U SHEET E-101 G CLARIFIER NO. 1 I ^ Z DRIVE MOTOR I I X11 SLUDGE PUMP I O I CSPCP-350 I � I I SLUDGE PUMP I G N o o I w a) cl) m p o W Q WW Na_ p W W W U) W } W Z 00 Z OZ LSI (j p 0 C/) Z _J-1 m�Cf) p Fo z J o CCP - 301 I D U O I I I — i O9 10 I 11 12 � Z Z I Z O J Q z L Q LL /\ LdI Z0�U REFER O SHEET J U E-101 = U L L ENLARGED ELECTRICAL PLAN U L J SCALE: 1/4"=l' -O" L 4' 2' 0 2' 4' 8' 12' GRAPHIC SCALE 1/4" = 1'-0" SHEET NOTE: E=201 FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION NO. DATE BY REVISION DESCRIPTION Cfnw� 0 Uv w w w� • w � � o c� I—I N EXISTING GENERATOR Uzi (TO BE REMOVED) O� Con 70 11, EXISTING ATS Z (TO BE REMOVED) T^ W x REWORK CIRCUITS FROM w LINE AND LOAD SIDE OF 10 ATS INTO JUNCTION BOX w w 10 w EG -1 STANDBY EXISTING WATER HEATER GENERATOR d O EXISTING PANEL LC r� BLOWER NO. 1 w " (TO BE REPLACED) \`\\`\0�\\\ 11111111 ////6/i//',/ GENERATOR REMOTE ��` �P •''" :��y'�i� 8 ANNUNCIATOR PANELLo 00 e 0) —'' N �'' �'�d0 'd....... M 000� ATS -1 13P I ° / Q OOO I PANEL P 16 I EXISTING TRANSFORMER z I a I EXISTING CHEMICAL FEED Q J EXISTING PANEL H CONTROL PANELS d EXISTING BLOWER 2 w I— CONTROLLER Q I � z EXISTING PANEL L U EXISTING BLOWER 1 w Z CONTROLLER \ (TO BE REPLACED) LU �\ w w � 0� � O �oZ z _ l GCB MCB EXISTING PANEL PG 10 L.L (TO BECOME O 1 JUNCTION BOX) 11 13 W P-2,4,6 P-1,3,5 LL z \ O \ LL O y w z O U Z z Q Q c� ELECTRICAL PLAN 00 SCALE: 3/8"=1'-0" T C) N W J M m ❑ � ?j � O O W m (¢ i i N tZ i ❑ W W W W Z m Z OZ LLI U❑ U c j Z co m H cn ❑ cn Z w O p Q W Q W 0 ❑ ❑ U ❑ U u V Zz 0 Q J J D— J I..L w U O~ J U 0o w J 0o w Q J 3' 2' F 6" 0 1' 2' 5' 8' GRAPHIC SALE 3/8" - 1'-0" SHEET NOTE: E=202 FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION NO. DATE BY REVISION DESCRIPTION 520 CEM EXHAUST FAN CHEMICAL FEED PUMPS AND PIPING (SEE SODIUM HYPOCHLORIDE FEED SCHEMATIC) SODIUM HYPOCHLORIDE CONTAINER (TYP. 2) FIBERGLASS BUILDING F_ L_ 0 2" PVC WATER LINE 2" GATE VALVE (TYP.) I I � SLOPE EMERGENCY FLOOR TO 1 1/4" DRAIN 6zDRAIN EYEWASH STATION 1500 W HEATER CHLORINE GAS < > DETECTOR (MOUNT 8" ABOVE FLOOR) REFER TO SHEET E-201 CHLORINATION BUILDING ELECTRICAL PLAN NOT TO SCALE BACKFLOW PREVENTER NaOCI SOLUTION LINE TO EXISTING FEED LINE REFER TO SHEET E-201 f8" REINFORCED CONCRETE SLAB SCREENED INTAKE LOUVER ---- PANELBOARD (BY BUILDING MFR.) ALARM LIGHT AND AUDIBLE WARNING ALARM IN WEATHERPROOF BOX EXTERNAL FAN CONTROL SWITCH `�2C 'I'M EXHAUST FAN REFER TO — SHEET — — E-201 CHEMICAL FEED PUMPS AND PIPING (SEE SODIUM BISULFATE FEED SCHEMATIC) SODIUM BISULFATE - CONTAINER (TYP. 2) FIBERGLASS BUILDING L_ 1500 W HEATER DRAWING NOTES: O1 ROUTE EXISTING FLOW SIGNAL TO CHEMICAL FEED SYSTEM CONTROLLERS. 2" PVC WATER LINE � M 2" GATE VALVE (TYP.) F "O�z 1 BACKFLOW PREVENTER S02 SOLUTION LINE TO EXISTING FEED LINE ILI w REFER TO SHEET E-201 I I � I Uv 0 SLOPE FLOOR TO 1 1/4" EMERGENC T DRAINEYEWASH RAIN STATION w CHLORINE GAS w DETECTOR (MOUNT W 8" ABOVE FLOOR) m U) W F� REFER TO SHEET E-201 DECHLORINATION BUILDING ELECTRICAL PLAN NOT TO SCALE 8" REINFORCED N, X// - CONCRETE SLAB O _�••�P d•�= i ' o ? N Lr) co ( ��/llllllll\� SCREENED INTAKE LOUVER �- PANELBOARD (BY BUILDING MFR.) ALARM LIGHT AND AUDIBLE WARNING ALARM IN WEATHERPROOF BOX EXTERNAL FAN CONTROL SWITCH NOTE: FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION ��.�eMfflv REVISION DESCRIPTION H Z � W � � Z H W W � � W W d Q � Lu Z H Q (n J Q 0- z z FmQ z 0 LL LL O Z O Fm ti Uv 0 W c') m J p w O O W w Lu W �� d m U) W W N W � w } � 0' OZ O 00 p I—I c� C-1 Z co p Q N Q LU 0 p in U in U O �ll a V N Ll r� V U Z W F--� w w F- W w VD AFilQ wL r � 8" REINFORCED N, X// - CONCRETE SLAB O _�••�P d•�= i ' o ? N Lr) co ( ��/llllllll\� SCREENED INTAKE LOUVER �- PANELBOARD (BY BUILDING MFR.) ALARM LIGHT AND AUDIBLE WARNING ALARM IN WEATHERPROOF BOX EXTERNAL FAN CONTROL SWITCH NOTE: FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION ��.�eMfflv REVISION DESCRIPTION H Z � W � � Z H W W � � W W d Q � Lu Z H Q (n J Q 0- z z FmQ z 0 LL LL O Z O Fm ti 0 N W c') m J p O O W Lu W �� d m U) W W N W � } � 0' OZ Z (D 00 p Z (D w Z co p Q LU Q LU 0 p in U in U LL V z J z n W Q Lu U Q U U w � J w w U SHEET E-203 3 C) 0 w m M 0 0 3 m L w 0 co 0 0 0 N (n C 3 RACEWAY GROUND FINISHED GRADE v 1 W U U INSULATED BUSHING I—I—I I—III—III w WITH GROUND LUG III—III—III-N III—III— � w FINISHED SLAB COORDINATE STUB UP HEIGHT WITH CONCRETE III—III—III III=III—III—SUITABLE BACKFILL III— — = = — BATTERY CHARGER U Z PAD AND EQUIPMENT? REQUIREMENTS I— I = _ = I I= III—III—III—III—III— = I I ELECTRICAL ENCLOSURE CONTROL PANEL i --i 1 I= I= I_111=111=111=1p—ELECTRICAL WARNING TAPE I I w ' ° ° ° ° < ° ° a° ° a ° ° ° a ° N 11=111=111=111=1 I 1=1 I 1=1 I I I I ENCLOSURE ° ° ° ° a° `° °°° ° °`° ° ° ° d COMPACTED WASHED STONE 1 I #4 ® 8" E.W. PLACE I AT MID DEPTH �� I UNIT CIRCUIT o ° a ;o SCREENINGS 4 MIN. ALL SIDES BREAKERS 8" THICK CONCRETE O O SCHEDULE 40 PVC SLAB (3,000 PSI) I I U CONDUITS. NUMBER OF Z C SCHEDULE 40 PVLt CONDUITS AS INDICATED ON DRAWING ° ° ° °° ° w W4 ° d ° d a /.� ��% MIN. 36" CLEARANCE ROCK OR S OIL 3" 3��°BALL SIDES F-1° . MIN. MIN./�� ^^ ^^ ^^ ^^ ^^ ^^ ^^ ^^ ^^ ^^ ^^ ^^ RIGID GALVANIZED NOTES: 12" TYP.^ SUB BASE FUEL TANK RIGID TO PVC ADAPTOR STEEL CONDUIT 1. CONTRACTOR TO RESTORE SITE TO EXISTING CONDITION. 1'-0" THICK LAYER COARSE AGGREGATE ° ~ w (AASHTO NO. 8 OR NO. 57) NOTES CONCRETE W 1. THIS DETAIL APPLIES TO ALL UNDERGROUND CONDUITS WHERE PVC IS UTILIZED. PVC SHALL NOT BE EXTENDED ABOVE GRADE UNLESS SPECIFICALLY APPROVED. BASE JJ I W w ('E'TYPICAL CONDUIT STUB UP E TYPICAL SITE ELECTRICAL TRENCH DETAIL E EXTERIOR ELECTRICAL EQUIPMENT PADTO Q 1 NOT TO SCALE ATS 2 NOT TO SCALE 3 NOT TO SCALE TO PANELBOARD TO SCADA (FUTURE) STRUT 1/2" STAINLESS o O ` \ �. .• y O :•�'P d BOLT NOTE: E GENERATOR DETAIL = o c w - Lo =�; J� �:� _ FINAL DRAWING — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR CONSTRUCTION 4 NOT TO SCALE O 0 o c, = W (nom ca•J= �y C) >. NN .,�y�.d •��. m //11111111111 CHANNEL NUT DISCONNECT SWITCH i i ALTERNATE SUPPLY IS i� UTILITY SUPPLY NOT A SEPARATELY AS NEEDED STAINLESS STEEL SAWCUT AND SEAL BOTTOM OF SUBGRADE TRANSFORMER SOLIDLY DERIVED SYSTEM IF THE AS REQ'D. z STRUT i GROUNDED SYSTEM i NEUTRAL IS SOLIDLY 6" MIN. 3' #4 BARS 1'-0' O.C. 6" IN. 3' 6" MIN. IL i INTERCONNECTED 12" MAX. 12" MAX. 7 Q J 0 --- U) O 0 o PAVEMENT ON-SITE GENERATOR '� W �/,\�/.\� \�/.\ I I—I � I—I � I—I � I—I 11—I � I—I � I—III—I I/\�/.\�/•\�/`\�/. i -- - - - - - -- i — FF=TF=TF=TF=TF=TF=TF=TF=�I I I 11 I I 11 I I 11 I I 11 I I z 111=111=111=1N 111=111=111=111 i i w U STAINLESS STEEL 11=III=III=III-II=III=III =—_ —COMPACTED BACKFILL — — —III 111= = = r______ _ _______________ i 3-PHASE, 4 -WIRE i kk = # _ I 1 # _ # _ # _ # _ II 1 II 1 # II _ # _ 1 II 1/2" STAINLESS STEEL STRUT — — — METALLIC IDENTIFICATION _ _ _ _ —_ 111=111=111=111 111=111=111=111 TAPE i i % SERVICE i _ _ _ i FRAME __-i GROUND o o X z Q W a w BOLT AND NUT 0 ° M _ _ _ _ _ _ _ _ —I—I—I I—III--I—I—I _ w I I 11 I I 11 I I 11 I I I I I III—III—III—III III—III—I 1=1 I I EQUIPMENT ¢ : 0N �SERVICE ° III—III--I—I—I—III EGC I I 11 I I 11 I I 11 I I 11 I I Q Z Z o o #3 TYPICAL ® 12" TOP=1 1-1 1-1 1-111-1 1-1 1-111-11 AND BOTTOM. ISI—ISI—ISI—ISI � � OVERCURRENT _--III—III N ., OFF —III 111—I 1=111-1 1-1 1-111-11 III=11 III—III III—III—III=III 1" MIN. 1=1 � 1=1 � 1= AND GND ) DISCONNECTING _#_#_#_#_#_#_#_ w ° a 3000 PSI CONCRETE � i MEANS �� N � II II II II II II II II II Lim z _ D 0 0 ° a° TOPCORER CENTERTIEACOH SIDEEACH &NBOTTOM. I I 1 I I 1 I I 1 I I I I I LL O 0 o REFER TO EXTERIOR ELECTRICAL ° TIE ALL R -BARS TOGETHER EACH a° °° JOINT &STIRUPS. EACH CORNER AND ALL EGC w7% I I Z I I I I I I I I I I I W` O U EQUIPMENT PAD 0 i� °° a° z ° _ U)I , "' ° ° m I I I I I I I I I I I I I I_j STAINLESS STEEL POST BASE a° ° ° 4" PVC CONDUIT (TYP.) r--- --� N I _ # _ II II # _ # _ # _ # _ II II II II # II _ # _ II II Z Q °o ° °° ° i i I$=�$=#_�$_#_�$_#=�$=1 Q M ° ° a • II II II II II II II II II °4 4a II II II II II II II II II REFER TO POST BASE FOUNDATION DETAIL �� �� �� - EGC 3 POLE TRANSFER H EQUIPMENT SWITCH I I I I I I I I I I I I I I 3" 3 1/2" GROUNDING Q Q_#_#_#_#_#_#_#_ MIN. MIN. CONDUCTOR (GREEN) Of I I I '04 I I I I I I I I I I I 000 i L N i (n I$=$k=$k=$k=$k=$k=$k=$k=$� N L LOAD J II II II II II II II II II w J �, M m p II II II II II II II II II ow Qww 0o � �w Oz w(D o 0 cn z co p Q w Q w 0 TYPICAL CONCRETE ENCASED ('E'NDISCONNECT MOUNTING DETAIL E DUCTBANK UNDER PAVEMENT DETAIL E SERVICE & GENERATOR GROUNDING DETAIL FINISHED GRADE 5 NOT TO SCALE 6 NOT TO SCALE 7 NOT TO SCALE 4" ��^^ vJ _° ° ° G a ° G ° III—ISI—II—ISI �—_�._�—�_—_°�_ -111-111-111—I I � �_.-_�—a � Q POST BASE 4/0 BARE GRD BETWEEN RODS CONDUCTOR (TYP) EXOTHERMIC WELD FINISHED GRADE— =1=1 1=1 I—III—III—I—I—I I= II III—III—III—III—III—III—III—III—III I—III—III—III—III-11 I 3" 3/8" S.S. NUT AND CONNECTION (TYP) lllllllllllllll�lii�iii�iii�� w WASHER (TYP.) INSULATED GROUND M J 6"x6"- W2.9xW2.9 WWF WIRE TO PANELBOARD Z NOTES: FINISHED FLOOR IN RGS CONDUIT PADS SHALL BE FIELD POURED. II II1. 2. CONCRETE SHALL HAVE A MINIMUM ULTIMATE 28 DAY COMPRESSIVE STRENGTH OF NOT LESS THAN 3000 PSI. 4000 PSI CONCRETE I I I 3. 4. PAD SHALL BE POURED TO 4" ABOVE GRADE, ALL EDGES OF CONCRETE EXPOSED ABOVE GROUND GROUT SHALL NOT BE SHALL HAVE A 1" SUBSTITUTED FOR CONCRETE CHAMFER. MIX. TOP OF STEEL FOUNDATION BOLTS; MIN. SIZE GROUNDING 5. ANY DISTURBED EARTH OR FILL SHALL BE COMPACTED PRIOR TO INSTALLING PAD. FT�x x x x x x x x FINISHED SLAB 3/8" DIA. BY 12" LONG TYP. OF 4 / ( ) BUSHING 6. 7. PROVIDE ANCHOR BOLTS PER MANUFACTURERS RECOMMENDATIONS. ADJUST FOUNDATION SIZE TO MATCH ACTUAL REQUIREMENTS OR SPECIFIC GENERATOR INSTALLED. #4 AWG GROUND WIRE 8. CONCRETE SHALL EXTEND 12" BEYOND GENERATOR ENCLOSURE. w #4 DOWELS ® 12" C/C ALL SIDES 6 5/8" J NOTES: 0 0 3/4" x 1 COPPERCLAD AD W STEEL GRD ROD 1. PROVIDE HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD TO BE 2" (TYP) LARGER TEN THE FOOTPRINT OF THE EQUIPMENT ON THE SIDES AND 1" LARGER IN THEFRONT � E GENERATOR PAD DETAIL 30' MIN (TYP) 0 0 11 NOT TO SCALE SHEET POST BASE E INDOOR EQUIPMENT PAD DETAIL E POST BASE FOUNDATION DETAIL E GROUNDING COUNTERPOISE DETAIL E501 8 NOT TO SCALE 1 o NOT TO SCALE = 9 NOT TO SCALE NO. DATE BY REVISION DESCRIPTION W NOTES: [� U 1) ALL CONCRETE TO BE 3000 PSI. ^ Z � w w 2) PROVIDE "H" AND "L" DIMENSIONS AS REQUIRED. FOR SPECIFIC Z U EQUIPMENT LAYOUT. 3) EVENLY SPACE ALL REQUIRED INTERMEDIATE SUPPORTS. w AS REQUIREDCp c� UziPROVIDE INTERMEDIATE 4"0 GALVANIZED SCHEDULE SUPPORTS PER TABLE 40 PIPE WITH GALVANIZED REQUIREMENTS STEEL PIPE CAP O � a o r� U W¢ SST UNISTRUT (LOCATE AS W REQUIRED FOR EQUIPMENT w o ro MOUNTING AND RACEWAY Z 0 SYSTEM SUPPORT) w w Or 0X aG N O G� o z xo\1111/ CONCRETE FOUNDATIONL _ v .N o Z: 1 W cr) � 2" 12" c� i O .0 FINISHED GRADE }' — a? if 04 cz N iii/ �/ '•'•...•••' Q\�,� co o o o ////►IInn1\\\ M � Z z QJ w U) 0 � �aQ Z U 12"0 12"0 W Z <2i ww >FO ('E"EQUIPMENT SUPPORT DETAIL ~ 0�/ Z Z 1 NOT TO SCALE L.L0 LL z Q- D CONSTRUCT PANEL MOUNTS 3: [-- Lim O SPCP-310 ROUND OFF EXPOSED AND UNISTRUT IN A WAY THAT LJ NEMA 4X ENCLOSURE CORNERS OF UNISTRUT, TYP. OFFSETS PANEL AS FAR OUT 1 � J 1 z O U SECURE CONTROL OF WALKWAY AS POSSIBLE CC 7n. - PANEL TO UNISTRUT Q G W/1/4" SST UNISTRUT 1 BOLTS AND NUTS �+ II II O I !110 1 11 101! !1 0 II II D V II II � Z O � I I I I II II N 0 SST UNISTRUT (LOCATE ON a z p 1 1 p p 1 1 REAR OF POSTS, SPACE AS Cw-� O REQUIRED FOR EQUIPMENT a MOUNTING AND RACEWAY vii � w 11 SYSTEM SUPPORT)CD - ti I I I I I I I I I I I I N I I I I II II I I I I w q m o - r - - - - - M F�F CD - H m < > W W O 0- W W ' W 11 1 1 TOP HANDRAIL 1 p Z m Z[--: Q� 1 i i i i Z W (D p(D Cn Z o I 1 HANDRAIL POST co I I I 10 U 0 O LLL I I I I I I SEAL FITTING (TYPICAL) BOTTOM HANDRAIL - i O O - U) I i I I I I 1 NOTE: w 2" RGS 0 I I I CONDUIT SUPPORT POSTS FINAL DRAWING — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR CONSTRUCTION TOP OF TANK WALL I II (TYPICAL OF 2) J II II Q 4��� = o =01 I I I o 0 II II 2" TWO HOLE STRAPS, TYP. SEE NOTE B. fl U LU LU CONDUITS FROM ELECTRICAL EQUIPMENT ENCLOSURE CABLES PUMPS AND LEVEL DEVICES SHEET TYPICAL TANK MOUNTING FOR E CLARIFIER SCUM CONTROL PANEL (SPCP-310) 2 NOT TO SCALE NO. DATE BY REVISION DESCRIPTION E=502 0 Uv w w � w DIGESTER SLUDGE PUMP CLARIFIER NO. 1 CONTROL PANEL CLARIFIER SCUM PUMP CONTROL PANEL CONTROL PANEL 'DSPCP-500' 'CCP -301' 'SPCP-310' o _ _ _ _ I� Z N H �ATL� 'ATL N A 13.8 KV O Q� UL 3-50KVA POLE MOUNTED U �480Y/277V ppM TRANSFORMER BANK U U \ N U U NEW SERVICE CONNECTION M r^ W ON EXISTING SERVICE POLE L J Z w STANDBY a a m Z j U U N Q w 4-350 KCMIL, 3" C GENERATOR U a/ EG -1 N La - #2 #2 CU MCB GCB '�`� �I I 's� `S w w GROUNDING NEMA 3R NEMA 3R ci o o ci i ci o ELECTRODE 14 KAIC ` 14 KAIC > a a > o > M r --i CONDUCTOR 300A SERVICE ENTRANCE 1300A SERVICE ENTRANCE o 0 0 o a o ca) (� Q N RATED RATED � o o 00 0 00 w Z O G 3-350 KCMIL, 4 GND, 3" C a ��III111111//// 4-350 KCMIL, #4 GND, 3" C # D m \������ �'/,i w w ,.� �,. , ... .•� %. ATS -1 p �o N ZO n0 It N— Nto ff Wdv>: 00 z•J= cn N wZ wZ N w0 00 w0 c T 0O 00w -.4- V)� �•J� N H H N N LLI I c�O c�O I J I .//�j 0ij��.�d�/ /IIIIIIII\���C�vQ�\`P•\ \� ` NWN i(Y � � ceQ CL Da Da a UD CL UO EXISTING SERVICE EL -34 L� DROP, TO BE REMOVED 0 0 DIGESTER SLUDGE PUMP CLARIFIER NO. 1 CLARIFIER SCUM PUMP CONTROL PANEL ONE -LINE CONTROL PANEL ONE -LINE CONTROL PANEL ONE -LINE Q 3#3, #8 GND, 1 1/4" C NOT TO SCALE NOT TO SCALE NOT TO SCALE z 3-350 KCMIL, #4 GND, 3" C Q Z J PANEL PANEL O P H 3#6, #10 GND, U 1" C I— W Z _ Q2 Q3#8, #10 GND, W W 1" C 3#4, #8 GND, 1 1/4" C 3#3, #8 GND, 1 1/4" C> O CLARIFIER SLUDGE PUMP O Z Z CONTROL PANEL 'DSPCP-350'_ 0 480V ATL ATL ATL ATL EG -1 BLOWER CONTROLLER m NO. 1C Lim z I I U c I 30 KVA EXISTING L J 208V 120 LimO PANEL P � / � (TO BECOME JUNCTION - W z O U BOX) N EXISTING Li i o (/) —j Z Lo 0 (, U U U a BLOWER BLOWER - _ _ a NEMA 4X SS Q TO PLANT NO. 2 NO. 1 L L L L 0 JUNCTION BOX w LL EQUIPMENT J J J J Z SLUDGE PUMP - EXISTING # # U U U U J 3 6, 8 GND, 1" C a a a a RAKES -PUMP o \ U O PANEL Of LL- LL- LL- L �L 240/60/2/NF/3R _ 2 \ r6 N Kj It LJ a \ w M z M U I I I I m O m O U Q Q 3#10, #10 GND, 3/4" C > a a a a > C'4 "' 4#10, #10 GND, 3/4" C m N N N N w w I I - w m z":t NEW NEMA 12 t U U U U � a J J o M N JUNCTION BOX DECHLORINATION i CHLORINATION M m p BUILDING I I I I BUILDING w w o J PANELBOARD i PANELBOARD 2 2 2 2 40 o w m<>> 2 L ---J L ---J W �} lY Lu Lu W N N W .-. Of Oc'o Z m Z Q ch O O O O W N H = z LLI (] (j Z CD EXISTING �z �z Nz Nz Jd a ~ w0 m F U) 0 U) z w o ATS TO BE oa oa oa oa _ m:m O 0 U o O LU L REMOVED EXISTING a) z m z m z m z _ 0 a a Q < o = N REWORK EXISTING CIRCUIT Z 04 GENERATOR � w a w a w a w a a 0 1— -i Q -i Q a I o � z m TO BE REMOVED N �� �� �� �� �� �w ww �w�w zw ,`)� w oton o �o �o �o Ld a3 ZLd z ZzQ az aZ 3 =w= �/^J I J J J J J J J J U' O a_ Q 0 Q (w') m O Q O a I O �' � N vI a U V) c.) V) C) V) c.) U) o LL .. a `. a .. c) .. a a m i a W Z CLARIFIER SLUDGE PUMP STANDBY GENERATOR BLOWER CONTROLLER NO. 1 J CONTROL PANEL ONE -LINE ONE -LINE ONE -LINE W EXIST. 3#10, #10 GND, 3/4" C NOT TO SCALE NOT TO SCALE NOT TO SCALE z DISCONNECT O EXISTING CIRCUIT J r� EXISTING EXISTING v PANEL PANEL A ' B LC I— U Lu J W POWER ONE -LINE NOT TO SCALE SHEET NOTE: E=601 FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION NO. DATE BY REVISION DESCRIPTION 0 UU w � w a azo N �I N EXISTING PANEL L BUS AMP 100A MIN. A.I.C. 10,000 MAIN BREAKER 100A MOUNTING SURFACE PHASE 3 WIRE 4 VOLTAGE 120/208 v LOCATION LAB ROOM NEMA TYPE 12 NOTE GE TYPE NLAB PANELBOARD ax USE GE THQB BREAKERS O �ll BREAKER LOAD (KW) WIRE GND. COND COND GND. WIRE LOAD (KW) BREAKER CKT DESCRIPTION DESCRIPTION CKT AMP POLES A B C NO SIZE SIZE SIZE SIZE SIZE SIZE NO A B C POLES AMP QI N 50 2 2.5 3 6 10 3/4 - 1 20 LAB LIGHTS 2 Ur Z CHLOR./ DECHLOR. BUILDINGS 3 2.5 - 1 20 OUTSIDE/BLOWER ROOM LIGHTS 4 �/1 Z 5 BLOWER RM RECEPT. 20 1 - - 1 20 LAB RECEIPT. 6 J 7 BILLBOARD LIGHT ON RD 20 1 - - 1 20 RECEPTACLES 8 QUI' w Q 9 CONTROL CKT/OUTSIDE LIGHTS 20 1 - - 1 20 LAB RECEIPT. 10 w w w 11 SPARE 20 1 - - 1 20 SAMPLER 12 Z' 13 30 2 - - 1 20 LAB RECEIPT. 14 WATER HEATER O 15 - - 1 20 RECEPTACLES 16 Z, 17 BATHROOM 20 1 - - 1 20 CONTROL CABINET HEATER 18 w 19 30 3 - - 1 20 CONTROL CABINET HEATER 20 \\\\\�//i 21 PANEL LC/ PANEL B - - 1 20 CONTROL CABINET HEATER 22 ��� Q� ••• •. �� 4, >' `� \?'per•. , .\y�� m m CDJ� Z: - 23 - - - 1 20 CONTROL CABINET HEATER 24 O n^o dv�: �k 25 GENERATOR HEATER 25 1 2 2 10 10 3/4 1 20 UNKNOWN 26 � O =v ,� V)� �k 27 GEN. BATT. CHARGER 20 1 0.6 2 12 12 3/4 - 1 20 UNKNOWN 28 (� p CN �:��d 29 STOVE 20 1 - SPACE -PFFB 30 cz _� N %dam •.d Q\�� ci3 ��/11111111100 O\\\\ SUB -TOTAL LOAD KW 4.5 3.1 0 SUB -TOTAL LOAD KW 0 0 0 TOTAL LOAD KW 4.5 3.1 0 �k ADD NEW CIRCUITS FOR GENERATOR INTO EXISTING SPACE. �k �k ADD NEW CIRCUIT FOR THE CHLORINATION AND DECHLORINATION BUILDINGS INTO EXISTING SPACE. z THE EXISTING TRANSFER SWITCH IS BEING REMOVED. REWORK THE CIRCUIT TO POWER EXISTING LOADS THAT WERE ON THE TRANSFER SWITCH. Z Q Z O w�a� �z a � Lu Z < 2i ww >FO �0Zz 0 - PANEL P BUS AMP 400 MIN. A.I.C. 10,000 MAIN BREAKER 300A Lim z MOUNTING SURFACE PHASE 3 WIRE 3 VOLTAGE 480V z LOCATION BLOWER ROOM NEMA TYPE 12 NOTE PROVIDE INTEGRAL 240kA SURGE PROTECTIVE DEVICE � � U O BREAKER LOAD (KW) WIRE GND. COND COND GND. WIRE LOAD (KW) BREAKER W Z O CKT DESCRIPTION DESCRIPTION CKT AMP POLES A B C NO SIZE SIZE SIZE SIZE SIZE SIZE NO A B C POLES AMP //�� 1 100 3 11.1 3 3 8 1 1/4 1 1/4 8 3 3 11.1 3 80 2 V J _J Z _ 3 BLOWER NO. 1 CONTROLLER 11.1 11.1 BLOWER NO. 2 CONTROLLER 4 Q 5 11.1 11.1 6 7 100 3 19.4 3 3 8 11/4 11/4 8 4 3 8.31 3 70 8 V 9 PANEL H 19.4 8.31 30 KVA TRANSFORMER 10 O 11 19.4 8.31 12 13 40 3 5.54 3 8 10 1 1 10 6 3 5.54 3 50 14 ti 15 PLANT EQUIPMENT 5.54 5.54 SLUDGE PUMP - RAKE PUMP 16 0 N 17 5.54 5.54 18 w 19 20 3 2.77 3 10 10 3/4 3/4 10 10 3 1.88 3 15 20 o w Q w w o CLARIFIER NO. 1 CONTROL PANEL DIGESTER SLUDGE PUMP 21 2.77 1.88 CONTROL PANEL 22 a p Lu w w w (CCP -301) Lu (DSPCP-500) Lu Lu m Z � 23 2.77 1.88 24 ¢ Oz uj U p (� z c 25 30 3 3.77 3 8 8 1 3/4 10 10 3 0.94 3 15 26 000 Q w Q w 0 m CLARIFIER SLUDGE PUMP CD z Lu CLARIFIER SCUM PUMP CONTROL D U D U IL 27 CONTROL PANEL 3.77 0.94 PANEL 28 29 (CSPCP-350) 3.77 0.94 30 ' ^ 31 SPACE - PFFB SPACE - PFFB 32 CJI IJ 33 SPACE - PFFB SPACE - PFFB 34 J 35 SPACE - PFFB SPACE - PFFB 36 37 SPACE - PFFB SPACE - PFFB 38 39 SPACE - PFFB SPACE - PFFB 40 W 41 SPACE - PFFB SPACE - PFFB 42 2 (Un SUB -TOTAL LOAD KW 42.6 42.6 42.6 SUB -TOTAL LOAD KW 27.8 27.8 27.8 _ r TOTAL LOAD KW 70.3 70.3 70.3 J U_ U w w SHEET NOTE: E=602 FINAL DRAWING - FOR REVIEW PURPOSES ONLY - NOT RELEASED FOR CONSTRUCTION NO. DATE BY REVISION DESCRIPTION ENGINE -GENERATOR SET SCHEDULE STANDBY STARTING OUTPUT MARK RATING RATED VOLTAGE KVA AT 15% CB TRIP (KW) PF VOLTAGE DIP RATING AUTOMATIC TRANSFER SWITCH SCHEDULE SWITCH CLOSING AND ENCLOSURE MARK RATING SWITCHED VOLTAGE WITHSTAND RATING TYPE (A) POLES (RMS SYM. A) ATS -1 400 3 277/480V, 30, 4W, 60 HZ 22,000 12 EG -1 150 0.8 277/480V, 3�6, 4W, 60 HZ 420 300 AUTOMATIC TRANSFER SWITCH SCHEDULE SWITCH CLOSING AND ENCLOSURE MARK RATING SWITCHED VOLTAGE WITHSTAND RATING TYPE (A) POLES (RMS SYM. A) (NEMA RATING) ATS -1 400 3 277/480V, 30, 4W, 60 HZ 22,000 12