May 8, 2018
Mr. Edward Goscicki, PE
Union County Department of Public Works
500 North Main Street, Suite 400
Monroe, NC 28112
SUBJECT: Compliance Evaluation Inspection
Crooked Creek WWTP
NPDES Permit #NC0069841
Union County, NC
Dear Mr. Goscicki:
ROY C OOPE1R
Gayff var
A ICHALEL S_ REGAN
Secrelan.
LLVDA CLTLPEPPER
MRF1M D&gCADr
On April 4, 2018, Roberto Scheller of this Office conducted an inspection at the subject facility.
This inspection was conducted as a Compliance Evaluation Inspection (CEI) to insure compliance with permit
requirements and conditions. At the time of inspection subject facility appeared to be well maintained and
operated. We wish to thank you and the operating staff for assistance regarding this inspection.
The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to
contact Roberto Scheller, of the Mooresville Regional Office, at 704-663-1699 or roberto.scheller@ncdenr.gov.
Enclosure: Inspection Report
cc: ORC - dannysmith@unionconc.gov
Sincerely,
DocuSigned by:
A14'gW. Coreyasinger, Regional Supervisor
Water Quality Regional Operations Section
Mooresville Regional Office
State of North Carolina I Environmental Quality I Water Resources
610 East Center Avenue, Suite 301, Mooresville, NC 28115
704-663-1699
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 15 I 3 I NCO069841 111 12 I 18/04/04 I17 18 I S i 19 LG] i 201 I
211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166
Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ----------------------Reserved-------------------
67 70I�_71 I 72 Lr] 73I i74 751 1 1 1 1 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
09:40AM 18/04/04
09/10/01
Crooked Creek WWTP #2
4015 Sardis Church Rd
Exit Time/Date
Permit Expiration Date
Monroe NC 28110
12:12PM 18/04/04
14/01/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Danny L Smith/ORC//
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Edward Goscicki,500 N Main St -Ste 500 Monroe NC 281124730/Public Works
Director/704-296-4212/7042964232 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
DocuSigned by:
Roberto Scheller C� MRO WQ//252-946-6481/ 5/8/2018
E91C2A007838943E.-
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger MRO WQ//704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
5/9/2018
Page#
EA14CC681AF27425... /
NPDES yr/mo/day Inspection Type
NCO069841 111 121 18/04/04 1 17 18 JCJ
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit: NCO069841 Owner - Facility: Crooked Creek WWTP #2
Inspection Date: 04/04/2018 Inspection Type: Compliance Evaluation
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
0
❑
❑
❑
application?
0
❑
❑
❑
Is the facility as described in the permit?
❑
0
❑
❑
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: Permit is under renewal. Facilitv has chanced with construction of EQ basin and influent
pumps.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
❑
❑
❑
Is a copy of the current NPDES permit available on site?
❑
❑
❑
Page#
3
Permit: NCO069841
Inspection Date: 04/04/2018
Record Keeping
Facility has copy of previous year's Annual Report on file for review?
Comment: Records are well maintained and in good order.
Owner - Facility: Crooked Creek WWTP #2
Inspection Type: Compliance Evaluation
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
■ ❑ ❑ ❑
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
■
Comment: Field analyses is performed under field certification #5658. Laboratory analyses are
performed by Charlotte Water Laboratory Services (Certification # 192). Toxicity is
performed by ETT Laboratory in Greer, South Carolina.
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment: New influent pump station newly constructed and not in use at time of inspection
Eaualization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
1[TM►rem ►/_M►1=M
❑ ❑ ■ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
Page# 4
Permit: NCO069841 Owner - Facility: Crooked Creek WWTP #2
Inspection Date: 04/04/2018 Inspection Type: Compliance Evaluation
Equalization Basins Yes No NA NE
Comment: At time of inspection EQ basin was being tested and was full of water.
Bar Screens
Yes No NA NE
Type of bar screen
0
❑
❑
❑
a.Manual
❑
❑
❑
❑
b.Mechanical
0
❑
❑
❑
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Debris from barscreen is placed in dumpster and disposed of at county landfill.
Chemical Feed
Yes No NA NE
Is containment adequate?
0
❑
❑
❑
Is storage adequate?
0
❑
❑
❑
Are backup pumps available?
0
❑
❑
❑
Is the site free of excessive leaking?
0
❑
❑
❑
Comment: Liquid lime is being feed for suppplemental alkalinity.
Oxidation Ditches
Yes No NA NE
Are the aerators operational?
0
❑
❑
❑
Are the aerators free of excessive solids build up?
0
❑
❑
❑
# Is the foam the proper color for the treatment process?
0
❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
0
❑
❑
❑
Is the DO level acceptable?
❑
❑
❑
0
Are settleometer results acceptable (> 30 minutes)?
❑
❑
❑
0
Is the DO level acceptable?(1.0 to 3.0 mg/1)
❑
❑
❑
0
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes)
❑
❑
❑
0
Comment:
Pumps -RAS -WAS Yes No NA NE
Are pumps in place? 0 ❑ ❑ ❑
Are pumps operational? 0 ❑ ❑ ❑
Page# 5
Permit: NC0069841
Inspection Date: 04/04/2018
Pumps -RAS -WAS
Are there adequate spare parts and supplies on site?
Comment: WAS is pumped to one of five aerobic digesters.
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Owner - Facility: Crooked Creek WWTP #2
Inspection Type: Compliance Evaluation
Yes No NA NE
❑ ❑ ❑ ■
Yes No NA NE
•
❑
❑
❑
•
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
Comment: Facility has 5 aerobic sludge digesters. Facility also has drying beds that are not in use.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
■
Comment: At time of inspection effluent from secondary clarifiers was clear with few suspended solids.
Filtration (High Rate Tertiary)
Type of operation:
Is the filter media present?
Is the filter surface free of clogging?
Is the filter free of growth?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids and filter media?
Yes No NA NE
Down flow
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
Page# 6
Permit: NCO069841 Owner - Facility: Crooked Creek WWTP #2
Inspection Date: 04/04/2018 Inspection Type: Compliance Evaluation
Filtration (High Rate Tertiary) Yes No NA NE
Comment: Sand filters are down for maintenance.
Disinfection - UV
Yes No NA NE
Are extra UV bulbs available on site?
0
❑
❑
❑
Are UV bulbs clean?
0
❑
❑
❑
Is UV intensity adequate?
❑
❑
❑
0
Is transmittance at or above designed level?
❑
❑
❑
0
Is there a backup system on site?
0
❑
❑
❑
Is effluent clear and free of solids?
0
❑
❑
❑
Comment:
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected below all treatment units?
0
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
❑
❑
❑
0
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment: At time of inspection effluent sampler was recorded at <1 degrees Celsius.
Pump Station - Effluent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
❑
❑
❑
Are all pumps present?
❑
❑
❑
Are all pumps operable?
0
❑
❑
❑
Are float controls operable?
0
❑
❑
❑
Is SCADA telemetry available and operational?
❑
❑
❑
0
Is audible and visual alarm available and operational?
❑
❑
❑
0
Comment: One of three effluent pumps removed for maintenance. At the point of discharge into North
Fork Crooked Creek effluent was clear with no visible susDended solids or foam.
Page# 7