Loading...
HomeMy WebLinkAboutNC0023884_Monitoring Information_20180501 $aIisburj'Rwan� May 1, 2018 RECEEVED/DENR/DWR Mr. Monti Hassan MAY 0 7 2018 NCDENR/DWQ/PERCS Unit Water Resources 1617 Mail Service Center Panting Section Raleigh,N.C. 27699-1617 Subject: City of Salisbury Revised Long Term Monitoring Plan Dear Mr. Hassan: The City of Salisbury is submitting a revised Long Term Monitoring Plan(LTMP)with the following revision: • The Nitrite-Nitrate detection limit was changed from 0.05 mg/L to 0.3 mg/L Please contact me at(704) 216-7539 if you have any questions regarding Salisbury's LTMP. Sincerely, Sonja Basinger Environmental Services Manager Enclosure: Revised Salisbury LTMP cc: Wes Bell, DEQ/DWR/MRO PT Files 1915 Grubb Ferry Road Salisbury-Rowan Utilities Telephone(704)638-5375 Salisbury,NC 28144-1248 Environmental Services Division Fax (704)638-8476 City of Salisbury City of Salisbury WWTP NPDES NC0023884 Long Term Monitoring Plan Revised May 1, 2018 Sampling Points and Frequencies: Salisbury has a unique situation in that we have two Treatment Trains at two separate physical locations that the SIU's discharge into. The chlorinated effluent from the Town Creek Treatment Train(TE)is combined with the Grant Creek Treatment Train chlorinated effluent(GE). The combined chlorinated effluents(YE)join together on the Grant Creek property are dechlorinated,then flow through cascade aeration,and then discharge into the Yadkin River.Although not permitted as separate WWTPs, Town Creek and Grant Creek Treatment Trains will be treated as separate WWTPs in the LTMP with data from both sites used to determine pollutant removal efficiencies and plant inhibition thresholds. All Sills and Locals are monitored per IU Permit requirements and all POC's once per year. The City uses a Yearly Monitoring Plan. The Plan is followed as closely as possible weather permitting. If an SIU is not monitored in the month indicated, it is monitored as soon as possible. Uncontrollables are composite and grab samples at point in collection system that serves residential, commercial(including dentists and other medical), and any unpermitted non-Sills. Uncontrollable sampling,though not required,will be monitored annually. Salisbury will use the actual sludge that is disposed of as our sludge sampling requirement per our sludge disposal permit(WQ0001956)and EPA 503 regs. Grant Treatment Train GR — Grant Influent(sampled post preliminary processes,prior to residual side streams and primary process). GE — Grant Effluent(sampled at end of chlorine contact basin) GAB—Grant Aeration Basin(sampled prior to influent of secondary clarification,due to accessibility) GS- Grant Sludge to Disposal(digester sludge to disposal, sludge taken at end of belt press) Town Treatment Train TR—Town Influent(sampled post preliminary processes,prior to residual side streams) TE—Town Effluent (sampled at end of chlorine contact basin) TAB 1 —Town Aeration Basin#1 (sampled at effluent end of aeration basin) TAB2—Town Aeration Basin#2(sampled at effluent end of aeration basin) TS -Town Sludge to Disposal( digester sludge to disposal, sludge taken at end of belt press) Final Effluent(Yadkin Effluent) YE —Grant and Town Creek Treatment Trains chlorinated combined effluents are dechlorinated then composite sampled prior to the cascade. Industries -Discharge to Grant & Town Creek Treatment Train AFS -Agility Fuel Systems(Town) AKN—AkzoNobel(Grant) FRE—Freirich Foods(Grant) HBD—HBD, Industries(Town) HIT—Hitachi Metals(Grant) IPC—Innospec Performance Chemicals(Grant) CSP—CSP Composites(Formerly Magna Composites)(Grant) THR—Thorlo(Town) Local SRN and Uncontrollables PCA—Packing Corporation of America(Local permit) SPO—SupplyOne(formerly Packaging Services of Carolina,Inc.) (Local permit) CHG-China Grove (Satellite-uncontrollable) LDS-Landis (Satellite-uncontrollable) GRQ-Granite Quarry(Satellite-uncontrollable) FAI-Faith (Satellite-uncontrollable) ESP-East Spencer(Satellite-uncontrollable) SPR-Spencer (Satellite-uncontrollable) Grant Creek Treatment Train Sampling Points and Frequency Sample Location Sample ID Description Sample Type Sample Frequency Grant Influent GR Influent from collection 24 Hr Composite system, sampled post GR and GE sampled preliminary processes, quarterly on a prior to residual side workday and per streams and primary NPDES requirement process Grant Aeration GAB Effluent from aeration Grab GAB samples Basin basin, sampled prior to collected once every influent of secondary 6 months. clarification,due to accessibility Grant Effluent GE Effluent from treatment 24 Hr Composite train, sampled at end of chlorine contact basin Grant Sludge to GS Digester sludge to Grab GS samples collected Disposal disposal, sludge taken at per sludge permit end of belt press WQ0001956 and 503 regulations Page 2 Town Creek Treatment Train Sampling Points and Frequency Sample Location Sample ID Description Sample Type Sample Frequency Town Influent TR Influent from collection 24 Hr Composite system, sampled post TR and TE sampled preliminary processes, quarterly on a prior to residual side workday and per streams NPDES requirement Town Aeration TAB 1 & Effluent from aeration Grab Basin TAB 2 basins, sampled TAB 1 &2 samples separately at the effluent collected once every end of each aeration 6 months. basin Town Effluent TE Effluent from treatment 24 Hr Composite train, sampled at end of chlorine contact basin Town Sludge to TS Digester sludge to Grab TS samples collected Disposal disposal, sludge taken at per sludge permit end of belt press WQ0001956 and 503 regulations City of Salisbury WWTP Sampling Point and Frequency Code Name Description Type Frequency YE Combined Grant and Town Creek 24 hr composite sampled quarterly on Effluent Treatment a workday and per Trains dechlorinated NPDES requirement combined effluents Note: Dechlorinated combined effluent YE(TE+GE=YE)will be analyzed for each of the POCs but will not be used in the calculation of pollutant removal efficiencies,plant inhibition thresholds or in the calculation of uncontrollable loadings. Page 3 Pollutants of Concern(POC): Reason for Inclusion POC List NPDES 503 Sludge SIU Permit Limit Flow X X X BOD X X COD X TSS X X NH3-N X X NO2+NO3 X TKN X X Total Phosphorus X X Total Cyanide X X Oil&Grease X % Solids X As X Cd X X Cr X Cu X X X Pb X X Hg X Mo X Ni X X Se X Ag X X X Zn X X A Contract lab analyzes the following parameters: Detection Limits: Pollutant DL,mg/I Pollutant DL,pg/1 1 Pollutant DL,pg/1 Mercury 0.0002 Arsenic 2.0 Selenium 5.0 (method 245.1) Nitrite+Nitrate 0.3 Cadmium 0.50 Oil&Grease 5 Lead 2.0 Hardness 1 Silver 1.0 Grant Creek Regional Wastewater Laboratory# 112 analyzes the following parameters: Detection Limits: Pollutant DL,mg/1 Pollutant DL,pg/1 BOD 2 Chromium 5 COD 10 Copper 2.0 TSS 2.5 Molybdenum 10 TKN 1 Nickel 5 NH3-N 0.1 Zinc 10 Total Phosphorus 0.01 Total Cyanide 0.01 %Solids 25 * Detection Limits are typical but may vary with changes in sample matrix or analytical conditions. **All POCs are 24 hour composites with the exception of Cyanide and Oil&Grease which are grabs. Page 4 a 15 8 o bn a, rl con et "ci X XXX XXXXXXXX 56 a E un a N M O N Z AAc� r, Z o DC7 0 STs �. ° � bno ... „ bn ° Fp) C) H NaU � v� � 0000-4 00 NI P� Z o 0 o °