HomeMy WebLinkAboutWQCS00309_Compliance Evaluation Inspection_20180416 ROY COOPER arVeMOirMICR::S.REGAN . . Secredevy Water Resources LINDA CULPEPPER wivOtOMe+rriru.awui€r litivinDitector April 16, 2018 Ron Istre, Utilities Superintendent Town of Southern Pines 140 Memorial Park Ct. i2ECEIVEDIDEA NWDWR Southern Pines, NC 28387 PR 2 6 2018 SUBJECT: Compliance Inspection Report Waterg Resources Permitting Southern Pines Collection System Collection System Permit No. WQCS00309 Moore County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Southern Pines Collection System on 3/28/2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Collection System Permit No. WQCS00309. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. State of North Carolina I Environmental Quality I Water Resources 225 Green Street,Suite 714,Fayetteville,NC 28301-5043 910-433-3300 If you should have any questions, please do not hesitate to contact Hughie White with the Water Quality Regional Operations Section in the Fayetteville Regional Office at 910-433-3300 or via email at hughie.white@ncdenr.gov. Sincerely, J. Trent Allen, Regional Supervisor • Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Fayetteville Regional Office (HW) PERCS Unit State of North Carolina I Environmental Quality I Water Resources 225 Green Street,Suite 714,Fayetteville,NC 28301-5043 910-433-3300 • Compliance Inspection Report Permit: WQCS00309 Effective: 04/01/13 Expiration: 03/31/18 Owner: Town of Southern Pines SOC: Effective: Expiration: Facility: Southern Pines Collection System County:Moore 125 Se Broad St Region: Fayetteville Southern Pines NC 28387 Contact Person: Brent Lockamy Title: Phone: 910-692-1983 Directions to Facility: System Classifications: CS2, Primary ORC: Ronald J Istre Certification: 1002399 Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: NC0037508 Moore County-Moore County WPCF Inspection Date: 03/28/2018 Entry Time: 09:15AM Exit Time: 01:30PM Primary Inspector: Hughie White Phone: 910-433-3300 Ext.708 Secondary Inspector(s): Trent Allen Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: El Compliant 0 Not Compliant Question Areas: • Miscellaneous Questions • Performance Standards • Operation&Maint Reqmts ▪ Records I Monitoring&Rpting Reqmts • Inspections • Pump Station (See attachment summary) Page: 1 Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: All records and log books were very well organized and maintained. A copy of the collection system permit,spill response plan,sewer use ordinance,capital improvement plan and map of the collection system were all available for review. The annual 10%of line cleaning was met for the previous year. High priority lines are being inspected at least once per every six month period of time. Grease education materials are being disrtibuted as required.The rights-of-ways that were visited during this inspection are accessible in the event of an emergency. Also,the pump stations that were visited during this inspection appeared to be operated and maintained properly with very good housekeeping. • Page: 2 Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? 11000 What educational tools are used? Bill stuffers sent out four time per year Is Sewer Use Ordinance/Legal Authority available? • 000 Does it appear that the Sewer Use Ordinance is enforced? • 000 Is Grease Trap Ordinance available? • 000 Is Septic Tank Ordinance available(as applicable,i.e.annexation) 000 . List enforcement actions by permittee,if any,in the last 12 months Has an acceptable Capital Improvement Plan(CIP)been implemented? 111000 Does CIP address short term needs and long term\"master plan\"concepts? • 000 Does CIP cover three to five year period? • 000 Does CIP include Goal Statement? • ❑ ❑ ❑ Does CIP include description of project area? • 000 Does CIP include description of existing facilities? • 000 Does CIP include known deficiencies? • ❑ ❑ 0 Does CIP include forecasted future needs? • 000 Is CIP designated only for wastewater collection and treatment? ❑ • ❑ ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? • 000 If no,describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? • 000 #Does the sign include: Instructions for notification? 11000 Pump station identifier? • 000 24-hour contact numbers • ❑ ❑ 0 If no,list deficient pump stations #Do ALL pump stations have an"auto polling"feature/SCADA? • 000 Number of pump stations 18 Number of pump stations that have SCADA 18 Number of pump stations that have simple telemetry 0 Number of pump stations that have only audible and visual alarms 0 Number of pump stations that do not meet permit requirements 0 #Does the permittee have a root control program? • ❑ ❑ ❑ Page: 3 W ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ W000 00 000000000 0 0 ,7 i ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ i ❑❑ 002- .- 0000 • 0000 ❑ 0 iv 0 ca z0 ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ Z ❑ ❑ ❑ ❑ ❑ 000000000 0 ❑ 0 re } ■ ■ ■ ❑ ■ ■ ■ ■ ■ Y ■ ■ ❑ ME $ • • • • 0 • • • • 1111 III N_ g O C O N A d as C a E as c-- CO N O N Z N N a) n E C N a) d c a E E 2 a`> o. o' w a) a) ns u) CO a) f0 N `0 <,. o F• uE p. N E Z O O U >. d N C _Iii C) C (o T t p Oes (1) 0 a m N p 0. a7 c• N �' 0.)''' E a) C U �� 3 ami a) C' c E n a) n c )i c G) (.. °� c CO x d 0 E C. E o Q) a) .` 'y a c > a) (.. .2 d) co f0 a ..- >. °� a) O. N d u -o m o m o m L ai 'v E S..,' _o E t C G 3 a) U C (a .Q N U y _d C C-• a) C o$ u) a) U p .0 C y a N >. 7 a) C 3 C O C a n N an m £ rn N a) C .0 CT E a) c m E f0 C N .0 c Z L a) N C a) c a) �. O. E O �. 4- CN1 p. c N .ci a) C c Q7 C_ �. R f0 Cl 0 T O O E (NO N CO = a) N - c > O Q n �_ j y 0 m m o o o 0 o is U o E s a) E fO a) C c > u) aT N U p U C d a 0 (6 N 5+ c (� a) coCLam) a3 O. m 0. C Q) d as N U t>6 C 'C a — -C j, -C a c Cs. N E n E .N-... cd O y c E c N a) a) y .O 0' c j U (O C C C 0 cU) _ n , n a m aa) S :c o h CD aa) an v (0 (° a 3 y a) (ca a' m rn a) — c n d c c o = Y a) E m a) a m a ac Q a m 0 c '(a p a a) E a n E ' o a) N o o rn n c E c > m N ns > () co D 3 a c E c m o c a) m — a t N m c m to oo o U a) a n 'S o c o 0 o CC .0 N '3 Q m o) rn c_7,—> 0.§ Z E rn c°)i > m C) C c'' N U U p U 0) C y a) C C fo a) (O UCO �. .0 O '9 O U O a) p N .> '� QI 'c C c a) d N 'NOd .N.. O M a d a aa) a- a a 4Z) a a c C. — n d w m y N m m a) > 2 a c a O N a) N N N N CO a3 a) N a U N O N O c 0 -o 2 Z a) E 0 .S c co ; a) o v y o •c a) u? R c U N E % 6 a) o N E a) 0 a) a) C 0 •C a) N d Q 0 an N N >, a U c E A E c E m >N o c > •> o m rn y E a) m N r 1.> o c rs C N a) N a) (O Na's (6 N to N C O a a C N U C O U U CI- O E O. ~ a) (C fa a) O c M y O Z L U E c C o (o co a) O U >. (o N 0 .0 C C > o O > a) a) > a) 0 N a) U c E .c a rn p) rn n c ca a) p c 8 E. .o y as as U a7 > f0 y ae! c 'Z 0- N C ? N .a cat) .-0-5 —c C c N C . U N a7 m U C O N 'o C (n 'O — N 'NO` .O C c y N .t0.. .o. a .t0-. N a) O E 03 as CC C1 7 C .O w C 8 Q c o 07 .t... O a`) E as ' y j c_ a) a -op a) a) a) O C .c = o .c N E V (O (� O U T U .L.. a) — N .y a7 U .y E N N N N 2 as 0) >. m a j, U E 4! 2 (n C O 03 E - N co N m E N —. Q c c c C a) E N a) m u) N N an 0 y a) a) a) a) N Q I 2 N 0 d 2 O O L N a) L O — `) 2 N R L O O ik a U = < < Q < < k at < 2 0 0 < o O < c2a Q Q < I a Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling - 'Reason for Visit: Routine Response time • 0 0 0 Equipment list and spare parts inventory • 0 0 0 Access to cleaning equipment • 0 0 ❑ Access to construction crews,contractors,and/or engineers • ❑ 0 ❑ Source of emergency funds • ❑ ❑ ❑ Site sanitation and cleanup materials • ❑ ❑ ❑ Post-overflow/spill assessment • 0 0 0 Is a Spill Response Action Plan available for all personnel? • ❑ ❑ ❑ Is the spare parts inventory adequate? • ❑ 0 0 Comment: Records Yes No NA NE Are adequate records of all SSOs,spills and complaints available? I ❑ ❑ ❑ Are records of SSOs that are under the reportable threshold available? • 0 0 0 Do spill records indicate repeated overflows(2 or more in 12 months)at same location? ❑ ❑ IN ❑ If yes,is there a corrective action plan? ❑ ❑ II ❑ Is a map of the system available? • 0 0 0 Does the map include: Pipe sizes • ❑ ❑ ❑ Pipe materials • ❑ 0 0 Pipe location • 0 ❑ ❑ Flow direction • ❑ ❑ ❑ Approximate pipe age • ❑ ❑ ❑ Number of service taps • ❑ ❑ ❑ Pump stations and capacity • ❑ ❑ ❑ If no,what percent is complete? List any modifications and extensions that need to be added to the map #Does the permittee have a copy of their permit? • ❑ ❑ ❑ Comment: Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? • ❑ ❑ ❑ Are public notices and proof of publication available? • ❑ ❑ ❑ #Is an annual report being prepared in accordance with G.S.143-215.1C? • ❑ 0 0 #Is permittee compliant with all compliance schedules in the permits? ❑ ❑ II ❑ If no,which one(s)? Comment: PEE DEE ROAD - Page: 5 Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? • 000 Is it accessible in all weather conditions? • 000 #Is general housekeeping acceptable? M ❑ ❑ ❑ Are all pumps present? 10000 Are all pumps operable? 11000 Are wet wells free of excessive debris? M ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? M ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? • 000 Is"auto polling"feature/SCADA present? • 000 Is"auto polling"feature/SCADA operational? • 000 Is simple telemetry present? 00 • 0 Is simple telemetry operational? ❑ ❑ E ❑ Are audio and visual alarms present? • ❑ ❑ ❑ Are audio and visual alarms operable? • 000 Is the Pump station inspected as required? • 000 Are backflow devices in place? 000 • Are backflow devices operable? ❑ ❑ ❑ • Are air relief valves in place? 00011 Are air relief valves operable? 00011 # Is an emergency generator available? M ❑ ❑ ❑ Can the emergency generator run the pumps? 000 • Is the pump station equipped for quick hook-up? • 000 Is the generator operable? 000 • #Is fuel in tank and sufficient? 00011 Is the generator inspected according to their schedule? 000 • Is a 24-hour notification sign posted? • 0 0 0 Does it include: Instructions for notification? • 0 ❑ ❑ Pump station identifier? • 000 Emergency phone number U 0 ❑ ❑ Is public access limited? • 000 Is pump station free of overflow piping? 111000 Is the pump station free of signs of overflow? • 000 Are run times comparable for multiple pumps? yes Page: 6 w 000000000000000111 • • • 0 • 0 • • 1110 ❑ ❑ ❑ ❑ ❑ ,.- 0000000000 • • 00000000000000 ❑ ❑ ❑ ❑ ❑ a) en as z x ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ D ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ } o ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ❑ ❑ ■ ■ ■ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ■ ■ ■ ■ ■ •N 1 w C O N N a) a: a E n E co U) c 0 z U N a) • O- C Cl) Cr_ c c E `m L N d O CO C O 3 U ) 0 0 I— U to n, � 0 LL c E O o c a)O 8 a o NN c C O) cs. c' O •N a)N N Y L r.:: c...y E oU a R c. Na Y O 'C- aN O a) R 7 •- C 0 o) O �' aQ 2 cmc• n � `o nC a > o C o 'n a, a m ° x am o m cn O aR . i NoN a) 0 aQ Q c- N a �. N 0 fa o o c-.N d U O R O ' a) c--' R o' U c N oco .> 0 .00.. N CD O. •c) m m y R co .3) o. Q < C• g Cl) Cl) R s aa) Cv CR c d 3N : Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Is the pump station free of signs of overflow? • 000 Are run times comparable for multiple pumps? yes Comment: CAROPINES - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? 11000 Is it accessible in all weather conditions? • 000 #Is general housekeeping acceptable? • 000 Are all pumps present? 111000 Are all pumps operable? • 000 Are wet wells free of excessive debris? • ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? 11000 Are floats/controls for pumps/alarms operable? • 000 Is"auto polling"feature/SCADA present? • 000 Is"auto polling"feature/SCADA operational? • 000 Is simple telemetry present? 00 . 0 Is simple telemetry operational? 00110 Are audio and visual alarms present? • 000 Are audio and visual alarms operable? • ❑ ❑ ❑ Is the Pump station inspected as required? 111000 Are backflow devices in place? 000 • Are backflow devices operable? ❑ ❑ ❑ U Are air relief valves in place? ❑ ❑ ❑ • Are air relief valves operable? ❑ ❑ ❑ • # Is an emergency generator available? • 000 Can the emergency generator run the pumps? • ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ E ❑ Is the generator operable? • 000 #Is fuel in tank and sufficient? 111000 Is the generator inspected according to their schedule? • 000 Is a 24-hour notification sign posted? • 000 Does it include: Instructions for notification? • 000 Pump station identifier? • 000 Emergency phone number • 000 Page: 8 Permit: WQCS00309 Owner-Facility:Town of Southern Pines Inspection Date: 03/28/2018 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Is public access limited? • 0 0 0 Is pump station free of overflow piping? • ❑ ❑ 0 Is the pump station free of signs of overflow? • ❑ ❑ ❑ Are run times comparable for multiple pumps? yes Comment: Page: 9