HomeMy WebLinkAbout20171642 Ver 1_Grading & Storm Drainage Plan REV_20180320DEVELOPMENT DATA
OWNER/DEVELOPER:
CONTACT:
CMS HOMES, INC.
5250 HENDERSONVILLE RD.
FLETCHER, NORTH CAROLINA 28732
CAS SMITH
(828)684-1550
CIVIL ENGINEER:
ADVANTAGE CIVIL ENGINEERING, P.A.
SIDE SETBACK:
34 BIG BEAR TRAIL
REAR SETBACK:
ASHEVILLE, NORTH CAROLINA 28805
CONTACT:
MIKE LOVOY, P.E.
WASTEWATER TREATMENT:
(828) 545-5393
SURVEYOR:
ASSOCIATED LAND SURVEYORS & PLANNERS, PA
10+00
P.O. BOX 578
PIPE END
HORSE SHOE, NORTH CAROLINA, 28742
CONTACT:
CAMERON S. BAKER, PLS
PIPE END
(828) 890-3507
PROJECT DATA
INV. OUT 2158.39±
PIN:
9681-10-4506
ADDRESS:
NO ADDRESS ASSIGNED
DEED BOOK/PAGE:
087-SP/134
SITE AREA:
18.1 ACRES (789,202 SF)
ZONING:
RESIDENTIAL DISTRICT TWO RURAL (R2R)
SUBDIVISION DATA:
INV. IN 2169.85
SUBDIVISION TYPE:
MAJOR SUBDIVISION, RESIDENTIAL
FRONT SETBACK:
15' (LOCAL ROAD)
SIDE SETBACK:
10'
REAR SETBACK:
10'
WATER SUPPLY:
INDIVIDUAL WELL ON EACH LOT
WASTEWATER TREATMENT:
INDIVIDUAL SEPTIC SYSTEM ON EACH LOT
FIRE PROTECTION:
BY ALTERNATIVE MEASURES
NATURAL RESOURCES DATA:
SOILS:
SOIL GROUPS:
DISTURBED AREA:
DEVELOPMENT DENSITY:
PROJECT DENSITY TYPE:
IMPERVIOUS AREA ALLOWED:
POST -DEVELOPMENT IMPERVIOUS:
PRE -DEVELOPMENT IMPERVIOUS:
FUTURE IMPERVIOUS AREA ALLOWED
LANDSCAPE DATA:
STREET TREES REQUIRED:
STREET TREES PROVIDED:
BUFFER REQUIRED:
BUFFER PROVIDED:
EXISTING STORM
DRAINAGE (TYP.)
EXISTING STORM
DRAINAGE (TYP.)
Co; EdF; EwF; Ha; HyC; HyE; TeB
B; C; B/D
6.73 AC
0.94 UNITS/AC
LOW DENSITY
189,408 SF (24%)
±92,609 SF (11.73%)
±1,303 SF (0.002%)
±96,799 SF (12.27%) (SEE NOTE)
ALONG INTERNAL ROAD
1 LARGE DECIDUOUS TREE/50LF
OR, 1 SMALL DECIDUOUS TREE/40 LF
56 LARGE DECIDUOUS TREES
00 SMALL DECIDUOUS TREES
TYPE "62" ALONG N. CLEAR CREEK RD.
30' WIDE
2 LARGE DECIDUOUS TREES/100 LF
3 SMALL DECIDUOUS TREES/100 LF
5 LARGE EVERGREEN TREES/100 LF
12 SMALL EVERGREEN TREES/100 LF
3 LARGE DECIDUOUS TREES/100 LF
4 SMALL DECIDUOUS TREES/100 LF
7 LARGE EVERGREEN TREES/100 LF
16 SMALL EVERGREEN TREES/100 LF
PROPOSED PERMANENT
DITCH (PD1) @ 3.0%
AND LINED WITH NAG
SC250 OR APPROVED
EQUIVALENT (CO TO Al)
(SEE DETAIL)
UNNAMED TRIBUTARY
TO HARPER'S CREEK
Al
STRUCTURE TABLE
(INVERTS BASED ON 2D LENGTH TO INSIDE EDGES)
STRUCTURE
STATION
STRUCTURE DETAILS
DESCRIPTION
AO
0+00
INV. OUT 2111.77±
PIPE END
Al
0+64
INV. IN 2115.11
CONCRETE HEADVI
BO
10+00
INV. OUT 2132.86±
PIPE END
B1
10+23
INV. IN 2134.93
PIPE END
CO
10+00
INV. OUT 2158.39±
PIPE END
C1
10+28
INV. IN 2160.33
PIPE END
DO
10+00
INV. OUT 2168.84±
PIPE END
D1
10+24
INV. IN 2169.85
PIPE END
EO
10+00
INV. OUT 2157.65±
PIPE END
E1
10+31
INV. IN 2160.85
PIPE END
FO
10+00
INV. OUT 2142.39±
PIPE END
F1
10+24
INV. IN 2144.97
PIPE END
GO
10+00
INV. OUT 2132.97±
PIPE END
G1
10+28
INV. IN 2135.21
PIPE END
HO
10+00
INV. OUT 2123.74±
PIPE END
H1
10+29
INV. IN 2126.06
PIPE END
10
10+00
INV. OUT 2116.55±
PIPE END
11
10+33
INV. IN 2117.38
PIPE END
PROPOSED STORM DRAINAGE
(SEE STORMWATER PLAN)
�J
PIPE TABLE
(SLOPES BASED ON 2D LENGTH TO INSIDE EDGES)
PIPE NAME
SIZE
LENGTH
SLOPE
MATERIAL
Al -AO
84"
59.44'
5.62%
CMP
131 BO
18"
23.38'
8.85%
HDPE
C1 -CO
15"
28.06'
6.91%
HDPE
D1 -D0
15"
24.00'
4.21%
HDPE
E1 -EO
15"
31.00'
10.32%
HDPE
F1 -FO
18"
24.00'
10.75%
HDPE
G1 -GO
18"
28.00'
8.00%
HDPE
H1 -HO
18"
29.00'
8.00%
HDPE
11-10
18"
33.49'
2.48%
HDPE
LEGEND
STORM DRAINAGE PIPE
EXISTING CONTOURS
PROPOSED CONTOURS
00
NOTES
1. SEE GRADING, EROSION CONTROL, AND STORM DRAINAGE DETAIL
SHEETS FOR ALL GENERAL NOTES. CONTRACTOR RESPONSIBLE
FOR INCLUSION OF DETAILS SHEETS WITH ALL PLANS.
2. NO PORTION OF THIS PROJECT LIES WITHIN THE 100 -YR FEMA
FLOODPLAIN.
3. SOIL TYPES B, C. B/D.
4. SEPTIC DRAIN FIELD AND REPAIR AREAS SHALL BE MARKED
ON-SITE AND SHALL REMAIN UNDISTURBED DURING PROJECT
CONSTRUCTION.
Know what's below.
Call before you dig.
N. CLEAR CREEK RD.
I \ PROPOSED PERMANENT I
DITCH (PD4) @ 7.88%
\ \ - 2190 AND LINED WITH NAG
SC250 OR APPROVED I
PROPOSED PERMANENT \ \ PROPOSED WATER WELL EQUIVALENT (DO TO E1)
DITCH (PD3) ® 11.23% (TYP.)(SEE UTILITY PLAN) I (SEE DETAIL) I I
AND LINED WITH NAGPROPOSED PERMANENT
d'
SC250 OR APPROVED \ O I - DITCH (PD7) ® 8.0%
EQUIVALENT (DRIVEWAY TO D1) \ I ' AND LINED WITH NAG /
PROPOSED PERMANENT
(SEE DETAIL) _ 180 PROPOSED 1� SC250 OR APPROVED I
15" HDPE 2 BUILDING DITCH (PD5) @ 15.24% / i
\ EQUIVALENT (SEE DETAIL)
(CULVERT D) FOOTPRINT AND LINED WITH NAG
2>> \ (TYP.) SC250 OR APPROVED
LottI EQUIVALENT (EO TO F1)
\ \ 1._58 AC, es I j 3/ (SEE DETAIL)
O.i7>z .Acre Lot /- / / \
68,70.80 SF 37 745 09 F
SUBJECT
PROPERTY
VICINITY MAP
(NOT TO SCALE)
0.72 Ace _ 18 HDPE PROPOSED PERMANENT
/ / 30' AQUATIC
39,230.8 SF/ 21 0 18" HDPE / / / (CULVERT H) DITCH (PD8) ® 5.80% BUFFER TO BE
PROPOSED PERMANENT (CULVERT F) I / AND LINED WITH NAG/'/i
/ � / / �j/ , PROTECTED (TYP.)
_ DITCH (PD2) @ 4.30% / C SC250 OR APPROVED
PROPOSED PERMANENT AND LINED WITH NAG (,n; - EQUIVALENT (SEE DETAIL)
DITCH (PD A) @ 7.2% - SC250 OR APPROVED ; '• i ' • j/ / / WETLAND (TYP)
EQUIVALENT (DRIVEWAY TO Cl)/ -,
AND LINED WITH NAG /
/ 6�A
SC250 OR APPROVED (SEE DETAIL) � � / ' 8 % /� EQUIVALENT (SEE DETAIL) / 16 , 2 '/N I / Clio
UNNAMED TRIBUTARY TO
�� HARPER CREEK (TYP )
BO
WETLAND TYP
j 15"DPE
7,�I CUL RT
\ � ,� I I ��%��/ � i/�� t • i /���i � / I / ///%�/ / //// // % / ///%/j � �^o � \ 1. i/ l 11 ,
IC1Ul
- - =�/�� � ��, � •�%�i ,%� i%%!i�� y i �. ���//�, / 18' HPE
F1 FO ( LT )
o o
GO H1 /'
o
HO
- - - - -
� MOSS DRIVE N 2
(45' PUBLIC R/W) o
131 o o �� � 10 ,0
t /
f �• -
-
I � � it DO E1 - I
� .�• 18" HDPE � EO
\ (CULVERT B)
f I
15 HDPE
I
% I /
(CJJLVERT E)
PROPOSED PERMANENT
DITCH (PD9) 0 5.80%
AND LINED WITH NAG
• SC250 OR APPROVED
EQUIVALENT (SEE DETAIL)
PROPOSED PERMANENT
\ \ \ \ \ \ \ DNDHLINEDI WITH NAG % / / / / // A
84" CMP \
/ /
(CULVERT A) % \ \ \ \ \ \ \ \ EQUIVALENT (SEED DETAIL) I 17 I / / / / / / III 1 111111, / / / /// ///
1111
\ / PROPOSED PROPOSED PERMANENT / 111 I I I I I I I I I I I I
0� 17-= _-� / // DRIVEWAY DITCH (PD6) 8.92% 1111111 I I
(TYP.) 11�cie111
AO %� \ -_ %/%/// / / AND LINED WITH NAG �347/.435F�� / l l 11l 11 11 11l 111
N SC250 OR APPROVED
0.64 Acre / // l Lot �� rl� l / /
\ % /%/% 279�+0.995F / \ \\\\�\\\� / EQUIVALENT (FO TO G1)
///%// l / 0.64Acre l j 11 \ \\\ \\\ \ ,Ir�1 (SEE DETAIL) IIIIIIIIIIII / / / /
/
/ / 11 111111 / iii 11 11 l 111 /
r�r/ �
i'i'i
PROPOSED PERMANENT
PIP DITCH (PD15) ®3.0% \ \\\ \\\X\' / .mc) / IIIIi'll I / / / I� II I
AND LINED WITH NAG �� / / / / N \ ry 1 1 1 I 1 I /
SC250 OR APPROVED \ \ \ I / / III I 30 AQUATIC BUFFER TO I
60' \ EQUIVALENT (SEE DETAIL) J-
\ UNNAMED TRIBUTARY
TO HARPER CREEK
30' AQUATIC BUFFER TO
BE PROTECTED (TYP.)
NOTE: ANY FUTURE DEVELOPMENTS ON INDIVIDUAL LOTS
RESULTING FROM THIS DEVELOPMENT PROJECT SHALL
OBTAIN A HENDERSON COUNTY STORMWATER PERMIT FOR
ADDITIONAL PROPOSED IMPERVIOUS SURFACES.
NOTE: SEE DETAILS FOR EROSION AND SEDIMENTATION
CONTROL AND STORMWATER DISCHARGES SELF-INSECTION
AND REPORTING REQUIREMENTS.
NOTE: HARPER CREEK AND THE UNNAMED TRIBUTARY
ADJACENT TO N. CLEAR CREEK ROAD ARE DEPICTED PER
SURVEY. THE WETLANDS AND ASSOCIATED AQUATIC BUFFER
AS SHOWN ARE ESTIMATED. A FINAL JURISDICTIONAL
DETERMINATION BY THE US ARMY CORPS OF ENGINEERS IS
IN PROGRESS TO DEFINE THE WETLAND BOUNDARIES. A FINAL
WETLAND SURVEY WILL BE CONDUCTED AND INCORPORATED
INTO THE PROJECT DESIGN. ALL PROJECT CONSTRUCTION
ACTIVITIES RELATED TO REGULATED WATERS AND ASSOCIATED
AQUATIC BUFFERS SHALL BE BASED ON ACTUAL LOCATIONS
AND RELATED SURVEY DATA.
PROPOSED DRAINAGE
SWALE BETWEEN
HOUSES (TYP.)
NOTE: LOCATE AND FLAG THE AQUATIC BUFFER BOUNDARIES
PRIOR TO INITIATING ANY LAND DISTURBING ACTIVITY.
NOTE: A TROUT BUFFER WAIVER IS REQUIRED FROM
THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL
QUALITY, LAND QUALITY SECTION, PRIOR TO ANY LAND
DISTURBANCE WITHIN THE AQUATIC BUFFER.
- / �� I I I BE PROTECTED (TYP.) I III I I I I I I
/CIDI y '� iIII III I I I
/ PROPOSED PERMANENT
DITCH (PD10) @ 2.0% / / / _ TOP OF BANK (TYP) -�/ I I I I I I I
AND LINED WITH NAG
PROPOSED PERMANENT SC250 OR APPROVED -4
DITCH (PD12) ® 2.0%
AND LINED WITH NAG
SC250 OR APPROVED
EQUIVALENT (SEE DETAIL)
PROPOSED PERMANENT
DITCH (PD13) ® 2.0%
AND LINED WITH NAG
SC250 OR APPROVED
EQUIVALENT (SEE DETAIL)
PROPOSED SEPTIC
DRAIN FIELD (TYP.)
(SEE UTILITY PLAN)
PROPOSED SEPTIC
REPAIR AREA (TYP.)
(SEE UTILITY PLAN)
PROPOSED PERMANENT
DITCH (PD11) ® 2.0%
AND LINED WITH NAG
SC250 OR APPROVED
EQUIVALENT (SEE DETAIL)
EQUIVALENT (SEE DETAIL)
HARPER CREEK (TYP)
��ill II ►�,�
I
GRADING & STORM
DRAINAGE PLAN
GRAPHIC SCALE
60 0 30 60 120 240
( IN FEET )
1 inch = 60 ft.
4�:oF E sAR�lr ;
-
SEAL _
- 0 897 -
8
GINEE:
Z
0
U
Z
ZW
W
Z z
W
Q
W w
SOU
U j<
W z
Q
Q W C)
O
O J 0
0a
V
Q z Z
W Q 0
o�
Q DC Q U
U
Y
W w0
E Z
U
cal
W
Q=
W U
J U
U W
zLL
0 0 0
N N N
Lo L0 �
i
Ld
0 0
w
O J
O Q
z
w 0
w v
- - o
LJz �
� w
3: :2
:2 O
0- 0 Q
3: O
U) w
46 w o
Q
O
0 0
z U
z o
z ~
o Q
w w
n o z
o Q
D_ cn w
W =) o
01 11� lh�
W w w
w w w
cn cn cn
z z z
O O o
w w w
DO, -)
o- rr
PROJECT NO.: 1 765
DRAWN BY: UAG
DATE: 07-25-17