HomeMy WebLinkAboutSW5180301_Plans_20180424S 77°04'23" E 483.93' TOTAL417.52'66.41'S 84°53'36" E152.22'S 16°2
8
'
0
8
"
W
528.42'L-1S 04°03'01" E219.37'84.46'134.91''RRSEIPEIPEIPEIPEIPNIPNIPC - 1EX. WATER LINEEX. EASEMENTEX. OVERHEAD ELECTRIC LINEEX. ADJACENT OWNERSEX. PROPERTY LINEEX. SANITARY SEWEREX. CHANNEL/STREAMEX. CHAIN LINK FENCEEX. SOIL LINEEX. ROAD CENTERLINEEX. TREE LINE324EX. MAJOR CONTOUR (5')EX. MINOR CONTOUR (1')LEGENDEX. RIGHT-OF-WAYEX. CHANNEL/STREAM BUFFER325EXISTING CONDITIONS &DEMOLITION PLANC-22NOTES1. BOUNDARY AND TOPOGRAPHIC DATA PROVIDED BY CAWTHORNE,MOSS & PANCIERA, P.C. ON APRIL 07, 2017.2. NO PORTION OF THIS PROPERTY LIES WITHIN A FEMA DESIGNATED100-YEAR FLOOD HAZARD AREA PER FEMA PANEL 3720186400K DATEDAPRIL 16, 20133. SURFACE WATERS ARE PRESENT WITHIN THE PROJECT AREA.STREAM AND WETLAND DELINEATION PERFORMED BY CAROLINAECOSYSTEMS, INC. AND LOCATED BY CAWTHORNE, MOSS & PANCIERA,P.C.4. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE AREPRESENTATION OF ALL UTILITIES WITHIN THE PROJECT EXTENT.UNDERGROUND UTILITY LOCATIONS, IF SHOWN ON THE PLANS, AREBASED UPON THE BEST AVAILABLE INFORMATION AND SHOULD BECONSIDERED ONLY AS APPROXIMATE. WHERE CONFLICTS OCCUR,THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO BEGINNINGCONSTRUCTION.5. THE CONTRACTOR SHALL CALL THE NORTH CAROLINAONE-CALL-CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING WORK.6. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ALLUTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHENOPERATING AROUND EX. UTILITIES.7. THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR THEREPAIR OF ANY EX. UTILITIES DAMAGED DURING CONSTRUCTION.8. THIS PLAN IS NOT INTENDED AS A SUBSTITUTE FOR THE PERSONALINVESTIGATION, INDEPENDENT INTERPRETATION, AND JUDGEMENT OFTHE CONTRACTOR.9. THE CONTRACTOR SHALL CONTACT THE ENGINEER AND THE COUNTYA MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO THE BEGINNING OFCONSTRUCTION. CONNECTION TO THE EXISTING UTILITIES SHALL BEPERFORMED BY THE CONTRACTOR UNDER THE SUPERVISION OF THECOUNTY AND THE ENGINEER'S REPRESENTATIVE.11. THE CONTRACTOR SHALL KEEP THE ENGINEER INFORMED RELATIVETO THE PROGRESS OF THE CONSTRUCTION. THE ENGINEER SHALLOBSERVE CONSTRUCTION ACTIVITIES AS REQUIRED BY NORTHCAROLINA GENERAL STATUTES 130A - 317. FAILURE OF THECONTRACTOR TO KEEP THE ENGINEER INFORMED MAY REQUIREUNCOVERING OF WORK TO VERIFY COMPLIANCE WITH PLANS ANDSPECIFICATIONS. ANY COST ASSOCIATED WITH UNCOVERING WORKAND/OR VERIFYING COMPLIANCE SHALL BE BORNE BY THECONTRACTOR.12. ALL EXCAVATED MATERIAL SHALL BE DISPOSED OF IN A LAWFULMANNER.SOIL TYPESCeB2 - CECIL CLAY LOAM, 2 TO 6 PERCENT SLOPES, MODERATELY ERODEDHeB - HELENA SANDY LOAM, 2 TO 6 PERCENT SLOPESWeC - WEDOWEE SANDY LOAM, 6 TO 10 PERCENT SLOPESCURVE TABLECURVE LENGTH RADIUS CHORD BEARINGC-1 417.66' 2006.66' 416.90'N 81° 22' 38" WLINE TABLELINE LENGTH BEARINGL-1 11.34' S 85° 54' 46" WCALL 48 HOURS BEFOREYOU DIGNORTH CAROLINAONE-CALL CENTER1-800-632-49490404020SCALE: 1 INCH = 40 FEETNEX. ASPHALT(TO BE REMOVED)EX. EDGE OF PAVEMENT(TO BE REMOVED)EX. FENCE(TO BE REMOVED)EX.CONCRETEPADEX. 50' TAR/PAMLICO RIVERBUFFER FROM TOP OF BANKEX. 50' TAR/PAMLICO RIVERBUFFER FROM TOP OF BANKEX. STREAMEX. CREEKCeB2WeCHeBHeBWeCVARIABLE WIDTHGREENWAY / UTILITYEASEMENTP.B. 2010, PG. 172TOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTEX. SANITARY SEWERMANHOLETOP = 370.83'INV. IN = 362.52'INV. OUT = 362.23'EX. SANITARY SEWER MANHOLETOP = 375.32'INV. IN = 366.06'INV. OUT = 364.15'OAK RIDGE ROAD
60' PUBLIC RIGHT-O
F
-
W
A
YN/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270N/FANDREW W. &KAITLYN A. TROTTERD.B. 1975, PG. 943P.B. 7, PG. 58-59PIN# 1865-66-2297N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 58-59PIN# 1865-66-2472N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396PIN# 1865-66-2587N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 57PIN# 1865-66-3841N/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270TOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTPERKINSON WAY40' PUBLICRIGHT-OF-WAYEX. SANITARY SEWER MANHOLETOP = 396.07'INV. = 390.10'EX. SANITARY SEWER MANHOLETOP = 397.12'INV. = 391.15'ABANDONED EX. SANITARYSEWER MANHOLEEX. CONCRETEPADTOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTTOWN OF FRANKLINTON 20'SANITARY SEWER EASEMENT18" RCPINV. IN = 389.19'EX. FENCE AND EX.PARKING ENCROACHMENTEX. CURB & GUTTER(TYP.)EX. HYDRANTAPPROX. LOCATION OFEX. 16" WATERLINE(DEPTH UNKNOWN)EX. UTILITY POLE(TYP.)EX. FIBER OPTIC MARKER(TYP.)EX. TREELINE(TYP.)NC HWY 56 (E GREEN ST)60' PUBLIC RIGHT-OF-WAYEX. SANITARY SEWER LINE (TYP.)(SIZE AND MATERIAL UNKNOWN)EX. OVERHEAD POWER LINE(TO BE REMOVED/RELOOATED)
414239384037353634111210132928273031323323202419222125265261437981716141518SITE PLANC-440404020SCALE: 1 INCH = 40 FEETNSUMMARY INFORMATIONDEVELOPMENT NAME: CRAWFORD TOWNESSTREET ADDRESS: NC HWY 56 (E GREEN ST)PIN NUMBER(S): 1865-66-0607TOTAL AREA: 7.15 ACZONING DISTRICT: MIXED USE DISTRICT (MUD)SETBACKS:FRONT: 25'SIDE: 50'REAR: 50'JURISDICTION: FRANKLINTONPROPOSED USE: TOWNHOMESPROPOSED BUILDING HEIGHT: LESS THAN 30'MINIMUM HORIZONTAL BUILDING SEPARATION: 30'PROPOSED UNITS: 42PROPOSED DENSITY: 6.1 UNITS/ACREPARKING REQUIRED: 2 SPACES FOR EACH DWELLING UNIT PLUS 1VISITOR SPACE FOR EACH 4 DWELLING UNITS = 2 X 42 + 42 / 4 = 95PARKING PROVIDED: 95 (11 VISITOR)MAIL KIOSK PARKING: 2 (1 ADA VAN ACCESSIBLE)WATER SUPPLY WATERSHED: NONEDEVELOPER:CROSSWIND DEVELOPMENT, INC.7201 CREEDMOOR ROAD, SUITE 147RALEIGH, NC 27613919.258.2430ENGINEER:FLM ENGINEERING, INC.PO BOX 91727RALEIGH, NC 27675919.610.1051NOTES1. PROPOSED ADA STALLS AND AISLES SHALL HAVE SLOPES NOSTEEPER THAN 1:48 (2%) IN ALL DIRECTIONS.2. PROPOSED ACCESSIBLE ROUTES SHALL HAVE RUNNING SLOPESNO STEEPER THAN 1:20 (5%) AND CROSS SLOPES NO STEEPERTHAN 1:48 (2%),3. THE PRIVATE ROAD SHALL REQUIRE AN NCDOT DRIVEWAY PERMITAND SHALL BE 26'-WIDE, FACE OF CURB TO FACE OF CURB, WITHINA VARIABLE WIDTH ACCESS AND UTILITY EASEMENT.4. ALL TOWNHOMES SHALL HAVE FRANKLIN COUNTY WATER ANDSEWER SERVICE. WATER SHALL BE ACCESSED TO THE NORTHFROM NC HWY 56 (E GREEN ST) AND SEWER SHALL BE ACCESSEDTO THE SOUTH FROM THE EXISTING SANITARY SEWER EASEMENT.THE PLANS SHALL BE APPROVED BY FRANKLIN COUNTY, THE MAINEXTENSIONS APPROVED BY NCDEQ, AND THE RIGHT-OF-WAYENCROACHMENT APPROVED BY NCDOT.5. ALL DIMENSIONS ARE TO FACE OF CURB.6. ALL RADII ARE 5' UNLESS OTHERWISE NOTED.NC HWY 56 (E GREEN ST)60' PUBLIC RIGHT-OF-WAYOAK RIDGE ROAD
60' PUBLIC RIGHT-O
F
-
W
A
Y PERKINSON WAY40' PUBLIC RIGHT-OF-WAYTOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTEX. STREAM(TYP.)EX. VARIABLE WIDTHGREENWAY/UTILITYEASEMENT50' SID
E
Y
A
R
D
S
E
T
B
A
C
K
50' SID
E
Y
A
R
D
S
E
T
B
A
C
K50' REAR YARD SETBACK25' FRONT YARD SETBACKR200'26'19' (TYP.)9' (TYP.)PROP. 24" CURB& GUTTER (TYP.)EX. SANITARY SEWERMANHOLE (TYP.)APPROX. LOCATIONEX. 16" WATER LINE(DEPTH UNKNOWN)SEE INSET A,THIS SHEET1314121414161230' (TYP.)R15'R15'PROP. 10' X 70' SIGHTTRIANGLE (TYP.)PROP. 6.5' SIDEWALKALONG PARKING STALLSPROP. 4' WALK FROMBUILDING TOSIDEWALK (TYP.)PROP. STORMWATERCONTROL MEASUREPROP. 535 LF 26'-WIDE, FACE TO FACE,PRIVATE ROAD IN VARIABLE WIDTHPUBLIC ACCESS AND UTILITYEASEMENTEX. PROPERTY LINELEGENDEX. RIGHT-OF-WAYEX. EASEMENTEX. ADJACENT OWNERSEX. ROAD CENTERLINEEX. CHANNEL/STREAMEX. CHANNEL/STREAM BUFFEREX. CHAIN LINK FENCEEX. OVERHEAD ELECTRIC LINEEX. WATER LINEEX. SANITARY SEWEREX. STORM SEWERPROP. EASEMENTPROP. SETBACK LINEPROP. LOT LINESEX. FENCE AND EDGE OFASPHALT PAVEMENTEX. DRIVEWAY TOBE CLOSEDEX. TREE LINEEX. CONCRETE PADN/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 57PIN# 1865-66-3841N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396PIN# 1865-66-2587N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 58-59PIN# 1865-66-2472N/FANDREW W. &KAITLYN A. TROTTERD.B. 1975, PG. 943P.B. 7, PG. 58-59PIN# 1865-66-2297N/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270ABANDONED EX. SANITARYSEWER MANHOLE (TYP.)EX. SANITARY SEWER LINE (TYP.)(SIZE AND MATERIAL UNKNOWN)LOT SUMMARYLOT NO.AREA (SQ. FT)12,42821,37531,37541,37551,37562,83172,83181,37591,375101,375111,375122,831132,831141,375151,375161,375171,375182,687192,428201,375211,375221,375231,375242,831252,831261,375271,375281,375291,375302,831312,831321,375331,375341,375351,375362,831372,831381,375391,375401,381411,436422,933PROP. RETAININGWALL (BY OTHERS)PROP. DUMPSTER &ENCLOSURE11'9'18.5'PROP. 5' SIDEWALKFLUSH TOP OFCURBPROP. MAILKIOSK PADPER KIOSKINSTALLERINSET ASCALE: 1" = 20'11'10'10'PROP. ADA SIGNAGE WITHVAN ACCESSIBLE SIGNPROP. 4' TALL BLACKALUMINUM FENCE TOSURROUND SCMSIDEWALK SHALL BEFLUSH AT TRANSITION TOPAVEMENT WITH (1) 2'X4'TRUNCATED DOME PANELAT EACH TRANSITIONPROP. VARIABLE WIDTHPUBLIC ACCESS ANDUTILITY EASEMENTPROP. 20'FRANKLIN COUNTYSANITARY SEWEREASEMENTPROP. VARIABLE WIDTHPUBLIC ACCESS ANDUTILITY EASEMENTR48'R28'R5'R5'R5'R5'R5'R5'R5'R5'R5'555
414239384037353634111210132928273031323323202419222125265261437981716141518UTILITY PLANC-550404020SCALE: 1 INCH = 40 FEETNNC HWY 56 (E GREEN ST)60' PUBLIC RIGHT-OF-WAYOAK RIDGE ROAD
60' PUBLIC RIGHT-O
F
-
W
A
Y PERKINSON WAY40' PUBLIC RIGHT-OF-WAYTOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTEX. VARIABLE WIDTHGREENWAY/UTILITYEASEMENT50' SID
E
Y
A
R
D
S
E
T
B
A
C
K
50' SID
E
Y
A
R
D
S
E
T
B
A
C
K50' REAR YARD SETBACK25' FRONT YARD SETBACKEX. SANITARY SEWERMANHOLE (TYP.)APPROX. LOCATIONEX. 16" WATER LINE(DEPTH UNKNOWN)PROP. STORMWATERCONTROL MEASUREPROP. VARIABLEWIDTH PUBLICACCESS AND UTILITYEASEMENTEX. PROPERTY LINELEGENDEX. RIGHT-OF-WAYEX. EASEMENTEX. ADJACENT OWNERSEX. ROAD CENTERLINEEX. CHANNEL/STREAMEX. CHANNEL/STREAM BUFFEREX. CHAIN LINK FENCEEX. OVERHEAD ELECTRIC LINEEX. WATER LINEEX. SANITARY SEWEREX. STORM SEWERPROP. EASEMENTPROP. SETBACK LINEPROP. LOT LINESEX. FENCE AND EDGE OFASPHALT PAVEMENTEX. DRIVEWAY TOBE CLOSEDEX. TREE LINEEX. CONCRETE PADN/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 57PIN# 1865-66-3841N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396PIN# 1865-66-2587N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 58-59PIN# 1865-66-2472N/FANDREW W. &KAITLYN A. TROTTERD.B. 1975, PG. 943P.B. 7, PG. 58-59PIN# 1865-66-2297N/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270ABANDONED EX. SANITARYSEWER MANHOLE (TYP.)PROP. SANITARY SEWERPROP. STORM SEWERPROP. WATER LINEPROP. WATER METERPROP. GATE VALVEPROP. FIRE HYDRANT ASSEMBLYWITH GATE VALVE AND TEEPROP. SEWER CLEANOUTWATER MAIN CONSTRUCTION NOTES1. ALL WATER DISTRIBUTION CONSTRUCTION TO BE IN ACCORDANCEWITH FRANKLIN COUNTY PUBLIC UTILITIES STANDARDS ANDSPECIFICATIONS FOR WATER AND SEWER.2. CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLINCOUNTY PUBLIC UTILITIES.3. EXISTING MAINS ARE SHOWN TO THE EXTENT POSSIBLE AND AREGENERALLY NOTED "APPROXIMATE LOCATION, DEPTH UNKNOWN". ITIS THE RESPONSIBILITY OF THE CONTRACTOR TO ACCURATELYLOCATE EXISTING FACILITIES BY DIGGING A TEST PIT TO VERIFYEXISTING MAIN LOCATION, SIZE, DEPTH, AND MATERIAL.4. THE CONTRACTOR SHALL OBTAIN A UTILITY LOCATION FOR ALLUNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. THE LOCATIONOF KNOWN UTILITIES IS SHOWN ON THE PLAN TO THE EXTENTPOSSIBLE. ALL DISCREPANCIES SHALL BE NOTED AND DISCUSSEDWITH THE ENGINEER PRIOR TO CONSTRUCTION.5. THE CONTRACTOR SHALL NOTIFY FRANKLIN COUNTY PUBLIC UTILITIESPRIOR TO TAPPING ANY MAIN, TURNING ANY EXISTING VALVES, ORBEGINNING CONSTRUCTION ON ANY SEGMENT OF THE PROJECT. ACURRENT COPY OF THE APPROVED DESIGN PLANS, ENCROACHMENTAGREEMENTS, AND SPECIFICATIONS OF THE UTILITY SHALL BEMAINTAINED ON SITE AT ALL TIMES.6. MAIN LOCATIONS, VALVE LOCATIONS, HYDRANT LOCATIONS, ANDSERVICE LOCATIONS ARE SHOWN FOR ILLUSTRATIVE PURPOSES.REFER TO STANDARD DETAILS FOR PRECISE LOCATION OF THESEITEMS. HYDRANTS SHALL BE LOCATED WITHIN 10' UTILITY EASEMENT.VALVES LOCATED WITHIN NCDOT RIGHT OF WAY SHALL BE INSTALLEDIN ACCORDANCE WITH NCDOT STANDARDS. VALVE MARKERS ANDVENTS SHOULD BE INSTALLED AT THE RIGHT OF WAY LINE. VALVESSHALL NOT BE LOCATED WITHIN PAVEMENT TO THE EXTENTPRACTICAL OR WITHIN THE LIMITS OF THE FRONT SLOPE OR BOTTOMOF THE DITCH.7. MINIMUM DEPTH OF BURY FOR WATER MAINS SHALL BE 4'.8. WATER SERVICE STUB-OUTS SHALL BE MADE PRIOR TO PLACEMENTOF ROADWAY STONE.9. TRACER WIRE SHALL NOT BE INSTALLED INSIDE GATE VALVE BOXES.CONTRACTOR SHALL INSTALL WIRES IN A 4” PVC PIPE CLEANOUT ATMAIN VALVES WITH A BRASS CAP AND CONCRETE DONUT.SANITARY SEWER CONSTRUCTION NOTES1. ALL SANITARY SEWER CONSTRUCTION TO BE IN ACCORDANCE WITHFRANKLIN COUNTY PUBLIC UTILITIES STANDARDS ANDSPECIFICATIONS FOR WATER AND SEWER.2. CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLINCOUNTY PUBLIC UTILITIES.3. MINIMUM DEPTH OF COVER FOR GRAVITY SEWERS SHALL BE 4'.4. GRAVITY SEWER WITHIN 50' OF SURFACE WATERS OR WETLANDS SHALLBE DUCTILE IRON PIPE AND HAVE MATERIALS, TESTING METHODS ANDACCEPTABILITY STANDARDS MEETING WATER MAIN STANDARDS (15ANCAC 18C).5. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND SANITARYSEWER SHALL BE 10 FEET. WHEN RUNNING PARALLEL, THE TOP OFSANITARY PIPING SHALL BE AT LEAST 18 INCHES BELOW THE BOTTOM OFTHE WATER MAIN. WHEN CROSSING, THE TOP OF SANITARY PIPING SHALLBE AT LEAST 24 INCHES BELOW THE BOTTOM OF THE WATER MAIN.6. MINIMUM SEPARATION BETWEEN SANITARY SEWER AND STORM DRAINAGEIS 24 INCHES.7. MINIMUM SEPARATION BETWEEN WATER AND STORM DRAINAGE IS 18INCHES.8. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWERFACILITIES WITH 18'' MINIMUM VERTICAL SEPARATION.9. MAXIMUM MANHOLE SPACING SHALL BE 400’.10. GRAVITY SEWER MANHOLES TO HAVE WATERTIGHT MANHOLE RING ANDCOVERS.PROP. 8" CL350 DUCTILEIRON WATER LINEPROP. HYDRANTASS'Y(1) PROP. 16" x 8" MJ TAPPING SLEEVE(1) PROP. 8" MJ TAPPING GATE VALVE AND BOXPIPE TO BE 8" CL350 DUCTILE IRON WATERLINEPROP. CLEANOUT FOR 4"SEWER SERVICE (TYP.)PROP. 5/8" WATERSERVICE METER (TYP.)PROP. STORM DRAINAGEINLET GRATE (TYP.)PROP. GRAVITY SEWER MANHOLE (TYP.)PROP. 8" 22.5° MJ BEND(1) PROP. 8" RJ 90° BEND (ANGLED UPWARDS AT 45°)(1) PROP. 8" RJ 90° BEND50 LF OF 16" STEEL CASING PIPE TO EXTENDMIN. 5' BEYOND EX. EDGE OF PAVEMENT(CROSS UNDER EXISTING 16" MAIN)CROSSING UNDERROAD VIA BORE & JACK.EX. SANITARY SEWER LINE (TYP.)(SIZE AND MATERIAL UNKNOWN)PROP. 20'FRANKLIN COUNTYSANITARY SEWEREASEMENTEX. STREAM(TYP.)BACKSIDE TAP SHOWN, BUT ISSUBJECT TO CHANGE BASED ONFIELD CONDITIONS AND LOCATION OFEXISTING WATERLINE.EX. SANITARY SEWERMANHOLETOP = 370.83'INV. IN = 362.52'INV. OUT = 362.23'PROP. VARIABLE WIDTHPUBLIC ACCESS ANDUTILITY EASEMENTPROP. 5/8" WATERSERVICE METER (TYP.)PROP. CLEANOUT FOR 4"SEWER SERVICE (TYP.)TYPICAL WATER ANDSEWER SERVICE LAYOUTPROP. 8" SDR35 GRAVITY SEWER(SEE SHEET C-10 FOR PLAN AND PROFILES)5NOTES1. ALL TOWNHOMES WITHIN 500' RADIUS OF EITHER EXISTING ORPROPOSED FIRE HYDRANTS.2. ALL WATER AND SEWER UTILITIES LOCATED WITHIN PUBLICEASEMENTS TO BE MAINTAINED BY FRANKLIN COUNTY PUBLICUTILITIES.3PROP. 8" x 6" MJ REDUCER55555PROP. VARIABLE WIDTHPUBLIC ACCESS ANDUTILITY EASEMENT TOBE 3' FROM PARCEL LINE
414239384037353634111210132928273031323323202419222125265261437981716141518GRADING AND DRAINAGE PLANC-660404020SCALE: 1 INCH = 40 FEETNNOTES1. SEE SHEET C-3 FOR STORMWATER DRAINAGE CALCULATIONS.2. PROPOSED CONTOURS SHOWN REPRESENT FINISH GRADES.3. PROPOSED ADA STALLS AND AISLES SHALL HAVE SLOPES NOSTEEPER THAN 1:48 (2%) IN ALL DIRECTIONS.4. CUT AND FILL SLOPE SHALL BE 3H:1V UNLESS OTHERWISE NOTED.5. RETAINING WALLS SHOWN ARE BY OTHERS.6. STORMWATER CONTROL MEASURES SHALL BE PRIVATE ANDMAINTAINED BY THE HOME OWNERS ASSOCIATION.NC HWY 56 (E GREEN ST)60' PUBLIC RIGHT-OF-WAYOAK RIDGE ROAD
60' PUBLIC RIGHT-O
F
-
W
A
Y PERKINSON WAY40' PUBLICRIGHT-OF-WAYTOWN OF FRANKLINTON20' SANITARY SEWEREASEMENTEX. STREAM(TYP.)50' TAR/PAMLICORIVER BUFFER FROMTOP OF BANK (TYP.)EX. VARIABLE WIDTHGREENWAY/UTILITYEASEMENT50' SID
E
Y
A
R
D
S
E
T
B
A
C
K
50' SID
E
Y
A
R
D
S
E
T
B
A
C
K50' REAR YARD SETBACK25' FRONT YARD SETBACKPROP. 24" CURB& GUTTER(TYP.)EX. SANITARY SEWER LINE (TYP.)(SIZE AND MATERIAL UNKNOWN)EX. SANITARYSEWER MANHOLE(TYP.)APPROX. LOCATIONEX. 16" WATER LINE(DEPTH UNKNOWN)PROP. VARIABLE WIDTHPUBLIC ACCESS ANDUTILITY EASEMENTEX. PROPERTY LINELEGENDEX. RIGHT-OF-WAYEX. EASEMENTEX. ADJACENT OWNERSEX. ROAD CENTERLINEEX. CHANNEL/STREAMEX. CHANNEL/STREAM BUFFEREX. CHAIN LINK FENCEEX. OVERHEAD ELECTRIC LINEEX. WATER LINEEX. SANITARY SEWEREX. STORM SEWERPROP. EASEMENTPROP. SETBACK LINEPROP. LOT LINESEX. FENCE AND EDGE OFASPHALT PAVEMENTEX. DRIVEWAY TOBE CLOSEDEX. TREE LINEEX. CONCRETE PADN/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 57PIN# 1865-66-3841N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396PIN# 1865-66-2587N/FJOHN WILLIAM POPEFOUNDATIOND.B. 2016, PG. 396P.B. 7, PG. 58-59PIN# 1865-66-2472N/FANDREW W. &KAITLYN A. TROTTERD.B. 1975, PG. 943P.B. 7, PG. 58-59PIN# 1865-66-2297N/FFRANKLIN COUNTYD.B. 1198, PG. 217P.B. 2010, PG. 172PIN# 1865-52-9270ABANDONED EX. SANITARYSEWER MANHOLE (TYP.)CB-2CB-1CB-4CB-3CB-6CB-5CB-8CB-9FES-2PROP. WATER LINEPROP. SANITARY SEWER324PROP. MAJOR CONTOUR (5')PROP. MINOR CONTOUR (1')325PROP. CURB INLETPROP. FLARED END SECTIONPROP. LIMIT OF DISTURBANCEPROP. STORM SEWERPROP. STORMWATERCONTROL MEASUREFES-1BEGIN PROP.PERMANENT SWALE #1ABEGIN PROP.PERMANENT SWALE #2APROP. 5' SIDEWALKFLUSH TOP OFCURBPROP. MAIL KIOSKPAD PER KIOSKINSTALLERINSET BSCALE: 1" = 20'SIDEWALK SHALL BEFLUSH AT TRANSITIONTO PAVEMENT WITH (1)2'X4' TRUNCATEDDOME PANEL AT EACHTRANSITIONSEE INSET B,THIS SHEETDI-7BEGIN PROP.PERMANENT SWALE #2BBEGIN PROP.PERMANENT SWALE #2CBEGIN PROP.PERMANENT SWALE #2DBEGIN PROP.PERMANENT SWALE #2EBEGIN PROP.PERMANENT SWALE #2FBEGIN PROP.PERMANENT SWALE #2GBEGIN PROP.PERMANENT SWALE #1BBEGIN PROP.PERMANENT SWALE #1CBEGIN PROP.PERMANENT SWALE #1DFFE SUMMARYLOT NO.FFE ELEV.1399.002398.003397.004396.005396.006395.007393.008392.009391.0010390.0011390.0012389.0013387.0014386.0015385.0016384.0017384.0018383.0019399.0020398.0021398.0022397.0023397.0024396.0025394.0026393.0027392.0028391.0029391.0030390.0031388.0032387.0033386.0034385.0035385.0036384.0037382.0038381.0039380.0040379.0041379.0042378.00PROP. 20'FRANKLIN COUNTYSANITARY SEWEREASEMENTPROP. VARIABLE WIDTH PUBLICACCESS AND UTILITY EASEMENT5
6+007+007+48414240PROP. PARCEL BOUNDARYPROP. RIGHT-OF-WAYPROP. LOT LINESSTORMWATER MANAGEMENTDETAILSC-99CALL 48 HOURS BEFOREYOU DIGNORTH CAROLINAONE-CALL CENTER1-800-632-49490202010SCALE: 1 INCH = 20 FEETNEX. FEMA FLOODPLAIN BOUNDARYEX. OVERHEAD ELECTRIC LINEEX. ADJACENT OWNERSEX. STREAMEX. FENCELEGENDEX. RIGHT-OF-WAYEX. STREAM BUFFEREX. WETLANDSEX. MAJOR CONTOUR (10')EX. MINOR CONTOUR (2')325PROP. EASEMENT324PROP. MAJOR CONTOUR (5')PROP. MINOR CONTOUR (1')325PROP. ROAD CENTERLINEPROP. DRAINAGE SWALEPROP. SANITARY SEWERPROP. STORM SEWERPROP. WATER LINEPROP. LIMIT OF DISTURBANCESHALLOW LAND AREADEEP POOL AREASHALLOW WATER AREASTORMWATER WETLAND CROSS-SECTIONNOT TO SCALEPPE ELEV 365'PROP. 1.5" SCHED 40 PVC W/90° TURNDOWNINV 365.00'2' FOREBAY2' DEEP POOL3" TO 6" SHALLOW WATERPROP. VARIABLE WIDTH PRIVATEACCESS & MAINTENANCEEASEMENTPROP. 30 LF WEIR AT ELEV. 367.00'LINED WITH NAG P300(OR APPROVED EQUAL)PROP. INV. OUT 363.00'3H:1V (TYP.)STORMWATER WETLAND PLAN VIEWSCALE: 1" = 20'PROP. 5' X 5' OUTLETSTRUCTUREPROP. 30 LF 15" RCPOUTLET PIPE @ 1.67%PROP. 10' WIDEDOUBLE SWING GATEPROP. 5' X 5' PRECASTCONCRETE RISER STRUCTURE4' X 4' GRATE ELEV. = 366.25'1 - 1.5'' ORIFICE ELEV. = 365.00'15" INV OUT = 363.50'30 LF 15'' RCP @ 1.67%TOP OF BANKELEV. = 368.00'PROP. EMERGENCY SPILLWAYELEV. = 367.00';LINED WITH NAG SC250(OR APPROVED EQUAL) FES INV = 363.00'ANTI-SEEP COLLAR3:
1
(
T
Y
P
.
)10'3:1 (TYP.)PROP. RIPRAP ENERGY DISSIPATORCLASS B RIP RAP 22" THICKLENGTH: 7.5'; WIDTH: 3.75'4'INSIDEPROP. TRASH RACK4' X 4' X 1'CONCRETE SUMP6'' #57 STONE BEDDINGINV OUT = 363.50'1112'(MIN)KEY TRENCH1STORMWATER WETLAND MAINTENANCE NOTES1. THE LANDSCAPE PROFESSIONAL MANAGING THE WETLAND MUSTUNDERSTAND THE BIOLOGICAL REQUIREMENTS OF THE PLANTS ANDMANAGE WATER LEVELS APPROPRIATELY TO PROVIDE FOR THEIR NEEDS.2. ALTHOUGH WETLAND PLANTS REQUIRE WATER FOR GROWTH ANDREPRODUCTION, THEY CAN BE KILLED BY DROWNING IN EXCESSIVELYDEEP WATER. USUALLY, INITIAL GROWTH IS BEST WITH TRANSPLANTEDPLANTS IN WET, WELL-AERATED SOIL. OCCASIONAL INUNDATIONFOLLOWED BY EXPOSURE TO AIR OF THE MAJORITY OF THE VEGETATIONENABLES THE PLANTS TO OBTAIN OXYGEN AND GROW OPTIMALLY.CONVERSELY, FREQUENT SOIL SATURATION IS IMPORTANT FOR WETLANDPLANT SURVIVAL.3. DRAMATIC SHIFTS CAN OCCUR AS PLANT SUCCESSION PROCEEDS. THEPLANT COMMUNITY REFLECTS MANAGEMENT AND CAN INDICATEPROBLEMS OR THE RESULTS OF IMPROVEMENTS. FOR EXAMPLE, AREQUIREMENT OF SUBMERGED AQUATIC PLANTS, SUCH AS PONDWEED(POTAMOGETON SPP.), IS LIGHT PENETRATION INTO THE WATER COLUMN.THE DISAPPEARANCE OF THESE PLANTS MAY INDICATE INADEQUATEWATER CLARITY. THE APPEARANCE OF INVASIVE SPECIES ORDEVELOPMENT OF A MONOCULTURE IS ALSO A SIGN OF A PROBLEM WITHTHE AQUATIC/SOIL/VEGETATIVE REQUIREMENTS. FOR INSTANCE, MANYINVASIVE SPECIES CAN QUICKLY SPREAD AND TAKE OVER A WETLAND. IFCATTAILS BECOME INVASIVE, THEY CAN BE REMOVED BY A LICENSEDAQUATIC PESTICIDE APPLICATOR BY WIPING AQUATIC GLYPHOSATE, ASYSTEMIC HERBICIDE, ON THE CATTAILS.4. UNLIKE MAINTENANCE REQUIREMENTS FOR WET OR DRY STORMWATERPONDS, SEDIMENT SHOULD ONLY BE SELECTIVELY REMOVED FROMSTORMWATER WETLANDS, PRIMARILY FROM THE FOREBAY.SEDIMENTREMOVAL DISTURBS STABLE VEGETATION COVER AND DISRUPTSFLOWPATHS THROUGH THE WETLAND. THE TOP FEW INCHES OFSEDIMENT SHOULD BE STOCKPILED SO THAT IT CAN BE REPLACED OVERTHE SURFACE OF THE WETLAND AFTER THE COMPLETION OF SEDIMENTREMOVAL TO RE-ESTABLISH THE VEGETATIVE COVER USING ITS OWNSEED BANK. ACCUMULATED SEDIMENT SHOULD BE REMOVED FROMAROUND INLET AND OUTLET STRUCTURES. NOTES1. THE WETLAND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION. CONSTRUCTION SHALLBE SEQUENCED SO THAT VEGETATION CAN BE PLANTED AND THE WETLAND BROUGHT ONLINEWITHIN 14 DAYS. PLANTS MAY NEED TO BE WATERED DURING THIS TIME IF THE DEVICE IS NOTBROUGHT ONLINE THE SAME DAY. STABILIZATION MAY BE IN THE FORM OF FINAL VEGETATIONPLANTINGS OR A TEMPORARY MEANS UNTIL THE VEGETATION BECOMES ESTABLISHED. IF USINGA TEMPORARY MEANS, CONTRACTOR SHALL PROVIDE A WET HYDROSEED MIX. CONTRACTORSHALL SCARIFY THE SOIL TO A HALF-INCH PRIOR TO HYDROSEEDING.2. INLET AND OUTLET CHANNELS SHALL BE PROTECTED FROM SCOUR THAT MAY OCCUR DURINGPERIODS OF HIGH FLOW. STANDARD EROSION CONTROL MEASURES SHOULD BE USED.3. THE STORMWATER WETLAND SHOULD BE STAKED AT THE ONSET OF THE PLANTING SEASON.WATER DEPTHS IN THE WETLAND SHOULD BE MEASURED TO CONFIRM THE ORIGINAL PLANTINGZONES. AT THIS TIME, IT MAY BE NECESSARY TO MODIFY THE PLANTING PLAN TO REFLECTALTERED DEPTHS OR THE AVAILABILITY OF WETLAND PLANT STOCK. CONTRACTOR SHALLCOORDINATE PLANTINGS, PLANTING ZONES AND WATER DEPTHS WITH THE ENGINEER.SURVEYED PLANTING ZONES SHOULD BE MARKED ON AN “AS-BUILT” OR RECORD DESIGN PLANAND LOCATED IN THE FIELD USING STAKES OR FLAGS.4. THE WETLAND DRAIN SHOULD BE FULLY OPENED FOR NO MORE THAN 3 DAYS PRIOR TO THEPLANTING DATE (WHICH SHOULD COINCIDE WITH THE DELIVERY DATE FOR THE WETLAND PLANTSTOCK) TO PRESERVE SOIL MOISTURE AND WORKABILITY.5. NURSERY STOCK SHALL BE TRANSPLANTED FROM LOCAL AQUATIC PLANT NURSERIES. THEOPTIMAL PERIOD FOR TRANSPLANTING EXTENDS FROM EARLY APRIL TO MID-JUNE SO THAT THEWETLAND PLANTS WILL HAVE A FULL GROWING SEASON TO BUILD THE ROOT RESERVES NEEDEDTO SURVIVE THE WINTER. HOWEVER, SOME SPECIES MAY BE PLANTED SUCCESSFULLY IN EARLYFALL. CONTRACTOR SHALL CONTACT NURSERY WELL IN ADVANCE OF CONSTRUCTION TOENSURE THAT THEY WILL HAVE THE DESIRED SPECIES AVAILABLE.6. POST-NURSERY CARE OF WETLAND PLANTS IS VERY IMPORTANT IN THE INTERVAL BETWEENDELIVERY OF THE PLANTS AND THEIR SUBSEQUENT INSTALLATION BECAUSE THEY ARE PRONETO DESICCATION. STOCK SHOULD BE FREQUENTLY WATERED AND SHADED.7. SHWT TO BE EVALUATED PRIOR TO CONSTRUCTION. IF SHWT IS WITHIN 6" OF PPE ELEVATION, ACLAY LINER WILL NOT BE REQUIRED. OTHERWISE, INSTALLATION OF A 6" CLAY LINER WILL BEREQUIRED. CLAY LINER SHALL HAVE A MINIMUM 15% PASSING THE #200 SIEVE AND A MAXPERMEABILITY OF 1 X 10-5 CM/SEC. ACCEPTABLE ALTERNATIVES INCLUDE A 30 MIL POLY-LINEROR A BENTONITE LINER.8. GRADES SHOWN REPRESENT FINISH GRADE ELEVATIONS. TO ACHIEVE FINISH GRADEELEVATIONS, INSTALL 4" OF TOPSOIL.9. PROVIDE PLANTS PER TABLE ON THIS SHEET. DAM STRUCTURE AND PERIMETER FILL SLOPESSHALL BE PLANTED WITH NON-CLUMPING TURF GRASS. TREES AND WOODY SHRUBS NOTALLOWED.10. CATTAILS SHALL NOT BE PLANTED IN WETLAND.OUTLET STRUCTURE NOTES & SPECIFICATIONS1. RCP OUTLET SHALL BE CLASS III RCP MEETING REQUIREMENTS OF ASTM C76. THE PIPE JOINTSSHALL BE MORTAR OR FLEXIBLE PLASTIC TYPE JOINT.2. THE MANHOLE OUTLET RISER SHALL MEET ASTM C-913. THE MANHOLE JOINTS SHALL BE ASTMC-443 RUBBER GASKET JOINTS. MANHOLE JOINTS SHALL BE SECURELY ANCHORED TO PREVENTSEPARATION. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE MANHOLE SECTIONANCHORING SYSTEM.3. WATERTIGHT SEAL SHALL BE PROVIDED AT RISER/BARREL INTERFACE. PERVIOUS MATERIALSUCH AS SAND, GRAVEL, OR CRUSHED STONE SHALL NOT BE USED AS BACKFILL AROUND THEPIPE OR ANTI-SEEP COLLAR. FILL MATERIAL AROUND THE RISER/BARREL STRUCTURE SHALL BEPLACED IN 4'' LAYERS AND COMPACTED TO THE SAME DENSITY AS THE ADJACENT EMBANKMENT.4. OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS 1'-2'' ON CENTER. STEPS SHALL BE INACCORDANCE WITH NCDOT STD. 840.66.5. CONCRETE ANTI-FLOATATION BLOCK SHALL BE PRECAST DURING FABRICATION. IF THECONCRETE ANTI-FLOATATION BLOCK IS CAST SEPARATE FROM THE MANHOLE ASSEMBLY THECONTRACTOR SHALL BE RESPONSIBLE FOR ANCHORING THE ANTI-FLOATATION BLOCK TO THEMANHOLE RISER ASSEMBLY.6. ALL POURED CONCRETE SHALL BE A MINIMUM 3,000 PSI (28 DAY) UNLESS OTHERWISE NOTED.7. NON-WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AROUND EACH JOINT OF THE RCP OUTLETBARREL IN 2' WIDE STRIPS CENTERED ON JOINT. FABRIC SHALL BE AMOCO STYLE 4553POLYPROPYLENE NON-WOVEN NEEDLE PUNCHED OR APPROVED EQUAL (NON-WOVEN FABRIC).BERM SPECIFICATIONS1. ALL FILL SOILS FOR BERM SECTION SHALL BE CLEAN, IMPERMEABLE MATERIAL AND COMPACTEDTO AT LEAST 98% STANDARD PROCTOR MAXIMUM DRY DENSITY, AT OPTIMUM MOISTURECONTENT. NO BLASTED MATERIALS SHALL BE USED IN THE EMBANKMENT CONSTRUCTION. SOILSSHALL NOT EXHIBIT SIGNIFICANT SHRINK/SWELL OR DISPERSIVE CHARACTERISTICS. THE ON-SITEGEOTECHNICAL ENGINEER SHALL APPROVE THE SOILS FOR PLACEMENT WITHIN THE BERMSECTION. THE GEOTECHNICAL ENGINEER SHALL ALSO SPECIFY THE METHODS TO BE USED FORPLACEMENT OF FILL.2. IN ALL FILL AREAS OF THE BERM, A SOILS COMPACTION TEST SHALL BE CONDUCTED EACH 2,500SQUARE FEET PER VERTICAL CUT OF FILL.3. A KEY TRENCH IS TO BE PROVIDED IN ALL FILL AREAS. TRENCH TO EXTEND A MINIMUM OF TWOFEET BELOW EXISTING GRADE. THE MINIMUM BOTTOM WIDTH SHALL BE WIDE ENOUGH TOPERMIT OPERATION OF EXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE SHALL BELESS THAN 2' WIDE. CONTRACTOR SHALL CONFIRM KEY TRENCH DEPTH AND WIDTH WITH THEON-SITE GEOTECHNICAL ENGINEER. SOILS AND COMPACTION FOR KEY TRENCH SHALL MEET ALLREQUIREMENTS OF #1 ABOVE.4. FILL PLACEMENT SHALL NOT EXCEED A MAXIMUM OF 8'' LIFTS. EACH LIFT SHALL BE CONTINUOUSFOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERMSECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLYPREPARED FOR FILL PLACEMENT.5. NO TREES OF ANY TYPE MAY BE LOCATED ON THE BERM SECTION.6. WEIR SHALL BE LINED WITH NORTH AMERICAN GREEN SC250 MATTING, OR APPROVED EQUAL.7. SIDE SLOPES SHALL BE LINED WITH NAG S75, OR APPROVED EQUAL.8. INSTALL ANTI-SEEP COLLAR AT MIDPOINT OF OUTLET PIPE. CONCRETE SHALL BE 3,000 PSI (28DAYS) AND REINFORCED WITH #4 REBAR 12'' O.C. EACH WAY. MINIMUM BEARING CAPACITYBENEATH COLLAR SHALL BE 2,000 PSF.PROP. 4' TALL BLACKALUMINUM FENCE TOSURROUND SCMPROP. RETAINING WALL(DESIGN BY OTHERS)365.00' X365.00' X365.00' X365.00' X364.25' X364.50' X364.50' X364.50' X364.50' X364.25' X364.50' XSTAGE-STORAGE TABLEELEVATION(FT)SURFACE AREA(SF)TOTAL STORAGE(CF)365.005,3550366.006,2555,799367.007,21512,528368.008,23120,246STORMWATER WETLAND PLANTING TABLEQUANTITYBOTANICAL NAMECOMMON NAMESIZE SPACINGSHALLOW WATER PLANTINGS (AREA = 2,568 SQ. FT.; 50 HERBACEOUS PLANTS PER 200 SQ. FT.; 642 TOTAL PLANTS REQ.)128 ACORUS SUBCORDATUMSWEETFLAG4 CU. IN.2' O.C.128HYDROLEA QUADRIVALVISWATERPOD4 CU. IN.2' O.C.128 IRIS VIRGINICABLUE FLAG IRIS4 CU. IN.2' O.C.129 SAGITTARIA LATIFOLIADUCK POTATO4 CU. IN.2' O.C.129 SAURURUS CERNUUSLIZARD'S TAIL4 CU. IN.2' O.C.SHALLOW LAND PLANTINGS (AREA = 1,924 SQ. FT.; 50 HERBACEOUS PLANTS PER 200 SQ. FT.; 481 TOTAL PLANTS REQ.)160 CAREX TENERAQUILL SEDGE4 CU. IN.2' O.C.160 HIBISCUS COCCINEUSSCARLET ROSE MALLOW4 CU. IN.2' O.C.161 LOBELIA ELONGATALONGLEAF LOBELIA4 CU. IN.2' O.C.DEEP POOL30 ELEOCHARIS ACICULARISNEEDLE SPIKERUSHBARE ROOTN/A30 NUPHAR LUTEA SSP. ADVENAYELLOW POND-LILYBARE ROOTN/ATW 369.00'BW 369.00'TW 375.00'BW 369.00'TW 376.00'BW 369.00'TW 376.00'BW 369.00'TW 369.00'BW 369.00'PROP. 20' FRANKLINCOUNTY SANITARYSEWER EASEMENT55PROP. FOREBAYPROP. FOREBAY55
ROAD WIDENING DETAILSC-12120404020SCALE: 1 INCH = 40 FEETPAVEMENT WIDTH VARIES;SEE NOTES 1 & 2 BELOWVARIESSEENOTES3 & 4VARIESEXISTING 60' RIGHT-OF-WAY3H:1V3H:1V1.5'' OVERLAY TOMATCH EXISTINGCROSS SLOPEEXISTINGSLOPEVARIES4'' I19.0C INTERMEDIATECOURSE LEFT 1.5'' LOWERTHAN THE EXISTING PAVEMENT10" NCDOT TYPE CABC,AGGREGATE BASE COURSE.IF LESS THAN 6' IN WIDTHUSE 5'' B25.0CCOMPACTEDSUBGRADE3'' ((2) 1.5'' LIFTS) S9.5B SURFACE COURSE:a. MILL OUT 1.5'' 1.5' INTO THE ADJACENTPAVEMENT TO PLACE A 1.5'' LAYER OF S9.5B MIXFROM THE MILLED OUT EDGE TO THE NEW EDGEOF PAVEMENT.b. FINAL LAYER SHALL BE 1.5'' OF S9.5B TOOVERLAY THE ENTIRE PROJECT0.080.08NC HIGHWAY 56 (EAST GREEN STREET)WIDENING CROSS-SECTIONNO SCALE℄NOTES1. EXISTING PAVEMENT WIDTH = VARIES; APPROXIMATELY 32'.2.PROPOSED PAVEMENT WIDTH = 38'; 6' SYMMETRICALWIDENING PLUS 1' PAVED SHOULDER.3. SHOULDER SOUTH OF NC HWY 56 SHALL MATCH EXISTING.4. SHOULDER NORTH OF NC HWY 56 SHALL INCLUDE 30'' CURBAND GUTTER AND MATCH EXISTING5