HomeMy WebLinkAboutNC0021181_CBI_20180424Environmental Quality ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director April 24, 2018 Mr. Adrian Miller, City Manager City of Belmont P.O. Box 431 Belmont, NC 28012 Subject: Bioassay results Belmont WWTP NPDES Permit No. NCO021181 Gaston County Dear Mr. Miller: Enclosed is a copy of the Bioassay results taken during for the inspection conducted at the subject facility on February 15, 2018, by Maria Schutte and Ori Tuvia. The sampling results revealed that the facility passed the Whole Effluent Toxicity test (see attached results). Please inform the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. If you any questions, please contact On Tuvia at (704) 235-2190, or via email at ori.tuviagncderin gov. Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources Cc: NPDES, MRO Files (Laserfiche) Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org Division of Water Resources March 8, 2018 MEMORANDUM To: Corey Basinger Water Quality Regional Operations, MRO Through: Cindy A. Moore Supervisor, Aquatic Toxicology Branch (ATB) From: Carol Hollenkamp Quality Assurance Officer, Aquatic Toxicology Branch (ATB) Subject: Whole effluent toxicity test results Belmont WWTP NPDES Permit # NCO021181/001 Gaston County The aquatic toxicity test using flow -proportional composite samples of effluent discharged from Belmont WWTP has been completed. Belmont WWTP has a permitted effluent discharge of 5.0 million gallons per day (MGD) entering the Catawba River (7Q10 of 95.0 CFS). Whole effluent samples were collected on February 13 and February 15 by Ori Tuvia and facility representative Tanya Setzer for use in a chronic Ceriodaphnia dubia pass -fail toxicity test. The test passed. Toxicity test information follows. Test Type 3 -Brood Ceriodaphnia dubia chronic pass -fail Test Result Pass Test Concentrations 8% Control Survival 92% Control Mean Reproduction 24 neonates Test Treatment Survival 100% Treatment Mean Reproduction First Sample pH First Sample Conductivity First Sample Total Residual Chlorine Second Sample pH Second Sample Conductivity Second Sample Total Residual Chlorine 32.5 neonates 7.01 SU 673 micromhos/cm <0.1 mg/L 7.26 SU 1144 micromhos/cm <0.1 mg/L Test results for the above samples indicate that the effluent would not be predicted to have water quality impacts. These samples were split and tested by ETT. The chronic Ceriodaphnia dubia pass/fail test run by ETT resulted in a pass. Please contact us if you have any questions or if further effluent toxicity monitoring is desired. We may be reached at (919) 743-8401. Basin: Catawba cc: Ori Tuvia (MRO)