Loading...
HomeMy WebLinkAboutWQ0032740_Change of Ownership Approval_20180410 ROY COOPER Governor MICHAEL S. REGAN Secretary Water Resources LINDA CULPEPPER ENVIRONMENTAL QUALITY Interim Director April 10, 2018 Ms Ann Hardy County Manager Brunswick County PO Box 249 Bolivia, North Carolina 28422 Subject: Change of Ownership Approval Permit No.WQ0032740 Harbor Walk Subdivision Brunswick County Dear Ms Hardy Division personnel have reviewed and approved your permit modification request for Permit No WQ0032740. This modification is to change ownership from St James Plantation, LLC to Brunswick County, and Brunswick County is now responsible for the continued operation and maintenance of the subject wastewater collection extension. Our database has been revised to reflect the ownership change. The Permittee shall maintain compliance with its individual system-wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400 and G.S 143-215.9B. If an individual permit is not required,the performance criteria as required by 15A NCAC 02T.0403 shall be met. If you have any other questions regarding this matter please contact Christyn Fertenbaugh, at (919) 807-6312 [email. christyn.fertenbaugh@ncdenr.gov] Sincerely, for Linda Culpepper, Interim Director Division of Water Resources, NCDEQ cc Mr. Robert Masters,St.James Plantation, LLC(bobby masters@stiamesplantation corn) Wilmington Regional Office,Water Quality Regional Operations Section(chad coburn 'ncdenr.gov) Central Files—WQ0032740 PERCS Files(electronic copy) ,,�W'•Not) ing Compares:',, State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh,North Carolina 27699-1617 Michael F Easley,Governor QG William G Ross Jr,Secretary North Carolina Department of Environment and Natural Resources Coleen H Sullins,Director p Division of Water Quality ,.:+rt " May 9,2008MAY I 6 71,08 Mr. Bill Schoettelkotte St. James Plantation, LLC. --- ------- PO Box 10879 Southport,North Carolina 28461 Subject: Permit No. WQ0032740 Express Permit Low Pressure Sewer System Harbor Walk Subdivision Brunswick County Dear Mr. Schoettelkotte: In accordance with your Express Permit application received February 12, 2008, and additional information received by the Division, we are forwarding herewith Permit No. WQ0032740 dated May 9, 2008,to St. James Plantation, LLC for the construction and operation of the subject wastewater collection system. This Permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh,NC 27699-6714. Unless such demands are made this permit shall be final and binding. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the approved plans and specifications. Mail the Certification to the Construction Grants &Loans Section, 1633 Mail Service Center,Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) One set of approved plans and specifications is being forwarded to you. None rthCarolina Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh,NC 27699-1617 Phone(919)733-7015 Customer Service Internet www ncwaterquality ora 512 N Salisbury St Raleigh,NC 27604 FAX (919)733-2496 1-877-623-6748 An Equal Opportunely/Affirmative Action Employer—50%Recycled/10%Post Consumer Paper a a Mr. Bill Schoettelkotte May 9, 2008 Page 2 If you need additional information concerning this matter,please contact Adrian Eaton at(919) 715-3283 or Ken Pohlig, Ph.D.,P.E.,Acting Supervisor at(919) 715-6221. Sincerely, 0a--,/,--4:€-P/Hr. /54(- -)Q-tee t&Coleen H. Sullins ae/kp cc: Brunswick County Health Department Ken Pohlig,Ph.D., P.E., Acting Supervisor Daniel M. Blaisdell P.E. Adrian Eaton Wilmington=Regional Office,Water=Quality Section(Permit WQ0023693)2 John Klein, P.E., Stewart Engineering, fnc.-201 North friar Street, Suite 103, Wilmington, NC 28401 Permit Application File WQ0032740 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT MAY I 6 2008 ti . r --- r 143, General In accordance with the provisions of h rta le 21 of applicable Rules and RegulationsStatutes f North Carolina as amended, and of pp1 cable PERMISSION IS HEREBY GRANTED TO ST. JAMES PLANTATION, LLC Brunswick County FOR THE construction and operation of a pressure sewer collection system consisting of approximately 320 linear feet of 1.5-inch pressure sewer pipe, approximately 570 linear feet of 2-inch pressure sewer pipe, approximately 70 linear feet of 2.5-inch pressure sewer pipe, 11 duplex pump stations, on-site audible and visual high water alarms,back up portable generator,telemetry to serve 11 buildings (84 units at 210 GPD/unit, see attachment A) and one pool amenity(840 -GPD, see attachment A) as a part of Harbor Walk Condominiums Subdivision, and the discharge of 0 GPD (this project's flow of 18,480 GPD is in the Brunswick County owned collection system permit WQ0018300 dated May 9,2008) of collected wastewater into the Brunswick County Sea Trail WWTF (WQ0023693)pursuant to the application received on February 12, 2008, and subsequent additional information received by the Division, and in conformity with the project plans, specifications, and other supporting and considered a part of this permata subsequently filed and d by the Department of Environment and Natural Resources it. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit,the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system-wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400. If an individual permit is not required,the following performance criteria shall be met as provided in 15A NCAC 2T .0400: Mr. Bill Schoettelkotte May 9, 2008 Permit No. WQ0032740 Page 2 (a) The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. (b) A map of the sewer system shall be developed and actively maintained. (c) An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response shall be developed and implemented. (d) Pump stations that are not connected to a telemetry system(i.e.,remote alarm system) shall be inspected by the permittee or its representative every day(i.e., 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. (e) High-priority sewers shall be inspected by the permittee or its representative at least once every six-months and inspections are documented. (f) A general observation by the permittee or its representative of the entire sewer system shall be conducted at least once per year. (g) Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 02B .0506(a), and public notice shall be provided as required by G.S. 143-215.1C. (h) A Grease Control Program shall be established as follows: (i) For publicly owned collection systems,the Grease Control Program shall include at least bi-annual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors for new construction and retrofit, if necessary, of grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. (ii) For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. (iii) Grease education materials shall be distributed more often than required in Parts (i) and(ii) of this Subparagraph if necessary to prevent grease-related sanitary sewer overflows. (1) Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. (1) Documentation shall be kept for Subparagraphs (a)through(i) for a minimum of three years with exception of the map,which shall be maintained for the life of the system. 4. The sewage and wastewater collected by this system shall be treated in Brunswick County Sea Trail WWTF (WQ0023693) existing sewerage system prior to being land applied by spray irrigation. Mr. Bill Schoettelkotte May 9, 2008 Permit No. WQ0032740 Page 3 5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Construction Grants & Loans Section, 1633 Mail Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The Permittee shall provide for the pump station and force main the following items: (a) Pump Station Reliability: (i) Pump stations, except when exempted by Subparagraph(j)(2) of 15A NCAC 02T.0305, shall be designed with multiple pumps such that peak flow can be pumped with the largest pump out of service. (ii) A standby power source or pump is required at all pump stations except for those pump stations subject to Subparagraph(j)(2) of 15A NCAC 02T.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. (iii) As an alternative to Part(ii) for pump stations with an average daily design flow less than 15,000 gallons per day as calculated using 15A NCAC 02T.0114, t Mr. Bill Schoettelkotte May 9, 2008 Permit No. WQ0032740 Page 4 a portable power source or pumping capability may be utilized. It shall be demonstrated to the Division that the portable source is owned or contracted by the permittee and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (iv) As an alternative to Part(ii) for pump or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24-hours worth of wastewater storage or, exceed the greatest power outage over the last three years or the documented response time to replace a failed pump, whichever is greater. Documentation shall be required pursuant to the permit application. (v) All pump stations designed for two pumps or more shall have a telemetry system to provide remote notification of a problem condition to include power failure and high water alarm. (vi) High water audio and visual alarm. (b) Pump stations shall have a permanent weatherproof sign stating the pump station identifier, 24-hour emergency number and instructions to call in case of emergency. Simplex pump or vacuum stations serving a single-family residence shall have a placard or sticker placed inside the control panel with a 24-hour emergency contact number. (c) Screened vents for all wet wells. (d) The public shall be restricted access to the site and equipment. (e) Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. The facilities shall be constructed in accordance with the requirements of the North Carolina Sedimentation Pollution Control Act. 14. If applicable, the Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is made a condition of this Permit. Noncompliance with the terms of the Operational Agreement may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. A copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed shall be submitted with the engineer's certification prior to operation. 15. Any abandoning of the existing facilities must be done in accordance with the requirements of the Division of Water Quality's Wilmington Regional Office. Mr. Bill Schoettelkotte ' May 9, 2008 Permit No. WQ0032740 Page 5 16 Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Wilmington Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition I(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 17. The Permittee shall maintain on hand for immediate installation a supply of spare, fully operational pump units of each type used in the pressure sewer system. The number of pumps on hand shall not be less than 10 percent of the number of installed units or one unit, whichever is greater. 18. Each pump station shall be clearly and conspicuously posted with the telephone number of the owner/operator of the pressure sewer system and instructions to call the number in the event of high water alarm activation. 19.No flow shall be made tributary from the subject sewer system permitted herein until the receiving downstream sewer (WQ0018300 issued May 9, 2008) has been constructed and the engineer's certification has been received by the Division of Water Quality. Permit issued this the 9th Day of May 2008 ZONH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 4r. e /' te, Coleen H. Sullins,Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. WQ0032740 Appendix A Harbor Walk Condominiums Subdivision WQ0032740 Issues May 9, 2008 Total# Total ,-;,uilding Number Units GPD 1 2 3 4 5 6 7 8 9 10 11 Pool P. p Station 8 1 units 8 1680 8 2 units 8 1680 6 3 units 6 1260 4 840 4 + 4 units GPD 840GPD 1680 • 6 4 5 units units 10 2100 4 4 6 units units 8 1680 4 4 7 units units 8 1680 4 4 8 units units 8 1680 4 4 9 units units 8 1680 8 10 units 8 1680 8 11 units 8 1680 18480