Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQCSD0173_20180226_Compliance Evaluation Inspection
• ROY COOPER Gore;ret r201 MICHAEL S REGAN a ' R Sccrctar�, LINDA CULPEPPER Water Resources Lite,tin DI,ecto Envuonmental Quality February 26, 2018 Shannon V.Becker,President Aqua North Carolina,Inc 202 Mackenan Court Cary,NC 27511 Subject Compliance Evaluation Inspection Crooked Creek Collection System—WQCSD0173 Wake County Dear Mr Becker, Andy Neal of the Raleigh Regional Office conducted a compliance evaluation inspection on February 20, 2018 The assistance of Mr. Bobby Ball,Utility Tech III, was appreciated Please find the attached Basin-wide Information Management System(BIMS)inspection checklist summarizing the inspection. Findmgs during the inspection were as follows WQCSD0173 Crooked Creek Collection System Compliance Inspection Evaluation 1. All wastewater flow is conveyed to and treated at the Crooked Creek wastewater treatment plant (NC0062715) 2 The Crooked Creek collection system has 2 pump stations Sawyer's Mill and Johnson Pond--both of which have secured access, operational audible / visible alarms, telemetry, and emergency contact information signs.Alarms operated when the high-water float was lifted, and telemetry was operational Both wet wells exhibited very little to no waste build-up. Pump stations are connected to on-site generators which are checked weekly and exercised monthly Per Mr Ball and corresponding logbooks, all pump stations are mspected weekly 3 Per Mr Ball,the Crooked Creek collection system has an unknown length of gravity sewer Per Mr.Ball's records, 735 feet of sewer line were cleaned in 2017 4 No map of the sewer system was available for review during the inspection 5 The Crooked Creek collection system uses the company's standard educational material for their Fats,Oils, and Grease Program.Material distribution method was unavailable during the inspection 6 Per Mr Ball,the Crooked Creek collection system has no high-priority lines 7 No Spill Response Action Plan was available for review during the inspection 8. No right-of-way maintenance records were available for review dunng the inspection -:5-7- '°'Nothing Compares" -. _ State of North Carolina I Environmental Quality I Water Resources I Raleigh Regional Office 1628 Mail service Center I Raleigh,North Carolina 27699-1628 - 919-791-4200-- — — — --- ., i" `G 41. ,...f t,..f rf `„{` 9, $ �.'� Crooked Creek Collection System—WQCSD0173 Compliance Evaluation Inspection—page 2 of 2 9 DWR records indicate that no sanitary sewer overflows (SSOs) liave been reported for the subject collection system since May of 2007 Please respond to above items 3, 4, 5, 7, and 8 in writing within 30 days of receipt of this letter. Specifically, please include in your written response a description of how a system map and all required records will be maintained hereafter. Thank you for your time and assistance with this inspection If you have any questions about this inspection or this letter, please contact Andy Neal at andvnedl i ILdLiir Loi or 919-791-4200 Si cereI' , Danny Smith/ Water Quality Regional Operations Raleigh Regional Office cc Central Files RRO File L - P F *-- ,�^�a�r�,- k f.;'� r T +-'' sty :a°'" «�< .� 9, .� ,�. �� �'� '�' T� � r'�"-'e`�w � � ms's ,� %,�..2 '>, .-�._a��w.»•.i-Y�sA.Y_`�^:'"�.."z�w� ..:`:` ��`. �e., ..,�' �g�°��.` 'JFc_�i: ":'nP�..�f �.. vr�,a��;: fo. . _ _ _ _.,.. s ,'ii'tl�i.'.. Compliance Inspection Report Permit WQCSD0173 Effective 03/01/00 Expiration Owner Aqua North Carolina Inc SOC Effective Expiration Facility Crooked Creek Collection System County Wake Region Raleigh Contact Person Shannon V Becker Title President Phone 919-653-5570 Directions to Facility System Classifications Primary ORC Certification Phone Secondary ORC(s) On-Site Representative(s) Related Permits NC0062715 Aqua North Carolina Inc-Crooked Creek WWTP Inspection Date 02/20/2018 Entry Time 01 OOPM Exit Time 02 OOPM Primary Inspector Andrew W Neal Phone 919-791-4248 Secondary Inspector(s) Reason for Inspection Routine Inspection Type Collection System Inspect Non Sampling Permit Inspection Type Deemed permitted collection system management and operation Facility Status ❑ Compliant ❑ Not Compliant Question Areas ® Miscellaneous Questions ® Performance Standards ; Operation&Maint Reqmts ® Records ® Inspections ® Pump Station (See attachment summary) Page 1 Permit WQCSD0173 Owner-Facility Aqua North Carolina Inc Inspection Date 02/20/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Inspection Summary WQCSD0173 Crooked Creek Collection System Compliance Inspection Evaluation 1 All wastewater flow is conveyed to and treated at the Crooked Creek wastewater treatment plant(NC0062715) -2- The Crooked-Creek collection system has 2 pump statiohs Sawyer's-Mill arid Johnson Pond--both-of which have- - secured access,operational audible/visible alarms,telemetry,and emergency contact information signs Alarms operated when the high-water float was lifted,and telemetry was operational Both wet wells exhibited very little to no waste build-up Pump stations are connected to on-site generators which are checked weekly and exercised monthly Per Mr Ball and corresponding logbooks,all pump stations are inspected weekly 3 Per Mr Ball,the Crooked Creek collection system has an unknown length of gravity sewer Per Mr Ball's records,735 feet of sewer line were cleaned in 2017 4 No map of the sewer system was available for review during the inspection 5 The Crooked Creek collection system uses the company's standard educational material for their Fats, Oils,and Grease Program Material distribution method was unavailable during the inspection 6 Per Mr Ball,the Crooked Creek collection system has no high-priority lines 7 No Spill Response Action Plan was available for review during the inspection 8 No right-of-way maintenance records were available for review during the inspection 9 DWR records indicate that no sanitary sewer overflows(SSOs)have been reported for the subject collection system since May of 2007 Please respond to above items 3,4,5,7, and 8 in writing within 30 days of receipt of this letter Specifically, please include in your written response a description of how a system map and all required records will be maintained hereafter Page 2 Permit WQCSD0173 Owner-Facility Aqua North Carolina Inc Inspection Date 02/20/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? U ❑ ❑ ❑ What educational tools are used? Is Sewer Use Ordinance/Legal Authority available? 000 • Does it appear that the Sewer Use Ordinance is enforced? 000 • Is Grease Trap Ordinance available? 000 • Is Septic Tank Ordinance available(as applicable,i e annexation) 000 • List enforcement actions by permittee,if any,in the last 12 months Has an acceptable Capital Improvement Plan(CIP)been implemented? 00 • 0 Does CIP address short term needs and long term 1"master plan\"concepts? 00110 Does CIP cover three to five year period? 00110 Does CIP include Goal Statement? 00 • 0 Does CIP include description of project area? 00110 Does CIP include description of existing facilities? 00110 Does CIP include known deficiencies? 00110 Does CIP include forecasted future needs? 00110 Is CIF designated only for wastewater collection and treatment? ❑ ❑ E ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? ® 000 If no,describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ® ❑ ❑ 0 #Does the sign include Instructions for notification? ® ❑ ❑ ❑ Pump station identifier? ® ❑ ❑ ❑ 24-hour contact numbers U ❑ ❑ ❑ If no,list deficient pump stations #Do ALL pump stations have an"auto polling"feature/SCADA? 11000 Number of pump stations 2 Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 2 Number of pump stations that have only audible and visual alarms 0 Number of pump stations that do not meet permit requirements 0 #Does the permittee have a root control program? 000IE Page 3 Permit WQCSD0173 Owner-Facility Aqua North Carolina Inc Inspection Date 02/20/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine #If yes,date implemented'? Describe Comment Inspections Yes No NA NE Are maintenance records for sewer lines available? U ❑ ❑ ❑ Are records available that document pump station inspections? • ❑ ❑ El Are SCADA or telemetry equipped pump stations inspected at least once a week'? I. El El El Are non-SCADA/telemetry equipped pump stations inspected every day'? ❑ ❑ • ❑ Are records available that document citizen complaints'? ❑ El El • #Do you have a system to conduct an annual observation o-entire system'? ■ El ❑ 0 #Has there been an observation of remote areas in the last /ear? • ❑ El El Are records available that document inspections of high-priority lines'? ❑ El ® El Has there been visual inspections of high-priority lines in last six months'? 1=10E0 Comment Operation&Maintenance Requirements Yes No NA NE Are all log books available'? El ❑ 0 II Does supervisor review all log books on a regular basis'? El El ❑ II Does the supervisor have plans to address documented short-term problem areas'? ❑ ❑ ❑ 111 What is the schedule for reviewing inspection,maintenance,&operations logs and problem areas'? Are maintenance records for equipment available'? ® El El El Is a schedule maintained for testing emergency/standby equipment'? ® 0 El El What is the schedule for testing emergency/standby equipment? weekly Do pump station logs include Inside and outside cleaning and debris removal'? ® ❑ El El Inspecting and exercising all valves'? ® El El ❑ Inspecting and lubricating pumps and other equipment'? ® ❑ ❑ El Inspecting alarms,telemetry and auxiliary equipment'? ® El p ❑ Is there at least one spare pump for each pump station w/o pump reliability'? El El ® ❑ Are maintenance records for right-of-ways available'? 0 0 0 Are right-of-ways currently accessible in the event of an emergency'? ® El ❑ ❑ Are system cleaning records available'? ® El El El Has at least 10%of system been cleaned annually'? El ❑ El 11 What areas are scheduled for cleaning in the next 12 months'? Mr Ball had line cleaning documentation for 2017,which amounted to 735'of line He was unsure of the total length of line to get an accurate percentage for annual cleaning, Is a Spill Response Action Plan available'? ❑ Q E, El El Does the plan include Page 4 Permit WQCSD0173 Owner-Facility Aqua North Carolina Inc Inspection Date 02/20/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine 24-hour contact numbers ❑ ❑ • ❑ Response time ❑ ❑ U 0 Equipment list and spare parts inventory ❑ 0 • 0 Access to cleaning equipment 0 0 U ❑ Access to construction crews,contractors,and/or engineers 0 0 • 0 Source of emergency funds 0 0 ■ ❑ Site sanitation and cleanup materials 0 0 III 0 Post-overflow/spill assessment 0 0 MI 0 Is a Spill Response Action Plan available for all personnel? 01100 Is the spare parts inventory adequate'? ❑ 0 0 i Comment No spill response plan was available for review during inspection Records Yes No NA NE Are adequate records of all SSOs,spills and complaints available'? 0 © 0 0 Are records of SSOs that are under the reportable threshold available'? 00011 Do spill records indicate repeated overflows(2 or more in 12 months)at same location'? ❑ ❑ ❑ • If yes,is there a corrective action plan'? 0 0 ❑ • Is a map of the system available'? 0 U 0 0 Does the map include Pipe sizes 0 MI 0 0 Pipe materials 0 ® 0 0 Pipe location ❑ ® ❑ ❑ Flow direction ❑ ® 0 0 Approximate pipe age ❑ ® 0 ❑ Number of service taps ❑ ® ❑ 0 Pump stations and capacity 0 IS ❑ 0 If no,what percent is complete'? List any modifications and extensions that need to be added to the map No map was available for review during inspection #Does the permittee have a copy of their permit'? ❑ ❑ ® 0 Comment No records other than pump station logs and amount of line cleaning were available for review during inspection SAWYER'S MILL - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available'? IN 0 ❑ ❑ Is it accessible in all weather conditions'? ® ❑ 0 0 #Is general housekeeping acceptable'? ili ❑ ❑ 0 Page 5 i ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ® ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ W ❑ O 000011 • 000001=1000001110000 ❑ ❑ ❑ ❑ ❑ ❑ z ❑ w • 00000000000000000000000 ❑ ❑ ❑ ❑ ❑ ❑ z ❑ 11 ® ❑ ■ ❑ ❑ 0 • ® ® ■ ® ❑ ❑ ® ® ❑ ® ® ® ® C E ® u' . T a } _N 5 O C 1 O N N a) 0) C CL E Ca co C O Z U O N ' a , — N ,p -E- o'(T) C E U L co o C O 0 Z U m a) 0O < U d 0. C' T 0 LL C `C O m m a, C a10 oN O C- C 0 0 C 0 Q .0 w O 0 a) 0. Y L m c- _8 0 N h N 0 L C c. Q L >i O @ c 'O O N U .L-- O 7 > a C O 2 0 O 0 C. O O- M 0 'E 0 a N m N C13> 0 C 7) Q w ,D O Q O Ta O ° o. 00 0 ° o Q < @ a m @ m a c• 0 0. c 0 o E V) N > y C Q O U 0 Q 0 rC 0 • o to O < < c- N 0 0 0 N a) m 0 c 5 c m O L 0 o m a N m g 'E U U c g E E a°) Q o m m c Cl) g a ° w E o > o r m m a) IQ 2 0 2 a m m a 5 ° ca. n n >. 0 o m 0 ro o o c a) a� o 2 m p w i C S] 7 _ u) V) 0 0 C Q C a) C -- w m o) E m a) m o 0 io m ° ° m <° c v v ° ac a a O m cmi o 0 c Q Z m o m` 0 a) 0 a) m — w m 2 c°n w ° > > > > O) 0 m 0 m S . m o c Q — ° o O Q C 0. o 0. o w E �° m o) E E -O -O m -2 -2 > > E 0E) E o c ° c - m ° o c m m 0. 0 o m rn , C C 0 0 ya o 0 z d Q 0. @ )O — — y) m m o. O O N .5 0 0 Q 0 0 = o N m 0 0 Q E c O R O v) a E E m 0 0 o E c L.. c c = 0 2 , pm . E = Cl) +, m n N 0 0 i '`) Q 0. 0 0 0 0 7 Y Y N m 0 0 0 L 0 0 Q ci) N N E • Q Q a) 0- 'o ° o o_ n- m m m 0 0 Y m ? m a. a E . E c Z 0. Q n m m 3 ° ' m m E E m m 0 _0 .° m m 0 En 0 a) c� o n. w m m E 2 E E E E E im m m 2 w a) E E E y w m Q Q E 0 O Q Q Q Q I'< v) N u) Q . N Q Q Q Q 4t m * `n m 2 0 rn Q 0 --i 0- a < Permit WQCSD0173 Owner-Facility Aqua North Carolina Inc Inspection Date 02/20/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine Is it accessible in all weather conditions? • ❑ ❑ ❑ #Is general housekeeping acceptable? • ❑ ❑ ❑ Are all pumps present'? • 0 p 0 Are all pumps operable'? ■ El ❑ ❑ Are wet wells free of excessive debris'? e 0 p 0 Are upstream manholes free of excessive debris/signs of overflow? • 0 0 ❑ Are floats/controls for pumps/alarms operable? • p ❑ El Is"auto polling"feature/SCADA present? ❑ ❑ I ❑ Is"auto polling"feature/SCADA operational'? ❑ ❑ ® ❑ Is simple telemetry present? I ❑ ❑ ❑ Is simple telemetry operational? ® 0 El ❑ Are audio and visual alarms present? I ❑ El 0 Are audio and visual alarms operable? ® ❑ El 0 Is the Pump station inspected as required? • ❑ El ❑ Are backflow devices in place'? ® ❑ ❑ ❑ Are backflow devices operable'? ® ❑ ❑ ❑ Are air relief valves in place'? ® 0 0 ❑ Are air relief valves operable'? ❑ ❑ ❑ I # Is an emergency generator available'? ® ❑ 0 ❑ Can the emergency generator run the pumps'? ® ❑ ❑ ❑ Is the pump station equipped for quick hook-up'? 0 ❑ ® El Is the generator operable'? ® ❑ ❑ 0 #Is fuel in tank and sufficient'? ® ❑ ❑ ❑ Is the generator inspected according to their schedule'? ® ❑ ❑ ❑ Is a 24-hour notification sign posted? ® 0 0 ❑ Does it include Instructions for notification'? ® El El ❑ Pump station identifier? NI 0 El ❑ Emergency phone number ® 0 ❑ ❑ Is public access limited'? ® ❑ ❑ ❑ Is pump station free of overflow piping'? ® ❑ ❑ El Is the pump station free of signs of overflow'? II ❑ ❑ ❑ Are run times comparable for multiple pumps? Yes Comment Page 7