Loading...
HomeMy WebLinkAbout20180328_NC0020940_CBIEPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0020940 18/03/13 B S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- D N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Murphy WWTP Payne St Murphy NC 28906 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 08:30AM 18/03/13 13/12/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Matthew Scott Helton/ORC/828-837-5035/ Other Facility Data 09:00AM 18/03/13 17/08/31 Name, Address of Responsible Official/Title/Phone and Fax Number Anna A Payne,PO Box 130 Murphy NC 289060130//828-837-2510/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 7B6AF94F-6494-4CD4-80BA-18A28D81037F 3/28/2018 3/28/2018 NPDES yr/mo/day 18/03/13 Inspection Type B3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 3/13/2018 and 3/15/2018, I (Daniel Boss) conducted Bioassay Inspections at the Town of Murphy WWTP. With the assistance of Scott Helton, I collected these effluent samples for use in a chronic ceriodaphnia dubia pass-fail toxicity test. The toxicity test passed for both the Division's sample and the sample analyzed by ETT Environmental. Toxicity test information follows: Test Type: 3-Brood Ceriodaphnia dubia chronic pass-fail Test Result: Pass Test Concentrations: 2.2% Control Survival: 100% Control Mean Reproduction: 25.3 neonates Test Treatment Survival: 100% Treatment Mean Reproduction: 25 neonates First Sample pH: 6.98 SU First Sample Conductivity: 336 micromhos/cm First Sample Total Residual Chlorine: <0.1 mg/L Second Sample pH: 6.83 SU Second Sample Conductivity: 331 micromhos/cm Second Sample Total Residual Chlorine: <.1 mg/L NC0020940 17 (Cont.) Page#2 DocuSign Envelope ID: 7B6AF94F-6494-4CD4-80BA-18A28D81037F Permit:NC0020940 Inspection Date:03/13/2018 Owner - Facility: Inspection Type: Murphy WWTP Bioassay Compliance Other Yes No NA NE Comment: Page#3 DocuSign Envelope ID: 7B6AF94F-6494-4CD4-80BA-18A28D81037F