HomeMy WebLinkAboutNC0026051_Authorization to Construct_20180321 ROY COOPER Governor ` MICHAEL S REGAN secretory M LINDA CULPEPPER Water Resources fnte,nn Director ENVIRONMENTAL QUALITY March 21, 2018 Ms. Stephanie Brixey Interim Deputy Director/POTW Director Durham County 5926 Highway 55 East Durham,North Carolina 27713 SUBJECT: Authorization to Construct A to C No. 026051A03 Durham County Triangle WWTP NPDES Permit No. NC0026051 Dear Ms. Brixey: A letter of request for an Authorization to Construct was received January 30,2018 by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 12 MGD Triangle WWTP, with discharge of treated wastewater into the Northeast Creek in the Cape Fear River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Replacement of existing four(4) 75 HP brush aerators in BNR Train No.2 with two (2)membrane disc diffuser systems and two (2) 125 HP rotary lobe blowers with VFD and minimum flow capacity of 1500 SCFM each at 9.2 psi,piping and controls; in conformity with the project plans, specifications, and other supporting documentation comprising the ATC Permit Application package submitted to the Department of Environmental Quality. In addition to the appropriate construction items approved in this Authorization to Construct,all other items stated in the application were deemed as maintenance events and require no approval. This ATC is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC00026051 issued effective December 1, 2011 and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0026051. State of North Carolma I Environmental Quality I Water Resources 512 N Salisbury Street 11617 Mail service Center I Raleigh,North Carolina 27699-1617 Phone 919 807 6300 Ms. Stepheme Brixey,Interim Deputy Director , March 21, 2018 Page 2 of 3 It is the Owner's responsibility to ensure that the as-constructed project meets the requirements of all applicable regulations and statutes, the ATC Permit Application package, and all of the requirements contained herein. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Raleigh Regional Office, telephone number 919-791-4200, shall be notified at least forty-eight(48)hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a Professional Engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit and the ATC Permit Application package. Mail the Certification to: Division of Water Resources, WQ Permitting — NPDES, 1617 Mail Service Center, Raleigh,NC 27699-1617. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the project plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the Permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. Ms. Stepheme Brixey, Intenm Deputy Director March 21, 2018 Page 3 of 3 You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. The issuance of this ATC does not preclude the Permittee from complying with any and all statutes,rules,regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. If you have any questions or need additional information, please contact Trupti Desai at telephone number(919) 807-6351. Sincerely, P.,(1),\) e_eivj i4-1,Linda Culpepper Interim Director, Division of Water Resources With Engineer's Certificate attached: cc: DWR Raleigh Regional Office, Water Quality Programs Central Files ecopy: Mr. Kurtis B. Proffit, P.E. Black &Veatch International Corporation Email: proffitkb@bv.com NPDES File Without Engineer's Certificate attached: cc: Durham County Health Durham County Triangle Wastewater Treatment Plant Authorization to Construct No. 026051 A03 March 21, 2018 NPDES Permit No.NC0026051 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina,having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the Triangle Wastewater Treatment Plant, located in Durham County,hereby state that,to the best of my abilities, due care and diligence was used in the observation of the following construction: Replacement of existing four (4) 75 HP brush aerators in BNR Train No.2 with two (2) membrane disc diffuser systems and two (2) 125 HP rotary lobe blowers with VFD and minimum flow capacity of 1500 SCFM each at 9.2 psi, piping and controls; in conformity with the project plans, specifications, and other supporting documentation comprising the ATC Permit Application package submitted to the Department of Environmental Quality. I certify that the construction of the above referenced project was observed to be built within substantial compliance, intent and in conformity with all applicable regulations and statutes and the project plans, specifications, and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature Registration No. Date Mail this Certification to: Attn: Trupti Desai Complex Permitting Unit DEQ/DWR/Water Quality Programs I) 1617 Mail Service Center Raleigh,NC 27699-1617