Loading...
HomeMy WebLinkAboutNC0032867_Renewal Application_20180307 ROY COOPER Governor MICHAEL S.REGAN Secretary Water Resources LLYDA CULPEPPER ENVtf QNMENTAL GIDALUTY interim Director March 07, 2018 Laeeq Khan, President Maliks International Inc 3425 Carmoustie Dr Chambersburg, PA 17202 Subject: Permit Renewal Application No. NC0032867 Kings Mountain Travel Plaza Cleveland County Dear Applicant: The Water Quality Permitting Section acknowledges the March 7, 2018 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, Wren Thedford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application (MRO) State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh,North Carolina 27699-1617 919-807-6300 - NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit INC003286 7 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box Otherwise,please print or type. ' 1. Contact Information: Owner Name Malik's International, Inc. Facility Name Kings Mountain Travel Plaza Mailing Address 400 Dixon School Road RECE)VtDI® NRI®WP. City Kings Mountain MAR ®7 2016 State / Zip Code NC 28086 Water Resources ' �'errn tong 5eCtinn Telephone Number (704)739-6415 • Fax Number (704) 739-0732 e-mail Address kingsmountain85@gmail.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 400 Dixon School Road City Kings Mountain State / Zip Code NC 28086 County Cleveland 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not refemng to the Operator in Responsible Charge or ORC) Name Malik's International Inc Mailing Address 3425 Carnoustie Drmve City Chambersbburg State / Zip Code PA 17202 Telephone Number (717)729-0249 Fax Number (717) 303-3481 e-mail Address kingsmountain85@gmail.corn 1 of 4 Form-D 11/12 NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ® Number of Employees 6 Residential ❑ Number of Homes School ❑ Number of Students/Staff , Other ❑ Explain Describe the source(s) of wastewater (example. subdivision, mobile home park, shopping centers, restaurants, etc.): Interstate truck stop with low to moderate activity Activities include small food service 8 hours per day, one men and one ladies restrooms, shower facilities with low use. These sources treated by small package plant. Stormwater runoff from diesel fuel dispensing area diverted to an oil/water separator before discharge to Number of persons served: approx 50 per day average-food service approx 20 per day 5. Type of collection system • 0 Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points two Outfall Identification number(s) 001, 002 Is the outfall equipped with a diffuser? 0 Yes ® No 7. Name of receiving stream(s) (NEW applicants:Provide a map showing the exact location of each outfall): 001 Dixon Branch, 002 Kings Creek 8. Frequency of Discharge: ® Continuous Outfall 001 ® Intermittent Outfall 002 If intermittent. Days per week discharge occurs: <1 for 002 Duration. storm event dependent 9. Describe the treatment system List all installed components, including capacities,provide design removal for BOD, TSS, nitrogen and ' phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. 2 of 4 Form-D 11112 Attachment to NPDES permit renewal KMTP February 28, 2018 Treatment plant description Section 9. Two 900 gal oil/grease traps - (Request removal from listing- see below) One splitter box for flow diversion with bar screen One 7,500 gal aeration basin with integral bar screen, two positive displacement blowers, clarifier with RAS and skimmer piping, contact chamber One 10,000 gal aeration basin with integral bar screen, two positive displacement blowers, clarifier with RAS and skimmer piping, contact chamber One 900 gal chlorine contact chamber-with tablet feeders for disinfection and de-chlorination One 900 gal aerobic digester- a septic tank of concrete construction One 900 gal holding tank- a septic tank of concrete construction One Flow measuring system comprised of a 22-1/2 degree v-notch weir and a Stevens Total Flow Meter with totalizer and chart recorder The oil/grease traps are septic tanks of concrete construction. They are part of the original construction and are now approximately 40 years old. On the last pumping of the contents, leaks were discovered in the horizontal seams of the tanks underground. The operators found that the typical anaerobic conditions in the septic tanks led to excessive ammonia passed to the aerobic systems without sufficient BOD to allow proper growth of activated sludge for good treatment. These units are currently by- passed. It is requested that their removal from the treatment train be considered. Additional data will be provided if required. The aeration basins and clarifiers are of steel construction and are a typical package plant design. The contact chambers listed were originally disinfection tanks with no means of de-chlorination and were replaced at some time in the past with the newer 900 gal chamber. These contact chambers are no longer used for chlorination. c � The 900 gal aerobic digester has an air line from one of the aeration basins. Wasted sludge is manually pumped to this unit as required. This unit was infrequently used in the past. Estimate of removal for the parameter are: BOD 90 to 95% Nitrogen 40 to 60% TSS 90 to 95% The adjustment of pH for the aeration basins is through manual addition of soda ash or lime. The disinfection tablets are sodium hypochlorite and a sulfide for de- chlorination. Waste sludge from the treatment plant and contents of the septic tanks has been handled through periodic pumping and removal by Wesson Septic Tank Service with disposal at the Cliffside Sanitary District in Rutherford County. Outfall 002 for this permit has stormwater treatment from the runoff area at the diesel dispensers via an oil/water separator. The oil/water separator is approximately 95 to 98% effective in removal of oil/grease and TSS. The City of Kings Mountain has conducted discussions with Malik's International Inc. (Kings Mountain Travel Plaza) for a lift station to connect to the existing City system but the cost appears to be prohibitive for this alternative. The City is considering building additional facilities in the area and taking on the flow from this plant. Additional information will become available during the period of review. • NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0 015 MGD Annual Average daily flow 0.001 MGD (for the previous 3 years) Maximum daily flow 0.005 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data NEW APPLICANTS:Provide data for the parameters listed Fecal Colzform, Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used If more than one analysis is reported, report daily maximum and monthly average If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading(Daily Maximum)and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters "N/A". Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BOD;) 38 27 mg/1 Fecal Coliform 100 52 #/ml Total Suspended Solids 20 15 mg/1 Temperature (Summer) 28 26 °C Temperature (Winter) 8 13 °C pH 8.0 7.8 su 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping(MPRSA) NPDES NC0032867 Dredge or fill(Section 404 or CWA) PSD (CAA) Other Non-attainment program (CAA) 1.4. APPLICANT CERTIFICATION certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Laeeq Khan President Pnnted name of Person Signing Title , Ojw @SA, \� Y Signature of Applicant Date February 28, 2018 North Carolina General Statute 143-215.6 (b)(2) states Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitonng device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by impnsonment not to exceed six months,or by both (18 U S C Section 10Ml provides a punishment by a fine of not more than$25,000 or impnsonment not more than 5 years,or both,for a similar offense) 4 of 4 Form-D 11/12