HomeMy WebLinkAboutNC0032867_Renewal Application_20180307 ROY COOPER
Governor
MICHAEL S.REGAN
Secretary
Water Resources LLYDA CULPEPPER
ENVtf QNMENTAL GIDALUTY interim Director
March 07, 2018
Laeeq Khan, President
Maliks International Inc
3425 Carmoustie Dr
Chambersburg, PA 17202
Subject: Permit Renewal
Application No. NC0032867
Kings Mountain Travel Plaza
Cleveland County
Dear Applicant:
The Water Quality Permitting Section acknowledges the March 7, 2018 receipt of your permit renewal application and
supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW
permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made.
Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.
The permit writer will contact you if additional information is required to complete your permit renewal. Please respond
in a timely manner to requests for additional information necessary to allow a complete review of the application and
renewal of the permit.
Information regarding the status of your renewal application can be found online using the Department of Environmental
Quality's Environmental Application Tracker at:
https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker
If you have any additional questions about the permit, please contact the primary reviewer of the application using the
links available within the Application Tracker.
Sincerely,
Wren Thedford
Administrative Assistant
Water Quality Permitting Section
ec: WQPS Laserfiche File w/application (MRO)
State of North Carolina I Environmental Quality I Water Resources
1617 Mail Service Center I Raleigh,North Carolina 27699-1617
919-807-6300
-
NPDES APPLICATION - FORM D
For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD
Mail the complete application to:
N. C. DENR / Division of Water Quality / NPDES Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
NPDES Permit INC003286 7
If you are completing this form in computer use the TAB key or the up - down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box Otherwise,please print or type. '
1. Contact Information:
Owner Name Malik's International, Inc.
Facility Name Kings Mountain Travel Plaza
Mailing Address 400 Dixon School Road RECE)VtDI® NRI®WP.
City Kings Mountain MAR ®7 2016
State / Zip Code NC 28086 Water Resources '
�'errn tong 5eCtinn
Telephone Number (704)739-6415 •
Fax Number (704) 739-0732
e-mail Address kingsmountain85@gmail.com
2. Location of facility producing discharge:
Check here if same address as above ❑
Street Address or State Road 400 Dixon School Road
City Kings Mountain
State / Zip Code NC 28086
County Cleveland
3. Operator Information:
Name of the firm, public organization or other entity that operates the facility. (Note that this is not
refemng to the Operator in Responsible Charge or ORC)
Name Malik's International Inc
Mailing Address 3425 Carnoustie Drmve
City Chambersbburg
State / Zip Code PA 17202
Telephone Number (717)729-0249
Fax Number (717) 303-3481
e-mail Address kingsmountain85@gmail.corn
1 of 4 Form-D 11/12
NPDES APPLICATION - FORM D
For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD
4. Description of wastewater:
Facility Generating Wastewater(check all that apply):
Industrial ❑ Number of Employees
Commercial ® Number of Employees 6
Residential ❑ Number of Homes
School ❑ Number of Students/Staff
, Other ❑ Explain
Describe the source(s) of wastewater (example. subdivision, mobile home park, shopping centers,
restaurants, etc.):
Interstate truck stop with low to moderate activity Activities include small food service 8 hours per
day, one men and one ladies restrooms, shower facilities with low use. These sources treated by small
package plant.
Stormwater runoff from diesel fuel dispensing area diverted to an oil/water separator before discharge
to
Number of persons served: approx 50 per day average-food service approx 20 per day
5. Type of collection system
• 0 Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer)
6. Outfall Information:
Number of separate discharge points two
Outfall Identification number(s) 001, 002
Is the outfall equipped with a diffuser? 0 Yes ® No
7. Name of receiving stream(s) (NEW applicants:Provide a map showing the exact location of each
outfall):
001 Dixon Branch, 002 Kings Creek
8. Frequency of Discharge: ® Continuous Outfall 001 ® Intermittent Outfall 002
If intermittent.
Days per week discharge occurs: <1 for 002 Duration. storm event dependent
9. Describe the treatment system
List all installed components, including capacities,provide design removal for BOD, TSS, nitrogen and '
phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a
separate sheet of paper.
2 of 4 Form-D 11112
Attachment to NPDES permit renewal KMTP February 28, 2018
Treatment plant description Section 9.
Two 900 gal oil/grease traps - (Request removal from listing- see below)
One splitter box for flow diversion with bar screen
One 7,500 gal aeration basin with integral bar screen, two positive
displacement blowers, clarifier with RAS and skimmer piping, contact chamber
One 10,000 gal aeration basin with integral bar screen, two positive
displacement blowers, clarifier with RAS and skimmer piping, contact chamber
One 900 gal chlorine contact chamber-with tablet feeders for disinfection and
de-chlorination
One 900 gal aerobic digester- a septic tank of concrete construction
One 900 gal holding tank- a septic tank of concrete construction
One Flow measuring system comprised of a 22-1/2 degree v-notch weir and a
Stevens Total Flow Meter with totalizer and chart recorder
The oil/grease traps are septic tanks of concrete construction. They are part of the
original construction and are now approximately 40 years old. On the last pumping of
the contents, leaks were discovered in the horizontal seams of the tanks underground.
The operators found that the typical anaerobic conditions in the septic tanks led to
excessive ammonia passed to the aerobic systems without sufficient BOD to allow
proper growth of activated sludge for good treatment. These units are currently by-
passed. It is requested that their removal from the treatment train be considered.
Additional data will be provided if required.
The aeration basins and clarifiers are of steel construction and are a typical package
plant design. The contact chambers listed were originally disinfection tanks with no
means of de-chlorination and were replaced at some time in the past with the newer
900 gal chamber. These contact chambers are no longer used for chlorination.
c �
The 900 gal aerobic digester has an air line from one of the aeration basins. Wasted
sludge is manually pumped to this unit as required. This unit was infrequently used
in the past.
Estimate of removal for the parameter are:
BOD 90 to 95%
Nitrogen 40 to 60%
TSS 90 to 95%
The adjustment of pH for the aeration basins is through manual addition of soda ash
or lime. The disinfection tablets are sodium hypochlorite and a sulfide for de-
chlorination.
Waste sludge from the treatment plant and contents of the septic tanks has been
handled through periodic pumping and removal by Wesson Septic Tank Service with
disposal at the Cliffside Sanitary District in Rutherford County.
Outfall 002 for this permit has stormwater treatment from the runoff area at the diesel
dispensers via an oil/water separator. The oil/water separator is approximately 95 to
98% effective in removal of oil/grease and TSS.
The City of Kings Mountain has conducted discussions with Malik's International Inc.
(Kings Mountain Travel Plaza) for a lift station to connect to the existing City system
but the cost appears to be prohibitive for this alternative. The City is considering
building additional facilities in the area and taking on the flow from this plant.
Additional information will become available during the period of review.
•
NPDES APPLICATION - FORM D
For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD
10. Flow Information:
Treatment Plant Design flow 0 015 MGD
Annual Average daily flow 0.001 MGD (for the previous 3 years)
Maximum daily flow 0.005 MGD (for the previous 3 years)
11. Is this facility located on Indian country?
❑ Yes ® No
12. Effluent Data
NEW APPLICANTS:Provide data for the parameters listed Fecal Colzform, Temperature and pH shall be grab
samples,for all other parameters 24-hour composite sampling shall be used If more than one analysis is reported,
report daily maximum and monthly average If only one analysis is reported, report as daily maximum.
RENEWAL APPLICANTS: Provide the highest single reading(Daily Maximum)and Monthly Average over
the past 36 months for parameters currently in your permit. Mark other parameters "N/A".
Parameter Daily Monthly Units of
Maximum Average Measurement
Biochemical Oxygen Demand (BOD;) 38 27 mg/1
Fecal Coliform 100 52 #/ml
Total Suspended Solids 20 15 mg/1
Temperature (Summer) 28 26 °C
Temperature (Winter) 8 13 °C
pH 8.0 7.8 su
13. List all permits, construction approvals and/or applications:
Type Permit Number Type Permit Number
Hazardous Waste (RCRA) NESHAPS (CAA)
UIC (SDWA) Ocean Dumping(MPRSA)
NPDES NC0032867 Dredge or fill(Section 404 or CWA)
PSD (CAA) Other
Non-attainment program (CAA)
1.4. APPLICANT CERTIFICATION
certify that I am familiar with the information contained in the application and that to the
best of my knowledge and belief such information is true, complete, and accurate.
Laeeq Khan President
Pnnted name of Person Signing Title
, Ojw @SA, \� Y
Signature of Applicant Date February 28, 2018
North Carolina General Statute 143-215.6 (b)(2) states Any person who knowingly makes any false statement representation, or certification in any
application, record, report, plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management
Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitonng device or method
required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be
guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by impnsonment not to exceed six months,or by both (18 U S C Section 10Ml
provides a punishment by a fine of not more than$25,000 or impnsonment not more than 5 years,or both,for a similar offense)
4 of 4 Form-D 11/12