APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
SECTION 1: INSTRUCTIONS AND INFORMATION
A. The Division of Water Resources will accept this application package for review only if all of the items are provided and the
application is complete. Failure to submit all of the required items will result in the application package being returned as incomplete
per 15A NCAC 02T .0105(b).
B. Plans and specifications must be prepared in accordance with 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute
133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES
Wastewater Treatment Facilities,
C. The plans and specifications submitted must represent a completed final design that is ready to advertise for bid.
D. Any content changes made to this Form ATC -12-14 shall result in the application package being returned.
E. The Applicant shall submit ONE ORIGINAL and ONE DIGITAL COPY (CD) of the application, all supporting documentation and
attachments. All information must be submitted bound or in a 3 -ring binder, with a Section tab for each Section, except the
Engineering Plans.
F. Check the boxes below to indicate that the information is provided and the requirements are met.
G. If attachments are necessary for clarity or due to space limitations, such attachments are considered part of the application
package and must be numbered to correspond to the item referenced.
H. For any project that requires review under the State Environmental Policy Act (SEPA), an Authorization to Construct cannot be
issued prior to the completion of a State Clearinghouse advertisement period for a FONSI, EIS, etc. unless the project qualifies for
a Determination of Minor Construction Activity.
I. For more information, visit the Division of Water Resources web site at: https://deg.nc.gov/about/divisions/water-resources/water-
resources-permits/wastewater-branch/npdes-wastewater/authorization-to-construct.
J. In addition to this Authorization to Construct, the Applicant should be aware that other permits may be required from other Sections
of the Division of Water Resources (for example: reclaimed water faces permits; Class A or B biosolids residuals permit).
SECTION 2: APPLICANT INFORMATION AND PROJECT DESCRIPTION
APPLICANT
Applicant's name Maury Sanitary Land District
Signature authority's name per 15A NCAC 02T .0106(b) L. A. Moye, Jr.
Signature authority's title Chairman
Complete mailing address P.O. Box 98, Maury, NC 28554
Telephone number (252) 747-2450
Email address cgm@mcdavid-inc.com
PROFESSIONAL ENGINEER
Professional
Engineer's name
Cecil G. Madden, Jr., P.E.
Professional
Engineer's title
Engineer
North Carolina Professional Engineer's License No.
0016359
Firm name
McDavid Associates, Inc.
Firm License
number
C-131
Complete mailing address
P.O. Box 1776, Goldsboro, NC 27533
PROFESSIONAL ENGINEER
Professional
Engineer's name
Cecil G. Madden, Jr., P.E.
Professional
Engineer's title
Engineer
North Carolina Professional Engineer's License No.
0016359
Firm name
McDavid Associates, Inc.
Firm License
number
C-131
Complete mailing address
P.O. Box 1776, Goldsboro, NC 27533
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 1
C.
Q
NVIROMMENTAL QUAL;
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
Telephone number
(919) 736-7630
Email address
cgm@mcdavid-inc.com
NPDES Permit number
NCO061492
Current Permitted flow (MGD) — include permit
0.225 MGD
flow phases if applicable
PROJECT DESCRIPTION
Provide a brief description of the project: The Operator currently adds alkalinity to the WWTP daily, by adding two 50 lbs bags of
lime to the oxidation ditch each day. In lieu of adding the lime manually. the operator will receive sodium hvdroxide in a liauid
form, at a new 3,000 gallon dual walled chemical holding tank. The 25% NaOH solution will be added to the WWTP via a
proposed chemical feed pump at the rate of 1.875 gallons per hour. The discharge from the chemical feed pump will be directed
to the existing return sludge pump station where the return sludge with chemical feed will be directed back to the mixed liquor
suspended solids in the existing oxidation ditch. There will be no other modifications to the treatment process.
SECTION 3: APPLICATION ITEMS REQUIRED FOR SUBMITTAL FOR ALL PROJECTS
A. Cover Letter
® The letter must include a request for the Authorization to Construct; the facility NPDES Number; a brief project description
that indicates whether the project is a new facility, facy mocation, treatment process mocation, or facy expansion;
the construction timeline; and a list of all items and attachments included in the application package.
❑ If any of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-31 North Carolina
General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment
Facilities are not met by the proposed design, the letter must include an itemized list of the requirements that are not met.
B. NPDES Permit
® Submit Part I of the Final NPDES permit for this facility that includes Part A (Effluent Limitations and Monitoring Requirements)
for the monthly average flow limit that corresponds to the work that is requested for this project.
C. Special Order by Consent
❑ If the facility is subject to any Special Orders by Consent (SOC), submit the applicable SOC.
® Not Applicable.
D. Finding of No Significant Impactor Record of Decision
❑ Submit a copy of the Finding of No Significant Impact or Record of Decision for this project.
❑ Provide a brief description of any of the mitigating factors or activities included in the approved Environmental Document
that impact any aspect of design of this project, if not specified in the Finding of No Significant Impact or Record of Decision.
® Not Applicable.
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 2
E. Engineering Plans
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
® Per 15A NCAC 02T .0504(c}(1), submit one set of detailed plans that have been signed, sealed and dated by a North Carolina
Licensed Professional Engineer.
® Per 21 NCAC 56.1103(a)(6), the name, address and License number of the Licensee's firm shall be included on each sheet of
the engineering drawings.
® Plans must be labeled as follows: FINAL DRAWING —FOR REVIEW PURPOSES ONLY —NOT RELEASED FOR CONSTRUCTION.
® 15A NCAC 02H .0124 requires multiple (dual at a minimum) components such as pumps, chemical feed systems, aeration
equipment and disinfection equipment. Is this requirement met by the design? ❑ Yes or ® No. if no, provide an
explanation: Currently the WWTP provides alkalinity by adding two 50 LB bags to the oxidation ditch per day. The chemical
feed pump is an easier alternative to handling two 50 lbs bags per day. If the pump goes out the operator can add the lime
by hand like he has been doing for several years.
Plans shall include:
® Plans for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate):
® Civil ❑ Not Applicable
® Process Mechanical ❑ Not Applicable
® Structural ❑ Not Applicable
❑ Electrical ® Not Applicable
❑ Instrumentation/Controls ® Not Applicable
❑ Architectural ® Not Applicable
❑ Building Mechanical ® Not Applicable
❑ Building Plumbing ® Not Applicable
® Plan and profile views and associated details of all modified treatment units including piping, valves, and equipment (pumps,
blowers, mixers, diffusers, etc.) Plan view of proposed chemical feed piping has been provided.
❑ Are any modifications proposed that impact the hydraulic profile of the treatment facility? ❑ Yes or ® No. If yes, provide
a hydraulic profile drawing on one sheet that includes all impacted upstream and downstream units. The profile shall include
the top of wall elevations of each impacted treatment unit and the water surface elevations within each impacted treatment
unit for two flow conditions: (1) the NPDES permitted flow with all trains in service and (2) the peak hourly flow with one
treatment train removed from service.
® Are any modifications proposed that impact the process flow diagram or process flow schematic of the treatment facility?
® Yes or ❑ No. If yes, provide the process flow diagram or process flow schematic showing all modified flow paths including
aeration, recycle/return, wasting, and chemical feed, with the location of all monitoring and control instruments noted.
F. ❑ Engineering Specifications *****(Specifications are clearly spelled out on the plans No additional specifications
are required) *****
❑ Per 15A NCAC 02T .0504(c)(2), submit one set of specifications that have been signed, sealed and dated by a North Carolina
Licensed Professional Engineer.
❑ Specifications must be labeled as follows: FINAL SPECIFICATIONS — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR
CONSTRUCTION.
Specifications shall include:
❑ Specifications for all applicable disciplines needed for bidding and construction of the proposed project (check as
appropriate):
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 3
❑ Civil
❑ Process Mechanical
❑ Structural
❑ Electrical
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
❑ Instrumentation/Controls
❑ Architectural
❑ Building Mechanical
❑ Building Plumbing
® Not Applicable (On plans)
® Not Applicable (On Plans)
® Not Applicable (On Plans)
® Not Applicable (On Plans)
®Not Applicable
❑ Detailed specifications for all treatment units and processes including piping, valves, equipment (pumps, blowers, mixers,
diffusers, etc.), and instrumentation. (On Plans)
❑ Means of ensuring quality and integrity of the finished product including leakage testing requirements for structures and
pipelines, and performance testing requirements for equipment. (On Plans)
❑ Bid Form for publicly bid projects. N/A Small Purchase
G. Construction Sequence Plan
® Construction Sequence Plan such that construction activities will not result in overflows or bypasses to waters of the State.
The Pian must not imply that the Contractor is responsible for operation of treatment facilities. List the location of the
Construction Sequence Plan as in the Engineering Plans or in the Engineering Specifications or in both: The proposed work
will cause no interruption of current operation. The operator will continue adding bagged lime until the chemical feed and
chemical storage tank are installed and operational.
H. Engineering Calculations ***** (Engineering design basis is attached) ***** Items listed below do not apply.
® Per 15A NCAC 02T.0504(c)(3),
submit one set of engineering calculations that have been signed, sealed and dated by a North
Carolina Licensed Professional Engineer; the seal, signature and date shall be placed on the cover sheet of the calculations.
For new or expanding facilities and for treatment process modifications that are included in Section 4.C, the calculations shall
include at a minimum:
❑ Demonstration of how peak hour design flow was determined with a justification of the selected peaking factor.
❑ Influent pollutant loading demonstrating how the design influent characteristics in Section 4.B.2 of this form were
determined.
❑ Pollutant loading for each treatment unit demonstrating how the design effluent concentrations in Section 4.B.2 of this form
were determined.
❑ Hydraulic loading for each treatment unit.
® Sizing criteria for each treatment unit and associated equipment (blowers, mixers, pumps, etc.) (Chemical Feed Pump and
chemical storage)
❑ Total dynamic head (TDH) calculations and system curve analysis for each pump specified that is included in Section 4.C.6.
❑ Buoyancy calculations for all below grade structures.
❑ Supporting documentation that the specified auxiliary power source is capable of powering all essential treatment units.
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 4
1.
3iVI ONMENTAL EiF'.'WzaL s{
Permits
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
❑ Provide the following information for each permit and/or certification required for this project:
Permit/Certification
Not
Applicable
Date
Submitted
Date
Approved
Permit/
Certification
Number
If Not Issued Provide
Status and Expected
Issuance Date
Dam Safety
X
Soil Erosion and Sediment Control
X
USCOE / Section 404 Permit
X
Water Quality Certification (401)
X
USCOE / Section 10
X
Stormwater Management Plan
X
CAMA
X
NCDOT Encroachment Agreement
X
Railroad Encroachment Agreement
X
Other.
X
Residuals Management Plan
❑ For all new facilities, expanding facilities, or modifications that result in a change to sludge production and/or sludge
processes, provide a Residuals Management Plan meeting the requirements of 15A NCAC 02T .0504(j) and 15A NCAC 02T
.0508; the Plan must include:
❑ A detailed explanation as to how the generated residuals (including trash, sediment and grit) will be collected, handled,
processed, stored, treated, and disposed.
❑ An evaluation of the treatment facility's residuals storage requirements based upon the maximum anticipated residuals
production rate and ability to remove residuals.
❑ A permit for residuals utilization or a written commitment to the Applicant from a Permittee of a Department approved
residuals disposal/utilization program that has adequate permitted capacity to accept the residuals or has submitted a
residuals/utilization program application.
❑ If oil, grease, grit or screenings removal and collection is a designated unit process, a detailed explanation as to how the
oil/grease will be collected, handled, processed, stored and disposed.
® Not Applicable. (This is an existing Facility. Changing the way alkalinity is added will not change sludge production.)
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 5
ZNVIL`tONifENTAL. QLis>i.ITY
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM A I 421=14)
SECTION 4: PR0IECT INFORMATION (N/A Not a New or Expanding Facility)
A. WASTEWATER TREATMENT PLANT FLOW INFORMATION —COMPLETE FOR NEW OR EXPANDING FACILITIES
1. Provide the following flow information:
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 6
Plant Flows
Existing
Plant Design
0.225 MGD
Current
NPDES Permit Limit
0.225 MGD
Current
(past 12
Annual Average
months)
MGD
For Past 12 Months:
Start Date: month/yr
End Date: month/yr
For Past 24 Months:
Start Date: month/yr
End Date: month/yr
Maximum
Month
MGD
MGD
Maximum
Day
MGD
MGD
Peak Hour
MGD
MGD
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 6
ENVIRONMENTAL OVAL: � y
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-Uml )
B. WASTEWATER TREATMENT FACILITY DESIGN INFORMATION —COMPLETE FOR NEW OR EXPANDING FACILITIES AND
FOR TREATMENT PROCESS MODIFICATIONS (N/A Not a New or Expanding Facility)
1. Have all of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina
General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment
Facilities been met by the proposed design and specifications? ❑ Yes or ® No. if no, provide justification as to why the
requirements are not met, consistent with 15A NCAC 02T .0105(n): Reliability is afforded by returning to bagged lime.
2. Provide the design influent and effluent characteristics that are used as the basis for the project design, and the NPDES
permit limits for the following parameters: Basis of design is presented outside of this document. See attachment. In
Summary, the Operator currently provides alkalinity to the WWTP by adding two 50 LBS bags of lime each day, at 7 days per
week. In lieu of 100 Ibs of lime we propose feeding the equivalent in a 25% solution of NaOH. 45 Gallons of 25% NaOH
provides the same alkalinity as 100 lbs of lime. (The table below does not apply.)
3. Based on the "Project Basis of Design" parameters listed above, will the proposed design allow the treatment facility to
meet the NPDES Permit Limits listed above? ®Yes or ❑ No. If no, describe how and why the Permit Limits will not be
met:
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 7
Project Basis of Design
Design Influent
Design Influent
Influent
Concentration
Load
Concentration -
(Must be
(Must be
Current Annual
supported by
supported by
Design Effluent
Average (past
Engineering
Engineering
Concentration and/or
NPDES Permit Limits
12 months) if
Calculations
Calculations
Load
(monthly average)
Parameter
Available
[Section 3.H])
[Section 3.H])
Ammonia Nitrogen
mg/L Summer
mg/L Summer
mg/L
mg/L
Ib/day
(NHs-N)
mg/L Winter
mg/L Winter
Biochemical
mg/L Summer
mg/L Summer
Oxygen Demand
mg/L
mg/L
Ib/day
(BODS)
mg/L Winter
mg/L Winter
Fecal Coliform
per 100 mL
per 100 mL
Nitrate + Nitrite
Nitrogen (NOs-N +
mg/L
mg/L
NO2-N)
Total Kjeldahl
mg/L
Nitrogen
mg/L
mg/L
Total Nitrogen
Ib/year
Ib/year
mg/L
mg/L
Total Phosphorus
mg/L
mg/L
Ib/day
Ib/year
Ib/year
Total Suspended
mg/L
mg/L
Ib/day
mg/L
mg/L
Solids (TSS)
3. Based on the "Project Basis of Design" parameters listed above, will the proposed design allow the treatment facility to
meet the NPDES Permit Limits listed above? ®Yes or ❑ No. If no, describe how and why the Permit Limits will not be
met:
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 7
vvul i Nps urces
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATG12-14)
4. Per 15A NCAC 021.0505(1), by-pass and overflow lines are prohibited. Is this condition met by the design? ®Yes or ❑ No
If no, describe the treatment units bypassed, why this is necessary, and where the bypass discharges:
5. Per 15A NCAC 02T .0505(k), multiple pumps shall be provided wherever pumps are used. Is this condition met by the
design? ❑ Yes or ® No. If no, provide an explanation: The backup for Chemical pump is to use bagged lime to provide
needed alkalinity.
6. Per 15A NCAC 02T .0505(1), power reliability shall be provided consisting of automatically activated standby power supply
onsite capable of powering all essential treatment units under design conditions, or dual power supply shall be provided
per 15A NCAC 02H. 0124(2)(a). Is this condition met by the design? ❑ Yes or ® No. If no, provide (as an attachment
to this Application) written approval from the Director that the facility: The existing WWTP was built in 1992, and was not
required to have standby power. If power goes out, the effluent will not discharge, because the effluent must be pumped.
The proposed modification in no way increases capacity of the WWTP. It merely reduces labor by providing a new way to
introduce alkalinity to the WWTP.
➢ Has a private water supply that automatically shuts off during power failures and does not contain elevated water
storage tanks, and
➢ Has sufficient storage capacity that no potential for overflow exists, and
➢ Can tolerate septic wastewater due to prolonged detention.
7. Per 15A NCAC 02T .0505(0), a minimum of 30 days of residual storage shall be provided. Is this condition met by the
design? ®Yes or ❑ No. If no, explain the alternative design criteria proposed for this project in accordance 15A NCAC
02T .105(n): This project brings no change to the sludge production or sludge management.
8. Per 15A NCAC 02T .0505(g)
, the public shall be prohibited from access to the wastewater treatment facilities. Explain how
the design complies with this requirement: The proposed chemical feed pump is located inside an existing chemical feed
room. The proposed chemical storage is inside a proposed dual walled spill containment tank. Both the puma and the
tank are inside the existing fenced in WWTP Site.
9. Is the treatment facility located within the 100 -year flood plain? ❑ Yes or ® No. If yes, describe how the facility is
protected from the 100 -year flood.
C. WASTEWATER TREATMENT UNIT AND MECHANICAL EQUIPMENT INFORMATION —COMPLETE FOR NEW OR
EXPANDING FACILITIES AND FOR MODIFIED TREATMENT UNITS
1. PRELIMINARY AND PRIMARY TREATMENT (i.e., physical removal operations and flow equalization):
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 8
Calculations
No. of
Plan Sheet
Specification
Treatment Unit
Type
Size per Unit
Provided?
Units
Reference
Reference
(Yes or No)
Manual Bar Screen
MGD at peak hourly flow
Mechanical Bar
MGD at peak hourly flow
Screen
Grit Removal
MGD at peak hourly flow
Flow Equalization
--
gallons
ft diameter; ft side
Primary Clarifier
Circular
water depth
Primary Clarifier
Rectangular
square feet; ft side
water depth
Other
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 8
ENVIRONMENTAL QUAI:�
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
SECONDARY TREATMENT (BIOLOGICAL REACTORS AND CLARIFIERS) (i.e., biological and chemical processes to remove
organics and nutrients)
2. TERTIARY TREATMENT
3.
Calculations
No. of
Plan Sheet
Specification
Treatment Unit
Type
Size per Unit
Provided?
Units
Reference
Reference
(Yes or No)
Aerobic Zones/
ft diameter; ft
Tertiary Clarifier
Circular
gallons
Tanks
series)
side water depth
Anoxic Zones/
Rectangular
square feet; ft
Tanks
(Gas;
gallons
Anaerobic
square feet
Zones/Tanks
tablet; liquid)
gallons
Sequencing Batch
--
gallons
Reactor (SBR)
Membrane
--
gallons
Bioreactor (MBR)
gallons
Secondary Clarifier
Circular
ft diameter; ft
side water depth
Secondary Clarifier
Rectangular
square feet; ft
side water depth
Other
2. TERTIARY TREATMENT
3.
DISINFECTION
Calculations
No. of
Plan Sheet
Specification
Treatment Unit
Type
Size per Unit
Provided?
Units
Reference
Reference
(Yes or No)
ft diameter; ft
Tertiary Clarifier
Circular
peak hourly flow;
series)
side water depth
Tertiary Clarifier
Rectangular
square feet; ft
(Gas;
side water depth
Tertiary Filter
square feet
Tertiary Membrane
tablet; liquid)
tank/unit
Filtration
square feet
Post -Treatment
Flow Equalization
--
gallons
Post -Aeration
gallons
Other
DISINFECTION
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 9
Calculations
No. of
Plan Sheet
Specification
Treatment Unit
Type
Size per Unit
Provided?
Units
Reference
Reference
(Yes or No)
gal/day per bank at
Ultraviolet Light
(Parallel; in
peak hourly flow;
series)
number of banks;
number of lamps/bank
(Gas;
gallons of contact
Chlorination
tablet; liquid)
tank/unit
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 9
4.
5.
6.
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM A I 42=44)
Dechlorination
No. of
(Gas;
gallons of contact
Plan Sheet
Specification
Calculations
Treatment Unit
TDH
tablets liquid)
tank/unit
Provided?
RESIDUALS TREATMENT
PUMP SYSTEMS (include influent, intermediate, effluent, major recycles, waste sludge, thickened waste sludge and plant
drain pumps)
Location
No. of
Purpose
Type
Plan Sheet
Specification
Calculations
Treatment Unit
TDH
Type
Size per Unit
Provided?
Units
Reference
Reference
(Yes or No)
Gravity Thickening
square feet; ft side
Tank
water depth
Mechanical
Thickening/
dry Ib/hour
Dewatering
Aerobic Digestion
gallons
Anaerobic
Digestion
gallons
Composting
dry Ib/hour
Drying
dry Ib/hour
Other
PUMP SYSTEMS (include influent, intermediate, effluent, major recycles, waste sludge, thickened waste sludge and plant
drain pumps)
Location
No. of
pumps
Purpose
Type
Capacity of
each pump
plan Sheet
Reference
Specification
Reference
GPM
TDH
MIXERS
Location
No. of
Mixers
Purpose
Type
Power of
eac( P)fixer
plan Sheet
Reference
Specification
Reference
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 10
7.
Q
BLOWERS
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-Izm 1l )
Location
No. of
Blowers
Purpose
Type
Capacity of
each Blower
(CFM
plan Sheet
Reference
Specification
Reference
Required from Nearest
Setback Parameter
Design? If "No", identify
Treatment/Storage
Setback Waivers in Item D.2
Unit
Below
Any habitable residence or place of assembly under separate
100 ft
® Yes
❑ No
ownership or not to be maintained as part of the project site
Any private or public water supply source
100 ft
® Yes
❑ No
Surface waters (streams — intermittent and perennial, perennial
50 ft
® Yes
❑ No
waterbodies, and wetlands)
ODOR CONTROL
No. of Plan Sheet Specification
Location Units Purpose Type Reference Reference
D. SETBACKS -COMPLETE FOR NEW WASTEWATER TREATMENT STRUCTURES
Chemical Solution Storage Tank and they comply with the setbacks.)
L.
(The only new items are the
The minimum distance for each setback parameter to the wastewater treatment/storage units per 15A NCAC 02T .0506(b)
are as follows:
2. Have any setback waivers been obtained per 15A NCAC 02T .0506(d)? El Yes or ®No. If yes, have these waivers been
written, notarized and signed by all parties involved and recorded with the County Register of Deeds? F1 Yes
Minimum Distance
Is Minimum Distance
Requirement met by the
Required from Nearest
Setback Parameter
Design? If "No", identify
Treatment/Storage
Setback Waivers in Item D.2
Unit
Below
Any habitable residence or place of assembly under separate
100 ft
® Yes
❑ No
ownership or not to be maintained as part of the project site
Any private or public water supply source
100 ft
® Yes
❑ No
Surface waters (streams — intermittent and perennial, perennial
50 ft
® Yes
❑ No
waterbodies, and wetlands)
Any well with exception of monitoring wells
100 ft
® Yes
❑ No
Any property line
50 ft
® Yes
❑ No
no, provide an explanation: None Are Required.
or ❑ No. If
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 11
ENVIRONMENTAL QUAL: i Y
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
SECTION 5: APPLICATION CERTIFICATION BY PROFESSIONAL ENGINEER
Professional Engineer's Certification per 15A NCAC 02T .0105:
I, Cecil G. Madden, Jr., P.E., attest that this application package for an Authorization to Construct
(Typed Name of Professional Engineer)
for the Maury Sanitary Land District WWTP —Contract No. 7 —Alkalinity Feed
(Facility and Project Name)
was prepared under my direct supervisory control and to the best of my knowledge is accurate, complete and consistent
with the information supplied in the engineering plans, specifications, calculations, and all other supporting
documentation for this project. I further attest that to the best of my knowledge the proposed design has been
prepared in accordance with all applicable regulations and statutes, 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina
General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design
Criteria for NPDES Wastewater Treatment Facilities, and this Authorization to Construct Permit Application, except as
provided for and explained in Section 4.13.1 of this Application. I understand that the Division of Water Resources'
issuance of the Authorization to Construct Permit may be based solely upon this Certification and that the Division may
waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this
application package. I further understand that the application package may be subject to a future audit by the Division.
Although certain portions of this submittal package may have been prepared, signed and sealed by other professionals
licensed in North Carolina, inclusion of these materials under my signature and seal signifies that I have reviewed the
materials and have determined that the materials are consistent with the project design.
I understand that in accordance with General Statutes 143-215.6A and 143-215.66, any person who knowingly makes
anY false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor,
which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal with written signature placed over or adjacent to the seal and dated:
Application for Authorization to Construct Permit (FORM ATC -12-14)
Page 12
Water Resources
ENVIRONMENTAL QUALITY
State of North Carolina
Department of Environmental Quality
sion of Water Resources
APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC -12-14)
SECTION 6: APPLICATION CERTIFICATION BY APPLICANT
Applicant's Certification per 15A NCAC 02T .0106(b)a
Move,lr., District Chairman, attest that this application package for an Authorization to Construct
(Typed Name of Signature Authority and Title)
for the Maury Sanitary Land District WWTP —Contract No.7 —Alkalinity Feed
(Facility and Project Name)
has been reviewed by me and is accurate and complete to the best of my knowledge. I also understand that if all
required parts of this application package are not completed and that if all required supporting information and
attachments are not included, this application package will be returned to me as incomplete. I further certify that in
accordance with 15A NCAC 02T .0120(b), the Applicant or any affiliate has not been convicted of environmental crimes,
has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all
appeals have been abandoned or exhausted, are compliant with any active compliance schedule, and does not have any
overdue annual fees.
I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based
solely upon acceptance of the Licensed Professional Engineer's Certification contained in Section 5, and that the Division
may waive the technical review of the plans, specifications, calculations and other supporting documentation provided
in this application package. I further understand that the application package may be subject to a future audit.
I understand that in accordance with General Statutes 143-215.6A and 143-215.6B any person who knowingly makes
any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor,
which may include a fine r)ot to exceed $10,000, as well as civil penalties up to $25,000 per violation.
Signature:
Date:
THE COMPLETED APPLICATION AND SUPPORTING INFORMATION SHALL BE SUBMITTED TO:
NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER RESOURCES/NPDES
By U.S. Postal Service
1617 MAIL SERVICE CENTER
RALEIGH, NORTH CAROLINA 27699-1617
By Courier/Special
Delivery:
512 N. SALISBURY STREET, 9TH FLOOR
RALEIGH, NORTH CAROLINA 27604
TELEPHONE NUMBER: (919) 807-6351
Application for Authorization to Construct Permit (FORM ATC -12-14) Page 13