Loading...
HomeMy WebLinkAboutNC0021628_Compliance Evaluation Inspection_20180301Water R esources ENVIRONMENTAL QUALITY ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director Marsh 5, 2018 Mr. John Mullis, Town Administrator Town of Norwood Post Office Box 697 Norwood, North Carolina 28128 SUBJECT: Reconnaissance Inspection Norwood WWTP NPDES Permit NCO021628 Stanly County, NC Dear Mr. Mullis: On March 1, 2018, Mr. Roberto Scheller of this Office conducted a reconnaissance inspection at the subject facility. Samples were collected from outfall pipe (#001) on the Rocky River for Total Residual Chlorine (TRC) to insure compliance with permit requirements and conditions. At the time of sampling TRC was tested as 50 ug/I. Please note that the Division shall consider all effluent TRC values reported below 50 ug/I compliant with permit conditions. Chlorination and dichlorination dosing should be evaluated in order to achieve a TRC of less than 50 ug/l. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact Roberto Scheller at (704) 235-2204 or roberto.scheller(a)ncdenr.gov . Sincerely, DocuSigned by: A14CC681 AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Officel 610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115 704 663 1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO021628 111 12 I 18/03/01 I17 18 i R i 19 LG] i 201 I 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 67 70 I I 71 I I 72 I r l u I� 73 I I 74 751 1 1 1 1 1 1 180 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 12:26PM 18/03/01 14/02/01 Norwood WWTP 6896 US Hwy 52 Exit Time/Date Permit Expiration Date Norwood INC 28128 01:36PM 18/03/01 19/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Darrell Horner/ORC/910-428-9052/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Dwight Smith,PO Box 679 Norwood NC 28128/Town Adminstrator/704-474-3416/7044743201 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Roberto Scheller MRO WQ//252-946-6481/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ 3/5/2018 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: j6l&� A14CC681 AF27425... Page# NPDES yr/mo/day Inspection Type NCO021628 111 121 18/03/01 1 17 18 1 p Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO021628 Inspection Date: 03/01/2018 Owner - Facility: Norwood WWTP Inspection Type: Reconnaissance Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: Total Residual Chlorine (TRC) sample were collected at point of discharge into the Rocky River (Outfall #001). At time of sampling TRC was measures at 50 ug/I. Page# 3