Loading...
HomeMy WebLinkAboutNCG500604_20180302_RECWater R esources ENVIRONMENTAL QUALITY 5 March 2018 Mr. Nakia Isler, Zone Production Manager Linde, LLC 3537 Fieldstone Trace Midland, North Carolina 28107 Dear Mr. Isler: ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director SUBJECT: Reconnaissance Inspection Linde, LLC NPDES Permit NCG500604 Cabarrus County, NC On March 1, 2018, Mr. Roberto Scheller of this Office conducted a reconnaissance inspection of the subject facility. Samples were collected from the outfall ditch for Total Residual Chlorine (TRC) to insure compliance with permit requirements and conditions. At the time of sampling, TRC was tested as 7 ug/I. Please note that the Division shall consider all effluent TRC values reported below 50 ug/I compliant with permit conditions. The enclosed reports should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself of Roberto Scheller at (704) 235-2204 or roberto.scheller@ncdenr.gov. Sincerely, DocuSigned by: A14CC681 AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Officel 610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115 704 663 1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCG500604 111 12 I 18/03/01 I17 18 i R i 19 LG] i 201 I 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ----------------------Reserved------------------- 67 70 I I 71 I I 72 I r l u ty 73 I I 174 751 1 1 1 1 1 1 180 I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10:34AM 18/03/01 16/04/25 Linde LLC 3537 Fieldstone Trace Exit Time/Date Permit Expiration Date Midland NC 28107 10:52AM 18/03/01 20/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Jay Naval, /Area Manager letters should be sent to him/704-888-3884/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Roberto Scheller MRO WQ//252-946-6481/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: 3/2/2018 A14CC681 AF27425... Page# NPDES yr/mo/day Inspection Type NCG500604 111 121 18/03/01 1 17 18 1 p Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCG500604 Inspection Date: 03/01/2018 Owner - Facility: Linde LLC Inspection Type: Reconnaissance Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: On March 1, 2018 at 10:42 am an effluent sample was collected from the end of discharge ditch. The sample was analyzed for Total Residual Chlorine (TRC) with a reading of 7 uq/I. Please note that the Division shall consider all effluent TRC values reported below 50 uq/I to be in compliance with the permit. Page# 3