HomeMy WebLinkAbout20180305_NC0000400_CBIDocuSign Envelope ID: ABA6574B-54CC-446A-BE7E-C872B87A729A Wa ter Resouf ces EHWROMMEWAl QUALITY March 05, 2018 Glenn Young The Quartz Corp USA PO Box 309 Spruce Pine, NC 28777 SUBJECT: Bioassay Inspection Report Quartz Corp / Pine Mountain WWTP NPDES WW Permit No. NC0000400 Mitchell County Dear Mr. Young: ROY COOPER Gorerna, AffCHAEL S. REGAN Sacre�� LT -NDA CFULPEPPER lnlerr m DireC10.- On 2/6/2018 & 2/8/2018, I conducted a Bioassay Compliance Inspection of the Quartz Corp/Pine Mountain WWTP. This inspection was conducted to split samples with the facility for the chronic Ceriodaphnia dubia toxicity tests, as well as Total Suspended Solids and Fluoride effluent limitations and monitoring requirements in NPDES WW Permit No. NC0000400. All samples were found compliant. Please respond in writing to this office within 30 days of the date of this letter regarding the following action item: Required Action Item: A file review of this facility revealed the wastewater treatment flow schematics submitted in the permit renewal are incorrect. An accurate wastewater treatment flow schematic shall be updated and submitted. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. ATTACHMENTS — Inspection Report Ec: Teresa Morris (email) WQS ARO Server Laserfiche Sincerely, DocuSigned b— Linda Wiggs,ivlDr�26r ental Senior Specialist Asheville Regional Office Division of Water Resources, NCDEQ State of North Carolina I Environmental Quality I Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 DocuSign Envelope ID: ABA6574B-54CC-446A-BE7E-C872B87A729A United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO000400 111 12 I 18/02/08 I17 18 L Q j 19 LG] 201 I 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 71 I 72n, 67 70 Iu I 73 I i74 751 I I I 1 80 Section B: Facility Data t Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 09:OOAM 18/02/08 12/06/01 Quartz Corp / Pine Mountain NC Hwy 226 N Exit Time/Date Permit Expiration Date Spruce Pine NC 28777 09:30AM 18/02/08 16/02/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Glenn D Young,PO Box 309 Spruce Pine NC 28777//828-765-9621/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Self -Monitoring Program 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs Ds ARO WQ//828-296-4500 Ext.4653/ DocuSigned by: Signature of Manageme t Q A Reviewer Agency/Office/Phone and Fax Numbers Date � L��r—��"_ 3/5/2018 17A38285848C... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: ABA6574B-54CC-446A-BE7E-C872B87A729A NPDES yr/mo/day Inspection Type Cont.) 1 NC0000400 111 121 18/02/08 1 17 18 JBI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The inspector, Linda Wiggs, met onsite with Teresa Morris on February 6th and 8th to split samples from the Quartz Corp composite sampler for toxicity and effluent parameters. This facility wastewater treatment units include basins. A rain event occurred prior to the February 8th sampling event. The reported flow for February 6th was 0.158 MGD and for February 8th was 0.333 MGD. Hence, stormwater flows effect these treatment units. The DWR samples Passed the chronic Ceriodaphnia dubia toxicity tests. The effluent parameter results were: 2/6/2018 TSS — 53 mg/I, 69 lbs./day Fluoride — 46 mg/I, 60.6 lbs./day 2/8/2018 TSS — 42.5 mg/I, 118 lbs./day Fluoride — 35 mg/I, 97 lbs./day Required Action: The wastewater treatment flow schematics submitted in the permit renewal are incorrect. These shall be updated and submitted to DWR. Page# 2 DocuSign Envelope ID: ABA6574B-54CC-446A-BE7E-C872B87A729A Permit: NC0000400 Inspection Date: 02/08/2018 Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Owner - Facility: Quartz Corp / Pine Mountain Inspection Type: Bioassay Compliance Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Split sampling was performed for toxicity and effluent parameters. Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page# 3