Loading...
HomeMy WebLinkAboutWQ0039825_Final Permit_20180223Permit Number W00039825 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer Jason robinson Coastal SWRule Permitted Flow 61,080 Facility Central Files APS _ SWP _ 2/23/2018 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Facility Name Ma/or/Minor Region Daniel Farm Subdivision Minor Raleigh Location Address County Johnston Facility Contact Affiliation Benson NC 27504 Owner Owner Name Owner Type Johnston County Public Utilities Government - County Owner Affiliation Chandra C Coats PE PO Box 2263 Dates/Events Smithfield NC 27577226 Scheduled Ong Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 2/26/2018 1 /8/2018 2/26/2018 2/26/2018 Regulated Activities Requested /Received Events Subdivision Additional information requested 2/14/18 Wastewater collection Additional information received 2/23/18 Outfall Waterbody Name Streamindex Number Current Class Subbasin Watei Resources En.noaniental Quality February 26, 2018 Chandra Farmer, P E , Director of Public Utilities Johnston County Public Utilities PO Box 2263 Smithfield, NC 27577 Subject Permit No WQ O',951 Daniel Farm Subdivision Wastewater Collection System Extension Permit Johnston County Dear Ms Farmer ROY COOPER Go l erf i of MICHAEL S REGAN Secreurrr LINDA CULPEPPER Interim Duceioi In accordance with your application received January 8, 2018, and additional information received on February 23, 2018, we are forwarding herewith Permit No WQ0039825 dated February 26, 2018, to Johnston county (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference Please pay particular attention to the following conditions contained within this permit Condition II 1 This permit shall not be automatically transferable, a permit modification request for a name change must first be approved by this office Condition II 4 Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T 0403 or any individual system -wide collection system permit issued to the Permittee It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215 6A through §143-215 6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699- 6714 Unless such demands are made, this permit shall be final and binding Division of Watei Resources, Raleigh Regional Office, Watei Quality Operations Section www ncwaterquality org 1628 Mail Sei vice Center, Raleigh, NC 27699_ 1628 Phone (919) 791-4200 Johnston County Public Utilities Permit No WQ0039825 If you need additional information concerning this matter, please contact Jason Robinson at (919) 791- 4200 or via e-mail at Jason T Robinson@ncdenr gov Sincerely, for Linda Culpepper Interim Director, Division of Water Resources by S Daniel Smith, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ cc Jerry T Dalton, PE of Dalton Engineering & Associates, PA Jdalton@daltonengineering com Johnston County Health Department Raleigh Regional Office Files Water Resources Central Files Page 2 of 8 North Carolina Department of Environmental Quality STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Johnston County Public Utilities Johnston County forthe construction and operation of approximately 12,278 linearfeet of 8-inch gravity sewer to serve 320 3+ bedroom homes and a swimming pool/clubhouse as part of the Daniel Farm Subdivision project, and the discharge of 61,080 gallons per day of collected domestic into Johnston County's existing sewerage system, pursuant to the application received January 8, 2018, and additional information received on February 23, 2018 and in conformity with 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated in March 2008, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable, and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit This permit shall be effective fro he da ' of issuance until rescinded and shall be subject to the specified conditions nd limitations co fined t ere n Linda Culpepper Interim Director, Division of Water Resources By Authority of The Environmental Management Commission Permit Number WQ0039825 Permit Issued February 26, 2018 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Johnston County Public utilities is hereby authorized to Construct, and then operate upon certification the aforementioned wastewater collection extension The sewage and wastewater collected by this system shall be treated in Johnston County's Regional Central Treatment Plant in accordance with Permit Number NC0030716 Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable, and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable, unless specifically mentioned herein Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below I. SPECIAL CONDITIONS No Special Conditions II STANDARD CONDITIONS 1 This permit shall not be transferaLle In the event there is a desire for the wastewater collection facilities to change ownership, or tnere is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate The approval of this request shall be considered on its merits and may or may not be app-oved [15A NCAC 02T 0104, G S 143-215 1(d3)] 2 This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit, 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable, and other supporting materials unless specifically mentioned herein [15A NCAC 02T 0110] 3 This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data [15A NCAC 02T 0110] 4 The wastewater collection facilities shall be properly maintained and operated at all times The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T 0403 If an individual permit is not required, the following performance criteria shall be met [15A NCAC 02T 0108(b)] Page 4 of 8 a The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards b A map of the sewer system shall be developed and shall be actively maintained c An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented d Pump stations that are not connected to a telemetry system shall be inspected every day (i e 365 days per year) Pump stations that are connected to a telemetry system shall be inspected at least once per week e High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented f A general observation of the entire sewer system shall be conducted at least once per year g Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B 0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215 1C h A Grease Control Program is in place as follows 1 For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems 2 For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative 3 Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows I Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility j Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system 5 The Permittee shall report by telephone to a water resources staff member at the Raleigh Regional Office, telephone number (919) 791-4200, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following Page 5 of 8 a Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc , or b Any SSO and/or spill over 1,000 gallons, or c Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300 Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur Part II of Form CS-SSO (orthe most current Division approved form) can also be completed to show that the SSO was beyond control [G S 143-215 1C(a1)] 6 Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State [15A NCAC 02T 0108(b)] 7 Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form A complete certification is one where the form is fully executed and the supporting documents are provided as applicable Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable Supporting documentation shall include the following a One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc b One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided Page 6 of 8 c Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form Prior to Certification (Final or Partial) Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation [15A NCAC 02T 0116] 8 Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation This shall be done through a permit modification with fee Such variance requests will be evaluated on a case -by - case basis Resolution of such request shall be evident prior to completing and submitting the construction certification [ 15A NCAC 02T 0105(n)] 9 A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities [15A NCAC 02T 0116] 10 Failure to abide by the conditions and limitations contained in this permit, 15A NCAC 2T, the Division's Gravity Sewer Design Criteria adopted February 12, 1996 and updated March 2008, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 and updated March 2008 as applicable, and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215 6A through §143-215 SC, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board [15A NCAC 02T 0104, 15A NCAC 02T 0108(b-c)] 11 In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities [15A NCAC 02T 0110, 15A NCAC 02T 0108(b)] 12 The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have Jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies [G S 143-215 1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Johnston County Public Utilities PERMIT #: WQ0039825 PROJECT- Daniel Farm Subdivision ISSUE DATE- February 26, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation It should be submitted in a manner that documents the Division's receipt Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a viola ion of the permit and shall subject the Permittee to appropriate enforcement actions The Permittee is responsible for tracking all partial certifications up until a final certification is received A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system perm,tted herein or portions thereof Printed Name, Title Signature ENGINEER'S CERTIFICATION Date I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 02T, the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated March 2008, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and updated March 2008, as applicable, and other supporting materials North Carolina Professional Engineer's Seal w/signature & date ❑ Final ❑ Partial (include description) Certification Comments/Qualifies (attach if necessary). D1� ision of Water Resources, Raleigh Regional Office, Watei Quality Opciatlons Section www newateiquality oig 1628 Mail Service Center, Raleigh NC 27699-1628 Phone (919) 791-4200 � 3 State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Didlsion� ai Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number W 0 t:1 100 Z. !� (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION 1 Applicant's name Johnston County Public Utilities (company, municipality, HOA, utility, etc ) 2 Applicant type ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3 Signature authority's name Chandra Fanner, P E per 15A NCAC 02T 0106(b) Title Director of Public Utilities 4. Applicant's mailing address Post Office Box 2263 City Smithfield State NC Zip 27577- 5 Applicant's contact information Phone number 919) 209-8333 Email Address chandra coats@johnstonnc com II. PROJECT INFORMATION: 1 Project name Daniel Farm Subdivision 2 Application/Project status ® Proposed (New Permit) ❑ Existing Permit/Project T If a modification, provide the existing permit number WQ00 and issued date Cd O O If new construction but part of a master plan, provide the existing permit number WQ00 y 3 County where project is located Johnston_ o G 6 aA 4. Approximate Coordinates (Decimal Degrees) Latitude 35 51790' Longitude -78 56850' 5 Parcel ID (if applicable) 13EO4003A � oA (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: Q U 1 Professional Engineer Jerry T Dalton, P E License Number 016282 Finn Dalton Engineering eering and Associates, P A Mailing address Post Office Box 426 City Cla on State NC Zip 27528- Phone number (919) 550-4740 Email Address jdalton n,daltonengineermg com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1 Facility Name Johnston County Regional Central Treatment Plant Permit Number NCO030716 Owner Name. Johnston County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1 Permit Number(s) WQ0017015 - 319 Commercial Park Downstream (Receiving) Sewer Size 8 inch System Wide Collection System Permit Number(s) (if applicable) WQCS00060 Owner Name(s) Johnston County FORM FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1 If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM DEV) been attached? ❑ Yes ❑No ®N/A 3 If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM HOA) been attached? ❑ Yes ❑No ®N/A 4 Origin of wastewater (check all that apply) ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5 Nature of wastewater 100 % Domestic/Commercial 0 % Commercial 0 % Industrial (See 15A NCAC 02T 0103(20)) 1Is there a Pretreatment Program in effect9 ❑ Yes ❑ No 6 Has a flow reduction been approved under 15A NCAC 02T 0114(f)? [�71 Yes 14 No ➢ If Yes, provide a copy of flow reduction approval letter 7 Summarize wastewater generated by project 8 Establishment Type (see 02T.0114(f)) Daily Design Flow "b No. of Units Flow single-family residential ( >/= 3-BR units) 320 gal/day 189 60,480 GPD swimming pool / clubhouse 10 gal/person 60 600 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 61,080 GPD a See 15A NCAC 02T 0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i e , minimum flow per dwelling, proposed unknown non-residential development uses, public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G S 42A-4) b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T 01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data Wastewater generated by project 61,080 GPD (per 15A NCAC 02T 0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why. ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain) FORM FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I Summarize gravity sewer to be permitted Size (inches) Length (feet) Material 8" 12,278 PVC ( Note Includes outfall ) ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1 Pump station number or name 2 Approximate Coordinates (Decimal Degrees) Latitude Longitude - 3 Design flow of the pump station millions gallons per day (firm capacity) 4 Operational point(s) of the pump(s) gallons per minute at feet total dynamic head (TDH) 5 Summarize the force main to be permitted (for this Pump Station) Size (inches) Length (feet) Material 6 Power reliability in accordance with 15A NCAC 02T 0305(h)(1) ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T 0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T 0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T 0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage FORM FTA 04-16 Page 3 of 5 t (. IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): Does the project comply with all separations found in 15A NCAC 02T 0305(fl & (g) ® Yes [:]No ➢ 15A NCAC 02T 0305(fl contains minimum separations that shall be provided for sewer systems Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water Imes (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX 2) 50 feet *Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T 0305(g) contains alternatives where separations in 02T 0305(f) cannot be achieved ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T 0305(fl or (g), see Section X of this application 2 Does the project comply with separation requirements for wetlands? (50 feet of separation) Kyes At No ➢ See the Division's draft separation requirements for situations where separation cannot be meet M\ ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected )N 3 Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B 02009 ® Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 2B 0202 4 Does the project comply with an individual 404 Permit or any 401 Certifications9 ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5 Does project comply with 15A NCAC 02T 0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc ) 6 Does this project include any sewer collection lines that are deemed "high-priority9" Per 15A NCAC 02T 0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer ❑ Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location) High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM FTA 04-16 Page 4 of 5 • 1. I t X. CERTIFICATIONS: 1 Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable9 ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review Approval of the request is required prior to submittal of the Fast Track Application and supportinIZ documents 2 Pi ofessional Engineer's Certification attest that this application for (Professional Engineer's name from Application Item III 1 ) has been reviewed by me and is accurate, complete and consistent with the information supplied to the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version) Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design NOTE — In accordance with General Statutes 143-215 6A and 143-215 613, any person who knowingly makes y false statement, representation, or certification in any application package shall be guilty of a Class 2 misdememay include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation (\ ano wh�zh ,etttttt1ttlt 0 ,' North Carolina Professional Engineer's seal, signature, and date: �.`� CAR Z ;4 • Q, 3 Applicant's Certification per 15A NCAC 02T 0106(b) MC attest that this application for (Signature Authority's name & title from Application Item 13 ) has been reviewed by me and is accurate and complete to the best of my knowledge I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution I will make no claim against the Division of Water Resources should a condition of this permit be violated I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete NOTE — In accordance with General Statutes 143-215 6A and 143-215 6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation Signature C . Date FORM FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality i iii ,lrt i Division of Water Resources &k anion of Water Re ,ouvze ry Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Johnston County Project Name for which flow is being requested: Daniel Farm Subdivision More than one FTSE may be required for a single project f the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County Regional Wastewater Facility b. WWTP Facility Permit #: NPDES NC 0030716 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 9.5 MGD 1.9311 5.9835 0.0611 7.9757 84% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow* * Current Avg Tributary Flow Plus (Name or Capacity, * (Firm / p fl, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** 319 0.1944 0.0778 0.0154 0.0791 0.0945-0.0168 Landfill 1.9296 1.9296 0.7642 0.7746 1.5388 0.3908 The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): 319 WWPS Downstream Permit Number: WQ0018085 Page 1 of 6 FTgR 04-1 F III. Certification Statement: I Chandra C. Farmer, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Date Page 2 of 6 FTSE 04-16 a7TaT PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section IIlwhere Available Capacity is < 0. Pump Station (Name or Number): Given that a. The pioportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 102 % and 0.07908 MGD of the Available Capacity (E) in Pump Station 319 ; and that j b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.04 MGD per year; and that i c. A funded Capital Project that will provide the required planned capacity, namely McGee's Crossroad Sewer Upgrade is in design or under construction with CS370560-16 ' planned completion in 2018 ; and/or d. The following applies: r The McGee's Crossroad Sewer Upgrade will divert flow fiom the McGee's WWPS to a new regional Middle Creel WWPS. This will free up capacity in the existing 6" forcemain that currently carries discharge from both the McGee's and 319 stations. Upon completion of the McGee's Sewer Upgrade, the 319 WWPS will bd upgraded to a higher pumping capacity. Therefore: i Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from {complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system R_C Signatztre Date Page 3 of 6 FTSE 04-16 Arrupimar `o��F WA �RQG Michael F. Easley, Governor William G Ross Jr, Secretary j L) r North Carolina Department of Environment and Natural Resources -i Y Alan W Klimek, P.E , Director QDivision of Water Quality May 18, 2005 Timothy Broome, PE, Director of Infrastructure and Engineering Johnston County Public Utilities PO Box 2263 Smithfield, NC 27577 Subject- Johnston County Residential Flow Reduction Approval Johnston County Dear Mr. Broome: On February 22, 2005, the Division of Water Quality received a flow reduction request for _ residences in Johnston County. The letter requests an allowable flow rate of 80 GPD per residential bedroom based on the evaluated data for three similar existing subdivisions. The water use data provided between November 2003 and October 2004 with daily readings taken during November 2004 was analyzed by central office and regional office staff with additional information requested. Based upon this data and the County response to our additional information requests, the Division hereby approves the use of 80 GPD per residential bedroom, with a minimum of 160 gpd for one and two bedroom units in all applicable non -discharge permit applications. Flow shall be incremented by 80/gpd for each bedroom above two. Regardless of the adjusted design daily wastewater flow rate at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facility or exceed the capacity of the sewers downstream of any new sewer extension or service connections) A permit modification and fee is required to apply this flow reduction to any existing permits where flows have been allocated. If you have any questions or comments regarding this matter, please contact Marie Doklovic at (919)733-5083 ext. 371. Sincerely, ,Alan W Klimek, P.E. cc: Ken Schuster, Raleigh Regional Office Barry Herzberg, Raleigh Regional Office Mark McIntire, NPDES East Program Kimberly Rineer, PE, Johnston County Public Utilities PERCS Flow Reduction File One 1 Pretreatment, Emergency Response and Collection Systems Unit Internet http //h2o enr nc state.us/ndpu NOrthCarollna 1617 Mail Servtce Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer va mAil k- Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper Dalton Engineering _ and Associates, P.A. January 3, 2018 Sub. Daniel Farm Subdivision Johnston County, North Carolina N.C.D.W.R. Fast -Track Application Developer: Daniel -Lan Development, L.L.C. 1029 Country Club Road Smithfield, North Carolina 27577 The Daniel -Lan Development, L.L.C. is planning a development for residential use consisting of 189 lots located on approximately 141.0 acres. Daniel Farm Subdivision is located within Johnston County, adjacent to NC Highway 210 and West of the intersection of NC Highway 210 and Interstate 40. The project will consist of the construction of roadway, to N.C.D.O.T. standards, that will provide access to the property. The improvements will consist of roadway with curb and gutter and storm drainage, sidewalks, a clubhouse/pool area, water utilities, and gravity sanitary sewer. The project is being proposed to be developed in multiple phases. However, the attached Fast -Track Application contains the flow and infrastructure for all of the proposed phases of Daniel Farm, and is being submitted for review and approval. If there are any questions, please do not hesitate to call. Thank you. Jo athan?:- 446 East Main Street — P.O. Box 426 — Clayton, NC 27528 — (919) 550-4740/Fax (919) 550-4741 Coat \ ' . ROBERrS �Fp IOA/p( Cem H/K/NG r ry RC / I y 2 OLD LEE RO P !' 0 . , Nimrod-Stephenm son Meorial Cem o " � r x m j\V �•� •" j S f j�`� rN RD A Stevenson Cem n o�qRR/SH FARM LM �y ''"�•t it }� Parrish Cem �\ �� O �WWATS70N RDBRADLEY DR�ENNIS RD�� \ o� � 3.0 M�CHAEL LN Ennis .>e'" Cem MCGe' 00 ROBER,r_ j, McGee Cem e f � f o CONNECT TO ooP t EXISTING SEWER UNE i 2 Coats x Cem u McGee -/" �.. Crossroads 7 h - r 2J G REENLEAF RD _,fir �itil'MlAE00, - — — � I1�1 GRAHAM POND RD -- " � � �• --- / _ r QUAD MAP Dalton Engineering (EDMONDSON, NC) 5Efi_ FOR and Associates, P. A. DANIEL FARM SUBDIVISION PLEASANT GROVE TOWNSHIP-JOHNSTON COUNTY, NC 446 East Main Street (919) 550-4740 P.O. Box 426 Fax (919) 550-4741 Clayton, NC 27520