Loading...
HomeMy WebLinkAbout20180282 Ver 1_401 Application_2018021820180282 CAROLINA 3040 NC Hwy 42 West; Clayton, NC 27520 ECOSYSTEMS, INCA P:919-359-1102 — F:919-585-5570 RECORD of DELIVERY Items Delivered: Cawford Townes Subdivision Buffer Authorization Request Delivery Location: 401 & Buffer Permitting Branch Date Delivered: _February 23, 2108 Intended Recipient: _Ms. Karen Higgins Delivered to: Signature gLguv r n -'i *4 3 2018 CAROLINA mCOSYST'EMS9 INC. 3040 NC Hwy 42 West; Clayton, NC 27520 P:919-359-1102 — F:919-585-5570 February 23, 2018 Ms. Karen Higgins, Supervisor 401 & Buffer Permitting Branch 512 N. Salisbury Street Archdale Building, 91h floor Raleigh, NC 27604 RE: Pre -Construction Notification: Riparian Buffer Authorization Crawford Townes Subdivision Franklin County, North Carolina Dear Ms. Higgins; Carolina Ecosystems, Inc., on behalf of the Crosswind Development and FLM Engineering, has prepared the attached Pre -Construction Notification (PCN) for the above referenced project for a Riparian Buffer Authorization. The site is located along Green Street in eastern Franklinton. The project would help to meet housing demands for residences in the Franklinton area of North Carolina. The attached PCN form provides information for your use in review of unavoidable impacts to riparian buffers. Two unnamed tributaries of Cedar Creek in the Tar River Basin occur on the property. A visit was conducted with the USACE on September 1, 2017, and their Preliminary Jurisdictional Determination (SAW -2017-01946) is attached. Both streams are depicted on Franklin County Soil Survey mapping, and flow across the property; neither are being contested. Avoidance and Minimization A total of four buffer impacts are associated with this property. Each impact area is identified on Figure 4. The first impact would be 2,156 square feet (.05 ac) for grading a vegetated swale in Zone two of Stream SB's buffer. The swale would direct stormwater into the stormwater BMP, most of which is located entirely outside of buffer areas. The second impact would be grading for the berm of the stormwater BMP and require 4,870 square feet (0.11 ac) of temporary impact to construct in Zone II, 1,672 (0.04) square feet of which would be permanently maintained herbaceous vegetation. The BMP Spillway would be lined with pervious, straw and coconut fiber reinforcement mat to promptly stabilize and preclude future erosion. The location of the BMP is fixed because it would receive stormwater from both valleys. The third impact would be for sanitary sewer connection to an existing manhole on the south side of Stream SA. The construction easement would be 35 -feet wide, and temporarily impact 3,296 square feet (0.08 ac) of Zone I and 1,396 (0.03 ac) square feet of Zone II. The permanent maintenance corridor, 20 -feet wide, would occupy 1,885 square feet (0.04 ac) in Zone I and 513 square feet (0.01 ac) in Zone II. The 20 -foot allowable width maintenance impact is requested for safety of maintenance crews. Both streams are about four feet wide, and incised eight feet. Crawford Townes Page 2 of 2 February 23, 2018 Two 24 square foot concrete piers, one on either side of the stream, would require temporary impacts in Zones I and II. The fourth impact would be for grading impacts in Zone II. This area would remain vegetated, but would require conversion of 1,114 (0.02 ac) square feet to herbaceous vegetation. Sediment and erosion control measures would be implemented according to NC requirements, and approved by NCDEQ prior to implementation. Jurisdictional areas adjacent to construction areas would be clearly marked with protection fencing or other similar method to avoid inadvertent encroachment. Copies of permits and impact areas would be provided to the prime contractor and all subcontractors working in or near jurisdictional areas. Land clearing would take place along with installation of erosion control devices. Construction would be accomplished using typical equipment including excavators, backhoes, and dump trucks. Additional equipment may be used as required. No future phases are planned. A Tier 1 search of the NC Natural Heritage Data Explorer found no records of federally protected species on or near the project. Their report is attached. If you have any questions or need additional information, please contact me at your earliest convenience at (919) 274-5979 or chris.hopper@carolinaeco.com. Sincerely, Carolina Ecosystems, Inc. Chris Hopper Senior Environmental Scientist cc: Mr. Andrew Williams, USACE, Raleigh Regulatory Field Office Attachments: - Pre -Construction Notification Form - Agent Authorization Form - USACE PJD (SAW -2017-01946) - NC Natural Heritage Program Search Report NCNHDE-5179 - Figures o Project Vicinity o USGS Map o Features Map o Buffer Impact Map - Crawford Townes Construction Plans (FLM Engineering) O�Q� W A TER�G O < Office Use Only: Corps action ID no. DWQ project no. Form Version 1.4 January 2009 Pre -Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ❑ Section 404 Permit ❑ Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: or General Permit (GP) number: 1c. Has the NWP or GP number been verified by the Corps? ❑ Yes ❑X No 1d. Type(s) of approval sought from the DWQ (check all that apply): ❑ 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ❑X Riparian Buffer Authorization 1 e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑X Yes ❑ No For the record only for Corps Permit: ❑X Yes ❑ No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑ Yes ❑X No 1g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. ❑ Yes ❑X No 1h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes ❑X No 2. Project Information 2a. Name of project: Crawford Townes 2b. County: Franklin 2c. Nearest municipality / town: Franklinton 2d. Subdivision name: Crawford Townes 2e. NCDOT only, T.I.P. or state project no: 3. Owner Information 3a. Name(s) on Recorded Deed: John William Pope Foundation 3b. Deed Book and Page No. 2016/396 3c. Responsible Party (for LLC if applicable): 3d. Street address: 4801 Six Forks Road, Ste 300 3e. City, state, zip: Raleigh, NC 27609 3f. Telephone no.: 3g. Fax no.: 3h. Email address: Page 1 of 10 PCN Form — Version 1.4 January 2009 4. Applicant Information (if different from owner) 4a. Applicant is: ❑ Agent ❑X Other, specify: Owner 4b. Name: 4c. Business name (if applicable): 4d. Street address: 4e. City, state, zip: 4f. Telephone no.: 4g. Fax no.: 4h. Email address: 5. Agent/Consultant Information (if applicable) 5a. Name: Chris Hopper 5b. Business name (if applicable): Carolina Ecosystems 5c. Street address: 3040 NC Highway 42 West 5d. City, state, zip: Clayton, NC 5e. Telephone no.: 919-274-5979 5f. Fax no.: 5g. Email address: chris.hopper@carolinaeco.com Page 2 of 10 B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): 1865-66-0607 1 b. Site coordinates (in decimal degrees): ILatitude: 36.1023 Longitude: -78.438 1 c. Property size: 6.9 acres 2. Surface Waters 2a. Name of nearest body of water to proposed project: Franklinton Branch 2b. Water Quality Classification of nearest receiving water: C;NSW 2c. River basin: Tar -Pamlico 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: Primarily residential with forested spaces interspersed. 3b. List the total estimated acreage of all existing wetlands on the property: 0 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 755 3d. Explain the purpose of the proposed project: To meet the growing population demands of Franklinton, NC 3e. Describe the overall project in detail, including the type of equipment to be used: See cover letter 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / project (includingall prior phases)in the past? ❑X Yes ❑ No ❑ Unknown Comments: 4b. If the Corps made the jurisdictional determination, what type of determination was made? ❑X Preliminary ❑ Final 4c. If yes, who delineated the jurisdictional areas? Name (if known): Chris Hopper Agency/Consultant Company: Carolina Ecosystems Other: 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. USACE PJD 'SAW -2017-01946' is attached. 5. Project History 5a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? ❑ Yes ❑X No ❑ Unknown 5b. If yes, explain in detail according to "help file" instructions. 6. Future Project Plans 6a. Is this a phased project? ❑ Yes ❑X No 6b. If yes, explain. Page 3 of 10 PCN Form — Version 1.4 January 2009 C. Proposed Impacts Inventory 1. Impacts Summary 1 a. Which sections were completed below for your project (check all that apply): ❑ Wetlands ❑ Streams — tributaries ❑ Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. Wetland impact number Permanent (P) or T 2b. Type of impact 2c. Type of wetland 2d. Forested 2e. Type of jurisdiction Corps (404,10) or DWQ (401, other) 2f. Area of impact (acres) —Temporary W1 Choose one Choose one Yes/No - W2 - Choose one Choose one Yes/No - W3 - Choose one Choose one Yes/No - W4 - Choose one Choose one Yes/No - W5 - Choose one Choose one Yes/No W6 - Choose one Choose one Yes/No 2g. Total Wetland Impacts: 2h. Comments: 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. Stream impact number Permanent (P) or Temporary (T) 3b. Type of impact 3c. Stream name 3d. Perennial (PER) or intermittent (INT)? 3e. Type of jurisdiction 3f. Average stream width (feet) 3g. Impact length (linear feet) S1 T Aerial Crossing SA PER DWQ 4 0 S2 Choose one S3 Choose one S4 Choose one S5 Choose one S6 Choose one 3h. Total stream and tributary impacts 0 3i. Comments: No impact to the stream will occur. The aerial crossing will be rested on concrete piers and clear span Stream SA. Page 4 of 10 PCN Form — Version 1.4 January 2009 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S. then indivii ually list all open water impacts below. 4a. Open water impact number Permanent (P) or T 4b. Name of waterbody (if applicable) 4c. Type of impact 4d. Waterbody type 4e. Area of impact (acres) —Temporary O1 Choose one Choose O2 Choose one Choose 03 - Choose one Choose 04 Choose one Choose 4f. Total open water impacts 4g. Comments: 5. Pond or Lake Construction If pond or lake construction proposed, the complete the chart below. 5a. Pond ID number 5b. Proposed use or purpose of pond 5c. Wetland Impacts (acres) 5d. 5e. Stream Impacts (feet) Upland (acres) Flooded Filled Excavated Flooded Filled Excavated P1 Choose one P2 Choose one 5f. Total: 5g. Comments: 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then vou MUST fill out Section D of this form. 6a. Project is in which protected basin? ❑ Neuse ❑X Tar -Pamlico ❑ Catawba ❑ Randleman ❑ Other: 6b. Buffer Impact number– Permanent (P) or T 6c. Reason for impact 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact (square feet) 6g. Zone 2 impact (square feet —Temporary B1 P Vegetated swale SB No 2,156 B2 T BMP Berm Impact Confluence: Both SA and SB No 4870 B3 P BMP Berm Impact Confluence: Both SA and SB No 1672 B4 T Sewerline Construction SA No 3296 1396 B5 P Sewerline Corridor SA No 1885 513 B6 P Grading SA No 1114 6h. Total Buffer Impacts: 1885 5,455 6i. Comments: Temporary impacts listed include permanent areas within them. Only permanent conversion impacts included in Total. Page 5 of 10 D. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. Location was selected to minimize the number of impacts that cross into the buffers. Final plans were designed after aquatic resources were identified with avoidance and minimization in mind. The stormwater BMP would remove 40 percent nitrogen and 35 percent phosphorus. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Best management practices and sedimentation and erosion control methods will be used during all construction techniques. No equipment refueling or maintenance activities will occur adjacent to aquatic resource areas. All temporary impacts during construction will be returned to their original configuration and seeded in a timely manner for stabilization. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ❑X No 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this project? ❑ Mitigation bank ❑ Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type: Choose one Type: Choose one Type: Choose one Quantity: Quantity: Quantity: 3c. Comments: 4. Complete if Making a Payment to In -lieu Fee Program 4a. Approval letter from in -lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: Choose one 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non -riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments: 5. Complete if Using a Permittee Responsible Mitigation Plan 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 6 of 10 PCN Form — Version 1.4 January 2009 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? ❑ Yes ❑X No 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. Zone 6c. Reason for impact 6d. Total impact (square feet) Multiplier 6e. Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). 6h. Comments: Page 7 of 10 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified Yes ❑ No within one of the NC Riparian Buffer Protection Rules? 1b. If yes, then is a diffuse flow plan included? If no, explain why. The proposed BMP is a storm water wetland, which removes 40% Nitrogen and 35% Phosphorous ❑ Yes Q No 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? 24.5% 2b. Does this project require a Stormwater Management Plan? ❑x Yes ❑ No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: NCDEQ will review the storm water plan. 2e. Who will be responsible for the review of the Stormwater Management Plan? NCDEQ 3. Certified Local Government Stormwater Review 3a. In which localgovernment's jurisdiction is thisproject? Town of Franklinton ❑ Phase II ❑x NSW 3b. Which of the following locally -implemented stormwater management programs ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: 3c. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No attached? 4. DWQ Stormwater Program Review E]Coastal counties ❑HQW 4a. Which of the following state -implemented stormwater management programs apply ❑ORW (check all that apply): ❑Session Law 2006-246 ❑Other: 4b. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No attached. 5. DWQ 401 Unit Stormwater Review 5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No 5b. Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No Page 8 of 10 PCN Form — Version 1.4 January 2009 F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) 1 a. Does the project involve an expenditure of public (federal/state/local) funds or the ❑ Yes ❑X No use of public (federal/state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ❑ No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1 c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval ❑ Yes ❑ No letter.) Comments: 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, ❑ Yes ❑X No or Riparian Buffer Rules (15A NCAC 2B .0200)? 2b. Is this an after-the-fact permit application? El Yes ❑X No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes ❑X No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy. If you answered "no," provide a short narrative description. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposedproject, or available capacity of the subject facility. A sanitary sewer will le constructed on site to tie to an existing manhole. Page 9 of 10 PCN Form — Version 1.4 January 2009 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat? ❑ Yes ❑X No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts? Yes ❑ No 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? USFWS website https:/twww.fws.gov/raleigh/species/cntylist/franklin.htmi. NC Natural Heritage Program GIS data updated October 2017. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ❑X No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? http:/hvww.habitat.noaa/gov/protection/efh/habitatmapper.htmi 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? ❑ Yes ❑X No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? HPOWEB Map Service http://gis.nedcr.gov/hpoweb/. National Register of Historic Places http://www.nps.gov/nr/research/. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain? ❑ YesX❑ No 8b. If yes, explain how project meets FEMA requirements: 8c. What source(s) did you use to make the floodplain determination? Franklin County GIS floodplain mapping, North Carolina Floodplain Mapping Program http:/twww.ncfloodmaps.com Applicant/Agent's Printed Name Date Applicant/Agent's Signature (Agent's signature is valid only if an authorization letter from the applicant isprovided.) Page 10 of 10 t ;AROUNA 3040 NC Hwy 42 West; Clayton, NC 27520 ECOSYSTEFMS, INC. P:919-359-1102 - F:919-585-5570 PROPERTY ACCESS AND AGENT AUTHORIZATION FORM Property Information Property Address and/or Description, Parcel Identification Number(s) (PIN) City: Franklinton NC Hwy 56 (E Green St), east of Franklinton 1865-66-0607 State: NC Property Owner Information County: Franklin Owner: ® Authorized Agent*: ❑ Name: Crosswind Development, Inc. Title: Bill Wynn, President Street Address: 7201 Creedmoor Road, Suite 147 City: Raleigh State:NC *Written proof of authorization from owner required. Authorization Property Size (Acres): 6.89 Zip Code: 27613 I, the undersigned, a duly authorized owner of record of the property/properties identified herein, do authorize representatives of the Wilmington District, U.S. Army Corps of Engineers (Corps) to enter upon the property herein described for the purpose of conducting on-site investigations and issuing a determination associated with Waters of the U.S. subject to Federal jurisdiction under Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. Additionally, I hereby grant Carolina Ecosystems, Inc. (CEI) staff, their designated contractors and representatives, as well as other Federal, State or local authorities access to the above referenced property when necessary for the purposes of conducting on-site environmental consulting services. I also grant CEI the authority to act as authorized agent on behalf of the owner of the above listed property for the communication, submission, and/or application to relevant government entities, including local, state, and federal authorities, for the review, acceptance, concurrence, and/or approval of environmental information, documents, and/or permit requests concerning the above listed property. These services may include regulatory determinations of environmental features on my property such as issuing a determination associated with streams and wetlands. I certify that I am the legal owner or authorized agent of the legal owner of the above property and have authority to grant such access. I have made CEI aware of, and supplied all available records related to, previous environmental investigations on the subject property of which I have knowledge. Owner/Agent (signature) - Date ,! f / U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW -2017-01946 County: Franklin County U.S.G.S. Quad: Franklinton NOTIFICATION OF JURISDICTIONAL DETERMINATION Property Owner/Applicant: Address: Telephone Number: Chris Hopper Carolina Ecosystems, Inc. 3040 NC Hwy 42 West Clayton, North Carolina 27520 919-359-1102 Size (acres) 6.9 (approximately) Nearest Waterway Billys Creek USGS HUC 03020101 Nearest Town Franklinton River Basin Pamlico Coordinates Latitude: 36.102436 Longitude: -78.437966 Location description: The site is located at 1208 E. Green Street, Franklinton, in Franklin County North Carolina. It is approximately 600 feet southwest of the East Green Street, Oak Ridge Road intersection. Indicate Which of the Following Apply: A. Preliminary Determination X There are waters on the above described property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). The waters have been delineated, and the delineation has been verified by the Corps to be sufficiently accurate and reliable. Therefore this preliminary jurisdiction determination may be used in the permit evaluation process, including determining compensatory mitigation. For purposes of computation of impacts, compensatory mitigation requirements, and other resource protection measures, a permit decision made on the basis of a preliminary JD will treat all waters and wetlands that would be affected in anyway by the permitted activity on the site as if they are jurisdictional waters of the U.S. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an appealable action, by contacting the Corps district for further instruction. _ There are wetlands on the above described property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). However, since the waters, including wetlands, have not been properly delineated, this preliminary jurisdiction determination may not be used in the permit evaluation process. Without a verified wetland delineation, this preliminary determination is merely an effective presumption of CWA/RHA jurisdiction overall of the waters, including wetlands, at the project area, which is not sufficiently accurate and reliable to support an enforceable permit decision. We recommend that you have the waters of the U.S. on your property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. B. Approved Determination _ There are Navigable Waters of the United States within the above described property subject to the permit requirements of Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403) and Section 404 of the Clean Water Act (CWA)(33 USC § 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. _ There are waters of the U.S., including wetlands, on the above described project area subject to the permit requirements of Section 404 of the Clean Water Act (CWA) (33 USC § 1344). Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. _ We recommend you have the waters of the U.S. on your property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. Page 1 of 2 SAW -2017-01946 _ The waters of the U.S., including wetlands, on your project area have been delineated and the delineation has been verified by the Corps. If you wish to have the delineation surveyed, the Corps can review and verify the survey upon completion. Once verified, this survey will provide an accurate depiction of all areas subject to CWA and/or RHA jurisdiction on your property which, provided there is no change in the law or our published regulations, may be relied upon for a period not to exceed five years. _ The waters of the U.S., including wetlands, have been delineated and surveyed and are accurately depicted on the plat signed by the Corps Regulatory Official identified below on . Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. There are no waters of the U.S., to include wetlands, present on the above described project area which are subject to the permit requirements of Section 404 of the Clean Water Act (33 USC 1344). Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. The property is located in one of the 20 Coastal Counties subject to regulation under the Coastal Area Management Act (CAMA). You should contact the Division of Coastal Management in Morehead City, NC, at (252) 808-2808 to determine their requirements. Placement of dredged or fill material within waters of the US, including wetlands, without a Department of the Army permit may constitute a violation of Section 301 of the Clean Water Act (33 USC § 13 l 1). Placement of dredged or fill material, construction or placement of structures, or work within navigable waters of the United States without a Department of the Army permit may constitute a violation of Sections 9 and/or 10 of the Rivers and Harbors Act (33 USC § 401 and/or 403). If you have any questions regarding this determination and/or the Corps regulatory program, please contact Andrew Williams at (919) 554-4884 or Andrew.E.Williams2r&usace.army.mil. C. Basis For Determination: See the attached Preliminary Jurisdictional Determination Form D. Remarks: None E. Attention USDA Program Participants This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the particular site identified in this request. The delineation/determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. F. Appeals Information (This information applies only to approved jurisdictional determinations as indicated in B. above) This correspondence constitutes an approved jurisdictional determination for the above described site. If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and request for appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the following address: US Army Corps of Engineers South Atlantic Division Attn: Jason Steele, Review Officer 60 Forsyth Street SW, Room 1 OM 15 Atlanta, Georgia 30303-8801 In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received at the above address by Not Applicable. **It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this correspondence. SAW -2017-01946 Corps Regulatory Official: Date: January 22, 2018 Digitally signed by WILLIAMSANDREW.F.1 244S61655 oL,USA, o=WIL Government, ou=1244 ou=PKI, du -USA, cn.=WILLIAMS.ANDREW.E.1244561655 Date: 2018.01.22 14:47:24 -05'00' The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete our Customer Satisfaction Survey, located online at http://corpsmapu.usace.armv.mil/cm apex/t?p=136:4:0. Copy Furnished: Bill Wynn, President Crosswind Development, Inc. 7201 Creedmoor Road, Suite 147 Raleigh, North Carolina 27613 Stephanie Z. Goss Environmental Senior Specialist North Carolina Department of Environmental Quality Division of Water Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609 I V1 _1111 --111 old, NOTIFICATION OF ADMINISTRATIVE APPEAL 011,� -I' IZFQLJE 0;R � A Applicant: Carolina Ecosystems File Number: SAW -2017-01946 Date: January 22, 2018 Chris Hopper Attached is: See Section below INITIAL PROFFERED PERMIT Standard Permit or Letter ofpermission)A PROFFERED PERMIT Standard Permit or Letter ofpermission)B PERMIT DENIAL C APPROVED JURISDICTIONAL DETERMINATION D PRF.,L,INIINARY JURISDICTIONAL, DF,TF,RMINATTON F., SI=C PION I - The following identifies your rights and options regarding an administrative appeal of the above decision. Additional infiormation may be found at llttp:/!tiVWv,y7.u5ace.armv.miff,iiietlfunetions�ewlcecwo/red or Corps regulations at 33 CFIR Part 331 A: INITIAL PROFI'ERI;D PI�RMIT: You may accept or object to the permit. • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section II of this form and return the form to the district engineer. Your objections must be received by the district engineer within 60 days of the date of this notice, or you will forfeit your right to appeal the permit in the future. Upon receipt of your letter, the district engineer will evaluate your objections and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as indicated in Section B below. B: PROFFERED PERMIT: You may accept or appeal the permit • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • APPEAL: If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. C: PERMIT DENIAL: You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section I1 of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. D: APPROVED JURISDICTIONAL DETERMINATION: You may accept or appeal the approved JD or provide new information. • ACCEPT: You do not need to notify the Corps to accept an approved JD. Failure to notify the Corps within 60 days of the date of this notice means that you accept the approved JD in its entirety, and waive all rights to appeal the approved JD. • APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. CAW 1mv_moAA E: PRELIMINARY JURISDICTIONAL DETERMINATION: You do not need to respond to the Corps regarding the preliminary JD. The Preliminary JD is not appealable. If you wish, you may request an approved JD (which may be appealed), by contacting the Corps district for further instruction. Also you may provide new information for further consideration by the Corps to reevaluate the JD. SECTION II - RE UEST FORAPPEAL or OBJECTIONS T(? AN INITIAL PROFFERED PERMIT REASONS FOIZ APPEAL OR OBJECTIONS: (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review of the administrative record, the Corps memorandum for the record of the appeal conference or meeting, and any supplemental information that the review officer has determined is needed to clarify the administrative record. Neither the appellant nor the Corps may add new information or analyses to the record. However, you may provide additional information to clarify the location of information that is already in the administrative record. POINT OF CONTACT FOR QUESTIONS_OR INFORMATION: If you have questions regarding this decision and/or the If you only have questions regarding the appeal process you may appeal process you may contact: also contact: District Engineer, Wilmington Regulatory Division, Mr. Jason Steele, Administrative Appeal Review Officer Attn: Andrew Williams CESAD-PDO 3331 Heritiage Trade Drive, Suite 105 U.S. Army Corps of Engineers, South Atlantic Division Wake Forest, North Carolina 27587 60 Forsyth Street, Room 10M15 Atlanta, Georgia 30303-8801 Phone: 404 562-5137 RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of Engineers personnel, and any government consultants, to conduct investigations of the project site during the course of the appeal process. You will be provided a 15 day notice of any site investigation, and will have the o ortuni to participate in all site investiations. Date: Telephone number: Signature of appellant oragent. For Permit denials, Proffered Permits and Approved Jurisdictional Determinations send this form: to: Division Engineer, Commander, U.S. Army Engineer Division, South Atlantic, Attn: Mr. Jason Steele, Administrative Appeal Officer, CESAD-PDO, 60 Forsyth Street, Room 10M15, Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 L�'� e► 51'� o Y�:A1M4�• North Carolina Department of Natural and Cultural Resources Natural Heritage Program Governor Roy Cooper January 26, 2018 Christopher Hopper Carolina Ecosystems Inc 3040 NC Hwy 42 W. Clayton, NC 27520 RE: Crawford Townes Dear Christopher Hopper: Secretary Susi H. Hamilton NCNHDE-5179 The North Carolina Natural Heritage Program (NCNHP) appreciates the opportunity to provide information about natural heritage resources for the project referenced above. A query of the NCNHP database, based on the project area mapped with your request, indicates that there are no records for rare species, important natural communities, natural areas, or conservation/managed areas within the proposed project boundary. Please note that although there may be no documentation of natural heritage elements within the project boundary, it does not imply or confirm their absence; the area may not have been surveyed. The results of this query should not be substituted for field surveys where suitable habitat exists. In the event that rare species are found within the project area, please contact the NCNHP so that we may update our records. The attached `Potential Occurrences' table summarizes rare species and natural communities that have been documented within a one -mile radius of the property boundary. The proximity of these records suggests that these natural heritage elements may potentially be present in the project area if suitable habitat exists and is included for reference. Tables of natural areas and conservation/managed area within a one -mile radius of the project area, if any, are also included in this report. Please note that natural heritage element data are maintained for the purposes of conservation planning, project review, and scientific research, and are not intended for use as the primary criteria for regulatory decisions. Information provided by the NCNHP database may not be published without prior written notification to the NCNHP, and the NCNHP must be credited as an information source in these publications. Maps of NCNHP data may not be redistributed without permission. The NC Natural Heritage Program may follow this letter with additional correspondence if a Dedicated Nature Preserve (DNP), Registered Heritage Area (RHA), Clean Water Management Trust Fund (CWMTF) easement, or Federally -listed species are documented near the project area. If you have questions regarding the information provided in this letter or need additional assistance, please contact Rodney A. Butler at rodney.butler ncdcr.aov or 919.707.8603. Sincerely, NC Natural Heritage Program MAILING ADDRESS: Telephone: (919) 707-8107 LOCATION: 1651 Mad Service Center www.ncnhp.org 121 West Jones Street Raleigh, NC 27699-1651 Raleigh, NC 27603 Natural Heritage Element Occurrences, Natural Areas, and Managed Areas Within a One -mile Radius of the Project Area Crawford Townes January 26, 2018 NCNHDE-5179 Element Occurrences Documented Within a One -mile Radius of the Project Area Taxonomic EO ID Scientific Name Common Name Last Element Group Status Observation Occurrence 5 -Very --- --- Date Rank Animal 32239 Waterbird Colony --- 2010-04-19 C Assemblage Significantly G3G4 S2? Dragonfly or 33749 Somatochlora georgiana Coppery Emerald 2004 -Pre H? Damselfly No Natural Areas are Documented Within a One -mile Radius of the Project Area No Managed Areas are Documented Within a One -mile Radius of the Project Area Accuracy Federal State Global State Status Status Rank Rank 5 -Very --- --- GNR S3 Low 5 -Very --- Significantly G3G4 S2? Low Rare Definitions and an explanation of status designations and codes can be found at https://nenhde.natureserve.org/content/helD. Data query generated on January 26, 2018; source: NCNHP, Q4 October 2017. Please resubmit your information request if more than one year elapses before project initiation as new information is continually added to the NCNHP database. Page 2 of 3 NCNHDE-5179: Crawford Townes J Pqb St .. W &I Ems" � 3r� W -G, aan•91 �"nmu,p�;atron Ur a�N 11 v �nklinton �� a �a ral,vw mid h, caa».r. o. Kemeoy s: a z Ah St r� M P Wter, \roF • F F Calkgn Sr ®� r, �' tJi ry rt } ®fM9NocM Ln �... C ba_A ht C happy January 26, 2018 Project Boundary Buffered Project Boundary Page 3 of 3 F;yl Mitchiners 1:21,792 0 0.175 0.35 0.7 mi 0 0.3 0.6 1.2 km Sources: Esn, HERE, DeLorme, Intarrnap, imement P Corp., GESCO, USGS, FAO, NPS, NRCAN, GeoBase, IGN, Kadastm NL, Ordnance Survey. Esn Japan, METI, Esn China (Hong Kong). s topo, MapnVindia, O OpenStreetMap conaiDulors, and the GIS User Community v If a G CD gillys Creek V 1 ami UBuf/a/o Creek 0 j r 56 1 C edar Creek Lat 36.1024 / Long -78.4377 Project Location: Franklin County Camp/ng Creek CAROLINA N Figure 1: ECOSYSTEMS Mile Q Study Area Vicinity Map 0 0.5 1 USGS Named Streams Crawford Townes February 2018 Franklin County, NC IC- 1Z 1 y "LA Y701 ST. 0 eA� A k- �m RTS �. yA-ST CAROLINA N Streams ECOSYSTEMS nmmmmm==== Feet 0 250 500 0 Study Area February 2018 Franklinton (2013) USGS 1:24K Quadrangle Map Crawford Townes Franklin County, NC Figure 2: USGS Map n � c� r = r � ✓' I Z r_ r= r 'C D, R 0 eA� A k- �m RTS �. yA-ST CAROLINA N Streams ECOSYSTEMS nmmmmm==== Feet 0 250 500 0 Study Area February 2018 Franklinton (2013) USGS 1:24K Quadrangle Map Crawford Townes Franklin County, NC Figure 2: USGS Map zB r Extends Offsite' Not Determined iZ4 �c Buffz Extencl, Offsite Origin Not Determined F7 a � . �T ,� 7 t • ASANDONEDEX. SAWTARY - - PROP. WINER MANHOLE(1VP(, I "�. _ - r I / t CONCRETE _ 1 1 EX FENCE AND EDGE OF ! WASHOUT PIT 1 1 CNW ASPHAL7 PAVEMENT 1 !. FgOAaT YARD O';W TSTCk PROP. LIM AND20OF STAGING, - 1 l STOCKPILE -AN AREA OCATED 5E wASHouS70RU RAINS NO 11 � � 1 11 FROM STORM DRAMS AND 1or f SURFACE WATERS PROP. i0' x 10D TEMPORARY i 7� II CONSTRUCTION ENTRANCE PROP. TEMPORARY DIVEISION 3_— (SEE PERMANENT SWALE 01 FOR CALCULATIONS) PROP. INLET -��- ALL SWALES AND �'1 TEMPORARY DIVERSION DITCHES J PROTECTION (TYP.) t - - -- -'- SHALL BE STA&LIZED WITHIN 7 DAYS(TYR 'I ! _- OFFRAN)QINTON- NlrarrrsEweR 1 EASEAIEN7 �� C&2 386• 380' PROP. SILT FENCE EX. CONCRETE PAD I 11n. f f _ CB -9 379 / AY F-WAYFitM82/N canvtr �) PROP CHECK DAM rea OR 11W PG 217 ( P 8, 2010, PG. 172- - f PYW 180.52.8270 mom II 1 PROP. TEMPORA DIVERSION 2 ( !� -7— / (SEEPERMANE SWALE 02 FOR CALCULA ALL SNALLSESTALES TEMPORARY WITHIN DIVERSION 7DAAYSS r!P.) 1 f f 7 ) , r \ f PROP- HORSESHOE I&N& Z lI \ �\ PROTECTION (TYP.)JOHVKILUAMPOPI FCUNDwn0N f \ \ OH7 \ I 0.8 2076, PG 3" \ \ PIAS 188686-2587 f \\\ , $ SKIMMER BASIN SLOPE• �\ MATTING TO BE NAG S75, OR APPROVED NlTARY SEINER LMIE (TYP)-x'17— EQUAL;SLOPES SHALL r AND ACATEWAL UN NOK" \ }X �` ( _ Cg. - BE STABILIZED WITHIN 7 - DAYS (TYP. o !! \ 7— `` ROP. AFF 3•, \ . A (TYP-) / v \\ \ r! 1 CBs'RANKL TY SAWITARV R` - �A\)////"`` '4_../Y FES -2 I.. ,1 PROP. CUT SLOPEfI TOBEGRADEDAT( xf \� EX S7REAN / -' - -� 2.51 STARTING AT JOHN WXUAM POPE fTYPJ� ^1�' 37 E.EYAl10N 3B8 FOUNDATION \ 4' - - I �I D.B. 2016, PG. 3" P. B. 7. PG. 5&59 RAW 1865-06-2472 PROP. PILLWAY 50'TAIWAMUCO —\\ �, --BERM ADEDA731) _ \ PoVER BUFFER FROM // TOP OF SWK(TYP) -A - N NOTIFICATION OF COMBINED SE Atp BELF-INSPECTION FORM P ER INY OUT 36S' CAROLINA N Carolina Ecosystems Impact Area Call -Outs Crawford Townes ECOSYSTEMS Over Partial Construciton Detail Sheet C-8 Franklin County, NC Figure 4: Buffer February 2018 No Scale Impact Areas PROP. WRAP DISSIPATOR THE SEDIMENTATION POLLUTION CONTROL ACT LENG :79 RESPONSIBLE FOR LAND DISTURBING ACTIVITIES s'MAKE WIDTH ' SURE THATTHE APPROVED EROSION AND '. DETAILING THE DOCUMENTATION OF THESE INC CLASS PRAP RI TH TO SIMPLIFY DOCUMENTATION OF SELFANSPEC I AND DEMUR DEVELOPED A COMBINED FORM.TH EX VARIABLFWIDTN \ WEEKLYSELF-ADHTORMPROONPF.RNA OF THE GRE6YWAYAram MaF FRANKLIN COUNTY `\ \ , \ ^- $ THE FOCUS OF THE BELF-SCTION REPORT EASEMENT \ \ \ ` ` ` SEDIMENTATION CONTROL MEASURES ALCOR DR 1188 PG. 217 -. \\ \\ • • • CONDUCTED AFTER EACH PHASE OF THE P.B. 2070, PG. 772 0 • • ABUSH .T FORM CAN ACCES DAT. PILAW 168&62-0270 \ \ - ( IFYO IAVE EST iS0 ANN ACC T AT 1916)791.47200. CAROLINA N Carolina Ecosystems Impact Area Call -Outs Crawford Townes ECOSYSTEMS Over Partial Construciton Detail Sheet C-8 Franklin County, NC Figure 4: Buffer February 2018 No Scale Impact Areas �N �o ¢m mz 3 ., BURLINGTON 9��0 MI LL RD �2 NC HWy 56 (E. GREEN ST) 2' ti o y w m SITE tiff �> y c2 tiw JN �4 y rc w m K �O �r � N N W 5 VICINITYMAP D CALL 48 HOURS BEFORE YOU DIG &A= NORTH CAROLINA ONE -CALL CENTER 1-800-632-4949 01017 THIS OMWING SW NOT- REPROWCEDIN WHOLE OP PART WNHWT WRRTEN PERMISSION a FLM ENGINEERING, INC CO N S T R U C T I N ENGINEERING O PLANS POST OFFICE BOX 81727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.61 0 .11)51 OR FIRM NC LICENSE NUMBER C-0222 po- *v, " CRAWFORD TOWNES REVISION HISTORY REV DESCRIPTION DATE It 1 ADDRESS NCDEQ COMMENTS 1/17/2018 2 ADDRESS NCDEQ 1/23/2018 COMMENTS 3 ADDRESS FCPU y12/2018 COMMENTS NC H WY 56 FRANKLINTON, NORTH CAROLINA PIN- 1865-66-0607 SHEET TITLE ORIGINAL PLAN SIZE: 24" X 36" C-1 COVER C-2 EXISTING CONDITIONS & DEMOLITION PLAN C-3 CALCULATIONS C-4 SITE PLAN C-5 UTILITY PLAN C-6 GRADING AND DRAINAGE PLAN ISSUED FOR C-7 EROSION & SEDIMENT CONTROL - PHASE 1 C-8 EROSION & SED IMENTCONTROL - PHASE 2 PERMITTING C-9 STORMWATER MANAGEMENT DETAILS DO NOT USE FOR CONSTRUCTION C-10 ROADWAY PLAN & PROFILE C-11 81 C-12 ROAD WIDENING PLAN C-13 - C-17 DETAILS DEVELOPER: CROSSWIND DEVELOPMENT, INC CONTACT: BILL WYNN 7201 CREEDMOOR ROAD, SUITE 147 RALEIGH, NC 27613 919-528-1347 BILL@WYNNHOMES.COM ENGINEER OF RECORD: FLM ENGINEERING, INC CONTACT: T. CHASE MASSEY, PE PO BOX 91727 RALEIGH, NC 27675 919.423.8975 CMASSEY@FLMENGINEERING.COM ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL TOWN OF FRANKLINTON, FRANKLIN COUNTY, NCDEQ AND NCDOT STANDARDS AND SPFnFl Tan SCALE ADJUSTMENT -SW 151 INCH IN LENGTH ON ORIGINAL DRAWING D t• 1 I IF IT M NOT 1 MCH ON THIS SHEET. -I TY )RSCALE GCORMNGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 COVER C-1 Crosswind %6 Development DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 COVER C-1 LEGEND NOTES 1. BOUNDARY AND TOPOGRAPHIC DATA PROVIDED BY CAWIHORNE, MOSS 8 PANCIERA, P.C. ON APRIL 07, 2017. 2. NO PORTION OF THIS PROPERTY LIES WITHIN A FEMA DESIGNATED 100 -YEAR FLOOD HAZARD AREA PER FEMA PANEL 3720186400K DATED APRIL 16, 2013 3. SURFACE WATERS ARE PRESENT WITHIN THE PROJECT AREA. STREAM AND WETLAND DELINEATION PERFORMED BY CAROLINA ECOSYSTEMS, INC. AND LOCATED BY CAWRIORNE, MOSS 8 PANCIERA, P.C. 4, THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A REPRESENTATION OF ALL UTILITIES WITHIN THE PROJECT EXTENT. UNDERGROUND UTILITY LOCATIONS, IF SHOWN ON THE PLANS, ARE BASED UPON THE BEST AVAILABLE INFORMATION AND SHOULD BE CONSIDERED ONLY AS APPROXIMATE. WHERE CONFLICTS OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO BEGINNING CONSTRUCTION. 5. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CAUL -CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. 6. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ALL UTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EX UTILITIES. 7, THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR THE REPAIR OF ANY EX. UTILITIES DAMAGED DURING CONSTRUCTION. 8. THIS PLAN IS NOT INTENDED AS A SUBSTITUTE FOR THE PERSONAL INVESTIGATION, INDEPENDENT INTERPRETATION, AND JUDGEMENT OF THE CONTRACTOR. 9. THE CONTRACTOR SHALL CONTACT THE ENGINEER AND THE COUNTY A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO THE BEGINNING OF CONSTRUCTION. CONNECTION TO THE EXISTING UTILITIES SHALL BE PERFORMED BY THE CONTRACTOR UNDER THE SUPERVISION OF THE COUNTY AND THE ENGINEER'S REPRESENTATIVE. 11. THE CONTRACTOR SHALL KEEP THE ENGINEER INFORMED RELATIVE TO THE PROGRESS OF THE CONSTRUCTION THE ENGINEER SHALL OBSERVE CONSTRUCTION ACTIVITIES AS REQUIRED BY NORTH CAROUNA GENERAL STATUTES 130A 317. FAILURE OF THE CONTRACTOR TO KEEP THE ENGINEER INFORMED MAY REQUIRE UNCOVERING OF WORK TO VERIFY COMPLIANCE WITH PLANS AND SPECIFICATIONS. ANY OST ASSOCIATED WITH UNCOVERING WORK AND/OR VERIFYING COMPLIANCE SHALL BE BORNE BY THE CONTRACTOR. 12. ALL EXCAVATED MATERIAL SHALL BE DISPOSED OF IN A LAWFUL MANNER. SOIL TYPES CeB2 - CECIL CLAY LOAM, 2 TO 6 PERCENT SLOPES, MODERATELY ERODED HeB- HELENA SANDY LOAM, 2 TO 6 PERCENT SLOPES WEC- WEDOWEE SANDY LOAM, 6 TO 10 PERCENT SLOPES LINE TABLE UNE LENGTH BEARING L-1 11.34' SBS° 54' 46.. W CURVETABLE EX. PROPERTY LINE - - EX. RIGHT -OF -WAV — — — EX. ADJACENT OWNERS ----------- EX. EASEMENT — EX. ROAD CENTERLINE -325- EX. MAJOR CONTOUR (5') -324 - - EX. MINOR CONTOUR IV) — — EX. CHANNEUSTREAM — EX. CHANNEUSTREAM BUFFER "" .I... ...... EX. SOIL LINE 0 EX. CHAIN UNK FENCE —OHW—OHW— EX. OVERHEAD ELECTRIC LINE — W — W EX. WATER LINE _SS — SS EX. SANITARY SEWER EX. TREE LINE NOTES 1. BOUNDARY AND TOPOGRAPHIC DATA PROVIDED BY CAWIHORNE, MOSS 8 PANCIERA, P.C. ON APRIL 07, 2017. 2. NO PORTION OF THIS PROPERTY LIES WITHIN A FEMA DESIGNATED 100 -YEAR FLOOD HAZARD AREA PER FEMA PANEL 3720186400K DATED APRIL 16, 2013 3. SURFACE WATERS ARE PRESENT WITHIN THE PROJECT AREA. STREAM AND WETLAND DELINEATION PERFORMED BY CAROLINA ECOSYSTEMS, INC. AND LOCATED BY CAWRIORNE, MOSS 8 PANCIERA, P.C. 4, THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A REPRESENTATION OF ALL UTILITIES WITHIN THE PROJECT EXTENT. UNDERGROUND UTILITY LOCATIONS, IF SHOWN ON THE PLANS, ARE BASED UPON THE BEST AVAILABLE INFORMATION AND SHOULD BE CONSIDERED ONLY AS APPROXIMATE. WHERE CONFLICTS OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO BEGINNING CONSTRUCTION. 5. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CAUL -CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. 6. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ALL UTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EX UTILITIES. 7, THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR THE REPAIR OF ANY EX. UTILITIES DAMAGED DURING CONSTRUCTION. 8. THIS PLAN IS NOT INTENDED AS A SUBSTITUTE FOR THE PERSONAL INVESTIGATION, INDEPENDENT INTERPRETATION, AND JUDGEMENT OF THE CONTRACTOR. 9. THE CONTRACTOR SHALL CONTACT THE ENGINEER AND THE COUNTY A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO THE BEGINNING OF CONSTRUCTION. CONNECTION TO THE EXISTING UTILITIES SHALL BE PERFORMED BY THE CONTRACTOR UNDER THE SUPERVISION OF THE COUNTY AND THE ENGINEER'S REPRESENTATIVE. 11. THE CONTRACTOR SHALL KEEP THE ENGINEER INFORMED RELATIVE TO THE PROGRESS OF THE CONSTRUCTION THE ENGINEER SHALL OBSERVE CONSTRUCTION ACTIVITIES AS REQUIRED BY NORTH CAROUNA GENERAL STATUTES 130A 317. FAILURE OF THE CONTRACTOR TO KEEP THE ENGINEER INFORMED MAY REQUIRE UNCOVERING OF WORK TO VERIFY COMPLIANCE WITH PLANS AND SPECIFICATIONS. ANY OST ASSOCIATED WITH UNCOVERING WORK AND/OR VERIFYING COMPLIANCE SHALL BE BORNE BY THE CONTRACTOR. 12. ALL EXCAVATED MATERIAL SHALL BE DISPOSED OF IN A LAWFUL MANNER. SOIL TYPES CeB2 - CECIL CLAY LOAM, 2 TO 6 PERCENT SLOPES, MODERATELY ERODED HeB- HELENA SANDY LOAM, 2 TO 6 PERCENT SLOPES WEC- WEDOWEE SANDY LOAM, 6 TO 10 PERCENT SLOPES LINE TABLE UNE LENGTH BEARING L-1 11.34' SBS° 54' 46.. W CURVETABLE CURVE LENGTH RADIU9 CHORD BEARING C-1 417.66' 2006.88' 418.90' N 81' 22' 38" W CALL 48 HOURS BEFORE YOU DIG NORTH CAROLINA ONE -CALL CENTER 1-800-632-4949 THIS DMWe1G SHALL NOT BE REE—UCEO IN —1-1 IITHOUT WRRTEN PERMIESgN - FLM ENGINEERING, EX HYDRANT EX UTILITY POLE (Typ) EX FIBER OPTIC MARKER (TYP) - _ � _ _ NC /y" 397!!' -_�-- - =\ _ =Q° pUeL/ H RO�N s n ON EX 16* LOCATION OF 01, (DEPTH UNKNOWN) 3951 RRS w� � y� _ EX CURB 8 GUTTER 18`RCP INV. IN = 38919' EX. CONCRETE 2222... .. Ofj _ *�00. (TYP) ABANDONED EX SANITARY PAD SEWER MANHOLE/ / 1 w\ ` TOWN OF FRANKLINTON 20' 1 1 / i i EX SANITARY SEWER MANHOLE \ :Y SANITARY SEWER EASEMENT�1 / i 7 i TOP -397 12' ... _ INV =39115' C3 w��'CHW �... \�' \ W / J� EX OVERHEAD POWER UNE 'l i EX SANITARY SEWER MANHOLE (TO BE REMOVELYRELOATED) - 1 I TOP =396.07' w \ EX FENCE AND EX. INV = 39010' \� 152.22• 111 1/PARKING ENCROACHMENT 1 Ce82 401 2 pCP / NIP W i ✓ «Y 3 DI'I \ S64'53.36'E TOWN OF FRANKLINTON O / 20' SANITARY SEWER / —_ - ��' 395' EASEMENT u` o I I \ EX ASPHALT - 390' - 1n I / (TO BE REMOVED) EX TREEL/NE (TP) / I 1 TOWN OF FRANKLINTON / I I 20' SAN/TARY SEWER - / / 385' I EASEMENT WF l �I JOHN WILLIAM POPE l 1 FOUNDATION / JJJ D.B. 2016, PG, 398 P B. 7, PG. 57 8 �Y ED / j! 360' PINM 186566-3841 / I 5 I / (TORFUO VED�NT / PERKINSON WAYc FRANKLnOUNTYEX FENCE 2s / 40'PUBLIl I (TO BE REMOVED) RIGHT-OF-WAY I l . 1198, PGEX 50 TAR/PAML/CO RIVER P.B. 2010, PO. 172 . 217 CONCRETE BUFFER FROM TOP OF BANK /p \ 3 175 � � I / P/AM11B65-52-9270 36 5•PAD I I 390 B / I EX. SAN/TARY SEWER MANHOLE I TOP = 37532' \ I INV. IN T366 6' \ I I III INV OUT=363s1.15' / I wecI I \ I WF JOHN WILLIAM POPE I Q \ \ \ J ( FOUNDATION \ V \ \ \ 370' I EX BUFFER ROM TOP F VERBAN ` D.B. 1865 66-2 396 Y v BUFFER FROM TOP OF BANK � � � o, `'' P/NM 186566.2587 O j \ \ mCID Q I EX STREAM\ EX. SANITARY SEWER LINE (TYPJ 1 - / L _ J (SIZE AND MATERIAL UNKNOWN) \ ... I \ NlP �-- — — — — I - � f o 365' o_ \ f .EIP t I WF I I ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 A,3 ez g'T1, 80HJIM REVISION HISTORY REV DESCRIPTION GATE BY M 1 ADDRESS NCDEQ 1/12/2018 FLM COMMENTS 2 ADDRESS NCDEO 1/23/2018 FLM COMMENTS 3 ADDRESS FCPU y12/2018 FLM ORIGINAL PLAN SIZE: 24" X 36' ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 40 20 0 40 SCALE. 1 INCH = 40 FEET SCALE ADJUSTMENT THIS BAR IB 1 INCH IN LENGTH W ORKILUL DRAWING 1 11 IF IT M NOT 1 INCH ON THBB SHEET,AACJUST Y W R BCALE CCOR—GLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 \ \ n JO HN WILLIAM POPE I I 370' / I FOUNDATION B. 2016, PG. 396 P B. 7, PG. 58-59 P/N# 1865-66-2472 \\ \ WBC \ ! \\ \ \\\� EX. CREEK I ' l I I %,00 Crosswind evelopment \\VL \ I OF48393 - - 383, TQ7� 417� I -_ _/ T52• `\ \S \\ HeB l EIP -- — — — I DATE: 12-07-2017 EX SANITARY SEWER \� �• �, // SCALE: ASSHOWN MANHOLE \ ✓l DESIGNED BY: FLM NV IN=362.83' TOP = 370.83' \ �P T \ APPROVED BY: FLM VARIABLE WIDTH --/ INV OUT= 362.23' /\ GREENWAY/UTILITY _ \ ' _1 £ ' / I PROJECT NO.: 17022 EASEMENT \\ .\I.,. _� ___/ 5 / V P.B. 2010. PG. 172 N� _ _ _ _ \\ \ �/7 ANDREW W 6 FRANKLIN COUNTY 1 \ - Sry. `5 I KA/TLYN A. TROTTER I EXISTING CONDITIONS & DB. 1198, PG. 217 a23'E F; D.B. 1975, PG. 943 I DEMOLITION PLAN 6841. PB. 7. PG. 58-59 I P.B. 2D10,PO.172 pp \`\`� P P/NM 186566-2297 PIN# 1865-52-9270 TOWN OF FRANKUNTON \ ll' \ � _ _ _ _ V I 20' SANITARY SEWER /� _ { _ /� EASEMENT \\\\\\\ `\��/ :.'1 EIP I I \/�/__ 2 SHEET 2 OF17 SWALE NUMBER 1A 1B 1 C RUNOFF 10 -YEAR COEFFICIENT INTENSITY (iNhr) 0.85 727 0.85 727 0.65 7.27 0.65 1 7.27 1 DRAINAGE AREA (sf) 73505.00 5104.00 9292.00 674.00 DRAIN' -r APl.. (acres) 0.31 0.12 0.21 0.02 lots) 1.47 0.55 1.01 0.07 ( )` 1.47 2.02 3.03 3.10 CRAWFORD TOWNES-STORM DRAINAGE CALCULATIONS LOWER INVERT 391.00 382.50 374.25 374.00 LENGTH IR) 239.00 74.00 101.00 13.00 CRAWFORD TOWNES- PERMANENT SWALE CALCULATIONS CHANNEL BOTTOM FORE BACK CHANNEL CHANNEL SECTION WIDTH SLOPE, SLOPE, DEPTH SLOPE (R) Z:1 (ft) Z:1 (R) (R) (Mft) TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.039 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.081 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.085 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.013 NORMAL DEPTH (R) 041 0.31 0.38 0.51 FREEBOARD (R) 0.59 0.89 0.82 0.49 SHEAR gTRE33 ((ytt2) 1.00 1.57 2.02 0.41 VELOCITY (APs) 177 3.67 4.09 2.67 STRUCTURE NUMBER Cc I A A Tc O O 386.00 379.50 374.50 373.50 373.00 371.00 389.00 125.00 119.00 54.00 98.00 18.00 108.00 30.00 TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.096 0.055 0.093 0.010 0.028 0.019 0.067 0.18 0.32 0.40 047053 0.46 0.57 0.47 0.82 0.88 0.80 0,54 0.43 0.53 RUNOFF 10 -YEAR DRAINAGE DRAINAGE TIME OF AREA 325 TOTAL OPoFlCE RADIUS OPoFlCE LENGTH CHANNEL BOTTOM IA C Im INTENSITY( ) COEFFICIENT SFICFS FROM TO COEFFICIENT INTENSITY AREA AREA CONCENTRATION FLOW FLOW SLOPE Dtheo SIZE VNII PIPE UPPER LOWER HOOD 6,948 2 _ pNhr) (at) (ac) (min) lets) (�) Milt) (in) (in) (R/sec) LENGTH INVERT INVERT ELEVATION PIPE MATEPoAL CB -1 CB -2 0.90 7.27 8813.00 0.20 5.0 Z:11R) 2.5 1.1 Z1 M) Ifty VALUE EMPORARYLINER' PERMANENTLINER'(tt) CB -2 CB -0 0.90 7.27 12012.00 0.28 5.0 1.32 1.32 0.0221 7.1 12 7.3 68.00 391'00 389.50 394 60 CLASS III RCP CB -3 C&4 0.90 7.27 1104600 025 5.0 1.80 3.13 0.0254 96 12 7.8 13800 386.50 383.00 393.17 CLASS III RCP C84 CBE 0.90 7.27 10229.00 0.23 5.0 1.86 1.86 0.0294 7.4 72 84 68.00 385.00 383.00 388.47 CLASS III RCP CB -5 CBE 0.90 7.27 10565.00 0.24 1.54 6.32 0.0424 71.3 15 17.7 178.00 383.00 378.00 387.04 CLASS III RCP CBE CB -8 0.90 7.27 8761.00 0.20 5.0 1.59 1.59 0.0784 8.1 12 6.3 67.00 379.00 378.00 382.33 CLASS III RCP FES -1 DI -7 0.35 727 2857500 068 5.0 1.32 9.23 0.0478 72.8 15 12.5 115.00 378.00 372.50 381.81 CLASS III RCP 0I-7 CB -8 0.90 7.27 1441.00 0.03 5.0 1.67 1.87 0.0185 8.0 12 6.7 27.00 374.00 373.50 CLASS III RCP CB -8 CB -9 0.90 7.27 10493.00 0.24 5.0 0.22 1.89 0.0127 9.0 15 6.4 7900373.50 372.50 376.50" CLASS III RCP CB -9 FES -2 0.90 7.27 9278.00 0.21 5.0 1.58 12.89 0.0202 15.9 78 10.8 6200. 372.50 370.75 376.19 CLASS III RCP 5.0 1.39 14.08 0.0972 'LENGTHS ARE OF THE PIPE ONLY. DOES NOT INCLUDE FLARED END SECTIONS OR OTHER 13.1 18 20.7 1800 . 370.75 369.00 377.07 CLASS III RCP "TOP OF GRATE ELEVATION END TREATMENT. LENGTHS ARE CENTER OF STRUCTURE TO CENTER OF STRUCTURE. SWALE NUMBER 1A 1B 1 C RUNOFF 10 -YEAR COEFFICIENT INTENSITY (iNhr) 0.85 727 0.85 727 0.65 7.27 0.65 1 7.27 1 DRAINAGE AREA (sf) 73505.00 5104.00 9292.00 674.00 DRAIN' -r APl.. (acres) 0.31 0.12 0.21 0.02 lots) 1.47 0.55 1.01 0.07 ( )` 1.47 2.02 3.03 3.10 -ILR INVERT 397.00 391.00 382.50 374.25 LOWER INVERT 391.00 382.50 374.25 374.00 LENGTH IR) 239.00 74.00 101.00 13.00 CRAWFORD TOWNES- PERMANENT SWALE CALCULATIONS CHANNEL BOTTOM FORE BACK CHANNEL CHANNEL SECTION WIDTH SLOPE, SLOPE, DEPTH SLOPE (R) Z:1 (ft) Z:1 (R) (R) (Mft) TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.039 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.081 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.085 TRAPEZOIDAL 1.00 2.50 2.50 1.00 0.013 NORMAL DEPTH (R) 041 0.31 0.38 0.51 FREEBOARD (R) 0.59 0.89 0.82 0.49 SHEAR gTRE33 ((ytt2) 1.00 1.57 2.02 0.41 VELOCITY (APs) 177 3.67 4.09 2.67 MANNING'S n VALUE 0.065 0.040 0040 0.033 TEMPORARY LINER' STRAW WITH NET NAG SC250 NAG SC250 JUTE NET PERMANENTLINER' CLASS C VEGETATION NAG SC250 NAG SC250 CLASS C VEGETATION 2A 0.65 7.27 7202.00 28 0.65 7.27 9168.00 2C 0.65 7.27 3365.00 2D 065 7.27 8032.00 2E 0.65 7.27 1271.00 0.85 7.27 8081.00 2G 0.65 7AS 2337.00 'APPROVED EQUALS ACCEPTED AS ALTERNATES 0.17 0.21 0.08 0.18 0.03 0.19 0.05 078 0.99 0.37 0.87 0.14 0.88 0.25 0.78 1.78 2.14 3.01 3.15 4.03 4.28 398.00 386.00 379.50 374.50 373.50 373.00 371.00 386.00 379.50 374.50 373.50 373.00 371.00 389.00 125.00 119.00 54.00 98.00 18.00 108.00 30.00 TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL TRAPEZOIDAL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.096 0.055 0.093 0.010 0.028 0.019 0.067 0.18 0.32 0.40 047053 0.46 0.57 0.47 0.82 0.88 0.80 0,54 0.43 0.53 1.08 1.09 2.31 0.30 0.80 0.86 1.98 2.99 3.09 3.89 2.94 3.19 2.92 4.19 0.040 0.040 0.040 0.022 0.033 0.033 0.030 NAG SC250 NAG SC250 NAG SC250 JUTE NET STRAW WITH NET STRAW WITH NET NAG SC250 NAG SC250 G SC250 NAG SC250 CLASS VEGETATION CLASS C VEGETATION CLASS C VEGETATION NAG SC250 "DIMENSIONS ARE IRREGULAR AND THUS, NOT LISTED. VOLUME AND SURFACE AREA PER HYDROCAD MODEL "'SKIMMER SIZED PER SIZING CALCULATOR AT VAWVFAIRCLOTHSKIMMER.COM AT A DRAWDOWN RATE OF 72 HOURS CRAWFORD TOWNES -SEDIMENT BASIN SPILLWAY DESIGN BASIN NUMBER Q (cls) CRAWFORD TOWNES -SKIMMER SEDIMENT BASIN DESIGN CALCULATIONS LOWER INVERT LENGTH IR) CHANNEL SECTION BOTTOM WIDTH IRI LEFT SIDE SLOPE, 2:118) SKIMMER SEDIMENT BASIN DESIGN CHANNEL DEPTH lR) CHANNEL SLOPE (fVlt) NORMAL DEPTH (fU FREEBOARD (ft) SHEAR STRESS (16182) VELOCITY IfPsl MANNING'S n VALUE SKIMMER SEDIMENT BASIN EFFICIENCY SK -1 SKIMMER' - 467.00 4(18.00 BASIN DRAINAGE DRAINAGE AREA DISTURBED VOLUME AREA DEPTH VOLUME WIDTH" LENGTH" WEIGHTED REQUIRED SURFACE AREA 0.22 0.78 0.53 NUMBER lac) law lac) CIF (fq (R) (ttl PROVIDED" RAINFALL RAINFALL FLOW Q RUNOFF AREA 325 PROVIDED OPoFlCE RADIUS OPoFlCE LENGTH CHANNEL BOTTOM IA C Im INTENSITY( ) COEFFICIENT SFICFS Total Buoyancy = (1n) (in) DIgMETER Facror of Safety � 1 74 NUMB R (in/hr) lab IsB (acres) (els) INVERT SK -1386 3.86 6,948 2 _ _ 12,526 0.59 7.27 16.56 5,381 7,215 'DEPTH FROM BOTTOM OF SKIMMER BASIN TO SPILLWAY FI FvbnnN Z:11R) 2.5 1.1 Z1 "DIMENSIONS ARE IRREGULAR AND THUS, NOT LISTED. VOLUME AND SURFACE AREA PER HYDROCAD MODEL "'SKIMMER SIZED PER SIZING CALCULATOR AT VAWVFAIRCLOTHSKIMMER.COM AT A DRAWDOWN RATE OF 72 HOURS CRAWFORD TOWNES -SEDIMENT BASIN SPILLWAY DESIGN BASIN NUMBER Q (cls) UPPER INVERT LOWER INVERT LENGTH IR) CHANNEL SECTION BOTTOM WIDTH IRI LEFT SIDE SLOPE, 2:118) PoGHT SIDE SLOPE, Z:1 IRI CHANNEL DEPTH lR) CHANNEL SLOPE (fVlt) NORMAL DEPTH (fU FREEBOARD (ft) SHEAR STRESS (16182) VELOCITY IfPsl MANNING'S n VALUE LINER SK -1 16.58 467.00 4(18.00 26.00 TRAPEZOIDAL 30.00 2.00 2.00 1.00 0.038 0.22 0.78 0.53 2.47 0.040 COEFFlGENT NAG SC250 D Buoyancy Calculations i ADDRESS NCDEO 1/12/2018 FLM COMMENTS Wetland 1 3 ADDRESS FCPU y12I2018 FLM COMMENTS Top of Outlet Structure = 366.00 R CRAWFORD TOWNES - TEMPORARY DIVERSION CALCULATIONS r Bottom = 362.50 R Height of Riser = 3.50 ft TEMPORARY RUNOFF 10 -YEAR DRAINAGE DRAINAGE Q • Development Vbase= 0'x 0'x 0'= 0.00 d Wta 0 d x 15011Vd= 0.00 Ibs V -P= 4'x 4'x 1'= 16.00 d WaumP= 16 d 150 lb/d= 2400.00 Ibs Wstruc = [(5 x 5 x 4H4 x 4 x 3)] x 1501b/d = COEFFlGENT INTENSRY' AREA AREA TOTAL UPPER LOWER LENGTH CHANNEL BOTTOM FORE BACK CHANNEL CHANNELp Total Buoyancy = 5460.00 SHEAR Facror of Safety � 1 74 NUMB R Nhr (i ) I+fl (acres) (els) INVERT INVERT IRI SECTION WIDTH SLOPE, SLOPE, DEPTH SLOPEFREEBOARD STRESSNUMBER VEL�)' Z:11R) Z:1 (R) IRI (RM) M) ((MRZ) VALUE EMPORARYLINER' PERMANENTLINER'(tt) 1 0.35 7.27 82087.00 7.88 4.80 378.00 378.00 229.00 TRAPEZOIDAL 1.00 3.00 3.00 EQUALS ACCEPTED AS ALTERNATES 1.00 0.009042 0.32 3.17 0.022 JUTE NET CLASS C'APPROVED „1---.----- D Buoyancy Calculations i ADDRESS NCDEO 1/12/2018 FLM COMMENTS Wetland 1 3 ADDRESS FCPU y12I2018 FLM COMMENTS Top of Outlet Structure = 366.00 R r Bottom = 362.50 R Height of Riser = 3.50 ft ORIGINAL PLAN SIZE: 24" X 36" ' Assume 6" Wall Thickness ' Weight Calculations CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 • Development Vbase= 0'x 0'x 0'= 0.00 d Wta 0 d x 15011Vd= 0.00 Ibs V -P= 4'x 4'x 1'= 16.00 d WaumP= 16 d 150 lb/d= 2400.00 Ibs Wstruc = [(5 x 5 x 4H4 x 4 x 3)] x 1501b/d = 7125.00 Ibs Total Weight= 9525.00 be Buoyancy Calculations Bbese= 0 d x 62AIbld= 0.00 lbs Batruc = (5 x 5 x 4) x 62.4 INd 5460.00 be Total Buoyancy = 5460.00 be Facror of Safety � 1 74 CALL 48 HOURS BEFORE YOU DIG NORTH CAROLINA ONE -CALL CENTER 1-800-632-4949 ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 REVISION HISTORY RN DESCRIPTION DATE By i ADDRESS NCDEO 1/12/2018 FLM COMMENTS 2 ADDRESS NCDEO 1/23/2018 FLM COMMENTS 3 ADDRESS FCPU y12I2018 FLM COMMENTS ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS W IS 1 INCH IN L -1m W ORIGINAL DRAWING 0 I IF IT IS NOT i INCH -M THIS eNEET,MO YWRSCALE ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 • Development DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 CALCULATIONS C-3 SHEET 3 OF 17 DEVELOPMENT NAME: CRAWFORD TOWNES STREET ADDRESS: NC HWY 56 (E GREEN ST) PIN NUMBER(S): 1865-66-0607 TOTAL AREA: 7.15 AC ZONING DISTRICT: MIXED USE DISTRICT (MUD) SETBACKS FRONT: 25' SIDE: 50' REAR: 50' JURISDICTION: FRANKLINTON PROPOSED USE: TOWNHOMES PROPOSED BUILDING HEIGHT: LESS THAN 30' MINIMUM HORIZONTAL BUILDING SEPARATION: 30 PROPOSED UNITS: 42 PROPOSED DENSITY: 6.1 UNITSIACRE PARKING REQUIRED:2 SPACES FOR EACH DWELLING UNIT PLUS 1 VISITOR SPACE FOR EACH 4 DWELUNG UNITS = 2 X 42 - 4214 = 95 PARKING PROVIDED: 95 (11 VISITOR) MAIL KIOSK PARKING: 2 (1 ADA VAN ACCESSIBLE) WATER SUPPLY WATERSHED: NONE DEVELOPER: CROSSWIND DEVELOPMENT, INC. 7201 CREEDMOOR ROAD, SUITE 147 RALEIGH, NC 27613 FLM ENGINEERING, INC. PO BOX 91727 RALEIGH, NC 27675 919.610.1051 LEGEND NOTES 1. PROPOSED ADA STALLS AND AISLES SHALL HAVE SLOPES NO STEEPER THAN 1'.48 (2%) IN ALL DIRECTIONS. 2. PROPOSED ACCESSIBLE ROUTES SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:20 (5%) AND CROSS SLOPES NO STEEPER THAN 1:48 (2%E 3. THE PRIVATE ROAD SHALL REQUIRE AN NCDOT DRIVEWAY PERMIT AND SHALL BE 26 --WIDE, FACE OF CURB TO FACE OF CURB, W THIN A VARIABLE W DTH ACCESS AND UTILITY EASEMENT. 4. ALL TOWNHOMES SHALL HAVE FRANKLIN COUNTY WATER AND SEWER SERVICE. WATER SHALL BE ACCESSED TO THE NORTH FROM NC HWY 58 (E GREEN ST) AND SEWER SHALL BE ACCESSED TO THE SOUTH FROM THE EXISTING SANITARY SEWER EASEMENT. THE PLANS SHALL BE APPROVED BY FRANKLIN COUNTY, THE MAIN EXTENSIONS APPROVED BY NCDEQ, AND THE RIGHT -OF -WAV ENCROACHMENT APPROVED BY NCDOT. 5. ALL DIMENSIONS ARE TO FACE OF CURB. 6. ALL RADII ARE F UNLESS OTHERW SE NOTED. PROP. 5' SIDEWALK FLUSH TOP OF PROP. MAIL / \ KIOSK PAD PER KIOSK/ INSTALLER SIDEWALK SHALL BE FLUSH AT TRANSITION TO PAVEMENT WITH (1) ZX4' TRUNCATED DOME PANEL AT EACH TRANSITION, \ IT PROP. ADA SIGNAGE WITH VAN ACCESSIBLE SIGN I I II I INSET A SCALE: 1" = 20' SUMMARY AREA (SQ. FT) W WW—V/—(1/ 2,428 1,375 — /vc 1,375 — ---�-- — — \09, 60"ouRm S 1.375 UBL/ GRE ,.375 �I_ — — — - ___.__---- ---- W' �� =` — ` FW�Qy APPROX. LOCATION ENGINEERING 2,831 I I R15' PROP. 10'X 70'SIGHT ` `� IX 16'WATER LINE EX DRIVEWAY TO / -- -:R15' .. ,- (DEPTH UNKNOWN) 2,831 I I BE CLOSED _ TRIANGLE (TVP.) POST OFFICE BOX 91727 1,375 I I ABANDONED EX SANITARY O �---' \ ` \ RALEIGH, NORTH CAROLINA 27675 1,375 I 1 SEWER MANHOLE SANITARY O J / 25' FROM YARD SETBACK 7, w �� PHONE: 919.610.1051 1 1 / -- ` w FIRM NC LICENSE NUMBER C-4222 1,375 / /� / /ROP. VARIABLE: 1,375 1 1 / / /// / / - R5.0000'� - PUBUC ACCESS MENT H DHW 2,831 ( 1 �// / � � R5.0000' / R2W'000 UTILITY EASEMENT \ OH 2,831 I I / EX FENCE AND EDGE OF / K' 1,375 1 1 ASPHALT PAVEMENT \ (y " 1375 1 1/�/ / C2 09 / U IY\� - ,(�Y'(� 1 ///� / n / ON FrT- 1.375 1 // / / \ CJ / CL) I - ''1 1,375 1 (// 2887 5 2,428 I TY / 1,375 / �C6/ / / \ 3� R5.0000' 12 / (2If �¢- PROP. PARKIN SIDEWALK REVISION HISTORY 1,375 TOWN OF FRANKLINTONI / ly 11 ALONG PARKING STALLS / / �J / Q 1,375 ZO' SANITARY SEWER EASEMENT �J q / 16 2,831 I I � � / 101 RaV DESCRIPTION DATE BV 2'831 I I / / / / 30' (TYP.) /�' ADDRESS NCDEO 1,375 I / / R5.0000' / W wF 1 COMMENTS 1/12/2018 FL! 1,375 I / l Q JOHN FOUNDALLIAMTION POPE ADDRESS NCDEQ (2s ly FOUNDATION 2 1/23/2018 FLA 1,375 I l r9 l l l l.� D.B. 2016, PG. 396 COMMENTS 1,375X26 / PB. 7, PG. 57 3 ADDRESS FCPU 2/12/2018 FLA 2,831 I l PIN# 1865-66-3841 COMMENTS 1 I " / 5-o / 2.831 1 1 / / (27 / 1,375 �I / / / 1,375 _ _ _ _ _I— / / (12/ 1IX ,375 / 't --J CONCRETE PAD l / 26 If 29 / 37s PERK/NSON WAY/ I l / R4 �' 14 / / 1 / 3 / / 2,831 40' PUBLIC RIGHT-OF-WAY 1 1 � / / I l 2,831 I WF 14 — FRANKLIN COUNTY / / /19'(TYP.) / 1,375 — — — — -7I DB. 1198, PG. 217 / X13 / / 1 / / 1,375 PB. 2010, PG. 172 / / R5.00W / I / I PIN# 1865-52-9270 1.381----------1--I� / cl ORIGINAL PLAN SIZE: 24" X38" IX SANITARY SEWER I I l lclS MANHOLE(TYP) 1 I / / (3 / — I \\\ PROP. VARIABLE WIDTH \ ,n \ PRIVATE ACCESS AND 35 ' \ V \ UTILITY EASEMENT /\ 1-RS.ODOO'/ / \ \ 5 14 .0000' / (31 I i I Q ISSUED FOR \ \ SEEINSETA,I / / / O \ THIS SHEET Q H \ / R28.0000' / \ WF ( W Z PERMITTING / l JOHN WILLIAM POPE I Vi (D DO NOT USE FOR CONSTRUCTION L \ PROP. 24" CURB l FOUNDATION Q / \ \ 8 GUTTER TVP / l Oil, 2016. PG. 396 ()( PROP. 535 LF 26'-W DE, FACE PIN# 186566-2587 op PROP . I V — — — — — \ DUMPSTER 8 Cl / 37 \ I TO FACE, PRIVATE ROAD IN Q m 40 20 0 40 \ ENCLOSURE \ VARIABLE WDTH ACCESS \ \ (38', AND UTILITY EASEMENT I � 4 SCALE: IINCH = 40 FEET 9B / I N SCALE ADJUSTMENT EX. SANITARY SEWER LINE (TYP) \ \ l \ \ R48.0000' C \ 1HIs sna Is INLN ix LENGTI (SIZE AND MATERIAL UNKNOWM \ ,\B\ il—� \J \\ R5.0000' / 40 i —F— — ON oalclxu DaAwlNc EX STREAM J \ ��� ;/ ,� 1 41 I 7 / I I 11 IF IT Is NOT I WH oN nps \ (TYP)— SHEET, ADJUS YWRSLRLE J RLCORDINGEY PROP. 4' WALK FROM — _ — — _ — — "— — BUILDING TO / V\� \ SIDEWALK I I CONSTRUCTION PLANS PROP. RETAINING / I \ -1 WALL (BV OTHERS) CRAWFORD TOWNES \\\ PROP. STORMWATER I WF l I NC HWY 56 CONTROL MEASURE I II JOHN WILLIAM POPE I FRANKLINTON, NC 27525 FOUNDATION S. 2016, PG. 396 I PR 7, PG. 58-59 P/Np/86Ss6-z472 PROP. 20' PROP .4'TALLBUICK I / I Crosswind FRANKLIN COUNTY \ -. ALUMINUM FENCE TO SANITARY SEWER Com\ \ \ I EASEMENT J SURROUND SCM / Development DATE: 12-07-2017 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM ��`\ \ \ \ PROJECT NO.: 17022 IX. VARIABLE WIDTH \ \ \ � � ' ' � � � pp� WF GREENWAYNTILITY \ V` \ ANDREW W 6 I EASEMENT IN �� \ \ l / KA/TLYNA. TROTTER FRANKLIN COUNTY , \ DB 1198, PG217 D.B. 1975, PG, 943 SITE PLAN . \ _ P.B. 2010, PG. 172 \\\ \\ `� I PIN# 186,5-66-2297 PIN# 1865-52-9270 \\ � ` . I C_4 \` I SHEET 4 OF17 EX. PROPERTY LINE — — EX. RIGHT -OF -WAV — — — — EX. ADJACENT OWNERS ----------- EX. EASEMENT --- --- — EX. ROAD CENTERUNE — — ' — EX. CHANNEUSTREAM — EX. CHANNEUSTREAM BUFFER EX. CHAIN UNK FENCE —DHW—OHW— EX. OVERHEAD ELECTRIC LINE — W — W EX. WATER LINE —SS —SS EX. SANITARY SEWER — SD — SD EX. STORM SEWER ' EX. TREE LINE PROP. LOT LINES ----------- PROP. SETBACK UNE ----------- PROP. EASEMENT NOTES 1. PROPOSED ADA STALLS AND AISLES SHALL HAVE SLOPES NO STEEPER THAN 1'.48 (2%) IN ALL DIRECTIONS. 2. PROPOSED ACCESSIBLE ROUTES SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:20 (5%) AND CROSS SLOPES NO STEEPER THAN 1:48 (2%E 3. THE PRIVATE ROAD SHALL REQUIRE AN NCDOT DRIVEWAY PERMIT AND SHALL BE 26 --WIDE, FACE OF CURB TO FACE OF CURB, W THIN A VARIABLE W DTH ACCESS AND UTILITY EASEMENT. 4. ALL TOWNHOMES SHALL HAVE FRANKLIN COUNTY WATER AND SEWER SERVICE. WATER SHALL BE ACCESSED TO THE NORTH FROM NC HWY 58 (E GREEN ST) AND SEWER SHALL BE ACCESSED TO THE SOUTH FROM THE EXISTING SANITARY SEWER EASEMENT. THE PLANS SHALL BE APPROVED BY FRANKLIN COUNTY, THE MAIN EXTENSIONS APPROVED BY NCDEQ, AND THE RIGHT -OF -WAV ENCROACHMENT APPROVED BY NCDOT. 5. ALL DIMENSIONS ARE TO FACE OF CURB. 6. ALL RADII ARE F UNLESS OTHERW SE NOTED. PROP. 5' SIDEWALK FLUSH TOP OF PROP. MAIL / \ KIOSK PAD PER KIOSK/ INSTALLER SIDEWALK SHALL BE FLUSH AT TRANSITION TO PAVEMENT WITH (1) ZX4' TRUNCATED DOME PANEL AT EACH TRANSITION, \ IT PROP. ADA SIGNAGE WITH VAN ACCESSIBLE SIGN I I II I INSET A SCALE: 1" = 20' SUMMARY AREA (SQ. FT) W WW—V/—(1/ 2,428 1,375 — /vc 1,375 — ---�-- — — \09, 60"ouRm S 1.375 UBL/ GRE ,.375 �I_ — — — - ___.__---- ---- W' �� =` — ` FW�Qy APPROX. LOCATION ENGINEERING 2,831 I I R15' PROP. 10'X 70'SIGHT ` `� IX 16'WATER LINE EX DRIVEWAY TO / -- -:R15' .. ,- (DEPTH UNKNOWN) 2,831 I I BE CLOSED _ TRIANGLE (TVP.) POST OFFICE BOX 91727 1,375 I I ABANDONED EX SANITARY O �---' \ ` \ RALEIGH, NORTH CAROLINA 27675 1,375 I 1 SEWER MANHOLE SANITARY O J / 25' FROM YARD SETBACK 7, w �� PHONE: 919.610.1051 1 1 / -- ` w FIRM NC LICENSE NUMBER C-4222 1,375 / /� / /ROP. VARIABLE: 1,375 1 1 / / /// / / - R5.0000'� - PUBUC ACCESS MENT H DHW 2,831 ( 1 �// / � � R5.0000' / R2W'000 UTILITY EASEMENT \ OH 2,831 I I / EX FENCE AND EDGE OF / K' 1,375 1 1 ASPHALT PAVEMENT \ (y " 1375 1 1/�/ / C2 09 / U IY\� - ,(�Y'(� 1 ///� / n / ON FrT- 1.375 1 // / / \ CJ / CL) I - ''1 1,375 1 (// 2887 5 2,428 I TY / 1,375 / �C6/ / / \ 3� R5.0000' 12 / (2If �¢- PROP. PARKIN SIDEWALK REVISION HISTORY 1,375 TOWN OF FRANKLINTONI / ly 11 ALONG PARKING STALLS / / �J / Q 1,375 ZO' SANITARY SEWER EASEMENT �J q / 16 2,831 I I � � / 101 RaV DESCRIPTION DATE BV 2'831 I I / / / / 30' (TYP.) /�' ADDRESS NCDEO 1,375 I / / R5.0000' / W wF 1 COMMENTS 1/12/2018 FL! 1,375 I / l Q JOHN FOUNDALLIAMTION POPE ADDRESS NCDEQ (2s ly FOUNDATION 2 1/23/2018 FLA 1,375 I l r9 l l l l.� D.B. 2016, PG. 396 COMMENTS 1,375X26 / PB. 7, PG. 57 3 ADDRESS FCPU 2/12/2018 FLA 2,831 I l PIN# 1865-66-3841 COMMENTS 1 I " / 5-o / 2.831 1 1 / / (27 / 1,375 �I / / / 1,375 _ _ _ _ _I— / / (12/ 1IX ,375 / 't --J CONCRETE PAD l / 26 If 29 / 37s PERK/NSON WAY/ I l / R4 �' 14 / / 1 / 3 / / 2,831 40' PUBLIC RIGHT-OF-WAY 1 1 � / / I l 2,831 I WF 14 — FRANKLIN COUNTY / / /19'(TYP.) / 1,375 — — — — -7I DB. 1198, PG. 217 / X13 / / 1 / / 1,375 PB. 2010, PG. 172 / / R5.00W / I / I PIN# 1865-52-9270 1.381----------1--I� / cl ORIGINAL PLAN SIZE: 24" X38" IX SANITARY SEWER I I l lclS MANHOLE(TYP) 1 I / / (3 / — I \\\ PROP. VARIABLE WIDTH \ ,n \ PRIVATE ACCESS AND 35 ' \ V \ UTILITY EASEMENT /\ 1-RS.ODOO'/ / \ \ 5 14 .0000' / (31 I i I Q ISSUED FOR \ \ SEEINSETA,I / / / O \ THIS SHEET Q H \ / R28.0000' / \ WF ( W Z PERMITTING / l JOHN WILLIAM POPE I Vi (D DO NOT USE FOR CONSTRUCTION L \ PROP. 24" CURB l FOUNDATION Q / \ \ 8 GUTTER TVP / l Oil, 2016. PG. 396 ()( PROP. 535 LF 26'-W DE, FACE PIN# 186566-2587 op PROP . I V — — — — — \ DUMPSTER 8 Cl / 37 \ I TO FACE, PRIVATE ROAD IN Q m 40 20 0 40 \ ENCLOSURE \ VARIABLE WDTH ACCESS \ \ (38', AND UTILITY EASEMENT I � 4 SCALE: IINCH = 40 FEET 9B / I N SCALE ADJUSTMENT EX. SANITARY SEWER LINE (TYP) \ \ l \ \ R48.0000' C \ 1HIs sna Is INLN ix LENGTI (SIZE AND MATERIAL UNKNOWM \ ,\B\ il—� \J \\ R5.0000' / 40 i —F— — ON oalclxu DaAwlNc EX STREAM J \ ��� ;/ ,� 1 41 I 7 / I I 11 IF IT Is NOT I WH oN nps \ (TYP)— SHEET, ADJUS YWRSLRLE J RLCORDINGEY PROP. 4' WALK FROM — _ — — _ — — "— — BUILDING TO / V\� \ SIDEWALK I I CONSTRUCTION PLANS PROP. RETAINING / I \ -1 WALL (BV OTHERS) CRAWFORD TOWNES \\\ PROP. STORMWATER I WF l I NC HWY 56 CONTROL MEASURE I II JOHN WILLIAM POPE I FRANKLINTON, NC 27525 FOUNDATION S. 2016, PG. 396 I PR 7, PG. 58-59 P/Np/86Ss6-z472 PROP. 20' PROP .4'TALLBUICK I / I Crosswind FRANKLIN COUNTY \ -. ALUMINUM FENCE TO SANITARY SEWER Com\ \ \ I EASEMENT J SURROUND SCM / Development DATE: 12-07-2017 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM ��`\ \ \ \ PROJECT NO.: 17022 IX. VARIABLE WIDTH \ \ \ � � ' ' � � � pp� WF GREENWAYNTILITY \ V` \ ANDREW W 6 I EASEMENT IN �� \ \ l / KA/TLYNA. TROTTER FRANKLIN COUNTY , \ DB 1198, PG217 D.B. 1975, PG, 943 SITE PLAN . \ _ P.B. 2010, PG. 172 \\\ \\ `� I PIN# 186,5-66-2297 PIN# 1865-52-9270 \\ � ` . I C_4 \` I SHEET 4 OF17 LEGEND WATER MAIN CONSTRUCTION NOTES -- -4 I —N W PROP. B" x 8' MJ TEE \i (2) PROP. 8" MJ GATE VALVES_ PROP. 8"-90' MJ BEND AND BOXES _ 1 PROP. 8" x 8' MJ TEE PROP. MASTER (2) PROP. 8" MJ GATE VALVES METER BY-PASS — I-- -�--- BACKSIDE TAP SHOWN, BUT IS SUBJECT TO CHANGE BASED ON FIELD CONDITIONS AND LOCATION OF _ EXISTING WATERLINE. 50 LF OF 18" STEEL CASING PIPE TO EXTEND MIN. 5' BEYOND EX. EDGE OF PAVEMENT (CROSS UNDER EXISTING 16' MAIN) AND BOXES ( RJ DIP) —PROP. VARIABLE WIDTH EX DRIVEWAY TO / PUBLIC ACCESS ANDS I BE CLOSED UTILITY EASEMENT PROP. 8" - 90° MJ BEND PROP. 8" x 8' MJ REDUCER I I ABANDONED EX SANITARY C� 25' FRONT y (WATERLINE TO TRANSIT ION 1 SEWER MANHOLE (TYP) OO - /—�OSETBACK r TO 6' 0900 DR18 PV) I 1 1 / ' PROP. GRAVITY SEWER MANHOLE (TY % ) FOLLOWING REDUCER I I IF EX FENCE AND EDGE OF l MASTER METER BYPASS I 1 ��ASPHALT PAVEMENT l LAYOUT 1 �/ 1. ALL WATER DISTRIBUTION CONSTRUCTION TO BE IN ACCORDANCE WITH FRANKLIN COUNTY PUBLIC UTILITIES STANDARDS AND SPECIFICATIONS FOR WATER AND SEWER. 2, CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLIN COUNTY PUBLIC UTIUTIES. 3. EXISTING MAINS ARE SHOWN TO THE EXTENT POSSIBLE AND ARE GENERALLY NOTED "APPROXIMATE LOCATION, DEPTH UNKNOWN". IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ACCURATELY LOCATE EXISTING FACILITIES BY DIGGING A TEST PIT TO VERIFY EXISTING MAIN LOCATION, SIZE, DEPTH, AND MATERIAL. 4. THE CONTRACTOR SHALL OBTAIN A UTILITY LOCATION FOR ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. THE LOCATION OF KNOWN UTILITIES IS SHOWN ON THE PLAN TO THE EXTENT POSSIBLE. ALL DISCREPANCIES SHALL BE NOTED AND DISCUSSED WITH THE ENGINEER PRIOR TO CONSTRUCTION. 5. THE CONTRACTOR SHALL NOTIFY FRANKLIN COUNTY PUBLIC UTILITIES PRIOR TO TAPPING ANY MAIN, TURNING ANY EXISTING VALVES, OR BEGINNING CONSTRUCTION ON ANY SEGMENT OF THE PROJECT. A CURRENT COPY OF THE APPROVED DESIGN PLANS, ENCROACHMENT AGREEMENTS, AND SPECIFICATIONS OF THE UTILITY SHALL BE MAINTAINED ON SITE AT ALL TIMES. 6. MAIN LOCATIONS, VALVE LOCATIONS, HYDRANT LOCATIONS, AND SERVICE LOCATIONS ARE SHOWN FOR ILLUSTRATIVE PURPOSES. REFER TO STANDARD DETAILS FOR PRECISE LOCATION OF THESE ITEMS. HYDRANTS SHALL BE LOCATED WITHIN 10' UTILITY EASEMENT. VALVES LOCATED WITHIN NCDOT RIGHT OF WAV SHALL BE INSTALLED IN ACCORDANCE WITH NCDOT STANDARDS. VALVE MARKERS AND VENTS SHOULD BE INSTALLED AT THE RIGHT OF WAY LINE. VALVES SHALL NOT BE LOCATED WITHIN PAVEMENT TO THE EXTENT PRACTICAL OR WITHIN THE LIMITS OF THE FRONT SLOPE OR BOTTOM OF THE DITCH. 7. MINIMUM DEPTH OF BURY FOR WATER MAINS SHALL BE 4'. 8. WATER SERVICE STUB -OUTS SHALL BE MADE PRIOR TO PLACEMENT OF ROADWAY STONE. 9, TRACER WIRE SHALL NOT BE INSTALLED INSIDE GATE VALVE BOXES. CONTRACTOR SHALL INSTALL WIRES IN A 4' PVC PIPE CLEANOUT AT MAIN VALVES WITH A BRASS CAP AND CONCRETE DONUT. SANITARY SEWER CONSTRUCTION NOTES 1. ALL SANITARY SEWER CONSTRUCTION TO BE IN ACCORDANCE WITH FRANKLIN COUNTY PUBLIC UTILITIES STANDARDS AND SPECIFICATIONS FOR WATER AND SEWER. 2, CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLIN COUNTY PUBLIC UTILITIES. 3. MINIMUM DEPTH OF COVER FOR GRAVITY SEWERS SHALL BE 4'. 4. GRAVITY SEWER WITHIN 50 OF SURFACE WATERS OR WETLANDS SHALL BE DUCTILE IRON PIPE AND HAVE MATERIALS, TESTING METHODS AND ACCEPTABILITY STANDARDS MEETING WATER MAIN STANDARDS (15A NCAC 18C), 5. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND SANITARY SEWER SHALL BE 10 FEET. WIZEN RUNNING PARALLEL, THE TOP OF SANITARY PIPING SHALL BE AT LEAST 18 INCHES BELOW THE BOTTOM OF THE WATER MAIN. WHEN CROSSING, THE TOP OF SANITARY PIPING SHALL BE AT LEAST 24 INCHES BELOW THE BOTTOM OF THE WATER MAIN. 6, MINIMUM SEPARATION BETWEEN SANITARY SEWER AND STORM DRAINAGE IS 24 INCHES. 7. MINIMUM SEPARATION BETWEEN WATER AND STORM DRAINAGE IS 18 INCHES. 8. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER 8 SEWER FACILITIES WITH 18" MINIMUM VERTICAL SEPARATION. 9. MAXIMUM MANHOLE SPACING SHALL BE 400'. 10. GRAVITY SEWER MANHOLES TO HAVE WATERTIGHT MANHOLE RING AND COVERS. NOTES 1. ALL TOWNHOMES WITHIN 500' RADIUS OF EITHER EXISTING OR PROPOSED FIRE HYDRANTS. 2. ALL WATER AND SEWER UTILITIES LOCATED WITHIN PUBLIC EASEMENTS TO BE MAINTAINED BY FRANKLIN COUNTY PUBLIC UTILITIES. ALL OTHER WATER AND SEWER UTILITIES TO BE PRIVATE AND MAINTAINED BY PRIVATE ENTITY. O EOR IN PMT Wff11WT WRITTEN PERMLSSgN OF Fl -M ENGINEERING. NC. / EX. PROPERTY LINE / — — EX. RIGHT -OF -WAV 1 — — — EX. ADJACENT OWNERS r ----------- EX. EASEMENT — EX. ROAD CENTERUNE / — — — EX. CHANNEUSTREAM 1 — EX. CHANNEUSTREAM BUFFER( ADDRESS FCPU rnuuc y12/2018 EX. CHAIN LINK FENCE ` — OHW— OHW— EX. OVERHEAD ELECTRIC LINE — W — W EX. WATERLINE — SS —SS EX. SANITARY SEWER / SD — SD EX. STORM SEWER 1\ PROP. CLEANOUT FO) I SEWER SERVICE (TVPYP/ 2 / / EX. TREE LINE r DB 1198, PG. 217 / PROP. LOT LINES l/\ — -- --- PROP. SETBACK UNE r ----------- PROP. EASEMENT 1\ — W — W PROP. WATER LINE —551 —SS PROP. SANITARY SEWER 17 (y� 1 PROP. STORM SEWER ❑ PROP. WATER METER D4 PROP. GATE VALVE PROP. FIRE HYDRANT ASSEMBLY WITH GATE VALVE AND TEE O PROP. SEWER CLEANOUT WATER MAIN CONSTRUCTION NOTES -- -4 I —N W PROP. B" x 8' MJ TEE \i (2) PROP. 8" MJ GATE VALVES_ PROP. 8"-90' MJ BEND AND BOXES _ 1 PROP. 8" x 8' MJ TEE PROP. MASTER (2) PROP. 8" MJ GATE VALVES METER BY-PASS — I-- -�--- BACKSIDE TAP SHOWN, BUT IS SUBJECT TO CHANGE BASED ON FIELD CONDITIONS AND LOCATION OF _ EXISTING WATERLINE. 50 LF OF 18" STEEL CASING PIPE TO EXTEND MIN. 5' BEYOND EX. EDGE OF PAVEMENT (CROSS UNDER EXISTING 16' MAIN) AND BOXES ( RJ DIP) —PROP. VARIABLE WIDTH EX DRIVEWAY TO / PUBLIC ACCESS ANDS I BE CLOSED UTILITY EASEMENT PROP. 8" - 90° MJ BEND PROP. 8" x 8' MJ REDUCER I I ABANDONED EX SANITARY C� 25' FRONT y (WATERLINE TO TRANSIT ION 1 SEWER MANHOLE (TYP) OO - /—�OSETBACK r TO 6' 0900 DR18 PV) I 1 1 / ' PROP. GRAVITY SEWER MANHOLE (TY % ) FOLLOWING REDUCER I I IF EX FENCE AND EDGE OF l MASTER METER BYPASS I 1 ��ASPHALT PAVEMENT l LAYOUT 1 �/ 1. ALL WATER DISTRIBUTION CONSTRUCTION TO BE IN ACCORDANCE WITH FRANKLIN COUNTY PUBLIC UTILITIES STANDARDS AND SPECIFICATIONS FOR WATER AND SEWER. 2, CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLIN COUNTY PUBLIC UTIUTIES. 3. EXISTING MAINS ARE SHOWN TO THE EXTENT POSSIBLE AND ARE GENERALLY NOTED "APPROXIMATE LOCATION, DEPTH UNKNOWN". IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ACCURATELY LOCATE EXISTING FACILITIES BY DIGGING A TEST PIT TO VERIFY EXISTING MAIN LOCATION, SIZE, DEPTH, AND MATERIAL. 4. THE CONTRACTOR SHALL OBTAIN A UTILITY LOCATION FOR ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. THE LOCATION OF KNOWN UTILITIES IS SHOWN ON THE PLAN TO THE EXTENT POSSIBLE. ALL DISCREPANCIES SHALL BE NOTED AND DISCUSSED WITH THE ENGINEER PRIOR TO CONSTRUCTION. 5. THE CONTRACTOR SHALL NOTIFY FRANKLIN COUNTY PUBLIC UTILITIES PRIOR TO TAPPING ANY MAIN, TURNING ANY EXISTING VALVES, OR BEGINNING CONSTRUCTION ON ANY SEGMENT OF THE PROJECT. A CURRENT COPY OF THE APPROVED DESIGN PLANS, ENCROACHMENT AGREEMENTS, AND SPECIFICATIONS OF THE UTILITY SHALL BE MAINTAINED ON SITE AT ALL TIMES. 6. MAIN LOCATIONS, VALVE LOCATIONS, HYDRANT LOCATIONS, AND SERVICE LOCATIONS ARE SHOWN FOR ILLUSTRATIVE PURPOSES. REFER TO STANDARD DETAILS FOR PRECISE LOCATION OF THESE ITEMS. HYDRANTS SHALL BE LOCATED WITHIN 10' UTILITY EASEMENT. VALVES LOCATED WITHIN NCDOT RIGHT OF WAV SHALL BE INSTALLED IN ACCORDANCE WITH NCDOT STANDARDS. VALVE MARKERS AND VENTS SHOULD BE INSTALLED AT THE RIGHT OF WAY LINE. VALVES SHALL NOT BE LOCATED WITHIN PAVEMENT TO THE EXTENT PRACTICAL OR WITHIN THE LIMITS OF THE FRONT SLOPE OR BOTTOM OF THE DITCH. 7. MINIMUM DEPTH OF BURY FOR WATER MAINS SHALL BE 4'. 8. WATER SERVICE STUB -OUTS SHALL BE MADE PRIOR TO PLACEMENT OF ROADWAY STONE. 9, TRACER WIRE SHALL NOT BE INSTALLED INSIDE GATE VALVE BOXES. CONTRACTOR SHALL INSTALL WIRES IN A 4' PVC PIPE CLEANOUT AT MAIN VALVES WITH A BRASS CAP AND CONCRETE DONUT. SANITARY SEWER CONSTRUCTION NOTES 1. ALL SANITARY SEWER CONSTRUCTION TO BE IN ACCORDANCE WITH FRANKLIN COUNTY PUBLIC UTILITIES STANDARDS AND SPECIFICATIONS FOR WATER AND SEWER. 2, CONSTRUCTION MATERIALS SHALL BE AS SPECIFIED BY FRANKLIN COUNTY PUBLIC UTILITIES. 3. MINIMUM DEPTH OF COVER FOR GRAVITY SEWERS SHALL BE 4'. 4. GRAVITY SEWER WITHIN 50 OF SURFACE WATERS OR WETLANDS SHALL BE DUCTILE IRON PIPE AND HAVE MATERIALS, TESTING METHODS AND ACCEPTABILITY STANDARDS MEETING WATER MAIN STANDARDS (15A NCAC 18C), 5. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND SANITARY SEWER SHALL BE 10 FEET. WIZEN RUNNING PARALLEL, THE TOP OF SANITARY PIPING SHALL BE AT LEAST 18 INCHES BELOW THE BOTTOM OF THE WATER MAIN. WHEN CROSSING, THE TOP OF SANITARY PIPING SHALL BE AT LEAST 24 INCHES BELOW THE BOTTOM OF THE WATER MAIN. 6, MINIMUM SEPARATION BETWEEN SANITARY SEWER AND STORM DRAINAGE IS 24 INCHES. 7. MINIMUM SEPARATION BETWEEN WATER AND STORM DRAINAGE IS 18 INCHES. 8. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER 8 SEWER FACILITIES WITH 18" MINIMUM VERTICAL SEPARATION. 9. MAXIMUM MANHOLE SPACING SHALL BE 400'. 10. GRAVITY SEWER MANHOLES TO HAVE WATERTIGHT MANHOLE RING AND COVERS. NOTES 1. ALL TOWNHOMES WITHIN 500' RADIUS OF EITHER EXISTING OR PROPOSED FIRE HYDRANTS. 2. ALL WATER AND SEWER UTILITIES LOCATED WITHIN PUBLIC EASEMENTS TO BE MAINTAINED BY FRANKLIN COUNTY PUBLIC UTILITIES. ALL OTHER WATER AND SEWER UTILITIES TO BE PRIVATE AND MAINTAINED BY PRIVATE ENTITY. O EOR IN PMT Wff11WT WRITTEN PERMLSSgN OF Fl -M ENGINEERING. NC. / REV 3 4 PROP 20 / 1 FRANKLIN COUNTY / I U/ TOWN OF FRANKL/NTON I I 20. SAN/TARY SEWER 1r�� 'I l / ATER �/ PROP. 5/8"W / Q1y� SERVICE METER (TVP.) EAIf SEMENT I ADDRESS NCDEO / cr, / i? I 3 ADDRESS FCPU rnuuc y12/2018 ��__ EASEMENT \ \ REAR yARO t\ PROP. SERVICE I I PERKINSON WAY I j EX CONCRETE PAD l l / 40' PUBLIC RIGHT-OF-WAY � l / / / /J F FRANKLIN COUNTY / PROP. CLEANOUT FO) I SEWER SERVICE (TVPYP/ 2 / / I DB 1198, PG. 217 / 3 I / I / P B. 2010, PG. 172 / P/N# 1 &&552-9270 / I EX. SANITARY SEWER I I l MANHOLE(TYP) I l\ l / 6 l ( / \\ / 17 (y� 1 \ — ,n\ \\ PROP. VARIABLE/ WIDDTH PRIVATE ACCESSANUTILITV EASEMENT\�\ / 18 iX / MANHOLE \ I / Top= ��i�l/ \\ `�1 \ F (1) PROP. 8" RJ 90' BEND 8 (1) PROP. " RJ 9W BEND (ANGLED UPWARDS AT 45°) �— (1) PROP. 16' x W MJ TAPPING SLEEVE (1) PROP. F. MJ TAPPING GATE VALVE AND BOX PIPE TO BE 8" CL350 DUCTILE IRON WATERLINE NC / -/WY -CROSSING UNDER 60%,U56 SROAD VIA BORE & JACK. ��^� BS/C RG GREEN I Sly •/ APPROX LOCATION EX 16 -WATER IIIVE PROP. 8" MASTER METER 8 PRECAST CONCRETE \ W \ (DEPTH UNKNOWN) µ' VALVE VAULT WITH BYPASS (SEE INSET, THIS SHEET) PROP.µ' 8" BACK FLOW PREVENTER - IY \ \ IN ABOVE GROUND "HOT BOX' ��-- - \W _ PROP. 8" x 6' REDUCER AND TRANSITION \ TO 6'C900 DR18 PVC WATERLINE �\ \ I1µ, 3 \ ,0 �\ \ / 20 / / 23 -I / 24 \7/ / 0 PROP. STORM DRAINAGE / INLET GRATE (TYP.)WF I lQ JOHN WILL AM POPE l l y FOUNDATION l,R D. 8.2016 G.396 l P.8 7, PG. 57 / P/N# 1865653841 / 27 28 If 30 29 If PROP. 6" C900 DR -18 PVC WATER LINE / 31 33 34 / I I PROP. PRIVATE 6" SDR35 GRAVITY SEWER \ 1 JOHN WILLIAM POPE I W = SEE SHEET C-10 FOR PLAN AND PROFILES) I Q o Q O FOUNDATION \ \ B. 2016 PG. 396 Q PIN# 18x56525&7 � U EX SANITARY SEWER LINE (rvP) (SIZE AND MATERIAL UNKNOWN) \\ V \ \\\ y ? 39 I / / \ \ PROP. PUBLIC B' SDR35 GRAVITY SEWER — J (SEE SHEET C-10 FOR PLAN AND \ 42 I -- — I PROFILES) // / I .— —. � � — -- ) PROP. 6'22.5°MJ BEND If `I1 \ / PROP. HYDRANT` / 1" WF ` ASS'V \ 1 `I JOHN WILLIAM POPE ``\ / \ 1 / I FOUNDATION I I PROP.OLMEA URETER I D.B. 2016, PG. 396 \\\ \\\ I / / CONTROL MEASURE / ) PB 7, PG. 5&59 PIN# 1855-66-2472 ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER 04222 3`_ REVISION HISTORY REV AS SHOWN PROP 20 / 1 FRANKLIN COUNTY / DESCRIPTION DATE BY 1 ��Iggg999777ppppDD''3g ]]]'''------ i PROJECT NO.: 1/12/2018HFLM SANITARY SEWER ADDRESS NCDEO I 3 ADDRESS FCPU rnuuc y12/2018 ��__ EASEMENT \ \ REAR yARO t\ PROP. SERVICE 5/8"WATER METER(TYP) / i / (\\\ \ I PROP. I- UTILITY EASEMENT EX SANITARY SEWER— `� MANHOLE \ I / Top= ��i�l/ \\ `�1 \ PROP. CLEANOUT FOR 4" SEWER SERVICE (TVP.) INV /N = 362.52' \ 362.52. = \ \ i EK. VARIABLE WIDTH INV OUT362.23' \ \ GREENWAYNT/LITY � � � \ \\ � ' — � / WF W W W —� (y _ EASEMENT JP \ \ \\ ANDREW W. 6 WF `1 KAITLYNA. T ROTTER FRANKLIN COUNTY v`\ O.B. 1198, PG. 217 \ \ EX STREAM OB. 1975, PG. 943 P.B. 7, PG, 5&-59 _ PB 2010, PG. 172 \ \ (TYP.) PIN# 1865 52-92 70 \\ �` \ I MAIN 186566-2297 $ SS TYPICAL WATER AND SEWER SERVICE LAYOUT ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER 04222 3`_ REVISION HISTORY REV AS SHOWN # DESCRIPTION DATE BY 1 ADCDRESS NCDEOOMMENTS PROJECT NO.: 1/12/2018HFLM 2 ADDRESS NCDEO COMMENTS 1/23/2018 3 ADDRESS FCPU rnuuc y12/2018 ORIGINAL PLAN SIZE: 24" X 36 - ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 40 20 0 40 SCALE: 1 INCH = 40 FEET SCALE ADJUSTMENT THIS MR IS 1 INCH IN LENGTN ON ORIGINAL ORHWING 1 IF IT IS NOT 11NCH ON THIS —ET.AD— YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 W�Crosswind evelopment DATE: 12-07-2017 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 UTILITY PLAN C-5 SHEET 5 OF 17 LEGEND �N VV W W -- EX. PROPERTY LINE FFE SUMMARY W W dhrannY EX. RIGHT -OF -WAV LOT N0. FFE ELEV. 397. . J - - - - EX. ADJACENT OWNERS 39900 - ----------- EX. EASEMENT 398.00- - ----- EX. ROAD CENTERUNE -t392 ,7g5. �O EX. CHANNEUSTREAM - r -I - - - - EX. CHANNEUSTREAM BUFFER I I EX DRIVEWAYTO / EX. CHAIN LINK FENCE I I BE CLOSED 7 ( I ABANDONED EX SANITARY - OHW- (lHW- EX. OVERHEAD ELECTRIC LINE ( ( SEWER MANHOLE (TYP.) S l W - W EX. WATER LINE 8 ( ( i' BEGIN PROP. SS -SS EX. SANITARY SEWER 9 391.00 i (( / 1 PERMANENT SWALE#1A - SD - SD EX. STORM SEWER 10 390.00 EX. TREE LINE 11 390.00 I ( \ ( PROP. LOT LINES 12 387'00 EX FENCE AND EDGE OF ( ( �i� /moi ASPHALTPAVEMENT - - - - ------ PROP. SETBACK LINE 13 387.00 ( (� - - - - - - - - - - PROP. EASEMENT 14 366.00 325 PROP. MAJOR CONTOUR (5') 15 385.00 324 PROP. MINOR CONTOUR(,') 16 384.00 I W W - PROP. WATER LINE 17 384.00 I Y SS -SS - PROP. SANITARY SEWER 18 363.00 PROP. STORM SEWER 19 399.00 PROP. CURB INLET 20 398.00 PROP. FLARED END SECTION 21 398.00 TOWN OF FRANKLINTON LD -LD PROP. LIMIT OF DISTURBANCE 22 397.00 20 SANITARYSEWER 23 397.00 EASEMENT 24 398.00 25 394.00 26 393.00 1 / FRANKLIN COUNTY ) NOTES n 392.001 D.B. 1198, PG 217 1 /P B. 2010. PG 172 1. SEE SHEET C 3 FOR STORMWATER DRAINAGE CALCULATIONS. 28 391.00 I / PIN# 1865-52-9270 o 29 391.00 2. PROPOSED CONTOURS SHOWN REPRESENT FINISH GRADES. 30 390.00 3. PROPOSED ADA STALLS AND AISLES SHALL HAVE SLOPES NO 31 388.00 / I / BEGIN PROP. STEEPER THAN 1:48 (2%) IN ALL DIRECTIONS. 32 387.00 I ' / PERMANENT SWALE #1B 4. CUT AND FILL SLOPE SHALL BE 3111V UNLESS OTHERWISE NOTED. 33 386.00 / PERK/NSON WAY 5. RETAINING WALLS SHOWN ARE BY OTHERS. 34 385.00 ¢0' PUBLIC 35 385.00I l / 385' RIGHT-OF-WAY -� 1 m 6. STORMWATER CONTROL MEASURES SHALL BE PRIVATE AND 36 384.00 I EX CONCRETE PAD � MAINTAINED BY THE HOME OWNERS ASSOCIATION. 37 382.00 38 381.00 I BEGIN PROP / 6 -F - PERMANENT SWALE#)1C PROP. 5' SIDEWALK 40 379.00 1 I L/ / FLUSH TOP OF PR P. MAIL � SK TC CURB PkD PER KIOSK •378.50 42 370.00 I I 380' INSTALLER\ / IX_ SANITARY 1 / PROP. VARIABLE WIDTH 0 SEWER MANHOLE I ' \ / BC (Typ) I ( / PRIVATE ACCESS AND 378.00 ( \ UTILITY EASEMENT SPOT \ / 4 376.50 \ C\ / \\ BEGIN PROP. I C8 ' 37790' \ • PERMANENT SWALE#1D� / SIDEWALK SHALL BE 4(/� BC \ / �� \\ (� ! V ~( FLUSH AT TRANSITION \ \ TO PAVEMENT WITH (1) 1 TC TC�v 377.80 \\ \ \\ \ ��c-� /SEE INSET B. 2'X4' TRUNCATED 378.40 BC \ / \ "'� THIS SHEET DOME PANTRA T EACH ,SPOT 1 78, 78615 377.65 -,3111 I 378.15 / \ \\AX \ ` PROP. 24" CURB \ \ 37p• l 8 GUTTER \ SPOT 377.75 (TVP.) 375 / \\ \\ fill �� 375 EX SANITARY SEWER LINE (TYP) INSET (SIZE AND MATERIAL UNKNOWN) \ SCALE: 1" 20' / `•\�.� CB -9 \ \ l 50'TAPJPAMLICO / \\ RIVE RBUFFER FROM tPB,/ \ TOP OF BANK(TYP) - / E � \ / EX. STREAM R z4g, / 380, `S'-`„���,\ �- vv 3� PRC FRA SAN C % 395! ` LJ 9 i /r 390' - /W l 9 I 385 /I BEGIN PROP WF ' PERMANENT SWALE #213 JOHN WPOPE l i FOUNDATION / O.B. 2016, PG. 398 l PB 7, PG. 57 380 PIN#1865%3841 / A"I i 375 I /BEGIN PROP. / „e PERMANENT SWALE #2C / BEGIN PROP. J /PERMANENT SWALE #2D WF I BEGIN PROP. JOHN WILLIAM POPE I Q PERMANENT SWALE #2E FOUNDATION \\ \ D.B. 2016, PG. 396 I o. PIN# 1865.662587 V 313 I a BEGIN PROP. \J I PERMANENT SWALE #2F �. I /I I / ( l \ � 365 `I BEGIN PROP. PERMANENT SWALE #2 I /T I � I � i _ l i I ( / I I I I I I IIF ANDREW W B K41TLYN A. TROTTER I I D B. 1975. PG. 943 I PB. 7, PG. 56-59 PIN# IWS-662297 I I I I ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C4222 '7, � REVISION HISTORY REV EX VARIASLEWIDTH # DESCRIPTION DATE GREENWAY/UTILITY W 1 AODRESSNCDEO EASEMENT FRANK UN COUNTY COMMENTS 1/12/2018 D.B. 1196, PG. 217 2 ADDRESS NCDEO P B. 2010. PG. 172 COMMENTS 1/23/2018 PIN# 1865-52-9270 ADDRESS FCPU \ COMMENTS y12/2018 FLM I I I I I IIF ANDREW W B K41TLYN A. TROTTER I I D B. 1975. PG. 943 I PB. 7, PG. 56-59 PIN# IWS-662297 I I I I ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C4222 '7, � REVISION HISTORY REV # DESCRIPTION DATE BY 1 AODRESSNCDEO COMMENTS 1/12/2018 FLM 2 ADDRESS NCDEO COMMENTS 1/23/2018 FLM ADDRESS FCPU 3 COMMENTS y12/2018 FLM ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 40 20 0 40 SCALE. 1 INCH = 40 FEET N SCALE ADJUSTMENT -11 BAR IS 1 1-1IN LENGTH ON OR- DR NG 4 ,• L I IF IT R NOT , INCH ON THIS SNEU. AO.IIIST YWR SCALE ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 romwind6pt,el.opment DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 GRADING AND DRAINAGE PLAN C-6 SHEET 6 OF 17 LEGEND EX. PROPERTY LINE -W--- -- - - WW W W - - E%. RIGHT -OF -WAV � EX. ADJACENT OWNERS -we+�....r,...,.....W.,w.. ----- ----- EX. EASEMENT - - --- -\ off Oi 60HIyySB E EX. ROAD CENTERU NE _ �,,� -- EX. CHANNEUSTREAM - W- �"- ��_�_BL/C R G GREEN S ENGINEERING - 7-I EX. CHANNEUSTREAM BUFFER LINKAte' 385• - ` \ `` \�F- '/ ao1`..\` \ \\ �wAY APPROX. LOCATION EX. CHAIN NK FENCE - _... - I I EX DRIVEWAY TO (DEPTH UNKNOWN) - OHW- OHW- EX. OVERHEAD ELECTRIC LINE +r(4# w.el.r+I..nNg4r w rA I I BE CLOSED \ 1 POST OFFICE BOX 91727 W - W EX. WATER LINE - ---- _-. _ i 1 ABANDONED EX SANITARY lr RALEIGH, NORTH CAROLINA 27675 -SS -SS EX. SANITARY SEWER wM.rrr. rMI. + - r..rrw SEWER MANHOLE �- / �- -J--- _-- PHONE 919.610.1051 '. uwN rwF 1 1 LE \\ FIRM NC LICENSE NUMBER C-4222 SD - SD EX. STORM SEWER .- - '-- - - --.._- ..... I I / �i n i�Ifi ;a. Irrr wr• 1 EX. TREE LINE ��/ � / PROP. / 25-FRONTYARD DATBACK W w, PROP. LOT LINES � � 1 ® .....+rArw... wrrlNr.rlrr. I I �� �� \ / / CONCRETE / � ETBACK`39�. � I I i FENCE AND EDGE OF / WASHOUT PIT / OHw- -- --- PROP. SETBACK UNE ice/ PHALTPAVEMENT l l O �� ' _ I 1 �� ! ---------- PROP. EASEMENT 1 \ H - l w\ ONw� 325 PROP . MAJOR CONTOUR (5') 1 �� PROP. 24x 100'TEMPORARY / \ `, •,'• I _ / _ _ 395 rr„ 324 - PROP. MINOR CONTOUR (1') CONSTRUCTION ENTRANCE I> S ------ W - W PROP. WATER LINE / r/ w y%"/ y00p333/ PROP. SANITARY SEWER ! / / �/ / - /'ggg7 1 .:: PROP. STORM SEWER ! ! ' I' � y '. / / %7y • •!1lr. • -�: / ! U - PROP. LIMITS OF STAGING ' � /"•. CHASE �.```�,, PROP. CURB INLET ! \ /me STOCKPILE, AND/OR CONCRETE /'-' 390' - "... .•" PROP. FLARED END SECTION ! \ WASHOUT AREA LOCATED 50' ! /i FROM STORM DRAINS AND ! ! //!,Q $ / - LD - LD - PROP. LIMIT OF DISTURBANCE TOWN OF FRANKL/NTON ! ! Q SURFACE WATERS ! y\ >> TO >>- PROP. TEMPORARY DIVERSION DITCH 20' SANITARY SEWERJ ! - REVISION HISTORY 1�J l �hW / / /W / REV _SF -SF c EASEMENT PROP. SILT FENCE I � p 385' # DESCRIPTION DATE BY -%-x-7L-It-%-x-%-x- PROP. BAFFLE ! ! / /'x \ --0 PROP. FAIRCLOTH SKIMMER! / \• �b /aQ / / 1 ADCOMMENTS NCDWF 1/122018EO FU ! / JOHN WILLIAM POPEl ® PROP. SLOPE PROTECTION ! l yFOUNDATION 2 ADDRESS NCDEQ PROP. CONSTRUCTION ENTRANCE ! / \� ,5a� ! y D.8. 2016, PG. 396 / COMMENTS 1/23/2018 FLA ! / B 7 PG. 57 ADDRESS FCPU PROP. HORSESHOE INLET PROTECTION/P. CHECK DAM ! / S // / .n / �..-- 380• p/Np 1865.86-3841 / 3 COMMENTS y12/2018 FLA ® PROP. SILT FENCE OUTLET ! ! / / / 0 PROP. INLET PROTECTION EROSION CONTROL NOTES / / !- I •/ \/_ / / / PRO(TYP. SILT FENCE / -~J EX CONCRETE PAD l /, X , 1 / 1. ALL LAND DISTURBING ACTIVITIES SHALL BE CONDUCTED IN ACCORDANCE WTH NCDEQ PERK/NSON WAY ! ! l /I PROP. CHECK DAM/ / STANDARDS. (IVP) / 40' PUBLIC RIGHT-OF-WAY ! 365' 2. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE MAINTAINED IN PROPER WORKING ! N/F 0 / CONDITION DURING THE PERIOD OF CONSTRUCTION. / FRANKLIN COUNTY 39 / ' /90. / II/ - --�I--// �' // // 1 - ' OB. 1190, PG. 172 --� 3. ADDITIONAL EROSION CONTROL MEASURES AND/OR MODIFICATIONS TO PROPOSED MEASURES ! ! / PB 2(110 PG 172 MAV BE NECESSARY DEPENDING ON ACTUAL SITE CONDITIONS. ! ! PIN# 18'65-52-9270 ) ' •// 4. THE TOTAL DISTURBED AREA IS 5.24 ACRES. !! / / . 5. SILT FENCE OUTLETS TO BE PLACED AS SHOWN AND AT LOW POINTS ALONG SILT FENCE AS RARY DIVERSION 2 NECESSARY ! ! 7 (SEE PERMANENT SWALE #2 PROP. TEMPFOOR CALCULATIONS) / / I ORIGINAL PLAN SIZE: 24" X 36' I- . ALL SWALES AND TEMPORARY DIVERSION DITCHES / 8. PERMANENT SWALES TO BE UTILIZED AS DIVERSION DITCHES DURING CONSTRUCTION PER EX SANITARY SEWER ! ! / 380 I/ SHALL BE STABILIZED WTHIN 7 DAYS (TVP.) CALCULATIONS ON SHEET C-3. MANHOLE(TYP)^� 1 7. SEE EROSION CONTROL CALCULATIONS ON SHEET C-3.! I \ \8. SKIMMER BASIN GRADES SHOW) ARE 2.5M:1V STARTING AT ELEVATION 389 9. CONTRACTOR SHALL ESTABLISH GROUND COVER IMMEDIATELY AFTER DISTURBANCE �iP \ \Y// ` - 8 DURING CONSTRUCTION Of PERMANENT SWALES AND OTHER IMPROVEMENTS ON THE 1 \ \\\/\ \ \ / I' / 1 \ 1 - O C) ! D E \ �1L I ( ISSUED FOR / \\\ \\ �j�� PROP. TEMPORARVDIVERSIONi 11 / -' \� WF I W PERMITTING 10.PLOPE AT TRANSITION AT TEMPORARY DIVERSION ENTRANCE TO BASIN -LINE THE"'���111iii--- r JOHN WILLIAM POPE DO NOT USE FOR CONSTRUCTION SLOPE AT ENTRANCE WITH 12' ROCK RIPRAP. / \ V \\ .�\ `Lj ALL SWALES AND TEMPORARY gVERSIDNS / \ . FOUNDATION I Q TO BE STABILIZED WTHIN 7 DAYS (TVP.) /\ CONSTRUCTION SEQUENCE / \\ \ \\ 3jo• / I / '71` J l \ \ P/N# 2016, PG 396 \ PHASE 1 \\ f� \\\ I r ( ' \ J�-O _. / 1. OBTAIN NCDEQ LAND DISTURBANCE PERMIT AND SCHEDULE A PRE -CONSTRUCTION MEETING \ \ \ 1`` .IJ SKIMMER BASIN SLOPE 11 J _ � ~ ( O 4 I - 40 20 0 40 j SCALE. 40 FEET NTH A RALEIGH REGIONAL OFFICE LAND QUALITY INSPECTOR A MINIMUM OF 72 HOURS PRIOR X\/'�'�' \ \ \ MATTING TO BE NAG '' I I I N SCALE ADJUSTMENT TO CONSTRUCTION BEGINNING. ADDITIONALLY, THE RALEIGH REGIONAL OFFICE MUST BE EX SANITARY SEWER LINE (TYP.) J '\ \ 1 3,_ \ 575, OR APPROVED " �� RALEIOTIFGH H REGI AT NALAST OFF48 ICE E AT 91 OR TO COMMENCING LAND DISTURBANCE. CONTACT THE (SIZE AND MATERIAL UNKNOWN) EQUAL; SLOPES SHALL LS t ING1IN lENGrH RALEIGH REGIONAL OFFICE AT 9137911200 \ /�_ \ JJ. w- BE STABIUZED WTHIN 7 I ON ORIGINAL GNAWING 2. INSTALL CONSTRUCTION ENTRANCE, AND WHEN COMPLETE INSTALL THE PERIMETER MEASURE / \\ �_ \ " DAYS (TVp. I I 11 INCLUDING SILT FENCE, DIVERSION DITCHES AND THE SKIMMER SEDIMENT BASIN- UPON / \ ROP. BAFFLE COMPLETION OF INSTALLATION, IMMEDIATELY SEED, MULCH, AND ANCHOR EROSION AND I \ �� \ ` 8 R IT I,5 NGT 1 INCH GN THIS w, SEDIMENTATION CONTROL MEASURES. TEMPORARY DIVERSIONS SHALL BE LINED WTH / \ \ ! 85,' I (TVP.) / I SHEET. AOIUST NGLY SLP1E TEMPORARY LINERS AS SHOWN IN THE TABLES ON SHEET C-3 AND STABILIZED WITHIN 7 DAYS. V � AV / � � I f - n� I / \ _ _ -I I AccoRaNGLr 3. BEGIN CLEARING AND ROUGH GRADING OF SITE. ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED WTHIN THE SAME DAV, WITH SPOIL PLACEMENT ON UPSLOPE SIDE. �, . \ 11 o I I PHASE 2 CONSTRUCTION PLANS I kv xvmss 4. INSTALL PROPOSED STORM DRAINAGE NETWORK AND INLET PROTECTION AS SHOWN ON THE ! S t I CRAWFORD TOWNES ! P \ \ \/-��---- 36s NC HWY 56 PLANS. ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED WITHIN THE SAME DAV, WTM / \ r L, 1\ PROP CUT SLOPE SPOIL PLACEMENT ON THE UPSIDE SLOPE. / --./ `3l8` \ EJl STREAM --/J/ �j TO BE GRADED AT WF / l (7Yp) { X\k` 2.5.1 STARTINGATJOHN WILLIAM POPE I FRANKLINTON, NC 27525 5, INSTALL WATER AND SEWER ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED WITHIN THE \ `� ! \ 37 B UUNBATTII'ON SAME DAV, WTM SPOIL PLACEMENT ON THE UPSIDE SLOPE. SEWER SMALL 8E INSTALLED UP TO "T\ ` ELEVATION 369 I MANHOLE q. \� \\ \ \ � \ c1 - ���'\ ( I PP.B. 7, PG. 5&59 V w // N# 18856&2472 8. INSTALL THE REMAINING SEWER, INCLUDING THE AERIAL SEVER CROSSING, BY FIRST / - ..1. � � '� PROP. SPILLWAY I CONSTRUCTING THE CONCRETE SUPPORT PIERS. TIMBER MATTING SHALL BE RUTILIZED TO / 50'TAWPAMLICO \ BERM GRADED AT 3 1 CROSS THE STREAM BANKS AFTER PLACEMENT OF THE CONCRETE SUPPORT PIERS, ARMOR / RIVER BUFFER FROM \\� \\\ 9 RE _ = \ _3bB _ I I. / I i I /� Crosswind THE STREAM BANKSWITH CLASS I RIP RAP AS SHOWY ON THE DETAILS ON SHEET C-16. ! TOPOF 8'.4 NK (7YPJ . 50• COMPLETE THE SEWER INSTALLATION. / \ \ AR YARD_ 365SKIMMER tt sEre Development 7. BEGIN FINISHED GRADING FILLING AND COMPACTION OF SITE. ��`\\\ �6 \\ \ \\\ 'I..� ._ACK Bnsl�Ni. NOTIFICATION OF COMBINED SELF-MONITORING AND \\8 \SID 1 l ' STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WTM PAVEMENT AND SELF -INSPECTION FORM `� _ �.I \ \ ` •380. PROP. SKIMMER INV. OUT 363'; DATE207-2017 VEGETATION. SEE SHEET C-14 FOR SEEDING SCHEDULE. `� \ \ THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2008 TO REQUIRE THAT PERSONS SCALE: AS SHOWN PROP RIPRAP DISSIPATOR 9. ONCE SITE HAS BEEN STABILIZED, CONVERT SKIMMER BASIN TO STORMWATER WETLAND AS ` \ J� `u�m LENGTH: 7.5' RESPONSIBLE FOR LAND -DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO DESIGNED BY. FLM \ \ \ APPLICABLE BY REMOVING ACCUMULATED SEDIMENT BY MEANS OF A SILT BAG AND GRADING A \�=� A_' W DTH: 3.75' MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES SHOWN ON SHEETS C-13 THROUGH C-17. q \i �� -' (, CLASS B RIPRAP5'DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. APPROVED BV: FLM t\ a� = 27'THICK PROJECT NO.: 17022 10. THE CONSTRUCTION OF THE PROPOSED STORMWATER WETLAND AND ASSOCIATED RETAINING \ �� / _ it TO SIMPLIFY DOCUMENTATION OF SELHNSPECTION REPORTS AND NPDES SELF-MONITORING REPORTS, Dm WALL SHALL NOT BEGIN UNTIL THE SITE IS FULLY STABILIZED. EX VARIABLE WIDTH .n - -J AND DEMUR DEVELOPED A COMBINED FORM. THE SELF -INSPECTION PROGRAM IS SEPARATE FROM THE GREENWEASEMENT AVC \\\ A \ \S PROP. I W DE SPILLWAY TO BE I WEEKLY 5 -ELF -MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES \ LINED WTH NAG SC250, OR `S 11 INLET PROTECTION SHALL REMAIN UNTIL THE SITE IS FULLY STABILIZED. EASEMENT FRANKLIN COUNTY \ \ APPROVED EQUAL. - THE FOCUS OF THE SELF -INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND EROSION &SEDIMENT CONTROL D B. 1198, PG. 217 \ _ _ SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS SHOULD BE - PHASE 1 12. UPON COMPLETION AND APPROVAL By NCDEQ, REMOVE ANY REMAINING EROSION CONTROL p. B. 2010, PG. 172 \ \ _ CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER IS MEASURES. PIN# /86552-9270 \\ S \ o ESTABLISHED. THE FORM CAN BE -ACCESSED AT: 13. ALL DISTURBED AREAS TO BE STABILIZED AND GROUNDCOVER SHOULD BE ACHIEVED WITHIN 11 \\ \\\ / i I PJIDE .NC.GOV/ABOUT"\ASIONSIENERGY-MINERAL-IANDRESOURCESlERO510NSEgMENT-CONTROL/FORMS / _ WORKING DAYS, FOLLOW NG COMPLETION OR DEVELOPMENT PER NPDES CONSTRUCTION \ \\ 1 \V- STORMWATER GENERAL PERMIT NCG010000. \ a� \ `� \ /' IF VO HAVE UESTI S OR ANNO .`CCE S THE ORM, EASE ONTA THE LEIG REGIO AL OF CE O 1017 THIS DRAWING SHALL NOT W REPRODUCED IN W HOLE p IN AT (819) 79112(X7. PART WITHIXIT WR71'TEN PERMISSKIN OF FLM ENGINEERING, MC. SHEET 7 OF 17 LEGEND EX. PROPERTY LINE EX RIGHT -OF -WAV - - - - - - EX. ADJACENT OWNERS - - - - - - - - EX. EASEMENT - EX. ROAD CENTERUNE EX. CHANNEUSTREAM w - W _ W - W - W y 6100 pUeL/C B (ERg ' KEEN +- m -.• - - _ -- _ o� �. _ APPROX. LOCATION ENGINEERING - EX. CHANNEUSTREAM BUFFER - -- EX. CHAIN LINK FENCE r F" r -I �- _� - EX 16'WATERL/NE - I I EX DRIVEWAY TO / ` �II7; �_ -OHW-OHW- EX. OVERHEAD ELECTRIC LINE rur. � I I BE CLOSED / q'' �` (DEPTH UNKNOWN) '4�R ^�" r.INxir RBN1Hra I � � /f � � � - _ -- -- \ � _ POST OFFICE BOX 91727 W - W - EX. WATER LINE -- - ---- -- --... - _-_---_-_ _ - --_--- I 1 ABANDONED EX SAN/TARY S` �� \ \ ` \\ RALEIGH. NORTH CAROLINA 27675 SEWER MANHOLE TYP PROP. x ^� - SS - SS EX. SANITARY SEWER rFF'�+ r ,'r`�"s I waA+N� . I ; ) 1 / / / CONCRETE 7-�- J / _ ��- , \ FIRM NCLICENSE NUMBER C4222 _ VVV -- p� 1 PHONE: 919.610.1051 / �i� EX FENCE AND EDGE OF --� / WASHOUT PIT IV \ \ SD - SD EX. STORM SEWER -- --- - - - --- - -- - - --- - -- - - ----- 1 ASPHALTPAVEMENT l - Hw L.v':a�uy. ry.uwn>Hrr.r.rr.w, 1 1 �/ - / �- 25�FItON 1 EX. TREE LINE \ / / T YAC SETBgC DNA, \ W \ '/ PROP. LOT LINES ��uw.rwr.rrrrewH, urN rrrF.r.rlwr 1 1 __�t� K --- - - - - PROP. SETBACK UNE _ 1 1 i� ' PROP. LIMITS OF STAGING, / / OlyW�\ /�� STOCKPILE, AND/OR CONCRETE 9 W ----- --- - WASHOUT AREA LOCATED 50' 3 / \ '• PROP. EASEMENT 1 1�/ / IY 325 PROP. MAJOR CONTOUR (5') 1 / / / �i FROM STORM DRAINS AND 1 / / I l % Dl'IW :'. .- •,,, Z i i� 1 SURFACE WATERS / PROP. 24 x 100 TEMPORARY . / - 324 PROP. MINOR CONTOUR (1') I w my c CONSTRUCTION ENTRANCE 395' = /•" ✓L - -- W - - W --- PROP. WATER LINE f / J \ _SS -SS - PROP. SANITARY SEWER iQ I //"1 \ / - \ / / �'•: - PROP. STORM SEWER' PROP. TEMPORARY DIVERSION 3 / Sys, - / 390' - PROP. CURB INLET (SEE PERMANENT SWALE #1 FOR CALCULATIONS) / PROP. INLET cm PROP DIVERSION DITCHES PROTECTION (TVP) ALL SWALES AND TEMP. PROP. FLARED END SECTION ' � LD - LD PROP. LIMIT OF DISTURBANCE / / Y TOWN OF FRANN I SHALL BE STABILIZED WITHIN 7 DAYS (TVP. CB -1 /m0 REVISION HISTORY - » 1D » - PROP. TEMPORARY DIVERSION DITCH 0' SANITARY SEWERSEWER �I I EASEMENT I SF SF PROP. SILT FENCE I I It CB -2 t/ /W / 385' # DESCRIPTION DATE B` -x-%-K-Ic-x-%X-%- PROP. BAFFLE / 1 /1 F / ADDRESS NTS1/17J2018 FL EO -� PROP. FAIRCLOTH SKIMMER I / / l l W JOHN WILLIAM POPE l - PROP. SLOPE PROTECTION l / D.B. 208. PG. 96 I COMMENTS 1/23/2018 FLI / $ / 1ADDRESS NCDEQ 3 2 ® PROP -CONSTRUCTION ENTRANCE I I ^ 2/12/2018 FLI I N# 17. -6 57 3 ADDRESS FCPU PROP. HORSESHOE INLET PROTECTION/CHECK DAM I I l / 380' PIN# i86Se6-3841 / COMMENTS ® PROP. SILT FENCE OUTLET ❑ PROP. INLET PROTECTION / EROSION CONTROL NOTES PROP. SILT FENCE -1--� / / 1. ALL LAND DISTURBING ACTIVITIES SHALL BE CONDUCTED IN ACCORDANCE WITH NCDEQ It WAY I I l EX CONCRETE PAD CB -3 (TYP.) _ / 375' STANDARDS.- 40' PUBLIC RIGHT-OF-WAY 1 365 2. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE MAINTAINED IN PROPER WURKING I I WF PROP. CHECK DAM / CONDITION DURING THE PERIOD OF CONSTRUCTION. - - , - I / FRANKLIN COUNTY /\�- C84 b ( / (TYR) OB 1198, PG. 217 r / 3. ADDITIONAL EROSION CONTROL MEASURES AND/OR MODIFICATIONS TO PROPOSED MEASURES I ( / P 8. 010, PG. 172 0 / �S• v g8 MAY BE NECESSARY DEPENDING ON ACTUAL SITE CONDITIONS. I I PIN 186552-9270 4. THE TOTAL DISTURBED AREA IS 5.24 ACRES. - - - - - - - -- -I� PROP. TEMPORARY DIVERSION 2 I _ (SEE PERMANENT SWALE #2 FOR CALCULATIONS) 5. SILT FENCE OUTLETS TO BE PLACED AS SHOWN AND AT LOW POINTS ALONG SILT FENCE AS I / / W / '{'pj / / / - ALL SWALES AND TEMPORARY DIVERSION DITCHES I ORIGINAL PLAN SIZE: 24" X 36" NECESSARY. SHALL BE STABILIZED NATHIN 7 DAYS (TVP.) EX SANITARY SEWER l I / 380' p/ 1 6. PERMANENT SWALES TO BE UTILIZED AS DIVERSION DITCHER DURING CONSTRUCTION PER CALCULATIONS ON SHEET C-3. MANHOLE (11'P) I i / 7, SEE EROSION CONTROL CALCULATIONS ON SHEET C-3 L PROP. HORSESHOE INLET I I \ /\ PROTECTION (TVP) 8. SKIMMER BASIN GRADER SHOWN ARE 2.SM:1V STARTING AT ELEVATION 369. \\ \ 9. CONTRACTOR SHALL ESTABLISH GROUND COVER IMMEDIATELY AFTER DISTURBANCE \ iP CB -5 DUURING CONSTRUCTION OF PERMANENT SWALES AND OTHER IMPROVEMENTS ON THE 1 \ sit C86\/ t // \ \ I O O I ISSUED FOR \ ,rt ,1/,F ) u � PERMITTING 10. PROVIDE STABLE TRANSITION R TEMPORARY DIVERSION ENTRANCE TO BASIN -LINE THE \\ V \\\ _- I pl-7 �', - \ JOHN WILLIAM POPE ( Q DO NOT USE FOR CONSTRUCTION SLOPE AT ENTRANCE WITH 12' ROCK RIPRAP. Lq ,,- CONSTRUCTION SEQUENCE \\ 370. ! / \ Q l ? oB 2016A c 396 Q - J 'o. PIN# 186566-2587 \ U 1. OBTAIN NCDEO LAND DISTURBANCE PERMIT AND SCHEDULE A PRE -CONSTRUCTION MEETING / \ \ I T S / I Q m 40 20 0 40 PHASEI \ \ v- / \\ \ / 1 KIMMER BASIN SLOPE / ( �� I SCALE: 1INCH=40 FEET WITH A RALEIGH REGIONAL OFFICE LAND QUALITY INSPECTOR A MINIMUM OF 72 HOURS PRIOR X\/'��-" \ I. / MATTING TO BE NAG V SCALE ADJUSTMENT TO CONSTRUCTION BEGINNING. ADDITIONALLY, THE RALEIGH REGIONAL OFFICE MUST BE EX SANITARY SEWER LINE (NPJ-/--fff l \ 575, OR APPROVED / FO NOTIFIED AT LEAST 48 HOURS PRIOR TO COMMENCING LAND DISTURBANCE. CONTACT THE (SIZE AND MATERIAL UNKNOWN \ \ l_ EQUAL; SLOPES SHALL ( TIM BAR IS 1 INCH IN LENGn RALEIGH REGIONAL OFFICE AT 91 9-791 4 20 0. ) BE STABIUZED WITHIN 7 - I ON ORIGINAL IXUWING \ / DAYS (TYR) 2. INSTALL CONSTRUCTION ENTRANCE, AND WHEN COMPLETE INSTALL THE PERIMETER MEASURE / \ \\ / .L I INCLUDING SILT FENCE, DIVERSION DITCHES.AND THE SKIMMER SEDIMENT BASIN. UPON / I \ J` \ ROP. AFFL \\ �n \ �S IF RIS HOT 1 INCH ON TIp COMPLETION OF INSTALLATION, IMMEDIATELY SEED MULCH, AND ANCHOR EROSION AND / (TVP.) " \ I SHEET. ADJUST -R SLUE SEDIMENTATION CONTROL MEASURES. TEMPORARY DIVERSIONS SHALL BE LINED HIN - J ACCCFDINGLv TEMPORARY LINERS AS SHOWN IN THE TABLES ON SHEET C-3 AND STABILIZED WITHIN 7 DAYS. \ \ \� / i� CB -9 ^� I / I I PROP. 20' 1 JI - 3. BEGIN CLEARING AND ROUGH GRADING OF SITE. ALL EXCAVATIONS PERFORMED SHALL BE \ / ' `\ tr�/ \ FRANKLIN COUNTY �/ ' CONSTRUCTION PLANS BACKFILLED WITHIN THE SAME DAV, WITH SPOIL PLACEMENT ON UPSLOPE SIDE. \ "VV U' \ SANITARY SEWER I ' " FE$2 i / / I I I PHASE 2 \ D= Al \ EASEMENT S / \ 4. INSTALL PROPOSED STORM DRAINAGE NETWORK AND INLET PROTECTION AS SHOWN ON THE / `\ \ ti\ '. /' 1 \ \\; \\� / f�-(\' X\�-` ^ PROP. CUT SLOPE j' I I CRAWFORD TOWNES PLANS. ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED WITHIN THE SAME DAV, WATH / �\ r' / \ .y'ry TO BE GRADED AT N/F I NC HWY 56 SPOIL PLACEMENT ON THE UPSIDE SLOPE. / .)' `2l0 \ EX. STREAM �/ �\ X. 2.51 STARTING AT I II X JOHNWauAMPOPE FRANKLINTON, NC 27525 (TYP) 1 / ' �� / - X'�X\ ELEVATION 389 5, INSTALL WATER AND SEWER ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED NATHAN THE \ T 37 - FOUNDATION SAME DAY WITH SPOIL PLACEMENT ON THE UPSIDE SLOPE. SEWER SHALL BE INSTALLED UP TO / �� \ \ `PjI \\ i\X\1� XCX I / D. 018 PG. 396 I I MANHOLE K1 Jg P.B. 7. PG. 58-59 If 0 � ' \^\ `A /" \- m X�� , _. j.. / ',, I PIN#186&6&2472 6, INSTALL THE REMAINING SEWER, INCLUDING THE AERIAL SEWER CROSSING, BY FIRST / PROP SPILLWAY CONSTRUCTING THE CONCRETE SUPPORT PIERS. TIMBER MATTING SHALL BE UTILIZED TO / 50' TAR/PAMLICO \ Z' s. _ `/�J �, BERM GRADED AT 3'1 CROSS THE STREAM BANKS. AFTER PLACEMENT OF THE CONCRETE LS ONSUPPORTSH PIERS, ARMOR RIVER BUFFER FROM \ 366 I \ I / I I I Crosswind THE STREAM BANKS WITH CLASS RIP RAP AS SHOWN ON THE DETAILS ON SHEET C-16. / TOPOF BANK (TYP) \ /Q v_ \ J / COMPLETE THE SEWER INSTALLATION. / \ �`\( (L)\� v �REgR 1.Ro g�.BAC 365 PROP.SKIMMER 7. BEGIN FINISHED GRADING, FILLING,AND COMPACTION OF SITE. ��,765• I K � H/ BAST\N i'_NOTIFICATION OF COMBINED SELF-MONITORINGAND%9%,ODevetopment 8. STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH PAVEMENT AND %I `l; SELF -INSPECTION FORM �, \ \' 36p, o, ` DATE: 12-07-017 VEGETATION. SEE SHEET C-14 FOR SEEDING SCHEDULE. N \ ` PROP. SKIMMER INV. OUT 363; SCALE: AS SHOWN \ - PROP. RI PRAP DISSIPATOR THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS 8. ONCE SITE HAS BEEN STABILIZED, CONVERT SKIMMER BASIN TO STORMWATER WETLAND A8 o, `� � � LENGTH: 7.5' RESPONSIBLE FOR HE APPROVED ER ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE FO THE PROJECT TO DESIGNED BY: FLM APPLICABLE BY REMOVING ROUGH -17 SEDIMENT By MEANS OF A SILT BAG AND GRADING A ` \ \ ` F WIDTH: RI MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES PROVED BY: FLM SHOWN ON SHEETS C-13 THROUGH C-17. \ " (' ' CLASS B RIPRAP DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. \\ r� ,) 22" THICK PROJECT NO.: 17022 10. THE CONSTRUCTION OF THE PROPOSED STORMWATER WETLAND AND ASSOCIATED RETAINING \ \ \ r - -/) TO SIMPLIFY DOCUMENTATION OF SELF -INSPECTION REPORTS AND NPDES SELF-MONITORING REPORTS, DNR EX VARIABLE WIDTH `�, / ' �! AND DEMLR DEVELOPED A COMBINED FORM. THE SELF4NSPECTION PROGRAM IS SEPARATE FROM THE WALL SHALL NOT BEGIN UNTIL THE SITE IS FULLY STABILIZED. GREARIABL WIDTH DTH N/F \\ ' \I -�� PROP. 30' WADE SPILLWAY TO BE o / \ \ LINED WITH NAG SC250,OR / WEEKLY SELF-MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. EROSION& SEDIMENT CONTROL 11ANLET PROTECTION SHALL REMAIN UNTIL THE SITE IS FULLY STABILIZED. EASEMENT FRANKLIN COUNTY `, `\\ \ APPROVED EQUAL. THE FOCUS OF THE SELF4NSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND D 8. 1198, PG. 217 \ \ SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS SHOULD BE -PHASE 2 12. UPON COMPLETION AND APPROVAL BY NCDEQ, REMOVE ANY REMAINING EROSION CONTROL P.B 2010, PG. 172 \ \ _ CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER I6 MEASURES. P/N# iB6S52-9270 \\ \ ESTABLISHED. THE FORM AN BE ACCESSED AT: C-8 \ 13. ALL DISTURBED AREAS TO BE STABILIZED AND GROUNDCOVER SHOULD BE ACHIEVED WTHIN 14 \\ \\\\\ `\ \ 1 HRPJIDE .NC.GOV/ABOU7/DIWSIONSIENERGY-MINERAL A ANDRESOURCESIEROSIONSEDIMENT-CONTROL/FORMS / ' - Q WORKING DAYS, FOLLOWING COMPLETION OR DEVELOPMENT, PER NPDES CONSTRUCTION I \ 1 \�/� (Vl STORMWATER GENERAL PERMIT NCG010D00. \ \ \ IF VO HAVE UEBTI NS OR ANNO ACC S THE ORM, EASE ONTA THE LEIS EGIO AL OF CE ( AT(919)791 4200, D17 TNM DRAWING SNALL NOT BE REPRODUCED IN WHO11-IN IT WITHOUT WRITTEN PERMIS,pN OF FW ENGINEERING. WC. SHEET 8 OF17 FLM NOTES 1. THE WETLAND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION. CONSTRUCTION SHALL BE SEQUENCED SO THAT VEGETATION CAN BE PLANTED AND THE WETLAND BROUGHT ONLINE WITHIN 14 DAYS. PLANTS MAY NEED TO BE WATERED DURING THIS TIME IF THE DEVICE IS NOT BROUGHT ONLINE THE SAME DAY. STABILIZATION MAY BE IN THE FORM OF FINAL VEGETATION PLANTINGS OR A TEMPORARY MEANS UNTIL THE VEGETATION BECOMES ESTABUSHED. IF USING A TEMPORARY MEANS, CONTRACTOR SHALL PROVIDE A WET HYDROSEED MIX. CONTRACTOR SHALL SCARIFY THE SOIL TO A HALF-INCH PRIOR TO HYDROSEEDING. 2. INLET AND OUTLET CHANNELS SHALL BE PROTECTED FROM SCOUR THAT MAY OCCUR DURING PERIODS OF HIGH FLOW STANDARD EROSION CONTROL MEASURES SHOULD BE USED. 3. THE STORMWATER WETLAND SHOULD BE STAKED AT THE ONSET OF THE PLANTING SEASON. WATER DEPTHS IN THE WETLAND SHOULD BE MEASURED TO CONFIRM THE ORIGINAL PLANTING ZONES. AT THIS TIME, IT MAY BE NECESSARY TO MODIFY THE PLANTING PLAN TO REFLECT ALTERED DEPTHS OR THE AVAILABILITY OF WETLAND PLANT STOCK CONTRACTOR SHALL COORDINATE PLANTINGS, PLANTING ZONES AND WATER DEPTHS WITH THE ENGINEER. SURVEYED PLANTING ZONES SHOULD BE MARKED ON AN 'AS-BUILT'OR RECORD DESIGN PIAN AND LOCATED IN THE FIELD USING STAKES OR FLAGS. 4. THE WETLAND DRAIN SHOULD BE FULLY OPENED FOR NO MORE THAN 3 DAYS PRIOR TO THE PLANTING DATE (WHICH SHOULD COINCIDE WITH THE DELIVERY DATE FOR THE WETLAND PLANT STOCK) TO PRESERVE SOIL MOISTURE AND WORKABILITY. 5. NURSERY STOCK SHALL BE TRANSPLANTED FROM LOCAL AQUATIC PLANT NURSERIES. THE OPTIMAL PERIOD FOR TRANSPLANTING EXTENDS FROM EARLY APRIL TO MID -JUNE SO THAT THE WETLAND PLANTS WILL HAVE A FULL GROWING SEASON TO BUILD THE ROOT RESERVES NEEDED TO SURVIVE THE WINTER. HOWEVER SOME SPECIES MAY BE PLANTED SUCCESSFULLY IN EARLY FALL. CONTRACTOR SHALL CONTACT NURSERY WELL IN ADVANCE OF CONSTRUCTION TO ENSURE THAT THEY WALL HAVE THE DESIRED SPECIES AVARABLE. 6. POST -NURSERY CARE OF WETLAND PLANTS IS VERY IMPORTANT IN THE INTERVAL BETWEEN DELIVERY OF THE PLANTS AND THEIR SUBSEQUENT INSTALLATION BECAUSE THEY ARE PRONE TO DESICCATION. STOCK SHOULD BE FREQUENTLY WATERED AND SHADED 7. SHWT TO BE EVALUATED PRIOR TO CONSTRUCTION. IF SHWT IS WITHIN 6' OF PPE ELEVATION, A CLAY LINER WILL NOT BE REQUIRED. OTHERWISE, INSTALLATION OF A S' CLAY LINER WILL BE REQUIRED. CLAY LINER SHALL HAVE A MINIMUM 15% PASSING THE 8210 SIEVE AND A MAX PERMEABILITY OF 1 X 10° CM/SEC. ACCEPTABLE ALTERNATIVES INCLUDE A 30 MIL POLY -LINER OR A BENTONITE LINER. 8. GRADES SHOWN REPRESENT FINISH GRADE ELEVATIONS TO ACHIEVE FINISH GRADE ELEVATIONS INSTALL 4'OF TOPSOIL. 9, PROVIDE PLANTS PER TABLE ON THIS SHEET DAM STRUCTURE AND PERIMETER FILL SLOPES SHALL BE PLANTED WITH NON -CLUMPING TURF GRASS. TREES AND WOODY SHRUBS NOT ALLOWED. % CATTAILS SHALL NOT BE PLANTED IN WETLAND. OUTLET STRUCTURE NOTES & SPECIFICATIONS 1. RCP OUTLET SHALL BE CLASS III RCP MEETING REQUIREMENTS OF ASTM C76. THE PIPE JOINTS SHALL BE MORTAR OR FLEXIBLE PLASTIC TYPE JOINT 2, THE MANHOLE OUTLET RISER SHALL MEET ASTM C-913. THE MANHOLE JOINTS SHALL BE ASTM 0443 RUBBER GASKET JOINTS. MANHOLE JOINTS SHALL BE SECURELY ANCHORED TO PREVENT SEPARATION. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE MANHOLE SECTION ANCHORING SYSTEM. 3. WATERTIGHT SEAL SHALL BE PROVIDED AT RISER/BARREL INTERFACE. PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE SHALL NOT BE USEDAS BACKFILL AROUND THE PIPE OR ANTI -SEEP COLLAR. FILL MATERIAL AROUND THE RISER/BARREL STRUCTURE SHALL BE PLACED IN 4" LAYERS AND COMPACTED TO THE SAME DENSITY AS THE ADJACENT EMBANKMENT. 4. OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS V-2' ON CENTER. STEPS SHALL BE IN ACCORDANCE WITH "COOT STD. 840.66. 5, CONCRETE ANTI -FLOATATION BLOCK SHALL BE PRECAST DURING FABRICATION. IF THE CONCRETE ANTI -FLOATATION BLOCK IS CAST SEPARATE FROM THE MANHOLE ASSEMBLY THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANCHORING THE ANTI -FLOATATION BLOCK TO THE MANHOLE RISER ASSEMBLY. 6. ALL POURED CONCRETE SHALL BE A MINIMUM 3,000 PSI(28 DAY) UNLESS OTHERWISE NOTED. 7. NON -WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AROUND EACH JOINT OF THE RCP OUTLET BARREL IN 7 WIDE STRIPS CENTERED ON JOINT. FABRIC SHALL BE AMOCO STYLE 4553 POLYPROPYLENE NON -WOVEN NEEDLE PUNCHED OR APPROVED EQUAL (NON -WOVEN FABRIC). BERM SPECIFICATIONS I . ALL FILL SOILS FOR BERM SECTION SHALL BE CLEAN, IMPERMEABLE MATERIAL AND COMPACTED TO AT LEAST 98% STANDARD PROCTOR MAXIMUM DRY DENSITY, AT OPTIMUM MOISTURE CONTENT. NO BLASTED MATERIALS SHALL BE USED IN THE EMBANKMENT CONSTRUCTION. SOILS SHALL NOT EXHIBIT SIGNIFICANT SHRINK/SWELL OR DISPERSIVE CHARACTERISTICS. THE ONSITE GEOTECHNICAL ENGINEER SHALL APPROVE THE SOILS FOR PLACEMENT WITHIN THE BERM SECTION. THE GEOTECHNICAL ENGINEER SHALL ALSO SPECIFY THE METHODS TO BE USED FOR PLACEMENT OF FILL 2. IN ALL FILL AREAS OF THE BERM, A SOILS COMPACTION TEST SHALL BE CONDUCTED EACH 2,500 SQUARE FEET PER VERTICAL CUT OF FILL. 3. A KEY TRENCH IS TO BE PROVIDED IN ALL FILL AREAS. TRENCH TO EXTEND A MINIMUM OF TWO FEET BELOW EXISTING GRADE. THE MINIMUM BOTTOM WIDTH SHALL BE WADE ENOUGH TO PERMIT OPERATION OF EXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE SHALL BE LESS THAN 7 WIDE. CONTRACTOR SHALL CONFIRM KEY TRENCH DEPTH AND WIDTH WITH THE ON-SITEGEOTECHNICALENGINEER. SOILS AND COMPACTION FOR KEY TRENCH SHALL MEET ALL REQUIREMENTS OF #1 ABOVE. 4. FILL PLACEMENT SHALL NOT EXCEED A MAXIMUM OF B' LIFTS. EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. 5, NO TREES OF ANY TYPE MAY BE LOCATED ON THE BERM SECTION. 6. WEIR SHALL BE LINED WITH NORTH AMERICAN GREEN SC250 MATTING, OR APPROVED EQUAL. 7. SIDE SLOPES SHALL BE LINED WITH NAG S75, OR APPROVED EQUAL. 8, INSTALL ANTI -SEEP COLLAR AT MIDPOINT OF OUTLET PIPE. CONCRETE SHALL BE 3,000 PSI (28 DAYS) AND REINFORCED WITH #4 REBAR 17' O.C. EACH WAY. MINIMUM BEARING CAPACITY BENEATH COLLAR SHALL BE ZODO PSF. 41, 1 ` PROP. 20'FRANKLIN COUNTY SANITARY (' SEWER EASEMENT TW376.00' �(\ BW 369.00' 376.00' _ BW 369.00' `TW 375.00' BW369.00' 366 �`.. / � y. •�/�1 Q 365 365 00'X 364.50 X 364 50' X ,. 364,21' X BW 369 369.00' `/v\/ 364.50'X _._ \ .00' � 364.50' X V ~. \ 36d.2S' X-- 365.00' X .4!;0 X 365/ PROP 30 LF WEIR AT ELEV. 367.00' , I B' / K LINED WITH NAG P300\\ X }\ A f (OR APPROVED EQUAL) \ •PROP. 30 LF 15' RCP \ OUTLET PIPE Q 1.67% PRO IN OUTS Lo l_ �1 1 PROP. RIPRAP ENDISSIPATOR ERGY J CLASS B IF RAP 27' THICK LENGTH 7 5'; WIDTH. 3.75' +L 3H:1V(TYP.) i STORMWATER WETLAND PLAN VIEW SCALE. 1" =20 PROP. RETAINING WALL (DESIGN BY OTHERS) PROP. 5'X 5' PRECAST CONCRETE RISER STRUCTURE 4' X 4' GRATE ELEV. = 360.25' 1 - 2" ORIFICE ELEV. = 365.00' 15" INV OUT = 363.50' PROP. 7' SCHED 40 PVC W/ 90* TURNDOWN INV 365.00' 77 PPE ELEV 365' i '\ 12' DEEP POOL STORMWATER WETLAND PLANTING TABLE I I I , 6" #57 STONE BEDDING I 9 x BOTANICAL NAME COMMON NAME SIZE SPACING I PLANTINGS (AREA = 2,568 SO. FT., 50 HERBACEOUS PLANTS PER 200 SO FT., 642 TOTAL PLANTS REQ.) PROP. VARIABLE WIDTH PRIVATE / / ACCESS & MAINTENANCE(EASEMENT I 11 / TW 369.00' I _ 365' I HYDROLEA QUADRIVALVIS WATERPOO 4CU. IN. 2'0.C. 128 PROP. 4'TALL BLACK 4 CU. IN. 9 ALUMINUM FENCE TO SURROUND SCM 129 I` I 14 I tl PROP. 10' WIDE J /� / DOUBLESWINGGATE 4CU. IN. 2' O.C. SHALLOW LAND PLANTINGS (AREA = 1,924 SO, FT., 50 HERBACEOUS PLANTS PER 200 SO, FT.; 481 TOTAL PLANTS REO) 160CAREXTENERA PROP. 5'X 5' OUTLET I STRUCTURE I 4CU. IN. +L 3H:1V(TYP.) i STORMWATER WETLAND PLAN VIEW SCALE. 1" =20 PROP. RETAINING WALL (DESIGN BY OTHERS) PROP. 5'X 5' PRECAST CONCRETE RISER STRUCTURE 4' X 4' GRATE ELEV. = 360.25' 1 - 2" ORIFICE ELEV. = 365.00' 15" INV OUT = 363.50' PROP. 7' SCHED 40 PVC W/ 90* TURNDOWN INV 365.00' 77 PPE ELEV 365' i '\ 12' DEEP POOL T 3" TO 6" SHALLOW WATER 7 DEEP POOL STORMWATER WETLAND PLANTING TABLE - - - - - - 6" #57 STONE BEDDING QUANTITY BOTANICAL NAME COMMON NAME SIZE SPACING SHALLOW WATER PLANTINGS (AREA = 2,568 SO. FT., 50 HERBACEOUS PLANTS PER 200 SO FT., 642 TOTAL PLANTS REQ.) 8,231 20,246 128 ACORUS SUBCORDATUM ISWEETFLAG 4 CU. IN, 2' O.C. 128 HYDROLEA QUADRIVALVIS WATERPOO 4CU. IN. 2'0.C. 128 IRIS VIRGINICA BLUE FLAG IRIS 4 CU. IN. 70.C. 129 SAGITTARIA LATIFOLIA DUCK POTATO 4 CU. IN. 2' O.C. 129 SAURURUS CERNUUS LIZARD'S TAIL 4CU. IN. 2' O.C. SHALLOW LAND PLANTINGS (AREA = 1,924 SO, FT., 50 HERBACEOUS PLANTS PER 200 SO, FT.; 481 TOTAL PLANTS REO) 160CAREXTENERA QUILL SEDGE 4CU. IN. 70.C. 160 HIBISCUS COCCINEUS SCARLET ROSE MALLOW 4CU. 161 LOBELIA ELONGATA LONGLEAF LOBELIA 4 CU, DEEP POOL SHALLOW WATER AREA 30 ELEOCMARIS ACICULARIS NEEDLE SPIKERUSH RARE ROOT WA 30 NUPHAR LUTEA SSP. ADVENA YELLOW POND-ULY BARE ROOT WA T 3" TO 6" SHALLOW WATER 7 DEEP POOL 4' INSIDE - - - - - - 6" #57 STONE BEDDING 325- EX, MAJOR CONTOUR (10) 4'X 4'X1' J CONCRETE SUMP STORMWATER WETLAND CROSS-SECTION NOT TO SCALE PROP. TRASH RACK TOP OF BANK ELEV. =368.00' PROP. EMERGENCY SPILLWAY ELEV. = 367.00'; LINED WITH NAG SC250 (OR APPROVED EQUAL) ANTI -SEEP COLLAR INV OUT = 363.50' 30 LF 15" RCP @ 1.67% 1 1 1 1 2 FES INV =363.00' (MIN)i KEY TRENCH LEGEND - - EX. RIGHT-OF-WAY - - - - - - EX. ADJACENT OWNERS 325- EX, MAJOR CONTOUR (10) 61255 51799 EX MINOR CONTOUR (7) - - EX. FEMA FLOODPLAIN BOUNDARY 8,231 20,246 EX. STREAM - EX. STREAM BUFFER K EX. FENCE - OHW- OHW- EX. OVERHEAD ELECTRIC LINE EX. WETLANDS PROP. PARCEL BOUNDARY - - PROP. RIGHT -OF -WAV PROP. LOT LINES - PROP. ROAD CENTERLINE _LD -LD PROP. LIMIT OF DISTURBANCE ----------- PROP. EASEMENT PROP. WATER LINE PROP. SANITARY SEWER PROP. STORM SEWER 325 PROP. MAJOR CONTOUR (5') 324 PROP. MINOR CONTOUR (11 PROP. DRAINAGE SWALE SHALLOW LAND AREA SHALLOW WATER AREA DEEP POOL AREA STORMWATER WETLAND MAINTENANCE NOTES 1. THE LANDSCAPE PROFESSIONAL MANAGING THE WETLAND MUST UNDERSTAND THE BIOLOGICAL REQUIREMENTS OF THE PLANTS AND MANAGE WATER LEVELS APPROPRIATELY TO PROVIDE FOR THEIR NEEDS. Z ALTHOUGH WETLAND PLANTS REQUIRE WATER FOR GROWTH AND REPRODUCTION, THEY CAN BE KILLED BY DROWNING IN EXCESSIVELY DEEP WATER. USUALLY, INITIAL GROWTH IS BEST WITH TRANSPLANTED PLANTS IN WET, WELL-AERATED SOIL. OCCASIONAL INUNDATION FOLLOWED BY EXPOSURE TO AIR OF THE MAJORITY OF THE VEGETATION ENABLES THE PLANTS TO OBTAIN OXYGEN AND GROW OPTIMALLY. CONVERSELY, FREQUENT SOIL SATURATION IS IMPORTANT FOR WETLAND PLANT SURVIVAL 3. DRAMATIC SHIFTS CAN OCCUR AS PLANT SUCCESSION PROCEEDS. THE PLANT COMMUNITY REFLECTS MANAGEMENT AND CAN INDICATE PROBLEMS OR THE RESULTS OF IMPROVEMENTS. FOR EXAMPLE, A REQUIREMENT OF SUBMERGED AQUATIC PLANTS, SUCH AS PONDWEED (POTAMOG ETON SPP.), IS LIGHT PENETRATION INTO THE WATER COLUMN. THE DISAPPEARANCE OF THESE RANTS MAY INDICATE INADEQUATE WATER CLARITY. THE APPEARANCE OF INVASIVE SPECIES OR DEVELOPMENT OF A MONOCULTURE IS ALSO A SIGN OF A PROBLEM WITH THE AQUATIC/SOILNEGETATIVE REQUIREMENTS. FOR INSTANCE, MANY INVASIVE SPECIES CAN QUICKLY SPREAD AND TAKE OVER A WETLAND. IF CATTAILS BECOME INVASIVE, THEY CAN BE REMOVED BY A LICENSED AQUATIC PESTICIDE APPLICATOR BY WIPING AQUATIC GLYPHOSATE, A SYSTEMIC HERBICIDE, ON THE CATTAILS. 4. UNLIKE MAINTENANCE REQUIREMENTS FOR WET OR DRY STORMWATER PONDS, SEDIMENT SHOULD ONLY BE SELECTIVELY REMOVED FROM STORMWATER WETLANDS, PRIMARILY FROM THE FOREBAY.SEDIMENT REMOVAL DISTURBS STABLE VEGETATION COVER AND DISRUPTS FLOWPATHS THROUGH THE WETLAND. THE TOP FEW INCHES OF SEDIMENT SHOULD BE STOCKPILED SO THAT IT CAN BE REPLACED OVER THE SURFACE OF THE WETLAND AFTER THE COMPLETION OF SEDIMENT REMOVAL TO RE-ESTABUSH THE VEGETATIVE COVER USING ITS OWN SEED BANK. ACCUMULATED SEDIMENT SHOULD BE REMOVED FROM AROUND INLET AND OUTLET STRUCTURES. STAGE -STORAGE TABLE ELEVATION (FT) SURFACEAREA TOTALSTORAGE (SF) (CF) 365.00 51355 0 366.00 61255 51799 387.00 7,215 12,528 366.00 8,231 20,246 CALL 48 HOURS BEFORE YOU DIG ftAw NORTH CAROLINA ONE -CALL CENTER 1 -Ann _R1O -AO ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.61 0 .1051 FIRM NC LICENSE NUMBER C4222 �OPSH- =; Z, 8 .rr.r.. REVISION HISTORY REV DESCRIPTION DATE BY 1 ADDRESS NCDEQ j/12/2018 COMMENTS FLM 2 ADDRESS NCDEO COMMENTS 1/2312018 FLM ADDRESS FCPU 3 COMMENTS 3112/2018 FLM ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 20 10 0 20 SCALE: 1 INCH = 20 FEET N SCALE ADJUSTMENT THIS BAR IS t INCH IN LENGTH OU ORIGINAL I-ING 0 I W IT IS NOT t INCH ON THIS SWEET. ADJUST YOUR S -E ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 Crosswind W Development DATE: 12-07-2017 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 STORMWATER MANAGEMENT DETAILS C-9 SHEET 9 OF 17 fill 1 1 1 111 EX. PROPERTY LINE PROP. VARIABLE WIDTHPUBLIC w�� UTILITY EASEMENT ila-6 zi ZSTA: 0+70.41 EX. MINOR CONTOUR (1') - - - - - - 03 --------- N ELEV'. 399.31 Ir ADDRESS NCDEO EX. ROAD CENTERLINE - 2 GA'3 m o'3 I I EX. CHANNEUSTREAM BUFFER ADDRESicurc U 2/12/2018 FLM I m - OHW- OHW- �sSEEN LVC: 100.00 E 113 EX. WATER LINE �,�®III\�. �il��filial►�. �II®.i�ll`ii��ii!� EX. SANITARY SEWER 11 EX. STORM SEWER PRO VAR OP.VAI IABLE DTH PRIVATE UTILITY EASEMENT qr 40( i1t m m C D 0 Z 380 370 360 35S EX SANITARY,, SEWER LINE (TYP.) / 365 (S/ZE ANO MATERIAL I / UNKNOWN) /I/ / / PROP. 20' FRANKLIN /I ( COUNTY SANITARY � / I SEWER EASEMENT � I PROP CONCRETE PIER Q STA 7+20.72 (8'x 3' FOOTING) 3 I y I EX SANITARY SEWER MANHOLE TOP = 370.83' INV IN=36252' INV. OUT = 362 23' EX. PROPERTY LINE + F I w�� �1��I� IIS IlMIM - EX. MAJOR CONTOUR IF) ZSTA: 0+70.41 EX. MINOR CONTOUR (1') - - - - - - EX. ADJACENT OWNERS --------- N ELEV'. 399.31 - ADDRESS NCDEO EX. ROAD CENTERLINE - 2 EX. CHANNEUSTREAM - K: 49.47 EX. CHANNEUSTREAM BUFFER ADDRESicurc U 2/12/2018 FLM EX. CHAIN UNK FENCE - OHW- OHW- �sSEEN LVC: 100.00 E 113 EX. WATER LINE �,�®III\�. �il��filial►�. �II®.i�ll`ii��ii!� EX. SANITARY SEWER SD EX. STORM SEWER n 11 PROP. LOT LINES ----------- o e uj ow w ----------- PROP. EASEMENT PROP. MAJOR CONTOUR (5') >> > w PROP. MINOR CONTOUR (1') - W - W PROP. WATER LINE EX SANITARY,, SEWER LINE (TYP.) / 365 (S/ZE ANO MATERIAL I / UNKNOWN) /I/ / / PROP. 20' FRANKLIN /I ( COUNTY SANITARY � / I SEWER EASEMENT � I PROP CONCRETE PIER Q STA 7+20.72 (8'x 3' FOOTING) 3 I y I EX SANITARY SEWER MANHOLE TOP = 370.83' INV IN=36252' INV. OUT = 362 23' NOGCEO IN WHOLE GR FLM ENGINEERNIG, INC. 40 20 0 40 SCALE: i INCH = 40 FEET HORIZONTAL SCALE 5+00 STATION ROADWAY PROFILE VIEW 8+00 7+00 8+00 4 2 0 4 SCALE: 1 INCH = 4 FEET VERTICAL SCALE LEGEND EX. PROPERTY LINE + F I EX. RIGHT -OF -WAV - EX. MAJOR CONTOUR IF) ZSTA: 0+70.41 EX. MINOR CONTOUR (1') - - - - - - EX. ADJACENT OWNERS --------- N ELEV'. 399.31 - ADDRESS NCDEO EX. ROAD CENTERLINE - 2 EX. CHANNEUSTREAM - K: 49.47 EX. CHANNEUSTREAM BUFFER ADDRESicurc U 2/12/2018 FLM EX. CHAIN UNK FENCE - OHW- OHW- EX. OVERHEAD ELECTRIC LINE LVC: 100.00 W - EX. WATER LINE - SS - SS EX. SANITARY SEWER - SD - SD EX. STORM SEWER n EX. TREE LINE PROP. LOT LINES ----------- o e uj ow w ----------- PROP. EASEMENT PROP. MAJOR CONTOUR (5') >> > w PROP. MINOR CONTOUR (1') - W - W PROP. WATER LINE -410 -SS -S5 PROP. SANITARY SEWER _ w _ PROP. STORM SEWER DG PROP. GATE VALVE PROP. FIRE HYDRANT ASSEMBLY EX. CENTERLINE-' WITH GATE VALVE AND TEE ---- - ------- GRADE I ^ i MH -1 1 1 4DIA. T -STAO+70.89 RIM:399.04 -^\ INV OUT :392.50 6' SDR35 PVC \ PROP. 17'R STA 1+89.33 3 PI'O \ \\\ CL INV. 390.25' 0448% \ PROP. CENTERLINE GRADE MAINTAIN MINMUM VERTICAL \ SEPARATIONS BETWEEN WATER, \ SEWER "STORM (TYP.) \ (SEE NOTES 1, 2 8 3) 3+27.90 384.00' \ ST C L Ih MH -2 4' DIA STA3+70.89 \ I M R56' .93 INV IN:3791.15 6' SDR35 PVC ^ \\��- EX.MANHOLE INV OUT:378.956' S5 DR3 PVC 2? 4'DIA 7B' STA7+48.09 S \ EX. RI M'. 370.83 SA{.C, INV IN: 362438" CL350 RJ DIP \ PROP. 17' RCP Q EX. INV IN: 382.52 (SIZE 8 MATERIAL UNKNOWN) \ STA 4+57.11 EX. INV OUT. 362.23 (SIZE & MATERIAL UNKNOWN) CL INV. 378.43' PROP. CENTERLINE INVERT \ OF RCP STORM DRAINAGE 3 \V / CULVERT(TVP.) / PROP. 157LFG18. `0 / CL35 STA 5+8273 DIP CLINV.371.21' MH -3 2.18%, / 4' DIA. STA 5+91.00 RIM .375.05 INV IN388.056' SDR35 PVC 1 I INV OUT:365.85 8' CL350 RJ DIP 1 ( � G - PROP. AERIAL CROSSING. ( ) LF OF i6' STEEL CASING PIPE PROP. CONCRETE Q380 ( SUPPORT PIERS TYP.) EX.CHANNEL ee d em I; em O vm i8 m°1 i7 ,e'im $m .p1+im �n mm ^� .^00 w .'9i0+O 010 r- w w W w w LL w I, O i7 w i; O O O i; O i7 O O w i; w w ww Iw w NOGCEO IN WHOLE GR FLM ENGINEERNIG, INC. 40 20 0 40 SCALE: i INCH = 40 FEET HORIZONTAL SCALE 5+00 STATION ROADWAY PROFILE VIEW 8+00 7+00 8+00 4 2 0 4 SCALE: 1 INCH = 4 FEET VERTICAL SCALE LEGEND NOTES 1, SEE UTILITY PLAN (SHEET 05) FOR WATER AND SEWER CONSTRUCTION NOTES. +100 2. SEE UTIUTY PLAN (SHEET C-5) FOR WATER APPURTENANCES, WATER SERVICES AND SEWER SERVICES. 3. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A REPRESENTATION OF ALL UTILITIES WTHIN THE PROJECT AREA. 4. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL -CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING ' WDRK. 5, THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ' ALL UTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EXISTING UTILITIES. 390 6. THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR , THE REPAIR OF ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 7. ALL TOWNHOMES WITHIN 500' RADIUS OF EITHER EXISTING OR PROPOSED FIRE HYDRANTS. < 8. ALL WATER AND SEWER UTILITIES LOCATED WTHIN PUBLIC EASEMENTS TO BE MAINTAINED BY FRANKUN COUNTY PUBLIC UTILITIES. ALL OTHER WATER AND SEWER UTILITIES TO BE PRIVATE AND MAINTAINED BY PRIVATE ENTITY. 380 170 80 m ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER G-4222 EX. PROPERTY LINE - - EX. RIGHT -OF -WAV - EX. MAJOR CONTOUR IF) - - EX. MINOR CONTOUR (1') - - - - - - EX. ADJACENT OWNERS --------- N - EX. EASEMENT - ADDRESS NCDEO EX. ROAD CENTERLINE - 2 EX. CHANNEUSTREAM - COMMENTS 1/2312018 FLM EX. CHANNEUSTREAM BUFFER ADDRESicurc U 2/12/2018 FLM EX. CHAIN UNK FENCE - OHW- OHW- EX. OVERHEAD ELECTRIC LINE - W - W - EX. WATER LINE - SS - SS EX. SANITARY SEWER - SD - SD EX. STORM SEWER EX. TREE LINE PROP. LOT LINES ----------- PROP. SETBACK UNE ----------- PROP. EASEMENT PROP. MAJOR CONTOUR (5') PROP. MINOR CONTOUR (1') - W - W PROP. WATER LINE -410 -SS -S5 PROP. SANITARY SEWER PROP. STORM SEWER DG PROP. GATE VALVE PROP. FIRE HYDRANT ASSEMBLY WITH GATE VALVE AND TEE NOTES 1, SEE UTILITY PLAN (SHEET 05) FOR WATER AND SEWER CONSTRUCTION NOTES. +100 2. SEE UTIUTY PLAN (SHEET C-5) FOR WATER APPURTENANCES, WATER SERVICES AND SEWER SERVICES. 3. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A REPRESENTATION OF ALL UTILITIES WTHIN THE PROJECT AREA. 4. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL -CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING ' WDRK. 5, THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ' ALL UTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EXISTING UTILITIES. 390 6. THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR , THE REPAIR OF ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 7. ALL TOWNHOMES WITHIN 500' RADIUS OF EITHER EXISTING OR PROPOSED FIRE HYDRANTS. < 8. ALL WATER AND SEWER UTILITIES LOCATED WTHIN PUBLIC EASEMENTS TO BE MAINTAINED BY FRANKUN COUNTY PUBLIC UTILITIES. ALL OTHER WATER AND SEWER UTILITIES TO BE PRIVATE AND MAINTAINED BY PRIVATE ENTITY. 380 170 80 m ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER G-4222 ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 40 20 0 40 SCALE: 1 INCH= 40 FEET SCALE ADJUSTMENT IRIS MR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING K IT M NOT INCH ON THIS -.-Al TYOUR.0 ACCORIN-1.1 CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 1*t4vetopment rosswind DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM 4PPROVED BV: FLM PROJECT NO.: 17022 ROADWAY PLAN & PROFILE C-10 SHEET 10 OF 1 REVISION HISTORY REV N DESCRIPTION DATE BY 1 ADDRESS NCDEO COMMENTS 1/12/2018 FLM 2 ADDRESS NCDEO COMMENTS 1/2312018 FLM 3 ADDRESicurc U 2/12/2018 FLM ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION 40 20 0 40 SCALE: 1 INCH= 40 FEET SCALE ADJUSTMENT IRIS MR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING K IT M NOT INCH ON THIS -.-Al TYOUR.0 ACCORIN-1.1 CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 1*t4vetopment rosswind DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM 4PPROVED BV: FLM PROJECT NO.: 17022 ROADWAY PLAN & PROFILE C-10 SHEET 10 OF 1 DOUBLE YELLOW CENTER UNE i 0 395' EX. DRIVEWAY TO _ EX. CURB 8 GUTTER BE CLOSED ,� TO BE REMOVED \ l \ I \ 0 395' I EX DRIVEWAY TO _ EX. CURB 8 GUTTER BE CLOSED \/ TO BE REMOVED \ 10]IH7 THS DRAWING sHAIL NOT W REP - WITHOUT WRITTEN FFRI-ON OF NC HWY 56 (E GREEN S7) 60' PUBLIC RIGHT-OF-WAY 16o' DEPARTURE TAPER (A) PROP. ROAD WIDENING; YELLOW DIAGONALS SEE SHEET C-10 FOR SPACED 35' APART TYPICAL SECTION EX EDGE OF - - - - PAVEMENT(TYP.) _ww OHW L- __ _- SOLID WHITE PROP. STRIPING TO EDGE LINE WHITE MINI TIE IN AND MATCH SKIPS EXISTING (TYP.) I I PROP. VARIABLE WIDTH PUBUC UTILITY EASEMENT PROP. VARIABLE WIDTH V ^P=IVATE UTIUTV EASEMENT EJC EDGE OF _- PAVEMENT(TYP) NC HWY 56 (E GREEN S7) 60' PUBLIC RIGHT-OF-WAY DEPARTURE TAPER (A) PROP. ROAD WIDENING; SEE SHEET C-10 FOR TYPICAL SECTION APPROX. LOCA TIONEX 16'WATERLINE (DEPTH UNKNOWN; CONTRACTOR TO VERIFY LINE LOCATION PRIOR TO START OF CONSTRUCTION) 1501 STORAGE r SOLID WHITE Wry TT 12' Cl,* 150' DECELERATION LENGTH (D) VPAVED SHOULDER SOLID WHITE EDGE LINE - WHITE MINI SKIPS -W -- --- --.-.-..- W w wW� 1'PAVED �r SHOULDER ll OHw, OHW, I 10' X 70' SIGHT TRIANGLE (TYP.) EX. CURB 8 GUTTER TO BE REMOVED PROP. 24" CURB 8 GUTTER (TVP.) I TURN LANE STRIPING PLAN -F APPROX LOCATIONEX 18'WATERUNE (DEPTH UNKNOWN; CONTRACTOR TO VERIFY LINE LOCATION PRIOR TO START OF CONSTRUCTION) 50' STORAGE 106' APPROACH TAPER (34 A) - PROP. 30" CURB EX. PROPERTY LINE - - EX. RIGHT -OF -WAV - - EX. ADJACENT OWNERS MATCH EXISTING EX. EASEMENT POLICY ON STREET AND DRIVEWAY ACCESS", DATED JULY, EX. ROAD CENTERUNE - EX. CHANNEUSTREAM - EX. CHANNEUSTREAM BUFFER 3. ROAD WIDENING 8 TAPER CALCULATIONS BASED ON W=' EX. CHAIN LINK FENCE - OHW OHW- EX. OVERHEAD ELECTRIC LINE W W EX. WATER LINE - SS - SS EX. SANITARY SEWER - SD SD EX. STORM SEWER 5. ROAD WIDENING SHALL INCLUDE 1.5" FULL WIDTH OVERLAY. EX. TREE LINE PROP. LOT LINES -- -- PROP. SETBACK LINE ----------- PROP. EASEMENT 325 PROP. MAJOR CONTOUR (5') 324 PROP. MINOR CONTOUR (1') --- W ------ W - PROP. WATER LINE ----. PROP. ROAD WIDENING 10]IH7 THS DRAWING sHAIL NOT W REP - WITHOUT WRITTEN FFRI-ON OF NC HWY 56 (E GREEN S7) 60' PUBLIC RIGHT-OF-WAY 16o' DEPARTURE TAPER (A) PROP. ROAD WIDENING; YELLOW DIAGONALS SEE SHEET C-10 FOR SPACED 35' APART TYPICAL SECTION EX EDGE OF - - - - PAVEMENT(TYP.) _ww OHW L- __ _- SOLID WHITE PROP. STRIPING TO EDGE LINE WHITE MINI TIE IN AND MATCH SKIPS EXISTING (TYP.) I I PROP. VARIABLE WIDTH PUBUC UTILITY EASEMENT PROP. VARIABLE WIDTH V ^P=IVATE UTIUTV EASEMENT EJC EDGE OF _- PAVEMENT(TYP) NC HWY 56 (E GREEN S7) 60' PUBLIC RIGHT-OF-WAY DEPARTURE TAPER (A) PROP. ROAD WIDENING; SEE SHEET C-10 FOR TYPICAL SECTION APPROX. LOCA TIONEX 16'WATERLINE (DEPTH UNKNOWN; CONTRACTOR TO VERIFY LINE LOCATION PRIOR TO START OF CONSTRUCTION) 1501 STORAGE r SOLID WHITE Wry TT 12' Cl,* 150' DECELERATION LENGTH (D) VPAVED SHOULDER SOLID WHITE EDGE LINE - WHITE MINI SKIPS -W -- --- --.-.-..- W w wW� 1'PAVED �r SHOULDER ll OHw, OHW, I 10' X 70' SIGHT TRIANGLE (TYP.) EX. CURB 8 GUTTER TO BE REMOVED PROP. 24" CURB 8 GUTTER (TVP.) I TURN LANE STRIPING PLAN -F APPROX LOCATIONEX 18'WATERUNE (DEPTH UNKNOWN; CONTRACTOR TO VERIFY LINE LOCATION PRIOR TO START OF CONSTRUCTION) 50' STORAGE 106' APPROACH TAPER (34 A) - PROP. 30" CURB 8. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A WITH NCDOT STANDARDS AND SPECIFICATIONS. 8 GUTTER TO DESCRIPTION DATE BV EXTENT. MATCH EXISTING PROP. STRIPING TO TIE IN POLICY ON STREET AND DRIVEWAY ACCESS", DATED JULY, - AND MATCH EXISTING (TVP.) ONE -CALL -CENTER AT LEAST 48 HOURS PRIOR TO wlY EX EDGE OF 3. ROAD WIDENING 8 TAPER CALCULATIONS BASED ON W=' 10. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS W w PAVEMENT (7YP) - w w 4. ALL ROADWAY MARKERS SHALL BE SNOW PLOWABLE. PERMITTING w 5. ROAD WIDENING SHALL INCLUDE 1.5" FULL WIDTH OVERLAY. FOR THE REPAIR OF ANY EXISTING UTILITIES DAMAGED YELLOW DIAGONALS - - --�_ SPACED 35' APART DOUBLE YELLOW -CENTER LINE -- OHW_ OHW_ t80' - - -- ---ten W-DEPART_URE TAPER (A) I .. 'n-OHW, - OHW_E::E)b - 150' DECELERATION LENGTH (D) V PAVED EXISTING GRADES TO BE SHOULDER EXTENDED AS PART OF ROAD WIDENING 400 - W 399 W W - X400 1. --�_-_ --"-- --�,-- - 12 , PAVED V PAVED SHOULDER I \ W O W� OHW� EXISTING GRADES TO BE EXTENDED 400 I �-i OHw� AS PART OF ROAD WIDENING /� 10' X 70' SIGHT TRIANGLE (TVP.) w� �l� EX. CURB BGUTTER OHW_ I PROP. VARIABLE WIDT1___, _ _ -- - _ - - �� _ TO BE REMOVED -- PUBUC UTILITY EA SE ME NT PROP. 24" - ---- F ­ PROP. VARIABLE WIDTH-�� .X CURBBGUTTER (TVP.) i ----------------- i-� TE UTIUTV EASEMENT i I �\ I I TURN LANE GRADING PLAN NOTES 1. ALL ROADWAYS TO BE CONSTRUCTED IN ACCORDANCE 8. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A WITH NCDOT STANDARDS AND SPECIFICATIONS. REPRESENTATION OF ALL UTIUTIES WATHIN THE PROJECT DESCRIPTION DATE BV EXTENT. 2. ROAD WIDENING AND DIMENSIONS BASED ONNCDOT POLICY ON STREET AND DRIVEWAY ACCESS", DATED JULY, 9. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA 2003, RECOMMENDED TREATMENT FOR TURN LANES FOR ONE -CALL -CENTER AT LEAST 48 HOURS PRIOR TO SYMMETRICAL WIDENING. BEGINNING WORK. 3. ROAD WIDENING 8 TAPER CALCULATIONS BASED ON W=' 10. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS SYMMETRICAL WIDENING, 35 MPH DESIGN SPEED. OF ALL UTIUTIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EXISTING UTIUTIES. 4. ALL ROADWAY MARKERS SHALL BE SNOW PLOWABLE. PERMITTING 11. THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE 5. ROAD WIDENING SHALL INCLUDE 1.5" FULL WIDTH OVERLAY. FOR THE REPAIR OF ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 8. FOR PAVEMENT DETAILS, SEE ROAD WIDENING PAVEMENT SECTION, SHEET 610. 7, 25' BUTT JOINT TO BE INSTALLED AT EACH END OF THE ROAD WIDENING 1 D5' APPROACH TAPER (%B A) ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER 04222 REVISION HISTORY REV 8 GUTTER TO DESCRIPTION DATE BV ADDRESS NCDEO 1/17/2018 FLM COMMENTS 2 ADDRESS NCDEO COMMENTS 1/23/2018 FLM ADDRESS FCPU 3 COMMENTS 2/12/2018 FLM ORIGINAL PLAN SIZE: 24" X 35" PROP. 30" CURB 8 GUTTER TO MATCH EXISTING -- — — ISSUED FOR 398 w w EX. EDGE OF w W PAVEMENT(TYP.) _ _ PERMITTING w W DO NOT USE FOR CONSTRUCTION W. - 20 10 0 20 _-----�--..� 38X• SCALE. 1INCH= 20 FEET ----. ` N SCALE ADJUSTMENT -398 _ THIS BAP Is 1 INCH IN LENGTH ON OPIGINAL DRAWING EXISTING GRADES TO BE -"- I } - EXTENDED AS PART OF 160• ROAD WIDENING IF IT IB NOT 1 INCH ON THIS SHEET.ADNSTY �Fw.. "' �TF-DEPARTURE TAPER I.) - SCALE ACC—GLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 00 rosswind ��j Development DATE: 12-07-2D17 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 ROAD WIDENING PLAN C-11 SHEET 11 OF 17 Anow,r ,y�+ eeupani PLAN f CROSS SECTI ON GRAVEL CONSTRUCTION ENTRANCE NO SCALE BAFFLE INSTALLATION -STEP1 BAFFLE INSTALLATION -STEP2 BAFFLE INSTALLATION NO SCALE BE AND T TON BARREL nPEINNER POL T I NO OF THE THE 1— OT IHE A BE TEA N L�7 T TOP HEA THE lFDARiFFAK eECURE rHE uPPm EocE AxoA— TV THE EPPER RF_ I TEM ¢ HE ONFORITIONILETAN.LTEETE.N11, 0 ON BE DANACEAL .LA BSTCMl AD sTAeIuzED CUT INST NAE EI AND AND LE REIANExT SMDDTT THE AREA TO BLINDYATx THE ADA'R ABus =N_ DM VLUwNxD A.,H NF 1 SKIMMER SEDIMENT BASIN NO SCALE � 00019 .�rvF ER MATswDF.T _ DoMj1` 1. DESIGN OF END—SECTION SHALL CONFORM TO STANDARD REINFORCED SECTKINAL CONCRETE CULVERT PIPE AA's 2. ANY TWIN BARREL SYSlE1 ATM THAN 6 42RCP REWIRES A HEADWALL i 3. ANY SYSTEM OF MORE THAN 2 PIPES REOURES AHF,L 4. SFE NCDOT "ROADWAY STANDARD DRANINGS' FOR IEADWMI. CONSTRUCTION DETAILS. FRONTVIEW yFs RE WRE FENCE NAL 111 STEEL NGBUSED RAISE ILT 1UNCE ILURES. No 57 VS—M DT G EQR G E TFA—AN T�=�. I—EILL GrcH BARrv. DA. A B C vROPFRIr sTANI¢Fn x� LY BEEN 16? 64—EL1 SIDE VIEW ROT E0Sr�CNEEDS T1 BE RiAxDT xED,N� A G E R¢ REABa¢DN¢EN ¢A EOF�FLARED END SECTION OFI TURNED UPHILL. NO SCALE 3 NSPECT SILT FENCES AT LEAST ONCE A WESK AND AFTER EACH RAAF NNRE ANY REQUIRED FEE—IMMEDUGELY. I RENOVE SEDIM It DEPOSITS AS NICESSARY TO MOVIE ADEQUATE ITORAGE VOLUME FOR THE NEXT IIUN AND TO NEELICE PRESSIRE 01 THE FENCE, -F CARE TD AVOID INIE11IN116 THE FENCE 11ING CLEANOUT SILT FENCE QNO SCALE _ e 1i=ir.RM0. r :D li&1f.=�C= TEMPORARY DIVERSION DITCH NO SCALE SIDE VIEW AETOR PST -1—L. LILTHE sOF TxE FRONT VIEW aTE =T�PIT'ECTn=L INE RE =DEIRVD­NT.��CENULAT.�D R DAMS FLOW BEWIn BE MUMUN.T R—. TT—TION Am rna,ND v�DIm DEc wx 4Ox HDIET AND— STEPSEQUENCE .01M , HEIGHT.WDTIDFTER INED1EXI--11—RAII-1SEDIL,ENTBTGRAGEREWIRED 2 KEV RIP RAP INTO TIE DAM FOR STA&uZATION ROCK CHECK DAM NO SCALE LENGTH (LB) INSPECT PIPE INLET PROTECTION AT LEAS AFTER EACH SIGNIFICANT (TO INCH OR GREATER) EVENT TO SEE IF ANY EROSION AROUND OTR BELMTHTM E IMMEDIATELY -EAU. NE.T.NES HAVE BEE==REDED REPAIRS TO PREVENT FURTHER LVAUGE SECTION FILTER BLANKET OUTLET DD JDD lA W RIP RAP 4 FES, 2f S 12 S CUSS a'BM,XP 2i _FE 52 1S S]5 S 0.T5 CLASS RIRUP S INERAID IS I STS 7S f GA50 B RIPRAP 2Y RIP RAP ENERGY DISSIPATOR NO SCALE EVC EX. PPE vuc TeT luso AVDF Frc nFE �TEE onxx.F.uTF END VIEW FRONT VIEW ED..FmxF.,a,E.O ME IF xe PERSPECTIVE VIEW Y..TDRRnRy— REF�,IDMx¢,HF11ER BNMERTD�rETHEREG SKIMMER NO SCALE PLAN VIEW To AS E IS I M ttEMKHR TxEFSOA D' SIDE VIEW "" DDRADF II THF wADA.AE --� MAR..,MRnLTARAP. I— HLTFR FF,A FRONT VIEW OINENT LEME I AS NECTESARY TO PROVIDE ADEQUATE STORADE VOLEME FIR TIE NEXT EARN ANI TO REDLCE 3. RE E ALL 1- FENCE OUTLET MATEELLI AND UNSTABLE 8ENIENT DEPOSITS AND -NR � AREA TO IRADE AND ETA­IZF SILT FENCE OUTLET NO SCAL PAD CLAMPS NON -WOVEN GEOTEXTILE FILTER BAG I PUMP WELL VEGETATED OR OTHERWISE STABILIZED AREA CLAMPS FILTER BAG C FLOATING i \ INTAKE GRAVEL PAD' PUMPJ I. FILTER BAGS MAY BE USED TO FILTER WATER PUMPED FROM EXCAVATIONS PRIOR M DE CHANGING. FILTER BAGS SHALL BE FADE FROM NCN-WOVEN GEOTEXTILE MATERIAL SEWN WITH HIGH STRENGTH, DOUBLE STITGIED'X TYPE SEAMS. THEY SHALL 8E CAPABLE OF TRAPPING PMTICUS LARGER TIWR 150 MCROH5. THE PUMPING RATE SINLL BE HO GREATER THAN TSOGPM OR yR TIIE MA%IMM SPEGFIED BY TIRE MANUFACTURER, WHICHEVERIS LE55. PUMFIMAKES SHOIAD BE FLOATING AID SCREENED. FILTER MOS SHALL BE LOCATED IN WELL -VEGETATED (GRASSY) AREAL AND DISC N ED ONTO STABLE, EROBON RESISTANTMEAS. WHERE THS IS NOT POSSIBLE, A GEOTEXTILE FLOW PATH SHALLSE FRONDED. BAGS SHALLNOT BE PLACED ON SLOPES GREATER THMN 5%, THE PUMP DISCHARGE HOSE SHALL BE INSERTED INTO THE FILTER BAG IN THE HANDER SPECIFIED BY THE MANUFACTURER AND SECURELY CLAMPED. A SUTAB.E MEANS OF ACCESSING THE BAG WITH MACHINERY REQUIRED FOR DEPOSAL PURPOSES MUST BE PROVIDED, FILTER BAGS SHALL BE REPLACED WHEN THEY MOXWE X FULL SPARE REPLACEMENT BAGS SHALL BE KEPT AVAILABLE FOR REPLACEMENT OF THOSE THAT HAVE FAILED MARE X FULL. FILTER BAGS SHALL BE INSPECTED ONLY. IF ANY PROBLEM IS DETECTED, PUMPING SIMLL CEASE IMMEDIATELY MD NOT RESUME UNTIL THE PROBLEM IS CORRECTED. SILT BAG NO SCALE ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 91 9`610 1051 FIRM NC LICENSE NUMBER 04222 REVISION HISTORY REV DESCRIPTION DATE BY 1 ADDRESS NCDEQ 1(122018 FLM COMMENTS 2 ADDRESS NCDEQ 1232018 FLM COMMENTS ADDRESSFCPU 3 ,,.. 2/12/2018 FLM ORIGINAL PLAN SIZE: 24"X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS BAR IS I INCH IN LENGTH ON ORIGINAL DRAWING 0 1� IF IT M NOT , INCH ON THIS SHEET. UST YOUR SCALE GORC!%iLY CONSTRUCTION PLANS CRAWFORDTOWNES NC HWY 56 FRANKLINTON, NC 27525 z Crosswind r% Development DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 DETAILS C-13 SHEET 13 OF 17 FOR SHOULDERS, SIDE DITCHES, SLOPES (MAX 3:1): BRUIII RYE AW 15 TALL —LE I Pro USEVAGRE 2E1 ­ A BRO—GRE nCSIREGRE FtcI,LuL MFEssu ILL coUnEN, ,W ,s uFECUE ANGWM"'T,IRPOV.»GRMLLErHsl.vs 3 OR SORCHU.es TRE �ouPTWT�l:XR ZAoGBEFGRNE D� lwl MIXTURE ACRE P TONNE Sats, suPERPHosPHATE500 LGNMCFHEANALYSIS StRAVV ANCHOR =A&UNULSON AT WO xox FOR LATE WANTER AND EARLY SPRING: s �L IRE NpNNUAL v�n'ixRRE IN wEDMO PAPS FEET 1111 FOR ...A. ILL r 4sRNACREXE .0 I A RATE OF NT LEAGRE GLASTAL ALAN AP'RS 'IGS, 11 FELT — REDGM.E.DATIONG OF SOIL TESTS OR LIMESTONE Allo L�SIACaE,RUO11io ar ERN � v MULc". _SNE NG ONAMRLGHANOHGNINGTGGL REFERTLOE IF .—H . FOR FALL. ERA^• EMs RVE MM) ,pL»ACRE uM°NNs,GN�Re:No40pwsoo�'`n`v` E`�ROc"oo Ee'Rm a gRAL ­ T�aNO MDED AGO = DR. NEFFAS.-AMULTHAMILHORSNOTOOL REPAl All REFEAR L" sEvaNGr.,rLOVER (RmM[NJ uile°E_=A OaGSE EANLY SEEDBED PREPARLT11OR 1 CHISEL O ACTED AREAS AND SPREAD TOPSOIL THREE INCHES DEEP DYER ADVERSE SOIL CON -1 rc - s, LESPE,xumu a MANLn AVILA S NOT- -ILY"'EAGODARING. 3 RREMOVE AL IP THE ENTIREoosE RacN RmrsEANo orHw oe ..,,HFACE REnsonnRLr sMooTH AN.'EXTU PH,"PARATErm� Lis UNIFOR. ANDINGONFORALF—THETCe" :�'Es OF SOL 4. AFL AGRICULTURAL LIME, FERTILaw AN SUCEEPHOSPHATE UNIFORMLY AND Mix—Sou EEe¢ovn IS. LIMED. oFsaN HE. NOT BE wcHER 5 =LI UNTIL A —PULVERIZELL FIRM REAGOIAGLY UNIFORM SEEDGED IS PREPARED FOUR 10 SIX 1ENT­ SAGE—IDAHONNAT,NGREGILTESTE ENTHEAE=FOGA11A11LYA DIE GRADE T'EL=AT7­PEEUVXGRE GETHEERTUMNIIIE AS AAXR,FNA­ ,%%`E R SEEDON ESHLl PN REDSEED ANDCOVERSEEDLIGHTLYVATHSffOwG to Er DRCULllAC—EN ss MINGTESEFGNE—GATxxI. csEEDERISLIsm,muor Mlx sEm Ano FERnLaw MGaE THan UND ULCH IGH A REEaNGR,T�DAREAEANOM NrCE�aYR ARS OR REAREDINDT,MTHINTHEPL HNGEEAElH D SHOULD BE NIADINAGED RE ESTARLISH FOLLOVVNG THE ORIGINAL LIME ER ND THEDONTODNREREREEEEDRONING, ON N.,PRGuI& GE FORE „RROMN ETMEaERT H.,ON BLE PPLYAGNI—RALLIMEMGNEITON»AGNEMINIMUM ORPER BOILTEST TEMPORARY SEEDING SCHEDULE TB®TRRGLw RE supea MULCH ons EmekEs�smnvFr .—S NO SCALE ANCHOR LT o mG GA—RE ON EMULSIFIED ASPHALT a=GALsncRE PERMANENT SEEDING SCHEDULE NO SCALE D M�y'ft_w H:T.=IH'Mi'111111111111 mmm l l •Y•. at •, 1• f —L--Z=-MF --- TERN. E GRAVFILTER-- —I —1. T- J OVEULDVAIDDIURS 11 1EEDED GIVE L- .=N, 1. SuMEREGEN, A— E, Z =RFULTV FIT NAIRDAVARE D-- ON COMPARABLE RE ME. T. To ING. .—,No. ALL BLOCK OPEA­ TO HOLD GRAVEL IN ­ ARJENDED A IF ONLY STONE AN ARGUNRI TIE INLET TO IA 1AFOOT-DE LIEL STONE ARIA AetTwiEN INLET FROM IN FOOT USE H v.INCH GaAVG¢INcnoin5]wATHEO MGNq nor ARM,�McxNE5o50FHt auo ARRL�SN AT LEA AMT L1 VEEXAND AFTER EACH SIGNIFICANT Ix INC. OR GREATER, EGessARv TO PROVIDE ADLowrE STGRAGE VOwME FOR sueSS"ENT PING AGEDLIATELYMABLIZm REMOVEALL 'HE C,E�Ga� ENER HA RR�EALLRAREAE OOTH�No OMPACT°F,PER�,. SING BLOCK AND GRAVEL INLET PROTECTION NO SCALE ROLLMAX" � � ROLLMAX" Spec'f cat on Sheet EroNet' 575° Erosion Control Blanket 1 aEAT�amTes,Na 001"m Tersest NE RTHANURIK HTAFEN' MATTING TO BE INSTALLED PER PLAN NOTES. 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL -OSE ED DO NOT SEED PREPARED AREA CELL -0 -SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE SLOPE By ANCHORING THE BLANKET IN A6' (15 CM) DEEP XS' (15 CM) WIDE TRENCH WITH APPROXIMATELY 1T' (30—) OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH ROW OF STAPLESISTAKES APPROXIMATELY 1T (30 CM) APART IN THE BOTTOM OF THE TRENCH, BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING I2'(30CM) PORTION OF BLANKET BACK OVER SEED AND COMPACTEDSOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLESISTAK ES SPACED APPROXIMATELY 1T (30 CM) APART ACROSS THE WIDTH OF THE BLANKET. 3, ROLL THE BLANKETS(A)DOWN OR B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM . STAPLESISTAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4, THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2' - S (5 CM - 12.5 CM) OVERLAP DEPENDING ON BLANKET TYPE. 5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3' (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA APPROXIMATELY 12' (30 CM) APART ACROSS ENTIRE BLANKET WIDTH. NOTE. 9N LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6' (15 CM) MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. DETAIL AND LANGUAGE PROVIDED BY NORTH AMERICAN GREEN REV. 1II SLOPE INSTALLATION NO SCALE SECTION THRU BASIN, FILTER AND CULVERT PIPE NOTES: 1. CLEAR THE AREA OF ALL DEBRIS THAT MIGHT HINDER EXCAVATION AND DISPOSAL OF SPOIL. 2. INSTALL THE CLASS B OR CLASS I RIPRAP IN A SEMI -CIRCLE AROUND THE PIPE INLET. THE STONE SHOULD BE BUILT UP HIGHER ON EACH END WHERE IT TIES INTO THE EMBANKMENT. THE MINIMUM CREST WIDTH OF THE RIPRAP SHOULD BE 3 FEET, WITH A MINIMUM BOTTOM WIDTH OF 11 FEET. THE MINIMUM HEIGHT SHOULD BE 2 FEET, BUT ALSO 1 FOOT LOWER THAN THE SHOULDER OF THE EMBANKMENT OR DIVERSIONS. 3. A 1 FOOT THICK LAYER OF NC DOT k5 OR #57 STONE SHOULD BE PLACED ON THE OUTSIDE SLOPE OF THE RIPRAP. 4. THE SEDIMENT STORAGE AREA SHOULD BE EXCAVATED AROUND THE OUTSIDE OF THE STONE HORSESHOE 18 INCHES BELOW NATURAL GRADE. 5. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, FILL DEPRESSION AND ESTABLISH FINAL GRADING ELEVATIONS, COMPACT AREA PROPERLY, AND STABILIZE WITH GROUND COVER. HORSESHOE ROCK PIPE INLET PROTECTION NO SCALE Specification Sheet - VMax' SC250` Turf Reinforcement Mat NORTH AMERICAN GREEN S75 NORTH AMERICAN GREEN SC250 EROSION CONTROL BLANKET NO SCALE EROSION CONTROL BLANKET NO SCALE 1 11—eiiR®�E 10' x 10' SQUARE WASHOUT PIT I \\ 24" MIN. �/ I MAINTENANCEINSTALLATION NOTES: 1. INSTALL CONCRETE WASHOUT PIT AT LOCATION(S) SHOWN ON PLANS. 2. LINE PIT WITH IMPERVIOUS FABRIC OR POLYETHYLENE SHEET. ANCHOR FABRIC INTO GROUND OUTSIDE PIT AS SHOWN. 3, ALLOW WATER TO EVAPORATE COMPLETELY PRIOR TO EXCAVATING PIT. 4. WASHOUT PIT MAY BE LOCATED NO CLOSER THAN 50' TO DRAINS, INLETS, OR SURFACE WATERS. 5. MAXIMUM WATER AND SEDIMENT DEPTH IS 1T'. PIT MUST BE EXCAVATED AND RE -LINED WHEN DEPTH OF SEDIMENT REACHES IT OR COMBINED WATER/SEDIMENT DEPTH EXCEEDS 12' FOLLOWING WASHOUT OF CONCRETE TRUCK 6. REMOVE AND DISPOSE OF HARDENED CONCRETE AND RETURN THE STRUCTURE TO A FUNCTIONAL CONDITION AFTER REACHING 75% CAPACITY. 7. INSPECT CONCRETE WASHOUT STRUCTURES FOR DAMAGE AND MAINTAIN FOR EFFECTIVENESS. 8, REMOVE THE CONCRETE WASHOUT STRUCTURES AND SIGN UPON PROJECT COMPLETION. GRADE THE EARTH MATERIAL TO MATCH THE EXISTING CONTOURS AND PERMANENTLY SEED AND MULCH AREA CONCRETE WASHOUT PIT 1 A NO SCALE ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C4222 REVISION HISTORY REV NDESCRIPTION DATE BY 1 ADDRESS NCDEO 1/12/2018 FLM COMMENTS 2 ADDRESS NCDEQ 1/23/2018 FLM COMMENTS 3 ADDRESS FCPU yi2/2018 FLM ORIGINAL PLAN SIZE: 24" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRANMNG IF ITISNOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 Crosswind evelo men S p 2 DATE: N-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM DETAILS C-14 SHEET 14 OF 17 FRONT ELEVATION SECTION r RADIUS B,, t RA 1 I N r 3 RADIUS lr ]"RADIUS JLJOINT I 2-0" STANDARD CURB AND GUTTER I NOTES: 1. CONCRETE SHALL BE 3000 PSI. 2. CONTRACTION JOINTS SHALL BE SPACED AT 10' INTERVALS OR 15 INTERVALS WHEN A MACHINE IS USED. 3. EXPANSION JOINTS SHALL BE SPACED AT 50• INTERVALS. 4. FINISH ALL CONCRETE WITH CURING COMPOUND. 5. FOLLOW ALL APPLICABLE ACI REQUIRMENTS. 6. TILT GUTTER TO MATCH DIRECTION OF DRAINAGE. CONCRETE CURB AND GUTTER NO SCALE yr/A. I/A- I ,Y/Ai...�..+•r'�� r/rr —1 -- NCDOT DRIVEWAY TURNOUT GRADES (SHOULDER SECTION) NO SCALE 2" NCOOT TYPE SF -9.5A BITUMINOUS SURFACE COURSE COMPACTED SUBGRADE 8" NCDOT TYPE ABC, AGGREGATE BASE COURSE NOTE: PAVEMENT SECTION SUBJECT TO CONFIRMATION AND APPROVAL BY GEOTECNICAL ENGINEER PRIOR TO CONSTRUCTION DRIVEWAY PAVEMENT SECTION NO SCALE GRASSED UTILITY STRIP —E. SIOEWNX (CONCRETE 300 P.S.IJ Ilk ARIES DOYhT �IS' CURB ACTED TO A GENS TY 'I ANO GUTTER NO LESS THAN 95% TYPICAL SECTION 31 �I rclL g I_ JOINT FILLER SIDEWAL(SURFACE I %RADUS I TRANSVERSE EXPANSION JOINT PLAN VIEW NOTES: 1. TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF SO FEET. 2. ALL CONCRETE TO BE FINISHED WITH CURING COMPOUND. 3. A 6INCH DEPTH IS REQUIRED AT LOCATIONS OF DRIVEWAY CROSSINGS, AT STREET INTERSECTIONS (ALONG THE LENGTH OF RADIUS CURB RETURNS), AND IN THE HANDICAP RAMPS. CONCRETE SIDEWALK NO SCALE N a �t el rrnRr �LWEN MA12 rrtLNC�+ 61t: Nnls •r LA •°� k o- s.°w;s•.�mrox>s x w,.rN„ N a%xsn ' FRANKLIN COUNTY PUBLIC UTILITIES SOT —SANITARY SANITARY SEWER MAIN 3-1 TRENCH DETAIL 0 c c rfn p C��9N S�D9m ZyGT FRONT VIEW L TBROOMR SN -INC EASE TO3'MIN. 30' —ill VAN -ACCESSIBLE io ACCE'aSfY[. SIGN AT VAN Ba" WHEN PEDESTRIAN 4'souD P G OPADUE ENCLOSURE DOOR; INSTALL SUPPORT WHEEL AT BASE AS NECESSARY TO BE COMPATIBLE WITH THE BUILDING IN TERMS OF TEXTURE,.—ITY, MATERLAL. ANO COLOR) = SPACE ONLY MIN. HEIGHT B (MUST B' RESERVED R7-8 OT R7 -8B SCREEN DUMPBTER FROM VIM) CONCRETE N 2B MYS PARKING GREEN a'ABc —(SEE 6 c� rY SPLIT FACE CMU OR BRICK WALL (TO BE COMPACTED SUBGRADE p BLUE SLAB SECTION ADA SIGN AND POST DUMPSTER SLAB AND ENCLOSURE DSCALE COMPATIBLE MH THE BUILDING IN TERMS OF TEXTURE OWHTY, MATERWL ANO COLOR) ®YUNAU­l e "e. .NA a.sr ,H a oL a u. WHITE SYMBOL arMmuL AT NU- •.o _ ,raLvvac Fuurrcormr �wrx zprt or vHe —ILL. AATPUAL Ur o«`wrex,a m Am N,wu...0 r"` I AALLWIT.CT, 'r" ®m41 AM11 K PAn,m 300.01 WHITE BACKGROUND HEAD DUTY HINGES MAXIMUM TM P f2W R7-8D CONSTRUCT MIN. IYX 12UNITER CENTERED DESURE WALL TO FROST DEI FROST PTH TO PREVENT FROST HEAVE 1A ON CCRETE SLAB (SEE SUPPORT SECTION) WHEEL I 0 c c rfn p C��9N S�D9m ZyGT FRONT VIEW L TBROOMR SN -INC EASE TO3'MIN. 30' —ill I NO.<REM 12' —E.E0. L O.G E. W. Ba" WHEN PEDESTRIAN 4'souD P G T PATH FROM - 3 = Z O C, ,o. a HuT mr ,� �, CAR TO WALK B' PASSES BY OR UNDER SIGN. CT H a Iwo PSI CONCRETE N 2B MYS S. SPUD FACE GNU OR BRICK WALL/TO SIDEVIEW BE COMPATIBLE WITH THE BUILDING IN CONCRETE a'ABc —(SEE 6 c� TERMS OTTEXTURE.G A ITY, SECTION] MATERIAL AND COLOR) COMPACTED SUBGRADE Z D0 SLAB SECTION ADA SIGN AND POST DUMPSTER SLAB AND ENCLOSURE DSCALE NO SCALE 0 c c rfn p C��9N S�D9m ZyGT ,a s E,.r Tn of r,LL _M` FTU omrxP ..ra �_ x eu.o u,E . ..a.•a. _. —_ __ � __—_ ..a.•. r --- _ . ._r . ..a — — - IA- Q Z¢p �QQ4 AjaZ` y� `31 q�-LLOJ Ol o`A„",xsRC mr .Lrr Twx . •v r - s) `.0 -v r..IN 1 ADDRESS NCDEQ FLM `•. NORMAL EARTH FOUNDATION mix ROCK FWNDATI PIPE W @ N TRENCH ITARLIE MATERIAL FOUDATION 3 = Z O C, ,o. a HuT mr ,� �, Z M ADDRESS FCPU 3 CT H A ,F HTim mT r v Hs NrAn m9��"',:. r . e.o ".• _' �m °rs, "' m, LLxr aPa e o o • r ;� 6 c� y f r z nu NORMAL EARTH FOUNDATION ROCK FOUNDATIONtuas P P V lN9UITABLE WTFAIAL FpI1DATI0N Z D0 °°XOexov°`ML O y s .. .MHnu, I— z S W ®YUNAU­l e "e. .NA a.sr ,H a oL a u. arMmuL AT NU- •.o _ ,raLvvac Fuurrcormr �wrx zprt or vHe —ILL. AATPUAL Ur o«`wrex,a m Am N,wu...0 r"` I AALLWIT.CT, 'r" ®m41 AM11 K PAn,m 300.01 300.01 a REV SCALE: N m 1 ADDRESS NCDEQ FLM `•. 4 ADDRESS NCDEQ 1/23/2018 FLM COMMENTS ADDRESS FCPU 3 8 M 5 a FRANKLIN COUNTY PUBLIC UTILITIES -KA-M l SEWER SERVK:E CONN 014 S-5 WITH CLEAN OUT DETAIL (NEW INSTALLATION) A4 L s �;.rgria _p rFRANKLIN COUNTY PUBLIC UTILITIES S-111 MANHOLE COVER DETAIL TYPICALWC WATFI VNVE STYLFS: TArwArER .wax pan/ ✓uvEA N TALIn11oNs: H------- T -- B Am s<Rrer� xEw Lw e, -P, TYPICAL SANITARY SEWER SERVICE BACK -DATER VAIVF INSTA eTON +., FRANKLIN COUNTY PUBLIC UTILITIES oRA1wq� TYPICAL SEWER SERVICE BACK -WATER VALVE S$ INSTALLATION DETAJL -- a A- A - �,, 9•w� .o x L �x 'Ws iSOM 1Rr( V! W 0+ [r P STRUCTURE STEP DETAIL FRANKLIN COUNTY PUBLIC UTILITIES S-14 I STRUCTURE STEP DETAIL E tENTR CONE I P MP tT A PRECAST MANHOjF DFTA' FRANKLIN COUNTY PUBLIC UTILITIES Lmwiw� S-7 PRECAST MANHOLE DETAIL SOLVEx+ CCKR, [a^5S\ /l x. - n a_5. S,fUS N I,r /�-�a Tar awc I r I STe vNINr• SfMxl'� T.. � I I LI a" ^EPVi_' fv T V J TC f,X1571ACs�p N� f'ke� MM�~•'� x PLn. LL a_ sw , _„xc mn f FRANKLIN COUNTY PUBLIC UTIUTIE II CONNECTION j S-15 TO EXISTING OR NEW _ PRECAST MANHOLE ENGINEERING POST OFFICE BOX 91727 RALEIGH. NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER 04222 REVISION HISTORY REV SCALE: N DESCRIPTION DATE BY 1 ADDRESS NCDEQ FLM COMMENTS 1/12/2018 FLM 2 ADDRESS NCDEQ 1/23/2018 FLM COMMENTS ADDRESS FCPU 3 COMMENTS 2/12/2018 FLM ORIGINAL PLAN SIZE: 24” X 36' ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL ORAWING I IF IT M NOT 11NCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 Crosswind Development DATE: 12-07-2017 SCALE: ASSHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NQ.: 17022 DETAILS C-15 SHEET 15 OF 17 GENERAL NO76: 1. wLwleaN.sun®«+IeQocrravals swumlQawlro MwncnaAaee:mnb M TY ar rAJeCM nqc Nllllp nAlneDp, ulGm MORD aDRIQ W e 1RRN 2. O AMI1R ND nnXI®91 VlL mIMf Q eOnm RIILQ Afd NO llLem RIIDQ eA1e«ed11LeMC WLo1 NIL[ DIC.TILLbM IOdIxGMY.en] AK xlenR:f/eea. can Idt R91QMm JON15 s Arr11 W 1Ie1 ]nNL a1nmA ro Ala e 1 ez MnrYm rR AIn mrMreswuanlsaw«I«aleMeJOQTISa WIINLTQ®aAWriMI asr Imx rrt m.:1RI1d AS WLneGlne) au6rR, slMaDaa WarrcTlA®aaJ1x, ediiOG« SMM4«M WbAtflGlm IXG1RM AT nbIICTJ. «R]IM1 ]. NORR IRl000}SMNLMA]IWM� ml[ill[ Gb/Im!MT MIN. NC091 MOIxN ]IIY � I MOC µ1GImEl01aA WTaNe Wq.OAe e1U1 mllmrt. R • I.R mrDRle a1NL Mmv«m aroma, wAm mNee AmaAre, rQR�ATe AKAx. dsllf 51LY1 Mme M «I MAOOaRVNLt Md AOIx Clxi. WemaRm�aeld IUAu rr[ AIo calls ALYRGID ]nNL (dgeA ro Am cv. mARS[ ALCRGR snAu M SR 4r. 51 «L7, xl A)II'IIro OAYT M1YASn WYM SINrDIdCD Ia AM mW AxOMOr CCEIf IX •mnurroltsa 4. ALLelmm mRulQmxwswuMDw.a®ew. s. arxenovaReRDRJrz;elensMAumxn>alroAsn ranauMaAwswuMrv�x Arrwul¢wm+eralee®rrAdn I«nAacRMQpRdcexe•umrmncN a PuaelmaMIII. eROMORdK Qarnlne. satoaVllaDADevmxcwlaroM naxaloleaArJele-euaxcmxl®Inmalet«Imwo mmnomr. c xerlef MAec rAm swLM NatDadM n¢vlamuDur Ie. Ion vRu1 rdlmr, wm olznlcrR111A1ccs- xi 7. ncsNLM ]dltluxsla MI aDs nCxolwLmMaY roll lewmaov Asa ASL rACSwua olav<+1 ro tMrOn Qm11®romdx Av uTwnzwlLcvrorca IA]r I[S]111W TMOTeC M o61r 1 uwxta]omre. rM�slwL reelNle AxxNN arnrlml IMI xroulDeils®Saa. x DQNrc na A1RIIeD ARRdtfl all efem]wuMlaSm KD®IM1W QMrtLDIIOf aHY®.flDpplIXIXM a41mLrLD]IWLM TOImro mtle�e M uTYd' LVILTROIM Hes. M1R1110DRIaD lesxealru mIOW ro ATM 01 IH AMDMMORTI CAed1MlrAR edOQILCOR weR nCAaesosm, IIG ] Wll M rNllm AM9dt mAlm x ICQ.Y9VIR MIX M OR ]Ia1Gi106. nz surraamrrel S OKSISL SIi a.VDI AMD MORe O<eJelIM1RLTDI bJNSU1C �� WiIC1e,M Imlv+mnrtM1nlfd SIQaI1 WQIOIp Fa HORN dlR0 bg1lO mI4'ilRICr.4 •SOK LLII AMD MOR] A AT eNaDKM M NMI- SIm GnXx rR sa nc}1: Gaal TYPICAL C 51MG PIPE PUICi 2 ADDRESS NCOEO -3 a®cduJQn «naaonxx eDMawNM Ragam Jdxr aTxm alxml uvaezD Sa oKsle Ib Alf�Je TIA09MS11LY1 M NDT6: M I. bRYI«SU]R n016110XS1YY1M Qwblb RNx ADOYMe sAx /GLaLNe!MlDlearoxe1L01MIRRm GMdNA OeYgMenar T)NErdOArgXS9rAxOIM SrepnGllelG .. M15R gClQiR«IRa1Ero 1«dlretTf[, nJtllf Aex oJ]�nrfeswLMx]fAum unmliz l«RYIDAID exa'e. bR0 MWL NIRI OISMMIW rteID6lxeRGtC IQJOMd[fOROXd Mrte JdeldGDt IN RIM eDINMeIUAIm 5lMbr dpS. OiNAfLOFAVIQ E. eH.01 O M N«M C,FWxA pPAMlxeO Q N— TQNlY01RAlgNS naOwArsrxcwm dAMrlm•. sulrpRrTne ra nvs srvuM mealrm a elGrm eneodl YDGRIDe mlGnoB AT SM. ]a OWANK }I4 r. r«sndrnr rArAxeme5lavrn Tfe d rdAaid. C Iz gDARSArJa.10 W+1 reRelRtM IDdxgM 4 N � _ p L alorzl NOM: I. fdYrMblCOIeG'JIILL MM1a 091[IdOr mxof 1e inc5 Kn Imlr d i lar «ICI u rac DRNM6111. z. xdlauxdmursvuM amxawM D1alD do.ni m W�ln: w,,,eulw 71! w wsM euoea, «muv. vAQG rwxRezerxvsrm Rwx �' MacaxxaaeurswuM !d CO M Wra WILY 1R SMll WLIOIGM 7Q ATMOmiAae M NMI- °O"I�a"f"'^s , )IYa ARt R11[e.S, «L111VL Gaal TYPICAL C 51MG PIPE PUICi 2 ADDRESS NCOEO -3 a®cduJQn «naaonxx YI' Ragam Jdxr aTxm alxml uvaezD ADO/7IeIL 9PNb RIRSim C/81MG PRC raWnmx mlo¢rt rel OOIIOM OI C)IDl S6 DK 114 «nOOD rwx tAAJDI (ISLIi WWI rfe,or rQCsm wnrle ADOYMe sAx ONCIM OW[IR M1MLTxT1df Ru aJ exJ �] NDT[„j; Ism art wuMenelslwrAsm«9tm1n L 140.!)SO SVAL><6YdAWYYTeDeRaGIM Lf b,00D e IL 0.1)50 10 ID 0.1)50 IS xi P51. PAxDxa AIDINf aWlM Ae IeI�IXMLMd QAIBOI rINJC UINp nAMDeO« IQ 30 OJnO 14 Y 0DDDAisnrTnaAo xi R. OUCLL ]Yx ILR sIwLMsn«1mwd NOseea AAIreIpiuA[RA1uUasJKarmx«lRswTxm ASMeIt V5zpl1i.M1lONeWsML rt14 uMn& ecaMTs xiuY< mm:�»: rMoroenmpDRGss. .IIu]NsdaIRNtm z1lDee acC9TvlQxWlNxt«wr1t®«lrdsuIJuNTOneHl0xL M % Q1515 CS Id151 ' IR IIRAttIRa I«eV]IMi d'IOANSTerI. w Y asrrs u �0''tN16wsr«s.�menAmKalmmw. 4. e0rrouar Aero MATAWYYMrrDdRMu z 4e a]m 4Q z a]Om a c5 SdJlnaao eevAilpM. rllDiiR II.VIC51e'I aroasYMeenml GMImIrRA1D GQdlI, rwxRezerxvsrm Rwx �' MacaxxaaeurswuM xaAxrADATIOxeIo Q CASMORRAMD Ip � LIpDKrwMDlaa amaamlmsros ATORYL MYf Sidi e1111NMIAerJC °O"I�a"f"'^s , )IYa ARt R11[e.S, «L111VL FLM TYPICAL C 51MG PIPE PUICi uJsle;rrt ]!`SIe1 MR,M sex sna MR M Se'eA]Qe DIT GaQlirse 3NI V. xcux A WYM OII sme reudenAm dR IC4eM OrM IRICMTIL61n x neM I•R«ALLmxea eOM MDoIAta Srlml. RPE AUGNMClf GUIDE RM ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 91 9,61 0,1051 FIRM NC LICENSE NUMBER C-4222 REVISION HISTORY REV SCALE: M DESCRIPTION I DATE I BY 1 ADDRESS NCDEO FLM COMMENTS 1/122018 FLM 2 ADDRESS NCOEO COMMENTS 1232018 FLM 3 ADDRESSFCPU 2J122018 FLM ORIGINAL PLAN SIZE: 20" X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGI 'ML —ING 0 i IE IT a NOT t INCH ON THIS SHEET, ADJUST YOUR SEAL£ ACCORDNGLY CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 �,>oeve Crosswind 5f,%lopment DATE: 12-07-2017 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 17022 DETAILS C-16 SHEET 16 OF 17 All T- - --- ------ ---- I -Z -" FRANKLIN COUNTY PUBLIC UTILITIES CONCRETE W-6 THRUST BLOCKING ------------ FRANKLIN COUNTY PUBLIC _UTILITIES 41TANDARMULT D PU 7w, IIIIIIIIIIANCH 111111411061111 ALL NOT BE REPROWGED M WHOLE OR N REWWSSION OF FLA ENGMEEFUIG. ML. I-ILI' (JAIL FRANKLINCOUNTYPUBLIC UTILITIES .... . ... ........ . W-2 VALVE ASSEMBLY 1 -"J FRANKLIN COUNTY PUBLIC UJILIULS 'bhIWINDI . COLLAR W-7 D E T AIL SECTIN D -D w tR11k e0 us, COY[ R 70 Ll6, WA R 9-9 =I" A -A, FRANKLIN COUNTY PUBLIC UTILITIES 3/4' AND ? WATER METER BOX DETAL REV 4T Sl ADDRESS NCDEQ DATE 1/1212018 FLM COMMENTS SCALE: ADDRESS NCDEO DESIGNED BY �R APPROVED BY ADDRESS FCPLI 3 211212018 FILM COMMENTS TITANII COUNTY PUBLIC UtItIfIrS g VALVE MARKER POST DETAIL 1-.INTY PUBLIC. UTILITIES 911 WATER MAN TAPPING SLEEVE W-3 TRENCH DETAIL All T- - --- ------ ---- I -Z -" FRANKLIN COUNTY PUBLIC UTILITIES CONCRETE W-6 THRUST BLOCKING ------------ FRANKLIN COUNTY PUBLIC _UTILITIES 41TANDARMULT D PU 7w, IIIIIIIIIIANCH 111111411061111 ALL NOT BE REPROWGED M WHOLE OR N REWWSSION OF FLA ENGMEEFUIG. ML. I-ILI' (JAIL FRANKLINCOUNTYPUBLIC UTILITIES .... . ... ........ . W-2 VALVE ASSEMBLY 1 -"J FRANKLIN COUNTY PUBLIC UJILIULS 'bhIWINDI . COLLAR W-7 D E T AIL SECTIN D -D w tR11k e0 us, COY[ R 70 Ll6, WA R 9-9 =I" A -A, FRANKLIN COUNTY PUBLIC UTILITIES 3/4' AND ? WATER METER BOX DETAL FRANKLIN COUNTY PUBLIC UTILITIES oY VERTICAL W-1 SENDS IAIooIe REV 4T Sl ADDRESS NCDEQ DATE 1/1212018 FLM COMMENTS SCALE: ADDRESS NCDEO DESIGNED BY �R APPROVED BY ADDRESS FCPLI 3 211212018 FILM COMMENTS VALVE MARKER POST DETAIL 1-.INTY PUBLIC. UTILITIES F` 16IIEF.6 TAPPING SLEEVE W-3 AND VALVE ASSEMBLY FRANKLIN COUNTY PUBLIC UTILITIES oY VERTICAL W-1 SENDS IAIooIe REV 4T Sl ADDRESS NCDEQ DATE 1/1212018 FLM COMMENTS SCALE: ADDRESS NCDEO DESIGNED BY �R APPROVED BY ADDRESS FCPLI 3 211212018 FILM COMMENTS F` 16IIEF.6 FRANKLIN COUNTY PUBLIC UTILITIES FIRE SERVICE _s Ill VAULT (Scm VARIES) JI ASS I`Y FRANKLIN COUNTY PUBLIC UTILITIES 7DMWYJaY r BLOBLOWOFFASSBABLY UIERIIIIIIANBIT) FRANKLIN COUNTY PUBLIC UTILITIES FAl 01 3` - Ir REDUCED W Ta PRESSURE BACII PREVENTER VAN : P�t REV 4T ADDRESS NCDEQ DATE 1/1212018 FLM COMMENTS SCALE: ADDRESS NCDEO DESIGNED BY �R APPROVED BY ADDRESS FCPLI 3 211212018 FILM COMMENTS -- -- --- -------- - LEN L—z L J Top slEc7lo 't =nF-- ES �75 =r=XX-- I VEWI SALVE all r- FRAIII COUNTY PUBLIC UTILITES AL RESIDENTIAL ICNINECTION ENGINEERING POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIR. INC LICENSE NUMBER C-4222 REVISION HISTORY REV DESCRIPTION DATE BY ADDRESS NCDEQ DATE 1/1212018 FLM COMMENTS SCALE: ADDRESS NCDEO DESIGNED BY COMMENTSEQ 1/23/2018 FILM APPROVED BY ADDRESS FCPLI 3 211212018 FILM COMMENTS ORIGINAL PLAN SIZE: 24"X 36" ISSUED FOR PERMITTING DO NOT USE FOR CONSTRUCTION SCALE ADJUSTMENT THIS MR IS 1 INCH IN LENGTH ONORIGS­ DMINING 0 1. I I IF It IS NOT I INCH ON THIS SH- ADJUST YOUR I -COR-Y CONSTRUCTION PLANS CRAWFORD TOWNES NC HWY 56 FRANKLINTON, NC 27525 DETAILS C-17 SHEET 17 OF 17 <Crosswind ovetopment DATE 12-07-2017 SCALE: ASSHOWN DESIGNED BY FILM APPROVED BY FLM PROJECT NO. ,17022IF J DETAILS C-17 SHEET 17 OF 17 qk��, k &- \ �� , Vy Y 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or X No F1 Yes ❑ habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act 0 Yes E] No impacts? 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? USFWS website https://www,fws.gov/raleigh/species/cntylist/tanklin.html. NC Natural Heritage Program GIS data updated October 2017. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ❑X No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? hftp://www.habitat.noaa/gov/protection/efh/habitatmapper.html 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation ❑ Yes ❑X No status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? HPOWEB Map Service http:/Igis.nedcr.gov/hpoweb/. National Register of Historic Places http://www.nps.gov/nr/researchl. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain? ❑Yes ❑X No 8b. If yes, explain how project meets FEMA requirements: 8c. What source(s) did you use to make the floodplain determination? Franklin County GIS floodplain mapping, North Carolina Floodplain Mapping Program http://www.ncfloodmaps.com Applicant/Agent's Signature Applicant/Agent's Printed Name Date (Agent's signature is valid only if an authorization letter from the applicant isprovided.) Page 10 of 10