Loading...
HomeMy WebLinkAbout20180142 Ver 1_More Info Received_20180227Strickland, Bev From: Justin Church <justin@brec.biz> Sent: Tuesday, February 27, 2018 3:13 PM To: Leslie, Andrea J Cc: Homewood, Sue; Derek Goddard; Elliott, William A SAW Subject: Re: [External] Re: CC Hays Stream Restoration - questions leternal email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to port Spa Andrea, You can see the riffle cross sections on sheets C101 and C104; however, the bankfull bench is a little hard to pick out at the drawing scale. To clairfy, UT#1 has a bankfull bench width of 3' on stream left and stream right. UT#2 has an average floodplain width of 38' with the 14' channel meandering through that width. That leaves an average 12' bankfull bench for UT#2. These benches show up in the contours of the grading plans for both streams. Let me know if I can answer any further questions. Thanks /j c On Tue, Feb 27, 2018 at 1:26 PM, Leslie, Andrea J <andrea.leslie@ncwildlife.org> wrote: Can you tell me where in the plans the bankfull bench is depicted? The only cross-section I see is for the ford. Andrea Andrea Leslie Mountain Habitat Conservation Coordinator NC Wildlife Resources Commission 645 Fish Hatchery Rd., Building B Marion, NC 28752 828-803-6054 (office) 828-400-4223 (cell) 1 www.ncwildlife.org Get NC Wildlife Update delivered to your inbox from the N.C. Wildlife Resources Commission. Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. From: Justin Church [mailto:iustin@brec.biz] Sent: Friday, February 23, 2018 10:02 AM To: Homewood, Sue <sue.homewood@ncdenr.gov> Cc: Derek Goddard <derek@brec.biz>; Leslie, Andrea J <andrea.leslie@ncwildlife.org>; Elliott, William A SAW <William.A.Elliott@usace.army.mil> Subject: Re: [External] Re: CC Hays Stream Restoration - questions External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to Report Spam. We can pump on that one and work in the dry. Let me know if I can provide additional information. Thanks. /j c On Fri, Feb 23, 2018 at 9:54 AM, Homewood, Sue <sue.homewoodsue.homewood@ncdenrgov> wrote: Justin/Derek, Could you please provide a response or additional information regarding Andrea's comment about working in the dry on UT#2, I have the same concern/comment. Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood a-ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Derek Goddard [mailto:derek@brec.biz] Sent: Thursday, February 15, 2018 1:32 PM To: Homewood, Sue <sue.homewood@ncdenr.gov>; Leslie, Andrea J <andrea.leslie@ncwildlife.org>; Elliott, William A SAW <William.A.Elliott@usace.army.mil> Cc: Justin Church <justin@brec.biz> Subject: [External] Re: CC Hays Stream Restoration - questions External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to Report Spam. Hi Andrea, I have answered your questions below. Let me know if you have any other questions. Thanks On Thu, Feb 15, 2018 at 1:09 PM, Justin Church <justin@brec.biz> wrote: ---------- Forwarded message From: Leslie, Andrea J <andrea.leslie@ncwildlife.org> Date: Thu, Feb 15, 2018 at 1:04 PM Subject: CC Hays Stream Restoration - questions To: " ustin@brec.biz" <justin@brec.biz> Cc: "Homewood, Sue" <sue.homewood@ncdenr.gov>, "Elliott, William A CIV USARMY CESAW (US)" <William.A.Elliott(@usace.armv.mil> Justin, I have reviewed the PCN and plans for the CC Hays Stream Restoration project and I have a few questions/comments: • The application states that the "stream is too large to practically pump around". By my rough estimate, the larger stream has a drainage area of 0.6 sq mi, which seems small enough to easily pump around. Given the amount of instream work to be done with the large number of structures, it may be especially important to do this work in the dry. • We are concerned with the highly dense and regular sequence of instream structures on this project. They may hinder the stream from self-adjusting, possibly causing instability over time. • How wide will the planted riparian buffer within the fenced area be, per side? A minimum of 10' and in some place significantly more. • What is temporary seed for the riparian area? Rye Grain or Browntop Millet depending on the season • Will there be a bankfull bench? Can you provide stream cross-section information in your plan set? Yes, it is shown in the plans Thank you, Andrea Andrea Leslie Mountain Habitat Conservation Coordinator NC Wildlife Resources Commission 645 Fish Hatchery Rd., Building B Marion, NC 28752 828-803-6054 (office) 828-400-4223 (cell) www.ncwildlife.or Get NC Wildlife Update delivered to your inbox from the N.C. Wildlife Resources Commission. Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. Justin Church, PE, CFM Principal Engineer BREC, P.A. 126 Executive Drive, Suite 220 Wilkesboro, NC 28697 (o) 336.844.4088 R?R_773.6543 http://brec.biz Derek Goddard, PLS, GISP BREC, P.A. 126 Executive Drive, Suite 220 Wilkesboro, NC 28697 828.265.4425 336.844.4088 828.964.9349 Cell www.brec.biz derek@brec.biz Confidentiality Notice: This E -Mail transmission (and/or the documents accompanying it (Attached or uploaded to the BREC, P.A. server) may contain information belonging to the sender and/or intended recipient which is confidential, privileged and/or exempt from disclosure under applicable law. The information is intended only for the use of the individual(s) or entity named above. If you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this E - Mail transmission in error, please immediately notify us by return E -Mail or telephone to arrange for return of its contents including any documents. Justin Church, PE, CFM Principal Engineer BREC, P.A. 126 Executive Drive. Suite 220 Wilkesboro, NC 28697 (o) 336.844.4088 (c) 828.773.6543 http://brec.biz Justin Church, PE, CFM Principal Engineer BREC, P.A. 126 Executive Drive, Suite 220 Wilkesboro, NC 28697 (o) 336.844.4088 (c) 828.773.6543 http://brec.biz