February 16, 2018
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
Mr. Gary L. Page, County Manager R8CP/
Wilkes County ����������
110 North Street FEB
Wilkesboro, NC 28697 2 6 2018
e er Resource
41
Subject: Compliance Evaluation Inspection g Se s
Permittee: Wilkes County - ction
Facility: Wilkes County Airport Wastewater Collection System
Permit # WQCSD0241
Wilkes County
Dear Mr Page:
Gary Hudson of the Winston-Salem Regional Office of the NC Division of Water
Resources (DWR or the Division) conducted a compliance evaluation inspection (CEI) of
the Wilkes County Airport wastewater collection system (WWCS) on January 11, 2018.
The assistance and cooperation from Mr. Dustin Caudill was greatly appreciated. An
inspection checklist is attached for your records and inspection findings are summarized
below.
Site/System Review
2 The following system components were inspected -
a. The entire collection system was observed and found to be very well maintained and
operated. No concerns or discrepancies were noted during this inspection.
3. As you are aware, owners of deemed permitted collection systems must comply with all
rules listed under NC Administrative Code 15A NCAC 02T.0400, et seq. Your compliance
status with each of these rules is summarized below:
a 15A NCAC 02T .0403(a)(1): Requires that the system be effectively maintained and
operated at all times to prevent discharge to land or surface waters and any
contravention of ground or surface water standards
Observations: No overflows or bypasses from the system have been reported to date
and you were otherwise found to be substantially compliant with this requirement
Compliance Status: Compliant.
b 15A NCAC 02T .0403(a)(2): Requires that a map of the wastewater collection system
be developed and actively maintained
'5'^Nothing Compares'-'-_,_
State
om pares' -_,,,-
State of North Carolina I Environmental Quality
450 W Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105
Phone 336-776-98001 FAX* 336-776-9797
Observations: Mr Caudill had a system map at the time of the inspection There
appear to have been no updates to the map but Mr Caudill said he was unaware of any
changes in the system that would require an update The map shows the layout of the
sewer lines and locations of manholes
Compliance Status: Compliant.
c 15A NCAC 02T .0403(a)(3): Requires that an operation and maintenance (O&M) plan
be developed and implemented, which includes pump station inspection frequency,
preventative maintenance schedule, spare parts inventory and overflow response
Observations: Mr Caudill presented for inspection a written plan that included brief
narratives about operation/maintenance, grease education and spills.
Compliance Status: Compliant.
d 15A NCAC 02T .0403(a)(4): Requires that the permittee or its representative inspect
pump stations that are not connected to a telemetry system (i e., remote alarm system)
every day (i e., 365 days per year) and pump stations that are connected to a telemetry
system at least once per week
Observations: This condition does not apply because there are currently no pump
stations within the system
Compliance Status: Not Applicable.
e 15A NCAC 02T .0403(a)(5l.: Requires that the permittee or its representative inspect
high-priority sewers (HPS — as defined in 15A NCAC 02T 0402(2)) at least once every
six -months and document the inspections
Observations: Mr Caudill inspects the entire system daily, and there are no high
priority lines in this system A logbook is being kept to record all inspections
Compliance Status: Compliant.
f 15A NCAC 02T .0403(a)(6): Requires that the permittee or its representative conduct
a general observation of the entire wastewater collection system at least once per year
Observations: A logbook is being kept to record all inspections
Compliance Status: Compliant.
g 15A NCAC 02T .0403(a)(7): Requires that overflows and bypasses from the system be
reported to the Division's Winston-Salem regional office in accordance with 15A NCAC
02B 0506(a), and that public notice must be provided as required by G S 143-215.1 C
Observations: This condition does not currently apply because there have been no
spills or bypasses of the system reported in the past two years
Compliance Status: Compliant.
h. 15A NCAC 02T .0403(a)(8)(A&C or B&C): Requires that a grease control program be
developed and implemented as follows -
1 For privately owned collection systems the grease control program shall include at
least bi-annual distribution of grease education materials to users of the collection
system by the permittee or its representative
2. Grease education materials shall be distributed more often than required above if
necessary to prevent grease -related sanitary sewer overflows
Observations: Mr Caudill distributes grease educational flyers bi-annually to all
businesses at the airport.
Compliance Status: Compliant,
i 15A NCAC 02T .0403(a)(9): Requires that right-of-ways (ROW) and easements be
maintained in the full easement width for personnel and equipment accessibility
Observations: Mr. Caudill keeps records of all maintenance performed in a logbook
Compliance Status: Compliant.
j. 15A NCAC 02T .0403(a)(10): Requires that documentation be kept for all activities you
undertake to comply with the requirements of 15A NCAC 02T 0403, subparagraphs
(a)(1) through (a)(9), for a minimum of three years, with the exception of the map, which
shall be maintained for the life of the system
Observations: Mr. Caudill does an excellent fob keeping records as required by this
administrative code
Compliance Status: Compliant.
4 Mr Caudill has done a very good fob of developing and implementing the WWCS program.
The Division thanks Mr Caudill and his staff for their efforts in managing its collection system
and for their part in safeguarding the natural resources of North Carolina for future
generations If you have any questions regarding the inspection or this letter, please call
Gary Hudson or me at (336) 776-9800. Thank you for your cooperation in this matter.
Sincerely,
Sherri V Knight, P.E.
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
cc: WSRO — SWP
Central Files
PERCS Unit
Compliance Inspection Report
Permit WQCSD0241 Effective 03/01/00 Expiration
SOC Effective Expiration
County Wilkes
Region Winston-Salem
Contact Person David Prevette Title
Directions to Facility
System Classifications
Primary ORC
Secondary ORC(s)
On -Site Representative(s)
Related Permits
Inspection Date 01/11/2018
Primary Inspector Gary Hudson
Secondary Inspector(s)
Entry Time 09 OOAM
Certification
Owner Wilkes County Airport
Facility Wilkes County Airport Collection System
Phone 336-651-7300
Phone
Exit Time 10 OOAM
Phone 336-776-9694
Reason for Inspection Routine Inspection Type Collection System Inspect Non Sampling
Permit Inspection Type Deemed permitted collection system management and operation
Facility Status Compliant F� Not Compliant
Question Areas
Miscellaneous Questions Performance Standards Operation & Mamt Reqmts
Records Momtonng & Rptmg Reqmts Inspections
Pump Station
(See attachment summary)
Page 1
Permit WQCSD0241 Owner - Facility Wilkes County Airport
Inspection Date 01/11/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Inspection Summary
Page 2
Permit WQCSDO241 Owner - Facility Wilkes County Airport
Inspection Date 01/11/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Performance Standards
Is Public Education Program for grease established and documented?
What educational tools are used?
Is Sewer Use Ordinance/Legal Authority available?
Does it appear that the Sewer Use Ordinance is enforced?
Is Grease Trap Ordinance available?
Is Septic Tank Ordinance available (as applicable, I e annexation)
List enforcement actions by permittee, if any, in the last 12 months
Has an acceptable Capital Improvement Plan (CIP) been implemented?
Does CIP address short term needs and long term \"master plan\" concepts?
Does CIP cover three to five year period?
Does CIP include Goal Statement?
Does CIP include description of protect area?
Does CIP include description of existing facilities?
Does CIP include known deficiencies?
Does CIP include forecasted future needs?
Is CIP designated only for wastewater collection and treatment?
Approximate capital improvement budget for collection system?
Total annual revenue for wastewater collection and treatment?
CIP Comments
Is system free of known points of bypass?
If no, describe type of bypass and location
Is a 24-hour notification sign posted at ALL pump stations?
# Does the sign include
Instructions for notification?
Pump station identifier?
24-hour contact numbers
If no, list deficient pump stations
# Do ALL pump stations have an "auto polling" feature/SCADA?
Number of pump stations
Number of pump stations that have SCADA
Number of pump stations that have simple telemetry
Yes No NA NE
N ❑ 1:111
❑❑■❑
❑ ❑ N 1
❑❑■❑
❑ ❑ M❑
❑11011
❑❑■❑
❑❑■❑
❑❑■❑
1:11:1 NO
■❑❑❑
0
0
0
❑ ❑ N ❑
1:10 M ❑
1:111 M ❑
❑ ❑ M ❑
Page 3
IN
Permit WQCSDO241 Owner - Facility Wilkes County Airport
Inspection Date 01/11/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
Number of pump stations that have only audible and visual alarms c
Number of pump stations that do not meet permit requirements 0
# Does the permittee have a root control program? ❑ ❑ ❑
# If yes, date Implemented?
Describe
Comment _
Inspections
Yes No NA NE
Are maintenance records for sewer lines available?
M ❑ ❑ ❑
Are records available that document pump station Inspections?
❑ ❑ M ❑
Are SCADA or telemetry equipped pump stations Inspected at least once a week?
❑ ❑ 0 ❑
Are non-SCADA/telemetry equipped pump stations inspected every day?
❑ ❑ M ❑
Are records available that document citizen complaints?
0 ❑ ❑ ❑
# Do you have a system to conduct an annual observation cf entire system?
0 ❑ ❑ ❑
# Has there been an observation of remote areas in the last year?
0 ❑ ❑ ❑
Are records available that document Inspections of high-pncnty lines?
❑ ❑ ❑
Has there been visual Inspections of high-prionty lines in last six months?
❑ ❑ 0 ❑
Comment
Operation & Maintenance Requirements Yes No NA NE
Are all log books available? ❑ ❑ ❑
Does supervisor review all log books on a regular basis? ❑ ❑ ❑
Does the supervisor have plans to address documented shcrt-term problem areas? ❑ ❑ M ❑
What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas?
Are maintenance records for equipment available?
M ❑ ❑ ❑
Is a schedule maintained for testing emergency/standby equipment?
❑ ❑ 0 ❑
What is the schedule for testing emergency/standby equipment?
Do pump station logs include
Inside and outside cleaning and debris removal?
❑ ❑ ❑
Inspecting and exercising all valves?
❑ ❑ M ❑
Inspecting and lubricating pumps and other equipment?
❑ ❑ ❑
Inspecting alarms, telemetry and auxiliary equipment?
❑ ❑ ❑
Is there at least one spare pump for each pump station w/o pump reliability?
❑ ❑ ❑
Are maintenance records for right-of-ways available?
❑ ❑ ❑
Are nght-of-ways currently accessible in the event of an emergency?
0 ❑ ❑ ❑
Are system cleaning records available?
0 ❑ ❑ ❑
Has at least 10% of system been cleaned annually?
❑ ❑ M ❑
Page 4
g a6ed
❑ ■ ❑ ❑ ealgeliene uogeoggnd;o looad pue saoilou oggnd ajV
❑ N ❑ ❑ ealgepene slsq uognqulslp pue seseelai ssaid paimbai to saidoo aiV
3N VN ON SOX sluewaim e'd uilio as pue bUIJOIIUOIN
juawwo0
❑ ■ ❑ ❑ eliuuad jiegl to Adoo a aneq ealliwied ay; scop #
apnlow dew ayl saoO
❑ ❑ ❑ ■ e,algeiiene walsAs aql jo dew a sl
❑ ■ ❑ ❑ eueid uoiloe ampa uoo a ajayl si 's9A 11
❑ ❑ N ❑ euoileool awes le (sgluow Zl w ajow jo Z) smoipano poleadaj aleoipuw spiooal Ilids oO
❑ 0 ❑ ❑ e,algeliene plogsajgl algeliodai ay; japun aie jell sOSS;o spiooaj a1V
❑ ■ ❑ ❑ e,algeliene slweldwoo pue silids 'sOSS lie ;o spiooai alenbape oiV
3N VN ON SUX spJ009Z1
}uawwoo
■ 1111 ❑
dew ay; of pappe aq of peau leyl suoisuapxa pue suolleoylpow Aue lsll
❑ ❑ ❑ 0
e,alaldwoo si lueoiad legm 'ou lI
❑ ■ ❑ ❑
Alioedeo pue suoilels dwnd
❑ ❑ ❑ ■
sdel auivas;o jagwnN
❑ ❑ ❑ ■
aft adid alewixaddV
❑ ❑ ❑ ■
u0113aiip nnold
❑ ❑ ❑ ■
uogeool adid
❑ ❑ ❑ .
sleualew adld
❑ ❑ ❑ .
sezis edid
apnlow dew ayl saoO
❑ ❑ ❑ ■ e,algeiiene walsAs aql jo dew a sl
❑ ■ ❑ ❑ eueid uoiloe ampa uoo a ajayl si 's9A 11
❑ ❑ N ❑ euoileool awes le (sgluow Zl w ajow jo Z) smoipano poleadaj aleoipuw spiooal Ilids oO
❑ 0 ❑ ❑ e,algeliene plogsajgl algeliodai ay; japun aie jell sOSS;o spiooaj a1V
❑ ■ ❑ ❑ e,algeliene slweldwoo pue silids 'sOSS lie ;o spiooai alenbape oiV
3N VN ON SUX spJ009Z1
}uawwoo
■ 1111 ❑
ealenbape /joluem slied meds eqj sl
❑ ❑ ❑ 0
e lauumed Ile jol aigeliene ueid uoiloV asuodsaM 1lidS a sl
❑ ❑ ❑ ■
luawssasse Ipds/moUJano-;sod
❑ ❑ ❑ ■
sleualew dnueep pue uoilelwes alis
■ ❑ ❑ ❑
spun; [buoBjewe to aoinoe
❑ ❑ ❑ .
siaaw6us jo/pue 'sioloeiluoo 'smajo uoilonilsuoo of sseooV
❑ ❑ ❑ 0
luawdmba 6wuealo of ssaooV
❑ ❑ ❑ N
/-joluanw sped meds pue lsq luawdmba
❑ ❑ ❑ ■
owil asuodso-d
❑ ❑ ❑ M
sjegwnu loeluoo inoq-yZ
opnloul ueid all saop
❑ ❑ ❑ .
e,algeliene ueid uoiloV asuodsa�l IlidS a sl
e,sgluow Zl lxau all w 6wuealo jo; palnpagos aie seam, leyM
eugnoa iis'A Jo; uoseatl
6uwldweS uoN pedsul walsAS uogoalloO adAi. uoijoadsul 910Z/66/bo awG uopedsul
liodjiVf4unoOseNIM Appoed -jaumo LtZOOSOI)M PwJad
N
51
Permit WQCSD0241 Owner - Facility Wilkes County Airport
Inspection Date 01/11/2018 Inspection Type Collection System Inspect Non Sampling Reason for Visit Routine
# Is an annual report being prepared in accordance with G S 143-215 1 C?
# Is permittee compliant with all compliance schedules in the permits
If no, which one(s)'?
Comment
❑❑■❑
❑❑ME]